BACK PROPPING ANALYSIS:

REF.

LOADINGS:

ASCE 37-02

CL =
DL =
FL =
INL =

3.60
8.75
16.00
0.80

kN/m
kN/m
kN/m
kN/m

Construction Live Load


Weight of Concrete at the pouring level
Formwork Load
Incidental Live Load

Table -2
Pre- Calculated
Pre- Calculated
Assumption

LOADING DISTRIBUTION PER STORY LEVEL:


B_L =

H=
CL =
DL =
FL =
TCL =
TNL =

3.00 unitless

3.50
3.60
8.75
16.00

Number of Back Propping Level required

AT Nth LEVEL
Clear height between slab-slab
m
Construction Live Load
kN/m
Weight of Concrete
kN/m
Formwork Load
kN/m

28.35 kN/m
28.35 kN/m

ACI 347-2R-05

See Outline Dwg.

Construction Live Load = 3.60 kN/m


Weight of Concrete = 8.75 kN/m
Nth LEVEL

Table -2
Pre- Calculated
Pre- Calculated

Total Construction Load (Unfactored)


Unfactored Net Load on lvl (N-1)

28.35kN/m
H=
INL =

AT (N-1) LEVEL
Clear height between slab-slab
3.50 m
Incidental Load
0.80 kN/m

See Outline Dwg.


(N-1) LEVEL

Assumption

5.00 kN/m
TCL =
DsL =
TNL =

H=
INL =
TCL =
DsL =
TNL =

H=
INL =

29.15 kN/m
5.00 kN/m
24.15 kN/m

Total Construction Load (Unfactored)


Total Design Load of the Slab lvl. (N-1)
Unfactored Net Load on lvl (N-2)

AT (N-2) LEVEL
Clear height between slab-slab
3.50 m
Incidental Load
0.80 kN/m
24.95 kN/m
5.00 kN/m
19.95 kN/m

Total Construction Load (Unfactored)


Total Design Load of the Slab lvl. (N-2)
Unfactored Net Load on lvl (N-3)

AT (N-3) LEVEL
Clear height between slab-slab
3.50 m
Incidental Load
0.80 kN/m

See Design Loads

24.15 kN/m

(N-2) LEVEL

See Outline Dwg.

5.00 kN/m

Assumption

19.95 kN/m

See Design Loads

(N-3) LEVEL

5.00 kN/m

See Outline Dwg.


Assumption

TCL =
DsL =
TNL =

20.75 kN/m
5.00 kN/m
15.75 kN/m

Total Construction Load (Unfactored)


Total Design Load of the Slab lvl. (N-3)
Unfactored Net Load on lvl (N-4)

15.75 kN/m

12.00 kN/m

TCL =
DsL =
TNL =

AT (N-4) LEVEL
Total Construction Load (Unfactored)
15.75 kN/m
Total Design Load of the Slab lvl. (N-4)
12.00 kN/m
Unfactored Net Load on lvl (N-5)
3.75 kN/m

See Design Loads


(N-4) LEVEL

See Design Loads

REMARKS:

PROVIDE MORE BACK PROPPING AT LEVEL BELOW (N-4)!


LEGENDS:
- FALSE WORK
- BACK PROPPING
- CURED CONCRETE SLAB
- SLAB TO BE CAST

J:\cris personal files\cris civil engineer\Cris Design Calculation template\Base Format\calculation (excel)\Latest\Back Propping Template