The Next Generation of


Air Conditioning Systems
Global Cooling Air Conditioning UK Ltd.

Please call now for more information


Tel: 01200 428888 - Fax: 01200 444252

http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/vrv-air-conditioning/
TT a b l e o f
C O N T E N T S
INTRODUCTION
Who is Daikin? p 4
The history of VRV systems p 6

W H AT I S ? p 8

THE INTELLIGENT AIR CONDITIONING SYSTEM p 10

P R O D U C T E X P L A N AT I O N p 12
Possible indoor units using R-410A p 14
Possible outdoor units using R-410A p 15
Main Features p 16
A Creating maximum comfort p 16
B Energy efficient solution p 18
C High reliability p 21
D Eco friendly p 23
E Easy and flexible design p 24
F Simple and rapid installation p 27

PRODUCT FEATURES OUTDOOR UNITS USING R-410A p 32


Survey outdoor units p 33
technology p 34
cooling only p 37
heat pump p 38
heat recovery p 40
NEW technology p 42
NEW heat pump / heat recovery p 43
Accessories p 44

P R O D U C T F E AT U R E S I N D O O R U N I T S U S I N G R - 4 1 0 A p 46
Survey indoor units p 47
FXZQ 4-way blow ceiling mounted cassette
(600mm x 600mm) p 48
FXFQ 4-way blow ceiling mounted cassette p 50
FXCQ 2-way blow ceiling mounted cassette p 52
FXKQ ceiling mounted corner cassette p 54
FXDQ concealed ceiling unit (small) p 56
FXDQ-N slim concealed ceiling unit p 58
FXSQ concealed ceiling unit p 60
FXMQ concealed ceiling unit (large) p 62
FXAQ wall mounted unit p 64
FXUQ 4-way blow ceiling suspended unit p 66
FXHQ ceiling suspended unit p 68
FXLQ floor standing unit p 70
FXNQ concealed floor standing unit p 70

P R O D U C T F E AT U R E S C O N T R O L S Y S T E M S p 72
Survey control systems p 73
Individual control systems p 74
Centralised control systems p 76
NEW p 77
NEW p 78
p 80
p 81

Accessories p 82
page
3
I
Introduction
Who is Daikin ?
Daikin has more than 70 years experience in manufacturing
advanced, high quality equipment air conditioning for
residential, commercial and industrial applications.

The Japanese mother company Daikin Industries Ltd. is


actively engaged in research into a wide spectrum of science
and disciplines, from mechanics and electronics to chemicals
and fluorocarbons.

Since its formation in 1972, Daikin Europe has evolved from


a component assembly plant into the most advanced air
conditioning manufacturing complex in Europe. All European
standards regarding production, health and safety are met
in full.

• The environment

Daikin’s unique position as a manufacturer of both fluoro


carbon refrigerants and air conditioning and refrigeration
equipment has not surprisingly led to its close involvement
in environmental issues.

Once ozone depletion in the stratosphere became


attributable to chloro fluoro carbon refrigerant chemicals
(CFCs), Daikin took the decision to cease both their
production and that of the products that use them. At the
same time, Daikin joined leading world manufacturers in
the research into safe and environmentally friendly
alternatives. The Environment Protection Agency of the
U.S.A afforded recognition of these efforts in June 2002
by presenting Daikin with its prestigious trophy for
the protection of the environment.

Daikin intends to become a leader in the provision of


environmentally friendly products. This challenge demands
the eco-design and development of a comprehensive
product range and an energy management system that
addresses energy conservation, reduction in waste and the
control of hazardous substances etc.

page
4
• ISO14001

ISO14001 assures an effective environmental management


system in order to help protect human health and the
environment from the potential impact of our activities,
products and services and to assist in maintaining and
improving the quality of the environment.
The European affiliate companies have plans to achieve
ISO 14001 by the year 2005, thereby contributing to Daikin’s
target of global status as a leading environment conscious
company. Economic benefits will surely follow the efforts
and investments needed to be a sustainable and socially
responsible enterprise.

• ISO9001

Daikin Europe N.V. is approved by LRQA for its Quality


Management System in accordance with the ISO9001
standard. ISO9001 pertains to quality assurance regarding
design, development, manufacturing as well as to services
related to the product.

• CE

Daikin units comply with the European regulations that


guarantee the safety of the product.

• Distribution network

Daikin maintains close contact with its markets through a


highly professional network of local distributors. Perceived
as an extension of the company’s “quality chain”, all
distributors are carefully trained in order to maintain high
quality sales, installation and after sales service to their
customers.

• Quality

The application of advanced technologies, combined with


careful selection of bought in components and extensive in
house testing and field trial procedures ensures unrivalled
product quality.

• Training

The Daikin training centre in Ostend is unique and the most


advanced of its kind in Europe. Both hands on and theoretical
instruction are provided into all aspects of the company’s air
conditioning equipment and systems and specially conceived
courses are available to suit distributors and their approved
dealers from all over Europe.

page
5
T
The History
of Systems
• 1987
The original VRV air conditioning system developed by
Daikin in 1982 is introduced into Europe in Standard
format. The system is able to supply conditioned air from up
to 4 indoor units connected to a single outdoor unit.

• 1990
The end of the year sees the launch of the new
Inverter system with the facility to operate up to 8 indoor
units from a single outdoor unit. Inverter capacity control
greatly increases system flexibility and efficiency.

• 1991
A further step forward is taken in 1991 with the intro-
duction of the Heat Recovery system, offering
simultaneous cooling and heating from different indoor
units on the same refrigeration circuit.

• 1992
Continuous improvements to energy efficiency and system
flexibility lead to the development of the advanced
in which fresh air supply (HRV) and computerised
management (DACMS) are integrated with the VRV.

• 1994
Consistent high quality and efficiency lead to the wide-
spread acceptance of the VRV concept and Daikin becomes
the first Japanese air conditioning manufacturer to be
awarded the ISO9001 certification.
But the search for improved flexibility and energy efficiency
does not stop there. Unrivalled field experience and close
regard for market requirements enables Daikin to apply yet
another quantum leap to VRV technology - the
Inverter-H series, operating up to 16 indoor units from just
1 outdoor unit !

• 1998
In anticipation of phase out dates for all CFC based
equipment, Daikin Europe steps up the production of VRV
air conditioning units using ozone friendly refrigerant.

Daikin Europe celebrates its 25th anniversary with the award


of an ISO14001 environmental certificate and the
introduction of Inverter K series with R-407C, in
cooling only or heat pump format. As many as 16 indoor
units can be connected to 1 single outdoor unit.

page
6
• 1999
The series using R-22 has been designed around
leading edge technologies to accommodate high capacity
air conditioning networks of up to 30 indoor units from a
single refrigerant circuit.

Another step forward has been taken with the launch of the
heat recovery series using R-407C and connecting up
to 16 indoor units to 1 single outdoor unit.

• 2000
Because of the growing needs of large-capacity systems
Daikin Europe introduces the series using ozone
friendly refrigerant, in heat pump format. Up to 32 indoor
units can be connected to a single refrigerant circuit.

• 2001
The latest addition to the VRV Plus series is the
heat recovery series using R-407C. Up to 32 indoor units can
be connected to a single refrigerant circuit.

• 2002
Daikin launches the new series – an environmental
friendly, energy saving series with high COP levels and
flexible design characteristics.

• 2003
Daikin Europe has achieved a quantum leap forward in
commercial air conditioning technology by the introduction
of its , the world’s first R-410A operated variable
refrigerant flow system. Available in cooling only, heat
pump and heat recovery versions, the new system, which
represents a considerable advance over earlier VRV systems,
demonstrates Daikin’s innovative application of new
technology and the latest HFC refrigerants to its VRV
product programmes. No less than 40 indoor units in heat
recovery as well as heat pump format can be connected to
a single refrigerant circuit.

• 2004
The introduction of the series extends VRV
operating scope into the light commercial sectors.
Available in 4, 5 and 6HP capacities, the system is designed
for installation in up to 9 rooms.

• 2005
Daikin has extended the operational scope of its acclaimed
VRVII inverter driven dx air conditioning system, with a new
water-cooled version, VRV-WII. Available in 10, 20 and 30HP
models, the system operates on R-410A refrigerant and is
available in both heat pump and heat recovery versions.

page
7
W
W h a t i s
?
In recent years, design styles for intelligent buildings such as
hotels, banks and offices etc. have increasingly featured large
areas of glazing with attendant high solar heat gains that
can only be dissipated by means of air conditioning.
Not surprisingly therefore, air conditioning has grown
in importance and is now widely accepted as an integral
component of most modern architectural concepts.

The increasing use of electronic office equipment raises


thermal loadings still further to a point whereby, even in
winter, internal temperatures can reach uncomfortable levels.
The demand for cooling or heating can also vary considerably
through-out the day depending on the number and
occupation of personnel on the premises. But end users have
come to expect far more than just cooling and heating from
their air conditioning.

The ideal modern system must AIR CONDITIONING


be energy efficient, easy to
install, flexible, reliable and
user friendly. Fresh air must be
supplied without increasing
energy consumption and the
role of central management
facilities should also be DAIKIN
NETWORK SOLUTION
considered in this respect for
medium to large sized
buildings. The Daikin Hi-VRV VENTILATION CONTROL AND
system meets all these MANAGEMENT
demands.

The innovative Hi-VRV selection programme, Daikin’s flag


ship software package, enables you to exploit the system’s
possibilities to the max and guarantees the end user a perfect
service.
From now on you can fully plan your Daikin air-conditioning
project on a step-by-step basis without difficulty.

page
9
TThe Intelligent
Air Conditioning System

Heat
Reclaim
Ventilation

heat and humidity are


exchanged between supply
and exhaust air, which
• brings outdoor air close to
indoor air conditions
• recovers energy loss
• realises considerable
reduction of air conditioning
capacity

page
10
Variable Refrigerant Volume

• available in cooling only, heat pump and heat recovery


formats.
• a rapid response system in which up to 40 indoor units can
operate on the same refrigerant circuit.
• an inverter driven compressor enables the output of
the outdoor unit to be modulated in accordance with
the cooling/heating demand of the zone which it controls.

DAIKIN
NETWORK SOLUTION

NEW
The ideal solution for control and management of
up to 2,000 indoor units.

Allows detailed and easy monitoring and operation of


VRV systems (maximum 2x64 control groups).

The ideal solution for control and management of


maximum 1,024 VRV indoor units.

LONWORKS® networks compatible gateway.

Integrated control system connecting VRV system with


BMS system.

page
11
P
P r o d u c t
E X P L A N A T I O N
INVERTER COOLING ONLY

• For cooling operation from one system


• Up to 16 indoor units can be operated from a single outdoor unit
without the need for an additional adapter PCB.
• The line-up of 5, 8, 10hp models is ideally suited to applications in
smaller facilities and minor expansions and upgrades.

/ INVERTER HEAT PUMP

• For either cooling or heating operation from one system


• Up to 40 indoor units can be operated from a VRVII single outdoor
unit (32 indoor units for VRV-WII) without the need for an additional
adapter PCB.
• An extensive capacity range starting at 5hp, then from 8hp to 48hp
in 2hp increments, for VRVII (10hp, 20hp & 30hp for VRV-WII),
meets all customer requirements concerning small to large buildings,
whether new or existing

/ HEAT RECOVERY

• For simultaneous cooling and heating operation from one system


• Up to 40 indoor units can be operated from a single outdoor unit
in VRVII heat recovery format. Maximum 32 indoor units for VRV-WII.
• Extensive capacity range from 8hp to 48hp in 2hp increments for
VRVII, (10hp, 20hp & 30hp for VRV-WII) meets all customer
requirements concerning small to large buildings, whether new or
existing.
• Heat recovery is achieved by diverting exhaust heat from indoor units
in cooling mode to areas requiring heating.
• The BS unit switches the system between cooling and heating modes.

page
13
P
Possible Indoor Units
Using R-410A
Type

4-way blow ceiling mounted


cassette (600mm x 600mm)
20 25 32 40 50 63 71 80 100 125 200 250

✘ ✘✘✘✘
FXZQ
4-way blow ceiling
mounted cassette ✘ ✘ ✘ ✘ ✘ ✘✘ ✘ ✘ ✘
FXFQ
2-way blow ceiling
mounted cassette ✘ ✘ ✘ ✘ ✘ ✘✘ ✘ ✘
FXCQ
Ceiling mounted
corner cassette ✘✘✘ ✘
FXKQ
Concealed ceiling unit (small)
✘✘
FXDQ
Slim concealed ceiling unit
✘ ✘✘✘✘✘
FXDQ-N
Concealed ceiling unit
✘ ✘ ✘ ✘ ✘ ✘✘ ✘ ✘ ✘
FXSQ
Concealed ceiling unit (large)
✘ ✘ ✘✘ ✘ ✘ ✘✘ ✘
FXMQ
Wall mounted unit
✘ ✘✘✘✘✘ ✘
FXAQ
4-way blow ceiling
suspended unit ✘ ✘✘
FXUQ
Ceiling suspended unit
✘ ✘✘✘✘✘ ✘
FXHQ
Floor standing unit
✘ ✘✘✘✘✘
FXLQ
Concealed floor standing unit
✘ ✘✘✘✘✘
FXNQ
page
14
cooling only

RXQ5M
heat pump

RXYQ5M
P
Possible Outdoor Units
Using R-410A

heat recovery

-
N° of
outdoors

1
N° of
compressors

1
N° of
connectable
indoors

8
Minimum capacity
index*

63
Maximum
capacity

163
index*
Capacity
steps

20
RXQ8M RXYQ8M REYQ8M 1 2 13 100 260 29
RXQ10M RXYQ10M REYQ10M 1 2 16 125 325 29
- RXYQ12M REYQ12M 1 2 19 150 390 29
- RXYQ14M REYQ14M 1 3 20 175 455 35
- RXYQ16M REYQ16M 1 3 20 200 520 35
- RXYQ18M REYQ18M 2 4 20 225 585 41
- RXYQ20M REYQ20M 2 4 20 250 650 41
- RXYQ22M REYQ22M 2 4 22 275 715 41
- RXYQ24M REYQ24M 2 5 32 300 780 46
- RXYQ26M REYQ26M 2 5 32 325 845 46
- RXYQ28M REYQ28M 2 5 32 350 910 46
- RXYQ30M REYQ30M 2 6 32 375 975 51
- RXYQ32M REYQ32M 2 6 32 400 1,040 51
- RXYQ34M REYQ34M 3 7 34 425 1,105 56
- RXYQ36M REYQ36M 3 7 36 450 1,170 56
- RXYQ38M REYQ38M 3 7 38 475 1,235 56
- RXYQ40M REYQ40M 3 8 40 500 1,300 61
- RXYQ42M REYQ42M 3 8 40 525 1,365 61
- RXYQ44M REYQ44M 3 8 40 550 1,430 61
- RXYQ46M REYQ46M 3 9 40 575 1,495 68
- RXYQ48M REYQ48M 3 9 40 600 1,560 68

N° of
N° of N° of Minimum capacity Maximum Capacity
connectable
heat pump heat recovery outdoors compressors index* capacity index* steps
indoors

RWEYQ10M 1 1 16 125 325 *


RWEYQ20M 2 2 20 250 650 *
RWEYQ30M 3 3 32 375 975 *
*Information was not available at time of publication

INDOOR UNIT CAPACITY INDEX

Model 20 25 32 40 50 63 71 80 100 125 200 250


Capacity index 20 25 31.5 40 50 62.5 71 80 100 125 200 250
eg. Selected indoor units: FXCQ25 + FXFQ100 + FXMQ200 + FXSQ40
Connection ratio: 25 + 100 + 200 + 40
= 365
➞ possible outdoor unit RXYQ12M

page
15
M
M a i n
F E A T U R E S

A
A. Creating
Maximum Comfort
1 Inverter technology
The linear VRV system makes use of a variable Proportional Integral
(PI) control system which uses refrigerant pressure sensors to give
added control over inverter and ON/OFF control compressors in
order to abbreviate control steps into smaller units to provide
precise control in both small and larger areas.
This in turn enables individual control of up to 40 indoor units of
different capacity and type at a ratio of 50~130 % in comparison
with outdoor units capacity. 5 HP outdoor units use inverter control
compressors only.

