You are on page 1of 19

OMNIS_CPFL - Controller Tag Listing

OMNIS_CPFL (Controller)

Name
ALARME_IND_SUPER
INDICAO SUPERVISORIO
External Access:
ALARME_IND_SUPER1
INDICAO SUPERVISORIO2
External Access:
AUTOMATICO_FLARE
External Access:
AUX_PART_FLARE
External Access:
AUX_TRAFO
External Access:
AUX_XVFLARE
External Access:
B0
External Access:
B0[0]
B0[1]
B0[2]
B0[3]
B0[4]
B0[8]
B1
External Access:
B1[0]
B1[1]
B1[2]
B1[3]
B1[4]
B1[8]
B2
External Access:
B2[0]
B2[1]
B2[2]
B2[3]
B2[4]
B2[8]
BLOQ_HOR1
External Access:
BLOQ_HOR2
External Access:
BLOQ_HOR3
External Access:
BLOQ_HOR4
External Access:
BLOQ_HOR5
External Access:
BLOQ_HOR6
External Access:
BLOQ_HOR7
External Access:
BLOQ_HOR8
External Access:
BLOQUEIO1
External Access:
BLOQUEIO1.DN
BLOQUEIO2
External Access:
BLOQUEIO2.DN
BLOQUEIO3
External Access:
BLOQUEIO3.DN
BLOQUEIO4
External Access:
BLOQUEIO4.DN
BLOQUEIO5

Page 1
05/09/2014 18:56:28
E:\Omnis_biogas\OMNIS_CPFL.ACD

Value
0

Data Type
BOOL

Scope
OMNIS_CPFL

Read/Write
0

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL[32]

OMNIS_CPFL

BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL[32]

OMNIS_CPFL

BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL[32]

OMNIS_CPFL

BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

Read/Write
1
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
Read/Write
0
0
0
0
0
0
Read/Write
0
0
0
0
0
0
Read/Write
0
0
0
0
0
0
1
Read/Write
1
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
Read/Write
1
Read/Write
1
Read/Write
0
Read/Write
0

Logix Designer

OMNIS_CPFL - Controller Tag Listing


OMNIS_CPFL (Controller)

BLOQUEIO5 (Continued)
External Access:
Read/Write
1
BLOQUEIO5.DN
BLOQUEIO6
External Access:
Read/Write
0
BLOQUEIO6.DN
BLOQUEIO7
External Access:
Read/Write
0
BLOQUEIO7.DN
BLOQUEIO8
External Access:
Read/Write
1
BLOQUEIO8.DN
BLOQUEIO9
External Access:
Read/Write
0
BLOQUEIO9.DN
BLOQUEIO10
External Access:
Read/Write
1
BLOQUEIO10.DN
1
BOT_VALV_AUTO
Constant
No
External Access:
Read/Write
COMPR_GERADOR
External Access:
Read/Write
descarte_1
External Access:
Read/Write
1
descarte_1.EnableIn
Enable Input - System Defined Parameter
1
descarte_1.EnableOut
Enable Output - System Defined Parameter
descarte_2
External Access:
Read/Write
1
descarte_2.EnableIn
Enable Input - System Defined Parameter
1
descarte_2.EnableOut
Enable Output - System Defined Parameter
DESL
External Access:
Read/Write
0
DESL.DN
0
DESLIGA_P155
Constant
No
External Access:
Read/Write
0
DESLIGA_P156
Constant
No
External Access:
Read/Write
0
DESLIGA_P158
Constant
No
External Access:
Read/Write
0
DESLIGA_P159
Constant
No
External Access:
Read/Write
0
DESLIGA_P191
Constant
No
External Access:
Read/Write
0
DESLIGA_P3001A
Constant
No
External Access:
Read/Write
0
DESLIGA_P3001B
Constant
No
External Access:
Read/Write
100.0
ENT_VALOR_VV1
Constant
No
External Access:
Read/Write
38
FIT20002
External Access:
Read/Write
60
FT_30253
External Access:
Read/Write
horas1
External Access:
Read/Write

Page 2
05/09/2014 18:56:30
E:\Omnis_biogas\OMNIS_CPFL.ACD

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
BOOL

OMNIS_CPFL

PID

OMNIS_CPFL

horimetro

OMNIS_CPFL

BOOL
BOOL
horimetro

OMNIS_CPFL

BOOL
BOOL
TIMER

OMNIS_CPFL

BOOL
BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

REAL

OMNIS_CPFL

DINT

OMNIS_CPFL

DINT

OMNIS_CPFL

COUNTER

OMNIS_CPFL

Logix Designer

OMNIS_CPFL - Controller Tag Listing


OMNIS_CPFL (Controller)

horas1 (Continued)
horas1.PRE
horas1.DN
horas2
External Access:
horas2.PRE
horas2.DN
horas3
External Access:
horas3.PRE
horas3.DN
horas4
External Access:
horas4.PRE
horas4.DN
horas5
External Access:
horas5.PRE
horas5.DN
horas6
External Access:
horas6.PRE
horas6.DN
horas7
External Access:
horas7.PRE
horas7.DN
horas8
External Access:
horas8.PRE
horas8.DN
inverter155
External Access:
inverter156
External Access:
inverter158
External Access:
inverter159
External Access:
inverter190
External Access:
inverter191
External Access:
inverter30001A
External Access:
inverter30001B
External Access:
LIGA_P155
Constant
External Access:
LIGA_P156
Constant
External Access:
LIGA_P158
Constant
External Access:
LIGA_P159
Constant
External Access:
LIGA_P191
Constant
External Access:
LIGA_P3001A
Constant
External Access:
LIGA_P3001B
Constant
External Access:

