You are on page 1of 44

Table of Contents

Pin-Configuration Selection Guide for HDE, HDS, & EFP


Service Voltage Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical Service Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Ampacity Ratings by Contact Size . . . . . . . . . . . . . . . . . . . . . . . . . 5
Electrical Service Ratings Explained . . . . . . . . . . . . . . . . . . . . . . . 6
Operating Temperature Classification . . . . . . . . . . . . . . . . . . . . . . 7
Connector Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Insert Configuration Listing & Identification . . . . . . . . . . . . . . . . . 9
Connector Grounding Systems & Horsepower Ratings . . . . . . . . 10
1 Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-13
3 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-14
4 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-17
5 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-20
6 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21-23
7 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23-25
8 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-26
9 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
10 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-29
12, 14 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
15 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29-30
16, 17 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
18 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
19 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31-32
20, 21 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
22, 26 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
27 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-35
29 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
37 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-36
38 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
39, 42, 46 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
47 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37-38
50, 55 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
58, 60 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
61, 64, 68, 75 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
81, 90 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
100 Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41-42

Service Voltage Ratings: IEC & NEC


Contact/Wire Sizes in AWG & Metric (mm)
& Grounding Method Identification
Grounding Contact Termination Symbol

Pressure

Solder
Well

Crimp

Service Voltage Ratings


NEC Ratings

IEC Ratings
Symbol

DC Volts

instrumentation

AC Volts

Symbol

DC Volts

1000

1000

1000

1000

250 240

1250

1000

600 600

1750

1250

600 600

2450

1750

600 600

4200

3000

600 600

instrumentation

AC Volts

NOTE: IEC Service Voltage Ratings are not for circuit-breaking applications, frequency listing at 50, 60, and 400Hz

Contact Symbol/Wire Size


Multipin Contact Sizes
Contact
Symbols

Wire
Size

18
16
AWG AWG

12
AWG

10
AWG

8
AWG

4
AWG

1/0
AWG

4/0
AWG

350
MCM

Metric
(mm)

1.0
mm2

1.3
mm2

3.3
mm2

5.2
mm2

7.6
mm2

21
mm2

54
mm2

109
mm2

185
mm2

Single Pole Contact Sizes

Contact
Symbols

Wire
Size

4/0
AWG

262
MCM

313
MCM

373
MCM

444
MCM

500
MCM

535
MCM

646
MCM

777
MCM

1111
MCM

Metric
(mm)

109
mm2

132
mm2

159
mm2

189
mm2

227
mm2

240
mm2

273
mm2

326
mm2

394
mm2

562
mm2

Electrical Service Ratings

Insert Arrangement Service Rating - Table 1


Each insert plan form has a factory designated working voltage rating.
The voltage allowable through the contacts, male and female, is limited
by the dielectric separation between each contact and the nearest
conductor (adjacent contacts and the connector shell).
1

Electrical
Service
Voltage

Military Ratings
MIL-C-5015H
Specifications
Non-Circuit Breaking

A letter in Column 1 represents voltage ratings, with their associated


maximum values, both AC and DC. The insert plan form listings show
the ratings for each individual insert.

4
NEC Ratings

DC (V)

AC (V)

NonCircuit
Breaking
DC (V)

250

200

IEC
Service
Ratings

6
Required Minimum
Creepage Distance

Required Minimum
Clearance or
Through Air Spacing

Circuit
Breaking
AC (V)

DC (V)

AC (V)

in

mm

in

mm

1000

1000

1/16

700

500

250

240

1000

1000

1/8

1/16

1250

900

600

600

1250

1000

3/16

1/8

1750

1250

600

600

1750

1250

1/4

3/16

2450

1750

600

600

2450

1750

5/16

1/4

4200

3000

600

600

4200

3000

25

5/16

*I = Instrumentation
NEC, MS Values based on RMS using MIL-C-5015H Table, XVIII working voltage, IEC values based on 60664-1 table 3b.
IEC Service Ratings circuit breaking is not permissable in IEC standards without a hot disconnet permit.

Alternative Classifications of Current Rating


Military Current Ratings According to MIL-C-39029
The maximum current carrying capability of a contact pair is determined by the
basic design of the contacts and also the ability of the insulation to withstand the
temperature rises caused by an increase in current. The connector is rated up
to 125C (257F) for continuous operation. The actual working temperature is a
function of the ambient temperature and the summation of the heat dissipated
by each individual contact. The maximum current rating for continuous supply
is calculated from temperature of the insert. See Column 2 in the above table.
NEC (National Electrical Code) Non-Circuit Breaking Table 2, on the following
page, lists ratings that are based on test results of contacts and connectors.
The temperature range must fall within the range specified by Underwriters
Laboratories Inc., assuming certain wire sizes.
IEC Service Voltage Ratings Non-Circuit Breaking
Service voltage ratings as designated by IEC are derived from IEC 60664-1 Table
3b. When ascertaining required values for creepage and clearance voltages may
be increased by a factor of 1.1 to accommodate the range in common use. Table
2, on the following page, lists these ratings.

Ampacity Ratings by Contact Size (Gauge)


AWG, MCM, and mm2

Table 2: The following pages, 4 and 5, apply to table below.


1

Contact Sizes
#AWG MCM (mm)
18 AWG (1.0 mm)
16 AWG (1.3 mm)
12 AWG (3.3 mm)
10 AWG (5.2 mm)

Ampacity Rating
Non-Circuit Breaking
2

MS
-

NEC

NEC
Ampacity Rating
Non-Circuit Breaking

IEC
Ampacity Rating
Non-Circuit Breaking

Contact Resistance
Milliohms (mW)
Crimp Term

Solder Term

3.00

2.47

13

16

10

16

2.25

1.75

23

30

20

30

1.29

0.86

33

40

30

40

0.96

0.64

8 AWG (7.6 mm)


4 AWG (21 mm)

46

50

40

50

0.75

0.42

80

90

60

90

0.41

0.18

1/0 AWG (54 mm)


4/0 AWG (109 mm)

150

155

100

155

0.23

0.10

225

225

200

225

0.16

0.06

262 MCM (132 mm)


313 MCM (159 mm)

599

599

0.086

NA

636

636

0.090

NA

350 MCM (185 mm)


373 MCM (189 mm)

325

325

0.070

NA

674

674

0.070

NA

500 MCM (240 mm)


535 MCM (273 mm)

750

750

0.069

NA

898

898

0.032

NA

646 MCM (326 mm)


777 MCM (394 mm)

1009

1009

0.026

NA

1135

1135

0.020

NA

1111 MCM (562 mm)

1303

1303

0.017

NA

Electrical Service Ratings Explained

On previous page, see 'Table 2' header for notations:


states Assumptions and Standards:

Contact sizes: assume equal wire size included as contact

All ampacities shown are for individual contacts and must

and wire combination. Differing wire sizes will exhibit

be derated to determine maximum total current to be carried

different electrical performance results.

by the connector. Use the tables and formulas detailed on


pages: 6 and 7 Different ambient temperatures need to be

MS Specification (MIL-C-39029D) current ratings are in

taken into consideration when considering ampacity ratings,

accordance with MIL-C-39029D

depending on application and the intended location to be


used. It is particularly important to derate the connector when

NEC Specifications assume a wire size selection that is

being used in hazardous locations.

in accordance NEC guidelines for temperature rise.


4

NEC circuit breaking capability: connectors and

contacts that have demonstrated the ability to rupture


current under full rated load in accordance with UL
standard 1686, 1977 and MIL-C-22992E
4.1

NEC circuit breaking for hazardous locations

(Class and Division system) Connectors and contacts


have demonstrated the ability to disconnect under full
rated load in accordance with UL standard 1977, 1919
and CSA C22.2-159-M1987
5

IEC ampacity ratings: assume equal wire size,

included as contact and wire combination. Differing wire


sizes will exhibit different electrical performance results.
6

Contact Resistance when tested in accordance with

MIL-1344 method 3004.1 will not exceed the values listed


in table 1 column 6

Operating Temperature Classifications


in Ambient Temperatures

Table 2 IEC vs NEC


Temperature Classification
Wire current ratings:
For a more conservative standard use the hazardous location
derating formulas detailed on pages 6 and 7.