5HP outdoor unit


100%
Compressor Capacity Control

210Hz-52Hz
20 Steps

Inverter
Control

24%
Load
Large Small

8,10,12HP outdoor unit 14,16HP outdoor unit


100% 100%
210Hz-52Hz
Compressor Capacity Control

Compressor Capacity Control

+ No.2 + No.3
N°1
Compressor
Compr. 35 Steps
210Hz-52Hz Inv. Control Inverter Control
N°1
Compressor
+ No.2 Compressor N°3 210-52Hz - 20 steps
Inverter Control 29 Steps Compressor
100% N°1
Operation Compr.
Inv. Control

N°2 Compressor
100% Operation N°2 N°2
N°1 Compressor Compressor N°1
Compressor 100% 100% Compr.
Inverter Control Operation Operation Inv. Control
14% 10%
Load Load
Large Small Large Small

page
16
2 Smart control brings comfort
Cooling An electronic expansion valve, using PID control, continuously
VRV SERIES (DAIKIN PID Controls)
adjusts the refrigerant volume in respond to load variations of the
ON/OFF controlled air conditioner (2.5HP) indoor units. The VRV system thus maintains comfortable room
temperatures at a virtually constant level, without the
Suction air temp.

temperature variations typical of conventional ON/OFF control


systems.

Time

Note: the graph shows the data, measured


in a test room assuming actual heating load.

Keeps temperature stable

Smaller
Slow start-up temperature
The thermostat can control difference
stable room temperature at
± 0.5°C from set point. Large temperature
difference

Startup time reduced


Set point by about 1/3

cles
Non inverter AC co ld cy
and
hot
eats
Rep

Inverter AC

3 Less frequent start/stop cycle


• the technique adopted by Daikin, of regulating the capacity using
multiple compressors clearly results in minimum switching losses
and power surges because of the overlap in capacity and frequency
60% 65%
• since Daikin utilises small 5HP inverter compressors, the influence
Capacity

50%
55% of harmonics is less than that generated by a single large
compressor
• the use of multiple compressors by Daikin also ensures a 50 %
standby facility
30 116 30+on 116+on
Frequency
• smaller compressors are cheaper and faster to replace

page
17
B
B. Energy
Efficient Solution
1 Low running costs
• VRV systems have low running costs because it permits each zone
to be controlled individually. That is, only those rooms that
require air conditioning will be heated or cooled, while the
system can be shut down completely in rooms where no air
conditioning is required.

• VRV units have the highest COP/EER in the market in the most
common operating area

2 Most advanced reluctance brushless


DC compressor technology

The scroll compressor is driven by the newly developed motor,


enabling better performance, higher enery efficiency resulting in
higher energy cost savings.

3 HRV - Heat Reclaim Ventilation System


• Heat and humidity are exchanged between supply and exhaust air,
which
- brings outdoor air close to indoor air conditions
- recovers energy loss
- realises considerable reduction of air conditioning capacity

• The heat exchanger modulates the humidity and


temperature of incoming fresh air to match indoor conditions.

• The balance achieved between indoor and outdoor ambients,


enables the cooling/heating load placed on the air conditioning
system to be reduced. (heat and humidity are exchanged)

• Most energy saving solution as smaller indoor units can be selected :


- size down of indoor units down to 40 %
- payback total VAM system : ±2.5 years*
*conditions : outside cooling conditions : 30°C / outside heating conditions : - 8°C
inside cooling conditions : 24°C / inside heating conditions : 22°C
ventilation per room : 150m3/h

• Ideal modular concept to cope with the fresh air requirements

4 Auto restart capability


Even after exceptionally long power failures, the built-in auto restart
capability ensures automatic system start up. Since the preset memory
is not erased by interruptions in power supply, no programme
resetting is necessary.

page
18
5 Low operation sound level
• Continuous research by Daikin into reducing operation sound
levels has resulted in the development of a purpose designed
inverter scroll compressor and fan.

• The new grille and fan offer low noise, high volume airflow and
are housed in a compact casing together with the associated
compressor components. The use of this new technology assembly
enables a 16hp unit to be housed in a single casing.

Aero spiral fan:


Bending the fan blade edge reduces turbulence, resulting in less
pressure loss

Aero fitting grille:


New shape promotes spiral discharge airflow, resulting in reduced
pressure loss

• Night quiet function (max. -8dBA)


Capability %
100 During night time, sound level of the outdoor unit can be reduced
for a certain period : starting time and ending time can be input
50
Load %

0
58
Operation Night mode
sound dBA Night
Max. - 8dBA(10HP) mode
50 ends

8:00 12:00 16:00 20:00 0:00 4:00 8:00


Night mode starts external signal input
to outdoor PCB
Notes :
• This function is available in setting at site.
• The relationship of outdoor temperature (load)
and time shown in the graph is just an example.

Water-cooled air conditioning can be acceptable in certain critical


areas in which the operating sound of air-cooled air conditioning
could be a little intrusive. This results from:
- the low operating sound level of the condensing unit
- indoor installation capabilities of the unit
- custom engineered sound level of the dry cooler

• Daikin indoor units have very low sound operation levels,


down to 25 dBA.

dB(A) Perceived loudness Sound

0 Treshold of hearing -
20 Extremely soft Rustling leaves
40 Very soft Quiet room
Daikin indoor units
60 Moderately loud Normal conversation
80 Very loud City traffic noise
100 Extremely loud Symphonic orchestra
120 Threshold of feeling Jet taking off

page
19
B
B. Energy
Efficient Solution
6 Operation range of outdoor temperature

• Standard operation down to -20°C outdoor ambient temperature


Advanced PI control of the outdoor unit enables VRVII heat
recovery and Inverter cooling only/heat pump series to operate at
outdoor ambients down to -5°C in cooling mode and down to
-20°C in heating mode.

50 50
Cooling Cooling
43°CDB 43°CDB
40 40

30 30

Cooling & Heating Heating


20 20 15.5°CWB 15.5°CWB
Heating
15.5°CWB
10 10

-5 -5
-5°CDB -5°CDB -5°CWB

-10 -10

-15 -15

-20 -20
-20°CWB -20°CWB

Inverter cooling only Heat recovery


heat pump

• Wide operating range of the water-cooled units between 10°C &


45°C, both in cooling and heating.

50
Cooling Heating
45°C 45°C
40

30

20

10
10°C 10°C

page
20
C
C. High
Reliability
1 N°1 anti-corrosion treatment
• Special anti corrosion treatment of the heat exchanger provides
5 to 6 times greater resistance against acid rain and salt corrosion.
The provision of rust proof steel sheet on the underside of
the unit gives additional protection.

Improvement in corrosion resistance


Corrosion resistance rating

Non-treated Anti-corrosion treated


Salt corrosion 1 5 to 6
Acid rain 1 5 to 6

An anti-corrosion heat exchanger


cutaway view

Hydrophilic film
Aluminium
Corrosion-resistant
Heat exchanger Acrylic resin

Performed tests :
8
VDA Wechseltest
Corrosion resistance

6
contents of 1 cycle (7 days):
• 24 hours salt spray test 4

SS DIN 50021 2

• 96 hours humidity cycle test 0


1 2 3 4 5
KFW DIN 50017 Cycle

• 48 hours room temperature


& room humidity
testing period : 5 cycles Bare
aluminium

DAIKIN P.E.
10
Kesternich test (SO2) 9
• contents of 1 cycle (48 hours) 8
according to DIN50018 (0.21)
Corrosion resistance

7
• testing period : 40 cycles 6
5
4
3
2
1
0
1 2 3 4 5 6 10 20 30 40
Cycle

page
21
C
C. High
Reliability
2 Double back-up function
In the event of a compressor malfunction, the remotely controlled
or field set back-up function in the outdoor unit in question
(and also between different outdoor units) will allow emergency
operation of another compressor in order to maintain 8 hour
maximum interim capacity

3 Duty cycling
The cyclical start-up sequence of multiple outdoor unit systems
equalises compressor duty and extends operating life.

4 Special oil equalising technology


The incorporation of this technology ensures that the optimum
quantity of oil is contained in each outdoor unit module in order
to maintain compressor reliability. Automatic checks are carried
out every 6 minutes on the number of compressors in operation
and also to ascertain that there is enough oil to keep them running.

Each compressor in a VRVII outdoor unit is equipped with an


internal oil equalising circuit, comprising an oil separator and oil
return circuit. This ensures that the maximum quantity of oil is
returned to the compressor case before entering the REFNET piping
network.

page
22
D
D. Eco
Friendly
1 Lowest refrigerant amount in
the total system
18 HP Comparable VRF system

Total refrigerant amount 100% 160 %


in the system*
* based on average installation

2 Dramatic reduction in initial


refrigerant charge :
on
ucti
Red .5% 16 HP R-22 R-407C R-410A
0
of 2
VRV-K series VRV-K series series

Refrigerant charge 100 % 85.6 % 79.5 %

3 Optimised R-410A design

Daikin Europe has achieved a quantum leap forward in commercial


air conditioning technology by the introduction of its VRVII, the
world’s first R-410A operated variable refrigerant flow system.
Available in cooling only, heat pump and heat recovery versions, the
new system, which represents a considerable advance over earlier
VRV systems, demonstrates Daikin’s innovative application of new
technology and the latest HFC refrigerants to its VRV product
programmes.

4 Less waste and improved re-cycling

The lead free, soldered PCB obviates environmental contamination,


whilst the recyclable galbarium steel bottom plate is designed to
last around 6 times longer than the traditional galvanised base.

5 Refrigerant recovery function


The refrigerant recovery function enables all expansion valves to
be opened. In this way the refrigerant can be drained from
the piping system and stored in the receiver and the condenser.

page
23
1 Total room layout
E
E. Easy and
Flexible Design

Meeting room
Meeting room
INDOOR UNIT
ADDITION


Meeting room
flexibility Reception room

Stock room
• VRVII systems are easily
adaptable to changes in
room layout : extra indoor
units can be added to a
VRV outdoor unit up to a


capacity level of 130%.
Office
• Also, since VRVII heat recovery Office

systems offer simultaneous Meeting room


cooling and heating, existing ROOM LAYOUT CHANGE
indoor and outdoor units can
continue to provide year
round air conditioning from
their existing locations, even
if office layouts are altered or 2 Complete flexibility
extended.
• The VRVII / VRV-WII systems enables different floors or even rooms
to be rented to different customers, because each room has
independent control of its air conditioning.
• Thanks to inverter technology, as many as 40 indoor units
(32 indoor units for VRV-WII) with different types and capacities
can be installed in one system. This system automatically and
effectively controls each unit to provide individual rooms of
different sizes with a comfortable working or living environment.

3 Year round cooling and/or heating


• Designed to provide simultaneous year round cooling and/or
heating, VRVII heat recovery systems are modular in concept
and are therefore, ideal for use in rooms or zones that generate
varying thermal loads according to building orientation or local
hot or cold spots.
• It is possible for the same meeting room to give rise to differing
thermal loads depending on the time of day, number of occupants
present, location and usage pattern of lighting and electronic
office equipment.
• Until the advent of the VRV, a complex 4-pipe fan coil was needed
to meet this requirement. The VRV however, is easier to design
and install and in its heat recovery format, can conserve energy in
two or more rooms at the same time.
• The colder it is outside, the warmer it needs to be indoors, which
means that the capacity of the air-cooled outdoor unit drops.
Water-cooled air conditioners are not subject to this problem.
The boiler ensures that sufficient enough additional heat is always
available indoors.

page
24
4 Longest refrigerant piping run
• The ability to sustain refrigerant piping in lengths up to 150m
(175m equivalent), allows systems to be designed with level
differences of 50m between indoor and outdoor units and 15m
between individual indoor units. Thus, even with installations in
15 storey buildings, all outdoor units can be located at rooftop
level.

g
ipin
c t u al p 0 m
A 5
th 1
leng
Actual piping
length
*1

Level difference between


indoor and outdoor units
ing
t pip
u i v alen 75 m
Eq th 1
Level difference
between indoor leng
units

piping length
between first branch
and furthest indoor
units

*1 in this case the outdoor unit is located


above the indoor unit. If the outdoor
unit is located underneath the indoor
unit the level difference is a maximum
of 40m.

• The water-cooled VRV-WII, uses water as its heat source and since
there are no limitations on water piping length, is eminently
suitable for application to tall multi storey or large buildings.
Considerable flexibility is available within the refrigerant circuit
since up to 120m actual piping length and 50m* (if the VRV-WII is
above the indoor units) in height can exist between the VRV-WII
and indoor units. Water piping does not intrude on the occupied
spaces, so there are no leakage problems.

* 40m if the VRV-WII is below the indoor units.

Actual piping length Water piping


between the VRV-WII and indoor units: 120m
(Equivalent piping length: 140m) Refrigerant piping
(Total piping length: 300m)

g
ipin
Level difference
between indoor units: 15m c t u al p 0 m
A 2
th 1
Level difference leng
between the VRV-WII
and indoor units:
50m if the VRV-WII is above
40m if the VRV-WII is below

ng
pipi
i v a lent 0 m
Equ gth 14
Indoor installation len
VRV-WII

Water piping length depends on the heat source equipment

page
25
E
E. Easy and
Flexible Design
5 VRV Pro selection programme
A simple to use, Daikin computerised selection programme, designed
for use with Windows 95®, Windows 98® and WindowsNT® systems,
enables consulting engineers, design and build contractors, property
developers and architects etc. to plan a Daikin air conditioning
project on a step by step basis, complete with detailed drawings,
bills of quantities and costs.
The programme thus enables VRV air conditioning systems to be
engineered precisely and economically (without over-sizing units),
thereby ensuring optimum operating cycles and maximum energy
efficiency.

Features :

• the VRV Pro selection programme offers 3 separate modes to


accommodate different design formats according to customer
requirements. Multi languages are possible.

