Water is filled into the sump tank of the Hydraulic Bench until approximately 80% full.
2.
The outlet flow control valve is fully opened at the apparatus and the water flow is
4.
The flow control valve for inlet flow is gradually opened and the piping is allowed to fill
with water until all air has been expelled from the system.
5. The pump is switched on
2.
3.
Procedures
1.
2. The appropriate valves are opened and closed to obtain flow of water through the
required test pipe.
3. Flow rates are measured using the volumetric tank in conjunction with flow control
valve.
4.
For small flow rates, the measuring cylinder is used to in conjunction with flow control.
5.
Head loss between the tapping is measured using the pressurized water measurement.
6.
The testing with different flowrate is repeated and reading on test section is obtained.
7.
A 90 bend
2.
A 90 elbow
3.
A 45 elbow
4.
A 45 Y
5.
A 90 T
6.
A sudden enlargement
7.
A sudden contraction
Procedures
1.
2.
The appropriate valves are opened and closed to obtain flow of water through the
Flow rates are measured using the volumetric tank in conjunction with flow control
valve.
4.
Differential head between tapping on each fitting is measured with pressurized water
manometer.
5.
Differential head between tapping on test valves is measured using pressurized water
manometer.
6.
The testing with different flow rate is repeated and the readings on test section is
obtained.
7.
2.
3.
Then, the inlet water supply valve on hydraulics bench is fully closed.
4.
5.
The water in sump tank is retained for the next study session.