You are on page 1of 27

(HYUN TRADE Co.

)
4 576-1
Tel : 031)981-2654

H.P : 011-9121-9872

E-mail : hyuntrade@kornet.net

1.

( )
( ) .

2.

1)

( ) ,

( ) ,

( (DAC ) )

2)

( ) ( ) ,

3.
1)

( ),

2)

1)

( Size )

4.

1) ()

2)

STB-A1

STB-G

IIW Block
Type 1 & 2

(KS & JIS )


STB-A1

STB-G

5.
Pulse Generator

CRT

Stopwatch

Amplifier

CRT

Monitoring

CRT Monitoring

6.

7. (Calibration)

1)


Delay

2)



8.

1)
2)

( )
= Delay

3)

( )

= Zero Shift (Zero Offset)

Delay

Delay

9.
1) CRT

# #
:
:
Screen
) 50 mm,
( = Range)

200 mm,

100 mm,

125 mm,

250 mm

...

2)

) STB-A1 25mm or 100mm

2) 1
1

Screen .
B1
B2
B3
B4

- Delay

B1 Echo 0 .

B1

**

**

B2
B3

B4
B5

10

1) B2, B3

-
B1
B2

**

**

B3
B4

B2, B3, B4 B5
B5

B1
.

3 Echo

- 3, 4

.
Range B1, B2, B3, B4
Delay
.
11

( 1)
10 = Scale factor
(Calibration Block X n) Scale factor = Position
: Scale factor : 1
Position : Cal. Block CRT
n : Cal. Block

( 2)
10 100% CRT %

.
, 6 (DE) 6
60%, 125mm ?
125mm X 0,6 (60%) = 75mm

12

0 B1 Echo 6) B2 Echo

- Delay
) Echo .

B1
B2

) (Range) 100mm

B3
B4

B1, B2, B3, B4


(Delay)
.
13

3) 2


Echo .

Screen .

B1 B2 .

2 .

- Gate

STB-A1 25mm


B1

B2
B3
B4

25mm

14

0 B1

- Gate

B1
B2
B3
B4

4 .

25mm



15

4) 1

DAC

* *
STB-G


16

4) 2

80%

80% dB
Gain Control

1 dB dB dB
()= Reference Level

Scanning dB
= Scanning Level

17

10.

IP

Range
B1

= Back Wall Echo

B

B1, B2, B3

18

19

20


()

()

)

.
( )

21

11. (dB)
=>
V(dB) = 20 log10A
A :
V : A

) 40dB
40 = 20 log10A
log10A = 2
A = 102 = 100()

) 14dB
14 = 20 log10A
log10A = 0.7
A = 100.7 5()

) 20dB
20 = 20 log10A
log10A = 1
A = 10()

) 6dB
6 = 20 log10A
log10A = 0.3
A = 100.3 2()

) 2dB
2 = 20 log10A
log10A = 0.1
A = 100.1 1.26()

) 0dB
0 = 20 log10A
A = 1()

) 1dB
1 = 20 log10A
log10A = 0.05
A = 100.05 1.12()
22

dB

V = 20 log(

h1 :
h2 :

) B1 : 80%, B2 : 40%
B2
V = 20 log(
)

) 6dB

BF : 50% ()

, 6, B2
40% 80% .

F : 10% ()
BF
V = 20 log (

) = 20 log

= -14dB

14dB.
14dB

23

12.

24

25

26

27