NORMATIV PRIVIND PROIECTAREA, EXECUTAREA I

EXPLOATAREA HIDROIZOLAIILOR LA CLDIRI (REVIZUIRE


NORMATIV NP 040-2002)
Contract:501/2011
Faza:

Redactarea:

Beneficiar:

MDRT

Director General INCD URBAN - INCERC,


conf.univ.dr.arh.Vasile Mei ___________________________________________________
Director tiinific Construcii INCD URBAN-INCERC,
dr.ing.Emil Sever Georgescu ___________________________________________________
Director Sucursal INCERC Bucureti,
ing.Claudiu Matei

___________________________________________________

ef Proiect,
conf.univ.dr.arh.Vasile Mei ___________________________________________________
ing.Sergiu Melinte

_________________________________________________________

- februarie 2013 -

Colectiv de specialiti

conf.univ.dr.arh.Vasile Mei
arh.Eugen Popescu
ing.Sergiu Melinte
arh.Vinceniu Toma
ing.Silviana Ursu
tehn.Cristian Arsene
Asociat ICECON SA
dr.ing.Adrian abrea
dr.ing.Ioan Pepenar
ing.Marinela Ghi
ing.Mircea Marian Arsene
ing. Dan Ion

CUPRINS
pag.
CAPITOLUL I:

Prevederi generale

CAPITOLUL II:

Prevederi privind proiectarea, executarea i utilizarea hidroizolaiilor

CAPITOLUL III:

Prezentarea i evaluarea hidroizolaiilor

16

CAPITOLUL IV:

Alctuirea structurilor hidroizolante

31

CAPITOLUL V:Condiii privind alctuirea i aplicarea structurilor termohidroizolante


ANEXA 1

44

Prezentare explicativ a structurilor hidroizolante i termohidroizolante


cu membrane bituminoase la tersase

48

Principii de alctuire ale principalelor tipuri de racorduri ntre suprafee


i la elemente de construcie cu membrane bituminoase la acoperiuri

54

Principii de hidroizolare a elementelor i prilor de cldire subterane


mpotriva exfiltraiilor i infiltraiilor

58

ANEXA 4

Prezentarea caracteristicilor auxiliare a produselor hidroizolante

62

ANEXA 5

Exemplificri privind aciunile mediului

64

ANEXA 6

Exemplificri privind ncrcri datorate suciunii vntului

67

ANEXA 7

Exemplificri privind evaluarea performanelor de izolare termic la


structurile termohidroizolante

69

Referine tehnice i legislative

78

ANEXA 2

ANEXA 3

ANEXA 8

NORMATIV PRIVIND PROIECTAREA, EXECUTAREA I EXPLOATAREA Indicativ:


HIDROIZOLAIILOR LA CLDIRI (REVIZUIRE NORMATIV NP 0402002)
Contract:
Faza:
Redactarea:
Beneficiar:

501/2011
1
I
MDRT

CAPITOLUL I: Prevederi generale


SECIUNEA 1: Obiect
Art.1
Prezentul normativ stabilete elemente caracteristice privind proiectarea, executarea i exploatarea
hidroizolaiilor la cldiri, n conformitate cu prevederile Legii 10/1995 privind calitatea n construcii
cu modificrile ulterioare, a HG 622/2004 privind stabilirea condiiilor de introducere pe pia a
produselor pentru construcii cu completrile i modificrile ulterioare, precum i a reglementrilor
europene.
Art.2
Prezentul normativ cuprinde:
a) prevederi generale i elemente definitorii privind hidroizolaiile;
b) prevederi privind proiectarea, executarea i exploatarea lucrrilor de hidroizolare;
c) cerine privind evaluarea hidroizolaiilor i materialelor hidroizolante;
d) principii i condiii privind alctuirea structurilor hidroizolante;
e) prevederi conexe;
f) anexe informative i explicative.

SECIUNEA a 2-a: Domeniul de aplicare


Art.3
Prevederile prezentului normativ se adreseaz proiectanilor, executanilor i beneficiarilor
(utilizatorilor), precum i verificatorilor i experilor tehnici, organelor de avizare i control, din
domeniul cldirilor civile, industriale i agricole.
Art.4
Prevederile prezentului normativ se refer la hidroizolaiile etane, continue i omogene ale cldirilor
supuse n general, aciunii mediului natural i antropic, supuse aciunii directe a apelor (n stare lichid
sau solid), neagresive chimic, cu sau fr presiune hidrostatic, ce acioneaz asupra cldirilor sau
prilor de cldire/construcie din exteriorul sau interiorul acestora.
Art.5
n prezentul normativ sunt cuprinse i specificaii asupra altor elemente ce fac parte din alctuirile
hidroizolante i care sunt n legtur cu acestea (structuri termoizolante ce fac parte din structurile
termohidroizolante).
Elaborat de:
INSTITUTUL NATIONAL DE CERCETARE-DEZVOLTARE IN CONSTRUCTII,
URBANISM SI DEZVOLTARE TERITORIAL DURABIL URBAN-INCERC
SUCURSALA INCERC BUCURETI

Aprobat de:
MINISTERUL DEZVOLTRII
REGIONALE I TURISMULUI
Cu ordinul nr.

Art.6
Prezentul normativ nu se refer la:
a) hidroizolarea acoperiurilor cu pant > 20%;
b) hidroizolarea la construcii speciale: drumuri i poduri, tuneluri, bataluri, gropi ecologice etc.;
c) sisteme de impermeabilizri n masa sau pe suprafaa elementelor de construcie (betoane, tencuieli,
ape, produse bentonitice, etc.)
d) sisteme de impermeabilizri ale solului;
e) sisteme de ecranri i drenaje ale prilor de construcii;
f) hidroizolaii rigide subterane;
g) caracteristicile de performan ale membranelor/foilor utilizate ca bariere contra vaporilor n
structurile termoizolante/termohidroizolante.
Art.7
Prezentul normativ nu se refer la reabilitri i reparaii ale hidroizolaiilor/termohidroizolaiilor
existente, degradate i nefuncionale. Acestea se vor prevede i executa n conformitate cu
reglementrile specifice, n vigoare, cu respectarea prevederilor privind cerinele eseniale de calitate
din prezentul normativ.
Art.8
Hidroizolaiile etane, continue i omogene care fac obiectul prezentului normativ se realizeaz cu:
a) membrane hidroizolante bituminoase;
b) membrane hidroizolante polimerice;
c) mase hidroizolante bituminoase omogene, cu aplicare pelicular;
d) mase hidroizolante polimerice, omogene, cu aplicare pelicular.

SECIUNEA a 3-a:

Elemente definitorii

Art.9
Terminologie general specific:
a) etaneitate: termen ce definete totala impermeabilitate fa de ap a unor suprafee, pri, elemente
sau produse din domeniul construciilor;
b) hidroizolaie: structura etan, continu i omogen de protecie a elementelor sau prilor de
construcie mpotriva infiltraiilor i/sau exfiltraiilor apei i/sau a umiditii naturale a solului;
c) hidroizolator: persoan calificat care execut activiti de etanare cu produse hidroizolante;
d) membrane (membrane hidroizolante): termen generic ce definete totalitatea produselor
hidroizolante sub form de foi groase ambalate n suluri;
e) mase omogene cu aplicare pelicular: termen generic ce definete totalitatea produselor
hidroizolante sub form fluid, cu diverse vscoziti;
f) terase necirculabile cu structur hidroizolant autoprotejat: terase necirculabile sau cu circulaie
ocazional, dirijat, care au ca strat superior al structurii hidroizolante o membran hidroizolant
autoprotejat (pentru acces ocazional se prevd zone special ntrite i marcate; de exemplu dale
din membran bituminoas, ntrit, autoprotejat);
g) terase necirculabile cu protecie suplimentar grea: terase necirculabile sau cu circulaie ocazional
(peste structura hidroizolant este prevzut o protecie grea din pietri, dale, ap, etc.);
h) terase circulabile pietonal: terase cu acces i/sau flux pietonal, cu utilizare redus sau intens;
i) terase carosabile: terase destinate accesului i parcrii autovehiculelor;
j) terase gradin: terase prevzute cu strat vegetal plantate n sistem extensiv, semi-extensiv sau
intensiv;
k) terase cu functiuni multiple;
2

l) terase cu structur termohidroizolant invers(ranversat): sunt de regul, terase necirculabile


(termoizolaia este aplicat pe structura hidroizolant);
m) armare (strat straturi de armare): materiale sub form de mpslituri (voaluri), folii, esturi, plase,
care se includ n structura membranelor hidroizolante (ncorporate i/sau aplicate pe suprafa) sau
care ntresc straturile hidroizolante din mase omogene cu aplicare pelicular;
n) autoprotecie (membrane hidroizolante autoprotejate): protecie cu materiale minerale (granulare
sau n paiete), folii sau pelicule aplicate n procesul de fabricaie pe faa superioar a membranelor
hidroizolante sau produse hidroizolante (membrane sau pelicule) rezistente la factorii de mediu prin
natura materialelor componente din care sunt fabricate;
o) aderen total: faa inferioar a produsului (structurii) hidroizolant este aderent, pe interaga
suprafa, la suport;
p) semiaderent (semiindependent): faa inferioar a produsului (structurii) hidroizolant este parial
aderent la suport:
(i)
cazul n care se aplic n aderen total pe o folie/membran perforat (pe un strat
de difuzie);
(ii)
cazul n care se lipete/sudeaz n puncte, benzi sau ploturi;
(iii)
cazul n care este prevzut cu ploturi, benzi autoadezive.
r)
independent (flotant) faa inferioar a produsului (structurii) hidroizolant se aplic pe suport
fr aderen:
(i) cazul n care se aplic pe un suport neamoesat;
(ii) cazul n care se aplic pe un suport de separare;
(iii)
n cazurile menionate produsul (structura) hidroizolant necesit lestare sau
fixare mecanic;
s) autoaderen: mod de aplicare a unei membrane n total aderen prin stratul autoadeziv aflat pe
faa inferioar a membranei;
t) strat de separare: folie sau foaie aplicat flotant ntre diverse produse ce compun structurile
termohidroizolante sau aplicat sub stratul de protecie grea, cu rol de a mpiedica aderena, de
compensare a deplasrilor i/sau de protec, de compensare a deplasrilor i/sau de protecie;
u) strat difuzie (difuzie): strat cu rol de repartizare uniform a vaporilor de ap (echilibrarea presiunii)
i de evacuare a acestora, poziionat, de regul, peste suprafee ce conin sau pot acumula umezeal;
v) barier contra vaporilor (barier vapori): strat cu rol de blocare a migrrii vaporilor de ap n
structura termoizolant (de regul de la interorul unei construcii spre exterior);
z) moduri de aderen a unui produs (structur) hidroizolant pe un suport:
(i)
cu bitum fierbinte sau cu mastic (adeziv) bituminos aplicat la rece;
(ii)
cu flacra sau cu aer cald (sudur);
(iii)
prin fixare mecanic, cu sau fr semiaderen.
Art.10
Suportul; element pe care se aplic hidroizolaia:
a) rigid: suport continuu, cu deformaii neglijabile pe care se pot aplica orice tip de produse/structuri
hidroizolante (planee/plci din beton armat, monolit sau prefabricat, plci prefabricate din beton
celular, betoane de pant, ape i tencuieli armate sau slab armate rectificate, din mortar de ciment
fr adaos de var acestea pot face parte din elementele structurale sau pot constitui elemente
aplicate pe structuri termoizolante; pe acest tip de suport se pot aplica produse/structuri
hidroizolante cu membrane sau din mase omogene cu aplicare pelicular, inclusiv straturi de difuzie
i/sau bariere contra vaporilor; acest tip de suport va fi amorsat cu produse specifice, compatibile cu
cele aplicate pe suport);
b) semirigid: suport alctuit din structuri termoizolante, pozate pe suport rigid, ce pot fi supuse unui
efort de compresiune de 8 N/cm2 (80kPa) cu o deformaie maxim de 10% (de exemplu: polistiren
3

expandat, plut aglomerat, poliuretan, poliizocianurat, etc.); pe acest tip de suport se pot aplica
produse/structuri hidroizolante cu membrane;
c) semielastic: suport deformabil alctuit din panouri metalice profilate longitudinal, panouri
complexe prefabricate, termoizolate, pleneu din elemente din lemn mbinate prin fal sau nut i
feder din plci fibrolemnoase montate prin alturare sau prin fal, cu sgeat maxim de 1/150
i/sau structuri termoizolante ce pot fi supuse unui efort de compresiune de 0,2 N/cm 2 (2kPa) cu o
deformatie maxim de 5%, cu un coeficient de revenire de minim 0,90 (de exemplu: plci din vat
mineral de minim 140 kg/m3) ce pot fi aplicate i pe suport rigid; pe acest tip de suport se pot
aplica produse/structuri hidroizolante cu membrane.
Art.11
Structura hidroizolant definete sistemul structural hidroizolant monostrat, bistrat sau multistrat
alctuit din produse hidroizolante tip membrane sau tip mase omogene cu aplicare pelicular,
bituminoase sau polimerice.
(1) Structurile hidroizolante cu membrane se aplic pe suport n urmtoarele moduri:
a) independent/flotant: simpl pozare pe elementul suport de regul, cu intercalarea unui strat de
separare (cu suprapunerile lipite); structurile hidroizolante se lesteaz;
b) n aderen total: prin lipire, la cald cu masticuri bituminoase, la rece cu adezivi/masticuri
bituminoase sau polimerice sau prin sudur cu flacra sau cu aer fierbinte;
c) n autoaderen: prin lipirea suprafeei inferioare, autoadezive a membranei pe suport, dup
ndeprtarea filmului de protecie;
d) n semiaderen: lipirea discontinu, n puncte sau benzi, de regul cu masticuri sau adezivi
specifici, la rece sau la cald, sau n autoaderen;
e) cu fixare mecanic: simpl pozare, n aderen total sau semiaderen, cu fixare mecanic pe
suportul structural (cu suprapunerile lipite/sudate, de regul, peste linia fixrilor mecanice);
(2) Membranele hidroizolante ce compun structurile multistrat se lipesc ntre ele (inclusiv
suprapunerile) numai n total aderen, la cald sau la rece (nu se admite lipirea prin autoaderen);
(3) Structurile hidroizolante monostrat cu membrane biruminoase i cele cu mase omogene cu aplicare
pelicular se aplic, numai pe suport rigid;
(4) Sisteme de termoizolare aplicate prin pulverizare n situ, peste structura hidroizolant (de exemplu:
spuma poliuretanic), un constituie hidroizolaie.
Art.12
Protecia sau autoprotecia structurilor hidroizolante cu membrane i cu mase omogene cu aplicare
pelicular expuse direct aciunii factorilor de mediu, au rolul principal de a ecrana radiaiile solare (n
special radiaiile UV) ce constituie principala cauz a degradrii membranelor hidroizolante, n timp,
prin mbtrnire natural.
(1) Autoprotecia membranelor hidroizolante bituminoase (aplicat din fabricaie pe faa superioar a
membranei):
a) granule, paiete minerale, hidrofobe;
b) folii metalice subiri (etirate, amprentate) din aluminiu, cupru, inox etc.
(2) Autoprotecia membranelor hidroizolante polimerice (aplicat din fabricaie pe faa superioar):
a) pulberi metalice sau nemetalice;
b) folii subiri metalice sau polimerice rezistente la radiaiile solare.
(3) Autoprotecia membranelor hidroizolante, bituminoase i polimerice, prin natura materialelor
componente i/sau prin structura de stratificare a materialelor cuprinse i/sau nglobate n masa
membranei;
(4) Autoprotecia maselor omogene, hidroizolante, cu aplicare pelicular, bituminoase i polimerice,
prin natura materialelor componente;
4

(5) Protecia (uoar) aplicat pe antier, pe structurile hidroizolante cu membrane sau mase omogene
cu aplicare pelicular, bituminoase i polimerice prin aplicarea, de pelicule protectoare;
(6) Protecia grea (ce poate constitui i strat cu rol de lestare), aplicat pe antier pe structurile
hidroizolante cu membrane sau cu mase omogene cu aplicare pelicular, bituminoase i polimerice
la terase cu pant de maxim 8%:
a) pietri mrgritar, sortat (< 15 mm), cu grosimea stratului 4 cm (70 kg/m 2) aplicat pe un strat
geotextil;
b) dale pozate n pat de nisip aplicat pe un strat geotextil;
c) dale din beton, piatr natural, gresie etc., pozate pe ap din mortar de ciment aplicat pe un
strat geotextil sau pozate n adeziv specific;
d) structur termohidroizolant, cu termoizolaia ranversat, acoperit cu protecie grea pozat pe
un strat de separare sau geotextil, acoperit cu protecie grea, deasemeni aplicat pe geotextil;
e) dale sau elemente lineare (tip duumea) montate pe ploturi distanier fixe sau reglabile;
f) structur teras grdin (strat drenant, strat filtrant, strat vegetal).
not: Protecia grea din punct de vedere al capacitii de lestare se va calcula i dimensiona ca
ncrcare n funcie de condiiile geometrice ale cldirii (nlime), poziia proteciei n
planul terasei (col, margine, coam, cmp) i de conditiile climatice (vnt dominant,
viteza maxim previzibil a vntului, creerea de turbioane, debit i vitez de iroire a
apelor pluviale, etc.);
(7) Protecii specifice hidroizolaiilor subterane (zidrii, ape sau tencuieli armate/slab armate, plci din
polistiren exterudat, foi polimerice semirigide amprentate, etc).
Art.13
(1) Structurile hidroizolante bituminoase i polimerice se vor aplica n conformitate cu prevederile
indicate de productorii de sistem privind hidroizolaiile (acetia indic, de regul, multiple variante
de structuri hidroizolante i termohidroizolante, pe suporturi diverse);
Art.14
Alctuirea structurilor hidroizolante bituminoase i/sau polimerice funcie de natura produselor
componente este, n general, indicat de productorii de sistem; de regul, structurile hidroizolante se
alctuiesc astfel:
a) n unul, dou sau mai multe straturi cu membrane bituminoase [de regul, alctuite din acelai
tip de bitum aditivat (APP cu APP, SBS cu SBS)];
b) ntr-un strat cu membran polimeric;
c) n dou sau mai multe straturi, cu o membran polimeric de baz (compatibil cu bitumul) i
unul sau mai multe straturi de membrane bituminoase (n conformitate cu prevederile
productorului membranei polimerice i/sau de sistem);
d) n dou sau mai multe straturi din mase omogene cu aplicare pelicular, bituminoase, fr sau
cu strat/straturi de armare;
e) n dou sau mai multe straturi din mase omogene cu aplicare pelicular, polimerice, fr sau cu
strat/straturi de armare;
f) n unul sau mai multe straturi din mase omogene cu aplicare pelicular, bituminoase sau
polimerice, fr sau cu straturi de armare i un strat de membran bituminoas sau polimeric
aplicat sub sau peste straturile peliculare (n conformitate cu prevederile productorului
maselor omogene cu aplicare pelicular i/sau de sistem).

Art.15
Agenii ce pot aciona asupra hidroizolaiilor, sunt:
a) mecanici: greuti proprii date din exploatare: greutile elementelor suprapuse peste structura
hidroizolant (betoane, ape, protecii grele), zpad, vnt, ocuri mecanice, presiuni ale maselor de
ap, cutremure, explozii, dilatri i contracii termice blocate;
b) electromagnetici: radiaii solare cu diferite lungimi de und (IR i UV), trsnete, cureni vagabonzi,
cmpuri magnetice, radiaii emise din procesul de exploatare/utilizare;
c) termici: variaii ale temperaturii mediului interior i exterior structurii hidroizolante, ocuri termice,
temperaturi ridicate i sczute, incendiu interior sau exterior structurii hidroizolante;
d) chimici: umiditatea aerului, a mediului de contact, apa meteoric i din procesul de
exploatare/utilizare, (solveni, acizi, baze i sruri din mediul exterior sau interior structurii
hidroizolante);
e) biologici: bacterii, mucegaiuri, vegetaii (rdcini), insecte i animale (roztoare, psri).

CAPITOLUL II:
SECIUNEA 1:

Prevederi privind proiectarea, executarea i utilizarea hidroizolaiilor


Prevederi privind proiectarea

Art.16
Principii generale:
(1) Documentaia tehnico-economic se va ntocmi n baza prevederilor Legii 10/1995 privind calitatea
n construcii, a Legii 50/1991 privind autorizarea lucrrilor de construcii i a HG 622/2004 privind
produsele pentru construcii, toate valabile cu completrile i modificrile ulterioare;
(2) Documentaia tehnic de execuie privind hidroizolarea (termohidroizolarea) cldirilor/prilor de
cldiri, mpotriva apei i/sau a umiditii mediului, se va ntocmi conform prevederilor prezentului
normativ i a reglementrilor tehnice specifice, n construcii, n vigoare, precum i n concordan
cu prevederile productorului/productorilor de sistem i de produse hidroizolante (i termoizolante
ce fac parte din structurile termohidroizolante);
(3) Documentaia tehnic de execuie privind structurile hidroizolante (termohidroizolante) se va
elabora, dup caz (funcie de amploarea, complexitatea i importana lucrrilor, precum i dup
necesiti i/sau cerine), distinct i explicit pentru structura/structurile hidroizolante sau
termohidroizolante, pe stadii fizice determinate, cu menionarea lucrrilor de alt specific i
corelarea acestora cu lucrrile de hidroizolare (termohidroizolare) nct s nu se produc
suprapuneri de lucrri sau s se prevad sisteme de protecie a lucrrilor executate (n cazul n care
suprapunerile de lucrri sunt inerente);
(4) Documentaia tehnic de execuie a lucrrilor de izolaii se va elabora n baza temei program
(analizate i nsuite de proiectant) i a caietului de sarcini (ntocmit de proiectant i nsuit de
beneficiar) ce va defini cerinele exigeniale de calitate pentru sistemul/sistemele i produsele
hidroizolante;
(5) Tema program i caietul de sarcini se vor elabora avnd n vedere:
a) condiiile i exigenele stabilite de beneficiar/utilizator;
b) precizarea funcionalitii i structurii constructive a cldirii/prii de cldire ce se izoleaz;
c) precizarea condiiilor geo-climatice de situare a cldirii i a condiiilor de utilizare;
d) precizarea tipului de hidroizolaie (termohidroizolaie) preconizate.
(6) Documentaia tehnic de execuie va cuprinde, dup caz, i prevederi/menionri privind lucrri
conexe izolaiilor (de exemplu: umpluturi, protecii, drenaje etc.);
(7) Pentru lucrrile de izolaii ce implic condiii de pericol privind incendiile, exploziile sau
accidentrile, se vor elabora documentaii specifice, distincte, privind securitatea i prevenirea
incendiilor i/sau exploziilor i de protecia muncii;
(8) Proiectantul poate opri lucrrile de construcie n cazul n care constat modificri sau abateri de la
prevederile documentaiei de execuie i/sau a reglementrilor specifice, n vigoare, asupra crora
nu a fost ntiinat i consultat.
Art.17
Principii particulare privind proiectarea izolaiilor la cldiri:
a) condiiile geoclimatice a sitului de amplasare a cldirii;
b) categoria i clasa de importan a cldirii;
c) definirea specificului funcional al cldirii/prilor de cldire, definirea din punct de vedere
constructiv/structural i a modului de comportare (deplasri, vibraii, micri elastice, nivel de
microfisurare) a acestora, ca element suport n vederea stabilirii tipului i alctuirii hidroizolaiei
(termohidroizolaiei);
d) aprecierea i stabilirea modurilor i nivelurilor de acionare medii-curente i maximprevizibile/poteniale a presiunii elementelor aplicate peste hidroizolaie, a vntului i a apei i/sau
a umiditii asupra hidroizolaiei (termohidroizolaiei);
7

e) definirea i stabilirea tipului structural i de produse hidroizolante (n cazul structurilor


termohidroizolante se va face corelarea privind alctuirea i dimensionarea structurii termoizolante
n conformitate cu reglementrile specifice, n vigoare; de exemplu posibilitatea acumulrii de
vapori;
f) stabilirea cerinelor i nivelurilor de performan necesare pentru tipul i structura hidroizolant
preconizat;
g) conceperea structurii hidroizolante/termo hidroizolante n aa fel nct, in limita posibilitilor, in
utilizarea cldurii, n timp, s se poat repara, reface structura hidroizolant cu manoper i costuri
ct mai reduse;
h) evaluarea vulnerabilitilor i stabilirea condiiilor de lucru, pe faze i etape de lucru;
i) stabilirea detaliilor, tipice i atipice, de etanare a diferitelor pri de construcie, n corelare cu
elementele constructive, anexe i accesorii specifice;
j) stabilirea tipurilor dimensionrii i nivelurilor calitative a elementelor anexe i accesorii a lucrrilor
de izolaii;
k) evidenierea fazelor i etapelor de lucrri i a consumurilor de produse/materiale aferente acestora
precum i a vulnerabilitii;
l) stabilirea condiiilor privind verificarea calitii lucrrilor, pe stadii fizice, precum i, dup caz, de
urmrirea comportrii n utilizare.
Art.18
Condiii de calitate, asigurate prin proiectare, pentru satisfacerea cerinelor eseniale:
(1) Rezisten mecanic i stabilitate: se exprim prin condiii tehnice privind sigurana constructiv i
de utilizare a structurilor hidroizolante (termohidroizolante), precum i a prilor de construcie pe
care acestea sunt aplicate i a elementelor suprapuse peste acestea n ansamblu, la toate
combinaiile de aciuni susceptibile de a se produce n timpul utilizrii (existenei). Aceast cerin
cuprinde urmtoarele condiii tehnice i criterii (parametri) de performan aferente:
a) aptitudinea de exploatare:
(i) limitarea deformaiilor i/sau degradrilor sub aciunea sarcinilor verticale, pozitive i/sau
negative, uniform repartizate i/sau concentrate avnd drept criteriu de performan
stabilitatea fa de suport cu meninerea etaneitii;
(ii) limitarea deformaiilor i/sau a degradrilor produse prin deplasrile (deplasri, ncovoieri
cu sgeat limitat, vibraii, dilatri, contracii etc.) suportului i/sau a elementelor
suprapuse, sub aciunea sarcinilor verticale i/sau orizontale, uniform repartizate i/sau
concentrate sau sub efectul variaiilor termice avnd drept criterii de performan rezistene
la pliere (la temperaturi sczute), rezistena la perforare static i dinamic, rezistena la
rupere la traciune, alungirea la rupere la traciune, rezistena la dezlipire i forfecare a
mbinrilor, stabilitate la temperaturi ridicate, stabilitate dimensional etc.
b) capacitatea de rezisten i stabilitate: evitarea deformaiilor i/sau degradrilor sub efectul
suciunii i presiunii vntului prin asigurarea aderenei la suport sau a unei lestri
corespunztoare (inclusiv protecie grea), avnd drept criteriu de performan aderena la suport
(inclusiv rezistena la smulgere a elementelor anexe i accesorii);
c) durabilitatea structural: meninerea calitilor funcionale fa de agenii ce pot aciona asupra
izolaiei avnd drept criteriu de performan durata de garanie (durata de utilizare estimat);
d) proiectarea prilor de construcie ce se izoleaz, precum i calculul aciunilor directe asupra
izolaiilor se va face n conformitate cu prevederile Normativului P 100-1/2006 Cod de
proiectare seismic Partea 1 Prevederi de proiectare pentru cldiri, CR 1-1-3-2005 Cod de
proiectare. Evaluarea aciunii zpezii asupra construciilor, NP 082-2004 Cod de proiectare.
Bazele proiectrii i aciunii asupra construciilor. Aciunea vntului, NP 00-2003 Normativ
privind proiectarea construciilor din lemn i a Standardelor SR EN 1991-1-1:2004 Eurocod
8