0
1
Read/Write
0
1
Read/Write
24
0
Read/Write
24
0
Read/Write
12
0
Read/Write
12
0
Read/Write
24
0
Read/Write
24
0
0
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
0
No
Read/Write
0
No
Read/Write
0
No
Read/Write
0
No
Read/Write
0
No
Read/Write
0
No
Read/Write
0
No
Read/Write

Page 3
05/09/2014 18:56:31
E:\Omnis_biogas\OMNIS_CPFL.ACD
DINT
BOOL
COUNTER

OMNIS_CPFL

DINT
BOOL
COUNTER

OMNIS_CPFL

DINT
BOOL
COUNTER

OMNIS_CPFL

DINT
BOOL
COUNTER

OMNIS_CPFL

DINT
BOOL
COUNTER

OMNIS_CPFL

DINT
BOOL
COUNTER

OMNIS_CPFL

DINT
BOOL
COUNTER

OMNIS_CPFL

DINT
BOOL
BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

BOOL

OMNIS_CPFL

Logix Designer

OMNIS_CPFL - Controller Tag Listing


OMNIS_CPFL (Controller)

Local:1:I
External Access:
Local:2:I
External Access:
Local:3:O
External Access:
Local:4:I
External Access:
Local:5:I
External Access:
Local:6:O
External Access:
minutos1
External Access:
minutos1.DN
minutos2
External Access:
minutos2.DN
minutos3
External Access:
minutos3.DN
minutos4
External Access:
minutos4.DN
minutos5
External Access:
minutos5.DN
minutos6
External Access:
minutos6.DN
minutos7
External Access:
minutos7.DN
minutos8
External Access:
minutos8.DN
ONS
External Access:
ONS[22]
ONS[30]
ONS[31]
ONS_FLARE1
External Access:
P_155:I
External Access:
P_155:I.Active
P_155:I.Faulted
P_155:I.OutputFreq
P_155:I.OutputCurrent
P_155:O

Page 4
05/09/2014 18:56:32
E:\Omnis_biogas\OMNIS_CPFL.ACD
AB:1769_DI32:I:0

OMNIS_CPFL

AB:1769_DI32:I:0

OMNIS_CPFL

AB:1769_DO32:O:0

OMNIS_CPFL

AB:1769_IF16:I:0

OMNIS_CPFL

AB:1769_IF16:I:0

OMNIS_CPFL

AB:1769_OF4:O:0

OMNIS_CPFL

COUNTER

OMNIS_CPFL

BOOL
COUNTER

OMNIS_CPFL

BOOL
COUNTER

OMNIS_CPFL

BOOL
COUNTER

OMNIS_CPFL

BOOL
COUNTER

OMNIS_CPFL

BOOL
COUNTER

OMNIS_CPFL

BOOL
COUNTER

OMNIS_CPFL

BOOL
COUNTER

OMNIS_CPFL

BOOL
BOOL[32]

OMNIS_CPFL

BOOL
BOOL
BOOL
BOOL

OMNIS_CPFL

Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
0
Read/Write
1
0
0
1
Read/Write

AB:PowerFlex525V_E_1EC61CCC:I:0
OMNIS_CPFL
Read/Write
0
0
0
0

BOMBA DE CIRCULAAO PRIMRIA 1


External Access:
Read/Write
2#0000_0000_0000_1001
P_155:O.LogicCommand
BOMBA DE CIRCULAAO PRIMRIA 1
0
P_155:O.LogicCommand.1
BOMBA DE CIRCULAAO PRIMRIA 1
1
P_155:O.Stop
BOMBA DE CIRCULAAO PRIMRIA 1
0
P_155:O.Start
BOMBA DE CIRCULAAO PRIMRIA 1
0
P_155:O.Jog
BOMBA DE CIRCULAAO PRIMRIA 1
1
P_155:O.ClearFaults
BOMBA DE CIRCULAAO PRIMRIA 1
0
P_155:O.Forward
BOMBA DE CIRCULAAO PRIMRIA 1

BOOL
BOOL
INT
INT
AB:PowerFlex525V_EENET_Drive:O:0
OMNIS_CPFL
INT
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL

Logix Designer

OMNIS_CPFL - Controller Tag Listing


OMNIS_CPFL (Controller)

P_155:O (Continued)
0
P_155:O.Reverse
BOMBA DE CIRCULAAO PRIMRIA 1
0
P_155:O.ForceKeypadCtrl
BOMBA DE CIRCULAAO PRIMRIA 1
0
P_155:O.MOPIncrement
BOMBA DE CIRCULAAO PRIMRIA 1
0
P_155:O.AccelRate1
BOMBA DE CIRCULAAO PRIMRIA 1
0
P_155:O.AccelRate2
BOMBA DE CIRCULAAO PRIMRIA 1
0
P_155:O.DecelRate1
BOMBA DE CIRCULAAO PRIMRIA 1
0
P_155:O.DecelRate2
BOMBA DE CIRCULAAO PRIMRIA 1
0
P_155:O.FreqSel01
BOMBA DE CIRCULAAO PRIMRIA 1
0
P_155:O.FreqSel02
BOMBA DE CIRCULAAO PRIMRIA 1
0
P_155:O.FreqSel03
BOMBA DE CIRCULAAO PRIMRIA 1
0
P_155:O.MOPDecrement
BOMBA DE CIRCULAAO PRIMRIA 1
3900
P_155:O.FreqCommand
BOMBA DE CIRCULAAO PRIMRIA 1
P_156:I
External Access:
P_156:I.Active
P_156:I.Faulted
P_156:I.OutputFreq
P_156:I.OutputCurrent
P_156:O

