You are on page 1of 12

Interconnecting Walkway #3 Design

Walkway Dead Weight

Point Load
Design weight, W
Angle of support,
h = L2/ tan b
L4 = L2 / sin b

=
=
=
=
=

928
9104
7500
16604
45
5000
7071

kg
N
N
N

mm
mm

( As per DEP 34.00.01.30-Gen )

(F2)
4151 N

(F1)
8302 N
X1= 2009

R2

(F3)
4151
X2=

983

A
L1 =

2992 mm

L2 =

5000 mm

R1

h=

5000

L3 =

5983 mm

P
b

L4 =

7071 mm

R3

Take Moment Balance at point A:


Summation MA = 0 :
F1 x L1 + F2 x L2 + F3 x L3 - R1 x L2 = 0
R1 =
14085 N
R2 = R3 = R1 tan b
=
14085 N
R1 / cos b
P =
=
19919 N
1 Check on bracing support size
Use member:
H-150 x 150 x 31.1 kg/m
Least Radius of Gyration, ry =
64 mm
2
Cross Sectional Area, A
=
3965 mm
Slenderness Ratio, l = 1.0 x L / ry =
110.49
Thus Allowable compressive stress, Fa =
11.54 ksi =
2
Compressive stress =
P/A=
5.02 N/mm
<

2
79.58 N/mm
Fa
*** Satisfactory !!!! ***

2 Check on support size


Used member:
Tensile stress:

Bending Stress:

C150 x 75 x 9t x 24 kg/m
2
A
=
3049 mm
St
=
R1 / A =
3
Z chosen =
141000 mm

2
4.6 N/mm

Bending Moment, BM = X2 x F3 + X1 x F1
=
20754600 Nmm
2
Sb
=
BM / Z =
147 N/mm

Yield Strength for struc.


A36
=
Allowable, Sy = 0.67 Yield =
Combined Stresses = St/Sy + Sb/Sy =

248 N/mm
2
166 N/mm
0.9
<
1.00
*** Satisfactory !!!! ***

Interconnecting Walkway #3 Design


Walkway Dead Weight

Point Load
Design weight, W
Angle of support,
h = L2/ tan b
L4 = L2 / sin b

=
=
=
=
=

500
4905
2000
6905
49
2941
4483

kg
N
N
N

mm
mm

( As per DEP 34.00.01.30-Gen )

(F2)
1726 N

(F1)
3453 N
X1= 3383

R2

(F3)
1726
X2=

-3383

A
L1 =

0 mm

L2 =

3383 mm

R1

h=

2941

L3 =

0 mm

P
b

L4 =

4483 mm

R3

Take Moment Balance at point A:


Summation MA = 0 :
F1 x L1 + F2 x L2 + F3 x L3 - R1 x L2 = 0
R1 =
1726 N
R2 = R3 = R1 tan b
=
R1 / cos b
P =
=

1986 N
2631 N

1 Check on bracing support size


Use member:
h 152x152
Least Radius of Gyration, ry =
Cross Sectional Area, A
=
Slenderness Ratio, l = 1.0 x L / ry =
Thus Allowable compressive stress, Fa =
Compressive stress =
P/A=

36.8 mm
2
2858 mm
121.81
11.94 ksi =
2
0.92 N/mm
<

2
82.34 N/mm
Fa
*** Satisfactory !!!! ***

2 Check on support size


Used member:
Tensile stress:

Bending Stress:

HE A 180 35.5 kg/m


2
A
=
4530 mm
St
=
R1 / A =
3
Z chosen =
294000 mm

2
0.4 N/mm

Bending Moment, BM = X2 x F3 + X1 x F1
=
5839904 Nmm
2
Sb
=
BM / Z =
20 N/mm

Yield Strength for struc.


A36
=
Allowable, Sy = 0.67 Yield =
Combined Stresses = St/Sy + Sb/Sy =

248 N/mm
2
166 N/mm
0.1
<
1.00
*** Satisfactory !!!! ***

Interconnecting Walkway #3 Design


Walkway Dead Weight

Point Load
Design weight, W
Angle of support,
h = L2/ tan b
L4 = L2 / sin b

=
=
=
=
=

2650
25997
2000
27997
54
3742
6366

kg
N
N
N

mm
mm

( As per DEP 34.00.01.30-Gen )

(F2)
6999 N

(F1)
13998 N
X1= 5150

R2

(F3)
6999
X2=

-5150

A
L1 =

0 mm

L2 =

5150 mm

R1

h=

3742

L3 =

0 mm

P
b

L4 =

6366 mm

R3

Take Moment Balance at point A:


Summation MA = 0 :
F1 x L1 + F2 x L2 + F3 x L3 - R1 x L2 = 0
R1 =
6999 N
R2 = R3 = R1 tan b
=
9633 N
R1 / cos b
P =
=
11908 N
1 Check on bracing support size
Use member:
H 203x203x9.27x6.6 30kg/M
Least Radius of Gyration, ry =
53.3 mm
2
Cross Sectional Area, A
=
5884 mm
Slenderness Ratio, l = 1.0 x L / ry =
119.43
Thus Allowable compressive stress, Fa =
10.28 ksi =
2
Compressive stress =
P/A=
2.02 N/mm
<

2
70.89 N/mm
Fa
*** Satisfactory !!!! ***

2 Check on support size


Used member:
Tensile stress:

Bending Stress:

HE A 180 35.5 kg/m


2
A
=
3787 mm
St
=
R1 / A =
3
Z chosen =
220000 mm

2
1.8 N/mm

Bending Moment, BM = X2 x F3 + X1 x F1
=
36045494 Nmm
2
Sb
=
BM / Z =
164 N/mm

Yield Strength for struc.