1: Aciuni asupra structurilor. Partea 1-1: Aciuni generale. Greuti specifice, greuti proprii,
ncrcri utile pentru cldiri, SR EN 1991-1-1:2004/AC:2009 i a SR EN 1991-11:2004/NA:2006 Eurocod 1: Aciuni asupra structurilor. Partea 1-1: Aciuni generale. Greuti
specifice, greuti proprii, ncrcri din exploatare pentru construcii. Anex naional.
(2) Securitatea la incendiu: se exprim prin condiii tehnice privind ansamblul proprietilor produselor
i materialelor ce compun izolaiile n relaie cu structura suport privind iniierea, reacia i
propagarea unui incendiu:
a) respectarea prevederilor stipulate n Normativ de siguran la foc a construciilor;
b) performanele de comportare la foc interior i exterior (clase de reacie la foc, de rezisten la
foc i de performan la foc exterior):
(i) izolaiile aflate n contact direct cu mediul vor ndeplini cerinele privind performana la
foc ca element cu rol de separare a focului din interior, potrivit prevederilor din
reglementrile de securitate la incendiu (Regulament privind clasificarea i ncadrarea
produselor pentru construcii pe baza performanelor de comportare la foc, aprobat cu
Ordinul ministrului transporturilor, construciilor i turismului i ministrul administraiei i
internelor nr. 1822/394/2004, cu modificrile i completrile ulterioare;
(ii) pentru nvelitorile alctuite din structuri hidroizolante (termohidroizolante) se pun condiii
privind performanele nvelitorilor/acoperiurilor expuse la foc exterior (posibilitatea
contactului dintre izolaie i foc exterior deschis: scntei, corpuri incandescente, igar
aprins) n concordan cu prevederile din SR ENV 1187:2003 (metode de ncercare a
acoperiurilor la expunerea la foc exterior) i SR EN 13501-5+A1:2010 (clasificare la foc
a produselor i elementelor de construcii, n baza rezultatelor ncercrilor de expunere la
foc exterior);
(iii) elementele suport combustibile din lemn (astereal, cpriori, pane, ipci etc.) vor fi
protejate de foc, pasiv sau reactiv, pentru respectarea condiiilor minime de ncadrare n
gradul de rezisten la foc/nivelul de stabilitate la foc;
(iv) pentru panourile de nvelitoare i pentru suportul nvelitorii se impun cerine privind clasa
de reacie i de rezisten la foc, potrivit reglementrilor privind securitatea la incendiu (la
stabilirea gradului de rezisten la foc/nivelului de stabilitate la foc a construciilor, privind
luarea n considerare sau nu a nvelitorilor, se vor ndeplini cerinele reglementrilor
privind securitatea la incendiu);
(v) proiectarea, instalarea i punerea n funciune a courilor de fum (strpungeri fierbini) se
realizeaz n conformitate cu SR EN 15287-1+A 1:2011 Couri de fum. Proiectare,
instalare i punere n funciune a courilor de fum. Partea 1: Couri de fum pentru aparate
de nclzire neetane i SR EN 15287-2:2008 Couri de fum. Proiectare, instalare i
punere n funciune a courilor de fum. Partea 2: Couri de fum pentru aparate de nclzire
etane;
(vi) proiectarea instalaiilor de paratrsnet n conformitate cu Normativul privind protecia
construciilor mpotriva trsnetului.
c) propagarea incendiului: n cazul nvelitorilor combustibile cu suprafee mari (n acelai plan), se
vor prevedea bariere sau zone incombustibile care s limiteze propagarea incendiului;
d) aciunea fiziologic: n cazul producerii unui incendiu, produsele de combustie (fum i gaze
rezultate din ardere) s nu afecteze utilizatorii (n timpul calculat pentru evacuare) prin efecte
asupra ochilor, cilor respiratorii i pielii;
e) prevenirea incendiilor isau a exploziilor datorate produselor hidroizolante inflamabile la
punerea n oper a hidroizolaiilor n spaii nchise i/sau slab ventilate.
(3) Sigurana n exploatare: se exprim prin condiii tehnice privind sigurana n exploatare la toate
aciunile maxime ce decurg din activitatea uman i aciuni ale mediului, susceptibile a se produce
9

n timpul utilizrii. Aceast cerin cuprinde urmtoarele condiii tehnice aferente izolaiilor aflate
n contact direct cu mediul i a componentelor/accesoriilor acestora:
a) sigurana n utilizare: comportarea la aciuni asupra izolaiilor n cazul lucrrilor de ntreinere,
avnd drept criteriu de performan rezistena la perforare static i dinamic inclusiv la ocuri
provocate de grindin;
b) prevenirea alunecrii (la circulaie ocazional): pentru nvelitori cu pant mai mic de 30% nu
este necesar prevederea de elemente suplimentare de siguran, dar se vor prevedea puncte de
asigurare (ancorare), pentru legarea centurii de siguran i sisteme de bordare (parapei,
balustrade) n zonele cu goluri cu risc de cdere de la nlime (pentru nlimi > 3 m), precum
i prevederea pe zonele de circulaie (inclusiv ocazional) cu dalaje antiderapantede n planul
dat;
c) comportarea la ageni climatici (variaii de temperatur, umiditate, radiaii solare): stabilitate
dimensional la variaii de temperatur, rezisten la gelivitate, rezisten la radiaii solare
(IR, UV);
d) rezisten la coroziune electrochimic a elementelor accesorii, anexe i a sistemelor de ancorare:
se va evita contactul direct ntre urmtoarele metale: zinc-fier (oel); zinc-cupru; fier (oel)cupru; aluminiu-fier; aluminiu-staniu (cositor); aluminiu-cupru; aluminiu-plumb; aluminiu-zinc;
e) protecia la atacul agenilor biologici (ciuperci, mucegaiuri, roztoare, psri, insecte etc.).
(4) Igien, sntate i mediu: se exprim prin nivelul apariiilor i degajrilor de substane nocive sau
insalubre (gaz, lichid, praf, mucegai, ciuperci etc.) pe suprafaa interioar i/sau exterioar a
izolaiilor:
a) pe durata exploatrii nu se admit apariii i degajri de substane nocive (toxice) i/sau
insalubre;
b) pe durata execuiei, se vor adopta msurile de prevenire, protecie i securitate a muncii (n
special pentru lucrri executate n spaii nchise, neventilate).
(5) Protecia mpotriva zgomotului:
a) izolare la zgomot aerian: se exprim prin condiii tehnice de atenuare a zgomotului aerian
provenit din exterior i/sau interior (exprimat pe domeniu de frecvene) avnd drept criteriu de
performan nivelul de izolare la zgomot;
b) zgomotul emis de elementele de acoperi/nvelitoare: cuprinde zgomotele emise spre interior,
raportate la zgomotul (interior) de fond; zgomotele emise de acoperis sunt produse de variaiile
dimensionale ale elementelor de construcie, de vibraiile i uierturile produse de nvelitoare
sub efectul vntului (vnt cu vitez mai mare de 10 m/s) i de impactul ploii i grindinei pe
nvelitoare.
(6) Economia de energie i izolare termic:
a) economia de energie: posibilitatea echiprii acoperiului cu elemente/instalaii pentru
producerea de energie termic i/sau electric;
b) izolare termic: prevederea structurilor termohidroizolante, eficiente ce pot conferi performane
privind izolarea termic (produse/materiale cu rezisten la transfer termic) i sau ce pot
diminua ocul termic (suprafee termoreflectante).

SECIUNEA a 2-a:

Prevederi privind execuia

Art.19
Condiii generale:
(1) Execuia lucrrilor de hidroizolaii (termohidroizolaii) se va desfura cu respectarea prevederilor
Legii 10/1995 privind calitatea n construcii, a Legi 50/1991 privind autorizarea lucrrilor de
construcii, a HG 28/2008 privind documentaia tehnico-economic i a HG 622/2004 privind
produsele pentru construcii, toate valabile cu completrile i modificrile ulterioare;
10

(2) Lucrrile se vor executa de ctre firme cu experien n domeniu, cu personal calificat
(hidroizolator, tinichigiu, etc.);
(3) Executantul va prelua frontul de lucru n baza procesului verbal, cu ndeplinirea tuturor exigenelor
impuse de natura lucrrilor, de prevederile documentaiei documentaiei i a reglementrilor
specifice;
(4) nceperea lucrrilor va fi precedat de organizarea de antier, n special privind asigurarea
acceselor, a zonelor de depozitare i de adoptarea msurilor ce se impun de protecie a muncii i de
prevenire a incendiilor;
(5) Lucrrile se vor executa n conformitate cu condiiile i prevederile documentaiei tehnicoeconomice de execuie i a reglementrilor specifice n vigoare; orice necocordan sau omisiune
vsa fi semnalat spre rezolvare proiectantului de specialitate cu ntiinarea beneficiarului;
(6) Executantul va ntocmi mpreun cu beneficiarul (i cu proiectantul) procese verbale privind
diversele faze ale execuiei, n special pentru lucrrile ascunse;
(7) Procurarea materialelor i accesoriilor aferente se va face conform nivelurilor de calitate prevzute
n documentaia tehnic-economic de execuie i/sau n caietul de sarcini;
(8) Lucrrile propriu-zise de execuie a nvelitorii vor fi precedate de ndeprtarea din zona de lucru a
tuturor materialelor i deeurilor inflamabile i/sau combustibile;
(9) Nu se va ncepe execuia fr o documentaie complet i/sau montajul privind toate elementele ce
strpung izolaia i/sau a elementelor ce vor fi pozate peste izolaie;
(10) La terminarea execuiei se vor ntocmi formele de recepie a lucrrii (cu eventuale observaii ce
vor fi nsuite i operate de executant) n baza constatrilor i verificrilor efectuate de o comisie
alctuit conform legislaiei n vigoare.
Art.20
Condiii privind pregtirea lucrrilor:
(1) Pentru lucrrile de amploare i de complexitate ridicat (recomandabil pentru suprafee > 500 m 2),
nainte de nceperea acestora, este util ca executantul s elaboreze o documentaie/fi tehnic
privind pregtirea acestora (rezolvarea detaliilor ce nu se regsesc n documentaia de execuie i a
unor eventuale neconcordane sau modificri, n acord cu proiectantul) i elaborarea graficului de
ealonare a lucrrilor (pentru a nu suprapune cu lucrri de alt specific), organizarea de antier/punct
de lucru precum i msurile de protecie i siguran, specifice lucrri;
(2) Organizarea de antier i punerea acesteia n practic:
a) asigurarea spaiului i utilitilor aferente organizrii de antier;
b) protecia muncitorilor privind spaiile de acces n cldire, a spaiilor perimetrale e circulaie i
asigurarea zonei de lucru (plase, parapei, schele, etc.);
c) asigurarea branamentelor de ap i energie electric, inclusiv a mijloacelor de ridicat.
Art.21
Condiii climatice:
Lucrrile de izolaii se vor desfura n condiii climatice normale, adecvate (fr vnturi puternice sau
ploaie, la temperaturi pozitive (>50 C), conform prevederilor tehnologice.
Art.22
Condiii referitoare la suport i de preluare a frontului de lucru:
(1) Suportul pe care se aplic izolaia va corespunde specificaiilor din documentaia tehnicoeconomic de execuie;
(2) Suportul pe care se aplic izolaia va fi curat, desprfuit i degresat;
(3) Nivelul maxim al umiditii suportului, pentru hidroizolaii aplicate n tabl aderent sau
semiaderent cu membrane bituminoase i polimerice i cu mase omogene cu aplicar pelicular
bituminoase va fi conform recomandrilor productorului i se recomand s fie:
11

a) 12% pentru beton, elemente prefabricate din beton, ape, tencuieli (din mortar de ciment fr
adaos de var) i pentru elemente din beton celular sau spumat;
b) 15% pentru plci celulozice aglomerate, perlit i gipscarton;
c) 20% pentru lemn;
d) Nivelul maxim al umiditii suportului pentru hidroizolaiile cu mase omogene cu aplicare
pelicular polimerice va fi conform recomandrilor productorului, variind funcie de produs,
ntre 2% i 10 %.
(4) Suprafaa suportului rigid trebuie s fie plan, cu denivelri de maxim 5 mm (determinate cu
dreptarul de 2 m lungime aplicat pe direcia de planeitate) i nu va prezenta neregulariti (bavuri,
excrescene, denivelri), convexe sau concave mai mari de 2 mm (determinate cu o rigl de 20 cm
lungime, deplasat pe direcia de planeitate); denivelrile se vor ciopli sau rectifica, cu rini
sintetice sau cu mortar de ciment aditivat (cu plastifiani);
(5) Nu se admit denivelri mai mari de 10 mm ntre elemente suport prefabricate; denivelrile se vor
rectifica cu mortar de ciment aditivat (cu plastifiani), crendu-se o pant de racord de maxim 1/5;
(6) Suportul nu trebuie s prezinte fisuri, n planul suprafeei, mai mari de 1,5 mm (determinate prin
calcul) sub aciunea tuturor ncrcrilor i deformaiilor previzibile, stabilite;
(7) Suportul cu pante generale > 2% vor fi rectificate, astfel ca dup aplicarea izolaiei s nu se formeze
stagnrii locale de ap mai mari de 1 m 2, cu grosimea stratului de ap de maxim 1,5 cm; pentru
suprafee orizontale sau cu pante < 2% se admit stagnri locale de ap pe suprafee limitate (se
recomand maxim 4 m2)cu grosimea stratului de ap de maxim 2 cm; stagnrile de ap nu vor
depi 5% respectiv 10% din suprafaa teraselor;
(8) Muchiile orizontale i verticale, ieinde sau intrnde, se vor realiza n unghi drept sau cu racord la
450 (recomandabil, cu ipotenuza de 10 cm) i nu se vor prezenta neregulariti (bavuri) mai mari de
2 mm determinate cu rigla de 20 cm lungime i denivelri (n special n lungul liniei de intersecie a
planurilor) mai mari de 5 mm determinate cu dreptarul de 2 m lungime; aceste condiii se vor
respecta i n cazul liurilor de ancorare-protecie a terminaiilor verticale a membranelor
hidroizolante. Nu se recomand realizarea scafelor semirotunde. Se pot utiliza scafe cu racord la
450, prefabricate, la hidroizolaiile mpotriva apelor fr presiune hidrostatic;
(9) Se va verifica corecta poziionare i montare a tuturor elementelor constructive, accesorii i anexe
la care se racordeaz hidroizolaia (receptoare pluviale, barbacane/garguie, strpungeri, bae,
elemente de fixare i auxiliare, etc.);
(10)
Nu se va prelua frontul de lucru fr certitudinea i verificarea corectitudinii existenei
tuturor elementelor de fixare, ancorare, racordare privind suportul i a celor de strpungere,
fixare, ancorare a instalaiilor ce strpung i trec prin izolaie precum i celor ce vor fi
pazate/montate peste izolaie;
(11)
Nu se vor aplica structuri hidroizolante:
a) pe dale aplicate n ap sau n pat de nisip;
b) pe structur termohidroizolaie invers cu termoizolaie din spum poliuretanic aplicat n
situ;
c) pe structur hidroizolant/termohidroizolant veche, degradat ce nu a fost reparat,
rectificat, regenerat (insclusiv luarea msurilor de eliminare a umiditii/apei din stratura
existent).
Art.23
Condiii de punere n oper:
(1) Se vor respecta reglementrile specifice cerinelor eseniale de calitate menionate la Art.18;
(2) Montarea structurilor i produselor/materialelor hidroizolante se va face pe zone i sensuri
determinate, inndu-se seama, n special de direcia vntului dominant, de pante, de cile de acces,
12

transport i de manipularea materialelor, fr afectarea zonelor cu lucrri n curs de execuie sau


terminate;
(3) Se vor lua msuri ca dotrile de lucru (utilaje de ridficat, butelii, containere, palei, dispozitive de
transport, etc.) s nu deterioreze suportul sau suprafeele izolate.
Art.24
Condiii privind securitatea la incendiu:
(1)
Se vor respecta prevederile reglementrile n vigoare prezentate la Art.18 (2) precum i
msurile de aprare mpotriva incendiilor prevzute de Norme generale de aprare mpotriva
incendiilor, aprobate cu Ordinul ministrului administraiei i internelor nr.163/2007, a
reglementrilor privind prevenirea i stingerea incendiilor pe durata executrii lucrrilor de
construcii i instalaii aferente acestora, precum i susinerea instructajelor specifice domeniului;
(2)
Msurile necesare pentru prevenirea i stingerea incendiilor se vor lua la punctul de lucru, n
zonele adiacente i de depozitare, n special la lucrrile n care se utilizeaz foc deschis sau aparate
de sudur; totodat, nainte de nceperea lucrrilor propriu-zise de izolaii se vor ndeprta toate
materialele i/sau deeurile combustibile;
(3)
Se vor respecta prevederile privind instalaiile electrice (tablouri electrice, prize, conductori,
etc.).
Art.25
Condiii privind protecia i igiena muncii:
(1) Se vor respecta prevederile reglementrilor privind protecia i igiena muncii n construcii,
prezentate la Art.18(4) i a celor din Legea 319-2006 privind securitatea i sntatea n munc, a
HG 1091-2006 privind cerinele de securitate i sntate la locul de munc, a HG 971-2006 privind
cerinele minime pentru semnalizarea de securitate i/sau de sntate la locul de munc, precum i
susinerea instructajelor specifice domeniului;
(2) Se vor asigura cile de acces orizontale i verticale, a golurilor i a zonelor de lucru mpotriva
accidentelor, cderilor de la nlime, etc.;
(3) Se vor utiliza numai scule, unelte i utilaje n perfect stare de funcionare;
(4) Se vor respecta condiiile privind lucrul la nlime (i n apropierea golurile) iar lucrtorii vor fi
atestai medical periodic apt pentru lucrul la nlime;
(5) Se vor respecta condiiile de siguran la montarea i utilizarea schelelor i a mijloacelor de ridicat;
(6) Se vor lua msurile ce se impun privind ndeprtarea deeurilor i sortarea acestora pe categorii de
materiale n vederea reciclrii;
(7) Dispozitivele, utilajele, uneltele acionate electric vor fi mpmntate i alimentate prin conductori
continui asigurai i racordai la tablouri electrice verificate, mpmntate;
(8) Se vor lua msurile necesare pentru a preveni acumularea gazelor toxice i/sau inflamabile n
spaiile de lucru, nchise/seminchise.
Art.26
Condiii privind calitatea lucrrilor:
(1) Recepia produselor/materialelor de izolaie se face prin verificarea certificatelor de conformitate,
termenele de valabilitate (unde este cazul) i de garanie emise de productor pentru fiecare lot de
produse/materiale, conform regulilor specifice pentru verificarea calitii i a prevederilor prezentei
reglementri i n conformitate cu prevederile din Caiet de sarcini (dup caz); n unele situaii se
pot solicita analize de laborator (laboratoare autorizate, acreditate) care s verifice/certifice
nivelurile de calitate;
(2) Pstrarea i depozitarea materialelor de nvelitoare: condiiile de pstrare i depozitare a produselor
sunt precizate de productorii acestora n fiele tehnice de produs:
13

a) n depozite, trebuie, de regul, respectate urmtoarele condiii privind depozitarea: produsele


din mase omogene cu aplicare pelicular se depoziteaz n pachete sau n palei , iar
membranele hidroizolante se depoziteaz sub form de suluri (n poziie vertial) pe platforme
sau palei, n spaii acoperite;
b) la punctul de lucru depozitarea se va face n aceleai condiii ca n depozite, dar fr
obligativitatea spaiilor acoperite (acoperite de protecie provizorie; de ex.: prelate).
(3) Controlul calitii la punerea n oper: la punerea n oper a materialelor/produselor se efectueaz
controlul (vizual) asupra meninerii integritii, calitii i manipulrii acestora ca urmare
depozitrii;
(4) Recepia lucrrilor de izolaii se va face n conformitate cu prevederile reglementrilor tehnice n
vigoare.
Art.26
Controlul privind execuia:
(1) Verificri pe parcursul lucrrilor:
a) calitatea suportului (calitatea produselor/materialelor i execuiei);
b) calitatea produselor / materialelor ce compun structurile izolante (hidroizolante /
termohidroizolante);
c) poziionarea i fixarea n structura suport a pieselor nglobate, de trecere (a elementelor de
strpungere) de fixare, ancorare, etc.;
d) calitatea execuiei pe etape/faze de lucru, n concordan cu prevederile documentaiei tehnice
de executie i a specificaiilor tehnice.
(2) Rectificri:
a) rectificri locale, unde este cazul, pe etape/faze de lucru;
b) n vederea verificrii finale sau ca urmare a acesteia se vor executa rectificri a eventualelor
deficiene precum i de finisare (unde este cazul).
(3) Verificri finale:
a) verificarea de suprafa se va realiza vizual i prin tatonare, urmrind corectitudinea i calitatea
modului de aplicare, lipire, fixare, racordare, acoperire, asigurare i de protecie a
produselor/materialelor de izolaie;
b) verificarea documentelor (procese verbale) privind controalele de calitate efectuate pe parcursul
desfurrii lucrrilor;
c) verificaera etaneitii (unde aceasta este posibil, de regul la terase cu pante reduse) prin
inundare timp de 72 de ore.
Art.28
Garania asupra execuiei:
(1) Garantarea execuiei corespunde calitii materialelor componente structurii izolante i manoperei
de realizare;
(2) Garania de sistem acordat lucrrilor va corespunde cel puin garaniei minime oferite de
productor pentru produsele de nvelitoare (de regul, 10 ani); se poate acorda garania diferenial
pentru izolaie i produsele componente sistemele.
Art.29
Durabilitatea apreciat n utilizare constituie un criteriu estimativ care este indicat, de regul, de
productorii de sisteme, stabilit prin urmrirea n timp a bunei comportri n utilizare a produselor
izolante puse corect n oper.
Art.30
Msuri de ntreinere i condiii de utilizare/exploatare:
14

(1) Msuri de ntreinere:


a) msurile de ntreinere periodic constau, dup caz, n aciuni anuale sau semestriale, (de regul
la sfritul toamnei i/sau nceputul primverii); acestea constau n general din lucrri de
verificare i curire a traseelor de scurgere, colectare i evacuare a apelor meteorice i, dup
caz, de reparare a elementelor accesorii, izolaiei;
b) msuri de reparare/ntreinere necesare n cazul unor deteriorri/efeciuni aprute din utilizarea
defectuoas a izolaiei sau din cauze naturale, accidentale, imprevizibile.
(2) Condiii de utilizare/exploatare:
a) corecta utilizare n timp a izolaiei, numai n scopul funcional pentru care a fost prevzut, cu
respectarea msurilor de ntreinere executate;
b) orice intervenie sau utilizare neconform, conduce la anularea garaniei acordate i poate
prejudicia funcionarea corect a izolaiei;
c) orice intervenie, preconizat, se va face cu acordul proiectantului de specialitate , de ctre, cu
acordul, sau sub supravegherea executantului care a emis certificatul de garanie).

