aneraore Eaypt
EGYPT eackt0 seismicnesion cove index) 18: wntry Index!
Code Name Regulations for Earthquakes-Resistant Design of Buildings in Egypt
Issued by -
Revision -
Horizontal Base Shear V= C,W,
where C, is the seismic design coefficient and W is the total seismic
weight. A PROCEDURE” for evaluating each of these quantities is
given in the sections that follow.
Seismic design coefficient C,
‘The seismic design coefficient C, shall be determined from the following
formu:
Z = seismic ZONING factor
I= importance factor
'S = structural system type factor
M= material factor
R= tisk factor
Q = construction quality factor
C,= shall not be taken as greater than 4.8%ZIMQ, nor less than 0.02 for
sites with seismic ZONE® factors greater than zero.
Seismic ZONING “ factor Z
The seismic ZONING ® factor Z is given by
Z= ACF
A= standard value for horizontal acceleration ratio (expressed as
faction of the acceleration of gravity g) to be determined from Table |
and the seismic ZONING” map shown in Fig. 1
F = foundation soil factor to be determined from Fig, 2
Importance Factor I
Values for the importance factor I are given in Table 14.3, as fimetions of
buildings use.
Structural system-type factor S
hitpisee enten go|pine¥seismc_design_codelegyeegyothimét orranean Eat
‘Values for the structural system-type factor S must be determined
separately for each direction of the building. Unless more precise values
are determined, the recommended values for this factor that are given in
Table 2 may be used.
ipliisee beter gojpneliseismic_ design codelenypuegyet hint