Classification
Temp in C
IEC

Hazardous locations:
The following standards IEC derating per:

IEC 60079-0 :2004 General requirements

IEC 60079-1 :2004 Flameproof protection 'd'

IEC 60079-7 :2003 Increased Safety protection 'e'
These standards require that equipment in an energized
condition does not exceed the rated surface temperature in
order not to ignite hazardous atmospheres. These values are
listed below in 'Table 3.'
The formulas detailed on pages 6 and 7 will be of assistance
to determine the correct insert and allowable ampacity for the
connector application and location the value is expressed as
dissipated wattage.

N. America

85

T6

T6

100

T5

T5

120

T4

T4A

135

T4

T4

150

T3

T3C

165

T3

T3B

180

T3

T3A

100

T3

T3

115

T2

T2D

130

T2

T2C

160

T2

T2B

180

T2

T2A

300

T2

T2

450

T1

T1

This table clarifies the differences in temperatures classification


between IEC and NEC, the North American Standard
NOTE:

Table 3 IEC Safe Equipment Operating Temperatures


Spontaneous
Ignition Temp
of the Gasses
(T)
85 < T < 100

100 < T < 135

135 < T < 200

200 < T < 300

Equipment Explosion Risk

300 < T < 450

Equipment Safe for Use

450 < T

Temperature Class of Equipment


T6
85C

T5
100C

T4
135C

T3
200C

T2
300C

T1
450C

Connector Selection Guide


Maximum Allowable Wattages & Contact Resistance Values

Table 1 - Maximum Allowable Dissipated Wattage

Connector
Shell Size

Upper Ambient Temperature of +40C

Upper Ambient Temperature of +50C

Temperature Class
T6

Upper Ambient Temperature of +65C

Temperature Class

T5

T6

Temperature Class

T5

T6

T5

12

23.8

31.7

17.0

24.3

10.7

18.7

16

39.6

52.8

30.2

43.2

14.6

25.6

20

52.1

69.4

37.2

53.1

17.1

29.8

24

64.3

85.1

47.0

67.1

24.1

42.1

28

79.5

106.1

57.3

81.8

29.8

52.2

Maximum Allowable Dissipated Wattage


NOTE: Please pay careful attention to the ambient temperature and also the temperature classification.

Connectors are marked T5 unless otherwise requested.

Table 2 - Contact Resistance Values

Contact Size

Contact Resistance
(milliohms mW)
Soldered

Crimped

Contact
Current
Rating
(amps)

Contact Size

Contact Resistance
(milliohms mW)
Soldered

Crimped

Contact
Current
Rating
(amps)

18 AWG (1.0mm)

2.47

3.00

262 MCM (132mm)

NA

0.086

599

16 AWG (1.3mm)

1.75

2.25

16

313 MCM (159mm)

NA

0.075

636

12 AWG (3.3mm)

0.86

1.29

30

350 MCM (185mm)

NA

0.070

725

10 AWG (5.2mm)

0.64

0.96

40

444 MCM (227mm)

NA

0.062

796

8 AWG (7.6mm)

0.42

0.75

50

535 MCM (273mm)

NA

0.032

898

4 AWG (21mm)

0.18

0.41

90

646 MCM (326mm)

NA

0.026

1009

1/0 AWG (54mm)

0.10

0.23

155

777 MCM (394mm)

NA

0.020

1135

4/0 AWG (109mm)

0.06

0.16

225

1111 MCM (562mm)

NA

0.017

1303

NOTE: Contact Resistance measured in accordance with MIL-Std 1344A, Method 3004.1
Contact Resistance value expressed in milliohms mW for Table 1 and Table 2.

IMPORTANT
To select the shell size of the connector, it is essential that you calculate
the dissipated wattage of the arrangement. This ensures that the
arrangement does not exceed the maximum permitted temperature
classification with regard to the upper ambient temperature for the
area of installation. In some cases it will be necessary to either derate
the allowed ampacity of each contact or increase the shell size of the
connector. Refer to Table 1 about the maximum allowable dissipated
wattage per connector size and use the calculations below to determine
safe and proper working temperature of the chosen electrical connector.

Insert Configuration Listing & Identification

HDE, HDS and EFP Electrical Connector


Service Rating

Figure 1
Contact Size
Symbol

The HDE, HDS and EFP Insert Configuration listing is used


primarily to identify various contact insert arrangements.
For the engineer, it provides visual selection of the insert
configuration needed to satisfy his other requirements. For
the end user, the list provides general information useful
in the termination of plugs and receptacles. To aid the
reader, the insert configuration are presented in numerical
order, based on the number of contacts in each insert.

10
15
9

14

Figure 1 - Illustration Configuration

02

11

16
4

12

8
7

Available
Alternate
Key
Positions

01

03

13
6

Contact
Location
Numbers

HDS and EFP Electrical Circuit Breaking CB Series.


Reversed Service Applications

The male insert illustration shown left (and those on the


following pages) is shown as it appears when viewed
from the front. Contacts are shown by both physical
position within the configuration and by contact number.
The contact number corresponds to the contact position
shown on the rear face of the insert illustrated as well
as to both the front and rear faces of the mating insert.
The symbol used to show contact location is indicative
of contact size. For example, the contact symbol in this
illustration represents a #16 (1.3mm) contact.

All contact inserts can be reversed in the field or


connectors can be ordered for reverse assembly.
Typically, the panel mount receptacle houses a female
insert, while the cable mounted plug accommodates the
male insert. In reverse service the opposite is the case.

An explanation of contact symbols is presented on each


page of the listing. Each drawing also provides data on
normal and alternate key positions. Drawings are reduced
from actual size of the insert configuration.

Standard Shell Female

NOTE: Alternate keying or insert polarization is intended to


prevent improper intermating of plugs and receptacles of
like shell sizes and like insert arrangements.

Standard Shell Male

Connector Grounding Systems & Horsepower Ratings

Equipment Chassis Grounding Layout


Equipment
Chasis

Load

Connector
Shells
Grounded

1/8
(3.18mm)

Common
to grid pin
Circuit
Ground

Line

Connector Shell Grounding

Non-Interrupting Ampere Rating

Equipment ground conductors, when used, are always


connected through a longer contact which is equipped
with a spring clip for mechanically connecting the
connector shell to the ground conductor. The ground Pin
(male) has 1/8" (3.18mm) additional length to mate first and
break last. The hard anodic coating is omitted inside shell
at points of contact for the ground clip to positively bond
to the connector shell. The position number of the long
contact with ground clip is given on the following contact
insert listing pages. No other positions are available.

When used in series with a disconnect switch, for


de-energizing the circuit before inserting or withdrawing
the plug, HDS Series CB Conecctors can be used for
loads up to the maximum ampere rating of the contacts.
Non-interrupting ratings are shown in the table below
as well as in the contact insert listings on the following
pages. If emergency circuit breaking, at these higher
ratings, is apt to be encountered, an automatic
disconnect switch should be used in series with the
connector. Information on the combination power and
automatic control contact inserts for HDS Series CB
Connectors can be supplied upon request.

Horsepower Ratings: Engergized Circuits

Rating of Motors: Maximum Horsepower

HDS Series CB Circuit breaking connectors are capable


of breaking circuits under load at their service voltage
and circuit breaking ampacity rating in accordance with
the new Standard UL 1686 and 1977, current rupturing
requirements. They can also be used in emergencies
to disconnect abnormal motor loads without danger of
injurious or damaging flashover even under locked-rotor
conditions. Maximum horsepower ratings at which they
can safely open the circuit in emergencies are shown in
the table at the right.In accordance with IEC regulations
circuits may not be ruptured under load.

