DERIVATION FOR UNIT

DERIVATION FOR UNIT WEIGHT OF


REINFORCEMENT BAR (D X D/162)
We know the formula D2/162 which is being used
for calculate unit weight of reinforcement per
meter.

Weight of bar per meter = Area of steel bar X Density of


steel x Length of bar

[http://4.bp.blogspot.com/xBUTUrK8fUM/UFRRGNdIDTI/AAAAAAAAADg/nObGeMrZn2c/s1600/Reinforc
ement-Steel-Bar.jpg]

= (3.14 x D2 /4) x 7850 kg/m3 x 1000 mm


= (3.14 x D2 /4) x 1000 x 7850 / (1000 x 1000 x 1000)
= D2 X 785.714285714286 x 0.00000785
= D2 X 0.006162
= D2 X 1/(0.006162)
= (D2 /162.28)
The actual value is D2 /162.28