1. Expert mode :
once the cooling and heating loads in the different rooms have
been calculated, the software will select the most appropriate
system plus an estimate of the power consumption

2. Quick mode :
based on calculated system loads, the software will select the most
appropriate system

3. Drawing mode :
selecting the indoor and outdoor units from a list enables the user
to design a system in no time at all

• AutoCAD and scanned drawings can be used to help draw up a


floor plan
• piping diameters can be automatically calculated
• indoor and outdoor units, headers and joints etc can be
automatically selected

Windows95®, Windows98® and WindowsNT® are registered trademarks of Microsoft corporation.

6 VRV Xpress
This new super rapid response VRV selection tool is easy to
understand, easy to use and enables automated piping and wiring
diagrams of up to 3MB to be transmitted via e mail. The package
comes complete with single file software and update, requires no
installation or drawings and is available in multi language options.

page
26
F
F. S i m p l e a n d R a p i d
Installation
1 Short installation time
• Thanks to small bore refrigerant pipes and REFNET piping options,
the VRVII / VRV-WII piping system can be installed very easily and
quickly.
• Installation of the VRVII / VRV-WII system can also be implemented
floor by floor, so that sections of the building can be put into use
very quickly, or enabling the air conditioning system to be
commissioned and operated in stages, rather than on final
Installation space (16 HP) completion of the project.
3.56 m2 ➞ 1.88 m2

Approx.
50%
reduction

RSXYP 2 Dramatic reduction in installation space


• VRVII features a dramatic reduction in installation space - for
example, the 16hp outdoor unit is housed in a single casing
outdoor unit, providing a 50 % reduction in required installation
space.
• The adoption of a new water heat exchanger and optimization of
the refrigerant control circuit has resulted in the industry’s most
compact and lightweight design. The unit weight of 150kg and
Stacked configuration is possible. (Ceiling height)
height of 1,000mm makes installation easy. Stacked configuration
is also possible, contributing further to space savings.
3200mm
or higher

(Floor level)

(100-300mm)

3 Modular & lightweight


• Modular design enables units to be joined together in rows with
an outstanding degree of uniformity.
• The design of the outdoor units is sufficiently compact to allow
them to be taken up to the top of a building in a commercial
elevator, overcoming site transportation problem, particularly
when outdoor units need to be installed on each floor.

10HP
Reduction
of 42%
Weight reduction 100 % 84 % 58 %

page
27
F
F. S i m p l e a n d R a p i d
Installation
4 No structural reinforcement necessary
• The galbarium steel allows the use of block foundations -
earlier VRV K and L systems required full beam foundations.
• Thanks to the lightweight and vibration-free construction of the
outdoor units, floors do not need to be reinforced, reducing the
overall cost of the building.

RSXYP10K RXYQ16M

5 Unified REFNET piping


• The unified Daikin REFNET piping system is especially designed
REFNET joint Attached insulators for
REFNET joint for simple installation
• The use of REFNET piping in combination with electronic expansion
valves, results in a dramatic reduction in imbalance in refrigerant
flowing between indoor units, despite the small diameter of the
REFNET header Attached insulators piping.
for REFNET header
• REFNET joints and headers (both accessories) can cut down on
installation work and increase system reliability.
• Compared to regular T-joints, where refrigerant distribution is far
from optimal, the Daikin REFNET joints have specifically been
REFNET joint T-joint designed to optimise refrigerant flow.

6 Increased installation flexibility


Duct Duct Outdoor units can be installed far back from former location.

Current

7 High external static pressure : 6mm H2O


Daikin now offers high external static pressure as standard to meet
requirements of indoor installation.

8 4-way piping connection


VRVII / VRV-WII series not only offer the possibility to run piping
from the front, but also from the left, right or bottom, thus
providing greater freedom of layout.

Front

Bottom
Left Right

page
28
9 Downsizing refrigerant piping

• Reduced piping diameters

Use of high efficiency R-410A enables the VRVII to operate on a


smaller refrigerant charge to be used, leading to a reduction in
liquid and gas pipe diameters.

• Reduced piping costs thanks to modular


design

Smaller diameter liquid and gas piping contributes to a reduction in


installation space and installation costs.
0.51 m2 0.29 m2
1,700 x 300 950 x 300
based on a 240HP installation
Standard VRV System
Outdoor unit Indoor units (max. 16 units)

System
➔ Around 30%
reduction in
installation
costs for
refrigerant piping.

Outdoor unit Indoor units (max. 40 units)

System
Indoor units (max. 32 units)

R-410A

H2O

page
29
F
F. S i m p l e a n d R a p i d
Installation
10 Sequential start
Up to 3 outdoor units can be connected to 1 power supply and can
be turned on sequentially. This allows the number of breakers and
their capacities to remain small and simplifies wiring (for models of
10Hp or less).

11 Self diagnosis
Detects malfunctions in major locations of the system and displays
the type of malfunction and location, which in turn allows servicing
and maintenance to be performed more efficiently.

12 Crosswiring check
The cross wiring check facility available on the VRVII is the first of its
type in the industy to warn operatives of connection errors in
interunit wiring and piping. This function identifies and alerts
system errors by means of on/off LEDs on the outdoor unit’s PC
boards.

13 Simplified wiring
• A simple 2-wire non-shielded multiplex transmission system links
each outdoor unit to multiple indoor units using one 2-core wire,
thus simplifying the wiring operation.
• Furthermore, outdoor units have power connection outlets on
side and front, resulting in easier installation and maintenance
and saving space when rows of units are connected together.

page
30
14 “Super Wiring” system
• A Super Wiring system is used to enable the shared use of wiring
between indoor units, outdoor units and the centralised remote
control.
• This system makes it easy for the user to retrofit the existing
system with a centralised remote control, simply by connecting it
to the outdoor units.
• Thanks to a non polarity wiring system, incorrect connections
become impossible and installation time is reduced.

15 4-way wiring connection


Wiring can be fed from the front panel, both left and right side
panels or bottom panel of the outdoor unit.

Left

Right

Bottom
Front

16 Auto address setting function


Allows wiring between indoor and outdoor units, as well as group
control wiring of multiple indoor units, to be performed
without the bothersome task of manually setting each address.

page
31
P
Product Features
O U T D O O R U N I T S
S
Survey
&

5-8-10
Inverter cooling only
Units

RXQ-M p. 37

8,10HP

Inverter heat pump


5-8-10-12-14-16-18-20-22-24-26-28-30-32-34-36-38-40-42-44-46-48

RXYQ-M p. 38

12,14,16HP

Heat recovery
8-10-12-14-16-18-20-22-24-26-28-30-32-34-36-38-40-42-44-46-48

REYQ-M p. 40

28,30,32HP

Inverter heat pump


10-20-30

RWEYQ-M p. 43

10HP

Heat recovery
10-20-30

RWEYQ-M p. 43

10HP

All VRVII units have standard treatment against corrosion(*).

(*) Note: for extremely corrosive environmental conditions, additional precautions have to be taken.

page
33
Te c h n o l o g y
Iron
N
1 Reluctance brushless
N DC compressor
S Rotating
S N N S Stator
S
Field
N • The reluctance brushless DC motor provides significant increases
S in efficiency compared to conventional AC inverter motors,
“Normal” torque

Neodymium
Reluctance torque simultaneously using 2 different forms of torque (normal and
Magnet reluctance torque) to produce extra power from small electric
Suction currents.
• The motor comprises powerful neodymium
Low pressure
Scroll magnets, that create the reluctance torque.
side
These magnets are approximately 12 times
Discharge
stronger than ferrite magnets and make a major Ferrite
magnet
High pressure
contribution to its energy saving characteristics.
Reluctance
side DC Motor Neodymium magnet

NEW • High thrust mechanism (VRVII cooling only/heat pump)


By introducing high pressure oil, the reactive force from the fixed
scroll is added to the internal force, thereby reducing thrust losses.
This results in improved efficiency and suppressed sound level

2 Sine Wave DC
inverter

Optimizing the sine wave


curve, results in smoother motor
rotation and improved motor
efficiency.

3 DC fan motor
DC fan motor structure

The use of a DC fan motor offers


substantial improvements in
operating efficiency compared to
conventional AC motors, especially
during low speed rotation.

DC motor efficiency
(comparison with a conventional AC motor)
100

80
Efficiency (%)

60

40
AC motor
20

0
200 300 400 500 600 700 800 900 1000
page Motor speed (rpm)
34
4 Aero fitting grille & aero spiral fan
These features achieve a low noise fan with a large airflow, and
realize a compact casing together with the compressor linking
technology.

Aero spiral fan Aero fitting grille


Bending the fan blade New shape promotes a
edge reduces turbulence, spiral discharge airflow,
resulting in less pressure resulting in reduced
loss. pressure loss.

5 e-Pass heat exchanger


Optimization of the path layout Current Model HD Type
of the heat exchanger prevents
heat transferring from the
overheated gas section towards IN 85°C
OUT 45°C
IN 85°C
OUT 45°C

the sub cooled liquid section - a 27°C 55°C 55°C 27°C 37°C 43°C

more efficient use of the heat 27°C 55°C 27°C 60°C

exchanger. 27°C 50°C 27°C 55°C

OUT 45°C

In cooling mode, the heat exchanger of the


4 condensor is improved. This means an improvement
of COP by 3%.

2
6 i-Demand function
5
The newly introduced current sensor
consumption (KVV)

minimizes the difference between


1
Power

the actual power consumption and


the predefined power consumption.
8:00 12:00 16:00 20:00
Time

No oil equalising piping


necessary for VRVII
7 Compact aero box
cooling only / heat pump
series Lower noise and savings in input power are achieved by stacking
the inverter and control PCBs within a new and more compact
‘aero’ box.

page
35
Line-up

5HP 8-10HP 12-14-16HP

18-20HP 34-36HP

22-24-26HP 38-40-42HP

28-30-32HP 44-46-48HP

page
36
RXQ-M9 COOLING ONLY

NEW

VRVII COOLING ONLY RXQ5M9W1B RXQ8M9W1B RXQ10M9W1B


Equivalent horsepower HP 5 8 10
Number of outdoor units 1 1 1
Number of connectable indoor units 8 13 16
Minimum capacity index 62.5 100 125
Maximum capacity index 162.5 260 325
Capacity steps 20 29 29
Nominal cooling capacity kW 14.0 22.4 28.0
Power input kW 4.14 5.92 8.01
COP 3.38 3.78 3.50
Power supply W1 3N~, 50Hz, 400V
Dimensions Height mm 1,600 1,600 1,600
Width mm 635 930 930
Depth mm 765 765 765
Weight kg 141 219 219
Colour ivory white
Sound pressure levels dB(A) 54 57 58
Sound power level dB(A) 72 78 78
Fan Type propeller fan
Air flow rate m3/h 4,500 10,500 10,800
Refrigerant Name R-410A
Charge kg 5.6 7.6 8.6
Control electronic expansion valve
Refrigerant oil Type synthetic (ether) oil
Charge l 1.7 1.6+1.7+2 1.6+1.7+2
Compressor Type hermetically sealed scroll type
Number of compressors 1 2 2
Starting method direct on line
Piping connections Liquid mm 9.5 fl 9.5 fl 9.5 fl
Gas mm 15.9 fl 19.1 br 22.2 br
Safety devices high pressure switch, fan motor driver overload protector, inverter overload protector, overcurrent relay (for 8, 10HP), PCB fuse

Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB
outdoor temperature: 35°CDB
equivalent refrigerant piping: 7.5m
level difference: 0m
• Sound power level is an absolute value that a sound source generates.
• Sound pressure level is a relative value, depending on the distance and acoustic environment.
• Sound values are measured in a semi-anechoic room.

page
37
NEW HEAT PUMP

VRVII HEAT PUMP RXYQ5M9W1B RXYQ8M9W1B RXYQ10M9W1B RXYQ12M9W1B RXYQ14M9W1B RXYQ16M9W1B


Nominal cooling capacity kW 14.0 22.4 28.0 33.5 40.0 45.00
Nominal heating capacity kW 16.0 25.0 31.5 37.5 45.0 50.0
Power input Cooling kW 4.14 5.92 8.01 9.16 13.40 16.00
Heating kW 3.71 6.06 7.65 9.20 11.70 13.20
COP Cooling 3.38 3.78 3.50 3.66 2.99 2.78
Heating 4.31 4.13 4.12 4.08 3.85 3.79
Power supply W1 3N~, 50Hz, 400V
Dimensions Height mm 1,600 1,600 1,600 1,600 1,600 1,600
Width mm 635 930 930 1,240 1,240 1,240
Depth mm 765 765 765 765 765 765
Weight kg 146 217 217 240 289 289
Colour ivory white
RXYQ-M9
Sound pressure levels dB(A) 54 57 58 60 60 60
Sound power level dB(A) 72 78 78 80 80 80
Fan Type propeller fan
Air flow rate 4,500 10,500 10,800 12,600 12,600 12,600
Refrigerant Name R-410A
Charge kg 5.6 7.6 8.6 10.4 11.6 12.4
Control electronic expansion valve
Refrigerant oil Type synthetic (ether) oil
Charge l 1.7 1.6+1.7+2 1.6+1.7+2 1.6+1.7+2 1.7+(2x1.6)+3.2 1.7+(2x1.6)+3.2
Compressor Type hermetically sealed scroll type
Starting method direct on line
Piping connections Liquid mm 9.5 fl 9.5 fl 9.5 fl 12.7 fl 12.7 fl 12.7 fl
Gas mm 15.9 fl 19.1 br 22.2 br 28.6 br 28.6 br 28.6 br
Safety devices high pressure switch, fan motor driver overload protector, inverter overload protector, overcurrent relay (for 8-16HP), PCB fuse

Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB
outdoor temperature: 35°CDB
equivalent refrigerant piping: 7.5m
level difference: 0m
• Nominal heating capacities are based on: indoor temperature: 20°CDB
outdoor temperature: 7°CDB/6°CWB
equivalent refrigerant piping: 7.5m
level difference: 0m
• Sound power level is an absolute value that a sound source generates.
• Sound pressure level is a relative value, depending on the distance and acoustic environment.
• Sound values are measured in a semi-anechoic room.

