You are on page 1of 5

2013 Kaelus. All Rights Reserved.

www.kaelus.com
TBC0019F1V1 Issue h.doc


|1|





| SAME BAND COMBINER, UMTS2100, PASSIVE, THREE-WAY










PRODUCT FEATURES

- Allows three UMTS2100 base stations to
share feeders, TMAs and antennas
- RoHS compliant
- Twin 19in rack mounted unit



TECHNICAL SPECIFICATIONS |


| B-1 TX/RX PORT (MAIN AND DIV) DOWNLINK (TX) PATH

Passband 2130-2150MHz
Insertion loss 0.4dB typ, 0.7dB max at band edge
Return loss 18dB min
EVM across 4MHz channel 7% max, 1% typ

| B-1 TX/RX PORT (MAIN AND DIV) UPLINK (RX) PATH

Passband 1940-1960MHz
Insertion loss 1.0dB typ, 1.5dB max
Return loss 18dB min
EVM across 4MHz channel 7% max, 1% typ

| B-2 TX/RX PORT (MAIN AND DIV) DOWNLINK (RX) PATH

Passband 2110-2120MHz
Insertion loss 0.4dB typ, 0.7dB max at band edge
Return loss 18dB min
EVM across 4MHz channel 7% max, 1% typ
TBC0019F1V1

The Kaelus TBC0019 provides a cost effective way
of combining three 2100MHz node-Bs into a single
feeder system thereby minimizing insertion losses,
capital expenditure and operational costs.


2013 Kaelus. All Rights Reserved.
www.kaelus.com
TBC0019F1V1 Issue h.doc


|2|




TECHNICAL SPECIFICATIONS CONTINUED |



| B-2 TX/RX PORT (MAIN AND DIV) UPLINK (RX) PATH

Passband 1920-1930MHz
Insertion loss 1.0dB typ, 1.5dB max
Return loss 18dB min
EVM across 4MHz channel 7% max, 1% typ

| B-3 TX/RX PORT (MAIN AND DIV) DOWNLINK (RX) PATH

Passband 2160-2170MHz
Insertion loss 0.4dB typ, 0.7dB max at band edge
Return loss 18dB min
EVM across 4MHz channel 7% max, 1% typ

| B-3 TX/RX PORT (MAIN AND DIV) UPLINK (RX) Path

Passband 1970-1980MHz
Insertion loss 1.0dB typ, 1.5dB max
Return loss 18dB min
EVM across 4MHz channel 7% max, 1% typ

| B-1 TX/RX MAIN TO B-2 TX/RX MAIN PORT AND B-2 TX/RX DIV TO B-1 TX/RX

Isolation In B1 TX frequency range 25dB min
Isolation In B2 TX frequency range 25dB min
Isolation In B3 TX frequency range 25dB min
Isolation In B1 RX frequency range 20dB min
Isolation In B2 RX frequency range 20dB min
Isolation In B3 RX frequency range 20dB min
Isolation In B3 RX frequency range 20dB min

| ELECTRICAL GENERAL

Impedance 50ohms
Intermodulation 160dBc with 2 x 43dBm TX carriers (7th order)
RF power handling B1 160W average / 1000W PIP
RF power handling B2, B3 100W average / 1000W PIP


2013 Kaelus. All Rights Reserved.
www.kaelus.com
TBC0019F1V1 Issue h.doc


|3|



TECHNICAL SPECIFICATIONS CONTINUED |



| ENVIRONMENTAL

For details regarding environmental compliance, please contact Kaelus.
Operating temperature range 20 to 45C | 68 to 113F
Environmental sealing Indoor unit
Operating altitude 2,000m | 6,561ft max
Relative humidity
095% without condensation (0.06 liter max of water per liter of
dry air)

| MECHANICAL

Dimensions, 19in rack mounted
2U height
450 x 245 x 89mm | 17.71 x 9.64 x 3.50in
Weight 11.0kg | 24.3lbs
Connectors DIN 7-16 (F) long shank x 6
Mounting 19in rack



ORDERING INFORMATION |


Kaelus Part Number Kaelus Description
TBC0019F1V1 No DC/AISG paths fitted
TBC0019FxVyy Various DC/AISG pass options available

x = Denotes frequency tuning.
yy = Denotes DC/AISG options available on request


2013 Kaelus. All Rights Reserved.
www.kaelus.com
TBC0019F1V1 Issue h.doc


|4|
TX1:
2130-2150
RX1:
1940-1960
TX2:
2110-2120
RX2:
1920-1930
TX3:
2160-2170
RX3:
1970-1980
TX1:
2130-2150
RX1:
1940-1960
TX2:
2110-2120
RX2:
1920-1930
TX3:
2160-2170
RX3:
1970-1980
NODE B-1
MAIN
NODE B-2
MAIN
NODE B-3
MAIN
NODE B-1
DIV
NODE B-2
DIV
NODE B-3
DIV



ELECTRICAL BLOCK DIAGRAM |

























2013 Kaelus. All Rights Reserved.
www.kaelus.com
TBC0019F1V1 Issue h.doc


|5|



MECHANICAL BLOCK DIAGRAM |




DIN 7/16(F) x 8 M6 EARTH STUD
THIRD ANGLE
PROJECTION
444.0
415.0
2
4
5
.
0
2
7
0
.
7
2
9
.
5
5
8
.
5
6
8
.
0
7
.
0
10.0
2
1
.
8
6
6
.
2
8
8
.
0
0
.
0
8
.
8
5
8
.
8
1
0
2
.
8
1
4
6
.
7
2
0
6
.
3
2
1
1
.
5
2
7
6
.
3
3
3
5
.
9
3
7
9
.
8
4
2
3
.
8
4
7
3
.
8
4
8
2
.
6







Information contained within this datasheet is valid at the time of release and may be reviewed by Kaelus at any time.