SECIUNEA a 3-a: Urmrirea comportrii n exploatare a izolaiilor


Art.31
Urmrirea comportrii n exploatare se va face n conformitate cu prevederile reglementrilor tehnice
specifice, n vigoare, n cazurile cnd acestea sunt direct vizibile. Prin aceasta se urmrete buna
funcionare a etaneitii n timp i aprecierea durabilitii precum i luarea msurilor preventive de
ntretinere, regenerare i reparatii.
Art.32
Asigurarea urmririi comportrii n timp, n condiii normale de utilizare a izolaiilor se face prin grija
beneficiarului, o dat pe an; acest interval poate fi modificat n funcie de condiiile concrete pentru
fiecare caz n parte, astfel:
a) intervalul poate fi mrit dac la dou verificri succesive nu se constat degradri ( nu la lucrri cu
vechime mai mare de 10 ani);
b) intervalul poate fi micorat pentru izolaiile la care degradrile ar conduce la deteriorarea unor
echipamente speciale (camere comand, staii electrice, camere de calcul, etc.);
c) intervalul poate fi micorat pentru izolaiile ce au fost supuse la sarcini, ocuri sau micri
(deplasri) neprevzute (seism, accidente mecanice, etc.).

15

CAPITOLUL III: Prezentarea i evaluarea hidroizolaiilor


SECIUNEA 1: Cerine, condiii i criterii generale de calitate
Art.33
Prevederi privind cerine de calitate, condiii tehnice i criteriile de performan la care trebuie s
rspund urmtoarele categorii de hidroizolaii:
a) hidroizolarea, acoperiurilor i prilor de cldiri supuse direct aciuni apelor meteorice;
b) hidroizolarea elementelor sau prilor de cldiri mpotriva exfiltraiilor i/sau infiltraiilor datorate
apelor fr presiune hidrostatic;
c) hidroizolarea elementelor sau prilor de cldiri, amplasate suprateran i/sau subteran mpotriva
exfiltraiilor i acelor amplasate subteran mpotriva infiltraiilor, contra apelor cu presiune
hidrostatic.
Art.34
Hidroizolarea acoperiurilor i prilor de cldiri supuse direct aciunii apelor meteorice i, direct sau
indirect, supuse aciunii celorlali factori de mediu, aplicat, de regul, pe toate tipurile de suport.
(1) Obiect de referire:
a) acoperiuri-teras si pri de cldiri, cu panta general cuprins ntre 0% (inclusiv) i 1,5%;
acestea se vor prevede cu urmtoarele condiii:
(i) numai pe suport rigid;
(ii) n climat mantan (zona climatic a Romniei pentru perioada de iarn IV), terasele
circulabile cu dale pe ploturi-distanier, vor fi prevzute cu sistem de degivrare sub dale,
ntre ploturi (rezistene speciale alimentate cu energie electric de joas tensiune, termostate,
cu acionare automat).
b) acoperiuri teras i pri de cldiri cu pant general > 1,5% i < 8%;
c) alte pri sau elemente de construcie ce pot fi ncadrate funcionale ca acoperiuri terase, cu
pante >8% i < 20% pentru care se pun condiii sporite de fixare/lipire, pentru a preveni
alunecarea;
(2) Cerine de calitate, condiii tehnice i de performan specifice, ce trebuiesc avute n vedere:
Cerine de calitate
1

Condiii tehnice
2

aptitudine de exploatare

rezisten mecanic i stabilitate


capacitatea de rezisten i
stabilitate
durabilitate structural

securitatea la incendiu

proprietile
produselor
hidroizolante
privind
iniierea,
reacia
i
propagarea unui incendiu

Criterii de performan
3
sgeat limitat sub sarcin (se refer la
structura hidroizolan n raport cu suportul);
rezistena la pliere, la perforare static i
dinamica rezisten i alungire la rupere la
traciune, rezisten la deslipire i la forfecare
a mbinrilor, stabilite la temperaturi ridicate,
stabilitate dimensional.
aderena la suport (realizat prin lipire sau
lestare).
durata de garanie (durata de utilizare
estimat).
reacie la foc;
rezisten la foc;
performane la foc exterior i interior;
comportare la foc;
propagarea incendiului;
aciunea fiziologic.

16

2
siguran n utilizare
prevenirea alunecrii

siguran n exploatare

comportare
climatici

la

ageni

igiena apei i aerului,


sntate aplicatorilor i
utilizatorilor

igien, sntate i mediu

protecie mpotriva zgomotului

economia de energie i izolare


termic

izolare la zgomot aerian;


zgomot
emis
de
acoperi/nvelitoare
echiparea cu instalaii de
producere de energie
protecia termic

3
rezistena la perforare static i dinamic.
coeficientul de frecare n planul dat.
stabilitate dimensional la variaii de
temperatur;
rezisten la radiaii solare (dup caz);
rezisten la gelivitate (dup caz).
nu se admit emisii de substane toxice sau
insalubre n utilizare;
la execuie: adoptarea msurilor PSI i PSM ce
se impun (dup caz), n special n cazul
produselor toxice i/sau inflamabile.
dup necesitile funcionale, prevederea de
sisteme de atenuare a zgomotului.
prevederea modurilor de amplasare pe izolaie,
de utilaje, fr afectarea/ deteriorarea etaneitii
diminuarea ocului termic;
izolaie termic ranversat sau protecie grea a
hidroizolaiei

Art.35
Hidroizolaia elementelor sau prilor de cldiri mpotriva infiltraiilor datorate apelor fr presiune
hidrostatic, a umiditii naturale a mediului/solului, a apelor din stropire i/sau iroire.
(1) Obiect de referire:
a) elemente sau pri de cldire, hidroizolate mpotriva infiltraiilor, datorate apelor fr presiune
hidrostatic permanent (se va considera >0,2 m, coloana de ap/ 2 kPa), mpotriva umiditii
naturale a mediului, a apelor din stropire i/sau iroire, ocazionale, de regul, la pardoselile
camerelor supuse la umeziri, stropiri, splri sau iroiri (aflate n general ntr-un climat
constant), cu temperaturi pozitive; de exemplu: bi, buctrii);
b) elemente sau pri e cldire hidroizolate mpotriva infiltraiilor datorate apelor fr presiune
hidrostatic se va considera >1,0 m coloan ap/10 Kpa mpotriva umiditii naturale a
mediului/solurilor (permeabile, avnd coeficientul de permeabilitate k>1 cm/sec) permeabile i
a apelor din stropire/i sau iroire, intense, semipermanente, cu referire la pardoselile camerelor
i la soclurile cldirilor/prilor de cldire ce nu corespund unor subsoluri funcionale, cu
utilizare uman permanent;
c) socluri i fundaii izolate sau continue hidroizolante mpotriva fenomenului de migraie
capilar a apei (se va considera o presiune > 2,0 m coloan de ap/20 kPa).
d) de regul, acest tip de hidroizolaii se aplic pe suport rigid i sunt acoperite cu protecii sau
elemente grele, compacte.
(2) Cerine de calitate, condiii tehnice i criterii de performan specifice, ce trebuiesc avute n vedere:
Cerine de calitate
1

Condiii tehnice
2
aptitudine de exploatare

rezisten mecanic i
stabilitate
securitatea la incendiu

capacitatea de rezisten i
stabilitate
durabilitate structural

proprietile
produselor
hidroizolante privind iniierea,

Criterii de performan
3
rezistena la perforare static, rezisten la deslipire i
la forfecare a mbinrilor, stabilitate la temperaturi
ridicate, (dup caz), stabilitate dimensional.
aderen la suport (realizat prin lipire).
durata de utilizare estimat, garantat.
idem criteriile prezentate la Art.34 pct.(2), aplicabile
numai n timpul execuiei, hidroizolaia, n utilizare,

17

reacia i
incendiu
1

propagarea

unui

2
siguran n utilizare

siguran n exploatare
comportare la ageni climatici

igien, sntate i mediu

igiena apei i aerului, sntate


aplicatorilor i utilizatorilor

protecie
zgomotului

de regul, nu se impun condiii

mpotriva

economia de energie i
zolare termic

protecia termic

fiind cuprins,
incombustibile.

de

regul,

ntre

elemente

3
rezistena la perforare static.
stabilitate dimensional la variaii de temperatur
(dup caz);
rezisten la gelivitate (dup caz);
rezisten la ageni chimici i organici (dup caz);
nu se admit emisii de substane toxice sau insalubre
n utilizare;
la execuie: adoptarea msurilor PSI i PSM ce se
impun (dup caz), n special n cazul produselor toxice
i/sau inflamabile i a lucrului n spaii nchise,
limitate.

de regul, nu se impun criterii de performan;


dup caz, de regul, izolaia termic se aplic spre
exterior, peste hidroizolaie i poate avea rol i de
protecie mecanic

Art.36
Hidroizolarea elementelor sau prilor de cldiri contra apelor cu presiune hidrostatic.
(1)
Obiect de referire:
a) cldiri sau spaii/pri de cldire amplasate suprateran i/subteran, n care mmagazineaz
lichide sau materiale ude/umede, ce se hidroizoleaz contra exfiltraiilor cu presiune
hidrostatic;
b) cldiri sau spaii/pri de cldiri amplasate subteran, ce se hidroizoleaz contra infiltraiilor cu
presiune hidrostatic (ape freatice i de acumulare);
c) de regul, acest tip de hidroizolaii se aplic pe suport rigid i sunt cuprinse ntre pri/elemente
constructive, compacte, grele.
(2) Cerine de calitate, condiii tehnice i criterii de performan specifice, ce trebuiesc avute n vedere:
Cerine de calitate
1.

Condiii tehnice
2.
aptitudine de exploatare

rezistena
stabilitate

mecanic

i
capacitate de rezisten i
stabilitate
durabilitate structural

securitatea la incendiu

siguran n exploatare
igien, sntate i mediu

proprietile produselor
hidroizolante
privind
iniierea,
reacia
i
propagarea unui incendiu
sigurana n utilizare
comportare la ageni
climatici
igiena apei i aerului,
sntatea aplicatorilor i
utilizatorilor

Criterii de performan
3.
alungire la rupere la traciune i rezisten la alungire
la rupere raportate la deformaiile suportului;
rezistena la perforare static, rezisten la deslipire i
forfecare a mbinrilor, stabilitate la temperaturi
ridicate (dup caz), stabilitate dimensional.
aderena la suport (realizat de regul, prin lipire) pe
durata execuiei cldirii/prii de cldire.
durata de utilizare estimat, garantat (durata de
utilizare a cldirii) cu asigurarea etaneitii.
idem criteriile prezentate la Art. 35 pct.(2).

idem criteriile prezentate la Art.35 pct.(2)


idem criteriile prezentate la Art. 35 pct.(2);
produsele hidroizolante trebuie s fie nsoite de
avizul sanitar n cazul rezervoarelor de ap potabil.

18

protecie
zgomotului

2
mpotriva

economia de energie i
izolare termic

nu se impun condiii
protecia termic

de regul, nu se impun criterii de performan, doar


n cazul rezervoarelor exterioare sau a celor subterane
cnd se pun condiii de meninere a unei temperaturi
stabilite sau de a se elimina ngheul.

SECIUNEA a 2-a: Prezentarea membranelor hidroizolante bituminoase


Art.37
Membranele hidroizolante bituminoase constituie tipul cel mai utilizat n lume n realizarea structurilor
hidroizolante monostrat, bistrat sau multistrat, utilizabile la toate tipurile de hidroizolri i suporturi,
conform prevederilor productorului, fabricate n dou categorii principale:
(1) Membrane pe baz de bitum oxidat (bitum de extracie sau bitum natural oxidat prin insuflare de
aer la temperaturi ridicate) constituie categoria veche de membrane hidroizolante, n prezent cu
utilizare redus n C.E.; acestea, n general, prezint performane fizico-mecanice reduse. Lipirea
acestor membrane pe suport i ntre ele se face, de regul, cu mastic bituminos fierbinte. Nu se
admit structurile hidroizolante cu membrane pe baz de bitum oxidat la cldirile din categoriile de
importan A i B i nu sunt recomandate la cele din categoria de importan C. Structurile
hidroizolante cu membrane pe baz de bitum oxidat sunt, de regul, alctuite din trei straturi;
(2) Membrane pe baz de bitum aditivat reprezint categoria actual cea mai utilizat n C.E.; acestea
prezint performane fizico-mecanice foarte bune. Lipirea acestor membrane pe suport i ntre ele
se face prin sudur cu flacr, lipire la rece sau la cald cu masticuri sau prin autoaderen (pe
suport). Structurile hidroizolante cu membrane pe baz de bitum aditivat sunt alctuite din dou
straturi sau monostrat.
Aceast categorie de membrane se produce n dou sorturi principale dup tipul de aditivare a
bitumului uor oxidat cu polimeri:
a) bitum-plastomer, aditivat cu APP (polipropilen atactic); membranele produse au diverse
grosimi i au o bun comportare la aciunea solvenilor organici i la alungiri prelungite;
b) bitum-elastomer, aditivat SBS (copolimer-stiren-butadien-stiren); membranele produse au
diverse grosimi i au o bun comportare la alungiri prelungite i la temperaturi sczute;
c) un sort special l constituie membranele pe baz de bitum aditivat (cu APP sau SBS) simplu sau
dublu autoadezive prin depunerea pe o fa sau pe ambele fee a unui strat de bitum-polimeradeziv (polimeri i uleiuri plastifiate) i a unei folii neaderente de protecie care se ndeprteaz
la punerea n oper; ca variant la membranele autoadezive se produc benzi simpulu sau dublu
autoadezive (din membran bituminoas subire, folii polimerice sau metalice) utilizate la
etanri locale, de detaliu. Membranele autoadezive se utilizeaz ca prim strat hidroizolant
aplicat pe plci termoizolante sau ca barier contra vaporilor lipit de suport i peste care se
aplic plci termoizolante.
Art.38
Membranele hidroizolante bituminoase, de regul, sunt structural armate, cu unul, dou sau trei straturi
de armare impregnate i acoperite cu bitum sau, n foarte rare cazuri, sunt formate dintr-un strat de
bitum gros (laminat) sau depus pe un material suport.
(1) Straturi de armare sau suport din materiale organice:
a) carton celulozic: prezint caracteristici fizico-mecanice slabe (este putrescibil, are variaii
dimensionale apreciabile la variaii de temperatur i umiditate); se utilizeaz ca monostrat de
armare (suport) ce se bitumeaz pe ambele fee, de regul, cu bitum oxidat (carton bitumat); n
prezent nu se utilizeaz n structuri hidroizolante;
19

b) estur (pnz) din fire textile: n multe cazuri are un comportament aleatoriu i este
putrescibil, se utilizeaz ca monostrat de armare (suport) ce se bitumeaz pe ambele fee, de
regul, cu bitum oxidat (pnz bitumat); n prezent utilizarea acestei armturi este redus;
c) psl poliesteric (voal poliesteric): constituie un tip de armtur de utilizare curent avnd
certe caliti fizico-mecanice (impregnare bun, cu bitum, rezisten la perforare static i
alungire la traciune la rupere apreciabil); se utilizeaz ca strat de armare, ntr-un strat sau mai
multe straturi (de acelai fel sau n combinaii cu alte tipuri de armturi) sau ca strat suport a
membranelor bitumate aditive i poliesterice, precum i a structurilor hidroizolante cu mase
omogene, cu aplicare pelicular;
d) estur poliesteric: prezint caliti superioare pslei poliesterice (foarte bun rezisten la
perforare dinamic, stabilitate dimensional i la alungire la traciune la rupere); se utilizeaz ca
strat de armare sau ca strat suport a membranelor hidroizolante bituminoase i mai ales a celor
polimerice, precum i a structurilor hidroizolante cu mase omogene cu aplicare pelicular;
(2) Straturi de armare sau suport din materiale anorganice:
a) mpslitur (voal) din fibre de sticl: constituie un tip de armtur de utilizare curent, fiind
foarte stabil dimensional dar cu alungire la rupere redus i pliabilitate redus; se utilizeaz ca
strat de armare, ntr-un strat sau mai multe straturi (de acelai fel sau n combinaii cu alte tipuri
de armturi), sau ca strat suport a membranelor bituminoase (cu bitum oxidat sau aditivat) i
polimerice precum i a structurilor hidroizolante cu mase omogene cu aplicare pelicular;
b) estur din fire de sticl (cu urzeal i bttur din fire de sticl; nu se recomand bttur din
mee din fire sau fibre de sticl): constituie un tip de armtur frecvent utilizat avnd certe
caliti fizico-mecanice (rezistent la perforare static i dinamic, rezistent la traciune la
rupere); se utilizeaz ca strat de armare sau ca strat suport a membranelor bituminoase (cu
bitum oxidat sau aditivat) i polimerice, precum i a structurilor hidroizolante cu mase omogene
cu aplicare pelicular;
c) folii metalice, polimerice sau mixte (folii metalice i polimerice dublate): constituie, simple sau
ca strat suport al membranelor bituminoase sau polimerice (dublate la acestea), o puternic
barier contra vaporilor sau ca strat suport al benzilor autoadezive de etanare; foliile metalice
sunt, de regul, din plumb, aluminiu etirat, cupru sau oel inoxidabil;
d) reele metalice subiri (plase): constituie strat de armare pentru anumite membrane bituminoase
sau polimerice, speciale, sau ca strat de armare suplimentar n structuri hidroizolante la
etanarea mpotriva apelor cu presiune hidrostatic mare.
(3) Nu constituie strat de armare ranforsarile longitudinale din fire de sticl sau polimerice aplicate pe
armtura din psl poliesteric sau mpslitur din fibre de sticl.
Art.39
Membranele hidroizolante bituminoase sunt prevzute din fabricaie cu protecii antiaderente mpotriva
lipirii la ambalarea n suluri i cu autoprotecii mpotriva factorilor de mediu (pentru membranele
utilizate ca strat superior n structuri hidroizolante expuse direct factorilor de mediu).
(1) Proteciile antiaderente constau din filme/folii polimerice termofuzibile (numai la membranele ce se
lipesc prin sudur cu flacra), pulberi minerale i folii antiaderente sau hrtie siliconat pentru
membranele sau benzile autoadezive.
(2) Autoproteciile pot fi alctuite din:
a) granule sau paiete minerale: granule din nisip cuaros, pietri sau ceramic concasat, paiete din
ardezie sau mic etc.; acestea confer membranelor protecie eficient mpotriva aciunii
radiaiilor solare i a aciunilor mecanice (mrete considerabil rezistena la perforare static) i
totodat unele au i rol decorativ;
b) folii metalice: aluminiu (uzual 0,08 mm grosime 720 g/mp) i inox sau cupru (uzual 0,08 mm
grosime 390 g/mp); acestea se utilizeaz ca strat de protecie al hidroizolaiilor pentru
20

suprafeele verticale datorit calitilor reflectante (termoreflexie i reflexie a radiaiilor


ultraviolete);
c) folii polimerice: utilizate ca protecie mecanic (la perforare static); cele mai uzuale sunt foliile
poliesterice;
d) folii complexe, polimerice metalizate sau polimerice placate cu folii metalice: utilizate ca
protecie mecanic i contra radiaiilor solare;
e) compound bituminos special fabricat cu rezisten fa de factorii de mediu (radiaii solare, n
special UV); aceste compounduri bituminoase pot avea i nsuiri antivegetale (antirdcini) i
constituie materialul de baz n fabricarea membranelor cu bitum aditivat.

SECIUNEA a 3-a:
Prezentarea maselor omogene hidroizolante bituminoase, cu
aplicare pelicular Alctuirea structurilor hidroizolante conditii de proiectare i
execuie.
Art.40
(1) Produsele hidroizolante bituminoase din mase omogene cu aplicare pelicular constituie gama de
produse cu utilizri i aplicri variate (amorse, mase peliculare hidroizolante, mase adezive i mase
de etanare) n compoziii i structuri diverse, conform prevederilor productorului.
(2) Hidroizolaiile subterane cu produse bituminoase din mase omogene cu aplicare pelicular nu se
vor utiliza la cldiri din categoria de importan A i B dar pot fi prevzute la celelalte categorii dar
numai ca hidroizolaie subteran, a structurilor i fundaiilor cldirilor mpotriva apelor fr
presiune hidrostatic.
Art.41
Clasificarea produselor dup tipul bitumului:
(1) Bitumul oxidat reprezint materialul primar utilizat n realizarea membranelor cu bitum oxidat, n
lipirea acestora i ca material de baz la amorsarea suprafeelor. n lucrrile de hidroizolaii,
bitumul oxidat se utilizeaz n urmtoarea gam de produse:
a) amorsa: bitum oxidat topit, diluat n solveni organici compatibili (1/3 bitum i 2/3 solvent), se
aplic rece, pentru asigurarea aderenei hidroizolaiei la suport; este interzis utilizarea
motorinei ca solvent sau ca amors;
b) mastic fierbinte: bitum oxidat topit cu adaosuri minerale (maxim 30% pulberi sau fibre
minerale), se aplic fierbinte la lipirea i peliculizarea suplimentar de suprafa a membranelor
cu bitum oxidat;
c) mastic rece: bitum oxidat (topit) cu adaosuri minerale i diluat n diverse proporii cu solveni
organici, se aplic rece, n diferite vscoziti, la peliculizri de suprafa, ca mas de paclu sau
ca adeziv (au caliti mediocre);
d) emulsii i dispersii n ap: material fluid, cu aplicare la rece, utilizat ca amors sau la
peliculizri hidroizolante (n special pentru spaii nchise sau cu pericol de incendiu i explozie).
(2) Mastic bituminos aditivat cu elastomeri sau plastomeri, cu aplicare la rece sau la cald, cu diverse
vscoziti. Se utilizeaz la lucrri de hidroizolaii sub forma urmtoarelor produse:
a) amorse-masticuri diluate n solveni organici compatibili sau emulsii i dispresii de ap, cu
aplicare pelicular, la rece pentru asigurarea aderenei hidroizolaiei la suport i peliculizare
superficial;
b) mastic fierbinte de lipire a membranelor bituminoase aditivate (lipire continu sau discontinu a
membranelor pe suport i lipire continu a membranelor ntre ele);
c) mase omogene cu diferite vscoziti, utilizate ca adeziv, ca mas de etanare sau strat de
impermeabilizare, cu aplicare pelicular n unul sau mai multe straturi, simple sau armate,
aplicate pe suprafeele amorsate.
21

Art.42
(1) Clasificarea produselor dup modul de aplicare se face n funcie de vscozitate; acestea se pot
aplica n unul sau mai multe straturi, cu sau fr straturi de armare, astfel:
a)
b)
c)
d)
(2)

produse fluide: se aplic prin stropire, pulverizare, pensulare sau cu trafaletele;


produse semifluide: se aplic prin pensulare sau cu trafaletele;
produse semivscoase: se aplic cu racle sau cosoroaba;
produse vscoase: se aplic cu paclul.
Caracteristicile produselor hidroizolante bituminoase din mase omogene cu aplicare pelicular,
variaz funcie de consistena i domeniul de utilizare:
a)
masele fluide (amorse) trebuie s aib nivelul de fluiditate necesar ptrunderii n porii
elementului (suport) pe care sunt aplicate i s formeze o pelicul continu, aderent i uniform;
b)
masele semifluide, pn la cele vscoase trebuie s ndeplineasc urmtoarele condiii: s fie
aderente la suportul amorsat; s fie impermeabile la ap; s fie stabile la temperaturi ridicate; s fie
elastice la temperaturi sczute i ridicate (la temperaturi ridicate s nu curg); s fie compatibile
chimic cu elementele sau materialele cu care vin n contact i adezivii s corespund rolului (nivel
de adeziune/coeziune, stabilitate, elasticitate la temperaturi sczute i nalte, etc.).
Art.43
Hidroizolaiile bituminoase din mase omogene cu aplicare pelicular trebuiesc prevzute i puse n
oper n condiiile respectrii stricte a productorului de sistem, in structuri monostrat sau multistrat, cu
sau fr straturi de armare.