RXYQ-M9 5 8 10 12 14 16 18 20
Modules RXYQ5M 1
RXYQ8M 1 1
RXYQ10M 1 1 2
RXYQ12M 1
RXYQ14M 1
RXYQ16M 1
Equivalent horsepower HP 5 8 10 12 14 16 18 20
Number of outdoor units 1 1 1 1 1 1 2 2
Number of compressors 1 2 2 2 3 3 4 4
Number of connectable indoor units 8 13 16 19 20 20 20 20
Minimum capacity index 62.5 100 125 150 175 200 225 250
Maximum capacity index 162.5 260 325 390 455 520 585 650
Cooling capacity kW 14.0 22.4 28.0 33.5 40.0 44.5 50.4 56.0
Heating capacity kW 16.0 25.0 31.5 37.5 45.0 50.0 56.5 63.0
Power input Cooling kW 4.14 5.92 8.01 9.16 13.40 16.00 13.93 16.02
Heating kW 3.71 6.06 7.65 9.20 11.70 13.20 13.71 15.30
COP Cooling 3.38 3.78 3.50 3.66 2.99 2.78 3.62 3.50
Heating 4.31 4.13 4.12 4.08 3.85 3.79 4.12 4.12
Capacity steps 20 29 29 29 35 35 41 41
Dimensions Height mm 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600
Width mm 635 930 930 1,240 1,240 1,240 1,860 1,860
Depth mm 765 765 765 765 765 765 765 765
Weight kg 146 217 217 240 289 289 434 434

page
38
RXYQ-M9

22 24 26 28 30 32 34 36 38 40 42 44 46 48

1 1 1 2 2 1 1 1
1 1 1 1
1 1 1 1 1
1 1 1 2 1 1 1 2 2 2 3
22 24 26 28 30 32 34 36 38 40 42 44 46 48
2 2 2 2 2 2 3 3 3 3 3 3 3 3
4 5 5 5 6 6 7 7 7 8 8 8 9 9
22 32 32 32 32 32 34 36 38 40 40 40 40 40
275 300 325 350 375 400 425 450 475 500 525 550 575 600
715 780 845 910 975 1,040 1,105 1,170 1,235 1,300 1,365 1,430 1,495 1,560
61.5 68.0 72.5 78.0 84.5 89.0 96.0 101 106.0 113 117.0 123 129.0 134
69.0 76.5 81.5 87.5 95.0 100.0 108.0 113.0 119.0 127 132 138 145.0 150.0
17.20 21.40 24.00 25.20 29.40 32.00 29.40 32.00 33.20 37.40 40.00 41.20 45.40 48.00
16.90 19.40 20.90 22.40 24.90 26.40 27.00 28.50 30.10 32.60 34.10 35.60 38.10 39.60
3.58 3.18 3.04 3.12 2.89 2.81 3.27 3.16 3.21 3.02 2.95 3.00 2.86 2.81
4.08 3.94 3.90 3.91 3.82 3.79 4.00 3.96 3.95 3.88 3.86 3.86 3.81 3.79
41 46 46 46 51 51 56 56 56 61 61 61 68 68
1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600
2,170 2,170 2,170 2,480 2,480 2,480 3,100 3,100 3,410 3,410 3,410 3,720 3,720 3,720
765 765 765 765 765 765 765 765 765 765 765 765 765 765
457 506 506 529 578 578 723 723 746 795 795 818 867 867

page
39
HEAT RECOVERY

REYQ-M7W1B 8 10 12 14 16
Nominal cooling capacity kW 22.4 28.0 33.5 40.0 44.5
Nominal heating capacity kW 25.0 31.5 37.5 45.0 50.0
Power input Cooling kW 6.97 9.00 10.60 14.24 15.60
Heating kW 6.89 9.31 10.80 12.90 14.0
COP Cooling 3.21 3.11 3.16 2.81 2.85
Heating 3.63 3.38 3.47 3.49 3.57
Power supply W1 3~, 50Hz, 380-415V
Dimensions Height mm 1,600 1,600 1,600 1,600 1,600
Width mm 930 930 1,240 1,240 1,240
Depth mm 765 765 765 765 765
Weight kg 245 245 295 340 340
Colour ivory white (5Y7.5/1)
Sound pressure levels dB(A) 57 58 60 60 60
Sound power level dB(A) 78 78 80 80 80
REYQ-M7
Fan Type propeller fan
Air flow rate 10,500 10,800 12,600 12,600 12,600
Refrigerant Name R-410A
Charge kg 10.3 11.4 12.4 13.5 14.6
Control electronic expansion valve
Refrigerant oil Type synthetic (ether) oil
Charge l 1.9+1.6 1.9+1.6 1.9+1.6 1.9+1.6+1.6 1.9+1.6+1.6
Compressor Type hermetically sealed scroll type
Starting method direct on line
Piping connections Liquid mm 9.5 fl 9.5 fl 12.7 fl 12.7 fl 12.7 fl
Gas mm 19.1 br 22.2 br 28.6 br 28.6 br 28.6 br
Discharge gas mm 15.9 br 19.1 br 19.1 br 22.2 br 22.2 br
Safety devices high pressure switch, fan driver overload protector, overcurrent relay, inverter overload protector, fusible plugs

Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB
outdoor temperature: 35°CDB
equivalent refrigerant piping: 7.5m
level difference: 0m
• Nominal heating capacities are based on: indoor temperature: 20°CDB
outdoor temperature: 7°CDB/6°CWB
equivalent refrigerant piping: 7.5m
level difference: 0m
• Sound power level is an absolute value that a sound source generates.
• Sound pressure level is a relative value, depending on the distance and acoustic environment.
• Sound values are measured in a semi-anechoic room.

REYQ-M7W1B 8 10 12 14 16 18 20
Modules REYQ8M 1 1
REYQ10M 1 1 2
REYQ12M 1
REYQ14M 1
REYQ16M 1
Equivalent horsepower HP 8 10 12 14 16 18 20
Number of outdoor units 1 1 1 1 1 2 2
Number of compressors 2 2 2 3 3 4 4
Number of connectable indoor units 13 16 19 20 20 20 20
Minimum capacity index 100 125 150 175 200 225 250
Maximum capacity index 260 325 390 455 520 585 650
Cooling capacity kW 22.4 28.0 33.5 40.0 44.5 50.4 56.0
Heating capacity kW 25.0 31.5 37.5 45.0 50.0 56.5 63.0
Power input Cooling kW 6.97 9.00 10.60 14.24 15.60 16.00 18.00
Heating kW 6.89 9.31 10.80 12.90 14.0 16.50 19.00
COP Cooling 3.21 3.11 3.16 2.81 2.85 3.15 3.11
Heating 3.63 3.38 3.47 3.49 3.57 3.42 3.32
Capacity steps 29 29 29 35 35 41 41
Dimensions Height mm 1,600 1,600 1,600 1,600 1,600 1,600 1,600
Width mm 930 930 1,240 1,240 1,240 1,860 1,860
Depth mm 765 765 765 765 765 765 765
Weight kg 245 245 295 340 340 490 490

page
40
BSVQ-MV1
Power supply
REYQ-M7
Total capacity of connectable indoor units
Maximum number of connectable indoor units
Casing
V1
100

x ≤ 100
5
160
1~, 220-240V, 50Hz
100 < x ≤ 160
8
galvanised steel plate
250

160 < x ≤ 250


5

Dimensions Height mm 185 185 185


Width mm 310 310 310
Depth mm 280 280 280
Weight kg 9 9 10
Piping connections indoor unit Liquid mm 9.5 flare 9.5 flare 9.5 flare
Gas mm 15.9 flare 15.9 flare 22.2 flange
outdoor unit Liquid mm 9.5 flare 9.5 flare 9.5 flare
Suction gas mm 15.9 flare 15.9 flare 22.2 flange
Discharge gas mm 12.7 flare 12.7 flare 19.1 flare
Safety devices PCB fuse

22 24 26 28 30 32 34 36 38 40 42 44 46 48

1 1 1 2 2 1 1 1
1 1 1 1
1 1 1 1 1
1 1 1 2 1 1 1 2 2 2 3
22 24 26 28 30 32 34 36 38 40 42 44 46 48
2 2 2 2 2 2 3 3 3 3 3 3 3 3
4 5 5 5 6 6 7 7 7 8 8 8 9 9
22 32 32 32 32 32 34 36 38 40 40 40 40 40
275 300 325 350 375 400 425 450 475 500 525 550 575 600
715 780 845 910 975 1,040 1,105 1,170 1,235 1,300 1,365 1,430 1,495 1,560
61.5 68.0 72.5 78.0 84.5 89.0 96.0 101.0 106.0 113 117.0 123 129.0 134
69.0 76.5 81.5 87.5 95.0 100.0 108.0 113.0 119.0 127 132 138 145.0 150.0
19.60 23.24 24.60 26.20 29.90 31.20 32.20 33.60 35.20 38.90 40.20 41.80 45.50 46.90
20.50 22.60 23.80 25.30 27.50 28.60 32.10 33.30 34.80 37.00 38.10 39.60 41.80 42.90
3.14 2.92 2.95 2.98 2.83 2.85 2.98 3.01 3.01 2.90 2.91 2.94 2.84 2.86
3.36 3.38 3.42 3.46 3.45 3.50 3.36 3.39 3.42 3.43 3.46 3.48 3.47 3.50
41 46 46 46 51 51 56 56 56 61 61 61 68 68
1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600
2,170 2,170 2,170 2,480 2,480 2,480 3,100 3,100 3,410 3,410 3,410 3,720 3,720 3,720
765 765 765 765 765 765 765 765 765 765 765 765 765 765
540 585 585 635 680 680 830 830 880 925 925 975 1,020 1,020

page
41
Te c h n o l o g y

Iron
N
1 Reluctance brushless
N DC compressor
S Rotating
S N N S Stator
S
Field
N • The reluctance brushless DC motor provides significant increases
S in efficiency compared to conventional AC inverter motors,
“Normal” torque

Neodymium
Reluctance torque simultaneously using 2 different forms of torque (normal and
Magnet reluctance torque) to produce extra power from small electric
currents.
Suction NEW • High thrust mechanism
By introducing high pressure oil, the reactive force from the fixed
Low pressure
Scroll scroll is added to the internal force, thereby reducing thrust losses.
side
This results in improved efficiency and suppressed sound level
Discharge
• The motor comprises powerful neodymium magnets, that create
High pressure
the reluctance torque. These magnets are approximately 12 times
Reluctance
side DC Motor stronger than ferrite magnets and make a major contribution to
its energy saving characteristics.

Ferrite
magnet

Neodymium magnet

2 Sine Wave DC
inverter

Optimizing the sine wave


curve, results in smoother
motor rotation and
improved motor efficiency.

2 1

3 i-Demand function
consumption (KVV)

The newly introduced current sensor


Power

minimizes the difference between


the actual power consumption and
8:00 12:00 16:00 20:00 the predefined power consumption.
Time

page
42
VRV-WII
RWEYQ HEAT PUMP
RWEYQ10MY1 RWEYQ20MY1 RWEYQ30MY1 RWEYQ10MY1 RWEYQ20MY1
HEAT PUMP
HEAT RECOVERY

HEAT RECOVERY
RWEYQ30MY1
Nominal cooling capacity kW 26,70 53,40 80,10 26,70 53,40 80,10
Nominal heating capacity kW 31,50 63,00 94,50 31,50 63,00 94,50
Capacity range HP 10 20 30 10 20 30
Power input (nominal) Cooling kW 6,03 12,10 18,10 6,03 12,10 18,10
Heating kW 6,05 12,10 18,20 6,05 12,10 18,20
COP Cooling 4,43 4,41 4,43 4,43 4,41 4,43
Heating 5,21 5,21 5,19 5,21 5,21 5,19
Max n° of indoor units to be connected 16 20 32 16 20 32
Minimum capacity index 125 250 375 125 250 375
Maximum capacity index 325 650 975 325 650 975
Power supply Y1 3~, 50Hz, 380-415V 3~, 50Hz, 380-415V
Dimensions Height mm 1000 * * 1000 * *
Width mm 780 * * 780 * *
Depth mm 550 * * 550 * *
Weight kg 150 150+150 150+150+150 150 150+150 150+150+150
Colour Ivory white (5Y7,5/1) Ivory white (5Y7,5/1)
Sound pressure levels dBA 51.0 54.0 56.0 51.0 54.0 56.0
Sound power levels dBA ** ** ** ** ** **
Fan Type ** ** ** ** ** **
Air Flow Rate (nominal) m3/min ** ** ** ** ** **
Refrigerant Name R-410A R-410A
Charge kg 5.2 5.2+5.2 5.2+5.2+5.2 5.2 5.2+5.2 5.2+5.2+5.2
Control Expansion valve (electronic type) Expansion valve (electronic type)
Refrigerant Oil Type Synthetic (ether) oil Synthetic (ether) oil
Charged Volume l ** ** ** ** ** **
Compressor Quantity 1 2 3 1 2 3
Type Hermetically sealed scroll compressor Hermetically sealed scroll compressor
Starting method Soft start Soft start
Piping Connections Liquid mm 9.52 (flare) 15.9 (flare) 19.1 (flare) 9.52 (flare) 15.9 (flare) 19.1 (flare)
Discharge gas mm 22.2 (brazing) 28.6 (brazing) 34.9 (brazing) 19.1 (brazing) 22.2 (brazing) 28.6 (brazing)
Gas mm - - - 22.2 (brazing) 28.6 (brazing) 34.9 (brazing)
Safety devices HPS, inverter overload protector, fusible plugs HPS, inverter overload protector, fusible plugs

Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • inlet water temperature: 30°C • equivalent refrigerant piping: 7.5m • level difference: 0m
• Nominal heating capacities are based on: indoor temperature: 20°CDB • inlet water temperature: 20°C • equivalent refrigerant piping: 7.5m • level difference: 0m
• This unit should not be installed outdoors, but indoors eg. in a machine room, etc.
• Indoor operating ambient temperature: 0 ~ 40°C. Heat rejection from the outdoor unit: 0,71kW/10HP
• *Dimensions of 20HP and 30HP units depend on the method of stacking
• **Data were not available at the time of publication

page
43
ACCESSORIES

RXQ-M9 5 8 10
Fixing box KJB111A
Refnet header KHRQ22M29H KHRQ22M29H7

KHRQ22M20T
Refnet joint KHRQ22M20T
KHRQ22M29T

Central drain pan kit KWC26B160 KWC26B280

RXYQ-M9 5 8, 10 12, 14, 16


Cool/heat selector KRC19-26A
Fixing box KJB111A
Refnet header KHRQ22M29H KHRQ22M29H KHRQ22M29H
KHRQ22M64H
Refnet joint KHRQ22M20T
KHRQ22M20T
KHRQ22M20T KHRQ22M29T
KHRQ22M29T
KHRQ22M64T
Central drain pan kit KWC26B160 KWC26B280 KWC26B450

RXYQ-M9 18, 20 22, 24, 26 28 30, 32


Cool/heat selector KRC19-26A
Fixing box KJB111A
Refnet header KHRQ22M29H
KHRQ22M64H
KHRQ22M75H
Refnet joint KHRQ22M20T, KHRQ22M29T, KHRQ22M64T, KHRQ22M75T
Outdoor unit multi connection piping kit BHFQ22M909
Central drain pan kit KWC26B280
KWC26B280 x 2 KWC26B450 x 2 KWC26B450 x 2
KWC26B450

