You are on page 1of 62

ISSUE

Training About DDF Survey


1.0

Auxiliary equipment Product Line
JUNE, 2005
Shu Wen Hua



2


Contents
1.DDF(Digital Distribution Frame) Product Profile
2.Introduction to Huawei DDF Products
Particular Description refer to Appendix
3.Huawei DDF Product survey



3
DDF Product Profile
1.DDF products in traditional communication network
SDH
D
W
D
M
D
W
D
M
SDH
SDH
SDH
SDH
SDH
SDH
ODF
ODF
DWDM
ODF
ODF
ODF
ATM875
Optix W32
C&C08
ODF
DDF
EAST8000
DDF
ODF
DDF
ODF
PDH
DDF
DDF
DDF
CATV ODF
ODF
SDH
C&C08
OptiX
155/622/2500/10G
OptiX W32
OptiX
METRO
DDF
DDF
HONET
METRO
IP
Copper cable
C&C08
C&C08
HONET
HONET
OptiX
155/622/2500/10G
OptiX
155/622/2500/10G
OptiX
155/622/2500/10G
OptiX
155/622/2500/10G
MDF
MDF
MDF
MDF
MDF



4

DDF Product Profile
2. Technical Terms of DDF Products
Digital
Distribution
Frame
DDF
DDF is a distribution and connection
device between digital multiplex, and
between a digital multiplex device
and a program-controlled exchange
device or a non-voice service device.
The loops in DDF formed by the
branch circuits of receiving and
transmitting ( also named as loop,
system or E1)
2M/bit
Loop



5

Digital unit
Adopting balanced cable and the
connector unit with 120
characteristic impedance.
DDF Product Profile
120/120
Balanced
connector
unit
75/75
Unbalanced
connector
unit
Functional assemblies
composed by numbers of E1
(also called unit).
Adopting RF coaxial cable and the
connector unit with 75
characteristic impedance.



6

75/120
Impedance
transforming
connector unit
Transform the connecting mode of RF
coaxial cables with 75 characteristic
impedance to the mode of balanced
cables with 120 characteristic
impedance.
DDF Product Profile
Impedance
matching
The internal resistance of signal source is
the same with characteristic impedance of
the transmission line in quantity and phase;
or characteristic impedance of the
transmission line is the same with
impedance of load in quantity and phase;
which means respectively input or output
impedance matching of transmission line.



7

1.6/5.6 RF
coaxial
connector


In fact, the RF coaxial connector is also a coaxial
transmission line, in which there are separable
electric contact unit, connecting unit and other
device for installation and termination.








DDF Product Profile
BNC RF coaxial
connector





8


Contents
1.DDF Product Description

2.Introduction to Huawei DDF Products
Particular Description refer to Appendix

3. Huawei DDF Product survey



9
Huawei DDF Product

75DDF
MPX286-R
MPX272-FM600
MPX286-DR
120DDF
MPX272-F
MPX272-R
MPX272-FM800
MPX272-CM600
MPX272-CM800
Open-
type
frame
Enclosed
-type
cabinet



10

75DDF
MPX272-F1M600/
F2M600/F3M600
MPX272-F1/F2/F3
MPX272-F4/F5/F6
MPX272-F1M800/
F2M800/F3M800
Open-
type
frame
Huawei DDF Product
19 standard double-
side frame
19 standard single-side
frame
Double-side cabling
management
800 width frame
Double-side cabling
management
600 width frame



11

75ohmDDF
MPX272-C1M600/C2M600/C3M600
MPX272-C1M800/C2M800/C3M800
Enclosed
-type
cabinet
Huawei DDF Product
Double-side cabling
management
600 width cabinet
Double-side cabling
management
800 width cabinet



12
Huawei DDF Product

MPX286-R
MPX286-DR
120ohmDDF
Open-
type
frame
Single-side frame
Double-side frame