Read/Write
1
0
3900
1284

BOMBA DE CIRCULAO PRIMARIA 2


External Access:
Read/Write
2#0000_0000_0001_0010
P_156:O.LogicCommand
BOMBA DE CIRCULAO PRIMARIA 2
1
P_156:O.LogicCommand.1
BOMBA DE CIRCULAO PRIMARIA 2
0
P_156:O.Stop
BOMBA DE CIRCULAO PRIMARIA 2
1
P_156:O.Start
BOMBA DE CIRCULAO PRIMARIA 2
0
P_156:O.Jog
BOMBA DE CIRCULAO PRIMARIA 2
0
P_156:O.ClearFaults
BOMBA DE CIRCULAO PRIMARIA 2
1
P_156:O.Forward
BOMBA DE CIRCULAO PRIMARIA 2
0
P_156:O.Reverse
BOMBA DE CIRCULAO PRIMARIA 2
0
P_156:O.ForceKeypadCtrl
BOMBA DE CIRCULAO PRIMARIA 2
0
P_156:O.MOPIncrement
BOMBA DE CIRCULAO PRIMARIA 2
0
P_156:O.AccelRate1
BOMBA DE CIRCULAO PRIMARIA 2
0
P_156:O.AccelRate2
BOMBA DE CIRCULAO PRIMARIA 2
0
P_156:O.DecelRate1
BOMBA DE CIRCULAO PRIMARIA 2
0
P_156:O.DecelRate2
BOMBA DE CIRCULAO PRIMARIA 2
0
P_156:O.FreqSel01
BOMBA DE CIRCULAO PRIMARIA 2
0
P_156:O.FreqSel02
BOMBA DE CIRCULAO PRIMARIA 2

Page 5
05/09/2014 18:56:35
E:\Omnis_biogas\OMNIS_CPFL.ACD
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
INT
AB:PowerFlex525V_E_1EC61CCC:I:0
OMNIS_CPFL
BOOL
BOOL
INT
INT
AB:PowerFlex525V_EENET_Drive:O:0
OMNIS_CPFL
INT
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL

Logix Designer

OMNIS_CPFL - Controller Tag Listing


OMNIS_CPFL (Controller)

P_156:O (Continued)
0
P_156:O.FreqSel03
BOMBA DE CIRCULAO PRIMARIA 2
0
P_156:O.MOPDecrement
BOMBA DE CIRCULAO PRIMARIA 2
3800
P_156:O.FreqCommand
BOMBA DE CIRCULAO PRIMARIA 2
P_158:I
External Access:
P_158:I.Active
P_158:I.Faulted
P_158:I.OutputFreq
P_158:I.OutputCurrent
P_158:O

Read/Write
0
0
0
0

BOMBA DE CIRCULAO SECUNDRIA 1


External Access:
Read/Write
2#0000_0000_0000_0001
P_158:O.LogicCommand
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.LogicCommand.1
BOMBA DE CIRCULAO SECUNDRIA 1
1
P_158:O.Stop
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.Start
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.Jog
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.ClearFaults
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.Forward
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.Reverse
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.ForceKeypadCtrl
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.MOPIncrement
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.AccelRate1
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.AccelRate2
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.DecelRate1
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.DecelRate2
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.FreqSel01
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.FreqSel02
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.FreqSel03
BOMBA DE CIRCULAO SECUNDRIA 1
0
P_158:O.MOPDecrement
BOMBA DE CIRCULAO SECUNDRIA 1
2000
P_158:O.FreqCommand
BOMBA DE CIRCULAO SECUNDRIA 1
P_159:I
External Access:
P_159:I.Active
P_159:I.Faulted
P_159:I.OutputFreq
P_159:I.OutputCurrent
P_159:O

Read/Write
1
0
2060
439

BOMBA DE CIRCULAO SECUNDRIA 2


External Access:
Read/Write
2#0000_0000_0000_0010
P_159:O.LogicCommand

Page 6
05/09/2014 18:56:35
E:\Omnis_biogas\OMNIS_CPFL.ACD
BOOL
BOOL
INT
AB:PowerFlex525V_E_1EC61CCC:I:0
OMNIS_CPFL
BOOL
BOOL
INT
INT
AB:PowerFlex525V_EENET_Drive:O:0
OMNIS_CPFL
INT
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
INT
AB:PowerFlex525V_E_1EC61CCC:I:0
OMNIS_CPFL
BOOL
BOOL
INT
INT
AB:PowerFlex525V_EENET_Drive:O:0
OMNIS_CPFL
INT
Logix Designer

OMNIS_CPFL - Controller Tag Listing


OMNIS_CPFL (Controller)

P_159:O (Continued)
BOMBA DE CIRCULAO SECUNDRIA 2
1
P_159:O.LogicCommand.1
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.Stop
BOMBA DE CIRCULAO SECUNDRIA 2
1
P_159:O.Start
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.Jog
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.ClearFaults
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.Forward
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.Reverse
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.ForceKeypadCtrl
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.MOPIncrement
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.AccelRate1
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.AccelRate2
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.DecelRate1
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.DecelRate2
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.FreqSel01
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.FreqSel02
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.FreqSel03
BOMBA DE CIRCULAO SECUNDRIA 2
0
P_159:O.MOPDecrement
BOMBA DE CIRCULAO SECUNDRIA 2
2060
P_159:O.FreqCommand
BOMBA DE CIRCULAO SECUNDRIA 2
P_190:I
External Access:
P_190:I.Active
P_190:I.Faulted
P_190:I.OutputFreq
P_190:I.OutputCurrent
P_190:O
BOMBA DE VINHAA 1
External Access:
P_190:O.LogicCommand
BOMBA DE VINHAA 1
P_190:O.LogicCommand.1
BOMBA DE VINHAA 1
P_190:O.Stop
BOMBA DE VINHAA 1
P_190:O.Start
BOMBA DE VINHAA 1
P_190:O.Jog
BOMBA DE VINHAA 1
P_190:O.ClearFaults
BOMBA DE VINHAA 1
P_190:O.Forward
BOMBA DE VINHAA 1
P_190:O.Reverse
BOMBA DE VINHAA 1
P_190:O.ForceKeypadCtrl
BOMBA DE VINHAA 1
P_190:O.MOPIncrement