Wires, Poles
& Phases

3-Wire,
4-Pole
Three Phase
3-Wire,
4-Pole
Two Phase
Three Wire
4-Wire,
4-Pole
Two Phase
Four Wire

10

Connector
Rating C
Breaking
Amperes

120V

240V

480V

600V

30

10

20

15

Classification

60

10

20

30

25

100

15

30

40

30

200

30

50

50

30

30

7.5

15

15

60

7.5

15

30

25

100

10

25

40

30

200

25

50

50

30

30

10

25

20

60

10

25

40

40

100

15

30

50

40

200

40

50

50

40

One Contact

Style
2

Term
Type

Shell
Size

Crimp

Quantity

C24

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-C24-14/0M

02 - 231

Socket

HDS-C24-14/0F

Size AWG/
MCM (mm)

Service
Voltage Rating

4/0 (109)

Style

Term
Type

Shell
Size

Crimp

C24

Insert
Gender

Part
Number

Pin

HDS-C24-1262M

Socket

HDS-C24-1262F

Size AWG/MCM (mm)

Service Voltage Rating

262MCM (132)

Term
Type

Shell
Size

Crimp

C24

Insert
Gender

Part
Number

Pin

HDS-C24-1262M

Socket

HDS-C24-1262F

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

313MCM (159)

Style

Term
Type

Shell
Size

Crimp

C24

Quantity

Style

01 - 100

Insert
Gender

Part
Number

Pin

HDS-C24-1373M

Socket

HDS-C24-1373F

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

373MCM (189)

N
N

N
N

11

One Contact

Style

Term
Type

Shell
Size

Crimp

C24

Insert
Gender

Part
Number

Pin

HDS-C24-1444M

Socket

HDS-C24-1444F

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

444MCM (227)

Style

Term
Type

Shell
Size

Crimp

C24

Insert
Gender

Part
Number

Pin

HDS-C24-1500M

Socket

HDS-C24-1500F

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

500MCM (240)

Style

Term
Type

Shell
Size

Crimp

C24

Insert
Gender

Part
Number

Pin

HDS-C24-1535M

Socket

HDS-C24-1535F

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

535MCM (273)

Style

Term
Type

Shell
Size

Crimp

C24

Insert
Gender

Part
Number

Pin

HDS-C24-1646M

Socket

HDS-C24-1646F

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

646MCM (326)

12

One Contact
Three Contacts

Style

Term
Type

Shell
Size

Crimp

C24

Insert
Gender

Part
Number

Pin

HDS-C24-1777M

Socket

HDS-C24-1777F

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

777MCM (394)

Style

Term
Type

Shell
Size

Crimp

C24

Insert
Gender

Part
Number

Pin

HDS-C24-11111M

Socket

HDS-C24-11111F

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

777MCM (394)

Style
2

Term
Type
Crimp

Shell
Size
12

Part
Number

Pin

HDS-12-312M

02 - 72

Socket

HDS-12-312F

03 - 108

Size AWG/MCM (mm)

Service Voltage Rating

12 (3.3)

Term
Type
Crimp

Shell
Size
12

Insert
Gender

Quantity

Style

Insert
Gender

Part
Number

Pin

HDS-12-310GM

Socket

HDS-12-310GF

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

10 (5.2)

Keyway Positions
01 - 36
N

01

04 - 144
05 - 180

02

03

3
04

05

Keyway Positions
01 - 50

N
1
3

13

01

Three Contacts

12

Part
Number

Keyway Positions

Pin

HDS-12-310M

02 - 100

Socket

HDS-12-310F

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

10 (5.2)

Term
Type

Style
2

Crimp

Shell
Size
12

Keyway Positions

Pin

HDS-12-38GM

02 - 140

Socket

HDS-12-38GF

03 - 180

Service Voltage Rating

8 (7.6)

Solder
Pressure

16
16

HDS-16-34GM1

02 - 90

Socket

HDS-16-34GF1

03 - 140

Pin

HDS-16-34GMR1

04 - 180

Socket

HDS-16-34GFR1

4 (21)

Term
Type

Solder

Pressure

Shell
Size
16
16

01 - 40

Part
Number

Keyway Positions

Pin

HDS-16-34M1

02 - 110

Socket

HDS-16-34F1

Pin

HDS-16-34MR1

Socket

HDS-16-34FR1

Size AWG/MCM (mm)

Service Voltage Rating

4 (21)

02

N
01
02

04

Insert
Gender

Quantity

01
2

03

Pin

1
3
04

Keyway Positions

Service Voltage Rating

04 - 220

Part
Number

Size AWG/MCM (mm)

Style

01 - 80

Insert
Gender

Quantity

02

Shell
Size

01

1
2

Part
Number

Size AWG/MCM (mm)

Term
Type

N
3

Insert
Gender

Quantity

Style

01 - 36

Crimp

Insert
Gender

03

01 - 70
N
3

01

Shell
Size

Term
Type

Style

14

02

Four Contacts

Term
Type

Style
2

Crimp

Shell
Size
12

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-12-416M

02 - 60

Socket

HDS-12-416F

03 - 90

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

16 (1.3)

Term
Type

Style
1

Solder

Crimp

Shell
Size
12
12

Pin

HDS-12-410M1

03 - 207

Socket

HDS-12-410F1

04 - 243

Pin

HDS-12-410M

Socket

HDS-12-410F
Service Voltage Rating

10 (5.2)

Term
Type

Solder

Crimp

Shell
Size
12
12

HDS-12-410GM1

03 - 207

Socket

HDS-12-410GF1

04 - 243

Pin

HDS-12-410GM

10 (5.2)

Term
Type

Solder

Quantity
4

Shell
Size
16

8 (7.6)

02 - 180
N
1
4G
04

Note: 01 key position


not available in
pressure termination

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-16-48M1

02 - 112

Socket

HDS-16-48F1

Size AWG/MCM (mm)

1
2

03

HDS-12-410GF

01

Note: 01 key position


not available in
pressure termination

Pin

Service Voltage Rating

Style

04

Keyway Positions

Size AWG/MCM (mm)

05

06

Part
Number

Quantity

03
04

01 - 27

Insert
Gender

Socket

02

06 - 180

Keyway Positions

01

05 - 150

Part
Number

Size AWG/MCM (mm)

N
1

04 - 120

Insert
Gender

Quantity

Style

01 - 30

2
3

03

02

01 - 45
N
01

1
2

Service Voltage Rating


4

02
3

15

Four Contacts

Term
Type

Style
1

Solder

Pressure

Crimp

Shell
Size
16
16
16

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-16-44M1

02 - 135

Socket

HDS-16-44F1

03 - 240

Pin

HDS-16-44MR1

04 - 255

Socket

HDS-16-44FR1

Pin

HDS-16-44M

Socket

HDS-16-44F

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

4 (21)

Term
Type

Style
1

Solder

Pressure

Crimp

Shell
Size
16
16
16

Pin

HDS-16-44GM1

02 - 120

Socket

HDS-16-44GF1

03 - 315

Pin

HDS-16-44GMR1

04 - 330

Socket

HDS-16-44GFR1

05 - 345

Pin

HDS-16-44GM

Socket

HDS-16-44GF
Service Voltage Rating

4 (21)

Term
Type

Shell
Size

Solder

C20

Pressure

C20

Crimp

C20

Part
Number

Keyway Positions

Pin

HDS-C20-41/0GM1

02 - 165

Socket

HDS-C20-41/0GF1

Pin

HDS-C20-41/0GMR1
HDS-C20-41/0GFR1

Pin

HDS-C20-41/0GM

Socket

HDS-C20-41/0GF

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

1/0 (54)

Term
Type

Style
1

Solder

Shell
Size
C20

Pressure

C20

Crimp

C20

Pin

HDS-C20-41/0M1

02 - 225

Socket

HDS-C20-41/0F1
HDS-C20-41/0FR1

Pin

HDS-C20-41/0M

Socket

HDS-C20-41/0F

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

1/0 (54)

01
4G

02

01

02

Keyway Positions

HDS-C20-41/0MR1

03

05

4G

Part
Number

Pin

04

01 - 15

Insert
Gender

Socket

02

01 - 105

Insert
Gender

Socket

01
3

03

Keyway Positions

Size AWG/MCM (mm)

1
4
2

Part
Number

04

Insert
Gender

Quantity

Style

01 - 105

01 - 15

01

Note: 01 key position


not available in
pressure termination

16

2
02

Four Contacts
Five Contacts

Style

Term
Type

Shell
Size

Solder

24

Insert
Gender

Part
Number

Pin

HDS-24-44/0M1

Socket

HDS-24-44/0F1

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

4/0 (109)