13


Contents
1.DDF Product Description
2.Introduction to Huawei DDF Products
Particular Description refer to Appendix
3. Huawei DDF Product survey



14

Engineering
surveys
Surveys of Huawei DDF Products
Net
height of
room &
height of
antistatic
floor
Impedance
of DDF
connector
Capacity
expansion
project
coaxial
connector
Net height of room &height of room;
Height of raised floor;
length of grounding wire;
Dimension of product-frame/cabinet
(main height)
The outer diameter of cable sheath and
insulating layer should be known if the cable
model is unknown; the connector is male:
connected the coaxial cable with inner
conductor by welding and with external
conductor by crimping;
Generally, the model of transmission side
differs from that of the exchange side;
Needed information , such as manufacture ,model
and specifications of existing DDF;
Ensure the equipment compatible and in accordance
with the existing ones ;
75 Or
120



15
Surveys of Huawei DDF Products




75-2-1



75-2-2
Structure of coaxial cable
Unit Jacket
Extennal Insulation Inner Conductor
Conductor
(Braid Shield)
Ground Wire Trunk cable
Unit Jacket
First Braid Shield
Sencond
Braid
Shield Insulation
Inner
Conductor
Ground Wire Trunk cable



16
Type of 75 Ohm Trunk Cable
Type of 75 Ohm
Trunk Cable
Solid Conductor- (mm) Insulation-(mm) J acket - (mm)
SYV-75-2-1 0.34 2.10 3.40
SYV-75-2-2 0.34 2.10 4.10
SYV-75-3-2 0.50 3.00 6.50
SYV-75-4-2 0.61 3.80 7.50
SFYZ75-2-1 0.25 1.45 2.57
SFYV75-2-1 0.25 1.45 2.6-2.8
SYFVZ-75-1-1 0.25 1.20 2.20
SYFVZP-75-1-1 0.25 1.20 2.20



17
Surveys of Huawei DDF Products
Structure of coaxial connector

Identifier



18
Surveys of Huawei DDF Products
Specifications of coaxial connector

Coaxial
Connector
1.6/5.6
1.6/5.6
1.6/5.6
1.6/5.6

1.5/6.5
1.5/6.5
1.5/6.5
1.6/5.6
1.6/5.6
1.5/6.5
Trunk Cable
Non-standard
Diamet-
er
Diamet-
er
Diamet-
er
Diamet-
er
Diamet-
er



19
Specification Technique of SYFVZ-75-1-1 E1 Cable
Solid Conductor: 0.25 mm
Insulation: 1.20 mm
Shield: 1.8 mm
Material: Polyvinyl Chloride (PVC)
Material: Polyethylene (PE)
Jacket: 2.2 mm
2.2 mm
Material: Bare Copper
Material: Single Plain Bare Copper Braid



20
Specification of JIS 2.5C-2V Coaxial Cable
Inner Conductor: 0.4 mm
Sheath: 4.0mm
Insulation: 2.4 mm
Outer Conductor: 3.0mm
Material: Black Polyvinyl Chloride(PVC)
Material: Polyethylene (PE)
Material: Copper Braid
4.0 mm
Material: Copper Wire



21
Specification Technique of 2.5C-2V E1 Cable


S: Strand inner conductor
CS: Copper-clad steel wire inner conductor
V: Single braid outer conductor
W: Double braid outer conductor
2 : PE Insulation dielectric core
C :Characteristic impedance 75 ohm
D :Characteristic impedance 50 ohm
3 :Approx. diameter of dielectric core
So SYFVZ-75-1-1 can be compared to 1.2C-2V