SECIUNEA a 4-a: Prezentarea membranelor hidroizolante polimerice


Art.44
Membranele hidroizolante sunt produse diverse din categoria polimerilor elastomeri sau plastomeri
(produi de polimerizare nalt a hidrocarburilor nesaturate). Procedeul de fabricare a membranelor
polimerice const n laminare, calandrare, extrudere sau procedee mixte. Membranele polimerice sunt
prezentate n variate compounduri, moduri de fabricare, structuri hidroizolante i moduri de aplicare,
utilizate la toate tipurile de hidroizolri i suporturi, n structuri monostrat, conform pervederilor
productorului.
Art.45
Materialele polimerice din care se produc membranele hidroizolante:
(1) Materialele plastice:
a) CSM sau PE-CS
Polietilen cloro-sulfonat
b) EEA
Etilen/etilacetat
Terpolimer etilen/etilacetat (declarat prin cuvinte n scris)
c) EBA
Etilen/butil acetat
d) ECB sau EBT
Etilen, copolimer, bitum
e) EVAC
Etilen/vinilacetat
f) FPO sau PO-F
Poliolefin flexibil
g) FPP sau PP-F
Polipropilen flexibil
h) PE
Polietilen
i) PE-C
Polietilen clorurat
j) PIB
Poliizobutilen
k) PP
Polipropilen
l) PVC
Policlorur de vinil

22

(2) Cauciucuri tip elastomeri:


a) BR
Cauciuc butadienic
b) CR
Cauciuc cloroprenic
c) CSM
Cauciuc polietilen cloro-sulfonil
d) EPDM
Terpolimer de etilen, propilen i o dien cu poriunea nesaturat
rezidual de dien n lanul lateral
e) IIR
Cauciuc isopren-isobuten (butil cauciuc)
f) NBR
Cauciuc acrilonitril-butadienic (nitril cauciuc)
(3) Cauciucuri termoplastice:
a) EA
Amestec elastomeric
b) MPR
Topitur de cauciuc procesabil
c) SEBS
Stiren etilen butilen stiren
d) TPE
Elastomeri termoplastici, nereticulai
e) TPE-X
Elastomeri termoplastici, reticulai
f) TPS sau TPS-SEBS
SEBScopolimeri
g) TPV
Cauciuc termoplastic vulcanizat
(4) Membrane compozite: membrane realizate prin laminare, calandrare sau extrudere, dublate cu foi
din recepturi diverse, cu sau fr armare, cu urmtoarele precizri:
a) stratul de armare poate fi inclus n masa membranei sau poate constitui suportul membranei;
b) stratul de armare poate avea rol de a conferi caliti fizico-mecanice superioare (membranei
nearmate) sau poate avea rol tehnologic de fabricare
c) stratul de armare, ca suport al membranei, poate avea i rol de difuzie a vaporilor;
d) difuzia vaporilor se poate realiza i prin amprentarea sau agrenarea feei inferioare a
membranei.
Art.46
Membranele polimerice pot fi autoprotejate (din fabricaie) fa de factorii de mediu (n special radiaii
UV i IR) prin dublare cu folii polimerice sau metalice, peliculizare de suprafa sau n mas prin
natura materialelor componente (diverse adaosuri; de exemplu: negru de fum), cu urmtoarele
precizri:
a) membranele polimerice fr autoprotecie trebuie protejate suplimentar prin lestare (pietri, dale)
sau prin includere ntre elemente de construcie (beton, zidrie, ape);
b) membranele polimerice (n special cele cu utilizare la hidroizolanii subterane) vor avea adaosuri
biocide n materialelor componente de baz care s-i confere rezisten la vegetale (rdcini),
mucegaiuri, bacterii, etc.;
c) unele membrane polimerice (speciale), prin natura materialelor componente, pot fi rezistente la
diveri ageni chimici.
Art.47
Membranele polimerice pot fi armate cu materiale tip reea (esturi rare cu acelai tip de urzeal i
bttur) din fire textile, sticl, poliesterice sau chiar metalice subiri sau dublate pe psl din fibre
poliesterice sau din sticl; nu sunt excluse nici un fel de alte combinaii de materiale.
Art.48
Membranele polimerice se pot aplica pe suport n diferite moduri:
a) flotant, simplu aezat (prelat), cu fixare mecanic pe contur i asigurarea n cmp prin lestare sau
cu fixare mecanic;
b) prin lipire continu sau discontinu cu adezivi specifici cu aplicare la rece sau cu mastic de bitum
cu aplicare la rece sau la cald (condiie de compatibilitate a membranei la adezivi sau la bitum);
c) prin lipire continu prin autoaderen;
23

d) n sistem mixt.
Art.49
Membranele polimerice se utileaz de regul ca hidroizolanii monostrat; unele produse se pot asocia n
structuri bistrat (caz n care straturile se lipesc continuu ntre ele cu adezivi specifici cu aplicare la rece,
prin autoaderen sau prin lipire cu bitum fierbinte) sau se pot asocia membrane polimerice cu
membrane bituminoase.
Art.50
Etanarea suprapunerilor (prin suprapunerea membranelor i/sau prin suprapunerea de benzi
acoperitoare joantei, din acelai material sau cu alte materiale compatibile), se poate realiza n diverse
moduri:
a) lipire prin dizolvarea superficial a suprafeelor de contact;
b) sudur prin topirea superficial a suprafeelor de contact cu jet de aer fierbinte;
c) sudur cu microunde de nalt frecven;
d) lipire cu adezivi specifici aplicai la rece sau la cald;
e) lipire prin autoaderen;
f) marginile se pot etana suplimentar prin cordon de sudur realizat cu electrod specific din material
polimeric sau cordon cu mastic de etanare specific (n cazul lipirii prin dizolvare superficial).
Art.51
Specificaii calitative generale:
a) membranele polimerice armate trebuie s prezinte o stabilitate dimensional la cald mai bun de
0,2% (valorile negative, contraciile, se relev n sens longitudinal iar cele pozitive, alungirile, n
sens transversal), prin expunere timp de 6 ore la + 800 C;
b) membranele polimerice trebuie definite i din punct de vedere al comportrii la mbtrnire
accelerat; acestea nu trebuie s sufere modificri mai mari de 10% a principalilor parametri dup
expunere la xenotest timp de 10.000 ore;
c) membranele polimerice se definesc ca domeniu de utilizare (din punct de vedere al recepturii) n
membrane cu utilizare suprateran (la acoperiuri) i subteran (membranele polimerice specifice
lucrrilor subterane conin substane biocide mpotriva mucegaiurilor, ciupercilor, bacteriilor, etc.).

SECIUNEA a 5-a:
Prezentarea maselor omogene hidroizolante polimerice, cu
aplicare pelicular Alctuirea structurilor hidroizolante; conditii de proiectare i
execuie
Art.52
(1) Produsele hidroizolante polimerice i mixte din mase omogene cu aplicare pelicular constituie o
gam larg de produse mai noi pe plan mondial, cu utilizri, moduri i condiii de aplicare foarte
variate, (n minim dou straturi, armate sau fr armare, aplicate pe suportul rigid, amorsat);
(2) Hidroizolaiile cu produse polimerice din mase omogene cu aplicare pelicular nu se vor utiliza la
cldiri din categoria de importan A i B, precum i n cldirile situate n climat montan;
(3) Hidroizolaiile cu produse polimerice din mase omogene cu aplicare pelicular se pot prevedea fr
restricii la bazine i rezervoare de stocare ape, vizitabile (care comport lucrri de ntreinere i
reparaii);
(4) n general, pentru hidroizolaiile din aceast categorie, se impune o studiere i analiz atent i
asigurarea condiiilor privind umiditatea i nivelul de fisurare/microfisurare a suportului rigid,
eventuala caroiere a suportului cu rosturi de lucru n cmp i pe contur (20 mp40 mp),
temperaturile de lucru, asigurarea corectei tehnologii de lucru (amestecuri/dozaje la masele
omogene bicomponente, asigurarea rosturilor), precum i asigurarea corespunztoare a sistemelor
de protecie (de exemplu asigurarea cmpurilor dalate cu rosturi);
24

(5) n general, varietatea tehnologiilor i condiiilor de aplicare impune folosirea de aplicatori foarte
bine calificai i atestai de firma productoare;
(6) Se menioneaz c parte din aceste produse necesit ntreinere cu intervenii de regenerare,
periodice, stabilite de productor.
Art.53
Hidroizolaiile cu produse polimerice i mixte (bitumpolimeri) din mase omogene cu aplicare
pelicular trebuiesc prevzute i puse n oper n condiiile respectrii stricte a prevederilor
productorului de sistem, n structuri monostrat sau multistrat, cu sau fr stucturi de amorsare.

SECIUNEA a 6-a:
bituminoase

Sistem de evaluare calitativ a membranelor hidroizolante

Art.54
Membranele hidroizolante bituminoase se caracterizeaz, conform standardelor europene i romneti
(SR EN), prin criterii i niveluri de performan. Membranele hidroizolante bituminoase trebuiesc
nsoite de fie (emise de productor i/sau de reprezentanii tehnici sau comerciali ai acestora), care s
cuprind caracteristicile fizico-mecanice i/sau simbolurile nivelurilor de performan privind minim
impermeabilitatea, rezistena la sarcin static, rezistena la impact, pliabilitatea la temperaturi sczute,
rezistena la rupere, rezistena la fluaj i performanele la foc exterior i reactie la foc.
(1) Impermeabilitatea (etaneitatea) I
Se determin conform SR EN 1928:2003, prin niveluri de presiune meninut timp de 24 ore, la
care membran, de grosime dat, este etan:
Niveluri de performan
I
I.1. (metoda A)
I.2. (metoda A sau B)
I.3. (metoda B)
I.4. (metoda B)
I.5. (metoda B)

Presiunea minim pentru care se


asigur etaneitatea
(kPa/m. coloan ap)
10/1,0
60/6,0
100/10,0
200/20,0
400/40,0

(2) Rezisten la sarcin static Ps


Se determin conform SR EN 12730:2003, prin niveluri de ncrcri statice, meninute timp de 24
ore, la care membrana, de grosime dat, este etans (metoda A cu suport rigid; metoda B cu suport
semielastic):
Niveluri de performan
Ps
Ps.1 (metoda A i B)
Ps.2 (metoda A i B)
Ps.3 (metoda A i B)
Ps.4 (metoda A i B)
Ps.5 (metoda A i B)

ncrcare minim la care se


asigur etaneitatea
(cap sferic 10mm kg)
5
10
15
20
25

(3) Rezistena la impact Pd


Se determin conform SR EN 12691:2006, prin niveluri de nlime de cdere a unui corp de 500 g,
la care membrana, de grosime dat, este etan (metoda A cu suport rigid metoda B cu suport
semielastic):

25

Niveluri de performan
Pd
Pd.1 (metoda A i B)
Pd.2 (metoda A i B)
Pd.3 (metoda A i B)
Pd.4 (metoda A i B)
Pd.5 (metoda A i B)

a)

ncrcare minim de cdere a corpului


de cdere, la care se asigur etaneitatea
(mm)
200
500
1000
1500
2000

se va indica nivelul de performan i metoda de determinare (A sau B; de exemplu: Pd 3


B);

b)

pentru hidroizolaiile aplicate pe suport rigid se vor putea lua n considerare nivelurile
determinate prin metoda A;
c)
pentru hidroizolaiile aplicate pe structura termoizolant se vor lua n considerare numai
nivelurile determinate prin metoda B.
(4) Pliabilitatea la temperaturi sczute F
Se determin conform SR EN 1109:2003, prin niveluri de temperaturi negative, la care membrana,
de grosime dat, nu prezint deteriorri, dup ndoirea pe dorn:
Niveluri de performan
F
F.1
F.2
F.3
F.4
F.5
F.6

Temperatura la care s-a


determinat flexibilitatea
(o C)
0
-6
- 12
- 18
- 24
- 30

(5) Rezistena la rupere la traciune R


Se determin conform SR EN 12311-1:2002, prin niveluri ale forei de traciune, la care membrana,
de grosimea dat, se rupe:
Niveluri de performan
R
R.1
R.2
R.3
R.4
R.5

Rezisten la rupere la traciune


Longitudinal (N/5 cm)
Transversal (N/5 cm)
< 150
< 100
> 150
> 100
> 250
> 200
> 350
> 300
> 450
> 400

(6) Alungirea la traciune (la rupere) A


Se determin conform SR EN 12311-1:2002, prin niveluri ale alungirii la care membran, de
grosime dat, se rupe:
Niveluri de performan
A
A.1
A.2
A.3
A.4
A.5
A.6
A.7

Alungire la rupere la traciune


Longitudinal (%)
Transversal (%)
<2
< 1,5
2
1,5
5
3,5
10
8
20
16
40
32
60
48

(7) Rezistena la fluaj T


26

Se determin conform SR EN 1110:2001, prin niveluri de temperatur la care pe membrane, de


grosime dat, apar deplasri > 2 mm ale masei de bitum:
Niveluri de performan
T
T.1
T.2
T.3
T.4

Temperatura la care
deplasrile bitumului < 2 mm
(o C)
+ 80
+ 100
+ 120
+ 140

(8) Performan la foc exterior i reacie la foc conform SR ENV 1187:2003, SR EN 13501-5+A1:2010
i SR EN ISO 11925-2:2002;
(9) Aderena membranelor hidroizolante bituminoase aplicate n total aderen pe suport rigid i ntre
ele prin sudur cu flacra, lipire cu mastic fierbinte sau cu mastic adeziv la rece va fi de minim
0,3N/mm2 (recomandabil minim 0,4N/mm2 pentru structurile hidroizolante nelestate).
Art.55
Membranele hidroizolante bituminoase i hidroizolaiile din mase omogene cu aplicare pelicular
comport i parametri auxiliari de evaluare ce pot fi avui n vedere:
a)
rezisten la dezlipire a mbinrilor; conform SR EN 12316-1:2001;
b)
rezistena la forfecare a mbinrilor; conform SR EN 12317-1:2001;
c)
stabilitate dimensional; conform SR EN 1107-1:2002;
d)
aderena granulelor minerale la suport; conform SR EN 12039;
e)
aderena la suport (lipirea membranelor pe suport i ntre ele) Fad n vederea prevenirii
efectelor suciiunii i presiunii vntului (N/m2):
(i)
fora minim de aderen la suport (prin lipire/sudur):
Fad 3 Pc
unde Pc este presiunea maxim, previzibil, luat n calcul a vntului (pozitiv sau negativ)
funcie de zona geoclimatic de situare i nivelul de expunere la vnt.
(ii)
fora minim de aderen la suport din lipire i lestare, se determin cu formula:
Fad = a x G + a x Pa
unde: G este presiunea de lestare pe m2 (lestare suplimentar + greutatea membranei
hidroizolante);
a este suprafaa efectiv de lipire (n puncte sau total) raportat la 1 m2;
Pa este fora de aderen n zonele de lipire efectiv, n N/m2;
a este suprafaa de referin lestata.
Art.56
Model orientativ de evaluare calitativ a membranelor hidroizolante bituminoase (la o grosime
nominal de 4 mm):
Calitatea
1. (foarte bun)
2. (bun)
3. (satisfctor)
4. (mediocru)

SECIUNEA a 7-a:
polimerice

Niveluri minime de clasificare


I.5; Ps.5; Pd.5; F.4/F.6; R.5; (A.5; dup caz); T.4; stabilitate dimensional 0,1%
I.4; Ps.4; Pd.4; F.4; R.4; (A.5; dup caz); T.3; stabilitate dimensional 0,1%
I.3; Ps.3; Pd.3; F.3; R.3; (A.4; dup caz); T.2; stabilitate dimensional 0,2%
I.2; Ps.2; Pd.2; F.2; R.3; A.2; T.1; stabilitate dimensional 0,2%

Sistem de evaluare calitativ a membranelor hidroizolante

Art.57
Membranele hidroizolante polimerice se caracterizeaz, conform standardelor europene i romneti
(SR EN), prin criterii i niveluri de performan. Membranele hidroizolante bituminoase trebuiesc
27

nsoite de fie (emise de productor i/sau de reprezentanii tehnici sau comerciali ai acestora), care s
cuprind caracteristicile fizico-mecanice i/sau simbolurile nivelurilor de performan privind minim
impermeabilitatea, rezistena la sarcin static, rezistena la impact, pliabilitatea la temperaturi sczute,
rezistena la rupere, rezistena la fluaj i performanele la foc exterior i reactie la foc.
(1) Impermeabilitatea (etaneitatea) I
Aceleai prevederi ca la Art. 54 (1), cu meniunea c determinrile se fac numai prin metoda B;
(2) Rezistena la sarcin static Ps
Aceleai prevederi ca la Art. 54 (2), cu meniunea c determinrile se fac numai prin metoda B;
(3) Rezistena la impact Pd
Aceleai prevederi ca la Art. 54 (3);
(4) Pliabilitatea la temperaturi sczute F
Se determin conform SR EN 495-5:2003, prin niveluri de temperaturi negative, la care membrana,
de grosime dat, nu prezint deteriorri dup ndoire pe dorn; nivelurile de performan sunt
conform cu cele indicate la Art. 54 (4);
(5) Rezisten la rupere la traciune R
Se determin conform SR EN 12311-2:2010, prin niveluri ale forei de traciune, la care membrana,
de grosime dat, se rupe (metoda A):
Niveluri de performan
R
R.1
R.2
R.3
R.4
R.5

Rezistena la rupere la traciune


Longitudinal (N/5 cm)
Transversal (N/5 cm)
< 300
< 200
> 300
> 200
> 400
> 300
>600
> 500
> 800
> 700

(6) Alungirea la traciune (la rupere) A


Se determin conform SREN 12311-2:2010, prin niveluri ale alungirii, la care membrana, de
grosime dat se rupe (metoda A):
Niveluri de performan A
A.1
A.2
A.3
A.4
A.5
A.6
A.7
A.8

Alungire la rupere la traciune


Longitudinal (%)
Transversal (%)
<5
< 3,5
5
3,5
10
8
20
16
50
40
100
80
200
160
500
400

(7) Performan la foc exterior i reacie la foc conform SR EN 1187: 2003, SR EN 13501-5+A 1 : 2010
i SR EN ISO 11925 2: 2002.
Art.58
Membranele hidroizolante polimerice comport i parametri auxiliari de evaluare ce trebuiesc avui n
vedere:
a) rezistent la deslipire a mbinrilor; conform SREN 12316-2:2001;
b) rezisten la forfecare a mbinrilor; conform SREN 12317-2:2001;
c) stabilitate dimensional; conform SREN 1107-1:2002;
d) expunere la bitum;
e) aderen la suport (n cazul membranelor lipite pe suport, conf.Art.55 c).
Art.59
28

Model orientativ de evaluare calitativ a membranelor hidroizolante polimerice (la o grosime nominal,
medie, de 1,5 mm):
Calitatea
1. (foarte bun)
2. (bun)
3. (satisfctor)
4. (mediocru)

Niveluri minime de clasificare


I.5; Ps.5; Pd 5; F4/F5; R5; (A.8; dup caz); stabilitate dimensional 0,3%
I.4; Ps.4; Pd.4; F.4; R.4; (A.7; dup caz); stabilitate dimensional 0,3%
I.3; Ps.3; Pd.3; F.3; R.3; (A.5; dup caz) stabilitate dimenional 0,5%
I.2; Ps.2; Pd.2; F.2; R.3; (A.4; dup caz) stabilitate dimensinal 1,0%

SECIUNEA a 8-a:
Sistem de evaluare calitativ a produselor hidroizolante cu
mase omogene cu aplicare pelicular, bituminoase sau polimerice
Art.60
Masele omogene cu aplicare pelicular, bituminoase i polimerice sau mixte sunt caracterizate prin
criterii i niveluri de performan de ctre productori/productori de sisteme, care indic structurile de
etanare simple, omogene sau n straturi armate precum i tehnologiile de aplicare.
Art.61
Criteriile de performan principale la care trebuie s fie caracterizate prin niveluri de performan, de
regul, se refer la straturile/structurile hidroizolante stabilite de productori, n funcie de utilizare.
Nivelurile de performan, n general, rspund modului de aplicare a maselor omogene cu aplicare
pelicular, numai pe suporturi rigide.
(1) Impermeabilitatea (etaneitatea) I;
(2) Rezistena la rupere la traciune R;
(3) Alungirea la traciune A;
(4) Aderena la suport i a straturilor ntre ele (dup caz);
(5) Performana la foc exterior i reacie la foc conform SR EN 1187:2003, SR EN 13501-5+A1:2010
i SR EN 11925-2:2002;
(6) Rezistena la sarcin static Ps;
(7) Rezistena la impact;
(8) Pliabilitatea la temperaturi sczute F;
(9) Stabilitate dimensional;
(10) Permeabilitatea la vapori
Art.62
Structurile hidroizolante din mase omogene, cu aplicare pelicular se n total aderen pe suport
continuu i rigid; n acest context sunt n acest context sunt prevzute criterii i niveluri de performan
raportate la funciunea hidroizolaiei.
(1) Hidroizolaii supraterane, supuse direct aciunilor factorilor de mediu (acoperiuri-terase):
a) impermeabilitatea I: asigurarea etaneitii la o presiune de minim 100 kPa (10,0 m coloan
ap);
b) rezistena la rupere la traciune R: > 250 N/ cm longitudinal i > 200 N/cm transversal;
c) alungire la traciune A : >10%, longitudinal i transversal;
d) aderena la suport: conform Art. 54.9);
e) performana la foc exterior i reacie la foc: conform reglementrilor;
f) rezistena la sarcin static Ps : minim Ps3 (metoda B), conform Art. 54; (2);
g) rezisten la impact Pd: minim Pd.3 (metoda A), conform Art. 54, (3);
h) pliabilitatea la temperaturi sczute F: s nu se deterioreze la pliere la + 6 o C n zona climatic
I i la 12o C n zona climatic II i III (conform zonare climatic a Romniei pentru perioada
de iarn C.107-2005);
i) stabilitate dimensional: 1%.
29

(2) Hidroizolaii subterane sau supraterane mpotriva apelor fr presiune hidrostatic:


a) impermeabilitate I: asigurarea etaneitii la o presiune de minim 10 kPa (1 m coloan de ap)
pentru referirea de la Art. 35; (1); a), hidroizolaii n spaii interioare, i minim 60 kPa (6 m
coloan de ap) pentru referirea de lsa Art. 35; (1); b);
b) rezistena la rupere la traciune R: > 250 N/cm longitudinal i > 200 N/cm transversal;
c) alungirea la traciunea A: > 10%, longitudinal i transversal;
d) aderena la suport: conform Art. 55; e);
e) performana la foc exterior i reacie la foc: conform reglementrilor;
f) rezistena la sarcin static Ps: minim Ps.3 (metoda B), conform Art. 54; (2);
g) rezistena la impact Pd: minim Pd.3 (metoda A), conform Art.54; (3);
h) pliabilitatea la temperaturi sczute F: pentru hidroizolaii interioare s nu se deterioreze la
pliere la 0o C pentru hidroizolaii exterioare s nu se deterioreze la 6o C;
i) stabilitate dimensional: 1%.
(3) Hidroizolaii supraterane sau subterane mpotriva apelor cu presiune hidrostatic:
a) impermeabilitate I: asigurarea etaneitii la o presiune de:
(i) minim 100 kPa (10,0 coloan ap) pentru presiuni exercitate de maxim 50 kPa;
(ii) minim 200 kPa (10 m coloan ap) pentru presiuni exercitat de maxim 100 kPa;
(iii)
minim 2,5 x presiunea maxim exercitat (> 100 kPa).
b) rezistena la rupere la traciune R:
(i)
> 300 N/5 cm longitudinal i 250 N/5 cm transversal, pentru presiune
exercitate de maxim 60 kPa (6 m coloan ap);
(ii)
> 400 N/5 cm longitudinal i 300 N/5 cm transversal, pentru presiuni
exercitate d emaxim 100 kPa (10 m coloan ap);
c) alungirea la traciune A: >10%, logitudinal i transversal;
d) aderena la suport: fora de aderen la suport Fad s fie minim de 2 x mai mare dect presiunea
exercitat;
e) performan la foc exterior i reacie la foc: conform reglementrilor;
f) rezisten la sarcin static Ps: minim Ps.4 (metoda A) pentru presiuni exercitate de maxim 60
kPa (6 m coloan apa) i Ps.4 (metoda B) pentru presiuni exercitate > kPa ( > 6 m coloan de
ap); conform Art. 54; (2);
g) rezistena la impact Pd: minim Pd 4(metoda A); conform Art. 54; (3);
h) pliabilitatea la temperaturi sczute F: s nu se deterioreze la 6o C;
i) stabilitate dimensional: 1%.