A36
=
Allowable, Sy = 0.67 Yield =
Combined Stresses = St/Sy + Sb/Sy =

248 N/mm
2
166 N/mm
1.0
<
1.00
*** Satisfactory !!!! ***

Interconnecting Walkway #3 Design


Walkway Dead Weight

Point Load
Design weight, W
Angle of support,
h = L2/ tan b
L4 = L2 / sin b

=
=
=
=
=

1000
9810
2000
11810
43
3628
4960

kg
N
N
N

mm
mm

( As per DEP 34.00.01.30-Gen )

(F2)
2953 N

(F1)
5905 N
X1= 3383

R2

(F3)
2953
X2=

-3383

A
L1 =

0 mm

L2 =

3383 mm

R1

h=

3628

L3 =

0 mm

P
b

L4 =

4960 mm

R3

Take Moment Balance at point A:


Summation MA = 0 :
F1 x L1 + F2 x L2 + F3 x L3 - R1 x L2 = 0
R1 =
2953 N
R2 = R3 = R1 tan b
=
R1 / cos b
P =
=

2753 N
4037 N

1 Check on bracing support size


Use member:
h 152x152
Least Radius of Gyration, ry =
Cross Sectional Area, A
=
Slenderness Ratio, l = 1.0 x L / ry =
Thus Allowable compressive stress, Fa =
Compressive stress =
P/A=

36.8 mm
2
2858 mm
134.79
11.94 ksi =
2
1.41 N/mm
<

2
82.34 N/mm
Fa
*** Satisfactory !!!! ***

2 Check on support size


Used member:
Tensile stress:

Bending Stress:

HE A 180 35.5 kg/m


2
A
=
4530 mm
St
=
R1 / A =
3
Z chosen =
294000 mm

2
0.7 N/mm

Bending Moment, BM = X2 x F3 + X1 x F1
=
9988308 Nmm
2
Sb
=
BM / Z =
34 N/mm

Yield Strength for struc.


A36
=
Allowable, Sy = 0.67 Yield =
Combined Stresses = St/Sy + Sb/Sy =

248 N/mm
2
166 N/mm
0.2
<
1.00
*** Satisfactory !!!! ***

Interconnecting Walkway #3 Design


Walkway Dead Weight

Point Load
Design weight, W
Angle of support,
h = L2/ tan b
L4 = L2 / sin b

=
=
=
=
=

1000
9810
2000
11810
48
2251
3364

kg
N
N
N

mm
mm

( As per DEP 34.00.01.30-Gen )

(F2)
2953 N

(F1)
5905 N
X1= 2500

R2

(F3)
2953
X2=

-2500

A
L1 =

0 mm

L2 =

2500 mm

R1

h=

2251

L3 =

0 mm

P
b

L4 =

3364 mm

R3

Take Moment Balance at point A:


Summation MA = 0 :
F1 x L1 + F2 x L2 + F3 x L3 - R1 x L2 = 0
R1 =
2953 N
R2 = R3 = R1 tan b
=
R1 / cos b
P =
=

3279 N
4412 N

1 Check on bracing support size


Use member:
h 152x152
Least Radius of Gyration, ry =
Cross Sectional Area, A
=
Slenderness Ratio, l = 1.0 x L / ry =
Thus Allowable compressive stress, Fa =
Compressive stress =
P/A=

36.8 mm
2
2858 mm
91.42
11.94 ksi =
2
1.54 N/mm
<

2
82.34 N/mm
Fa
*** Satisfactory !!!! ***

2 Check on support size


Used member:
Tensile stress:

Bending Stress:

HE A 180 35.5 kg/m


2
A
=
4530 mm
St
=
R1 / A =
3
Z chosen =
294000 mm

2
0.7 N/mm

Bending Moment, BM = X2 x F3 + X1 x F1
=
7381250 Nmm
2
Sb
=
BM / Z =
25 N/mm

Yield Strength for struc.