22
Specification Technique of SYFVZP-75-1-1 E1 Cable
Product Code Descriptions Conductor (Dia) Insulation (Dia) Shield (Dia) Jacket (Dia)
2.5C-2V-04/96 2.5C-2V 0.4 mm BC 2.4 mm PE 0.12 mm x 96 BC 4.0 mm PVC
3C-2V-05/48 3C-2V 0.5 mm BC 3.0 mm PE 0.12 mm x 48 BC 5.0 mm PVC
3C-2V-05/96 3C-2V 0.5 mm BC 3.0 mm PE 0.12 mm x 96 BC 5.0 mm PVC
3C-2V-05/112 3C-2V 0.5 mm BC 3.0 mm PE 0.12 mm x112 BC 5.4 mm PVC
3C-2V-06/64 3C-2V 0.6 mm BC 3.0 mm PE 0.12 mm x 64 BC 5.0 mm PVC
3C-2V-06/96 3C-2V 0.6 mm BC 2.6 mm PE 0.12 mm x 96 BC 5.2 mm PVC
5C-2V-07/80 5C-2V 0.7 mm BC 4.5 mm PE 0.12 mm x 80 BC 6.9 mm PVC
5C-2V-07/96 5C-2V 0.7 mm BC 4.5 mm PE 0.12 mm x 96 BC 6.9 mm PVC
5C-2V-07/80 5C-2V 0.8 mm BC 4.5 mm PE 0.12 mm x 80 BC 6.9 mm PVC
5C-2V-07/96 5C-2V 0.8 mm BC 4.5 mm PE 0.12 mm x 96 BC 6.9 mm PVC
ISSUE

Training About ODF Survey
1.0

Auxiliary Equipment Product Line
JUNE,2005
WEN HUA SHU




24
Contents
1. ODF (Optical-fiber Distribution Frame)
Product Profile
2. Introduction to Huawei ODF Product
(Particular Description refer to Appendix)
3. Surveys of Huawei ODF Product




25
ODF Product Profile
EAST8000
1. ODF in Traditional Communication Network



26
2. Technical terms in ODF
Patch cord( Fiber jumper): a optical cable with adapter on both ends;
Tail fiber (Pigtail fiber) a optical cable with adapter on one end;
Adapter: is the devices that make optical connection between tail fibers and patch
cords. FC/PC adapters are usually used in ODF, SC/PC adapters are used in
some ODF.
ODF Product Profile
Patch cord SC adapter FC adapter



27
ODF Product Profile (Function)
3Introduce to functions of ODF product
. Fixing and protection function
Entry unit of
optical-fibers in C
series cabinet
Entry unit of
optical-fibers in R
series cabinet



28
Splicing function (Splice
tray)
ODF Product Profile (Function)

Patch Function
(Patch panel)



29
ODF Product Profile
4. Protection function for fiber-core and bare fiber
5.Fiber storage function
Fiber-core protection
(Coiled protection sleeve)
Bare fiber protection
(Protection sleeve)



30
ODF Product Profile
5Connection of optical-fiber

ODF is mainly used for optical-fibers splicing, fixing, and connection. The connection modes
are given as following:

. Connection between optical cables and optical equipment:



31
ODF Product Profile
. Cross connection between optical cable and optical equipment
Direct connection between optical cables



32
ODF Product Profile
. Connection between optical cables through adapter
. Cross connection between optical cables



33
Contents
1. ODF optical-fiber Distribution Frame
Product Profile
2. Introduction to Huawei ODF Product
3. Surveys of Huawei ODF Product




34
Introduce to Huawei ODF Product
ODF Product
Wall mount
Frame Series
Cabinet Series
Management
Frame Series
Box
GPX147-B

GPX147-R
GPX147-C,PX147-CZ
GPX147-F
GPX147-OMF
GPX147-E



35
Contents
1. ODF (optical-fiber Distribution Frame)
Product Profile
2. Introduction to Huawei ODF Product
Particular Description refer to appendix
3. Surveys of Huawei ODF Product