Read/Write
1
0
5200
693

Page 7
05/09/2014 18:56:36
E:\Omnis_biogas\OMNIS_CPFL.ACD

BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
INT
AB:PowerFlex525V_E_1EC61CCC:I:0
OMNIS_CPFL
BOOL
BOOL
INT
INT
AB:PowerFlex525V_EENET_Drive:O:0
OMNIS_CPFL

Read/Write
2#0000_0000_0000_0010

INT

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL
Logix Designer

OMNIS_CPFL - Controller Tag Listing


OMNIS_CPFL (Controller)

P_190:O (Continued)
BOMBA DE VINHAA 1
P_190:O.AccelRate1
BOMBA DE VINHAA 1
P_190:O.AccelRate2
BOMBA DE VINHAA 1
P_190:O.DecelRate1
BOMBA DE VINHAA 1
P_190:O.DecelRate2
BOMBA DE VINHAA 1
P_190:O.FreqSel01
BOMBA DE VINHAA 1
P_190:O.FreqSel02
BOMBA DE VINHAA 1
P_190:O.FreqSel03
BOMBA DE VINHAA 1
P_190:O.MOPDecrement
BOMBA DE VINHAA 1
P_190:O.FreqCommand
BOMBA DE VINHAA 1
P_191:I
External Access:
P_191:I.Active
P_191:I.Faulted
P_191:I.OutputFreq
P_191:I.OutputCurrent
P_191:O
BOMBA DE VINHAA 1
External Access:
P_191:O.LogicCommand
BOMBA DE VINHAA 1
P_191:O.LogicCommand.1
BOMBA DE VINHAA 1
P_191:O.Stop
BOMBA DE VINHAA 1
P_191:O.Start
BOMBA DE VINHAA 1
P_191:O.Jog
BOMBA DE VINHAA 1
P_191:O.ClearFaults
BOMBA DE VINHAA 1
P_191:O.Forward
BOMBA DE VINHAA 1
P_191:O.Reverse
BOMBA DE VINHAA 1
P_191:O.ForceKeypadCtrl
BOMBA DE VINHAA 1
P_191:O.MOPIncrement
BOMBA DE VINHAA 1
P_191:O.AccelRate1
BOMBA DE VINHAA 1
P_191:O.AccelRate2
BOMBA DE VINHAA 1
P_191:O.DecelRate1
BOMBA DE VINHAA 1
P_191:O.DecelRate2
BOMBA DE VINHAA 1
P_191:O.FreqSel01
BOMBA DE VINHAA 1
P_191:O.FreqSel02
BOMBA DE VINHAA 1
P_191:O.FreqSel03
BOMBA DE VINHAA 1
P_191:O.MOPDecrement
BOMBA DE VINHAA 1
P_191:O.FreqCommand

Page 8
05/09/2014 18:56:37
E:\Omnis_biogas\OMNIS_CPFL.ACD

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

5200

INT
AB:PowerFlex525V_E_1EC61CCC:I:0
OMNIS_CPFL

Read/Write
0
0
0
0

BOOL
BOOL
INT
INT
AB:PowerFlex525V_EENET_Drive:O:0
OMNIS_CPFL

Read/Write
2#0000_0000_0000_0001

INT

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

5200

INT
Logix Designer

OMNIS_CPFL - Controller Tag Listing


OMNIS_CPFL (Controller)

P_191:O (Continued)
BOMBA DE VINHAA 1
P_319:I
External Access:
P_319:I.Active
P_319:I.Faulted
P_319:I.OutputFreq
P_319:I.OutputCurrent
P_319:O
SOPRADOR 1 PTU
External Access:
P_319:O.LogicCommand
SOPRADOR 1 PTU
P_319:O.LogicCommand.1
SOPRADOR 1 PTU
P_319:O.Stop
SOPRADOR 1 PTU
P_319:O.Start
SOPRADOR 1 PTU
P_319:O.Jog
SOPRADOR 1 PTU
P_319:O.ClearFaults
SOPRADOR 1 PTU
P_319:O.Forward
SOPRADOR 1 PTU
P_319:O.Reverse
SOPRADOR 1 PTU
P_319:O.ForceKeypadCtrl
SOPRADOR 1 PTU
P_319:O.MOPIncrement
SOPRADOR 1 PTU
P_319:O.AccelRate1
SOPRADOR 1 PTU
P_319:O.AccelRate2
SOPRADOR 1 PTU
P_319:O.DecelRate1
SOPRADOR 1 PTU
P_319:O.DecelRate2
SOPRADOR 1 PTU
P_319:O.FreqSel01
SOPRADOR 1 PTU
P_319:O.FreqSel02
SOPRADOR 1 PTU
P_319:O.FreqSel03
SOPRADOR 1 PTU
P_319:O.MOPDecrement
SOPRADOR 1 PTU
P_319:O.FreqCommand
SOPRADOR 1 PTU
P_322:I
External Access:
P_322:I.Active
P_322:I.Faulted
P_322:I.OutputFreq
P_322:I.OutputCurrent
P_322:O
SOPRADOR 2 PTU
External Access:
P_322:O.LogicCommand
SOPRADOR 2 PTU
P_322:O.LogicCommand.1
SOPRADOR 2 PTU
P_322:O.Stop
SOPRADOR 2 PTU

