You are on page 1of 1

Length of Pile in Metres

Diameter of Pile in Millimetres(D)


l/D ratio
Cr (Reduction Coefficient Due to Length)
Area of Concrete in Sq. Millimetre (Ac)
Persentage of Steel Provided
Area of Steel in Sq. MilliMetre (Asc)
Diameter of Longitudinal bars in Millimetre
Number of bars Required
Number of bars Provided
Area of Steel Provided in Sq. MilliMetre (Ascpro)
Area of Concrete Provided in Sq. Millimetre (Acpro)
Percentage of Steel Provided (of the Gross Area)
Clear Cover in Millimetre
Spacing of Longitudinal Reinforcement
Horizontal Spacing Check
Load Capacity of Pile in kN

10.00 m
450.00 mm
22.22
0.75
2
158326.65 mm
0.0040 %
2
635.85 mm
12 mm
6 Nos
6 Nos
2
678.24 mm
158284.26
0.43
50
168
OK

mm2
%
mm
mm

571.50 kN

Lateral Reinforcement near Head of Pile


Required Steel per mm Length (0.6% of Gross Volume)
Tie
Length of Tie in Millimetre
Tie Area
Volume of each tie
Pitch
Max pitch

2
953.78 mm
8 mm
1073.88 mm
2
50.24 mm
3
53951.73 mm
60 mm
60 mm

Lateral Reinforcement near End of Pile


Required Steel per mm Length (0.6% of Gross Volume)
Tie
Length of Tie in Millimetre
Tie Area
Volume of each tie
Pitch
Max pitch

2
953.78 mm
8 mm
1073.88 mm
2
50.24 mm
3
47917.66 mm
50 mm
50 mm

Lateral Reinforcement near Body of Pile


Required Steel per mm Length (0.2% of Gross Volume)
Tie
Length of Tie in Millimetre
Tie Area
Volume of each tie
Pitch
Max pitch

2
317.93 mm
8 mm
1073.88 mm
2
50.24 mm
3
53951.73 mm
170 mm
150 mm