30

CAPITOLUL IV: Alctuirea structurilor hidroizolante


SECIUNEA 1: Alctuirea structurilor hidroizolante cu membrane hidroizolante
bituminoase i polimerice, la acoperiurile tip teras
Art.63
Structuri hidroizolante monostrat (membrane bitumate i polimerice)
(1)
Condiii privind poiectarea:
a) condiii generale privind domeniul de utilizare:
(i) hidroizolaiile monostrat nu se vor prevedea la cldiri din categoria de importan A i B;
(ii) hidroizolaiile monostrat nu se vor prevedea la cldiri situate n zona climatic IV;
(iii)
hidroizolaiile monostrat se vor aplica numai pe suport rigid; membranele bituminoase
se vor aplica numai n total aderen;
(iv)hidroizolaiile monostrat pot fi prevzute la terase cu pante 1,5%;
(v) hidroizolaiile monostrat pot fi prevzute numai la terase necirculabile i nu pot fi prevzute
n structuri cu termoizolaia ranversat;
(vi)suprafeele hidroizolate cu membrane polimerice, se recomand s fie plane, cu ct mai
puine strpungeri fa de planul nvelitorii (luminatoare, trape, domuri, instalaii, etc.);
(vii) pentru hidroizolaiile monostrat se vor utiliza numai membrane special produse pentru
acest mod de utilizare, respectndu-se strict prevederile productorului.
b) condiii privind alctuirea:
(i) se vor prevedea membrane bituminoase cu bitum aditivat cu grosimea nominal 4 mm sau
membrane polimerice cu grosimea 1,2 mm;
(ii) racordarea ntre planuri diferite (coame, scafe, dolii) va fi ntrit n lungul liniei de
intersecie cu un strat hidroizolant suplimentar cu limea desfurat de minim 50 cm peste
care se va aplica hidroizolaia monostrat bituminoas; n cazul membranelor polimerice care
nu comport lipire n total aderen, se recomand utilizarea unei membrane cu o grosime
mai mare fa de cea prevzut n cmpul curent.
c) condiii privind nivelurile minime de performan:
(i)
impermeabilitate (I): I.5;
(ii)
rezisten la sarcin static i la impact Ps/Pd:
membrane cu protecie suplimentar grea Ps/Pd3; membrane autoprotejate Ps4/Pd4 (metoda
B);
(iii)
comportament la temperatur ridicat (T): membrane
cu protecie suplimentar grea T.3; membrane cu autoprotecie T.4;
(iv)
rezistena la rupere la traciune (R): membrane lipite
n aderen total, semiaderen sau pozate flotant, cu sau fr fixare mecanic - R.5.;
(v)
alungirea la rupere la traciune (A): membrane lipite
n aderen total, semiaderen sau pozate flotant, cu sau fr fixare mecanic - A.3. pentru
aplicare pe suport rigid i A.5. pentru membrane bituminoase i polimerice cu aplicare pe
suport semirigid sau semielastic;
(vi)
flexibilitatea la temperaturi sczute (F): pentru
membranele lipite n aderen total, semiaderen sau pozate flotant F.3; pentru
membranele fixate mecanic F.4..
(2)
Condiii privind execuia:
a) condiii privind modul de aplicare:
(i) aplicarea membranelor pe suport cu pant sub 8% se recomand a se face n lungul liniei de
pant iar pe suport cu pant, peste 8% se recomand a se face perpendicular pe linia de
pant;
31

(ii) continuitatea etan a suprapunerilor se va realiza (prin lipire sau sudur continu) minim la
dimensiunea indicat de productor;
(iii)
linia suprapunerilor capetelor membranelor succesive nu va fi colinear ci decalat
cu minim 50 cm.
b) condiii privind nivelurile de performan minimale de etaneitate a suprapunerilor: nivelul de
asigurarea a etaneitii mbinrilor suprapunerilor va fi de minim 20 KPa (presiunea meninut
timp de 30 minute).
Art.64
Cmp curent-structuri hidroizolante multistrat
(1)
Condiii privin proiectarea:
a) condiii generale privind domeniul de utilizare:
(i) hidroizolaiile multistrat pot fi prevzute cu structuri cu membrane bituminoase, cu
structuri mixte cu membrane bituminoase i polimerice (compatibile la bitum) sau cu
structuri bistrat cu membrane polimerice (special concepute i aplicate, conform
prevederilor productorului);
(ii) hidroizolaiile cu membrane bituminoase cu bitum oxidat vor fi prevzute n minim trei
straturi;
(iii)
hidroizolaiile multistrat pot fi prevzute la cldiri situate n toate
zonele geoclimatice;
(iv) hidroizolaiile multistrat pot fi prevzute la terase i acoperiuri cu pante diverse, inclusiv
cele plate (pant 0);
(v) nu se vor prevedea terase cu pant (<0,5%) n zona climatic III i IV;
(vi) membranele componente ale structurilor multistrat se recomand s provin de la un
singur productor, n conformitate cu prevederile acestuia privind structurarea i modul de
aplicare.
b) Principii de amplasare a elementelor de construcie ce depesc sau sunt n planul nvelitorii
acoperiurilor terase, hidroizolate:
(i) realizarea i ntreinerea hidroizolaiei impune distane minimale ntre elementele ce
depesc planul nvelitorii (ntre suprafee verticale, atic, pazie, streain i domuri de
acces sau tehnologice, ventilaii, couri, luminatoare, etc.);
(ii) distanele l, L i d trebuie s fie conform urmtoarei schie exemplificate i tabel:

1.(m)
<0,40

d.(m)
0,25

32

0,40
>1,20

0,50
1,00

(iii) se va evita prevederea elementelor ce depesc planul nvelitorii cu lungimea


perpendicular pe linia de pant, n cmpul acoperiului, ci max. la distana d fa de
coam cu condiia ca l 2 d, conform urmtoarei schite exemplificative:

c) conceperea, dimensionarea i realizarea sistemelor/elementelor de preluare, colectare i


evacuare a apelor pluviale inclusiv a sistemelor de siguran (preaplin) se va face n
conformitate cu prevederile SR EN 12056-3:2002 Reele de evacuare gravitaional din
interiorul cldirilor. Partea 3: Sistem de evacuarea apelor meteorice, proiectare i calcule;
(i)
la terasele cu pant (<0,5%), se recomand ca numrul receptoarelor de evacuare a
apelor pluviale, inclusiv a garguielor de preaplin, sfie majorat de 1,5 x numrul necesar
rezultat din calculul conform reglementrilor specificce (cu meninerea seciunii) pentru
terasele cu pant (<0,5%);
(ii)
la terasele cu pant (<0,5%), se recomand ca distana (pe ambele direcii) dintre
receptoarele pluviale s nu depeasc 6 m.
d) condiii privind alctuirea:
(i) se vor prevedea structuri bistrat cu membrane bituminoase cu bitum aditivat cu grosimea
total de minim 5 mm, structuri multistrat cu membrane bituminoase cu bitum oxidat cu
grosimea total de minim 6 mm sau structuri bistrat mixte, cu membrane polimerice cu
grosimea de minim 0,8 mm i membrane bituminoase cu bitum aditivat cu grosimea de
minim 3 mm;
(ii) racordarea ntre planuri diferite va fi ntrit n lungul liniei de intersecie cu un strat
hidroizolant suplimentar cu limea de minim 0,25 m peste care se va aplica structura
hidroizolant multistrat; coamele i doliile se recomand s fie ntrite cu un strat
hidroizolant suplimentar cu limea desfurat de minim 50 cm;
(iii)
racordarea ntre planurile orizontal i vertical poate fi realizat sub un unghi de 45
prin utilizarea scafelor prefabricate (din membrane hidroizolante, lemn, etc.);
e) condiii privind nivelurile de performan (referitor la membranele componente structurii):
(i) impermeabilitate (I): pe suprafee plate sau cu pant sub 8% - I.3. iar pe suprafee cu pant
peste 8% - I.2.;
(ii) rezistene la sarcin static Ps i rezistene la impact Pd, conform tablou:

Suportul
hidroizolaiei

Teras necirculabil
cu protecie
autoprotecie
grea

pietonal cu
protecie grea

Teras utilitar
circulabil cu
pietonal (dale
protecie grea
pe ploturi)

grdin

33

rigid
semirigid
semielastic

(iii)

Ps1/Pd3 (A)
Ps1/Pd3 (B)
Ps2/Pd3 (B)

Ps2/Pd2 (A)
Ps2/Pd2 (B)

Ps3/Pd2 (A)
Ps3/Pd2 (B)

Ps4/Pd2 (A)
Ps4/Pd2 (B)

Ps3/Pd3 (A)
Ps3/Pd3 (B)

Ps3/Pd3 (A)
Ps3/Pd3 (B)

rezistena la fluaj T, conform tablou:


teras necirculabil cu autoprotecie
teras necirculabil cu protecie grea
teras circulabil cu dale pe ploturi
teras circulabil, carosabil sau grdin

T.2 sau T.1 peliculizat cu vopsea


termoreflectant (pentru pant <5%)
T.2
T.3
T.1

(iv)rezistena la rupere la traciune R: pentru pante <20% - R3; pentru zona climatic IV
R4; pentru suport semielastic R4;
(v) alungirea la rupere la traciune A: pentru suport rigid cu aplicare flotant sau semiflotant
i pentru suport semirigid cu aplicare n total aderen, flotant sau semiflotant A2;
pentru suport semielastic A3;
(vi)flexibilitatea la temperaturi sczute F: pentru suport rigid cu aplicare n total aderen
pentru zona climatic I i II F1; pentru suport semielastic F.4; pentru hidroizolaiile
aplicate n zona climatic IV se va majora la un nivel superior.
(2)
Condiii privind execuia:
a) condiii privind modul de aplicare:
(vii)
aplicarea membranei superioare pe suport cu pant sub 8% se
recomand a se face n lungul liniei de pant iar pe suport cu pant peste 8% se recomand a
se face perpendicular pe linia de pant; membrana superioar poate fi aplicat paralel cu
membrana inferioar dar decalat la 1/2 din lime sau poate fi aplicat perpendicular pe
membrana inferioar;
(viii)
pe suport (indirect) din tabl cutat, membrana se va aplica numai
perpendicular pe linia cutelor;
(ix)continuitatea etan a suprapunerilor se va realiza prin lipire sau sudur la dimensiunea
minim indicat de productor;
(x) linia suprapunerilor capetelor membranelor succesive nu va fi colinear ci va fi decalat cu
50 cm iar linia suprapunerilor capetelor membranelor stratului superior va fi decalat cu
minim 1 m fa de cea a stratului inferior.
b) condiii privind nivelurile de performan minime de etaneitate a suprapunerilor:
(i) nivelul de asigurare a etaneitii mbinrilor suprapunerilor va fi de 10 KPa la pante peste
5% i de 15 KPa la pante sub 5% (presiune meninut timp de minim 30 minute) precum i
la membranele aplicate pe suport semielastic.
Art.65
Structuri hidroizolante verticale (monostrat sau bistrat)
(1)
Condiii privind proiectarea:
a) condiii privind domeniul de utilizare:
(i) hidroizolaia vertical din membrane bituminoase se va prevedea n structuri ntrite, n
zonele cu ncrcri din zpad pe sol >2 kN/m 2 (n zonele ce presupun aglomerri de
zpad);
(ii) membranele ce compun hidroizolaia vertical vor fi de aceeai natur sau compatibile ntre
ele i cu cele ce compun structura hidroizolant curent, de cmp;
(iii)
suportul hidroizolaiei verticale se recomand s fie rigid sau elastic.
b) condiii privind alctuirea:
(i) se vor prevedea structuri monostrat sau bistrat cu membrane bituminoase cu bitum aditivat
sau cu membrane polimerice i minim structuri bistrat cu membrane bitumate cu bitum
oxidat;
34

(ii) la terasele circulabile, carosabile i tip grdin hidroizolaia vertical va fi minim bistrat (nu
se include stratul suplimentar de ntrire);
(iii)
racordul dintre suprafetele orizintale i verticale se va ntri; la structurile
hidroizolante cu membrane bituminoase, cu un strat suplimentar de intrire de minim 25 cm
lime desfurat (10+15 cm; 12,5+12,5 cm);
(iv)structura hidroizolant vertical va fi autoprotejat sau cu protecie suplimentar grea
(tencuieli armate sau elemente prefabricate);
(v) hidroizolaia vertical se va aplica n total aderen pe elementele suport;
(vi)hidroizolaia vertical se va aplica pe nlime minim de 30 cm n zonele submontane i pe
50 cm n zonele montane i depresionar-montane; se va prevede fixare mecanic continu a
prii superioare, terminale, a structurii hidroizolante; pentru nlimi mai mari de 60 cm se
vor prevede fixri mecanice pe o linie intermediar;
(vii)
hidroizolaia vertical se va racorda (ntoarce) pe capul aticelor sau se va fixa
mecanic la partea superioar.
c) condiii privind nivelurile minime de performan:
(i) impermeabilitate (I) - I.2.;
(ii) rezistena la sarcin static Ps: la structuri hidroizolante autoprotejate: Ps3.; la structuri
hidroizolante cu protecie suplimentar: Ps2.;
(iii)
comportamentul la temperatur ridicat (T): 100C; recomandabil T.3.(membranele
placate cu folie metalic T.2);
(iv)fora de rupere la traciune: R.4.;
(v) alungirea la rupere: A.2.;
(vi)flexibilitatea la temperaturi sczute: F.3.;
(vii) rezistena la sfiere; se va considera nivelul necesar pentru asigurarea stabilitii la
nivelul fixrilor mecanice.
(2) Condiii privind execuia
a) condiii privind modul de aplicare:
(i) intersecia ntre planul vertical i orizontal se va realiza n vinclu sau cu racord (scaf) la
45 (cu lungimea ipotenuzei de minim 5 cm); scafa poate fi realizat din ap din mortar
de ciment sau cu piese profilate, speciale (din membran bituminoas, lemn, etc.);
(ii) terminaia superioar a structurii hidroizolante se recomand a fi asigurat prin fixare
mecanic, prin introducere n li orizontal sau prin acoperire cu pies lcrimar;
(iii)
stratul suplimentar de ntrire va fi acoperit pe orizontal de hidroizolaia orizontal
monostrat sau va fi interpus ntre straturile hidroizolaiei orizontale multistrat. Stratul
hidroizolant vertical, exterior, se va suprapune peste ultimul strat (superior) hidroizolant
al structurii de cmp (orizontale);
(iv)hidroizolaia vertical va putea fi constituit din prelungirea hidroizolaiei orizontale
numai n sensul derulrii membranei hidroizolante; nu se admite racordarea pe vertical
n lungimea membranei hidroizolante.
b) condiii privind nivelurile de performan minimale de etaneitate a suprapunerilor: nivelul
de asigurare a etaneitii mbinrii suprapunerilor la structurile monostrat al mbinrilor
verticale va fi de 15 kPa i cel al mbinrilor cu suprafeele orizontale de 20 kPa iar la
structurile bistrat de 10 kPa, respectiv 15 kPa.

SECIUNEA a 2-a: Alctuirea structurilor hidroizolante mpotriva exfiltraiilor


Art.66
Condiii conceptuale:
(1) Condiii peproiectare privind domeniul de utilizare:
35

a)

hidroizolarea elementelor i prilor de cldire amplasate suprateran sau


subteran mpotriva exfiltraiilor se refer la etanarea spaiilor umede, cu splri i stropiri
ocazionale, periodice sau continue;
b)
hidroizolarea acestor spaii se poate concepe cu membrane hidroizolante sau
cu mase omogene cu aplicare pelicular i se concretizeaz prin hidroizolarea pardoselilor,
plintelor i dup necesiti a pereilor (suport rigid);
c)
protecia hidroizolaiilor se poate prevedea cu tencuieli, ape (aplicate
indirect, prin intercalarea unui strat de separare) sau placaje diverse.
Art.67
Condiii privind alctuirea, funcie de intensitatea solicitrii:
(1)
Solicitri moderate:
a)
se vor prevede hidroizolaii monostrat cu membrane bituminoase cu
bitum aditivat cu grosimea minim de 2,5 mm, cu membrane polimerice cu grosimea minim de
0,8 mm, structuri monostrat sau bistrat cu membrane bituminoase cu bitum oxidat cu grosimea
total de minim 3 mm;
b)
racordarea ntre planuri va fi ntrit, n lungul liniei de intersecie, prin
suprapunerea, de regul, a stratului vertical pe minim 10 cm pe stratul orizontal;
c)
hidroizolarea suprafeelor verticale (fiind mai puin solicitate) poate s nu
fie prevzut cu materiale hidroizolante ci din tencuieli i/sau finisaje impermeabile (vopsitorii,
placaje).
(2)
Solicitri intense:
a)
se vor prevedea hidroizolaii monostrat cu membrane bituminoase cu bitum
aditivat cu grosime minim de 3 mm sau cu membrane polimerice cu grosimea minim de 1,0
mm, recomandabil 1,2 mm sau cu structuri bistrat cu membrane bituminoase cu bitum oxidat cu
grosimea total, minim, de 4 mm;
b)
racordarea ntre planuri va fi ntrit, n lungul liniei de intersecie, cu un strat
hidroizolant suplimentar (membran) cu limea desfurat de minim 30 cm (minim 15 cm pe
vertical);
c)
hidroizolaia suprafeelor verticale (fiind mai puin solicitat) poate fi prevzut
conform prevederilor de la pct.(1) a) (suprafee orizontale).
Art.68
Condiii privind nivelurile minime de performan funcie de intensitatea solicitrii
(1)
Solicitri moderate:
a) impermeabilitate (I) - I.2.;
b) rezisten la sarcin static Ps i rezisten la impact Pd:
(i)
Ps2/Pd2 pentru suprafee verticale;
(ii)
Ps3/Pd3 pentru suprafee orizontale.
c) comportament la temperatur ridicat (T): T.2.
(2)
Solicitri intense:
a) impermeabilitate (I): I.3.;
b) rezisten la sarcin static Ps i rezisten la impact Pd:
(i) Ps3/Pd3 pentru suprafee verticale;
(ii) Ps4/Pd4. pentru suprafee orizontale.
Art.69
Condiii privind nivelurile minime de performan ale materialelor hidroizolante
a)
fora de rupere la traciune:
(iii)
R.2. pentru suprafee orizonatele;
(iv)R.3. pentru suprafee verticale.
36

b)
alungirea la rupere: - A.2.;
c)
flexibilitatea la temperaturi sczute: - F.1.
Art.70
Condiii privind execuia
(1) Condiii privind modul de aplicare
a) intersecia dintre planuri se recomand a se realiza n vinclu;
b) hidroizolaia vertical cu nlimea mai mare de 50 cm necesit fixare mecanic a marginii
superioare;
c) stratul suplimentar de ntrire i hidroizolaia vertical vor fi suprapuse cte minim 10 cm peste
hidroizolaia orizontal n cazul structurilor monostrat.
(2) Condiii privind nivelurile de performan minimale de etaneitate a suprapunerilor: nivelul de
asigurare a etaneitii mbinrilor (J) va fi de 20 KPa pe suprafeele orizontale i 15 KPa pe
suprafeele verticale.

SECIUNEA a 3-a: Alctuirea structurilor hidroizolante la acoperiurile tip teras i la


elementele de construcie mpotriva exfiltraiilor i/sau infiltraiilor cu mase omogene cu
aplicare pelicular
Art.71
Conditii privind proiectarea
(1) Masele omogene cu aplicare pelicular, bituminoase i, n special, polimerice trebuiesc prevzute n
condiiile stricte enunate de productor, privind:
a) domeniul de utilizare;
b) condiiile privind suportul pe care se aplic din punct de vedere al alctuirii, nivel de
fisurare/microfisurare, suprafee maxime ale cmpurilor caroiate prin rosturi de turnare,
nivelul rugozitii, umiditate maxim admis, etc.;
c) condiiile de aplicare (temperaturi, condiii meteorologice, numr de straturi, sistem de
armare, etc.);
d) moduri de protecie/acoperire i de ntlnire al interseciior dintre suprafee.
(2) Masele omogene cu aplicare pelicular, bituminoase, se pot prevedea la impermeabilizarea
suprafeelor mpotriva umiditii naturale a mediului i mpotriva apelor fr presiune hidrostatic
(exceptndu-se amorsele bituminoase), ntr-unul sau mai multe straturi ca sau fr strat/straturi de
armare (de exemplu: logii, copertine, socluri de fundaii sau suprafete verticale ale substraturilor);
(3) Masele omogene cu aplicare pelicular, polimerice, se pot prevedea la impermeabilizarea
suprafeelor mpotriva umiditii naturale a mediului i mpotriva apelor fr presiune hidrostatic i a
apelor cu presiune hidrostatic (bazine, rezervoare), de regul, in minim dou straturi, cu sau fr
strat/straturi de armare;
Art.72
Condiiile privind nivelurile minime de performan sunt prezentate la Art.62
Art.73
Conditii privind execuia:
(1) Respectarea cu strictee a prevederilor productorului privind:
a) condiiile privind suportul i condiiile meteorologice de lucru;
b) condiiile de utilizare a produselor n special a amestecurilor produselor bicomponente;
c) modul de aplicare a produselor de etanare i a straturilor de armare;
d) modurile de tratare a rosturilor i a intersectiilor dintre planuri diferite;
e) respecatrea tipurilor de aplicare a produselor pe straturi;
37

(2) Respectarea soluiilor i procedeelor de aplicare a straturilor/elementelor de finisaj i protectie

SECIUNEA a 4-a: Alctuirea structurilor hidroizolante a elementelor i prilor de


cldire amplasate subteran (socluri, fundaii, subsoluri) mpotriva infiltraiilor i/sau
exfiltraiilor
Art.74
Tipuri de prezen a apei pentru care este necesar hidroizolarea elementelor i prilor de cldire
amplasate subteran:
(1) Ape fr presiune hidrostatic:
a) umiditatea natural a terenului: provine din apele de precipitaie care nu stagneaz n sol i care
nu exercit o presiune hidrostatic (terenuri permeabile avnd k>0,01 m/s);
b) apa de scurgere: este apa n micare, sub efectul gravitaiei, n drum spre pnza freatic (terenuri
permeabile avnd k>0,01 m/s), care nu exercit presiune hidrostatic sau exercit o presiune
nesemnificativ, temporar.
(2) Ape cu presiune hidrostatic:
a) ape de infiltraie:
(i) apa de acumulare: este apa de scurgere care se acumuleaz prin ntlnirea straturilor greu
permeabile i exercit o presiune hidrostatic;
(ii)
apa de stratificaie: este apa de scurgere care ptrunde n straturi greu
permeabile strbtute de straturi permeabile i prin care se acumuleaz i exercit o presiune
hidrostatic;
(iii)
apa freatic: este apa care formeaz un strat compact ntre granulele de sol
i exercit o presiune hidrostatic.
b) ape de exfiltraie: apa de stocare: este apa coninut n bazine sau rezervoare;
c) aciuni combinate; infiltraie i exfiltraie.
Art.75
Situaii de prezen a apelor cu presiune hidrostatic pentru care este necesar hidroizolarea subteran a
construciilor

(2)

Dou construcii alturate, fundate la adncimi diferite, una fiind deasupra


i cealalt sub nivelul pnzei freatice. Dac construcia fundat sub nivelul pnzei freatice se afl n
amonte fa de sensul de scurgere al apei, construcia fundat peste nivelul pnzei freatice nu
necesit hidroizolaie iar dac se afl n aval se va hidroizola deoarece se ridic nivelul pnzei
freatice. Hidroizolaiile vor fi prevzute mpotriva apelor cu presiune hidrostatic. Construciile
aflate deasupra nivelului maxim al pnzei freatice se vor hidroizola mpotriva apelor fr presiune
hidrostatic.