Keyway Positions

01 - 45
01

3
2

1
4

Style

Term
Type

Shell
Size

Solder

C24

Pressure

C24

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-C24-44/0GM1

02 - 165

Socket

HDS-C24-44/0GF1

Pin

HDS-C24-44/0GMR1

Socket

HDS-C24-44/0GFR1

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

4/0 (109)

01

01 - 15
1
2

4G
3

02

Style

Term
Type

Shell
Size

Solder

C24

Insert
Gender

Part
Number

Pin

HDS-C24-44/0CM1

02 - 225

Socket

HDS-C24-44/0CF1

03 - 240

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

4/0 (109)

Keyway Positions

01

01 - 15
4
3

03

02

Style

Term
Type

Shell
Size

Solder

12

Crimp

12

Insert
Gender

Part
Number

Pin

HDS-12-512M1

Socket

HDS-12-512F1

Pin

HDS-12-512M

Socket

HDS-12-512F

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

12 (3.3)

N
1
5

17

4G

Five Contacts

Solder

12

Crimp

12

Part
Number

Keyway Positions

Pin

HDS-12-512M1

02 - 97.3

Socket

HDS-12-512F1

Pin

HDS-12-512M

Socket

HDS-12-512MF

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

12 (3.3)

Term
Type

Style
1

Solder

Crimp

Shell
Size
16
16

Insert
Gender

Part
Number

Pin

HDS-16-58M1

Socket

HDS-16-58F1

Pin

HDS-16-58M

Socket

HDS-16-58F

01 - 48
N
01

Insert
Gender

Shell
Size

Term
Type

Style

02

Keyway Positions
01 - 36
N
01

2
4

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

8 (7.6)

Style

Term
Type

Shell
Size

Solder

16

Crimp

16

Insert
Gender

Part
Number

Pin

HDS-16-58GM1

Socket

HDS-16-58GF1

Pin

HDS-16-58GM

Socket

HDS-16-58GF

N
2
3
1
5

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

8 (7.6)

Style

Term
Type

Shell
Size

Solder

20

Pressure

20

Crimp

20

Insert
Gender

Part
Number

Pin

HDS-20-54GM1

Socket

HDS-20-54GF1

Pin

HDS-20-54GMR1

Socket

HDS-20-54GFR1

Pin

HDS-20-54GM

Socket

HDS-20-54GF

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

4 (21)

4G

Note: Contact cannot


be used with short
cable adapter 16

N
3

18

Five Contacts

Style

Term
Type

Shell
Size

Solder

20

Pressure

20

Insert
Gender

Part
Number

Pin

HDS-20-54GM1

Socket

HDS-20-54GF1

Pin

HDS-20-54GMR

Socket

HDS-20-54GFR

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

4 (21)

Style

Term
Type

Shell
Size

Solder

C24

Pressure

C24

Insert
Gender

Part
Number

Pin

HDS-C24-51/0M1

Socket

HDS-C24-51/0F1

Pin

HDS-C24-51/0MR1

Socket

HDS-C24-51/0FR1

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

1/0 (54)

Term
Type

Style

Shell
Size

Solder

C24

Pressure

C24

Insert
Gender

Part
Number

Pin

HDS-C24-51/0GM1

Socket

HDS-C24-51/0GF1

Pin

HDS-C24-51/0GMR1

Socket

HDS-C24-51/0GFR1

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

1/0 (54)

Term
Type

Shell
Size

Solder

C28

Style
1
1

Pressure

C28

Insert
Gender

Part
Number

Keyway Positions
1

Keyway Positions

01
4

Keyway Positions
01 - 36

01
1
5

4G

Keyway Positions

N
01

01 - 36
02 - 128

Pin

HDS-C28-54/0MR1

Socket

HDS-C28-54/0FR1

03 - 306

1/0 (109)

HDS-C28-54/0F1

01 - 108

HDS-C28-54/0M1

Service Voltage Rating

4G

Pin

Size AWG/MCM (mm)

01

Socket

Quantity

01 - 51

1
03
2
5

02

4
3

19

Five Contacts

Term
Type

Style
1

Solder

Pressure

Shell
Size
C28
C28

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-C28-54/0CGM1

02 - 126

Socket

HDS-C28-54/0CGF1

03 - 180

Pin

HDS-C28-54/0CGMR1

Socket

HDS-C28-54/0CGFR1

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

4/0 (109)

01 - 90

1
5
2
01

4G

02

3
03

Crimp

Part
Number

Keyway Positions

Pin

HDS-12-316CM

02 - 90

Socket

HDS-12-316CF

03 - 115

Size AWG/MCM (mm)

Service Voltage Rating

8 (7.6)

16 (1.3)

Term
Type

Style
1

Solder

Crimp

Shell
Size
20
20

01 - 45
N
5

04 - 180

05

05 - 270

01

02

Quantity

12

Insert
Gender

Shell
Size

Term
Type

Style

03

04

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-20-312CM1

02 - 110

Socket

HDS-20-312CF1

03 - 250

Pin

HDS-20-312CM

04 - 280

Socket

HDS-20-312CF

01 - 80

N
N
1

04

01

5
03

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

1/0 (54)

12 (3.3)

Term
Type

Style
1

Solder

Shell
Size
C24

02
3

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-C24-34/0CM1

02 - 157

Socket

HDS-C24-34/0CF1

03 - 292

N
N

01 - 45

01

03
5

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

4/0 (109)

12 (3.3)

02

20

Six Contacts

Term
Type

Style
2

Crimp

Shell
Size
20

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-20-412CM

02 - 45

Socket

HDS-20-412CF

03 - 68

8 (7.6)

12 (3.3)

Term
Type

Style
1

Pressure

Shell
Size
20

Pin

HDS-20-44CGMR1

02 - 120

Socket

HDS-20-44CGFR1
Service Voltage Rating

4 (21)

10 (5.2)

05
4

07 - 157

Keyway Positions

Size AWG/MCM (mm)

06 - 135

Part
Number

04

05 - 112

Insert
Gender

Quantity
2

04 - 90

N
01
1

03 - 180
05 - 270

4G

3
05

04

06
07

01 - 30

04 - 240

03

Service Voltage Rating

02
2

Size AWG/MCM (mm)

01

Quantity

01 - 23

02

03

Term
Type

Style
1

Solder

Crimp

Shell
Size
20
20

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-20-21/0CM1

02 - 244

Socket

HDS-20-21/0CF1

03 - 270

Pin

HDS-20-21/0CM

04 - 334

Socket

HDS-20-21/0CF

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

1/0 (54)

4 (21)

Style

Term
Type

Shell
Size

Solder

20

Crimp

Quantity

20

01 - 26

5
3
4

Keyway Positions
N

01 - 70

Pin

HDS-20-31/0CM1

02 - 145

Socket

HDS-20-31/0CF1

03 - 215

Pin

HDS-20-31/0CM

04 - 290

Socket

HDS-20-31/0CF

12 (3.3)

01

2
5

4
03

21

04

Service Voltage Rating

1/0 (54)

02

Part
Number

01
1

03

Insert
Gender

Size AWG/MCM (mm)

N
04

3
02

Six Contacts

Pressure

C24

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-C24-31/0CGMR1

02 - 120

Socket

HDS-C24-31/0CGFR1

Size AWG/MCM (mm)

Service Voltage Rating

1/0 (54)

10 Relay (5.2)

4 (21)

Style

Term
Type

Shell
Size

Solder

C24

01

03 - 180

4G

04 - 240

Quantity

01 - 30

Shell
Size

04

Term
Type

02

Style

03

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-C24-34/0CM1

02 - 145

Socket

HDS-C24-34/0CF1

03 - 215

01 - 70
6

01

04

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

4/0 (109)

12 (3.3)

04 - 290

3
4

02

03

C28

Part
Number

Keyway Positions

Pin

HDS-C28-61/0M

02 - 60

Socket

HDS-C28-61/0F

03 - 90

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

1/0 (54)

01 - 30

01
1
02

04 - 120

6
03

Crimp

Insert
Gender

05 - 230

Shell
Size

05

Term
Type

Style
1

Solder

Shell
Size
C28

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-C28-44/0CM1

02 - 126

Socket

HDS-C28-44/0CF1

03 - 252

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

4/0 (109)

