AL-WAHA PETROCHEMICAL COMPANY Doc. No.: WAH-TRS-FMS-RBS-092


TECHNICAL & RELIABILITY SERVICES DEPARTMENT Revision No.: 92
Equipment-Piping Thickness Measurement Record Date: MAY 2014

REPORT NO: INS/PLANTXXX/RPTXXX/Year
Page 1 of 2

PLANT: PDH PP UTILITY
Tag No.:

Description:

Criticality: SHE

Non-SHE




Service:


Insulation Type: Hot


Cold


Coating:


Corrosion Allowance:



X

Reason for Inspection: ( )Regular Inspection ( )MOC ( )Repair ( )Shut down( )Base Survey
Drawing / Sketch (See Page 2)
TML NO.
ORIGINAL
THICK (mm)
AS FOUND THICKNESS READING (mm) REMARKS
T B N W S E Other Location
SHELL
A MIN 6.04 MAX 6.69
B MIN 6.24 MAX 6.69
C MIN 6.25 MAX 6.35
D MIN 6.2 MAX 6.8
E MIN 6.25 MAX 6.35
F MIN 6.24 MAX 6.85
G MIN 6.2 MAX 6.88
H MIN 6 MAX 6.45
I MIN 5.57 MAX 6.89
J MIN 5.59 MAX 6.35

TOP MIN 5.53 MAX 6.86

BOT MIN 5.6 MAX 6.29

NOZZLE 1 MIN 4.03 MAX 4.18
2 MIN 4.11 MAX 4.7
3 MIN 3.62 MAX 4.38

A) UT Meter SL No: DMS 2 / 024YNH
B) Calibration Date 11/6/2013
C) Probe & Frequency 5MHZ
D) Equipment Material CARBON STEEL
E) Surface Temp during Inspection 40C
F) Reference Procedure used ASME VIII
Date : 16/06/2014
Signature





Name M.EMYZULHAZIM VAJID M. ABDULKAREEM ABDULLAH A. AL-QARNI
Plant Inspector/ Contractors Engineer Verified by
SK inspection Representative
SAHARA Inspector
Stationary & Equipment
Engineer
WAN/PP/92/2014





AL-WAHA PETROCHEMICAL COMPANY Doc. No.: WAH-TRS-FMS-RBS-092
TECHNICAL & RELIABILITY SERVICES DEPARTMENT Revision No.: 92
Equipment-Piping Thickness Measurement Record Date: MAY 2014

REPORT NO: INS/PLANTXXX/RPTXXX/Year

Page 2 of 2

Plant : WORKSHOP
Equip. #
Description :

Date : 16/06/2014