Page 9
05/09/2014 18:56:37
E:\Omnis_biogas\OMNIS_CPFL.ACD

AB:PowerFlex525V_E_1EC61CCC:I:0
OMNIS_CPFL
Read/Write
1
0
4800
1541

BOOL
BOOL
INT
INT
AB:PowerFlex525V_EENET_Drive:O:0
OMNIS_CPFL

Read/Write
2#0000_0000_0000_0010

INT

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

4800

INT
AB:PowerFlex525V_E_1EC61CCC:I:0
OMNIS_CPFL

Read/Write
1
0
4800
1500

BOOL
BOOL
INT
INT
AB:PowerFlex525V_EENET_Drive:O:0
OMNIS_CPFL

Read/Write
2#0000_0000_0001_1010

INT

BOOL

BOOL

Logix Designer

OMNIS_CPFL - Controller Tag Listing


OMNIS_CPFL (Controller)

P_322:O (Continued)
P_322:O.Start
SOPRADOR 2 PTU
P_322:O.Jog
SOPRADOR 2 PTU
P_322:O.ClearFaults
SOPRADOR 2 PTU
P_322:O.Forward
SOPRADOR 2 PTU
P_322:O.Reverse
SOPRADOR 2 PTU
P_322:O.ForceKeypadCtrl
SOPRADOR 2 PTU
P_322:O.MOPIncrement
SOPRADOR 2 PTU
P_322:O.AccelRate1
SOPRADOR 2 PTU
P_322:O.AccelRate2
SOPRADOR 2 PTU
P_322:O.DecelRate1
SOPRADOR 2 PTU
P_322:O.DecelRate2
SOPRADOR 2 PTU
P_322:O.FreqSel01
SOPRADOR 2 PTU
P_322:O.FreqSel02
SOPRADOR 2 PTU
P_322:O.FreqSel03
SOPRADOR 2 PTU
P_322:O.MOPDecrement
SOPRADOR 2 PTU
P_322:O.FreqCommand
SOPRADOR 2 PTU
P_3001A:I
External Access:
P_3001A:I.Active
P_3001A:I.Faulted
P_3001A:I.OutputFreq
P_3001A:I.OutputCurrent
P_3001A:O
COMPRESSOR FLARE A
External Access:
P_3001A:O.LogicCommand
COMPRESSOR FLARE A
P_3001A:O.LogicCommand.1
COMPRESSOR FLARE A
P_3001A:O.Stop
COMPRESSOR FLARE A
P_3001A:O.Start
COMPRESSOR FLARE A
P_3001A:O.Jog
COMPRESSOR FLARE A
P_3001A:O.ClearFaults
COMPRESSOR FLARE A
P_3001A:O.Forward
COMPRESSOR FLARE A
P_3001A:O.Reverse
COMPRESSOR FLARE A
P_3001A:O.ForceKeypadCtrl
COMPRESSOR FLARE A
P_3001A:O.MOPIncrement
COMPRESSOR FLARE A
P_3001A:O.AccelRate1
COMPRESSOR FLARE A
P_3001A:O.AccelRate2
COMPRESSOR FLARE A

Page 10
05/09/2014 18:56:38
E:\Omnis_biogas\OMNIS_CPFL.ACD

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

4800

INT
AB:PowerFlex525V_E_1EC61CCC:I:0
OMNIS_CPFL

Read/Write
0
0
0
0

BOOL
BOOL
INT
INT
AB:PowerFlex525V_EENET_Drive:O:0
OMNIS_CPFL

Read/Write
2#0000_0000_0000_0001

INT

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

Logix Designer

OMNIS_CPFL - Controller Tag Listing


OMNIS_CPFL (Controller)

P_3001A:O (Continued)
P_3001A:O.DecelRate1
COMPRESSOR FLARE A
P_3001A:O.DecelRate2
COMPRESSOR FLARE A
P_3001A:O.FreqSel01
COMPRESSOR FLARE A
P_3001A:O.FreqSel02
COMPRESSOR FLARE A
P_3001A:O.FreqSel03
COMPRESSOR FLARE A
P_3001A:O.MOPDecrement
COMPRESSOR FLARE A
P_3001A:O.FreqCommand
COMPRESSOR FLARE A
P_3001B:I
External Access:
P_3001B:I.Active
P_3001B:I.Faulted
P_3001B:I.OutputFreq
P_3001B:I.OutputCurrent
P_3001B:O
COMPRESSOR FLARE B
External Access:
P_3001B:O.LogicCommand
COMPRESSOR FLARE B
P_3001B:O.LogicCommand.1
COMPRESSOR FLARE B
P_3001B:O.Stop
COMPRESSOR FLARE B
P_3001B:O.Start
COMPRESSOR FLARE B
P_3001B:O.Jog
COMPRESSOR FLARE B
P_3001B:O.ClearFaults
COMPRESSOR FLARE B
P_3001B:O.Forward
COMPRESSOR FLARE B
P_3001B:O.Reverse
COMPRESSOR FLARE B
P_3001B:O.ForceKeypadCtrl
COMPRESSOR FLARE B
P_3001B:O.MOPIncrement
COMPRESSOR FLARE B
P_3001B:O.AccelRate1
COMPRESSOR FLARE B
P_3001B:O.AccelRate2
COMPRESSOR FLARE B
P_3001B:O.DecelRate1
COMPRESSOR FLARE B
P_3001B:O.DecelRate2
COMPRESSOR FLARE B
P_3001B:O.FreqSel01
COMPRESSOR FLARE B
P_3001B:O.FreqSel02
COMPRESSOR FLARE B
P_3001B:O.FreqSel03
COMPRESSOR FLARE B
P_3001B:O.MOPDecrement
COMPRESSOR FLARE B
P_3001B:O.FreqCommand
COMPRESSOR FLARE B
PARTIDA
External Access:
PARTIDA.DN
PCV_30105

