Part Name :
Part Number :
Line No. :
Forming Date :
Report Date :
Reason for Report:
Formability Status : Safe 30%
Part Name: Rear Door Inner Left Hand "A"Blank Part Number:
Die Number: NA
Date of Forming: NA
7288875
Observations
"A" blank portion of door inner is 30% safe strain state as evaluated using Circle Grid analysis
supported with ultrasonic thickness readings.,
Analyst was not present when Panel was gridded or formed.
No press settings or die recipe were recorded at time of forming.
Coil number was not available, analysis based on actual thickness measured on formed part
and minimum specified "N" value.
Binder surface show few wrinkles and only minor burnishing on the binder surface.
Recommendations
Second die redraws hinge area of panel deeper. A circle grid evaluation of that forming
operation should be conducted prior to chroming the draw die.
A review of press log for potential set-up changes on this die should be reviewed. If no
changes are documented, a current production draw panel should be obtained, with press and
die recipe recorded.
A thinning analysis and panel comparison should be conducted to verify that Circle Grid panel
matches current production conditions.
If thickness and quality checks confirm part duplication, press and die settings should be
established as production recipe.
7288875
80
70
Critical
% Major Strain
60
Marginal
50
40
Safe
30
20
3 1
5
2
10
0
-30
-20
-10
10
20
% Minor Strain
30
7288875
Final Thickness
Data Points
0.200
Critical Thickness
0.400
Marginal Thickness
0.600
Original Thickness
0.800
1.000
1.200
1.400
1.600
Safe
1.800
2.000
11 13 15 17
19 21 23
25 27 29
Measurement Point
Critical Thickness
Marginal Thickness
Original Thickness - Inches
Minimum n - VALUE
FLDo
FLD Marginal
1.198
1.286
1.745
0.200
45.7
35.7
31
7288875
7288875