Professional Documents
Culture Documents
SYMBOL
SEA CHEST
CODE
SIZE
80A
GATE VALVE
40A
GATE VALVE
11
25A
GATE VALVE
20A
GATE VALVE
15A
GATE VALVE
40A
20A
DESCRIPTION
QTY
MATERIAL
40A
BELLMOUTH
32A
2
2
CAPACITY TANKS :
2
2
2
2
2
SEA CHEST
2.
3.
4.
5.
6.
:
4,29 M (100% FULL)
3
: 44,72 M (100% FULL)
3
: 44,58 M (100% FULL)
3
:
2,49 M (100% FULL)
3
:
2,49 M (100% FULL)
F.O.S.T.
FRESH WATER TANK
BALLAST TANK
L.O.T
D.O.T
20A
DUPLEX FILTER
ENGINE MOUNTED
40A
DUPLEX FILTER
ENGINE MOUNTED
10A
SIMPLEX FILTER
ENGINE MOUNTED
20A
SIMPLEX FILTER
40A
40A
2
2
2
1
2
10
GENSET MOUNTED
BRONZE WIRE OPERATED REMOTE SHUT-OFF FLG TO JIS 5K
50A
FLG TO JIS 5K
40A
NOTES :
1.
TYPE
TYPE
: A1
CAPACITY : 5 M3/H
HEAD
HEAD
: 3 BAR
: 1 BAR
20A
2.
F.O. TRANSFER PUMP IS TO BE CAPABLE OF BEING STOPPED FROM A POSITION WHICH WILL
ALWAYS BE ACCESIBLE AS WILL AS FROM THE COMPARTMENT ITSELF, EMERGENCY STOP TO
BE PROVIDED OUTSIDE ENGINE ROOM.
ALL QUICK CLOSING VALVES ARE TO HAVE SHUT DOWN DEVICE FREEBOARD DECK C/W
OPEN/ SHUT INDICATOR AND TO BE ADEQUATELY PROTECTED FROM MECHANICAL DAMAGE
& TO BE ATTACHED DIRECTLY TO THE TANK BULKHEAD. CAST IRON PRODUCTS WITH
ELONGATION LESS THAN 12% ARE NOT TO BE USED.
3.
DRIP PAN ARE TO BE PROVIDED UNDER F.O. PUMP, FUEL FILTERS, STRAINERS WHICH
REQUIRE OCCASIONAL EXAMINATION.
4.
5.
6.
ALL F.O. PIPES SHALL BE SEAMLESS BLACK M.S. SCH 40 (ASTM A53 GR.A OR EQUIVALENT)
7.
WHERE PIPING PENETRATES A W.T. BHD A DECK OR TANK TOP, AN ADEQUATE PENETRATION
FITTING IS TO BE PROVIDED TO ENSURE THE WATER TIGHTNESS OF THE STRUCTURE.
8.
ALL VALVES ARE TO BE EITHER OF THE RISING STEM TYPE OR FITTED WITH AN INDICATOR
TO SHOW WHETHER THE VALVES IS OPEN OR CLOSED.
9.
GENSET
M/E
40A
4
5
5
4
15A
10. FLEXIBLE CONNECTIONS BETWEEN ENGINES & PIPING TO BE OF HEAT & OIL RESISTANCE
MATERIAL & OF CLASS APPROVED TYPE (REINFORCED WITH WIRE BRAID OR SUITABLE MATERIAL).
20A
20A
15A
15A
20A
12. SUITABLE COAMINGS & DRAIN ARE TO BE PROVIDED TO COLLECT ANY LEAKAGE RESULTING
FROM FILLING OPERATION.
DRIP TRAY
20A
3 25A
13. MEANS TO PREVENT OIL FROM SPRAYING IS TO BE PROVIDED AT PIPE JOINTS AND
APPARATUSES (D 1.3.4 OF THE RULES).
15A
20A
40A
DRAIN
14. F.O. FITTING VALVES, V14 TO V28, ARE TO BE INSTALLED NEAR TO THE TOP OF F.O. TANKS.
1
M/E
GENSET
15. CALCULATION FOR CONSUMPTION FUEL OIL TANK FOR 2 MAIN ENGINE AND 2 GENSET
AT 100% LOAD MAIN ENGINE AND 100% AT GENSET IS 7,1206 TONNES/DAY.
16. CALCULATION FOR CONSUMPTION FUEL OIL TANK FOR 2 MAIN ENGINE AND 2 GENSET
AT 85% LOAD MAIN ENGINE AND 85% AT GENSET IS 6,0525 TONNES/DAY.
17. PORTABLE TYPE EMERGENCY FIRE PUMP PROVIDED ONBOARD COMPLETE WITH
INTEGRATED FUEL OIL TANK.
MATERIAL
STANDARD
DRAIN PIPE
PIPING
SIZE SCHEDULE
25 A
40
DRIP TRAY
20 A
40
FILLING PIPE
75 A
40
40 A
40
40 A
40
20 A
40
15 A
40
50 A
40