You are on page 1of 1

PSV-BOHA

CALCULATION OF CONSTANT BACK PRESSURE

Tank DV-103 design pressure


Static Height
Sp.gravity (From Safsiz)
converting head to pressure
Super imposed back pressure
(Tank pressure+Static height)
Built up back pressure from Safsiz

0.28873
30
0.80797
10.49312
10.78185

psig
ft
psig
psig

0 psig

CALCULATION OF RATED FLOWRATE


Certified value (From Red book)
3.151 gpm/sq.rt.psid
Set Pressure
250 psig
Relieving pressure
Total back pressure
dp
sq.rt of dp

289.7 psia
25.47785 psia
264.2222
16.25491

Rated flow rate


1 gpm
51.217 gpm
Density (From Safsiz)

51.21923
8.020833
410.8209
50.44

Rated flow rate

gpm
ft3/hr
ft3/hr
lb/ft3

20721.8 lb/hr

MAXIMUM DISCHARGE PRESSURE CALCULATION


Total developed head of pump P-3
285 ft
Interms of pressure
99.68461 psig
Tank DV-3 design pressure
0.2526 psig
Staic Height, 40ft
13.99 psig
Maximum discharge pressure
113.9272 psig