A36
=
Allowable, Sy = 0.67 Yield =
Combined Stresses = St/Sy + Sb/Sy =

248 N/mm
2
166 N/mm
0.2
<
1.00
*** Satisfactory !!!! ***

Weight Summary Of Platform


PLATFORM-1
Length
125.79 m
0 m

HE A180
IPE 180
Grating
Handrail
Toe Plate
Total load

kg
kg
kg
kg
kg
kg
2

22.391 m
2
1.961 kN/m
2
2 kN/m
2
3.961 kN/m
88.69075 kN
6 nos
14.78179 kN
1507.423 kg
H 152x152
3.81 cm
2
37.87 cm
2
39.80521 kg/cm

Area of platform
Dead Load
Live Load
Total Load
No. of col. Support
Load/Column

4465.545
0
1120
225
50
5860.545

Area x unit weight

Type of Column
Least Radius of Gyration
Sectional Area
Compressive Stress
Slenderness Ratio
Length of column

kl/r
718

71.8 cm
18.84514

Compressive stress for the


Slenderness Ratio

PLATFORM-2
HE A180
IPE 180
Grating
Handrail
Toe Plate

20 m
0 m

710
0
612
170
40
1532

Total load

Area of platform
Dead Load
Live Load
Total Load
No. of col. Support
Load/Column

Area x unit weight

Type of Column
Least Radius of Gyration
Sectional Area
Compressive Stress
Slenderness Ratio
Length of column

kg
kg
kg
kg
kg
kg

12.24 m
2
1.961 kN/m
2
2 kN/m
2
3.961 kN/m
48.48264 kN
5 nos
9.696528 kN
988.8362 kg
H 152x152
3.81 cm
2
3787 cm
2
0.261113 kg/cm
kl/r

852

85.2 cm
22.3622

PLATFORM-3
Length
HE A180
IPE 180
Grating
Handrail
Toe Plate

45 m
0 m

Total load

kg
kg
kg
kg
kg
kg
2

33 m
2
1.961 kN/m
2
2 kN/m
2
3.961 kN/m
130.713 kN
6 nos
21.7855 kN
2221.65 kg
H 152x152
3.81 cm
2
3787 cm
2
0.586652 kg/cm

Area of platform
Dead Load
Live Load
Total Load
No. of col. Support
Load/Column

1597.5
0
1640
250
50
3537.50

Area x unit weight

Type of Column
Radius of Gyration
Sectional Area
Compressive Stress
Slenderness Ratio
Length of column

kl/r
570

57 cm
14.96063

PLATFORM-4
HE A180
IPE 180
Grating
Handrail
Toe Plate

16.5 m
10.56 m

Total load

Area x unit weight

Type of Column
Radius of Gyration
Sectional Area
Compressive Stress
Slenderness Ratio
Length of column

kg
kg
kg
kg
kg
kg

17 m
2
1.961 kN/m
2
2 kN/m
2
3.961 kN/m
67.337 kN
4 nos
16.83425 kN
1716.73 kg
H 152x152
3.81 cm
2
3787 cm
2
0.453322 kg/cm

Area of platform
Dead Load
Live Load
Total Load
No. of col. Support
Load/Column

585.75
198.528
850
200
50
1884.278

kl/r
150

15 cm
3.937008

Weight Summary Of Platform


PLATFORM-1

HE A180
IPE 180
Grating
Handrail
Toe Plate

22.29
0

kg
kg
kg
kg
kg
kg
2

Area of platform
Dead Load
Live Load
Total Load
No. of col. Support
Load/Column
Type of Column
Least Radius of Gyration
Sectional Area
Compressive Stress
Slenderness Ratio
Length of column

791.295
0
1928
350
50
3119.295

600

HE A180
IPE 180
Grating
Handrail
Toe Plate

38.55 m
2
1.961 kN/m
2
2 kN/m
2
3.961 kN/m
152.6966 kN
5 nos
30.53931 kN
3114.349 kg
H 152x152
3.81 cm
2
3787 cm
2
82.2379 kg/cm

Area of platform
Dead Load
Live Load

kl/r

Slenderness Ratio
Length of column

60 cm
157.4803

Total Load
No. of col. Support
Load/Column
Type of Column
Radius of Gyration
Sectional Area
Compressive Stress

PLATFORM-2

PLATFORM-3

166
0

Area of platform
Dead Load

No. of col. Support


Load/Column
Type of Column
Radius of Gyration
Sectional Area
Compressive Stress
Slenderness Ratio
Length of column

5893
0
6250
1000
100
13243

kg
kg
kg
kg
kg
kg
2

HE A180
IPE 180
Grating
Handrail
Toe Plate

125 m
2
1.961 kN/m
2
2 kN/m
2
3.961 kN/m
495.125 kN
12 nos
41.26042 kN
4207.67 kg
H 152x152
3.81 cm
2
3787 cm
2
111.1083 kg/cm

Area of platform
Dead Load
Live Load

kl/r

Slenderness Ratio
Length of column

600 cm
1574.803

Total Load
No. of col. Support
Load/Column
Type of Column
Radius of Gyration
Sectional Area
Compressive Stress

23
0

816.5
0
800
300
50
1966.5
16
1.961
2
3.961
63.376
5
12.6752
1292.596
H 152x152
3.81
3787
34.13246
kl/r
600
1574.803

kg
kg
kg
kg
kg
kg
m2
kN/m2
kN/m2
2
kN/m
kN
nos
kN
kg
H 152x152
cm
cm2
kg/cm2

cm

You might also like