38

(3)

Cazuri de construcii subterane ce se hidroizoleaz.

a)

construcia se afl n zona de scurgere natural a


apelor de infiltraie prin stratul permeabil (nisip)
aflat ntre dou straturi puin permeabile (argil)

b) construcia se afl n zona de scurgere natural a


apelor de infiltraie prin stratul permeabil (nisip)
situat sub stratul de pmnt vegetal, permeabil

c)

construcia se afl ntr-un teren puin permeabil iar


umplutura spturii este permeabil, ceea ce
conduce la acumulri de ape ce exercit presiune
hidrostatic

d) construcia se afl ntr-un teren puin permeabil dar


care are fracturi de teren permeabil ce converg spre
construcie i zona de umplutur a spturii

39

Art.76
Condiii generale privind domeniul de utilizare:
(1)
Hidroizolaiile se vor prevedea n urmtoarele
situaii:
a)
n cazul terenurilor n care nu exist pericol de infiltrare cu produse petroliere sau a
altor soluii care pot afecta caracteristicile calitative ale materialelor hidroizolante;
b)
n cazul cnd sunt avantajoase tehnic sau economic dect alte procedee ca: ridicarea
nivelului inferior al construciei, utilizarea de betoane sau mortare impermeabile,
impermeabilizarea terenului, prevederea de sisteme drenante, etc.
(2)
Proiectarea construciilor subterane se va face
astfel nct s se asigure posibilitatea executrii hidroizolaiei inndu-se seama de urmtoarele:
a)
forma construciei n plan i n seciune vor
fi ct mai simple pentru asigurarea unei manopere uoare i sigure;
b)
construcia se va amplasa de regul la o
distan de minim 1,20 m fa de alte construcii sau elemente de construcie existente sau n
curs de proiectare-execuie, pentru a avea spaiul necesar execuiei hidroizolaiei; n caz contrar:
se va prevedea un perete suport al hidroizolaiei distanat i separat fa de construcia existent
printr-un strat de desolidarizare i alunecare (plci deeuri cauciuc, plci polistiren expandat,
plci sau foi din materiale polimerice, etc.) sau se va retrage partea subteran a construciei la
distan de minim 1,20 m iar partea suprateran va iei n consol la limita necesar;
c)
la baza spturii, perimetral construciei,
vor fi prevzute rigole i puuri pentru dirijarea, colectarea i evacuarea apelor din precipitaii;
suplimentar, dac este cazul, se poate prevedea un sistem permanent de epuisment pentru
coborrea pnzei freatice la minim 30 cm sub nivelul betonului de egalizare, pentru a se asigura
un suport uscat pentru executarea hidroizolaiei (orizontale);
d)
n cazul hidroizolaiei n sistem cuv
exterioar betonul de egalizare de sub radierul construciei (subradier) trebuie prevzut cu o
supralrgire de minim 30 cm pe tot conturul radierului (cu ngroare i armare suplimentar
perimetral pentru a se mpiedica fisurarea) pentru crearea spaiului necesar de racordare a
hidroizolaiei verticale;
e)
n cazul radierelor situate la cote diferite,
subradierul ca suport al hidroizolaiei va fi racordat la 45 cu o diferen de nivel de maxim 1 m,
ntr-o singur treapt, sau n trepte multiple pentru diferene de nivel mai mari;
f)
elementele de strpungere vor fi nglobate
i fixate n suportul hidroizolaiei i la faa acesteia.
(3)
n cazul cnd la nivelul hidroizolaiei presiunea
2
depete 5 daN/cm , temperatura este mai mare de 40C, exist vibraii sau eforturi tangeniale,
etanarea se va realiza cu membrane hidroizolante bituminoase cu bitum aditivat sau polimerice;
(4)
La alegerea structurii hidroizolante se va ine
seama de nivelul de etanare admisibil concretizat prin starea feei interioare a pereilor sau
pardoselii:
a)
uscat nu se admit pete izolate de umezeal; constituie condiia curent de
exigen corespunztoare prevederilor prezentului normativ;
b)
umed - se admit poriuni izolate de umezeal pe suprafee de maxim 20%, fr
apariia stagnrilor sau picturilor de ap; nu se vor admite la spaiile cu utilizare uman sau
40

(5)

(6)
(7)

(8)

animal ci eventual numai la spaii tehnice n care nu exist activitate uman permanent sau
temporar;
c)
la construciile ce deservesc sau conin instalaii electrice i/sau electronice
hidroizolatia va fi ntrit cu minim un strat fa de prevederile prezentului normativ.
Categoriile de fisurare previzibile a construciei
dup valoarea limit de calcul a deschiderii fisurilor (criterii ce implic nivelul de rezisten la
alungire la rupere a materialelor hidroizolante preconizate):
a) cu deschiderea fisurilor pn la 0,1 mm;
b) cu deschiderea fisurilor pn la 0,2 mm;
c) cu deschiderea fisurilor de la 0,2 la 0,5 mm.
Hidroizolaia pereilor subsolurilor sau a cuvelor se
aplic, de regul, pe structura de rezisten (din beton armat sau zidrie);
Execuia se recomand a se efectua dinspre
exteriorul construciei, n spaiul rezultat din sptura (sistem cuv exterioar); n cazul n care nu
se poate asigura hidroizolarea pe exterior se poate adopta sistemul de execuie a hidroizolaiei din
interior (cuv interioar) pe peretele de protecie cu rol de suport;
Hidroizolaiile subterane se aplic n aderen
total pe ntreaga suprafa (pe suport i ntre membrane); n cazul n care elementul suport
orizontal este umed (nu se poate obine totala aderen) se poate prevedea un prim strat pozat
flotant, constituind astfel un suport uscat de aderen a membranelor hidroizolante ce compun
structura.

Art.77
Condiii privind hidroizolarea mpotriva apelor fr presiune hidrostatic i impotriva fenomenului de
capilaritate; se refer n general la hidroizolarea fundaiilor i soclurilor:
(1)
Condiii generale privind alctuirea:
a)
hidroizolaia orizontal va fi de regul monostrat i se va
realiza cu membrane hidroizolante bituminoase sau polimerice, la nivelul dintre fundaie i
soclu sau zidrie, cu sau fr racordare la hidroizolaia vertical (a soclului sau fundaiei);
b)
hidroizolarea orizontal a elementelor de fundare poate fi
prevzut i la nivelul tlpii fundaiei pe betonul slab armat de egalizare de minim 10 cm
grosime; recomandabil, de fiecare parte, se va asigura o lime util pentru a se putea face
racordarea la suprafeele verticale ale fundaiei sau soclului i pereilor pe ambele fee (exterior
i interior);
c)
hidroizolaia vertical va fi aplicat pe un suport din
tencuial cu mortar de ciment fr adaos de var, din dricuit;
d)
hidroizolaia vertical, exterioar, a fundaiilor, soclurilor i
pereilor subterani va fi ridicat peste cota finit a trotuarului cu minim 30 cm, n cazurile
amplasrii construciilor n zone montane i submontane, n care se prevd aglomerri de
zpad i n cazul stropirilor frecvente i intense (construcii cu acoperiuri cu scurgere la
pictur, cu streain ngust, etc.); n cazul zonelor de es cu stropiri moderate hidroizolaia se
poate ridica pn la cota trotuarului;
e)
hidroizolaia vertical poate fi alctuit dintr-o membran
hidroizolant bituminoas sau polimeric lipit continuu pe suport, fixat mecanic la partea
superioar sau din minim dou straturi din mase omogene cu aplicare pelicular eventual
armate, protejate subteran cu plci, panouri sau foi semirigide (simple, amprentate sau celulare),
zidrie sau ecran de argil compactat n straturi succesive i suprateran cu tencuieli armate din
mortar de ciment fr adaos de var sau zidrie.
41

Art.78
Condiii privind nivelurile minime de performan pentru hidroizolaia orizontal mpotriva
fenomenului de capilaritate:
a)
impermeabilitatea (I): trebuie s corespund la presiunea de calcul a elementelor
de construcie exercitat pe suprafaa materialului hidroizolant: recomandabil minim I.3;
b)
rezistena la sarcin static Ps i rezisten la impact Pd: Ps3/Pd3;
c)
comportament la temperatur ridicat (T): T.2.;
d)
pentru construcii parter, din categoria de importan C i D, hidroizolaia
orizontal mpotriva fenomenului de capilaritate poate fi realizat cu mase omogene cu aplicare
pelicular, n minim dou straturi, recomandabil cu strat de armare sau cu o membran
hidroizolant; nivelurile de performan pot fi I.2. i Ps3/Pd3.;
e)
rezistena la compresiune (strivire) a materialului hidroizolant - s nu-i schimbe
aparent proprietile fizice la o presiune de 5 daN/cm 2 (s permit o tasare stabil de maxim 15% cu
alungire lateral corespunztoare); (membranele hidroizolante bituminoase cu bitum aditivat, cu
simpla armare, de 4 mm grosime pot asigura impermeabilitatea la presiuni peste 5 daN/cm2).
Art.79
Hidroizolaia orizontal mpotriva apelor fr presiune hidrostatic (la subsoluri):
a)
impermeabilitate (I) - I.2.;
b)
rezistena la sarcin static Ps i rezisten la impact Pd Ps3/Pd3;
c)
comportament la temperatur ridicat (T) - T.2.
Art.80
Hidroizolaia vertical mpotriva apelor fr presiune hidrostatic:
a)
impermeabilitate (I) - I.2.;
b)
rezistena la sarcin static Ps i rezisten la impact Pd Ps3/Pd3;
c)
comportament la temperatur ridicat (T) - T.2.
Art.81
Hidroizolarea mpotriva apelor cu presiune hidrostatic se poate concepe, funcie de sensul de acionare
a presiunii corelat cu sistemul constructiv, n unul din urmtoarele sisteme:
(1) Sistemul cuv interioar (cuv n cuv):
a) sistemul poate fi adoptat n principal mpotriva exfiltraiilor; structura suport (cea exterioar) va
fi de rezisten cu radier din beton armat i perei din beton armat sau zidrie de crmid
(armat cu smburi i centuri din beton armat), pe aceasta se aplic hidroizolaia i protecia
interioar (cuv interioar); n cazul pereilor de sprijin (de tip perete mulat, piloii secani, etc.)
sunt necesare lucrri de asigurare a unei suprafee plane, aderente;
b) sistemul se poate adopta i n urmtoarele cazuri:
(i)
mpotriva infiltraiilor sau aciunilor combinate ale apei (din interior i din
exterior);
(ii)
cnd nu se poate adopta sistemul cuv exterioar din motive constructive
sau din imposibilitatea asigurrii spaiului necesar de lucru pe exterior;
(iii)
cnd construcia necesit rosturi de dilatare sau tasare (astfel se poate
asigura continuitatea i calitatea optim a hidroizolaiei n zona rosturilor).
c) sistemul prezint urmtoarele avantaje:
(i)
sigurana calitii execuiei hidroizolaiei (asigurarea etaneitii) n zonele
de racord dintre suprafeele orizontale i cele verticale precum i la rosturi;
(ii)
posibilitatea realizrii construciei lng alte construcii existente;
(iii)
posibilitatea verificrii, etaneitii (la exfiltraii) dup realizarea
hidroizolaiei prin proba cu apa, n cazul bazinelor supraterane.
42

d) sistemul prezint urmtoarele dezavantaje:


(i)
posibilitatea degradrii hidroizolaiei la execuia structurii cuvei interioare
(la montarea armturilor i la turanarea betonului);
(ii)
imposibilitatea verificrii etaneitii (la exfiltraii) n cazul construciilor
subterane.
(2) Sistemul cuv exterioar:
a) sistemul poate fi adoptat n principal, mpotriva infiltraiilor; structura suport orizontal va fi
subradierul iar cea vertical va fi peretele de rezisten (diafragm), pe acestea se aplic
hidroizolaia i protecia interioar i cea exterioar;
b) sistemul se poate adopta i mpotriva exfiltraiilor sau aciunilor combinate ale apei (din interior
i din exterior), cu condiia ca protecia vertical, exterioar s ndeplineasc cerinele de
rezisten i stabilitate ce se impun;
c) sitemul prezint avantajul combinrii cu sistemul cuv interioar n cazul unor situaii i
condiii diferite de lucru (vecinti, zone cu rosturi, canale, diferene de cote ale planurilor,
etc.);
d) sistemul prezint urmtoarele dezavantaje: necesit spaiu de lucru perimetral, exterior
construciei, fragmenteaz lucrarea de etaneitate n faze prin intercalarea lucrrilor de
construcie aferente sistemului i necesit o manoper de nalt calitate la racordul dintre
suprafeele orizontale i cele verticale.
(3) este o combinare a sistemului cuv interioar cu cel cuv exterioar; acest sistem implic
dificulti n execuie, ce conduc la o calitate necontrolabil, fapt pentru care nu este
recomandat.
Art.82
Condiii generale privind alctuirea hidroizolaiei mpotriva apelor cu presiune hidrostatic
(1)
Hidroizolaia se va aplica pe suport rigid i plan, rectificat;
(2)
Hidroizolaia vertical, aplicat pe nlimi mari, se va executa pe
tronsoane de maxim 2 m nlime, cu decalarea ntre ele a suprapunerilor (s nu existe colinearitate
a suprapunerilor); n condiiile n care se estimeaz pericol de alunecare a membranelor
hidroizolante, se va executa fixarea mecanic a prii superioare;
(3)
Pentru nlimi ale coloanei de ap mai mari de 2 m se recomand
utilizarea hidroizolaiei verticale multistrat;
(4)
Racordurile dintre planuri diferite vor fi asigurate suplimentar prin
aplicarea unui strat hidroizolant de ntrire de 50 cm lime desfurat (25 cm + 25 cm);
(5)
Elementele de strpungere i rosturile vor fi atent executate conform
detaliilor prevzute de proiectant, respectndu-se cu strictee condiiile impuse dimensionrii i
calitii pieselor de etanare.
Art.83
Condiii privind nivelurile minime de performan. Nivelurile de performan se vor calcula funcie de
solicitrile la care este supus hidroizolaia, privind nivelul maxim al presiunii hidrostatice i nivelul
presiunii exercitate de elementele de construcie, recomandabil conform urmtoarelor date:
(1)
Impermeabilitatea (I) nivel minim:I.3.; nivel calculat corespunztor
presiunii hidrostatice maxime multiplicat cu un coeficient de minim:
(i) 1,2 x pentru presiuni maxime de 10 KPa;
(ii) 1,5 x pentru presiuni maxime de 50 KPa;
(iii)
1,8 x pentru presiuni maxime de 80 KPa;
(iv)2,0 x pentru presiuni maxime de 100 KPa.

43

(2)

Rezistena la sarcin static Ps >1,5 presiunea exercitat de


elementele i rezistena la impact Pd minim Pd3;
(3)
comportament la temperatura ridicat (T): n general nu se pun condiii.

CAPITOLUL V:
SECIUNEA 1:

Condiii privind alctuirea i aplicarea structurilor termohidroizolante


Condiii privind suportul structurilor hidroizolante

Art.84
Condiii privind suportul rigid:
(1) Condiii privind planeitatea suportului sunt enuntate la Art.22 (pct.4;5;6;7 i8);
(2) Umiditile maxime ale suportului, enunate la Art. 22 pct.(3), se consider c sunt ideale pentru
aplicare direct a straturilor termihidroizolante; din acest motiv de regul, este necesar
impunerea ntre suport i termoizolaie a straturilor barier contra vaporilor, cu sau fr strat de
difuzie, n urmtoarele conditii:
a) aplicarea barierei vaporilor n total aderen sau semiaderen pe suport amorsat n cazurile
in care suportul poate avea umiditi mai mari dect cele menionate la Art.22 pct(3), cu
condiia nedepirii mediei umiditii relative de 60 % a aerului iflat n sapiile interioare
(sub elementul suport termohidroizolant) i a asigurrii unei ventilaii normale a spaiilor
interioare;
b) n cazurile n care conditiile enunate la pct. a) sunt la limit i/sau exist posibilitatea
depirii condiiilor, bariera contra vaporilor se aplic, pe suport, n semiaderen iar spaiul
de sub acesta se va pune n contact cu atmosfera (prin deflectoare);
c) n cazurile n care suportul este ud i/sau umiditatea relativ medie a aerului aflat n spaiile
interioare (sub elementul suport termoizolat) este peste 75% i/sau sunt temperatri ridicate i
degajri importante de vapori (n conditiile in care nu se realizeaz o climatizare i ventilare,
corespunztoare), se va prevedea strat de difuzie (pus n contact cu atmosfera prin
deflectoare) i barier contra vaporilor eficient de condiiile higrotermice.
Art.85
Condiii privind suportul din tabl cutat:
(1) Panourile din tabl cutat vor avea declarate de ctre productor i implicit de ctre furnizor, pe
tipuri, caracteristicile definitorii:
a) caracteristici geometrice: grosime tabl, dimensiuni cute;
44

(2)
(3)
(4)
(5)

b) caracteristici fizico-mecanice:
(i) tabelele cu indicarea distanei dintre reazeme (pentru dou, trei sau patru reazeme)
funcie de ncrcrile uniform distribuite date, raportate la grosimile de fabricaie a
tablei, pentru o sgeat dat;
(ii) momentul de inerie geometric I (cm4), pentru calculul sgetii;
(iii)
modulul de rezisten W (cm3), pentrun calculul eforturilor capabile;
Panourile din tabl cutat vor avea grosimea tablei 0,75 mm, nlimea cutei >70 mm i 120
mm; limea cutei superioare va fi de minim 1,5 ori mai mare dect limea golului adiacent,
aferent cutei inferioare;
Panta planului suportului din panouri din tabl cutat va fi 1,5%;
Suprapunerea longitudinal a panourilor din tabl cutat, va fi recomandat de productor;
suprapunerile se vor face numai pe reazeme cu o lime a suprafeei de contact de minim 50
mm, iar panourile vor depi marginile reazemului, de regul, cu cte 50 mm;
Modul de fixare, a panourilor din tabl cutat, pe reazeme i de coasere longitudinal a
acestora va fi minim cea indicat de productor (pentru satisfacerea condiiilor mecanice,
indicate) i va fi stabilit de ctre proiectantul de rezisten (pentru obinerea efectului de
aib).

Art.86
Condiii privind suportul din elemente din lemn sau panouri fibrilemnoase:
(1) Suportul poate fi din:
(i) lamele cu grosimea minim de 18 mm i limea cuprins ntre 8 cm i 15 cm;
(ii) lamele cu grosimea minim de 22 mm i limea cuprins ntre 12 cm i 15 cm;
(iii)
lamele cu grosimea minim de 23 mm i limea maxim de 15 cm;
(iv) Panouri celulozice aglomerate de minim 18 mm grosime;
(2) Elementele suport vor sprijini pe minim trei reazeme i se vor monta prin alturare simpl sau
prin fal cu un spaiu liber (joc) de maxim 2 mm;
(3) Suportul va fi uscat, cu produse biocide i de ignifugare;
(4) Elementele din lemn se vor fixa prin cuie sau uruburi pentru lemn iar panourile celulozice
aglomerate se vor fixa prin uruburi pentru lemn.
Art.87
Produsele termoizolante utilizate n structurile termihidroizolante:
(1) Produsele termoizolante se fabric sub form de plci cu dimensiuni, de regul ( 0,5x1,0 m;
0,5x1,2 m; 0,6x1,0 m; 0,6x1,2 m), cu grosimki diverse (2 cm; 3 cm; 4 cm; 5 cm; 6 cm; 8 cm; 10
cm; 12 cm);
(2) Plcile termoizolante sunt formate din produse omogene, cu densiti diferite n masa plcii sau
produse mixte; produsele omogene cele mai utilizate, sunt:
a) plci din vat mineral VM (bazaltic), omogene sau cu straturi cu densiti diferite
(stratul superior cu densitate mai mare dect restul masei), simple (natur), caerate pe o
fa sau pe ambele (de regul, cu membrane hidroizolante bituminoase);
b) plci din vat de sticl, de regul, natur, utilizate n mic msur (ca ecrane de
mpiedicare a propagrii focului);
c) plci din spum poliuretanuc PVR, natur sau caerate, pe una sau pe ambele fee, de
regul, cu voaluri (mpslitur) din fibre de sticl sau poliesterice;
d) plci din spum poliizocianurat PIR, natur sau caerate, pe una sau pe ambele fee, de
regul, cu voaluri (mpslitur) din fibre de sticl sau poliesterice sau cu membrane
hidroizolante bituminoase;
e) plci din polistiren expandat EPS, de regul, natur;
45

f) plci diverse: din plut aglomerat, sticl spongioas, plci perlitice, etc.
Art.88
Modaliti de montare a plcilor termoizolante:
(1) Prin lipire n total aderen sau semiaderen, pe suport continuu, amorsat i/sau prevzut cu
membran barier contra vaporilor;
(2) Prin lipire n total aderen sau semiaderen, cu fixare mecanic pe suport continuu sau
discontinuu amorsat i/sau prevzut cu membran barier contra vaporilor (de exemplu aplicat
pe tabl cutat);
(3) Montare flotant (simpl aezare) cu fixare mecanic direct pentru poziionare i indirect prin
fixarea structurii hidroizolante (prin plcile termoizolante) la suport;
(4) Se pot prevedea sisteme mixte de montare a plcilor termoizolante; de exemplu un prim strat
termoizolant fixat mecanic (definitiv) pe suport i al doilea strat de termoizolant aplicat prin
lipire n total aderen, pe primul strat.
Art.89
Modaliti de fixare mecanic a plcilor termoizolante:
(1) Fixare de poziionare ce necesit fixare definitiv a primului strat al structurii hidroizolante; de
regul, fixarea de poziionare se realizeaz cu dou elemente de fixare pe axa mecanic a plcii;
(2) Fixare total (definitiv) numai la plcile termoizolante caerate cu o membran hidroizolant
sau la plcile pe care se pot lipi/suda n total aderen structura hidroizolant;
Art.90
Elemente cu fixare mecanic a plcilor termoizolante:
(1) uruburi speciale (cu lungimea mai mare dect grosimea plcii/plcilor termoizolante) fixate
prin rondel circular, oval sau rectangular;
(2) Elementele speciale din mase plastice tip ciuperc pahar (fixe sau tasabile pe nlime),
cilindrice cu guler, ce permit fixarea la partea inferioar a lor, cu uruburi scurte sau nituri.
Art.91
Sisteme i elemente de fixare a plcilor termoizolante i de fixare a primului strat hidroizolant din
cadrul structurilor termohidroizolante sunt indicate (i oferite) de productorii de sistem (de
hidroizolaii cu membrane bituminoase sau polimerice).
Art.92
Structura termoizolant ce cuprinde plcile termoizolante, bariera contra vaporilor i difuzia va fi
prevzut i dimensionat n conformitate cu reglementrile specifice n vigoare, privind calculul
termotehnic i higrotermic.