RXYQ-M9 34, 36 38 40, 42 44, 46, 48


Cool/heat selector KRC19-26A
Fixing box KJB111A
Refnet header KHRQ22M29H
KHRQ22M64H
KHRQ22M75H
Refnet joint KHRQ22M20T7, KHRQ22M29T7, KHRQ22M64T7, KHRQ22M75T7
Outdoor unit multi connection piping kit BHFQ22M1359
Central drain pan kit KWC26B280 x 2 KWC26B280 KWC26B280
KWC26B450 x 3
KWC26B450 KWC26B450 x 2 KWC26B450 x 2

page
44
REYQ-M7 8, 10 12, 14, 16
Refnet header KHRQ23M29H KHRQ23M29H
KHRQ23M64H
Refnet joint KHRQ23M20T, KHRQ23M29T KHRQ23M20T, KHRQ23M29T, KHRQ23M64T
Central drain pan kit KWC26B280 KWC26B450

REYQ-M7 18, 20 22, 24, 26 28 30, 32


Refnet header KHRQ23M29H, KHRQ23M64H, KHRQ23M75H7
Refnet joint KHRQ23M20T, KHRQ23M29T, KHRQ23M64T, KHRQ23M75T
Outdoor unit multi connection piping kit BHFQ23M907
Central drain pan kit KWC26B280
KWC26B280 x 2 KWC26B450 x 2 KWC26B450 x 2
KWC26B450

REYQ-M7 34, 36 38 40, 42 44, 46, 48


Refnet header KHRQ23M29H7 (max. 8 branches), KHRQ25M72H (max. 8 branches), KHRQ23M75H7 (max. 8 branches)
Refnet joint KHRQ23M20T, KHRQ23M29T, KHRQ23M64T, KHRQ23M75T
Outdoor unit multi connection piping kit BHFQ23M1357
Central drain pan kit KWC26B280 x 2 KWC26B280 KWC26B280
KWC26B450 x 3
KWC26B450 KWC26B450 x 2 KWC26B450 x 2

BSVQ-M 100 160 250


Cool/heat selector KRC19-26A
Fixing box KJB111A

RWEYQ-M 10 20 30
Cool/heat selector KRC19-26A
Fixing box KJB111A
REFNET header Heat recovery KHRQ23M29H KHRQ23M29H, KHRQ23M64H, KHRQ23M75H
Heat pump KHRQ22M29H KHRQ22M29H, KHRQ22M64H, KHRQ22M75H
REFNET joint Heat recovery KHRQ23M20T, KHRQ23M29T KHRQ23M20T, KHRQ23M29T, KHRQ23M64T, KHRQ23M75T
Heat pump KHRQ22M20T, KHRQ22M29T KHRQ22M20T, KHRQ22M29T, KHRQ22M64T, KHRQ22M75T
Outdoor unit multi connection piping kit Heat recovery - BHFP26MA56 BHFP26MA84
Heat pump - BHFP22MA56 BHFP22MA84
Water piping strainer BWU26A15 (1.47MPa) ; BWU26A20 (1.96MPa)

page
45
P
Product Features
I N D O O R U N I T S
S
Survey
Indoor Units
4-way blow ceiling mounted cassette (600mm x 600mm)
20-25-32-40-50
FXZQ p. 48
4-way blow ceiling mounted cassette
20-25-32-40-50-63-80-100-125
FXFQ p. 50
2-way blow ceiling mounted cassette
20-25-32-40-50-63-80-125
FXCQ p. 52
Ceiling mounted corner cassette
25-32-40-63
FXKQ p. 54
Concealed ceiling unit (small)
20-25
FXDQ p. 56
Slim concealed ceiling unit
20-25-32-40-50-63
FXDQ-N p. 58
Concealed ceiling unit
20-25-32-40-50-63-80-100-125
FXSQ p. 60
Concealed ceiling unit (large)
40-50-63-80-100-125-200-250
FXMQ p. 62
Wall mounted unit
20-25-32-40-50-63
FXAQ p. 64
4-way blow ceiling suspended unit
71-100-125
FXUQ p. 66
Ceiling suspended unit
32-63-100
FXHQ p. 68
Floor standing unit
20-25-32-40-50-63
FXLQ p. 70
Concealed floor standing unit
20-25-32-40-50-63
FXNQ p. 70

page
47
4-WAY BLOW

CEILING
F
Z X
Stylish & compact
Z Q
• New and extremely compact casing (575mm in depth) enables unit
to fit flush into ceilings and match standard architectural modules,
without cutting ceiling tiles
• Modern style decoration panel in super white (RAL9010)
• Whisper quiet operation with sound pressure levels as low as
MOUNTED 25dBA
Excellent low draught characteristics
• Auto swing:
Vertical auto swing moves the discharge flaps up and down to
CASSETTE distribute air effectively throughout the room. Since the flaps can
move to a 0 degree position, virtually no draught can be
experienced
(600mm x 600mm) Ceiling void
is 295 mm

60°
2-way 4-way
• 5 different air flow patterns:
2
3
4 2
3
4 Any one of 5 air flow patterns can be freely selected between
1 1

zero and 60 degrees and will then be maintained during the


operational cycle of the air conditioner.
3 3 3 3
• Air can be discharged in any of 4 directions. Possibility to shut one
2
1
4 2
1
4 2
1
4 2
1
4
or 2 flaps for easy installation in corners
3-way
• Since the switch box is located within the unit, it is easy to access
from below for maintenance without removing ceiling tiles
• The unit is provided with a standard 500mm lift drain pump

500mm

Super silent, stylish unit


BRC1D527 BRC7E531W/530W

page
48
FXZQ
FXZQ - M7V1B 20 25 32 40 50
Cooling capacity kW 2.2 2.8 3.6 4.5 5.6
Heating capacity kW 2.5 3.2 4,0 5,0 6.3
Power input Cooling W 73 73 76 89 115
Heating W 64 64 68 80 107
Power supply VE 1~, 50Hz, 220-240V
Dimensions Unit HxWxD mm 286 x 575 x 575
Decoration panel HxWxD mm 55 x 700 x 700
Weight Unit kg 18
Decoration panel kg 2.7
Casing galvanised steel plate
Colour Decoration panel white (RAL 9010)
Sound pressure level High dB(A) 30 30 32 36 41
Low dB(A) 25 25 26 28 33
Sound power level dB(A) 47 47 49 53 58
Aif flow rate High m3/h 540 540 570 660 840
Low m3/h 420 420 420 480 600
Air filter resin net with mold resistant
Temperature control microprocessor thermostat for cooling and heating
Piping connections Liquid flare mm 6.4
Gas flare mm 12.7
Drain mm VP20, external diameter 26, internal diameter 20
Sound absorbind thermal insulation foamed polystyrene / foamed polyethylene
Safety devices PC board fuse, fan motor thermal protector

Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB
outdoor temperature: 35°CDB
equivalent piping length: 7.5m (horizontal)
• Nominal heating capacities are based on: indoor temperature: 20°CDB
outdoor temperature: 7°CDB, 6°CWB
equivalent piping length: 7.5m (horizontal)
• Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat

ACCESSORIES
FXZQ - M7V1B 20 25 32 40 50
Wired remote control BRC1D527
Infrared remote control Cooling only BRC7E531W
Heat pump BRC7E530W
Decoration panel BYFQ60B7W1
Sealing member of air discharge outlet KDBHQ44B60
Panel spacer KDBQ44B60
Replacement long life filter KAFQ441B60
Fresh air intake kit Direct installation type KDDQ44X60

page
49
4-WAY BLOW

CEILING
F
F X
Elegant & compact
F Q
• Sound pressure levels down to 28dBA leave even the most sensitive
occupant undisturbed
• Slimmer unit requires only 240mm of ceiling space
(298mm for model 80 and above)
• Air flow distribution to suit ceiling heights up to 4.2m for model
80 and above
MOUNTED • Drain-up pump with increased lift of 750mm fitted as standard

CASSETTE 750 mm

• Air can be discharged in any of four directions. Possibility to shut one


or two flaps for easy installation in corners or to use 1 or 2 branches

4-way 3-way discharge 2-way discharge Single branch - 8 patterns 2 branches - 3 patterns
discharge
Branched

Branched Closed
Closed Piping
The unit can be location
installed in corners Piping
location
❚ ... indicates the piping connection direction

• Choice of 3 auto-swing positions for maximum comfort:


standard, draught prevention, ceiling soiling prevention

Simple installation
• Easy to fit decoration panel
• Suction grille can be rotated by 90°
• Easy height adjustment via adjuster slot

Easy maintenance
• Easy to clean suction grille and filter
• Extended cleaning cycle of the heat exchanger: once every 3 years

Fits flush into each ceiling


BRC1D527 BRC7C512W/513W

page
50
FXFQ
FXFQ - M7V1B 20 25 32 40 50 63 80 100 125
Nominal cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0
Nominal heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0
Power input Cooling W 90 97 106 118 173 184 230
Heating W 75 82 90 101 159 169 215
Power supply 1~, 50Hz, 230V
Dimensions Unit HxWxD mm 230x840x840 288x840x840
Decoration panel HxWxD mm 40x950x950 40x950x950
Weight Unit kg 24 28
Decoration panel kg 5 5
Casing galvanised steel plate
Colour Decoration panel white (10Y9/0.5)
Sound pressure level High dB(A) 31 31 31 32 33 34 38 40 45
Low dB(A) 28 28 28 28 28 29 32 33 36
Sound power level dB(A) 48 48 48 49 50 51 54 56 61
Air flow rate High m3/h 780 780 780 840 960 1,080 1,680 1,680 1,860
Low m3/h 600 600 600 600 660 840 1,200 1,260 1,440
Air filter resin net with mold resistant
Temperature control microprocessor thermostat for cooling and heating
Piping connections Liquid Flare mm Ø 6.4 Ø 9.5
Gas Flare mm Ø 12.7 Ø 15.9
Drain mm VP25, external diameter 32, internal diameter 25
Sound absorbing thermal insulation foamed polystyrene
Safety devices PC board fuse, fan motor thermal protector, drain pump fuse
Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB • equivalent refrigerant piping: 8m, level difference : 0m
• Nominal heating capacities are based on: indoor temperature: 20°CDB • outdoor temperature: 7°CDB, 6°CWB • equivalent refrigerant piping: 8m, level difference : 0m
• Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat
• The sound pressure is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment
• The sound power level is an absolute value indicating of the “power” which a sound source generates

ACCESSORIES
FXFQ - M7V1B 20 25 32 40 50 63 80 100 125
Wired remote control BRC1D527
Infrared remote control Cooling only BRC7C513W
Heat pump BRC7C512W
Decoration panel BYC125K7W1B
High efficiency filter 65% *1 Colorimetric method KAFJ556K80 KAFJ556K160
High efficiency filter 90% *1 Colorimetric method KAFJ557K80 KAFJ557K160
Replacement high eff. filter 65% Colorimetric method KAFJ552K80 KAFJ552K160
Replacement high eff. filter 90% Colorimetric method KAFJ553K80 KAFJ553K160
Filter chamber for above KDDFJ55K160
Replacement long life filter Non woven type KAFJ55K160
Replacement ultra long life filter KAFJ551K160H
Fresh air intake kit Chamber type without T-shape and fan KDDJ55B160
with T-shape and fan KDDJ55B160F
with T-shape, without fan KDDJ55B160K
Direct installation type KDDJ55X160
Air discharge outlet sealing member KDBHJ55K160
Panel spacer KDBP55H160W
Branch duct chamber KDJ55B80 KDJ55B160
Chamber connection kit KKSJ55K160

page
51
2-WAY

BLOW
F
C X
Stylish & compact
C Q
• Slim unit can be installed in a ceiling void of only 355mm

minimum ceiling
height is 35 cm

CEILING • Depth of all units is 600mm : easy installation in false ceilings

• Whisper quiet operation: down to 28dBA


MOUNTED
• Long life filter is provided as standard

CASSETTE • Drain-up pump with 600mm lift fitted as standard

600mm

• Leaves maximum floor and wall space for furniture and


decorations
• Auto-swing mechanism ensures even room air and temperature
distribution and prevents ceiling soiling.

Less maintenance

• Maintenance operations can be performed by removing the front panel


• Easy to clean flat suction grille
• Detachable swing flaps

E a s y i n s t a l l a t i o n i n n a r ro w c e i l i n g v o i d s
BRC1D527 BRC7C62/67

page
52
FXCQ
FXCQ - M7V1B 20 25 32 40 50 63 80 125
Nominal cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0
Nominal heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 10.0 16.0
Power input Cooling W 77 92 130 161 209 256
Heating W 44 59 97 126 176 223
Power supply 1~, 50Hz, 230V
Dimensions Unit HxWxD mm 305x780x600 305x995x600 305x1,180x600 305x1,670x600
Decoration panel HxWxD mm 53x1,030x680 53x1,245x680 53x1,430x680 53x1,920x680
Weight Unit kg 26 31 32 35 47 48
Decoration panel kg 8 8.5 9.5 12
Casing galvanised steel plate
Colour Decoration panel white (10Y9/0.5)
Sound pressure level High dB(A) 33 35 35.5 38 40 45
Low dB(A) 28 29 30.5 33 35 39
Sound power level dB(A) 45 50 50 52 54 60
Air flow rate High m3/h 420 540 720 990 1,560 1,980
Low m3/h 300 390 540 780 1,260 1,500
Air filter resin net with mold resistant
Temperature control microprocessor thermostat for cooling and heating
Piping connections Liquid Flare mm Ø 6.4 Ø 9.5
Gas Flare mm Ø 12.7 Ø 15.9
Drain mm VP25, external diameter 32, internal diameter 25
Sound absorbing thermal insulation felt / urethane foam
Safety devices PC board fuse, fan motor thermal protector, drain pump fuse

Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB • equivalent refrigerant piping: 8m • level difference: 0m
• Nominal heating capacities are based on: indoor temperature: 20°CDB • outdoor temperature: 7°CDB, 6°CWB • equivalent refrigerant piping: 8m • level difference: 0m
• Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat

ACCESSORIES
FXCQ - M7V1B 20 25 32 40 50 63 80 125
Wired remote control BRC1D527
Infrared remote control Cooling only BRC7C67
Heat pump BRC7C62
Decoration panel BYBC32GJW1 BYBC50GJW1 BYBC63GJW1 BYBC125GJW1
High efficiency filter 65% *1 KAFJ532G36 KAFJ532G56 KAFJ532G80 KAFJ532G160
High efficiency filter 90% *1 KAFJ533G36 KAFJ533G56 KAFJ533G80 KAFJ533G160
Filter chamber for bottom suction KDDFJ53G36 KDDFJ53G56 KDDFJ53G80 KDDFJ53G160
Replacement long life filter KAFJ531G36 KAFJ531G56 KAFJ531G80 KAFJ531G160
Note:
*1. Filter chamber is required when installing a high efficiency filter

page
53
CEILING

MOUNTED
F
K X K
• Choice of 3 auto-swing positions:
Q
1
Standard
2
Draught
prevention
3
Ceiling soiling
prevention

Note:
Standard setting when shipped.

