DGPEC022912a
1097.39m; 5.59h

Diamond Wrap Contact

Owner Contact

PEC CIA LTD.

Company

REPSOL

Joel Gualberto Bernal Clavijo/Engineer

Name

DAVID BALDEON

Manuel Maria Hidalgo S/N yvia interocenica KM 26

Address

Quito Ecuador
joel.bernal@pec-ecuador.com

City, Zip, Country


Email

593-3-2380 658

Phone
Fax
= User Input
= Material Properties

Desired Pressure =

380 psi

Operating Temp. =

201 F

Temp. Derating Factor: T =

Number of
Plies =

0.333

Poisson's Ratio: =

Enter number of plies until pressure


rating is satisfied.

0.196

E ac =

CB

Enter cloth types: AA, BA, CA, CB,


or HY

0.6

Service Factor: =

Modulus:

Material
Used:

4,223,486 psi

Epoxy type:

High Temp. Amb.

Repair Thickness: t min =

0.09 in

OD of Pipe, D =

16.000 in

Diameter of Defect, d =

0.25 in

Nominal Pipe Wall, t =


Composite Modulus in Axial
Direction Ea =

0.375 in
3,051,498 psi

1,000 psi

Shear Modulus: G =

88,780 psi

Toughness Parameter, =

2
2.5 in.-lb/in

Allowable Axial Strain in


Composite a =

Lap Shear Strength ,

0.01297

"
%
$
'
$
'
! LCL
ASME PCC2 Equation (13): P = fT f $
2
"
%
1!
"
) $ 3 d 4 + 1 d ' + 3 d 2 ''
$(
$ E
3
! & 64Gtmin '&
# 512tmin
#
ac
P=
Equation (17):

504.6 psi

!
$
E!t
Lover = max # 2.5 Dt / 2, a a repair &
"
"
%
L over =

Is # of Plies Acceptable?

4.90 in

2.5 Dt / 2 =

4.9003

Ea! atrepair
=
"

3.5624

Yes

4
plies of material and should extend a minimum of
4.90 inches from the defect on all sides.

This repair requires

Repair Recommendations:
(1) DW-HP-XM-1604HTA

(16 inch DiamondWrap HP 4-ply High Temperature Ambient 1 meter wide kit)

Installation Instructions: Wrap with 100% overlap for complete 4-ply repair. This kit will provide 1 meter of repair length and hold up to a .25
inch diameter through-wall defect no closer than 5 inches from the edge of the repair.
Note: The leak must be stopped prior to the installation of this repair kit. A warranty cannot be offered for components suffering from internal