SECIUNEA a 2-a: Fixarea mecanic a structurilor hidroizolante


Art.93
Structurile hidroizolante fixate mecanic vor fi minim bistrat; promul strat (de baz) de membran
hidroizolant fixat mecanic pe suport iar stratul/straturile supeerioare lipite n total aderen pe
primul strat.
Art 94
Membranele hidroizolante ce pot fi fixate mecanic vor fi special nominalizate de productorul de
sistem care va indica (i furniza) i tehnologia de montare cu sistemul de fixare, densitate mijloacelor
de fixare (cuie, uruburi specifice, aibe, rozete, etc.), funcie de zonarea geoclimatic (nivelul
presiunilor de suciune), de nlimea constuciei (de regul sun 20 m i peste 20 m) i de zonele

46

aferente suprafeei acoperiului col, margine, n jurul elementelor ce depesc panoul nvelitorii,
strpungerii, etc.);
Productorul de sistem (de membrane ce se pot fixa mecanic) va indica i tehnilogia de asigurare a
etaneitii suprapunerilor funcie de sistemul de fixare (aibe, rondele) recomandat; suprapunerea
etan, minim, peste marginea exterioar a elementului de fixare (aib/rondel) va fi de 5 cm.
Art.95
Numrul fixrilor mecanice, de cmp curent, se va determina funcie de rezistena fixrii n suport, a
rezistenei de smulgere a membranei hidroizolante din elementul de fixare (fixare mecanic i
aib/rondel), de zonarea geografic, de situare, privind aciunea vntului, i de nivelul de expunere
(adpostit, neadpostit).
Art.96
Fixarea mecanic a (primului) primului strat hidroizolant, de regul va fi:
(1) Pe conturul acoperiurilor linia fixrilor mecanice va fi la 5 cm de margine;
(2) Distana minim dintre fixrile mecanice va fi de 18 cm; n cazul suportului din panouri din tabl
cutat aceast tabl cutat se va corela cu limea superioar a cutelor panourilor din tabl cutat
(este posibil pe o cut s fie necesar o singur fixare iar pe cuta alturat s fie necesare dou
fixri ce vor respecta distana minim, indicat);
(3) Pe contur, pe cldirile cu nlimea <20 m, numrul fixrilor mecanice se va dubla n benzi la
distan de cca. 50 cm, pe minim 1 m ltime (pentru atice i elemente ce strpung i depsesc
planul nvelitorii cu maxim 1 m);
(4) Pe contur, pentru cldirile 20 m i pentru cldirile adiacente ce depesc planul nvelitorii,
laimea zonei cu dublarea numrului fixrilor mecanice va fi:
h= nlimea cldirii hidroizolante sau a cldirii
adiacente (peste nltimea cldirii hidroizolante
limea zonei cu numrul fixrilor mecanice
dublate

h 20 m

h> 20 m i 30 m

h> 30 m i 40 m

2m

3m

4m

(5) Prin dublarea numrului fixrilor mecanice pe cuantumul acoperiurilor rezult manopera
acestora de patru ori n zonele de col;
(6) Fixrile mecanice ale structurilor hidroizolante sunt exemplificate n anexa 2.

47

structur hidroizolant autoprotejat


suport amorsat

structur hidroizolant autoprotejat


ANEXA 1
termoizolaie
barier vapori cu sau fr strat de difuziune
STRUCTURILOR
HIDROIZOLANTE
I
suport amorsat

PREZENTARE
EXPLICATIV
A
TERMOHIDROIZOLANTE CU MEMBRANE BITUMINOASE LA TERASE
1. Acoperiuri terase necirculabile

a)

protecie grea din pietri pe strat de separare sau din


dale pozate n pat de nisip
structur hidroizolant
strat de separare
element suport

b)

protecie grea din pietri pe strat de separare sau din


dale pozate n pat de nisip
structur hidroizolant
strat de separare
termoizolaie
barier de vapori cu sau fr strat de difuzie
48
suport amorsat

c)

d)

2. Acoperiuri teras necirculabile cu termoizolaie ranversat

a)

b)

protecie grea din pietri

strat de separare
termoizolaie (cu pori nchii)
structur hidroizolant cu sau fr strat de difuzie
suport amorsat

protecie cu dale pozate n pat de nisip sau ap


strat de separare
termoizolaie (cu pori nchii)
structur hidroizolant cu sau fr strat de difuzie
suport amorsat

49

3. Acoperiuri necirculabile cu suport din astereal

a)
structur hidroizolant autoprotejat
suport din astereal amorsat

b)

structura hidroizolant autoprotejat


termoizolaie
barier vapori fixat cu cuie
suport din astereal

50

4. Acoperiuri necirculabile cu suport din panouri metalice profilate


a)

structur hidroizolant autoprotejat

termoizolaie

suport din panouri metalice profilate


Not: termoizolaia i primul strat hidroizolant se fixeaz mecanic
pe suportul din panouri metalice profilate care vor avea limea
cutei superioare (suport) mai mare dect limea golului rezultat al
cutei inferioare;
b)

a)

b)

5. Terase utilitare circulabile pietonal

structur hidroizolant autoportant


suport din panouri metalice profilate, complexe,
dale pozate n pat de nisip sau n mortar
termoizolante
Not:hidroizolaia sede
lipete
n total
aderen
pe panourile metalice
ciment
i strat
de separare
profilate, complexe,
uzinate.
termoizolate,
structur hidroizolant

strat de separare
element suport

dale pe ploturi
structur hidroizolant
strat de separare
element suport

dale pozate n pat de nisip sau n mortar


de ciment i strat de separare
strat de separare
termoizolaie pe strat de separare
barier vapori cu sau fr strat difuzie
element suport amorsat

dale pe ploturi
structur hidroizolant
strat de separare
termoizolaie pe strat de separare
barier vapori cu sau fr strat difuzie
element suport amorsat

a)

b)

51

c)

d)

6. Terase utilitare circulabile, carosabile

a)

b)

mbrcminte asfaltic compactat


structur hidroizolant
element suport amorsat

dale autoblocante pozate n pat de nisip


structur hidroizolant
termoizolaie rigid
barier vapori (fr difuzie)
element suport amorsat

52

7. Terase utilitare grdin

a)

b)

strat vegetal
strat filtrant
strat drenant din elemente preformate sau
pietri
structur hidroizolant
strat de separare
element suport

strat vegetal
strat filtrant
strat drenant din elemente preformate sau
pietri
structur hidroizolant
strat de separare
termoizolaie
barier vapori cu sau fr strat difuzie
element suport amorsat

53

ANEXA 2
PRINCIPII DE ALCTUIRE ALE PRINCIPALELOR TIPURI DE RACORDURI NTRE
SUPRAFEE I LA ELEMENTE DE CONSTRUCIE CU MEMBRANE BITUMINOASE LA
ACOPERIURI
1.Principii de racordare ale structurilor hidroizolante de pe suprafeele orizontale pe cele verticale, cu
poziionarea stratului suplimentar de ntrire a hidroizolaiei
a. Structuri hidroizolante racordate n unghi drept
HIDROIZOLAIE MONOSTRAT

HIDROIZOLAIE BISTRAT

HIDROIZOLAIE TRISTRAT

b) Structuri hidroizolante racordate la vertical, cu scaf la 45

54

c) Racordarea structurilor termohidroizolante

2. Principii de racordare a hidroizolaiei la marginea suprafeei acoperiurilor fr rebord


a) Racordare direct pe cornia cu lcrimar

PRINCIPII DE HIDROIZOLARE A ROSTURILOR


ROSTURI
CU REBORD
Structuri
hidroizolante
acoperire cu material hidroizolant lipit

acoperire cu element prefabricat

Structuri termohidroizolante

b) Racordarea pe corni cu or cu picurtor din profil metalic sau polimeric:


ANEXA NR.6E
ROSTURI DE RACORDARE A HIDROIZOLAIEI LA DEFLECTOARE
I RECEPTOARE PLUVIALE
DEFLECTOR SIMPLU

Structuri hidroizolante

DEFLECTOR DUBLU

Structuri termohidroizolante

c) Racordarea pe or cu picurtor din profil metalic sau polimeric:


NOT:

La piesele receptor pluvial metalic (plumb, aluminiu), peste gulerul acestora se


va prevede un strat hidroizolant suplimentar, superior, aplicat sub structura
hidroizolant, cu depirea marginii gulerului cu minim 10 cm

3) Principii destructuri
racordare
a hidroizolaiei pe atice
hidroizolante
structuri termohidroizolante
a) Racordare
b) Racordare
c) Racordare
d) Racordare cu
direct
cu glaf
cu copertin
element prefabricat

55

ANEXA NR.7

PRINCIPII DE HIDROIZOLARE A ELEMENTELOR I PRILOR DE CLDIRE


MPOTRIVA EXFILTRAIILOR
NOT:

Peste hidroizolaie se vor aplica apele i tencuielile slab armate ca suport al


stratului de uzur i de finisare
HIDROIZOLAIE ORIZONTAL

ANEXA NR.8
4. Principii de hidroizolare a rosturilor
Rosturi cu rebord
a) acoperire cu material hidroizolant lipit

b) acoperire cu element prefabricat

56

5. Principii de racordare a hidroizolaiei la deflectoare i receptoare pluviale


DEFLECTOR SIMPLU

DEFLECTOR DUBLU

57

Nota:La piesele receptor pluvial sub i peste gulerul acestora se va prevede un strat hidroizolant
suplimentar, superior, aplicat sub structura hidroizolant, cu depirea marginii gulerului cu minim 10
cm.

ANEXA 3

58

PRINCIPII DE HIDROIZOLARE A ELEMENTELOR I PRILOR DE CLDIRE


SUBTERANE MPOTRIVA EXFILTRAIILOR I INFILTRAIILOR
Principii de racordare a structurilor hidroizolante mpotriva exfiltraiilor de pe suprafeele orizontale pe
cele verticale, cu poziionarea stratului suplimentar de ntrire a hidroizolaiei (peste hidroizolaie se
vor aplica apele i tencuielile ca protecie la montarea armturilor i la turnarea betoanelor):

2. Principii de hidroizolare a soclurilor i fundaiilor la cldiri cu sau fr subsol mpotriva infiltraiilor


59

a) Hidroizolarea soclurilor i fundaiilor; principii uzuale de hidroizolare:

3. Principii de hidroizolare a rosturilor


60

a) Principii de hidroizolare a rosturilor contra apelor fr presiune hidrostatic

b) Principii de hidroizolare a rosturilor contra apelor cupresiune hidrostatic

4. Principii de hidroizolare a strpungerilor contra apelor cu presiune hidrostatic


61

a) Strpungere n sistem flan fix i flan mobil:

b) Strpungere n sistem flan fix i flan mobil

ANEXA 4
62

PREZENTAREA CARACTERISTICILOR AUXILIARE A PRODUSELOR HIDROIZOLANTE


1. Parametri auxiliari, de evaluare a membranelor hidroizolante, bituminoase i/sau polimerice.
a) Rezistena la sfiere (S); relev fora necesar pentru sfierea unei epruvete din material
hidroizolant care suport n zona de maxim solicitare o distribuie neuniform a solicitrii la
traciune. Valoarea forei se exprim n N. Acest parametru este util pentru calcularea i
verificarea sistemului de asigurare a unei membrane fixate mecanic, n special n cazul
suprafeelor verticale sau cu pant accentuat;
b) Stabilitatea dimensional (D); relev variaia dimensional a membranelor dar i a materialelor
i structurilor din mase omogene cu aplicare pelicular, expuse la temperaturi nalte. Stabilitatea
dimensional se enun pentru sensul longitudinal i sensul transversal. Stabilitatea
dimensional este relevant n special pentru membranele polimerice;
c) Delaminarea (L), se caracterizeaz prin prezena sau absena fenomenului de desprindere a
masei hidroizolante de acoperire n raport cu armtura, n condiii date de temperatur i
umiditate;
d) Aderena autoproteciei (Aa); acest parametru relev nivelul aderenei materialului granular de
protecie depus din fabricaie pe membranele bituminoase n urma aciunii mecanice de
abraziune. Nu se vor admite sorturile ce comport pierderi ale materialului granular de
autoprotecie mai mari de 30% n stare uscat i mai mari de 50% n stare umed;
e) Etaneitatea mbinrilor (J); acest parametru relev nivelul de etaneitate al mbinrilor
(suprapunerilor) dintre dou membrane. mbinrile trebuie s asigure etaneitatea la o presiune
(de aer) de minim 10 KPa timp de 30 minute;
f) Rezistena la traciune a mbinrilor (Jt); acest parametru relev nivelul de rezisten la fore de
traciune aplicate transversal mbinrii dintre dou membrane. Nivelul de rezisten la traciune
a mbinrilor se identific prin fora la care apare ruptura n zona de aderen sau n afara
acesteia.
2. Parametri auxiliari, de evaluare a membranelor hidroizolante omogene cu aplicare pelicular
a) Adezivitatea (Az); acest parametru relev nivelul de aderen (lipire) pe care l comport
straturile hidroizolante din mase omogene cu aplicare pelicular, ntre ele, pe suport i faa de
straturile de armare;
b) Uscare (U); acest parametru relev timpul de uscare (reticulare) a straturilor hidroizolante din
mase omogene cu aplicare pelicular. n general acest timp trebuie s fie uzual de 24 ore i
maxim de 48 ore;
c) Vscozitatea (V); acest parametru relev nivelul de lucrabilitate (fluiditate) al maselor omogene
cu aplicare pelicular, clasificat astfel:
vscozitate redus (amorse pelicule hidroizolante subiri); cu nivel de viscozitate de 100
centipoise permite aplicarea prin stropire sau pensulare;
viscozitate medie (pelicule hidroizolante, mase de lipire); cu nivel maxim de viscozitate de
200 centipoise permite aplicarea la cosoroab, prin pensulare i periere;
viscozitate mare (mase hidroizolante i de lipire); cu nivel de viscozitate mai mare de 200
centipoise permite aplicarea la cosoroab, prin periere i pcluire (1 centipoise = 1
mPa/s);
d) Omogeneitate i stabilitate la depozitare (segregare);. Nu se admit segregri sau aglomerri n
materialul depozitat minim 7 zile;
e) Stabilitate la cald la 70C pe pant de 45 (100%) timp de 2 ore, pentru masele omogene cu
aplicare pelicular, nearmate, nu se admit scurgeri;
f) Coninut de substan uscat din masa materialului hidroizolant cu aplicare pelicular;
63

g) Combustibilitatea; acest parametru se relev prin nivelul de combustibilitate, cu specificarea


noxelor sau a topiturilor ce se produc n timpul arderii. Acest parametru se refer la membranele
hidroizolante i la cele din mase omogene cu aplicare pelicular i va fi avut n vedere n
contextul NPSI n vigoare;
h) Inflamabilitatea; acest parametru se relev prin temperatura la care se poate produce aprinderea.
Acest parametru se refer n special la materialele hidroizolante din mase omogene cu aplicare
pelicular ce conin solveni organici i va fi avut n vedere n contextul NPSI n vigoare.

ANEXA 5
EXEMPLIFICRI PRIVIND ACIUNILE MEDIULUI
64

1. Aciunile generale ale mediului asupra hidroizolaiilor expuse n mod direct sau indirect:

Factor de mediu
Ageni de mediu-UM
a.

Niveluri de severitate

CLIM:
temperatur:
temperaturi sczute: C;
temperaturi ridicate: C;
variaie de temperatur: C/minut.
umiditatea relativ a aerului: %;
presiune vnt: KPa;
precipitaii:
intensitatea (debitul) ploii: l/m2/minut;
viteza de iroire a apei: m/s;
zpad transportat (intensitate): kg/m2/s;
grindin-energ de impact: J;
radiaie solar (efecte termice) intensitate: W/m2

-35; -25; -20; -15; -10; -5; 0


+20; +40; +60; +85; +100; +120;
0,5; 1; 3; 5;
20; 40; 60; 75; 85; 100;
0,3; 0,55; 1; 2; 3;
0,5; 1; 2; 5; 10; 15;
0,5; 1; 3; 10; 20; 30;
0,5; 1; 3;
1; 10; 40; 150, 250;
300; 500; 700; 1000; 1120;

b.

SUBSTANE CHIMICE ACTIVE: mg/m:


sare marin
dioxid de sulf
hidrogen sulfurat
oxizi de azot
amoniac
clor
acid clorhidric
acid fluorhidric

c.

SUBSTANE MECANIC ACTIVE:


sedimentare pulberi, viteza de sedimentare mg/m2/h;
ncrcare static (aglomerare): KPa.

300; 1000; 30000; 40000;


1; 3; 5; 10; 20; 30; 40; 100; 300
0,01; 0,1; 0,3; 0,5; 1; 3; 10; 15; 30; 50; 100;
0,01; 0,1; 0,3; 0,5; 1; 3, 10; 20; 30; 100
0,3; 1; 3, 10; 35; 175
0,01; 0,1; 0,3; 0,6, 1; 3
0,01; 0,1; 0,5, 1; 5
0,003; 0,01; 0,03; 0,1; 1
1; 3, 10, 20; 30; 40, 80
0,1; 0,5, 1; 2; 3; 5, 10; 20; 50; 100

2.Factorii i agenii de mediu se caracterizeaz prin niveluri de acionare, specifici:


a) Ploaie: se caracterizeaz prin urmtorii parametri fizici:
intensitatea ploii;
distribuia diametrului picturii;
distribuia vitezei de cdere;
temperatura picturilor.
Caracteristicile ploii (de la medie pn la lunga durat)
Tipul de ploaie
Ploaie uoar
Ploaie moderat
Ploaie intens
Ploaie puternic
Avers

Intensitatea limit
superioar-l/h
1,0
4,0
15
40
100

Diametrul caracteristic
al picturii-mm
0,1-0,5
0,5-1
1-2
2-5
3

Viteza de cdere-m/s
0,25-1
1-2
2-4
4-7
6

3. Grindina: se caracterizeaz prin urmtorii parametri fizici ai boabelor de ghea:


a) diametrul;
65

b) densitatea;
c) viteza de cdere;
d) energia de impact.
Se iau n considerare boabele de grindin cu dimensiuni mari ce au efect distrugtor.
Densitatea boabelor este de circa 900 kg/m3.
Viteza de cdere se determin cu formula:
V = 5,16 d
unde
V = viteza de cdere, n m/s
d = diametrul boabelor, n mm
Energia de impact este calculat funcie de masa i viteza de cdere.
Caracteristicile boabelor de grindin (pentru diametre peste 20 mm; exemplificare
Diametru
mm
20
50
60
70
80
90
100

Masa
g
4
59
102
162
241
344
471

Viteza de cdere
m/s
23
36
40
43
46
49
52

Energia de impact
J
1
39
81
151
257
411
627

4. Zpada: densitatea zpezii czute pe suprafee prezint mari variaii:


- Zpada proaspt czut are o densitate variind ntre 70 kg/m3 i 150 kg/m3, iar densitatea
unei zpezi vechi, tasate, atinge de la 200 kg/m3 la 400 kg/m3;
- Zpad transparent: este o combinaie de vnt cu zpad, n aceste condiii particulele
fine pot ptrunde prin fante sau prin mbinri.
Fluxul orizontal de zpad funcie de nlime; exemplificare
nlimea deasupra
solului
m
10
1
0,5
0,1

Fluxul orizontal de zpad


g/m2sec
310
560
800
3000

5. Praf-nisip: principalul constituent al nisipurilor i prafurilor prezente n natur este cuarul;


eroziunea materialelor se produce n condiia n care praful i nisipul sunt combinate la cureni de
aer cu vitez mare i/sau durate mari de acionare.
- Dimensiunea particulelor-caracterizare:
o praf fin:
pn la 75 m;
o praf grosier: de la 75 m pn la 150 m;
o nisip:
de la 150 m pn la 1000 m.
Concentraii caracteristice de praf i nisip; exemplificare
Zonare
Rural i suburban
Urban
Industrial

Concentraie
g/m3
40-110
100-450
500-2000

Sedimentare de praf i nisip; exemplificare

66

Zonare
Rural i suburban
Urban
Industrial

Sedimentare de praf i nisip


mg/m2/ or
0,4-15
15-40
40-80

- Sedimentarea prafului i nisipului se poate produce:


o prin sedimentarea n aer stagnant (staie);
o prin sedimentare pe suprafee acoperite;
o prin atracie electrostatic;
o prin captare n deschideri nguste;
- Ptrunderea prafului i nisipului poate s apar astfel:
o transport n interior prin circulaie forat a aerului;
o transport n interior prin agitaie termic a aerului;
o pompare la interior prin dilatare i compresie termic a aerului sau prin variaia presiunii
atmosferice.

ANEXA 6
67

EXEMPLIFICRI PRIVIND NCRCRI DATORATE SUCIUNII VNTULUI


Specificaiile prezentei anexe se refer la evaluarea ncrcrilor datorate suciunii vntului, care pot
avea ca efect smulgerea straturilor hidroizolante. Valoarea suciunii din vnt trebuie luat n
considerare, dup caz, la dimensionarea pieselor de prindere a structurii termo-hidroizolante de stratul
de rezisten al acoperiului, aderena structurii hidroizolante la suport, respectiv greutatea stratului de
lestare.
Suciunea din vnt a fost evaluat pentru diverse viteze ale vntului, pentru dou cazuri uzuale de
construcii nchise, cu form dreptunghiular n plan:
acoperi nclinat, n dou ape cu panta mic sau orizontal (raport nlime cldire/deschidere
cldire H/l 2,0) conform tabel nr.1;
acoperi sub form de arc circular (raport nlime arc la cheie/deschidere cldire
f/l =0,5)
conform tabel nr.2.
Not:
Prevederile prezentei anexe nu se refer la calculul elementelor structurale la aciunea vntului i
nici la calculul la aciunea vntului a acoperiului. Acest calcul se face n conformitate cu
reglementrile tehnice n vigoare, n funcie de zona eolian i altitudinea la care este amplasat
construcia. Se menioneaz c n cadrul prezentei Anexe, a fost luat n considerare numai
suciunea datorat vntului, nu i presiunea.
Formula de calcul a suciunii din vnt este:
P = x cn2 x gv ;
P suciunea din vnt, n [kN/m2]
- coeficient dinamic pentru majoritatea construciilor cu nlimea mai mic de 36 m,
= 1,00
cn2 = coeficientul rezultantei aciunii vntului
cn2 = - 0,8 - pentru acoperi nclinat n dou ape (cu panta mai mic de 600) sau orizontal, la
construcii nchise, cu form dreptunghiular n plan (raport nlime cldire/deschidere cldire
H/l 2,0)
cn2 = - 1,2 - pentru acoperi sub form de arc circular, la construcii nchise, cu form
dreptunghiular n plan (raport nlime arc la cheie/deschidere cldire f/l =0,5)
gv = suciune dinamic de baz, n funcie de viteza vntului, n [kN/m2]
gv = v2/1630, n care
v - viteza vntului, n [m/s]
Vitez vnt
(m/s)
10
20
30
40

(km/h)
36
72
108
144

Sucune dinamic de
baz
(kN/m2)
0,06
0,25
0,55
0,98

Suciune din vnt


(kN/m2)
0,05
0,20
0,44
0,78

Acoperi nclinat, n dou ape (cu panta mai mic de 60 0) sau orizontal, la construcii nchise, cu form
dreptunghiular n plan (raport nlime cldire/deschidere cldire H/l 2,0)

68

Vitez vnt
(m/s)
10
20
30
40

(km/h)
36
72
108
144

Suciune dinamic de
baz
(kN/m2)
0,06
0,25
0,55
0,98

Suciune din vnt


(kN/m2)
0,07
0,30
0,66
1,18

Acoperi sub form de arc circular, la construcii nchise, cu form dreptunghiular n plan (raport
nlime arc la cheie/deschidere cldire f/l =0,5)