36
Surveys of Huawei ODF Product
Engineering
survey


Net height of room &
height of
antistatic floor

Adapter
model
Capacity
expansion
project
Height of room & net height of room ;
height of raised floor;
length of grounding wire;
Dimension of frame/cabinet (main height)
Cable outlet mode ( upper outlet or lower outlet) ;
Adapter model;
Model of tail fiber, such as :single tail fiber
(main), bundle tail fiber, Ribbon tail fiber
Needed information , such as manufacture ,model
and specifications of existing ODF;
Ensure the equipment compatible and in
accordance with the existing ones ;
ISSUE

Training About MDF Survey
1.0

Auxiliary equipment Product Line
JUNE, 2005
Wen Hua Shu



38
Contents
1. MDF (Main Distribution Frame)
Product Profile

2. Introduction to Huawei MDF
Products (Particular Description refer to
Appendix)

3. MDF Survey




39
1. MDF products in traditional communication network
MDF Product Profile

IP
HONET
Trunk cable
Optical-
fiber
D
W
D
M
D
W
D
M
Optical
transmissi-
on network
ODF
ODF
DWDM
ODF
ODF
ATM875
Optix W32
C&C08
ODF
DDF
EAST8000
DDF
ODF
DDF
ODF
DDF
DDF
DDF
ODF ODF
C&C08
Optix 155/622/2500/10G
Optix W32
Optix
METRO
DDF
DDF
Copper
cable
C&C08
C&C08
HONET
HONET
Optix 155/622/2500/10G
Optix 155/622/2500/10G
Optix 155/622/2500/10G
Optix 155/622/2500/10G
MDF
METRO
MDF
MDF
MDF
MDF
ODF CATV SDH
SDH SDH
SDH
SDH
SDH
SDH
SDH
SDH
JPX202
JPX202
JPX202
JPX202
JPX256
MDF
JPX256



40
MDF Product Profile
2.MDF product in local connection
Main functions of MDF: connection, testing, protection, give alarm;

MDF is a connection and protection device in the local communication lines. One end
of MDF is connected with cables of local communication lines, another end is connected
to the subscribers lines of exchange . MDF have functions, such as connection with
internal and external lines cables, providing protection to lines, giving alarm and testing
lines.
Cross-
connection
Cabinet
Cable Dis-
tribution
Box
Intra-office cable
Intra-office
Outside office
Main cables
MDF
Switch/
Exchange
Distribution cables
Subscriber
Termination
Equiptment
Internal cables External cables



41
FRAME
Cable side
terminal block
Alarm system
Exchange
side
terminal
block
MDF Product Profile
FRAME/CABINET
Cable side Terminal
block
Exchange side
terminal block
Protective unit
Alarm system
Accessories
3. Structure of MDF



42
MDF Product Profile
Exchange side terminal block Cable side terminal block



43
4. Correlative Definition for MDF
Main Distribution Frame (MDF)is a device for connection and protection in the local
communication lines, the external lines of MDF connect the copper-core twisted pair local
call cables and the internal lines connect the subscriber lines of telecom exchange or
access equipment .
Double-side jumper MDF: is composed of back-to-back horizontal and vertical rows, in
which the horizontal rows are used to install exchange side terminal blocks, and the
vertical rows are used to install cable side terminal blocks.
Single-side jumper MDF: has both the jumper terminals of external and internal lines set
on the same side. A single-side jumper MDF is constructed by terminal frames and
corresponding horizontal and vertical wiring troughs, and can be lined in multiple columns.
The cable side terminal blocks and exchange side terminal blocks can be either
separately installed on different terminal frames or mixed installed on the same terminal
frames.
Cable side terminal block: is used for terminating external cables and connecting
jumpers, and also can be equipped with a protective unit (generally known as vertical
terminal block, protective-testing connecting block, protective connecting block, external
cable terminal block , and so on ).
Exchange side terminal block: is used for terminating intra-office cables and connecting
jumpers, and is able to implement test (generally known as horizontal terminal block,
testing connecting block, internal cable terminal connecting block , and so on ) .
Protective unit: is used to prevent injury on the operator and damage on equipment
caused by over-voltage and over-current, also known as protector.
MDF Product Profile