12 Relay (3.3)

04

Term
Type

Style

01 - 90

1
6
5

01

03
4

02
3

22

Six Contacts
Seven Contacts

Term
Type

Style
1

Solder

Shell
Size
C28

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-C28-44/0CGM1

02 - 126

Socket

HDS-C28-44/0CGF1

01 - 90

1
6
5

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

4/0 (109)

12 Relay (3.3)

01

4G

02
3

Term
Type

Style
1

Solder

Shell
Size
C28

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-C28-4350CM1

02 - 120

Socket

HDS-C28-4350CF1

03 - 195

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

350MCM (185)

12 Relay (3.3)

01 - 60

1
5

01

2
4

02
6

03

Term
Type

Style
1

Pressure

Solder

Shell
Size
C28
C28

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-C28-44/0CGMR1

02 - 126

Socket

HDS-C28-44/0CGFR1

Pin

HDS-C28-44/0CGM1

Socket

HDS-C28-44/0CGF1

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

4/0 (109)

10 Relay (5.2)

01 - 90
1

03 - 180

02

03

Style
1

Term
Type
Crimp

Quantity
7

Shell
Size
12

Insert
Gender

Part
Number

Pin
Socket

Size AWG/MCM (mm)


350MCM (185)

01

4G

Keyway Positions
01 - 30

07 - 210

HDS-12-716M

02 - 60

08 - 240

HDS-12-716F

03 - 90

09 - 270

Service Voltage Rating


D

04 - 120

10 - 300

05 - 150

11 - 330

06 - 180

23

N
01

11
1

10
09
08

07

2
3

05

02
03
04

Seven Contacts

Shell
Size

Crimp

12

Insert
Gender

Part
Number

Pin

HDS-12-712GM

Socket

HDS-12-712GF

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

12 (3.3)

Style

Term
Type

Shell
Size

Crimp

12

Insert
Gender

Part
Number

Pin

HDS-12-712M

Socket

HDS-12-712F

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

12 (3.3)

Style
2

Term
Type
Crimp

Shell
Size
20

N
1

Pin

HDS-20-78M

02 - 72

07 - 252

Socket

HDS-20-78F

03 - 108

08 - 288

04 - 144

09 - 324

Keyway Positions

N
01

09
1

08

02

6
7

03

07

05 - 180

8 (7.6)

4
5

06 - 216

01 - 36

Service Voltage Rating

2
7
1

Part
Number

Size AWG/MCM (mm)

Insert
Gender

Quantity

Term
Type

04

Style

06
05

Style
2

Term
Type
Crimp

Shell
Size
24

Insert
Gender

Part
Number

Pin

HDS-24-74M

02 - 72

07 - 252

Socket

HDS-24-74F

03 - 108

08 - 288

04 - 144

09 - 324

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

8 (7.6)

Keyway Positions
01 - 36

05 - 180

06 - 216

N
09

08

07

02

03

06

24

01

05

04

Seven Contacts
Eight Contacts

Term
Type

Style
1

Solder

Crimp

Shell
Size
C24
C24

Insert
Gender

Part
Number

01 - 36

06 - 216

Pin

HDS-C24-71/0M1

02 - 72

07 - 252

Socket

HDS-C24-71/0F1

03 - 108

08 - 288

Pin

HDS-C24-71/0M

04 - 144

09 - 324

Socket

HDS-C24-71/0M

05 - 180

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

1/0 (54)

Term
Type

Style
1

Solder

Crimp

Shell
Size
24
24

Keyway Positions

N
09

01

08
5

02

03

07
3

06

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-24-41/0CM1

02 - 57

Socket

HDS-24-41/0CF1

03 - 105

Pin

HDS-24-41/0CM

04 - 147

Socket

HDS-24-41/0CF

05 - 200

04

05

01 - 22

01
8

02
2
1

3
03

Size AWG/MCM (mm)

Service Voltage Rating

1/0 (54)

4 (21)

Term
Type

Style
2

Crimp

Shell
Size
C24

Insert
Gender

4
04
05

Part
Number

Keyway Positions

01 - 30

Pin

HDS-C24-41/0CM

02 - 71

Socket

HDS-C24-41/0CF

03 - 108

01

02

Quantity

1/0 (54)

12 (3.3)

04 - 222

Service Voltage Rating

03

Size AWG/MCM (mm)

Quantity

04

Term
Type

Style
2

Solder

Quantity

Shell
Size
C28

Insert
Gender

Part
Number

Pin

HDS-C28-4350CM1

Socket

HDS-C28-4350CF1

Size AWG/MCM (mm)

Keyway Positions

01 - 60
1
N

Service Voltage Rating

350MCM (185)

12 (3.3)

2
4

6
3

25

01

Eight Contacts
Nine Contacts
Ten Contacts

C28

Part
Number

Pin

HDS-C28-4350CGM1

Socket

Size AWG/MCM (mm)

Service Voltage Rating

350MCM (185)

12 (3.3)

Term
Type
Crimp

Shell
Size
16

HDS-16-816CM

02 - 120

Socket

HDS-16-816CF

03 - 180

16 (1.3)

Crimp

Shell
Size
16

Keyway Positions

Pin

HDS-16-612CM

02 - 60

Socket

HDS-16-612CF

03 - 90

Service Voltage Rating

12 (3.3)

8 (7.6)

Term
Type
Crimp

Shell
Size
12

Insert
Gender

Part
Number

Pin

HDS-12-1016M

Socket

HDS-12-1016F

05

04

Size AWG/MCM (mm)

Service Voltage Rating

10

16 (1.3)

01

02

01 - 30
N

01
1
2

04 - 120

05 - 230

05

Keyway Positions
01 - 75
N
5

6
10

3
2

26

02

Quantity

03

Part
Number

Size AWG/MCM (mm)

04 - 240
05 - 300

Insert
Gender

Quantity

Style

01 - 60

4 (21)

01

4G

Pin

Keyway Positions

Service Voltage Rating

Part
Number

Size AWG/MCM (mm)

Term
Type

2
7

Insert
Gender

Quantity

Style

01 - 75

HDS-C28-4350CGF1

Quantity

Style

Keyway Positions

Solder

Insert
Gender

Shell
Size

Term
Type

Style

9
1

7
8

01

03
04

Ten Contacts

Term
Type

Style
2

Crimp

Shell
Size
12

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-12-1016GM

03 - 145

Socket

HDS-12-1016GF

02 - 70
N
1

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

10

16 (1.3)

Term
Type

Style

Crimp

16

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-16-612CM

02 - 45

Socket

HDS-16-612CF

03

01 - 30
N
01

12 (3.3)

Term
Type

Style
2

Crimp

Shell
Size
16

10 (5.2)

10

Service Voltage Rating

Size AWG/MCM (mm)

Quantity

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-16-612CGM

Socket

HDS-16-612CGF

01 - 35

Size AWG/MCM (mm)

Service Voltage Rating

10 (5.2)

4G

12 (3.3)

20

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-20-812CM1

02 - 60

Socket

HDS-20-812CF1

Size AWG/MCM (mm)

Service Voltage Rating

1/0 (54)

12 (3.3)

N
01
1

03 - 90
04 - 120

02

03

Quantity

01 - 30
8

Solder

10

Shell
Size

10

Term
Type

01
2

Quantity

Style

02

Shell
Size

10

02

9
7

04
4

27

Ten Contacts

Part
Number

Keyway Positions
01 - 30

Pin

HDS-20-612CM

02 - 45

Socket

HDS-20-612CF
Service Voltage Rating

4 (21)

12 (3.3)

02

10

Size AWG/MCM (mm)

01

Quantity

20

Insert
Gender

Crimp

Shell
Size

Term
Type

Style

Style
2

Term
Type
Crimp

Shell
Size
24

Insert
Gender

Part
Number

Pin

HDS-24-88CM

Socket

HDS-24-88CF

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

4 (21)

8 (7.6)

N
N
01

08
1
2

8
07

10
7

4
03

06

04

05

C24

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-C24-612CM

02 - 45

Socket

HDS-C24-612CF

1/0 (54)

12 (3.3)

02

10

Service Voltage Rating

01

Size AWG/MCM (mm)