CORNER
• Auto-swing mechanism ensures even room air and temperature
distribution
CASSETTE
• Optimum air flow conditions are created by either downward air
discharge or frontal air discharge (via optional grille) or a
combination of both

Downward discharge Frontal discharge Combination

Closed by the decoration panel

• Leaves maximum floor and wall space for furniture, decoration


and fittings

• The corner cassette is specifically


designed for use in rooms with
Min. 195 mm
shallow ceiling voids (only
220mm ceiling space required, 20 mm
Panel spacer

195mm with panel spacer,


available as accessory)

• Drain-up pump with 500mm lift


500 mm
fitted as standard

S l i m d e s i g n fo r f l e x i b l e i n s t a l l a t i o n
BRC1D527 BRC4C63/61

page
54
FXKQ
FXKQ - MVE 25 32 40 63
Cooling capacity kW 2.8 3.6 4.5 7.1
Heating capacity kW 3.2 4.0 5.0 8.0
Power input Cooling W 66 76 105
Heating W 46 56 85
Power supply VE 1~, 50Hz, 220-240V
Dimensions Unit HxWxD mm 215x1,110x710 215x1,310x710
Decoration panel HxWxD mm 70x1,240x800 70x1,440x800
Weight Unit kg 31 34
Decoration panel kg 8.5 9.5
Material Unit galvanised steel plate
Colour Decoration panel white
Sound pressure level - 220V High dB(A) 38 40 42
Low dB(A) 33 34 37
Sound power level dB(A) * * *
Air flow rate High m3/h 660 780 1,080
Low m3/h 540 600 900
Air filter resin net with mold resistant
Temperature control microprocessor thermostat for cooling and heating
Piping connections Liquid Flare mm Ø 6.4 Ø 9.5
Gas Flare mm Ø 12.7 Ø 15.9
Drain mm VP25 (external diameter 32, internal diameter 25)
Sound absorbing thermal insulation foamed polyethylene
Safety devices PC board fuse, fan motor thermal fuse, drain pump thermal fuse PC board fuse, fan motor thermal protector, drain pump thermal fuse
Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB • equivalent refrigerant piping: 7.5m (horizontal)
• Nominal heating capacities are based on: indoor temperature: 20°CDB • outdoor temperature: 7°CDB, 6°CWB • equivalent refrigerant piping: 7.5m (horizontal)
• Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat
• *Data were not available at the time of publication

ACCESSORIES
FXKQ - MVE 25 32 40 63
Wired remote control BRC1D527
Infrared remote control Cooling only BRC4C63
Heat pump BRC4C61
Decoration panel BYK45FJW1 BYK71FJW1
Panel spacer KPBJ52F56W KPBJ52F80W
Replacement long life filter KAFJ521F56 KAFJ521F80
Air discharge grille K-HV7AW K-HV9AW
Air discharge blind panel KDBJ52F56W KDBJ52F80W
Flexible duct (with shutter) KFDJ52F56 KFDJ52F80

page
55
CONCEALED

CEILING
D
F X D Q
• Designed for hotel use: very compact dimensions (230mm high x
652mm wide)

• Can easily be mounted in a ceiling void

• Since only the suction and discharge grilles are visible, the system
will blend in any interior décor
UNIT
• The air suction direction can be altered from rear to bottom suction

(SMALL) • Standard suction air filter

• Extremely quiet in operation, both indoors and outdoors

• For easy mounting, the drain pan connection can be located to the
left or right of the unit

BRC1D527 BRC4C62/64

B l e n d s b e a u t i f u l l y w i t h h o t e l ro o m s
BRC2A51 BRC3A61

page
56
FXDQ
FXDQ - M7V1B 20 25
Nominal cooling capacity kW 2.2 2.8
Nominal heating capacity kW 2.5 3.2
Power input Cooling W 50
Heating W 50
Power supply 1~, 50Hz, 230V
Dimensions HxWxD mm 230x502x652
Weight kg 17
Casing galvanised steel plate
Sound pressure level High dB(A) 37
Low dB(A) 32
Sound power level dB(A) 50
Air flow rate High m3/h 402 444
Low m3/h 312 348
Air filter resin net with mold resistant
Temperature control microprocessor thermostat for cooling and heating
Piping connections Liquid Flare mm Ø6.4
Gas Flare mm Ø12.7
Drain mm VP25, external diameter 27.2, internal diameter 21.6
Safety devices PC board fuse

Notes : • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB
outdoor temperature: 35°CDB
equivalent refrigerant piping: 8m
level difference : 0m
• Nominal heating capacities are based on: indoor air temperature: 20°CDB
outdoor temperature: 7°CDB, 6°CWB
equivalent refrigerant piping: 8m
level difference : 0m
• Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.

ACCESSORIES
FXDQ - M7V1B 20 25
Wired remote control BRC1D527, BRC2A51, BRC3A61
Infrared remote control Cooling only BRC4C64
Heat pump BRC4C62
Wiring adapter (hour meter) *1 EKRP1B2
Note:
*1. Fixing box: KRP1A90

page
57
SLIM

CONCEALED
D
FXDQ-N
• Slim design for flexible installation

200mm

• Compact dimensions, can easily be


mounted in a ceiling void of only 240mm
CEILING UNIT Air filter
Suction Chamber
[Duct connection]

• Quiet operation: down to 29 dBA sound pressure level

• Blends unobtrusively with any interior décor

• Can be installed in both new and existing buildings

• Leaves maximum floor and wall space for furniture, decorations


and fittings

• Medium external static pressure facilitates unit use with flexible


ducts of varying lengths

• Drain-up pump with 750mm lift fitted as


standard
BRC1D527 BRC4C62/64

Ceiling

E a s y i n s t a l l a t i o n i n n a r ro w c e i l i n g v o i d s
BRC2A51 BRC3A61

page
58
FXDQ-N
FXDQ-NVE 20 25 32 40 50 63
Cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1
Heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0
Power input Cooling W 150 150 150 160 165 181
Heating W 137 137 137 147 152 168
Power supply VE 1~, 50Hz, 220-240V
Dimensions HxWxD mm 200x900x620 200x1,100x620
Weight kg 26 26 26 27 28 31
Casing galvanised steel plate
Sound pressure level High dB(A) 33 33 33 34 35 36
Low dB(A) 29 29 29 30 31 32
Sound power level dB(A) * * * * * *
Air flow rate High m3/min 9.5 9.5 10.5 10.5 12.5 16.5
Low m3/min 7.5 7.5 8.5 8.5 10.0 13.0
Air filter removable, washable, mildew proof
Temperature control microprocessor thermostat for cooling and heating
Piping connections Liquid mm 6.4 6.4 6.4 6.4 6.4 9.5
Gas mm 12.7 12.7 12.7 12.7 12.7 15.9
Drain mm VP (external diameter 26, internal diameter 20)
Sound absorbing thermal insulation foamed polyethylene
Safety devices PC board fuse, fan motor thermal protector

Notes: • Nominal cooling capacities are based on: • Indoor temperature: 27°CDB, 19°CWB
• Outdoor temperature: 35°CDB
• Equivalent piping length: 7.5m (horizontal)
• Nominal heating capacities are based on: • Indoor temperature: 20°CDB
• Outdoor temperature: 7°CDB, 6°CWB
• Equivalent piping length: 7.5m (horizontal)
• Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat
• * Data were not available at time of publication
• The sound pressure values are mentioned for a unit installed with rear suction

ACCESSORIES
FXDQ-NVE 20 25 32 40 50 63
Infrared remote control cooling BRC4C64
heating BRC4C62
Wired remote control BRC1D527, BRC2A51, BRC3A61

page
59
CONCEALED

CEILING
F
S X S Q
• High external static pressure facilitates unit use with flexible ducts
of varying lengths

• Low sound pressure level - 28dBA. The quiet operation of this


model is ideal for exclusive stores and offices

• Blends unobtrusively with any interior décor


UNIT
• When using suction panel,
unit requires only 350mm Min.
of ceiling space 350mm

• Drain-up pump with lift up to 625mm


625mm fitted as standard

• The air suction direction can be altered from rear to bottom


suction

• The switch box can be reached from the side or from the bottom
side of the unit for easy servicing

• Long life filter fitted as standard

BRC1D527 BRC4C62/64

H i g h f l e x i b i l i t y fo r a w i d e v a r i e t y o f a p p l i c a t i o n s
BRC2A51 BRC3A61

page
60
FXSQ
FXSQ - M7V1B 20 25 32 40 50 63 80 100 125
Nominal cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0
Nominal heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0
Power input Cooling W 110 114 127 143 189 234 242 321
Heating W 90 94 107 123 169 214 222 301
Power supply 1~, 50Hz, 230V
Dimensions Unit HxWxD mm 300x550x800 300x700x800 300x1,000x800 300x1,400x800
Decoration panel HxWxD mm 55x650x500 55x800x500 55x1,100x500 55x1,500x500
Weight Unit kg 30 30 31 41 51 52
Decoration panel kg 3 3.5 3.5 4.5 6.5 6.5
Casing galvanised steel plate
Colour Decoration panel white 10Y9/0.5
Sound pressure level High dB(A) 32 33 33 35 35 37 38 40
Low dB(A) 28 28 29 31 30 31 33 35
Sound power level dB(A) 50 51 56 58 56 55 56 65
Air flow rate High m3/h 540 570 690 900 1,260 1,620 1,680 2,280
Low m3/h 390 420 540 660 930 1,200 1,230 1,680
Air filter resin net with mold resistant
Temperature control microprocessor thermostat for cooling and heating
Piping connections Liquid Flare mm Ø 6.4 Ø 9.5
Gas Flare mm Ø 12.7 Ø 15.9
Drain mm VP25, external diameter 32, internal diameter 25
Sound absorbing thermal insulation foamed polyurethane
Safety devices PC board fuse, fan motor thermal protector, drain pump fuse

Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB • equivalent refrigerant piping: 8m • level difference: Om
• Nominal heating capacities are based on: indoor temperature: 20°CDB • outdoor temperature: 7°CDB, 6°CWB • equivalent refrigerant piping: 8m • level difference: Om
• Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat
• The sound pressure values are mentioned for a unit installed with rear suction

ACCESSORIES
FXSQ - M7V1B 20 25 32 40 50 63 80 100 125
Wired remote control BRC1D527, BRC2A51, BRC3A61
Infrared remote control Cooling only BRC4C64
Heat pump BRC4C62
Decoration panel BYBS32DJW1 BYBS45DJW1 BYBS71DJW1 BYBS125DJW1
Service access panel KTBJ25K36W KTBJ25K56W KTBJ25K80W KTBJ25K160W
High efficiency filter 65% *2 KAFJ252L36 KAFJ252L56 KAFJ252L80 KAFJ252L160
High efficiency filter 90% *2 KAFJ253L36 KAFJ253L56 KAFJ253L80 KAFJ253L160
Filter chamber for bottom suction KAJ25L36D KAJ25L56D KAJ25L80D KAJ25L160D
Filter chamber rear suction KAJ25L36B KAJ25L56B KAJ25L80B KAJ25L160B
Air suction canvas KSA-25K36 KSA-25K56 KSA-25K80 KSA-25K160
Screening door/blind board KBBJ25K36 KBBJ25K56 KBBJ25K80 KBBJ25K160
Air discharge adapter for round duct KDAJ25K36 KDAJ25K56 KDAJ25K71 KDAJ25K140

Notes: • *1. A wiring adapter (KRP1B61) per indoor unit is required if installing an electric heater.
• *2. If installing a high efficiency filter in the ceiling mounted built-in unit, an assembly chamber for either bottom or rear suction is required.
• *3. An electric heater cannot be used for VRV system cooling only.

page
61
CONCEALED

CEILING
M
F X M Q
• Leaves maximum floor and wall space for furniture decoration and
fittings

• Complete range of models (5 ➞ 31.5 kW)

• More than 150 Pa external static pressure allows extensive


ductwork runs and flexible application: ideal for use in large areas
UNIT
• External static pressure can be easily adjusted using a change-over
switch inside the electrical box to meet the resistance in the duct
(LARGE) system

• Drain-up height: 294 mm for class 40 to 125


375 mm for class 200, 250

• Built-in drain pump (accessory):


housing the drain pump inside the unit has reduced the required
installation space
BUILT-IN DRAIN PUMP

Min.
Min. 470 mm
590 mm

Indoor unit 120

Drain pump kit Indoor unit

BRC1D527 BRC4C62/64

H i g h s t a t i c p re s s u re a l l o w s f l e x i b l e d u c t d e s i g n
BRC2A51 BRC3A61

page
62
FXMQ
FXMQ - MVE 40 50 63 80 100 125 200 250
Nominal cooling capacity kW 4.5 5.6 7.1 9.0 11.2 14.0 22.4 28.0
Nominal heating capacity kW 5.0 6.3 8.0 10.0 12.5 16.0 25.0 31.5
Power input Cooling W 211 284 411 619 1,294 1,465
Heating W 211 284 411 619 1,294 1,465
Power supply 1~, 50Hz, 220-240V
Dimensions HxWxD mm 390x720x690 390x1,110x690 470x1,380x1,100
Weight kg 44 45 63 65 137
Casing galvanised steel plate
Sound pressure level - 220V High dB(A) 39 42 43 45 48
Low dB(A) 35 38 39 42 45
Sound power level dB(A) * * * * *
Air flow rate High m3/h 840 1,170 1,740 2,160 3,480 4,320
Low m3/h 690 960 1,380 1,740 3,000 3,720
Air filter cf. note 4
Temperature control microprocessor thermostat for cooling and heating
Piping connections Liquid Flare mm Ø 6.4 Ø 9.5 Ø 9.5
Gas mm Ø 12.7(flare) Ø 15.9(flare) Ø19.1(brazing) Ø22.2(brazing)
Drain mm VP25, external diameter 32, internal diameter 25 PS1B
Sound absorbing thermal insulation glass fiber
Safety devices PC board fuse, fan motor thermal protector

Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB
outdoor temperature: 35°CDB
equivalent refrigerant piping: 7.5m (horizontal)
• Nominal heating capacities are based on: indoor temperature: 20°CDB
outdoor temperature: 7°CDB, 6°CWB
equivalent refrigerant piping: 7.5m (horizontal)
• Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat
• The air filter is not a standard accessory, but please mount it in the duct system at the suction side.
Select its colorimetric method (gravity method) 50% or more.
• *Data were not available at the time of publication

ACCESSORIES
FXMQ - MVE 40 50 63 80 100 125 200 250
Wired remote control BRC1D527, BRC2A51, BRC3A61
Infrared remote control Cooling only BRC4C64
Heat pump BRC4C62
Drain pump kit KDU30L125VE KDU30L250VE
High efficiency filter 65% KAFJ302L71 KAFJ302L140 KAFJ372L280
High efficiency filter 90% KAFJ303L71 KAFJ303L140 KAFJ373L280
Filter chamber KDDJ30L71 KDDJ30L140 KDJ3705L280
Replacement long life filter KAFJ301L71 KAFJ301L140 KAFJ371L280

page
63
WALL

MOUNTED
A
F X A Q
• Compact and stylish design blends unobtrusively in any interior décor
• Dramatic weight reduction of 48% compared to the previous series
• Auto-swing mechanism ensures efficient air distribution via louvers
that close automatically when the unit is switched off
• Comfortable air flow: the wide air discharge outlet distributes a
UNIT comfortable air flow throughout the entire room
• Both horizontal flaps and front panel can easily be removed and
washed
• 5 different discharge angles can be
programmed via the remote control 10°
25°
40°
55° 70°