44
5.Composing of MDF
MDF Product Profile
Frame: can be sorted as double-sided frame, single-sided frame, and wall-
mounted frame according to cabling mode or installation mode.
Cabinet :can be sorted as double-sided cabinet, single-sided cabinet, and wall-
mounted cabinet according to cabling mode or installation mode.
Cable side terminal block: can be sorted as 10/20 pair terminal strip, 100/200
pair terminal block according to distribution capacity;
Can be sorted as welding connection type, wrapping connecting type, half IDC and
half wrapping connection type and IDC connection type according to connection
mode;
Can be sorted as stationary type, revolving type according to structure;
Exchange side terminal block: can be sorted as 8/16 pair terminal strip, 128/256
pair terminal block according to distribution capacity;
Can be sorted as welding connection type, wrapping connecting type, half IDC and
half wrapping connection type and IDC connection type according to connection
mode;
Can be sorted as stationary type, revolving type according to structure;
Protective unit: can be sorted as gas discharge tube type and semiconductor
arrester type according to the type of discharge tube;
Can be sorted as non-self-recovery type and self-recovery type according to the
characteristic of over-current device.




45
MDF Product Profile
6.Alarm system and Accessories
A
c
c
e
s
s
o
r
i
e
s


IDC tool
Testing plug
Open-circuit plug
Ladder
Alarm system



46
MDF Product Profile



47
MDF Product Profile



48
7. Alarm system and Accessories of MDF
MDF Product Profile
Alarm system: when protective unit is plugged in the cable side terminal block
properly, it connects with grounding terminal and alarm signal terminal; connect
every single-column alarm in series by using the wires in the back of MDF and
then connect to the general alarm, thus a completed alarm system is formed.

IDC (Insulation Displacement Connection) tool: the special tool used to
terminate the cables to corresponding terminals, which can be sorted as wrapping
connection gun and IDC tool;

Testing plug: is the plug-in unit used to testing internal and external lines;

Open-circuit plug: is the plastic insulating unit used to disconnect the connection
of internal and external lines;
Ladder: is used for maintenance, which can be sorted as movable ladder, slide
ladder and high stool according to structure.



49
Contents
1. MDF (Main Distribution Frame)
Product Profile

2. Introduction to Huawei MDF
Products (Particular Description
refer to Appendix)

3. MDF Surveys





50
Introduction to Huawei MDF Products
1.JPX202 MDF series product



Double-sided
frame F
Single-sided
frame SF
Wall-mounted
frame GQ
Cabinet B
Cabinet C
Frame/
cabinet

Cable side
terminal block
FA8-72
Exchange side
terminal block
STO-83A


STO-83B
Protective
unit
FA9-81B
FA9-83
Alarm
IDC tool
Testing plug
CSS
Open-circuit
plug KLS
Ladder

J
P
X

2
0
2


M
D
F




51
Introduction to Huawei MDF Products
2.Application of JPX202 MDF



Double-sided frame F: applicable to large office or equipment room
with sufficient space;

Wall-mounted frame GQ: applicable to enterprise or the office where
MDF need to be installed on walls;

Cabinet B/C: applicable to small capacity office or equipment where
there are distribution frames and other cabinet-type devices.
J
P
X
2
0
2

M
D
F

Single-sided frame SF: applicable to small office or equipment room
with limited space , where MDF need to be installed against walls ;



52
3.JPX256 MDF (mainly applicable to access network ONU built-in type):
Introduction to Huawei MDF Products




Double-sided
frame F
Single-sided
frame SF
Wall-mounted
frame GQ
Cabinet A
Frame/cabinet

Cable side
terminal block
FA8-123
Exchange side
terminal block
STO-128


Protective
unit
FA9-172 FA9-173
Alarm IDC tool
Testing plug
CSS
Open-circuit
plug KLS
Ladder
J
P
X
2
5
6


M
D
F

Using parts of JPX202 MDF
Proprietary parts of JPX256 MDF



53
4.Cable side terminal block FA8-123 and exchange side terminal block STO-128
FA8-123 is a 10-pair cable side terminal block ;
The protective unit is unplugged from the front of
terminal block, and the visual alarm is display in front of
the terminal block too, which is convenient for
troubleshooting;
introduce cables from the back of the terminal block,
connect jumpers on both side , insert or remove wires
with IDC tool in front the terminal blocks.