N
N

Quantity

01 - 30

Crimp

Shell
Size

Term
Type

Style

Term
Type
Crimp

Shell
Size
C24

Insert
Gender

Part
Number

Pin

HDS-C24-612CGM

Socket

HDS-C24-612CGF

Style

Keyway Positions
01 - 35
N
N
01

6
1

1/0 (54)

12 (3.3)

10
4G

Service Voltage Rating

28

Size AWG/MCM (mm)

Quantity

02

Twelve Contacts
Fourteen Contacts
Fifteen Contacts

Crimp

Shell
Size
20

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-20-1210M

02 - 67

Socket

HDS-20-1210F

03 - 107

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

12

10 (5.2)

01 - 27
9

04 - 133

11

05 - 173
06 - 214

Keyway Positions

Pin

HDS-16-1216M

02 - 60

Socket

HDS-16-1216F

4 (21)

12

16 (1.3)

Term
Type

Style
1

Solder

Shell
Size
24

Part
Number

Pin

HDS-24-1016CM1

Socket

HDS-24-1016CF1

13

06 - 157

Size AWG/MCM (mm)

Service Voltage Rating

1/0 (54)

10

16 (1.3)

02

03

04
05

06

Keyway Positions

01

01 - 36

10

02 - 126

11

Quantity

04 - 112
05 - 135

Insert
Gender

03 - 90

12

Service Voltage Rating

01

Size AWG/MCM (mm)

10

Quantity

01 - 30

16

Part
Number

03

04

05

14

Crimp

Insert
Gender

11

Shell
Size

12

02

Term
Type

10

06

Style

01

Term
Type

Style

12

15

13

14

02

5
6

Term
Type

Style
1

Solder

Quantity

Shell
Size
24

Insert
Gender

Part
Number

Pin

HDS-24-1012CM1

Socket

HDS-24-1012CF1

Size AWG/MCM (mm)

Service Voltage Rating

1/0 (54)

10

12 (13.3)

Keyway Positions

N
N

01 - 36

01

1
10

11

12

15

4
13

14
8

29

5
6

Fifteen Contacts
Sixteen Contacts
Seventeen Contacts

Term
Type

Style
1

Solder

Shell
Size
C24

Insert
Gender

Part
Number

Pin

HDS-C24-1210CGM1

Socket

HDS-C24-1210CGF1

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

1/0 (54)

10

12 (3.3)

N
5

4
3

13

12

14
7

11

15

10

Style
2

Term
Type
Crimp

Quantity

Shell
Size
16

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-16-1616M

02 - 180

Socket

HDS-16-1616F

03 - 243

Size AWG/MCM (mm)

16

16 (1.3)

01 - 90

N
N
10

9
15

Service Voltage Rating

14

03

12

16
13

11

01

02

Term
Type
Crimp

Shell
Size
20

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-20-168M

02 - 57

Socket

01 - 36

HDS-20-168F

Quantity

Size AWG/MCM (mm)

Service Voltage Rating

16

8 (7.6)

N
1

10

03 - 90

15
9

13

02 - 72

06 - 234

HDS-12-1818F

03 - 108

07 - 270

18 (1.0)

08 - 306

07

14

06

05

30

17

04 - 144

01

Service Voltage Rating

1
13

15

Size AWG/MCM (mm)

12

Quantity

N
08
11

Socket

05 - 198

HDS-12-1718M

17

Pin

Keyway Positions
01 - 36

10

Part
Number

16

12

Insert
Gender

12

Crimp

Shell
Size

16

14

Term
Type

02

11

Style

01

Style

04

02
03

03

Eighteen Contacts
Nineteen Contacts

Keyway Positions

Pin

HDS-16-1616CM

02 - 90

Socket

HDS-16-1616CF

Crimp

Shell
Size
16

Insert
Gender

Part
Number

Pin

HDS-16-1912M

Socket

13
12

03

Keyway Positions
01 - 24

N
9

HDS-16-1912F
7

16

15

16

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-16-1912GM

03 - 144

Socket

HDS-16-1912GF

02 - 48
N

17

18

10

31

12 (3.3)

19

19

02

Service Voltage Rating

15

Size AWG/MCM (mm)

13

14

Quantity

12
11

Crimp

Shell
Size

16

Term
Type

Style

12

14

Service Voltage Rating

12 (3.3)

13

Size AWG/MCM (mm)

19

11

18

19

Quantity

01

10

17

Term
Type

04

Style

18

16 (1.3)

06 - 300

01
02

11

16

05 - 255

06

10

04 - 211

10 (5.2)

15

Service Voltage Rating

05

Size AWG/MCM (mm)

03 - 150

N
14

16

Quantity

01 - 60

Part
Number

16

Insert
Gender

17

Crimp

Shell
Size

Term
Type

Style

03

Nineteen Contacts

Part
Number

01 - 36

06 - 216

Pin

HDS-16-1916M

02 - 72

07 - 252

Socket

HDS-16-1916F

03 - 108

08 - 288

04 - 144

09 - 324

19

16 (1.3)

Service Voltage Rating

05 - 180

N
09
08
07

11
10

18

20

Insert
Gender

Part
Number

Pin

HDS-20-1912M

Socket

HDS-20-1912F

N
1

17

19

10

12 (3.3)

12 (3.3)

14

19

15

32

16

Service Voltage Rating

Size AWG/MCM (mm)

17

Quantity

HDS-20-1912GF

13

Socket

HDS-20-1912GM

Pin

Part
Number

12

20

Insert
Gender

18

Crimp

Shell
Size

19

Term
Type

Style

13

19

18

Service Voltage Rating

04

14

Size AWG/MCM (mm)

03

Quantity

05

12

Crimp

Shell
Size

02

11

Term
Type

15

16

06

Style

14

19

17

01

1
13

12

11

Size AWG/MCM (mm)

Keyway Positions

10

Quantity

16

Insert
Gender

16

Crimp

Shell
Size

15

Term
Type

Style

Twenty Contacts
Twenty-One Contacts

B Center / A Outer

10

Crimp

Shell
Size
20

Insert
Gender

Part
Number

Pin

HDS-20-2012GM

Socket

HDS-20-2012GF

Keyway Positions
01 - 56

N
4

17
1

20
16
15

Keyway Positions

Pin

HDS-20-1616CM

02 - 120

Socket

HDS-20-1616CF

03 - 180

15

14

13

20
10

01

02

2
17

12

8 (7.6)
16 (1.3)

05

4
16

05 - 300

16

Service Voltage Rating

N
N

Size AWG/MCM (mm)

01 - 60

Part
Number

18

Quantity

20

Insert
Gender

11

Crimp

Shell
Size

19

Term
Type

14

Style

11

13

B Center / A Outer

10

Service Voltage Rating

12 (3.3)

Size AWG/MCM (mm)

20

01

19

Quantity

18

Term
Type

Style

12 (3.3)

20

Service Voltage Rating

Size AWG/MCM (mm)

18

Quantity

17

20

01

16

19

HDS-20-2012F

15

HDS-20-2012M

Pin
Socket

01 - 43

14
13

20

Keyway Positions

12

Crimp

Part
Number

11

Insert
Gender

Shell
Size

12

Term
Type

Style

03

Keyway Positions

Pin

HDS-16-1116CM

02 - 90

Socket

HDS-16-1116CF

20

13

19

12
11

05

33

10

16 (1.3)

12 (3.3)

11

15
21

01

10

03 - 150
04 - 222

Service Voltage Rating

14

17

Size AWG/MCM (mm)

N
1

16

Quantity

01 - 30

Part
Number

16

Insert
Gender

18

Crimp

Shell
Size

Term
Type

Style

03

02

Twenty-Two Contacts
Twenty-Six Contacts
Twenty-Seven Contacts

Keyway Positions

Pin

HDS-20-2016CM

02 - 90

Socket

HDS-20-2016CF

14

18

22

02

21

12
11

10

E
D

8 (7.6)
16 (1.3)

01

17

Service Voltage Rating

20

15

13

03 - 191

N
16

Size AWG/MCM (mm)

01 - 45

19

Quantity

20

Part
Number

Crimp

Insert
Gender

20

Shell
Size

Term
Type

Style

03

18

18 (1.0)