• Discharge angle automatically returns


to its previous position on restart
(initial setting 10 degrees for cooling 10° Cooling

and 70 degrees for heating) 70° Heating

• All maintenance operations can be carried out from the front of the
unit
• Drain pipe can be installed either to the left or right side of the unit

• Drain-pump kit is available as Height of drain-up

optional accessory, which lifts the


drain 1,000mm from the bottom 1,000mm
of the unit
Drain-up kit
Indoor unit
Drain-up kit

Q u i e t o p e ra t i o n w i t h a u t o - s w i n g c o m fo r t
BRC1D527 BRC7E618/619

page
64
FXAQ
FXAQ-MVE 20 25 32 40 50 63
Nominal cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1
Nominal heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0
Power input Cooling W 16 22 27 20 27 50
Heating W 24 27 32 20 32 60
Power supply 1~, 50Hz, 220-240V
Dimensions HxWxD mm 290x795x230 290x1,050x230
Weight kg 11 14
Colour white (3.OY8.5/0.5)
Sound pressure level High dB(A) 35 36 37 39 42 46
Low dB(A) 29 29 29 34 36 39
Sound power level dB(A) * * * * * *
Air flow rate High m3/h 450 480 540 720 900 1,140
Low m3/h 270 300 330 540 720 840
Air filter resin net washable
Temperature control microprocessor thermostat for cooling and heating
Piping connections Liquid Flare mm Ø6.4 Ø9.5
Gas Flare mm Ø12.7 Ø15.9
Drain mm VP13 (external diameter 18, internal diameter 14)
Sound absorbing thermal insulation foamed polystyrene / foamed polyethylene
Safety devices PC board fuse
Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB
outdoor temperature: 35°CDB
equivalent refrigerant piping: 5m (horizontal)
• Nominal heating capacities are based on: indoor temperature: 20°CDB
outdoor temperature: 7°CDB, 6°CWB
equivalent refrigerant piping: 5m (horizontal)
• Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat
• *Data were not available at the time of publication

ACCESSORIES
FXAQ-MVE 20 25 32 40 50 63
Wired remote control BRC1D527
Infrared remote control Cooling only BRC7E619
Heat pump BRC7E618
Drain pump kit K-KDU572CVE

page
65
4-WAY

BLOW
U
F X U Q
• Group control with other VRV indoor units

• Cool/heat selection available

• To prevent cold draught at hot start, defrost and oil return in heating

• 5m maximum distance between indoor unit and junction box


CEILING
• Air can be discharged in any of four directions

SUSPENDED • Possibility to shut one or two flaps


for easy installation in corners

UNIT

• Auto-swing mechanism ensures even room air and temperature


distribution

• Air flow distribution for ceiling heights up to 3.5m

• Air can be discharged at 5 different


angles between 0 and 60 degrees.

BRC1D527 BRC7C529W/528W

• Extremely quiet in operation both indoors and outdoors

• The air filter, drain pan and heat exchanger fin are mildew proof
and anti-bacterial treated

• Drain-up pump with increased lift of 500mm

I d e a l fo r i n s t a l l a t i o n i n n e w o r e x i s t i n g b u i l d i n g s
BEVQ-MVE

page
66
FXUQ
FXUQ-MV1 71 100 125
Nominal cooling capacity kW 8.0 11.2 14.0
Nominal heating capacity kW 9.0 12.5 14.0
Power input Cooling W 180 289 289
Heating W 160 269 269
Power supply V1 1~, 50Hz, 230V
Dimensions HxWxD mm 165x895x895 230x895x895 230x895x895
Weight kg 25 31 31
Colour white
Sound pressure level High dB(A) 40 43 44
Low dB(A) 35 38 39
Sound power level High dB(A) 56 59 60
Low dB(A) 51 54 55
Air flow rate High m3/h 1,140 1,740 1,920
Low m3/h 840 1,260 1,380
Air filter resin net with mold resistant
Piping connections Liquid Flare mm 9.5 9.5 9.5
Gas Flare mm 15.9 15.9 15.9
Drain Flare mm external diameter 26, internal diameter 20
Heat insulation heat resistant foamed polyethylene, regular foamed polyethylene
Safety devices fan motor thermal protector
Combination with junction box BEVQ71MVE BEVQ100MVE BEVQ125MVE

Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB • outdoor temperature: 35°CDB, 24° CWB
• Nominal heating capacities are based on: indoor temperature: 20°CDB, 15° CWB • outdoor temperature: 7°CDB, 6°CWB
• Capacities are net including a deduction for cooling (an addition for heating) for indoor fan motor heat

ACCESSORIES
FXUQ-MV1 71 100 125
Wired remote control BRC1D527
Infrared remote control Cooling only BRC7C529W
Heat pump BRC7C528W
Sealing member of air discharge outlet KDBHJ49F80 KDBHJ49F140
Air discharge decoration panel KDBTJ49F80 KDBTJ49F140
Vertical flap kit KDGJ49F80 KDGJ49F140
Replacement long life filter KAFJ495F140
L-type connection piping kit KHFP49M63 KHFP49M140

JUNCTION BOX FOR


CONNECTION TO VRV
BEVQ-MVE 71 100 125
Dimensions HxWxD mm 100x350x225
Weight kg 3.0 3.0 3.5
Casing galvanised steel plate
Power supply VE 1~, 50Hz, 220-240V

page
67
CEILING

SUSPENDED
H
F X H Q
• Quiet in operation: down to 31 dBA sound pressure level

• Leaves maximum floor and wall space for furniture and decoration

• Can be installed in both new and existing buildings

• Use of W-Coanda flap enhances Sound absorption member

UNIT horizontal and vertical air


circulation characteristics

Turbulent flow Silent stream fan


Straightening vane

• Wider air discharge thanks to


Coanda effect: up to 100 degrees

Coanda effect 100°

• Long life filter fitted as standard

• Drain-up kit with 600mm lift


available as accessory

Drain-up kit
(built inside main unit)

• Easy installation and maintenance

Super silent, slim unit with wider air flow


BRC1D527 BRC7E63W/66

page
68
FXHQ
FXHQ - MVE 32 63 100
Nominal cooling capacity kW 3.6 7.1 11.2
Nominal heating capacity kW 4.0 8.0 12.5
Power input Cooling W 111 115 135
Heating W 111 115 135
Power supply 1~, 50Hz, 220-240V
Dimensions HxWxD mm 195x960x680 195x1,160x680 195x1,400x680
Weight kg 24 28 33
Colour white (10Y9/0.5)
Sound pressure level High dB(A) 36 39 45
Low dB(A) 31 34 37
Sound power level dB(A) * * *
Air flow rate High m3/h 720 1,050 1,500
Low m3/h 600 840 1,170
Air filter resin net with mold resistant
Temperature control microprocessor thermostat for cooling and heating
Piping connections Liquid Flare mm Ø 6.4 Ø 9.5 Ø 9.5
Gas Flare mm Ø 12.7 Ø 15.9 Ø 15.9
Drain mm VP20 (external diameter 26, internal diameter 20)
Sound absorbing thermal insulation glass wool
Safety devices PC board fuse, fan motor thermal protector

Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB
outdoor temperature: 35°CDB
equivalent refrigerant piping: 7.5m (horizontal)
• Nominal heating capacities are based on: indoor temperature: 20°CDB
outdoor temperature: 7°CDB, 6°CWB
equivalent refrigerant piping: 7.5m (horizontal)
• Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat
• *Data were not available at the time of publication

ACCESSORIES
FXHQ - MVE 32 63 100
Wired remote control BRC1D527
Infrared remote control Cooling only BRC7E66
Heat pump BRC7E63W
Drain pump kit KDU50M60VE KDU50M125VE KDU50M125VE
Replacement long life filter Resin net KAFJ501D56 KAFJ501D80 KAFJ501D112
L-type piping kit For upward direction KHFP5M35 KHFP5M63 KHFP5M63

page
69
(CONCEALED)

FLOOR
L N
FXLQ/FXNQ
• Ideal for installation beneath a window

• The floor standing unit is a mere 222mm deep and 600mm high and
requires very little installation space

• Running the pipes from connections


at the back, enables the unit to be
STANDING wall mounted which in turn allows
cleaning beneath the unit where Wall mounted Floor standing

dust tends to accumulate


UNIT
• On site connection during installation is easier

• Long life filter fitted as standard

• All models are available with remote control

• The connecting port faces downward,


eliminating the need to attach
auxiliary piping
Connecting
port

Refrigerant
piping

BRC1D527 BRC4C64/62

T h e i d e a l u n i t fo r p e r i m e t e r a i r c o n d i t i o n i n g
BRC2A51 BRC3A61

page
70
FXLQ/FXNQ
FXLQ/FXNQ-MVE 20 25 32 40 50 63
Nominal cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1
Nominal heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0
Power input Cooling W 49 90 110
Heating W 49 90 110
Power supply 1~, 50Hz, 220-240V
Dimensions FXLQ HxWxD mm 600x1,000x222 600x1,140x222 600x1,420x222
FXNQ HxWxD mm 610x930x220 610x1,070x220 610x1,350x220
Weight FXLQ kg 25 30 36
FXNQ kg 19 23 27
Colour FXLQ ivory white (5Y7.5/1)
Casing FXNQ galvanised steel plate
Sound pressure level - 220V High dB(A) 35 35 38 39 40
Low dB(A) 32 32 33 34 35
Sound power level dB(A) * * * * *
Air flow rate High m3/h 420 480 660 840 960
Low m3/h 360 360 510 660 720
Air filter resin net with mold resistant
Temperature control microprocessor thermostat for cooling and heating
Piping connections Liquid Flare mm Ø6.4 Ø9.5
Gas Flare mm Ø12.7 Ø15.9
Drain mm Ø21 external diameter (vinyl chloride)
Sound absorbing thermal insulation glass fiber / urethane foam
Safety devices PC board fuse, fan motor thermal protector

Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB
outdoor temperature: 35°CDB
equivalent refrigerant piping: 7.5m (horizontal)
• Nominal heating capacities are based on: indoor temperature: 20°CDB
outdoor temperature: 7°CDB, 6°CWB
equivalent refrigerant piping: 7.5m (horizontal)
• Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat
• *Data were not available at the time of publication

ACCESSORIES
FXLQ/FXNQ-MVE 20 25 32 40 50 63
Wired remote control BRC1D527, BRC2A51, BRC3A61
Infrared remote control Cooling only BRC4C64
Heat pump BRC4C62
Replacement long life filter KAFJ361K28 KAFJ361K45 KAFJ361K71

page
71
P
Product Features
CONTROL SYSTEMS
Individual
Control
Systems
S
Survey
Control Systems
Simplified remote control

BRC2A51 p. 74
Simplified built-in remote control
for hotel applications

BRC3A61
Infrared remote control
p. 74

BRC4C*/BRC7C*
Wired remote control
p. 74

BRC1D527
Centralised remote control
p. 75

Centralised

DCS302C51
Control
Systems p. 76
Unified ON / OFF control

DCS301B51
Schedule timer
p. 76

DST301B51 p. 76

Daikin
Network
Solutions
DTA113B51 p. 77

DCS601C51 p. 78

DAM602A51/52/53 p. 80

DMS504B51 p. 81

page
73
DMS502A51 p. 81
I
Individual
Control Systems
BRC2A51
Simplified remote
control
• simple, compact and
easy to operate unit
• suitable for use in
Display :
• Cool/heat changeover
control
• Heat Recovery
Ventilation (HRV) in
• Malfunction
adjustment
• Operating mode
selection
• Fan speed control
hotel bedrooms. operation • Filter sign reset
• Set temperature • Inspection test /
• Operating mode operation
Operation buttons :
• Centralised control
• ON/OFF
indication
• Operating mode
• Fan speed
selection
• Defrost/hot start
• Fan speed control
• Temperature setting

BRC3A61
Simplified built-in
remote control for
Operation buttons :
• ON/OFF
Display :
• Heat Recovery
hotel applications • Fan speed control Ventilation (HRV) in
• compact,user friendly • Temperature setting operation
unit • Set temperature
• ideal for use in hotel • Operating mode
bedrooms. • Centralised control
indication
• Fan speed
• Defrost/hot start
• Malfunction

control
BRC4C*/BRC7C*
Infrared remote • Air flow direction
(FXHQ, FXFQ, FXCQ
Display:
• Operating mode
and FXAQ models • Battery change
only) • Set temperature
Operation buttons: • Operating mode • Air flow direction
• ON/OFF • Fan speed control (FXHQ, FXFQ,
• Timer mode start / • Filter sign reset FXCQ and FXAQ
stop • Inspection / test models only)
• Timer mode on/off indication • Programmed time
• Programme time
• Inspection/test
• Temperature setting
operation
• Fan speed

page
74
BRC1D527
Wired remote control
• Limit operation (min./max.): room temperature is controlled within adjustable
upper and lower limits. Limit operation can be activated manually or by
schedule timer
• Real time clock: indicates real time and day
• Schedule timer:
- It is possible to programme a weekly schedule timer
- It is possible to programme the remote control for each day of the week.
Five day actions can be set as follows:
BRC1D527 - set point: unit is switched ON and normal operation is maintained
- OFF: unit is switched OFF
- limits: unit is switched ON and min./max. control (cf.limit operation for
more details)
• Home leave (frost protection): during absence, the indoor temperature can
be maintained at a certain level. This function can also switch the unit
ON/OFF
• Different levels of disabled buttons can be selected as follows:
• level 1: all buttons are accessible
• level 2: all buttons are disabled except for:
- ON/OFF
- set temperature up/down
- fan speed
- cooling/heating mode
- enable/disable schedule timer
- air flow direction adjustment button
• level 3: all buttons are disabled except for:
- ON/OFF
- set temperature up/down
- fan speed
• user friendly HRV function, thanks to the introduction of a button for
ventilation mode and fan speed
• constantly monitoring of the system for malfunctions in a total of 80
components
• immediate display of fault location and condition
• reduction of maintenance time and costs.
Operation buttons:
• ON/OFF
• Timer mode start/stop
• Timer on/off
• Programmed time
• Temperature setting
• Air flow direction adjustment
• Operating mode selection
• Fan speed control
• Filter sign reset
• Inspection test/operation
Display:
• Operating mode
• Heat Recovery Ventilation (HRV) in operation
• Cool/heat changeover control
• Centralised control indication
• Group control indication
• Set temperature
• Air flow direction
• Programmed time
• Inspection/test operation
• Fan speed
• Clean air filter
• Defrost/hot start
• Malfunction

page
75
C
Centralised
Control Systems
Centralised control of the VRV system can be achieved via 3 user
friendly compact controls: centralised remote control, unified on/off
control and schedule timer. These controls may be used independently
or in combination where 1 group = several (up to 16) indoor units in
combination and 1 zone = several groups in combination.
A centralised remote control is ideal for use in tenanted commercial
buildings subject to random occupation, enabling indoor units to
be classified in groups per tenant (zoning).
The schedule timer programmes the schedule and operation
conditions for each tenant and the control can easily be reset
according to varying requirements.