Page 11
05/09/2014 18:56:38
E:\Omnis_biogas\OMNIS_CPFL.ACD

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

132

INT
AB:PowerFlex525V_E_1EC61CCC:I:0
OMNIS_CPFL

Read/Write
0
0
0
0

BOOL
BOOL
INT
INT
AB:PowerFlex525V_EENET_Drive:O:0
OMNIS_CPFL

Read/Write
2#0000_0000_0000_0001

INT

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

BOOL

100

INT

Read/Write
0
16383

TIMER

OMNIS_CPFL

BOOL
INT

OMNIS_CPFL
Logix Designer

OMNIS_CPFL - Controller Tag Listing


OMNIS_CPFL (Controller)

PCV_30105 (Continued)
VALVULA DE CONTROLE MOTORIZADA PCV30105
AliasFor:
Local:6:O.Ch2Data
Base Tag:
Local:6:O.Ch2Data
Constant
No
External Access:
Read/Write
1.5
PI_30203_PAL1
Constant
No
External Access:
Read/Write
0.18
PI_30203_PAL2
Constant
No
External Access:
Read/Write
PID_FIT20002
External Access:
Read/Write
PID_PCV30105
External Access:
Read/Write
1
PID_PCV30105.SWM
100.0
PID_PCV30105.SO
60
PIT30104
External Access:
Read/Write
60
PIT30106
External Access:
Read/Write
PLE20160
External Access:
Read/Write
0
PLE20160.EnableIn
Enable Input - System Defined Parameter
0
PLE20160.EnableOut
Enable Output - System Defined Parameter
primaria_1
External Access:
Read/Write
0
primaria_1.EnableIn
Enable Input - System Defined Parameter
0
primaria_1.EnableOut
Enable Output - System Defined Parameter
primaria_2
External Access:
Read/Write
1
primaria_2.EnableIn
Enable Input - System Defined Parameter
1
primaria_2.EnableOut
Enable Output - System Defined Parameter
PULSO_START_OFF
External Access:
Read/Write
0
PULSO_START_OFF.DN
PULSO_START_ON
External Access:
Read/Write
0
PULSO_START_ON.DN
reset_horimetro
Constant
No
External Access:
Read/Write
0
reset_horimetro[0]
0
reset_horimetro[1]
0
reset_horimetro[2]
0
reset_horimetro[3]
0
reset_horimetro[4]
0
reset_horimetro[5]
0
reset_horimetro[6]
0
reset_horimetro[7]
0
reset_horimetro[8]
0
reset_horimetro[9]
0
reset_horimetro[10]
0
reset_horimetro[11]
0
reset_horimetro[12]
16184
RETORNO_PCV30105
RETORNO DE ABERTURA DA PCV 30105
AliasFor:
Local:5:I.Ch14Data
Base Tag:
Local:5:I.Ch14Data
Constant
No
External Access:
Read/Write

Page 12
05/09/2014 18:56:39
E:\Omnis_biogas\OMNIS_CPFL.ACD

REAL

OMNIS_CPFL

REAL

OMNIS_CPFL

PID

OMNIS_CPFL

PID

OMNIS_CPFL

BOOL
REAL
DINT

OMNIS_CPFL

DINT

OMNIS_CPFL

horimetro

OMNIS_CPFL

BOOL
BOOL
horimetro

OMNIS_CPFL

BOOL
BOOL
horimetro

OMNIS_CPFL

BOOL
BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
BOOL[32]

OMNIS_CPFL

BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
INT

OMNIS_CPFL

Logix Designer

OMNIS_CPFL - Controller Tag Listing


OMNIS_CPFL (Controller)

secundaria_1
External Access:
Read/Write
0
secundaria_1.EnableIn
Enable Input - System Defined Parameter
0
secundaria_1.EnableOut
Enable Output - System Defined Parameter
secundaria_2
External Access:
Read/Write
1
secundaria_2.EnableIn
Enable Input - System Defined Parameter
1
secundaria_2.EnableOut
Enable Output - System Defined Parameter
segundos1
External Access:
Read/Write
0
segundos1.DN
segundos2
External Access:
Read/Write
0
segundos2.DN
segundos3
External Access:
Read/Write
0
segundos3.DN
segundos4
External Access:
Read/Write
0
segundos4.DN
segundos5
External Access:
Read/Write
0
segundos5.DN
segundos6
External Access:
Read/Write
0
segundos6.DN
segundos7
External Access:
Read/Write
0
segundos7.DN
segundos8
External Access:
Read/Write
0
segundos8.DN
soprador_1
External Access:
Read/Write
1
soprador_1.EnableIn
Enable Input - System Defined Parameter
1
soprador_1.EnableOut
Enable Output - System Defined Parameter
soprador_2
External Access:
Read/Write
1
soprador_2.EnableIn
Enable Input - System Defined Parameter
1
soprador_2.EnableOut
Enable Output - System Defined Parameter
TEMP_BIOGAS
External Access:
Read/Write
0
TEMP_BIOGAS.TT
1
TEMP_BIOGAS.DN
55
TEMP_MAX
Constant
No
External Access:
Read/Write
40
TEMP_MIN
Constant
No
External Access:
Read/Write
TEMPORIZADOR1
External Access:
Read/Write
0
TEMPORIZADOR1.DN
TEMPORIZADOR2
External Access:
Read/Write
0
TEMPORIZADOR2.DN
TEMPORIZADOR3
External Access:
Read/Write
0
TEMPORIZADOR3.DN
timer