Style

Crimp

Shell
Size
16

17

22
16

06

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-16-2416CM

02 - 90

Socket

HDS-16-2416CF

01 - 33
N
1

12

Keyway Positions

Pin

HDS-16-2416CGM

02 - 90

01 - 54
N
7

HDS-16-2416CGF

19

21

18

27
23
25

24

22

26

15

16

34

14

12 (3.3)

17

16 (1.3)

13

24

12

Service Voltage Rating

11

Size AWG/MCM (mm)

10

Quantity

01

20

9
4

Socket

27

24

14

13

11

Part
Number

10

16

Insert
Gender

Crimp

Shell
Size

23

Term
Type

22

Style

21

16 (1.3)

02

24

20

12 (3.3)

19

Service Voltage Rating

18

25

15

17

26

Size AWG/MCM (mm)

01

Quantity

03

04

05

16

Term
Type

26

21

16 (1.3)

07

13

05 - 180

02

19

Service Voltage Rating

12 (3.3)

23

Size AWG/MCM (mm)

01

20

Quantity

08

15

09 - 324

14

08 - 288

04 - 144

18

12

03 - 108

HDS-16-818CF1

N
09

07 - 252

02 - 72

06 - 216

HDS-16-818CM1

24

01 - 36

Pin
Socket

Keyway Positions

11

16

Part
Number

10

Solder

Insert
Gender

Shell
Size

25

Term
Type

Style

02

Twenty-Seven Contacts
Twenty-Nine Contacts
Thirty-Seven Contacts

Keyway Positions

Pin

HDS-20-2512CM

02 - 45

Socket

HDS-20-2512CF

03 - 90

Socket

HDS-C28-2312CF

03 - 90

D
A

16
13

12
29
28

8 (7.6)
12 (3.3)

04 - 135
05 - 155

2
23

02

01
3

25

1/0 (54)

23

22

26

Service Voltage Rating

04

05

24

21

02 - 66

03

01 - 45

HDS-C28-2312CM

Size AWG/MCM (mm)

22

Keyway Positions

Pin

Quantity

15
14

Part
Number

20

C28

06

19

Crimp

Insert
Gender

20
21

23

Shell
Size

19

26

27

02

17

Term
Type

06 - 225

18

05 - 150

18

25
24

11

01

4 (21)
12 (1.3)

Style

04 - 120

Service Voltage Rating

25

N
17

Size AWG/MCM (mm)

01 - 30

Quantity

20

Part
Number

10

Crimp

Insert
Gender

Shell
Size

Term
Type

Style

27

16

15

10

04

11

12

14

13

05

29

16

04

05

Part
Number

Pin

HDS-20-3712M

28

N
11

10

24

35

33

32
2

21
20

19

22
6

37

18

4
3

35

31

17

12 (3.3)

29

37

16

Service Voltage Rating

36

Size AWG/MCM (mm)

15

34

28

Quantity

13

14

HDS-20-3712F

26

27

Socket

12

25

Insert
Gender

23

20

03

Crimp

Shell
Size

36

15
14

06

Term
Type

02

30

16 (1.3)

11

07

10

HDS-16-3716M1

08

Pin

09 - 292

13

05 - 162

12

HDS-16-3716FC

37

20

32

04 - 130

Socket

31

01

HDS-16-3716MC

09

1
19

Pin

08 - 260

27

03 - 97

26

HDS-16-3716F

30

35

Socket

N
18

17

23

07 - 227

Socket
HDS-16-3716F1
Size AWG/MCM (mm)
Service Voltage Rating

37

Style

02 - 65

Quantity

16

HDS-16-3716M

22

Solder

06 - 195

Pin

33

16

Keyway Positions

21

Crimp

01 - 32

16

Part
Number

25

Crimp

Insert
Gender

34

Shell
Size

24

Term
Type

Style

03

Thirty-Seven Contacts
Thirty-Eight Contacts

17

18

36

28

15

35

27

14

13

12

Keyway Positions

Pin

HDS-24-3716M

02 - 45

01 - 15
17

16

36

28

14

27

13

26

12

25
11

03 - 127

15

36

14
13

26

05

03

25

34

12 (3.3)

35

1/0 (52)

04 - 178
05 - 254

02

2
35

37

Service Voltage Rating

30

22

Size AWG/MCM (mm)

20

29

31

Quantity

12
11

10

HDS-C24-3516CF1

19

28

27

01

Socket

16

24

02 - 76

01 - 25

33

HDS-C24-3516CM1

NN
18

17

23

Pin

10

Keyway Positions

C24

Part
Number

21

Solder

Insert
Gender

Shell
Size

03

Term
Type

Style

22

37

23

Service Voltage Rating

16 (1.3)

32

31

34

Size AWG/MCM (mm)

37

30

21

15

03 - 90

02
3

20

33

Quantity

2
19

29

HDS-24-3716F

01
1

18

32

Socket

24

Part
Number

35

Crimp

Insert
Gender

11

Shell
Size

Term
Type

02

Style

12 (3.3)

23

37

37

22

Service Voltage Rating

33

Size AWG/MCM (mm)

32

21

Quantity

3
20

31

29

16

HDS-20-3712GF

26

Socket

19

30

24

HDS-20-3712GM

N
N

02 - 100

10

Pin

Keyway Positions

25

20

Part
Number

Crimp

Insert
Gender

34

Shell
Size

24

Term
Type

Style

04

06 - 255

Socket

HDS-20-3516CF

03 - 90

07 - 283

04 - 117

08 - 315

31

18

30

38

17

16

29
13

14

15

28

12

36

27

05

02

06

34

03

16 (1.3)

22

33

25

10 (5.2)

3
35

01

21

32

24

Service Voltage Rating

19

35

Size AWG/MCM (mm)

07

20

11

02 - 60

08

26

HDS-20-3516CM

05 - 225

Pin

Quantity

Keyway Positions
01 - 27

23

Part
Number

10

20

Insert
Gender

37

Crimp

Shell
Size

Term
Type

36

Style

04

Thirty-Nine Contacts, Fourty-Two Contacts


Fourty-Six Contacts, Fourty-Seven Contacts

03 - 140

Pin

HDS-28-4212M

02 - 60

24

19
18

30

17
16

41

33

32

40

31

27

06 - 180

36

42

05 - 150
14

29

13

12

11

05

06

HDS-16-4516CF
20

02 - 60

43

10

05

46

06

37

02

31

06 - 180

42

4
28

05 - 150

01

27

8 (7.6)
16 (1.3)

04 - 120

22

26

25

41

44

2
45

30

Service Voltage Rating

03 - 90

23

40

HDS-20-4516CF

24

47

HDS-20-4516CM

Size AWG/MCM (mm)

10

01 - 30

37

Socket

30

Keyway Positions

36

Pin

Part
Number

29

11

12

28

31

32

27
42

13

26

29

Quantity

20

Insert
Gender

16

Crimp

Shell
Size

33
14

25

41

Term
Type

15

Style

15

21

39

8 (7.6)

46
43

34

38

18 (1.0)

35

16

17

45

17

45

44

18 36

20

Service Voltage Rating

19

Size AWG/MCM (mm)

1
24

40

39

19 37

18

Quantity

21
38

35

Socket

N
23

22

14

HDS-16-4516CM

34

Pin

13

16

12

Crimp

Part
Number

11

Insert
Gender

45

Shell
Size

33

Term
Type

32

Style

02

23
35

12 (3.3)

22

21
34

42

25

Service Voltage Rating

01

26

Size AWG/MCM (mm)

03 - 90
04 - 120

19

37

Quantity

N
N
20

01 - 30

HDS-28-4212F

03

Socket

15

14

13

Keyway Positions

18

28

Part
Number

17

Crimp

Insert
Gender

16

Shell
Size

15

Term
Type

30

Style

04

39

12

12 (3.3)

27

31

11

29

10 (5.2)

28

1/0 (54)

37

05 - 280

8 (7.6)

02

04 - 210

Service Voltage Rating

23

34

38

Size AWG/MCM (mm)

