INFORME DE INSPECCION CON PARTICULAS MAGNETICAS

(MAGNETIC PARTICLE INSPECTION INFORM)


INFORME :

MT 94/2010

FECHA DE EXAMINACION:

(INFORM)

1 de marzo de 2010

HOJA:

(EXAMINATION DATE)

1 DE 1

(PAGE)

CLIENTE :
(CUSTOMER)

BIRLOS ROSCADOS 2" x 152,4 mm

IDENTIFICACION ITEM :
(ITEM IDENTIFICATION)

ASTM A 193 Gr. B7M

MATERIAL ITEM:
EQUIPO DE PRUEBA:

----------------------

ESPESOR DEL ITEM:

(ITEM MATERIAL )

(ITEM THICKNESS)

BOBINA MAGNAFLUX L - 10

PROCEDIMIENTO Y REVISION:

ALTERNA

CORRIENTE DE MAGNETIZACION:

(TEST EQUIPMENT)

(MAGNETIZATION CURRENT)

MT - 10 REV 04

ESTANDAR DE ACEPTACION : ASTM E - 709

(PROCEDURE)

(ACCEPTANCE STANDARD)

PARTICULAS MAGNETICAS:
(MAGNETIC PARTICLE TYPE)

VISIBLE
(VISIBLE)

FLUORESCENTE OK
(FLUORESCENT)

EQUIPO DE ILUMINACION: LAMP BLACK LIGHT BRAND: SPECTROLINE

SECAS
(DRY)

MODEL: B1B150B

HUMEDAS OK
(WET)

S/N 491853

WAVELENGHT 365 nm

(LIGHTING EQUIPMENT)

RESULTADO DE LA INSPECCION
(INSPECTION RESULT )
ITEMS INSPECCIONADOS

INDICACIONES

EVALUACION

( INSPECTED ITEMS)

(INDICATIONS)

(EVALUATION)

LOTE: AMO
PIEZA 1 A LA 5

SIN INDICACIONES

ACEPTADAS

MAPEO O REGISTRO DE LAS INDICACIONES :


(MAP OR RECORD OF INDICATIONS)

OBSERVACIONES :
(REMARKS)

EXAMINADO POR :
(EXAMINATED BY)
Alcance de la acreditacion: ASME V ARTICLE 2, ASTM E-8 Y ASTM E-797

NIVEL:
(LEVEL)

II