STO-128 is a 8-pair exchange side terminal block ;
introduce cables from the back of the terminal block,
connect jumpers on both side , insert or remove wires
with IDC tool in front the terminal blocks.
Introduction to Huawei MDF Products

FA8-123
STO-128



54
5.Protective unit FA9-173 and FA9-172
FA9-173 gas discharge tube protective unit:
is the plug-in unit with over-current and
over-voltage protection functions and FS
alarm function , it can be used in FA8-123
cable side terminal block.




FA9-172 semiconductor arrester
protective unit: is the plug-in unit with over-
current and over-voltage protection
functions and alarm function , it can be
used in FA8-123 cable side terminal block.
Introduction to Huawei MDF Products

FA9-173
FA9-172



55
6.Testing cord and open-circuit plug
Testing cord: is the plug-in unit used to
test the internal and external lines. A pair
of clips are connected to the external
lines tester, the other pair of clips are
connected to internal lines tester or
telephone set.




Open-circuit plug: is a plastic insulating
unit used to disconnect the connection of
the internal or external lines on MDF. It
can be used in STO128 exchange side
terminal blocks.
Introduction to Huawei MDF Products
JPX256-CSS
JPX256-KLS



56
Contents

1. MDF (Main Distribution
Frame) Product Profile

2. Introduction to Huawei MDF
Products (Particular Description
refer to Appendix)

3. MDF Survey




57
Huawei MDF Product Surveys
1: JPX202 MDF Engineering surveys



Four major
points for
confirmation


Height of raised floor (mm)

Length of power cable for alarm
device(m)
Net height of Room/Shelter (mm)
Length of grounding cable (m)



58
2: Net Height of Room and Frame/Cabinet Size



HD W n1
double-sided MDF
30001250 250n F1
26001250 250n F2
22001000 250n F3
18001000 250n
Configure
according to
size

HD W
single-sided MDF
3000600 500n SF1
2600600 500n SF2
2200600 500n SF3
1800600 500n

HWD
wall-mounted MDF
530250210 GQ100
560500210 GQ200
970500210
HWD
Cabinet
2200660600 B1
800660220 A3
Height
Room
Depth
Width
Net height of room (mm): the vertical
distance from the lower surface of roof board
to the upper surface of the floor board (or
the ground level if there is no floor board) ;
Cabling method: the cable entry of external
line and internal line is from the upper or
lower side of the frame (cabinet); for upper
cable entry, the height of cabling trough
should be considered.

Huawei MDF Product Surveys



59
Huawei MDF Product Surveys


Height of Steel Base
250
280
300
330
350
380

Steel Base

Room/Shelter
Height
Floor board
Ground
Net height of Room/shelter floor (mm):
vertical distance from the ground surface
to the upper surface of the floor board
3: Net Height of Room/Shelter Floor
Configure
according to
height



60

Huawei MDF Product Survey
4: Length of Power Wire for Alarm device

MDF
Shelter
power supply of -48V
wire
Length of power wire for alarm
device(m): length of power wire from
MDF to power supply of -48V



61
Huawei MDF Product Survey
5: Length of Grounding Cable

MDF
General
grounding bus
of room/shelter
50mm~2 yellow-green round fireproof cable is adopted in frame
25mm~2 yellow-green round fireproof cable is adopted in cabinet
Length of grounding
cable (m): length of
grounding cable from
protection grounding bus
of room/shelter to MDF
grounding bar
Specification of grounding cable:



62