You are on page 1of 4

OTDR report

Job info

Job ID
Contractor
Customer
Test date

:
: BECRWETT
: SPCC
: 04/04/2015 (05:00:21 p.m. GMT-5:00)

Fiber ID
Location A
Cable mfr.
Subset ID

: Fiber001
: DB-001/292200
:
:

Span loss
Span length
Average loss

: 0.234 dB
: 0.1416 km
: 1.651 dB/km

Reason
Operator A
Operator B
File

:
: CAMESA
:
: Fiber001.trc

Cable info

Cable ID
Location B
Type
Color ID

:
: DCS-001/292200
:
:

Link measurements

Avg. splice loss


Max. splice loss
Span ORL

: --: --: <21.51 dB

OTDR trace

dB

30.00

25.00
1

20.00

15.00

10.00

5.00

0.00

200

Signature : _________________________
EXFO Inc.

400

600

800

1000

Date : 01/02/2015
Page 1 / 4

OTDR report
Events table
No.

Loc.
(km)

0.0000
0.0000
0.0026

0.1416

Event type
Merged Event
Fiber Section (0.1416 km)
Reflective Event
Fiber Section (0.1424 km)
Echo
Fiber Section (0.0131 km)
Echo

0.2840
0.2971

A
a
A to B distance
3-pt. reflectance
4-pt. Ev. loss

:
:
:
:
:

0.5004 km, 8.697 dB


0.2501 km, 10.206 dB
0.2502 km, 8.697 dB
*****
6.958 dB

Wavelength
Filename
Hardware
Serial number
Software
Range
IOR
RBS

:
:
:
:
:
:
:
:

1310 nm (SM-9m)
Fiber001.trc
FTB-7200D-12CD-23B-EI
728658
N/A
1.2500 km
1.467700
-79.44

Signature : _________________________
EXFO Inc.

Loss
(dB)

Refl.
(dB)

---

-39.8
-39.8
-49.1

0.234
--0.242
--0.022
---

Marker info

B
b
A to B ORL
A to B LSA att.

Test and cable setup

Acq. time
Pulse width
Helix factor
Splice loss threshold
Reflectance threshold
End-of-fiber threshold

Att.
(dB/km)

Cumul.
(dB)
0.000

1.651
>-23.4
1.700
-58.9
1.700
-48.9

:
:
:
:

0.7506 km, 0.000 dB


1.0008 km, 0.000 dB
64.72 dB
9.817 dB/km

:
:
:
:
:
:

15 s
10 ns
0.00 %
0.020 dB
-72.0 dB
3.000 dB

0.234
0.234
---------

Date : 01/02/2015
Page 2 / 4

OTDR report
Job info

Job ID
Contractor
Customer
Test date

:
: BECRWETT
: SPCC
: 04/04/2015 (05:00:40 p.m. GMT-5:00)

Fiber ID
Location A
Cable mfr.
Subset ID

: Fiber001
: DB-001/292200
:
:

Span loss
Span length
Average loss

: 0.212 dB
: 0.1416 km
: 1.500 dB/km

Reason
Operator A
Operator B
File

:
: CAMESA
:
: Fiber001.trc

Cable info

Cable ID
Location B
Type
Color ID

:
: DCS-001/292200
:
:

Link measurements

Avg. splice loss


Max. splice loss
Span ORL

: --: --: <21.09 dB

OTDR trace

dB

30.00

25.00
1

20.00

15.00

10.00

5.00

0.00

200

Signature : _________________________
EXFO Inc.

400

600

800

1000

Date : 01/02/2015
Page 3 / 4

OTDR report
Events table
No.

Loc.
(km)

0.0000
0.0000
0.0026

0.1416

Event type
Merged Event
Fiber Section (0.1416 km)
Reflective Event
Fiber Section (0.1425 km)
Echo
Fiber Section (0.0129 km)
Echo

0.2842
0.2971

A
a
A to B distance
3-pt. reflectance
4-pt. Ev. loss

:
:
:
:
:

0.5004 km, 7.582 dB


0.2501 km, 10.970 dB
0.2502 km, 0.211 dB
-71.8 dB
7.164 dB

Wavelength
Filename
Hardware
Serial number
Software
Range
IOR
RBS

:
:
:
:
:
:
:
:

1550 nm (SM-9m)
Fiber001.trc
FTB-7200D-12CD-23B-EI
728658
N/A
1.2500 km
1.468325
-81.87

Signature : _________________________
EXFO Inc.

Loss
(dB)

Refl.
(dB)

---

-41.7
-41.7
-50.7

0.212
--0.214
--0.019
---

Marker info

B
b
A to B ORL
A to B LSA att.

Test and cable setup

Acq. time
Pulse width
Helix factor
Splice loss threshold
Reflectance threshold
End-of-fiber threshold

Att.
(dB/km)

Cumul.
(dB)
0.000

1.500
>-22.9
1.500
-65.2
1.500
-53.0

:
:
:
:

0.7506 km, 7.371 dB


1.0008 km, 0.000 dB
*****
10.292 dB/km

:
:
:
:
:
:

15 s
10 ns
0.00 %
0.020 dB
-72.0 dB
3.000 dB

0.212
0.212
---------

Date : 01/02/2015
Page 4 / 4