Page 13
05/09/2014 18:56:40
E:\Omnis_biogas\OMNIS_CPFL.ACD
horimetro

OMNIS_CPFL

BOOL
BOOL
horimetro

OMNIS_CPFL

BOOL
BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
horimetro

OMNIS_CPFL

BOOL
BOOL
horimetro

OMNIS_CPFL

BOOL
BOOL
TIMER

OMNIS_CPFL

BOOL
BOOL
DINT

OMNIS_CPFL

DINT

OMNIS_CPFL

TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL
Logix Designer

OMNIS_CPFL - Controller Tag Listing


OMNIS_CPFL (Controller)

timer (Continued)
External Access:
Read/Write
0
timer.DN
timer1
External Access:
Read/Write
0
timer1.DN
timer2
External Access:
Read/Write
0
timer2.DN
timer3
External Access:
Read/Write
0
timer3.DN
timer4
External Access:
Read/Write
0
timer4.DN
timer5
External Access:
Read/Write
0
timer5.DN
timer6
External Access:
Read/Write
0
timer6.DN
timer7
External Access:
Read/Write
0
timer7.DN
12
valor_entrada_PLE20155
Constant
No
External Access:
Read/Write
12
valor_entrada_PLE20156
Constant
No
External Access:
Read/Write
24
valor_entrada_PLE20158
Constant
No
External Access:
Read/Write
24
valor_entrada_PLE20159
Constant
No
External Access:
Read/Write
24
valor_entrada_PLV10190
Constant
No
External Access:
Read/Write
24
valor_entrada_PLV10191
Constant
No
External Access:
Read/Write
0
valor_entrada_VE30001A
valor entrada horas troca
Constant
No
External Access:
Read/Write
0
valor_entrada_VE30001B
Constant
No
External Access:
Read/Write
1
VALV_AUTO
External Access:
Read/Write
VAZAO_BIODIGESTOR_EMER
External Access:
Read/Write
VAZAO_BIODIGESTOR_EMER.SP
232.0
ventilador_1
External Access:
Read/Write
0
ventilador_1.EnableIn
Enable Input - System Defined Parameter
0
ventilador_1.EnableOut
Enable Output - System Defined Parameter
ventilador_2
External Access:
Read/Write
0
ventilador_2.EnableIn
Enable Input - System Defined Parameter
0
ventilador_2.EnableOut
Enable Output - System Defined Parameter
vinhaca_2

Page 14
05/09/2014 18:56:41
E:\Omnis_biogas\OMNIS_CPFL.ACD

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
TIMER

OMNIS_CPFL

BOOL
DINT

OMNIS_CPFL

DINT

OMNIS_CPFL

DINT

OMNIS_CPFL

DINT

OMNIS_CPFL

DINT

OMNIS_CPFL

DINT

OMNIS_CPFL

DINT

OMNIS_CPFL

DINT

OMNIS_CPFL

BOOL

OMNIS_CPFL

PID

OMNIS_CPFL

REAL
horimetro

OMNIS_CPFL

BOOL
BOOL
horimetro

OMNIS_CPFL

BOOL
BOOL
horimetro

OMNIS_CPFL
Logix Designer

OMNIS_CPFL - Controller Tag Listing


OMNIS_CPFL (Controller)

vinhaca_2 (Continued)
External Access:
Read/Write
0
vinhaca_2.EnableIn
Enable Input - System Defined Parameter
0
vinhaca_2.EnableOut
Enable Output - System Defined Parameter
vinhaca1
External Access:
Read/Write
1
vinhaca1.EnableIn
Enable Input - System Defined Parameter
1
vinhaca1.EnableOut
Enable Output - System Defined Parameter

Page 15
05/09/2014 18:56:42
E:\Omnis_biogas\OMNIS_CPFL.ACD

BOOL
BOOL
horimetro

OMNIS_CPFL

BOOL
BOOL

Logix Designer

COMPR_GERADOR - Tag Properties


OMNIS_CPFL (Controller)
PID Properties Report

Page 16
05/09/2014 18:56:43
E:\Omnis_biogas\OMNIS_CPFL.ACD

Properties - PID tag: COMPR_GERADOR


Tuning
Setpoint (SP):
Set Output:
Output Bias:

10.0
100.0 %
0.0 %

MANUAL MODES
Manual:
Software Manual:

No
No

TUNING CONSTANTS
Proportional Gain (Kp):
Integral Gain (Ki):
Derivative Time (Kd):

1.5
0.01 1/s
0.0 s

Configuration
PID Equation:
Control Action:
Derivative Of:
Loop Update Time:
CV High Limit:
CV Low Limit:
Deadband Value:

Independent
SP - PV
PV
0.01 secs.
100.0 %
0.0 %
0.0

No Derivative Smoothing:
No Bias Calculation:
No Zero Crossing for Deadband:
PV Tracking:
Cascade Loop:
Cascade Type:

No
No
No
No
No
N/A

Alarms
Process Variable (PV) High:
Process Variable (PV) Low:
Process Variable (PV) Deadband:

0.0
0.0
0.0

Positive Deviation:
Negative Deviation:
Deviation Deadband:

0.0
0.0
0.0

Scaling
PROCESS VARIABLE (PV)
Unscaled Max.:
Unscaled Min.:

16383.0
0.0

Engineering Unit Max.:


Engineering Unit Min.:

200.0
0.0

CONTROL VARIABLE (CV)


Max. (at 100 %):
Min. (at 0 %):

60.0
0.0

TIEBACK
Max. (at 100 %):
Min. (at 0 %):

4095.0
0.0

PID Initialized:

Yes

Logix Designer

PID_FIT20002 - Tag Properties


OMNIS_CPFL (Controller)
PID Properties Report

Page 17
05/09/2014 18:56:44
E:\Omnis_biogas\OMNIS_CPFL.ACD

Properties - PID tag: PID_FIT20002


Tuning
Setpoint (SP):
Set Output:
Output Bias:

55.5
64.09825 %
0.0 %

MANUAL MODES
Manual:
Software Manual:

No
No

TUNING CONSTANTS
Proportional Gain (Kp):
Integral Gain (Ki):
Derivative Time (Kd):

1.2
0.02 1/s
0.0 s

Configuration
PID Equation:
Control Action:
Derivative Of:
Loop Update Time:
CV High Limit:
CV Low Limit:
Deadband Value:

Independent
SP - PV
PV
0.01 secs.
100.0 %
0.0 %
0.0

No Derivative Smoothing:
No Bias Calculation:
No Zero Crossing for Deadband:
PV Tracking:
Cascade Loop:
Cascade Type:

No
No
No
No
No
N/A

Alarms
Process Variable (PV) High:
Process Variable (PV) Low:
Process Variable (PV) Deadband:

0.0
0.0
0.0

Positive Deviation:
Negative Deviation:
Deviation Deadband:

0.0
0.0
0.0

Scaling
PROCESS VARIABLE (PV)
Unscaled Max.:
Unscaled Min.:

16383.0
0.0

Engineering Unit Max.:


Engineering Unit Min.:

600.0
0.0

CONTROL VARIABLE (CV)


Max. (at 100 %):
Min. (at 0 %):

60.0
0.0

TIEBACK
Max. (at 100 %):
Min. (at 0 %):

4095.0
0.0

PID Initialized:

Yes

Logix Designer

PID_PCV30105 - Tag Properties


OMNIS_CPFL (Controller)
PID Properties Report

Page 18
05/09/2014 18:56:45
E:\Omnis_biogas\OMNIS_CPFL.ACD

Properties - PID tag: PID_PCV30105


Tuning
Setpoint (SP):
Set Output:
Output Bias:

90.0
100.0 %
0.0 %

MANUAL MODES
Manual:
Software Manual:

No
Yes

TUNING CONSTANTS
Proportional Gain (Kp):
Integral Gain (Ki):
Derivative Time (Kd):

1.5
0.01 1/s
0.0 s

Configuration
PID Equation:
Control Action:
Derivative Of:
Loop Update Time:
CV High Limit:
CV Low Limit:
Deadband Value:

Independent
PV - SP
PV
0.01 secs.
100.0 %
0.0 %
0.0

No Derivative Smoothing:
No Bias Calculation:
No Zero Crossing for Deadband:
PV Tracking:
Cascade Loop:
Cascade Type:

No
No
No
No
No
N/A

Alarms
Process Variable (PV) High:
Process Variable (PV) Low:
Process Variable (PV) Deadband:

0.0
0.0
0.0

Positive Deviation:
Negative Deviation:
Deviation Deadband:

0.0
0.0
0.0

Scaling
PROCESS VARIABLE (PV)
Unscaled Max.:
Unscaled Min.:

16383.0
0.0

Engineering Unit Max.:


Engineering Unit Min.:

5000.0
0.0

CONTROL VARIABLE (CV)


Max. (at 100 %):
Min. (at 0 %):

16383.0
0.0

TIEBACK
Max. (at 100 %):
Min. (at 0 %):

4095.0
0.0

PID Initialized:

Yes

Logix Designer

VAZAO_BIODIGESTOR_EMER - Tag Properties


OMNIS_CPFL (Controller)
PID Properties Report

Page 19
05/09/2014 18:56:46
E:\Omnis_biogas\OMNIS_CPFL.ACD

Properties - PID tag: VAZAO_BIODIGESTOR_EMER


Tuning
Setpoint (SP):
Set Output:
Output Bias:

232.0
100.0 %
0.0 %

MANUAL MODES
Manual:
Software Manual:

No
No

TUNING CONSTANTS
Proportional Gain (Kp):
Integral Gain (Ki):
Derivative Time (Kd):

1.5
0.02 1/s
0.0 s

Configuration
PID Equation:
Control Action:
Derivative Of:
Loop Update Time:
CV High Limit:
CV Low Limit:
Deadband Value:

Independent
SP - PV
PV
0.01 secs.
100.0 %
0.0 %
0.0

No Derivative Smoothing:
No Bias Calculation:
No Zero Crossing for Deadband:
PV Tracking:
Cascade Loop:
Cascade Type:

No
No
No
No
No
N/A

Alarms
Process Variable (PV) High:
Process Variable (PV) Low:
Process Variable (PV) Deadband:

0.0
0.0
0.0

Positive Deviation:
Negative Deviation:
Deviation Deadband:

0.0
0.0
0.0

Scaling
PROCESS VARIABLE (PV)
Unscaled Max.:
Unscaled Min.:

16383.0
0.0

Engineering Unit Max.:


Engineering Unit Min.:

600.0
0.0

CONTROL VARIABLE (CV)


Max. (at 100 %):
Min. (at 0 %):

60.0
0.0

TIEBACK
Max. (at 100 %):
Min. (at 0 %):

4095.0
0.0

PID Initialized:

Yes

Logix Designer