[KHAN_PSDC_KNOW HOW] January 29, 2010

HEAT EXCHANGER DESIGN IN HYSYS


ENVIRONMENT

Dear PSDC member I would like to share my experience of heat exchanger


design in hysys. Being a member of PSDC you must have good hysys skill
for carry out your future research and the lab assignment given to you. First
of all start using hysys with the manual as it will make you familiar with the
basic terminology and the operations you can carry out in hysys. Then after
quickly following the basic, start doing example provided in the manual and
tries to do as much as you can to gain enough confidence before delving into
the details of the assignments.

Now you have basic idea about hysys and you are particularly concerns
about the design of heat exchanger so before designing you usually have
some idea about heat exchanger from thermodynamic point of view like:

 How much heat you can transfer from hot stream to cold stream
calculated by first law of thermodynamic (energy can neither be
created nor destroyed it just transform).
 Also you should know the direction of heat transfer as stated by
second law of thermodynamics heat can flow only from higher temp to
lower temp.
 Maximum allowable pressure drop from one or both stream (depends
on specific application) like that.
[KHAN_PSDC_KNOW HOW] January 29, 2010

There are so many things that you should know but these are just some
stating points now we will move to the more specific problems which a
newcomer usually encounters with:

OVERSPECIFIED

After you specify all the details of inlet and outlet stream your heat
exchanger is not converged means it is still yellow in color and show
error “over specified” it means you have either input extra values
and there is no room for hysys to calculate heat duty, UA and other
things so you need to remove some specified values like temp,
pressure, & vapor fraction and leave some job for Hysys engine to
perform the task for you, so as soon as you delete some values hysys
perform calculation and according to condition it will calculate the
required value and converged.
[KHAN_PSDC_KNOW HOW] January 29, 2010

UNDERSPECIFIED

This error means your streams on the basis of which hysys will perform
calculation is not fully define so you need to specify the required value
like temp, pressure, mole or mass flow rate & vapor fraction. There
are many ways you can do this the most easy and convenient way is to
open the worksheet under the condition menu of Heat exchanger and
you can see all streams at once and specify the required value there
and then your heat exchanger will be fixed.
[KHAN_PSDC_KNOW HOW] January 29, 2010

FRICTION FACTOR LOW & TEMPERATURE CROSSING

This is the most annoying thing which I have faced it happens just
because of thermodynamic violation, the available heat which we have
in hot stream we can only transfer that amount to the cold stream
beyond which we cannot transfer. Temperature crossing happens when
the cold side is being heated to a temperature that is above the inlet
temperature of the hot side.
[KHAN_PSDC_KNOW HOW] January 29, 2010
[KHAN_PSDC_KNOW HOW] January 29, 2010

The remedy for this problem is try to increase the flow rate of hot or

cold stream to reach the minimum duty of heat required for the

particular operation and if you have freedom to change the

temperature try to adjust the temperature to avoid the thermodynamic

violations.

I hope these tips will fix your problem if you still have problem you can

ask senior guys them will help you to sort out your problem.

Comments & Suggestions