DCS302C51
Centralised remote control
Providing individual control of 64 groups (zones) of indoor units.
• a maximum of 64 groups (128 indoor units, max. 10 outdoor units)
can be controlled
• a maximum of 128 groups (128 indoor units, max. 10 outdoor
units) can be controlled via 2 centralised remote controls in
separate locations
• zone control
• group control
• malfunction code display
• maximum wiring length of 1,000m (total: 2,000m)
• HRV air flow direction and air flow rate can be controlled
• expanded timer function

DCS301B51
Unified ON/OFF control
Providing simultaneous and individual control of 16 groups of
indoor units
• a maximum of 16 groups (128 indoor units) can be controlled
• 2 remote controls in separate locations can be used
• operating status indication (normal operation, alarm)
• centralised control indication
• maximum wiring length of 1,000m (total: 2,000m)

DST301B51
Schedule timer
Enabling 64 groups to be programmed
• a maximum of 128 indoor units can be controlled
• 8 types of weekly schedule
• a maximum of 48 hours back up power supply
• a maximum wiring length of 1,000m (total: 2,000m)

page
76
NEW
D
Daikin
Network Solutions

The ideal solution for control and management


up to 2,000 indoor units

DS-NET
adapter

PC for monitoring

Modem

Public phone
line RS485

Malfunction
RS232C

Modem

Max. of 10 DS-NET
adapters

Application area

• A small commercial area


of less than 40 indoor units.
• Critical applications for
centralized monitoring.

System layout Functions

• Allows monitoring and • Automates alarm • Schedule setup (Daily schedule)


control of up to up to (report messages) - Start/Stop
50 stores or sites and 2,000 for any malfunctions/errors. • Air conditioning malfunction
indoor units with just one Immediate report of any report
modem and phone line. indoor unit breakdown - Send message to
• Automates daily air to the servicing company. monitoring system
conditioning operation • Automatic report of • Manual operation
in order to free users from breakdown/ malfunction - Start/Stop, Set temperature,
the hassle of air conditioning information. Operation mode, Fan speed
operation/management. • Minimizes the • Status monitoring (Start/Stop,
• The daily schedule setting inconvenience of not having Set temperature, Operation
allows automatic operation air conditioning via rapid mode, Room temperature,
afterward. messages Operation time, Error code)

*DS-net can also be controlled via your mobile phone

page
77
Allows detailed & easy monitoring and operation of VRV systems
(max. 2 X 64 groups/indoor units).

Public
line

Onboard
AIRNET modem NEW
Fire alarm

Forced OFF contact input

PCMCIA
flash
memory

DIII-NET
• CSV output of
PPD (option) result

HRV
Indoor units
Pi-port

Onboard
Ethernet
DIO unit
port Links to the wattmeter when using
the PPD (option) function
Controls drain
pump lighting
etc.

NEW

NEW Malfunction Monitoring of


room enter/exit
sign

DI unit
Remote monitoring/control
via internet, e-mail

DIII-NET Allows monitoring/control


of up to 64 units (groups)
RS-232C of A/Cs and equipment

NEW
DIII-NET PLUS
adapter

Indoor unit HRV

page
78
Languages • Power Proportional Monitoring
Distribution: PPD (option)
• English • Easy management of • Visualisation via Graphical
• French electricity consumption User Interface (GUI)
• German NEW • Enhanced history function NEW • Icon colour display change
• Italian function
• Spanish • Indoor units operation
Control mode
NEW • Error messages via e-mail
System layout NEW • Individual control & mobile phone (option)
(set point, start/stop, • Indication filter
NEW • Up to 2 x 64 indoor fan speed) (max. 2 x 64 replacement
units can be controlled groups/indoor units) • Multi PC
NEW • Onboard Ethernet port NEW • Schedule control
(web browser + e-mail) (8 schedules, 17 patterns)
NEW • Digital i/o contacts • Flexible grouping in zones Cost performance
(option) • Yearly schedule
• Touch panel (full colour • Fire emergency stop • Labour saving
LCD via icon display) control • Easy installation
NEW • Interlocking control • Compact design:
(option) limited installation space
Management • Increased HRV monitoring • Overall energy saving
and control function
NEW • Web application & • Automatic cooling/heating
internet compatibility change-over Connectable to:
- Monitoring & control • Heating optimization
according to user • Temperature limit • VRV
- Remote monitoring NEW • Password security: • HRV
& control of more than 3 levels (general, • Sky Air
one building administration & service) (via interface adapter)
- Remote monitoring • Quick selection and full • Split
& control of more than control (via interface adapter)
one building via internet • Simple navigation

page
79
The ideal solution for control
and management of maximum
1,024 VRV indoor units.

System layout
[iPU] Intelligent Processing unit
• Up to 1,024 indoor units can 4 units
be controlled (by 4 iPUs) max.

• Ethernet TCPIP / 10 base/


T communication
· Operation Status Monitoring
• Integrated digital contacts on · Schedule Management
the Intelligent Processing Unit · Tenant Management
Unified
...etc
(iPU) on/off
control
· 19 general input ports
· 2 digital outputs
• Stand alone operation of the Fire alarm Security Centralised
remote
iPU for minimum 48 hours control

• Compatible with UPS


shutdown software
HRV

VRV System

Management Control Monitoring

• Proportional power • Individual control (setpoint, • Visualisation via a Graphical


consumption division start/stop, fan speed) (max. User Interface (GUI) featuring
• Operational history 1,024 indoor units) free layout
management (start/stop, • Group control (100 groups) • Operation mode of indoor &
malfunction, operation hours) • Schedule control (128 programs) outdoor units
• Generation of reports (graphics • Fire emergency stop control • Fault indication
& tables) (daily, weekly, (32 programs) • Indication filter replacement
monthly) • Interlocking control • Setpoint indication
• Peak load shedding • Setpoint limitation • Operation time monitoring
• Advanced tenant management • Automatic cool-heat change- • Multi PC
• Sliding temperature over • On-line help
• Eco mode • Power failure/release control
• Temperature limit (automatic
start)
• Timer extension

page
80
LONWORKS Networks
®

Compatible Gateway

• Interface for connection to


D
Daikin
Network Solutions

LON®
(FTT-10A)
LONWORKS® networks
• Communication via LON® ~
protocol (twisted pair wire)
• 64 units connectable per
DMS-IF
LON® BMS
• Unlimited site size
• Quick and easy installation
Unified
on/off
Fire alarm Security control
· Elevator
· Pump
· Lighting
...etc
~ Centralised
Power supply facility remote
control

HRV

VRV System

Integrated control system


connecting VRV system
with BMS system.
BACnet
• Interface for BMS system over ethernet

• Communication via BACnet ~


protocol (connection via
Ethernet)
• 256 units connectable per
BACnet gateway BMS

• Unlimited site size


• Easy and fast installation Unified
on/off
Fire alarm Security control
· Elevator
· Pump
· Lighting
...etc
~ Centralised
Power supply facility remote
control

HRV

VRV System

page
81
ACCESSORIES

CONTROL

SYSTEMS

1. INDIVIDUAL CONTROL SYSTEMS

DESCRIPTION FXZQ FXFQ FXCQ FXKQ FXDQ FXDQ-N FXSQ FXMQ FXUQ FXHQ FXAQ FXLQ FXNQ
Wired remote control BRC1D527
Infrared remote control cooling only BRC7E531W BRC7C513W BRC7C67 BRC4C63 BRC4C64 BRC4C64 BRC4C64 BRC4C64 BRC7C529W BRC7E66 BRC7E619 BRC4C64 BRC4C64
heat pump BRC7E530W BRC7C512W BRC7C62 BRC4C61 BRC4C62 BRC4C62 BRC4C62 BRC4C62 BRC7C528W BRC7E63W BRC7E618 BRC4C62 BRC4C62
Simplified remote control - - - - BRC2A51 BRC2A51 BRC2A51 BRC2A51 - - - BRC2A51 BRC2A51
Simplified remote control for hotel use - - - - BRC3A61 BRC3A61 BRC3A61 BRC3A61 - - - BRC3A61 BRC3A61

2. CENTRALISED CONTROL SYSTEMS

DESCRIPTION FXZQ FXFQ FXCQ FXKQ FXDQ FXDQ-N FXSQ FXMQ FXUQ FXHQ FXAQ FXLQ FXNQ
Centralised remote control DCS302C51
Unified ON/OFF control DCS301B51
Schedule timer DST301B51

3. OTHERS

DESCRIPTION FXZQ FXFQ FXCQ FXKQ FXDQ FXDQ-N FXSQ FXMQ FXUQ FXHQ FXAQ FXLQ FXNQ
Wiring adapter KRP1B57* EKRP1B2*5 EKRP1B2*5 KRP1B61 KRP1B61 KRP1B56 KRP1B61 KRP1B61 - KRP1B3 - KRP1B61 KRP1B61
Wiring adapter for electrical appendices (1) KRP2A52* KRP2A52* KRP2A51* KRP2A61 KRP2A51 KRP2A53 KRP2A51 KRP2A62 - KRP2A62* KRP2A61* KRP2A51 KRP2A51
Wiring adapter for electrical appendices (2) KRP4A53* KRP4A53* KRP4A51* KRP4A51 KRP4A51 KRP4A54 KRP4A51 KRP4A52 KRP4A53* KRP4A52* KRP4A51* KRP4A51 KRP4A51
Remote sensor KRCS01-1
Installation box for adapter PCB KRP1B101*2 KRP1C98 KRP1B96*3/4 - - KRP1B101 - - KRP1B97 KRP1C93*3 KRP4A93*3/4 - -
Electrical box with earth terminal (3 blocks) KJB311A - KJB311A
Electrical box with earth terminal (2 blocks) KJB212A - KJB212A
Noise filter (for electromagnetic interface only) KEK26-1 - KEK26-1
External control adapter for outdoor units DTA104A62* DTA104A62* DTA104A61* DTA104A61 DTA104A61 DTA104A53 DTA104A61 DTA104A61 - DTA104A62 DTA104A61 DTA104A61 DTA104A61
(must be installed on indoor units)
Option PCB for external electric heater, humidifier and/or hour meter*6 - - - - - - EKRP1B2 - - - - - -
Interface adapter for Sky Air series - - - - - - - - DTA102A52 - - - -
Forced ON/OFF connector - - - - - - - - EKF0F0 - - - -
Notes:
An installation box is required for each adapter marked with *
*2: Up to 2 installation boxes can be installed per indoor unit
*3: Only 1 installation box can be installed per indoor unit
*4: Up to 2 adapters can be fixed per installation box
*5: Hour meter
*6: Electric heater and humidifier are field supplied. These parts should not be installed inside the equipment.

4.

DESCRIPTION REFERENCE COMMENTS


DS-net adapter DTA113B51 4 units can be connected per adapter, 40 units when 10 adapters are connected
Software DPC001B1-B51 Monitoring panel software

page
82
5.

DESCRIPTION REFERENCE COMMENTS


Intelligent Touch Controller DCS601C51 2x64 units can be connected
Software DCS002C51 Power Proportional Distribution (PPD) software
DCS004A51 E-mail / Web software
Hardware DCS601A52 DIII NET-Plus adapter
Installation box KJB411A For wall mounted installation
Touch-Pen 1264009 Spare part n° of Touch-Pen for Intelligent Touch Controller
Interface adapters KRP928A2S For connection to Split units
DTA102A52 For connection to R-22 / R-407C Sky Air units
DTA112B51 For connection to R-410A Sky Air units
Digital input DEC101A51 Input contacts: 16 points
Digital input/output DEC102A51 Input contacts: 8 points; output contacts: 4 points

6.

DESCRIPTION REFERENCE COMMENTS


Intelligent Processing unit DAM602A51 256 indoor units per IPU
DAM602A52 128 indoor units per IPU
DAM602A53 192 indoor units per IPU
Software IM3.XX Up to 1,024 indoor units
Interface adapters KRP928A2S For connection to Split units
DTA102A52 For connection to R-407C/R-22 Sky Air units
DTA112B51 For connection to R-410A Sky Air units
DIII Ai DAM101A51 Outdoor temperature sensor
Digital input DEC101A51 Input contacts: 16 points
Digital input/output DEC102A51 Input contacts: 8 points, output contacts: 4 points

7.

DESCRIPTION REFERENCE COMMENTS


LONWORKS® networks compatible Gateway DMS504B51 Up to 64 units can be connected per DMS-IF
Interface adapters KRP928A2S For connection to Split units
DTA102A52 For connection to R-407C/R-22 Sky Air units
DTA112B51 For connection to R-410A Sky Air units

8.

DESCRIPTION REFERENCE COMMENTS


BACnet Gateway DMS502A51 64 units per Gateway
DIII board DAM411A1 Extension of 3 x DIII lines (3 x 64) indoor units
Digital input/output DAM412A1 For forced shutdown
Interface adapters KRP928A2S For connection to Split units
DTA102A52 For connection to R-407C/R-22 Sky Air units
DTA112B51 For connection to R-410A Sky Air units

9. BMS: BUILDING MANAGEMENT SYSTEM

DESCRIPTION REFERENCE COMMENTS


Parallel interface - Basic unit DPF201A51 enables ON/OFF command, operation and display of malfunction can be used in combination with up to 4 units.
Temperature measurement units DPF201A52 enables temperature measurement output for 4 groups; 0~5VDC."
Temperature setting units DPF201A53 enables temperature setting input for 16 groups; 0~5VDC."
Contact / analog signal

Unification adapter for DCS302A52 used for combining of air conditioning control computer and central remote controller
computerised control (ON/OFF, display)
Wiring adapter for KRP2A51 simultaneously controls air conditioning control computer and up to 64 groups of indoor units.
electrical appendices (1) KRP2A52
Wiring adapter for KRP4A51-53 to control the group of indoor units collectively, which are connected by the transmission wiring of
electrical appendices (2) remote controller.
External control adapter for outdoor unit DTA104A51 cooling/heating mode change over, demand control and low noise control are available between the plural
DTA104A52 outdoor units.
DIII-net expander adapter DTA109A51 a maximum of 10 outdoors or 128 indoors can be connected to 1 DTA109A51
a maximum of 8 DTA109A51 can be connected to DIII-net
Mounting kit KRP4A92 for easy installation of the DTA109A51

page
83
Daikin Europe N.V. is approved by LRQA for Daikin units comply with the European
its Quality Management System in accordance regulations that guarantee the safety of the
with the ISO9001 standard. product.
ISO9001 pertains to quality assurance regarding
design, development, manufacturing as well as
to services related to the product.

ISO14001 assures an effective environmental


management system in order to help protect VRV products are not within the scope of
human health and the environment from the the Eurovent certification programme
potential impact of our activities, products and
services and to assist in maintaining and
improving the quality of the environment.

Specifications are subject to change without


prior notice
Printed on non-chlorinated paper / Printed in Belgium