ERRATA

ACI 350.3-06
Seismic Design of Liquid-Containing Concrete Structures
and Commentary (ACI 350.3-06)
Reported by ACI Committee 350
3
rd
and 4
th
printings



Table 4.1.1(b), page 20, last footnote revised as:
Unanchored, uncontained tanks shall not be built in locations where S
DS
S
S

0.75.

Section R5.3.1, page 24, last paragraph revised as:
and the dynamic force on the trailing half of the tank will reduce the effects of the
hydrodynamic hydrostatic force on the wall.

Section R9.2.4, page 36, SI equation for k revised as:

[k =
| |
|

\ .
3
6
4 10
c w
E t
h

| |
|

\ .
3
3
4 10
c w
E t
h
in the SI system]

Section 9.4.1, page 39, revised as:

C
i
shall be determined as follows:

For T
I
T
i
T
S


Section 9.5, page 40, 2
nd
paragraph, revised as:

For periods less than or equal to..spectra at a period of 2 0.2 seconds









Copyright American Concrete Institute
Provided by IHS under license with ACI Licensee=Bechtel Corp Loc 1-19/9999056100
Not for Resale, 05/08/2013 14:43:59 MDT No reproduction or networking permitted without license from IHS
--`,`,`,,``,,``,`,,,,,,,,```-`-`,,`,,`,`,,`---


Section B.3, page 59, Eq. (B-7) and (B-8) revised as:

= c
i
r r
i
C I
P W
R
=
i
r r
i
C I
P W
R
(B-7)

= c
i
i i
i
C I
P W
R
=
i
i i
i
C I
P W
R
(B-8)




Updated 11-10-08, 9:53 a.m.