You are on page 1of 6

RO DOSING PUMP DATA:

1. PRE-CHLORINATION CHEMICAL DOSING PUMP (Model: CDS44-2)


POSITION

AT THE ENTRY OF RAW WATER STORAGE TANK

SERIE
S

DATE/SERIAL

KOPKIT

VOLTS

AMPS

Hz

PHAS
E

NOMINAL OUTPUT

MAX PRESSURE

ITEM No.

A Plus

08/11.297408

K4VHC
H

230

0.2

50/6
0

48 GPD 7.6 LPH

50 PSI , 3.3 BAR

LBC4SB-VHCH-XXX

2. POST PH ADJUSTMENT CHEMICAL DOSING PUMP (Model: CDSS6 )


POSITION

AT THE FRONT OF RO MEMBRANE

SERIE
S

DATE/SERIAL

KOPKIT

VOLTS

AMPS

Hz

PHAS
E

NOMINAL OUTPUT

MAX PRESSURE

ITEM No.

A Plus

08/11.297411

K2PHC1

230

0.2

50/6
0

6 GPD 0.9 LPH

150 PSI , 10 BAR

LB02SB-PHC1-XXX

3. ANTISCALANT DOSING PUMP (Model: CDS30)


POSITION

AT THE FRONT OF RO MEMBRANE

SERIE
S

DATE/SERIAL

KOPKIT

VOLTS

AMPS

Hz

PHAS
E

NOMINAL OUTPUT

MAX PRESSURE

ITEM No.

A Plus

08/11.297432

K4VHC1

230

0.30

50/6
0

30 GPD 4.7 LPH

100 PSI , 7 BAR

LB64SB-VHC1-XXX

4. DECHLORINATION DOSING SYSTEM (Model: CDS24-ORP)


POSITION

AT THE FRONT OF RO MEMBRANE

SERIE
S

DATE/SERIAL

KOPKIT

VOLTS

AMPS

Hz

PHAS
E

NOMINAL OUTPUT

MAX PRESSURE

ITEM No.

A Plus

01/11.243758

K4VTC1

230

0.2

50/6
0

24 GPD 3.8 LPH

100 PSI , 7 BAR

LB04S2-VTC1-CZXXX

RO VERTICAL PUMP/MOTOR:
1. FILTER FEED PUMPS (Quantity 02)
PURPOSE

Create necessary boost for the pre-filtration service flow

POSITION

At the front of raw water storage

PUMP PORTION
TYPE

MODEL

Hmax

P2

Pmax/tmax

DIRECTION

CRN45-2-2 A-G-G-E-KUBE

A91158905-P11130075

50 Hz

2919 min-1

45
m3/h

41.4 m

30.6 m

5.5
kW

16/120
bar/0C

CCW

MOTOR PORTION
PHASE

3 Phase

WEIGHT

43 kg

POWER

5.50 kW

IP

55

MODEL

MG132SC2-38FF265-H3

Th.Cl.

NO.

85U07417

P.C.

1111

SERIAL NO.

DE 7308 BE.2CS NDE6206.2Z.C3

PROTECTOR TYPE

PTC 1600C TP 211

IEC 60034
FREQUENCY

Connection

Voltage

I1/1

Imax

50 Hz

/Y

220-240/380-415

19.0/11.0 A

21.0/12.2 A

60 Hz

/Y

220-277/380-480

18.4-16.2/10.6-9.3 A

20.2-17.8/16.6-10.2 A

Rotation(n)
2920-2940
min-1
3510-3550
min-1

cos

Efficiency

0.87-0.82

IE3 89.2%

0.90-0.80

IE3 89.5%

2. FILTER BACKWASH PUMP (Quantity 02)


PURPOSE

Create necessary boost for the greensand filter backwash flow

POSITION

At the front of raw water storage

PUMP PORTION
TYPE

MODEL

CRN90-1 A-G-G-E-KUBE

A98047296-P11131487

50 Hz

R
2919 min1

Hmax

P2

Pmax/tmax

DIRECTION

90 m3/h

35.3 m

20.2 m

7.50
SkW

16/120
bar/0C

CCW

MOTOR PORTION
PHASE

3 Phase

WEIGHT

53 kg

POWER

7.50 kW

IP

55

MODEL

MG132SB2-38FF265-H3

Th.Cl.