ANEXA 7
69

EXEMPLIFICRI PRIVIND EVALUAREA PERFORMANELOR DE IZOLARE TERMIC


LA STRUCTURILE TERMOHIDROIZOLANTE
1. GENERALITI
La cldirile nclzite, n alctuirea acoperiului trebuie prevzut un strat termoizolant, astfel nct
construcia s satisfac cerina de izolaie termic i economie de energie.
n prezenta anex, se prezint valorile rezistenelor termice specifice unidirecionale (n camp curent necorectate), pentru principalele tipuri de alctuiri termo-hidroizolante utilizate pe scar larg la cldiri
nclzite.
Evaluarea rezistenelor termice specifice unidirecionale s-a fcut n conformitate cu prevederile din
Normativ privind calculul termotehnic al elementelor de construcie ale cldirilor indicativ C1072005 Partea a 3 a indicativ C 107/3.
Conductivitile termice de calcul ale materialelor din alctuirea structurilor termo-hidroizolante luate
n considerare la evaluarea rezistenelor termice sunt n conformitate cu ANEXA A din normativ C1072005 Partea a 3 a indicativ C 107/3.
2. SIMBOLURI I UNITI DE MSUR
a) Rsi rezisten termic superficial interioar [m2K/W]
Rsi = 0,125 m2K/W pentru cldiri nclzite, n regim de iarn
b) Rsie rezisten termic superficial exterioar [m2K/W]
Rse = 0,042 m2K/W pentru sensul fluxului termic din interior spre exterior, n regim de
iarn
c) Rs - rezisten termic specific a unui strat omogen de material [m2K/W]
d) R - rezisten termic specific unidirecional a structurii termo-hidroizolante a acoperiului
[m2K/W]
e) U coeficient de transfer termic unidirecional (transmitan termic unidirecional) a
structurii termo-hidroizolante a acoperiului [W/(m2K)]
f) conductivitate termic de calcul [W/(mK)]
3. RELAII DE CALCUL
Rs = d/ [m2K/W]
R = Rsi + (d/ ) + Rsie [m2K/W] - pentru structuri etane
R = Rsi + (d/ ) + Rsii [m2K/W] - pentru structuri care includ la partea exterioar un strat de aer
puternic ventilate (n cast caz, Rsie = Rsii)
U = 1/R [W/(m2K)]

70

4. VALOAREA CONDUCTIVITII TERMICE DE CALCUL PENTRU MATERIALELE DIN


COMPONENA ALCTUIRILOR TERMO-HIDROIZOLANTE PREZENTATE
Material

beton armat
beton de pant
ap de ciment
tabl oel
plci din ciment armat pentru panouri tip ROMPAN
fii armate din betoane celulare (BCA)
plci termoizolante din BCA GBN - T
hidroizolaie bituminoas
pietri
nisip
dale din beton
plci rigide din vat mineral
polistiren expandat
poliuretan celular
poliizocianat

Conductivitate termic de
calcul

[W/(mK)]
1,74
1,16
0,93
58
0,35
0,28
0,22
0,17
0,70
0,58
1,16
0,040
0,044
0,042

5. REZISTENE TERMICE SPECIFICE UNIDIRECIONALE PENTRU DIVERSE


ALCTUIRILI TERMO-HIDROIZOLANTE DE ACOPERIURI LA CLDIRI NCLZITE
5.1. Panouri Termo-Hidroizolante
a) Tabelul 1 Panouri complexe termoizolante cu o fa din tabl profilat din oel i o fa cu
hidroizolaie bituminoas
Alctuire panou:
fa tabl profilat din oel
termoizolaie (tip i grosimi conform tabel)
hidroizolaie bituminoas:
-1 strat 4 mm grosime (varianta 1);
-2 straturi 7 mm. grosime (varianta 2)

Varianta 1

Varianta 2
71

Hidroizolaie bituminoas - 1 strat


Grosime
strat
termoizolant

[m]
0,05
0,08
0,10
0,12
0,15
0,18
0,20
0,05
0,08
0,10
0,12
0,15
0,18
0,20
0,05
0,08
0,10
0,12
0,15
0,18
0,20

Rezisten
termic
specific
unidirecional

Coeficient de
transfer termic
unidirecional

Hidroizolaie bituminoas - 2 straturi


Grosime
strat
termoizolant

Rezisten
termic
specific
unidirecional

[m2K/W]
[W/m2K]
[m]
[m2K/W]
Izolaie termic din plci din vat mineral
1,441
0,694
0,05
1,458
2,191
0,456
0,08
2,208
2,691
0,372
0,10
2,708
3,191
0,313
0,12
3,208
3,941
0,254
0,15
3,958
4,691
0,213
0,18
4,708
5,191
0,193
0,20
5,208
Izolaie termic din polistiren
1,327
0,754
0,05
1,345
2,009
0,498
0,08
2,026
2,463
0,406
0,10
2,481
2,918
0,343
0,12
2,935
3,600
0,278
0,15
3,617
4,281
0,233
0,18
4,299
4,736
0,211
0,20
4,754
Izolaie termic din poliuretan celular sau poliizocianat
1,381
0,724
0,05
1,399
2,095
0,477
0,08
2,113
2,571
0,389
0,10
2,589
3,048
0,328
0,12
3,065
3,762
0,266
0,15
3,780
4,476
0,223
0,18
4,494
4,952
0,202
0,20
4,970

Coeficient de
transfer termic
unidirecional

[W/m2K]
0,686
0,453
0,369
0,312
0,253
0,212
0,192
0,744
0,493
0,403
0,341
0,276
0,232
0,210
0,715
0,473
0,386
0,326
0,264
0,222
0,201

72

b) Tabelul 2. Panouri complexe termoizolante cu o fa din ciment armat i o fa cu hidroizolaie


bituminoas
Alctuire panou:
fa ciment armat - 10 mm grosime
termoizolaie (tip i grosimi conform tabel)
hidroizolaie bituminoas:
-1 strat 4 mm grosime (varianta 1)
-2 straturi 7 mm. grosime (varianta 2)
Varianta 1
Hidroizolaie bituminoas - 1 strat
Grosime
strat
termoizolant

[m]
0,05
0,08
0,10
0,12
0,15
0,18
0,20
0,05
0,08
0,10
0,12
0,15
0,18
0,20
0,05
0,08
0,10
0,12
0,15
0,18
0,20

Rezisten
termic
specific
unidirecional

Coeficient de
transfer termic
unidirecional

Varianta 2
Hidroizolaie bituminoas - 2 straturi
Grosime
strat
termoizolant

Rezisten
termic
specific
unidirecional

[m2K/W]
[W/m2K]
[m]
[m2K/W]
Izolaie termic din plci din vat mineral
1,469
0,681
0,05
1,487
2,219
0,451
0,08
2,237
2,719
0,368
0,10
2,737
3,219
0,311
0,12
3,237
3,969
0,252
0,15
3,987
4,719
0,212
0,18
4,737
5,219
0,192
0,20
5,237
Izolaie termic din polistiren
1,355
0,738
0,05
1,373
2,037
0,491
0,08
2,055
2,492
0,401
0,10
2,509
2,946
0,339
0,12
2,964
3,628
0,276
0,15
3,646
4,310
0,232
0,18
4,328
4,764
0,210
0,20
4,782
Izolaie termic din poliuretan celular sau poliizocianat
1,409
0,709
0,05
1,427
2,124
0,471
0,08
2,141
2,600
0,385
0,10
2,618
3,076
0,325
0,12
3,094
3,790
0,264
0,15
3,808
4,505
0,222
0,18
4,522
4,981
0,201
0,20
4,999

Coeficient de
transfer termic
unidirecional

[W/m2K]
0,673
0,447
0,365
0,309
0,251
0,211
0,192
0,728
0,487
0,398
0,337
0,274
0,231
0,209
0,701
0,467
0,382
0,323
0,262
0,221
0,200

5.2.Structuri termo-hidroizolante de acoperiuri montate strat cu strat, cu panta asigurat de elementul


de rezisten al planeului
c)Tabelul nr. 3 Structur termo - hidroizolant cu membrane bituminoase pe planeu din fii din
betoane uoare (celulare BCA) armate
Alctuire acoperi:
73

fie din BCA - 20 cm grosime (Rs = 0,71 m2K/W)


termoizolaie (tip i grosimi conform tabel)
hidroizolaie bituminoas:
-1 strat 4 mm grosime (varianta 1)
-2 straturi 7 mm. grosime (varianta 2)

Varianta 1
Hidroizolaie bituminoas - 1 strat
Grosime
strat
termoizolant

[m]
0,05
0,08
0,10
0,12
0,15
0,18
0,20
0,05
0,08
0,10
0,12
0,15
0,18
0,20
0,05
0,08
0,10
0,12
0,15
0,18
0,20

Rezisten
termic
specific
unidirecional

Coeficient de
transfer termic
unidirecional

Varianta 2
Hidroizolaie bituminoas - 2 straturi
Grosime
strat
termoizolant

Rezisten
termic
specific
unidirecional

[m2K/W]
[W/m2K]
[m]
[m2K/W]
Izolaie termic din plci din vat mineral
2,155
0,464
0,05
2,172
2,904
0,344
0,08
2,992
3,405
0,294
0,10
3,422
3,905
0,256
0,12
3,922
4,655
0,215
0,15
4,672
5,405
0,185
0,18
5,422
5,905
0,169
0,20
5,922
Izolaie termic din polistiren
2,041
0,490
0,05
2,059
2,723
0,367
0,08
2,741
3,177
0,315
0,10
3,195
3,632
0,275
0,12
3,650
4,314
0,232
0,15
4,331
4,996
0,200
0,18
5,013
5,450
0,183
0,20
5,468
Izolaie termic din poliuretan celular sau poliizocianat
2,095
0,477
0,05
2,113
2,809
0,356
0,08
2,827
3,286
0,304
0,10
3,303
3,762
0,266
0,12
3,780
4,476
0,223
0,15
4,494
5,190
0,193
0,18
5,208
5,667
0,176
0,20
5,684

Coeficient de
transfer termic
unidirecional

[W/m2K]
0,460
0,342
0,292
0,255
0,214
0,184
0,169
0,486
0,365
0,313
0,274
0,231
0,199
0,183
0,473
0,354
0,303
0,264
0,222
0,192
0,176

d) Tabelul nr. 4 Structur termo - hidroizolant pe planeu din fii cu goluri din beton
armat/precomprimat, cu hidroizolaie bituminoas
Alctuire acoperi:
fie cu goluri - 20 cm grosime (Rs = 0,15 m2K/W)
termoizolaie (tip i grosimi conform tabel)
hidroizolaie bituminoas:
74

-1 strat 4 mm grosime (varianta 1)


-2 straturi 7 mm. grosime (varianta 2)
Varianta 1
Hidroizolaie bituminoas - 1 strat
Grosime
strat
termoizolant

[m]
0,05
0,08
0,10
0,12
0,15
0,18
0,20
0,05
0,08
0,10
0,12
0,15
0,18
0,20
0,05
0,08
0,10
0,12
0,15
0,18
0,20

Rezisten
termic
specific
unidirecional

Coeficient de
transfer termic
unidirecional

Varianta 2
Hidroizolaie bituminoas - 2 straturi
Grosime
strat
termoizolant

Rezisten
termic
specific
unidirecional

[m2K/W]
[W/m2K]
[m]
[m2K/W]
Izolaie termic din plci din vat mineral
1,590
0,629
0,05
1,608
2,340
0,427
0,08
2,358
2,840
0,352
0,10
2,858
3.340
0,299
0,12
3,358
4,090
0,244
0,15
4,108
4,840
0,206
0,18
4,858
5,340
0,187
0,20
5,358
Izolaie termic din polistiren
1,477
0,677
0,05
1,494
2,159
0,463
0,08
2,176
2,613
0,383
0,10
2,631
3,068
0,326
0,12
3,085
3,749
0,267
0,15
3,767
4,431
0,226
0,18
4,449
4,886
0,205
0,20
4,904
Izolaie termic din poliuretan celular sau poliizocianat
1,531
0,653
0,05
1,549
2,245
0,445
0,08
2,263
2,721
0,367
0,10
2,739
3,198
0,313
0,12
3,215
3,912
0,256
0,15
3,930
4,626
0,216
0,18
4,644
5,102
0,196
0,20
5,120

Coeficient de
transfer termic
unidirecional

[W/m2K]
0,622
0,424
0,350
0,298
0,243
0,206
0,186
0,669
0,459
0,380
0,324
0,265
0,225
0,204
0,646
0,442
0,365
0,311
0,254
0,215
0,195

5.3.Structuri termo-hidroizolante de acoperiuri teras


e) Tabelul 5 Acoperi - teras circulabil (dale pozate pe nisip)
Alctuire acoperi:
Planeu din beton armat - 13 cm grosime
Barier vapori + strat difuzie
Strat de pant:
-din BCA GBN - T 15 cm grosime medie (varianta 1)
-din beton de pant 7,5 cm. grosime medie (varianta 2)
Termoizolaie (tip i grosimi conform tabel)
Strat protecie termoizolaie ap slab armat 3 cm. grosime
Barier vapori
Hidroizolaie bituminoas: - 2 straturi 7 mm. grosime
75

Strat nisip pozare dale: 3 cm. grosime


Dale din beton: 3 cm grosime
Varianta 1 strat pant din BCA
Grosime
strat
termoizolant

[m]
0,05
0,08
0,10
0,12
0,15
0,18
0,20
0,05
0,08
0,10
0,12
0,15
0,18
0,20
0,05
0,08
0,10
0,12
0,15
0,18
0,20

Rezisten
termic
specific
unidirecional

Coeficient de
transfer termic
unidirecional

Varianta 2 strat pant din beton de pant


Grosime
strat
termoizolant

Rezisten
termic
specific
unidirecional

[m2K/W]
[W/m2K]
[m]
[m2K/W]
Izolaie termic din plci din vat mineral
2,324
0,430
0,05
1,707
3,074
0,325
0,08
2,457
3,574
0,280
0,10
2,957
4,074
0,245
0,12
3,457
4,824
0,207
0,15
4,207
5,574
0,179
0,18
4,957
6,074
0,165
0,20
5,457
Izolaie termic din polistiren
2,211
0,452
0,05
1,594
2,893
0,346
0,08
2,275
3,347
0,299
0,10
2,730
3,802
0,263
0,12
3,185
4,483
0,223
0,15
3,866
5,165
0,194
0,18
4,548
5,620
0,178
0,20
5,003
Izolaie termic din poliuretan celular sau poliizocianat
2,265
0,441
0,05
1,648
2,979
0,336
0,08
2,362
3,455
0,289
0,10
2,838
3,932
0,254
0,12
3,314
4,646
0,215
0,15
4,029
5,360
0,186
0,18
4,743
5,836
0,171
0,20
5,219

Coeficient de
transfer termic
unidirecional

[W/m2K]
0,586
0,407
0,385
0,289
0,238
0,202
0,183
0,627
0,439
0,366
0,314
0,259
0,220
0,200
0,607
0,423
0,352
0,302
0,248
0,211
0.192

f) Tabelul 6. Acoperi - teras circulabil (dale pe ploturi)


Alctuire acoperi:
Planeu din beton armat - 13 cm grosime
Barier vapori + strat difuzie
Strat de pant:
-din BCA GBN - T 15 cm grosime medie (varianta 1)
-din beton de pant 7,5 cm. grosime medie (varianta 2)
Termoizolaie (tip i grosimi conform tabel)
Strat protecie termoizolaie ap slab armat 3 cm. grosime
Barier vapori
Hidroizolaie bituminoas: 2 straturi 7 mm. grosime
Dale pe ploturi rosturi ntrre dale 2 mm, care realizeaz un strat de aer puternic ventilat

76

Varianta 1 strat pant din BCA


Grosime
strat
termoizolant

[m]
0,05
0,08
0,10
0,12
0,15
0,18
0,20
0,05
0,08
0,10
0,12
0,15
0,18
0,20
0,05
0,08
0,10
0,12
0,15
0,18
0,20

Rezisten
termic
specific
unidirecional

Coeficient de
transfer termic
unidirecional

Varianta 2 strat pant din beton de pant


Grosime
strat
termoizolant

Rezisten
termic
specific
unidirecional

[m2K/W]
[W/m2K]
[m]
[m2K/W]
Izolaie termic din plci din vat mineral
2,33
0,429
0,05
1,713
3,08
0,325
0,08
2,463
3,58
0,279
0,10
2,963
4,08
0,245
0,12
3,463
4,83
0,207
0,15
4,213
5,58
0,179
0,18
4,963
6,08
0,164
0,20
5,463
Izolaie termic din polistiren
2,216
0,451
0,05
1,599
2,898
0,345
0,08
2,281
3,353
0,298
0,10
2,735
3,807
0,263
0,12
3,190
4,489
0,223
0,15
3,872
5,171
0,193
0,18
4,554
5,625
0,178
0,20
5,008
Izolaie termic din poliuretan celular sau poliizocianat
2,270
0,440
0,05
1,653
2,985
0,335
0,08
2,367
3,461
0,289
0,10
2,844
3,937
0,254
0,12
3,320
4,651
0,215
0,15
4,034
5,366
0,186
0,18
4,748
5,842
0,171
0,20
5,225

Coeficient de
transfer termic
unidirecional

[W/m2K]
0,584
0,406
0,337
0,289
0,237
0,201
0,183
0,625
0,438
0,366
0,313
0,258
0,219
0,200
0,605
0,422
0,352
0,301
0,248
0,211
0,191

g) Tabelul A.7. Acoperi - teras necirculabil


Alctuire acoperi:
Planeu din beton armat - 13 cm grosime
Barier vapori + strat difuzie
Strat de pant:
-din BCA GBN - T 15 cm grosime medie (varianta 1)
-din beton de pant 7,5 cm. Grosime medie (varianta 2)
Termoizolaie (tip i grosimi conform tabel)
Strat protecie termoizolaie ap slab armat 3 cm. grosime
Barier vapori
Hidroizolaie bituminoas: 2 straturi 7 mm. grosime
77

Strat lestare din pietri: 7 cm. Grosime


Varianta 1 strat pant din BCA
Grosime
strat
termoizolant

[m]
0,05
0,08
0,10
0,12
0,15
0,18
0,20
0,05
0,08
0,10
0,12
0,15
0,18
0,20
0,05
0,08
0,10
0,12
0,15
0,18
0,20

Rezisten
termic
specific
unidirecional

Coeficient de
transfer termic
unidirecional

Varianta 2 strat pant din beton de pant


Grosime
strat
termoizolant

Rezisten
termic
specific
unidirecional

[m2K/W]
[W/m2K]
[m]
[m2K/W]
Izolaie termic din plci din vat mineral
2,347
0,426
0,05
1,730
3,097
0,323
0,08
2,480
3,597
0,278
0,10
2,980
4,097
0,244
0,12
3,480
4,847
0,206
0,15
4,230
5,597
0,179
0,18
4,980
6,097
0,164
0,20
5,480
Izolaie termic din polistiren
2,233
0,448
0,05
1,616
2,915
0,343
0,08
2,298
3,370
0,297
0,10
2,752
3,824
0,261
0,12
3,207
4,506
0,222
0,15
3,889
5,188
0,193
0,18
4,571
5,642
0,177
0,20
5,025
Izolaie termic din poliuretan celular sau poliizocianat
2,287
0,437
0,05
1,670
3,002
0,333
0,08
2,384
3,478
0,287
0,10
2,861
3,954
0,253
0,12
3,337
4,668
0,214
0,15
4,051
5,383
0,186
0,18
4,765
5,859
0,171
0,20
5,242

Coeficient de
transfer termic
unidirecional

[W/m2K]
0,578
0,403
0,335
0,287
0,236
0,201
0,182
0,619
0,435
0,363
0,312
0,257
0,219
0,199
0,599
0,419
0,349
0,300
0,247
0,210
0,191

Note:
Valorile rezistenelor termice i ale transmitanelor termice din tabelele 17 sunt date pentru
sezonul rece;
Pentru sezonul cald, rezistenele termice din tabelele 17 se vor majora cu valoarea 0,042
W/(m2K);
Pentru lunile de var, pentru straturi de protecie termoreflectante de culoare aluminiu sau
alb, resistenele termice din tabelele 14 se pot majora cu valoarea
0,200 W/(m 2K)
2
2
[valoarea 0,200 W/(m K) include i majorarea de 0,042 W/(m K) corespunztoare sezonului
cald].

78

ANEXA 8
REFERINE TEHNICE I LEGISLATIVE
Nr.
Crt.
0
1.
2.
3.
4.
5.
6.
7.
Nr.
Crt.
0
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.

Acte legislative
1
Legea 50/1991 privind autorizarea lucrrilor de construcii
Ordinul ministrului transporturilor, construciilor i turismului i ministrului
administraiei i internelor nr.1822/394/2004, cu modificrile i completrile
ulterioare Regulament privind clasificarea i ncadrarea produselor pentru
construcii pe baza performanelor de comportare la foc
HG 28/2008 privind documentaia tehnico-economic
Ordin MLPAT nr.9/N/15.03.1993 Regulament privind protecia i igiena muncii n
construcii
Legea 319/2007 privind securitatea i sntatea n munc
Legea 307/2006 privind aprarea mpotriva incendiilor
HG 300/2006 privind cerinele minime de securitate si sntate pentru antierele
temporare sau mobile
Reglementri tehnice
1
Normativ privind proiectarea, execuia i exploatarea hidroizolaiilor la cldiri
Normativ de siguran la foc a construciilor
Norme generale de protecia muncii/2000, elaborate de Ministerul Muncii i
Proteciei Sociale n colaborare cu Ministerul Sntii
Normativ cadru de acordare i utilizare a echipamentului individual de protecia
muncii, aprobat cu Ordinul nr.225/1995
Normativ de prevenire i stingere a incendiilor pe durata executrii lucrrilor de
construcii i instalaii aferente acestora C300-1994
Norme generale de aprare mpotriva incendiilor nr.163-2007
P100-1/2006 Cod de proiectare seismic Partea I Prevederi de proiectare
pentru cldiri
P100-3/2008 Prevederi pentru evaluarea seismic a cldirilor existente
CR1-1-3-2005 Cod de proiectare. Evaluarea aciunii zpezii asupra construciilor
NP082-2004 Cod de proiectare. Bazele proiectrii i aciunii asupra construciilor.
Aciunea vntului
NP005-2003 Normativ privind proiectare construciilor din lemn
C125-2005 Normativ privind proiectarea i executarea msurilor de izolare fonic
i a tratamentelor acustice la cldiri
C107/0-2002 Normativ pentru proiectarea i execuia lucrrilor de izolaii termice
la cldiri
C107-2005 Ghid de evaluare a gradului de izolare termic a elementelor de
construcie ale cldirilor
GP.111-2004 Ghid de proiectare privind protecia mpotriva coroziunii a
construciilor din oel

Publicaia
2
MO nr.933/2004
MO nr.90/2005

MO nr.48/2008
MO nr.646/2006
MO nr.633/2006;
Ord.187/2010.
MO nr.252/2006

Publicaia
2
Ord.607/2003 MO
P.I bis 776/2003
P 118-O 27/N/1999
Ord.508 i 933/2002
MO nr.189/1995
Ord.20/N/1994
MO nr.216/2007
MOnr.803bis/2006
MOnr.647bis/2009
MOnr.198bis/2006
MO nr.349/2005;
MO nr.784/2005
MO nr.671/2003
MOnr.460 bis/1995
MO nr.1124bis/2005
MO nr.441bis/2005

79

Nr.
Crt.
0
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.

Standarde
1
SR EN 14964:2007 Substraturi rigide pentru nvelitoare de acoperi cu montare discontinu.
Definiii i caracteristici
SR EN 12056-3:2002 Reele de evacuare gravitaional din interiorul cldirilor. Partea 3:
Sistem de evacuare a apelor meteorice, proiectare i calcule
SR EN 1991-1-1:2004 Eurocod 1: Aciuni asupra structurilor. Partea 1-1: Aciuni generale.
Greuti specifice, greuti proprii, ncrcri utile pentru cldiri
SR EN 1991-1-1:2004/AC:2009 i a SR EN 1991-1-1:2004/NA:2006 Eurocod 1: Aciuni
asupra structurilor. Partea 1-1: Aciuni generale. Greuti specifice, greuti proprii, ncrcri
din exploatare pentru construcii. Anex naional
SR ENV 1187:2003 (metod de ncercare a acoperiurilor la expunerea la foc exterior)
SR EN 13501-5+A1:2010 (clasificare la foc a produselor i elementelor de construcii, n baza
rezultatelor ncercrilor de expunere la foc exterior)
SR EN 15287-1+A1:2011 Couri de fum. Proiectare, instalare i punere n funciune a
courilor de fum. Partea 1: Couri de fum pentru aparate de nclzire neetane
SR EN 15287-2:2008 Couri de fum. Proiectare, instalare i punere n funciune a courilor
de fum. Partea 2: Couri de fum pentru aparate de nclzire etane
SR EN 516:2006 Accesorii prefabricate pentru nvelitori de acoperi. Instalaii pentru acces
pe acoperi. Pasarele, podine, trepte
SR EN 517:2006 Accesorii prefabricate pentru nvelitoare de acoperi. Crlige de siguran