CONNECTION:
CALCULATION
SST - ROOF TOP 20M HEIGHT
BTS Standard
CAC PROJECT 2005T
F 5
[
a
=
JWINOSIHOH) —2°0 t OE" L968. 68°9RL 00°966, 3i8uis, a 8
a er am a LF
[ — :
|" TWINOZRIOH ONDVEa
aa)
yeyediay (54) (34) (ay) (84) (84) weayS: (Cu)
SueWwoy ney (yssy) a u syewryng eyewynd mone nd _| ‘moje Suyreaq | “mony seays |aiqnop / ai8uis| slog so ep | al saquaw {e093 oN
S002 Pafe1s DvD - paepuers S4q ( dos Jooy ) BOT Bays WOT ISS + aurey yafosg |
L108 40 NOLLWINDW>PERHITUNGAN SEMUA JOINT FLANGE,
‘SST 20M Three Leg ( Roof Top ) BTS Standard - CAC Project 2005
1, Steel Bar (fy )= 2400 kg/em2
2. Maximum force at tower Base
Pmax = 494.703 kg
Tmax = 10978.21 kg
3. Requaired Area of Base Plate =
Used D- 20m
fveP/A 15.75 kg/em2
» tp = mxsqrt (fp/1.33x0.25xFy ) = 0.84 cm
Ti T/6 = 1829.70 kg
MeT.b = 10978.21 Kg.cm
fb= M/Z < 1.33x0.75xfy
» tp= sqrt ( 6xM/( 35x1.33x0.75xfy)= 0.89 cm
Used : Flange plate thick. 15 mm
5, Notation
Fv = Allowable bearing strength of thi
Tf = Applied uplift force per anchore bolt
tp = Required thickness of flange
M-= Bending Moment Tributary to coulomn by one bolt.
fb = Bending stress
Abuse = Total area of Base Plate
‘otal compression at tower base per one leg
T= Total Uplift at tower base per one leg
Distance from bolt center line to the face of coulmn,
m = Distance from bolt center line to the edges of FlangePERHITUNGAN BAUT UNTUK FLANGE
‘SST 20M Three Leg ( Roof Top ) BTS Standard - CAC Project 2005
1, Steel Bar ( fy )= 2400 kg/em2
2. Maximum force at tower Base
- 4944.70 kg
. 10978.21 kg
= 12.02 kg
3. Allowable tensile stress of anchore bolt = 16 mm,
Try: 4D 16 ( Stell Bar $S-400 )
A= 8.04 cm2
fv=S/A= — 0,001495044 t/em2. < Fvs0.3xfy=
Ft=0.6 x fy= 1.44 tiem?
Fts = 1.4 Ft- 1.6 fv = 2.01 t/em2 > Ft
Fts 2.01 t/em2
ft= 1.37 tema,
AV/Fy + ft/Ft= 0.95 < 1
4, Requaired embeded length of anchor Bolt
Le = 2*t flange + expand = 60 mm
Used D16 - 60 mm
5. Notation
fy = Yield strength of concrete
FV = Allowable bearing strength of the concrete
Ft = Allowable tensil stress of anchore bolt
Fts = Allowable tensile stress for bolts subject to combined tension and shear
Fey = Allowable bond stress of concrete
fv = actual shear stress of anchore bolt
ft = Actual tensil stress of anchore bolt
fc = Compressive strength of concrete
‘A= Total area of anchore bolt
P = Total compression at tower base per one leg
T = Total Uplift at tower base per one leg
S = Total Shear force at tower base per one leg
L = Required embeded length of anchore bolt in concrete
0.84 t/cm2PERHITUNGAN ANGKUR
SST 20M Three Leg ( Roof Top ) BTS Standard - CAC Project 2005
1, Steel Bar (fy )= 2400 kg/cm2
2. Maximum force at tower Base
P= 5916.48 kg
T= 13035.18 kg.
Ss 43.34 kg
3. Allowable tensile stress of anchore bolt = 20 mm
Try: 4D 20 ( Stell Bar $S-400 )
A= 12.56 cm2
fv=S/A= 0.003450873 t/cm2 < Fv=0.3xfy=
Ft= 0.6 x fy 1.44 t/em2
Fts=1.4Ft- 1.6 fv= 2.01 t/em2 > Ft
Fts =Ft 2.01 tema
ft= ws 1.04 t/em2
fv/Fv + ft/Ft = 0.73 < 1
4. Requaired embeded length of anchor Bolt
Fev = 0.53 sqrt fc’ = 7.01 kg/em2
Le =T/(Fevx8xPIxD ) 73.97 cm
Used 020-750 mm
5. Notation
fy = Yield strength of concrete
Fv = Allowable bearing strength of the concrete
Ft = Allowable tensil stress of anchore bolt
Fts = Allowable tensile stress for bolts subject to combined tension and shear
Fey = Allowable bond stress of concrete
fv = actual shear stress of anchore bolt
ft = Actual tensil stress of anchore bolt
fc’ = Compressive strength of concrete
A= Total area of anchore bolt
Total compression at tower base per one leg
T = Total Uplift at tower base per one leg
otal Shear force at tower base per one leg
Required embeded length of anchore bolt in concrete
0.72 t/em2.PERHITUNGAN COLUMN BASE PLATE
‘SST 20M Three Leg ( Roof Top ) BTS Standard - CAC Project 2005
1, Steel Bar ( fy )= 2400 kg/cm2
1, Concrete K-175 = 61.25 kg/em2 (0.35 fc’)
2. Maximum force at tower Base
5916.48 kg
13035.18 kg
43.34 kg
3. Requaired Area of Base Plate =
Requaired - 72.63 cm2
Requaired It ( AKAs )/Phi = 9.62 cm
Used D- 20cm
fv-P/A 18.84 kg/cm?
tp = mxsqrt (fp/1.33x0.25xFy ) = 1.23 cm
TWA4= 3258.80 kg
19552.77 Kg.cm
< 1.33x0.75xfy
tp= sqrt ( 6xM/ ( 40x1.33x0.75xfy)= 1.11. cm
Used : Base plate thick, 15 mm.
5. Notation
Fy = Yield strength of concrete
Fv = Allowable bearing strength of the concrete
Tf = Applied uplift force per anchore bolt
tp = Required thickness of base plate
Bending Moment Tributary to coulomn by one bolt
fb = Bending stress
fc’ = Compressive strength of concrete
Avase = Total area of Base Plate
‘otal compression at tower base per one leg
otal Uplift at tower base per one leg
Distance from bolt center line to the face of coulmn
Jobb
lp
m = Distance from bolt center line to the edges of Base plate