NO.

85U07522

P.C.

1118

SERIAL NO.

DE 7308 BE.2CS NDE6206.2Z.C3

PROTECTOR TYPE

PTC 1600C TP 211

IEC 60034
FREQUENCY

Connection

Voltage

I1/1

Imax

50 Hz

/Y

220-240/380-415

25.0-24.2/14.4-14.0 A

27.5-26.5/15.8-15.4 A

60 Hz

/Y

220-277/380-480

24.6-20.8/14.2-12.0 A

27-22.8/15.6-13.2 A

Rotation(n)
2910-2920
min-1
3490-3530
min-1

cos

Efficiency

0.88-0.82

IE3 90.1%

0.90-0.82

IE3 89.5%IE3 90.2

3. HIGH PRESSURE PUMP (Quantity 01)


PURPOSE

Provide boost for most of the necessary water flow to feed RO membranes

POSITION

At the front of RO membranes

PUMP PORTION
TYPE

MODEL

CRN45-1 A-P-G-E-KUBE

A98045172-P11130440

50 Hz

R
2934 min1

Hmax

P2

Pmax/tmax

DIRECTION

45 m3/h

127.8 m

100.4 m

18.5 kW

16/120
bar/0C

CCW

MOTOR PORTION
PHASE

3 Phase

WEIGHT

113 kg

POWER

7.50 kW

IP

55

MODEL

MG160LB2-42FF300-H3

Th.Cl.

NO.

85U07528

P.C.

1120

SERIAL NO.

947 DE 7309 BE.2CS NDE6309.C4

PROTECTOR TYPE

PTC 1600C TP 211

GREASE

UNIREX N3

QUANTITY

13 g

Tamb

400C

INTERVAL

4500 h

Tamb

600C

INTERVAL

1100 h

IEC 60034
FREQUENCY

Connection

Voltage

I1/1

Imax

50 Hz

/Y

220-240/380-415

59.5-56.5/34.5-32.5 A

65.5-62.0/38-35.5

60 Hz

/Y

220-277/380-480

59.5-48.5/34.5-28.0 A

65.5-53.5/38.0-31.0 A

Rotation(n)
2940-2950
min-1
3520-3560
min-1

cos

Efficiency

0.89-0.85

IE3 92.4%

0.89-0.84

IE2 91.0%IE3 91.7%

4. CLEANING PUMP (Quantity 01)


PURPOSE

Circulate cleaning solution from cleaning tank to RO system membranes and


again back to cleaning tank

POSITION

At the front of cleaning tank

PUMP PORTION
TYPE

MODEL

CRN20-03 A-FGJ-G-E-HQQE

A96500395-P11130092

50 Hz

R
2917 min1

Hmax

P2

Pmax/tmax

DIRECTION

21 m3/h

43.9 m

34.6 m

4.0 kW

25/120
bar/0C

CCW

MOTOR PORTION
PHASE

3 Phase

WEIGHT

37 kg

POWER

4.0 kW

IP

55

MODEL

MG112MC2-28FT130-H3

Th.Cl.

NO.

85U05413

P.C.

1114

SERIAL NO.

DE 7306 BE.2CS NDE6206.2Z.C3

PROTECTOR TYPE

PTC 1600C TP 211

IEC 60034
FREQUENCY

Connection

Voltage

I1/1

Imax

50 Hz

/Y

220-240/380-415

13.6/7.90 A

15.0/8.70 A

60 Hz

/Y

220-277/380-480

13.6-11.8/7.80-6.80 A

14.8-13.0/8.60-7.50 A

Rotation(n)
2920-2940
min-1
3510-3540
min-1

cos

Efficiency

0.87

IE3 88.1%

0.91-0.82

IE3 88.5%

OVERHEAD TANK PUMP (Quantity 02)


POSITION

Under the overhead tank / In front of RO plant

PHASE

3 Phase

38.5 + 13 m

POWER

4.0 kW

Hmax

39 m

MODEL

CP 230B

Hmin

13 m

Tmax

900C

100 + 900 l/min

H.P.

5.5

50 Hz

S1

2900 min-1

I.CL.

IP

X5

CONNECTION

/Y

VOLTAGE/CURRENT

240V , 16.2A / 415V, 9.4A

You might also like