33

24

Quantity

05

22

10

HDS-C28-3112CF

21

28

Socket

01

32

31

38

02 - 80

20

26

HDS-C28-3112CM

01 - 40

10

Pin

NN

25

Keyway Positions

Part
Number

36

C28

Insert
Gender

39

Crimp

Shell
Size

Term
Type

35

Style

04

03

04

03

Fourty-Seven Contacts
Fifty Contacts
Fifty-Five Contacts

Term
Type

Style
1

Solder

Quantity

Shell
Size
C28

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-C28-4312CM1

02 - 120

Socket

HDS-C28-4312CF1

Size AWG/MCM (mm)

01 - 60

1/0 (54)

4 (21)

43

12 (3.3)

23
22

05

03 - 180

3
26

05 - 300

35

42

45

34

04

29

39

7
8

30

31

33

16

28

44

40
17

43

46

18

01

27
38

47
19

41

36

20

24

37

21

04 - 240

Service Voltage Rating

N
25

32
14

02

10

15

11

12

13

03

Part
Number

Keyway Positions

Pin

HDS-20-4616CM

02 - 60

HDS-16-5518M

02 - 60

07 - 220

Socket

HDS-16-5518F

Term
Type
Crimp

Shell
Size
28

Insert
Gender

Part
Number

Keyway Positions

Pin

HDS-28-4116CM

02 - 90

Socket

Size AWG/MCM (mm)

36 1
8

49

53

17

48

35

16

8 (7.6)

4 (21)

12 (3.3)

41

16 (1.3)

10

13

17

16

14

15
19
25

21

22
29

28

23

24

27

30

35
33

31

43
40
46

41
50

42

38

48

47
52

53

04

54

36
39

34

32

37

38

18

26

04

01

3
9

12

11

04 - 180

Service Voltage Rating

20

Quantity

03

N
N

01 - 30

HDS-28-4116CF

02

05

06

Style

07

40

51
55

47

34

33

15

08

54

27

10 - 345

39

50

23

09 - 285

37

01

22

Inst.

04 - 117
05 - 150

09

38

18 (1.0)

08 - 255

21

42 4
3

55

20

26

Service Voltage Rating

03 - 90

NN

10

41

Size AWG/MCM (mm)

04

25

Quantity

03

Keyway Positions

19

06 - 180

Pin

12

13

14

24

01 - 32

9
10

11

Part
Number

14

16

Insert
Gender

13

Crimp

Shell
Size

37

15

35

36

Term
Type

16

32

Style

05

12

38

7
8

33
34

39

17

32

49

11

16 (1.3)

31

40

18

02

29
30

10

46

06 - 315

48

41

19

28

50

42

01

47

43

20

05 - 225

46

45
44

46

21

04 - 150

1
27

31

8 (7.6)

22

25

24

23

03 - 120

Service Voltage Rating

06

45

Size AWG/MCM (mm)

HDS-20-4616CF

N
N
26

30

Socket

01 - 30

29

Quantity

20

Insert
Gender

52

Crimp

Shell
Size

44

Term
Type

28

Style

44

51
55

45
49

02

Fifty-Eight Contacts
Sixty Contacts

30

29

45

44

54

28
26

25

42

1
24

23

22

43

52
41

21

27

53

18

19

Service Voltage Rating

12 (3.3)

38

Size AWG/MCM (mm)

58

20

Quantity

40

HDS-24-5812F

17

Socket

58

24

49

Crimp

56

48

55

16

HDS-24-5812M

34

47

46

15

Pin

13

33

37

HDS-24-5812F1

12

32

31

36

Socket

9
8

11

10

35

HDS-24-5812M1

01 - 165

57

Pin

Keyway Positions

39

24

Part
Number

51

Solder

Insert
Gender

14

Shell
Size

50

Term
Type

Style

01

01 - 45

HDS-24-5812GM

24

23
41

40

51

20

39

57

50

19

38

56

16

15

10

22

50

36

59
58

51

38

52

21
20

16
24
23

58

39

51

38

57

49
48

47
13

20

56

36

35
15

14

22
21

50

46
34

11

12

37

35

15

37

33

19

18

34

14

13

16

19

18

32

17

06

39

43

60

04

54

59

42

16 (1.3)

52

12 (3.3)

05

53

45

7
53

05 - 270

40

29

31

Service Voltage Rating

28

41

01

55

Size AWG/MCM (mm)

03 - 150
04 - 210

26

25

27

44

Quantity

01 - 30

HDS-24-5316CF

03

30

Socket

12

49

02 - 90

11

48

33

HDS-24-5316CM

32

17

57

47

Pin

31

Keyway Positions

Part
Number

24

Insert
Gender

29

Crimp

Shell
Size

02

10

Term
Type

46

04

Style

55

60

05 - 270

54

05

27

43

04 - 210

26

42

53

30

39

01

25

45

16 (1.3)

03 - 150

41

40

28

60

23

56

Service Voltage Rating

N
1

24

44

Size AWG/MCM (mm)

14

HDS-20-6016F

Quantity

13

37

17

36

35

Socket

34

18

49

48

02 - 90

01 - 30

HDS-20-6016M

Pin

Keyway Positions

Part
Number

10

20

Insert
Gender

31

Crimp

Shell
Size

30

Term
Type

11

Style

29

58

55

Service Voltage Rating

12 (3.3)

44

53

45

Size AWG/MCM (mm)

58

27

43

52

01

26

54

Quantity

25

42

28

21

22

HDS-24-5812GF

Socket

Keyway Positions

12

Pin

Part
Number

33

24

Insert
Gender

32

Crimp

Shell
Size

47

Term
Type

46

Style

03

Sixty-One Contacts, Sixty-Four Contacts


Sixty-Eight Contacts, Seventy-Five Contacts

Pin

HDS-16-6118M

02 - 105

01 - 75

N
22

21
23
44

60

59

59

22
21

43

20

57

17

16

15

14

19

41

56

13

40

39

38

18

64

12

42

58
55

54
37

12

23

44

58

43

56

65

57

66

21

20

42

40

17

16

15

14

41

39

38

37

13

22

55

54

36

19

64

53

35

18

63
52

11
11

40

12

13

42
14

43

15

16

28

53

27
26

67
66

25

51

48

64

63
45

44

24

52

73

62

50

74

41

65

10

39

49

23

38

17

46
18

47
19

20

22

05

21

06

02

07

40

16 (1.3)

61

05 - 160

08

61

09 - 311

75

35

57

70

59

04 - 127

34

56

68

37

8 (7.6)
12 (3.3)

08 - 270

69

33

72

3
11

03 - 90

54

01

32

55

60

Service Voltage Rating

07 - 207

30

29

71

Size AWG/MCM (mm)

02 - 60

HDS-24-6116CF

09

31

36

HDS-24-6116CM

06 - 180

Pin
Socket

Keyway Positions
01 - 30

Part
Number

03

58

Quantity

24

Insert
Gender

10

Crimp

Shell
Size

68

34

Term
Type

61

67

02

33

04

Style

59

3
29

48

32

05 - 292

47

60

31

04 - 228

2
28

51

16 (1.3)

05

1
27

46

45

50

68

24

62

Service Voltage Rating

36

03 - 157

26

25

49

Size AWG/MCM (mm)

02 - 45

HDS-20-6816F

Quantity

11

Keyway Positions

30

Socket

63

HDS-20-6816M

Pin

Part
Number

20

Insert
Gender

02

Crimp

Shell
Size

01

10

Term
Type

62

03

Style

49

61

30

34

29

48

33

16 (1.3)

47

60

28

32

62

1
27

46

53

03 - 202

25
45

52

24

35

02 - 135

31

54

40

20

N
26

51

Service Voltage Rating

10 (5.2)

53

39

19

52

38

01 - 90

50

Size AWG/MCM (mm)

51

18

17

16

Keyway Positions

HDS-20-6216CF

Quantity

03

Socket

13

HDS-20-6216CM

37

Pin

15

Part
Number

36

20

Insert
Gender

14

Crimp

Shell
Size

35

Term
Type

50

Style

12

Inst.

11

18 (1.0)

58

61

34

Service Voltage Rating

10

Size AWG/MCM (mm)

02

Quantity

01

04

28

HDS-16-6118F3

56

61

Socket

55

48

04 - 232

31

HDS-16-6118M3

27
45

47

Pin

26
44

43

03 - 150

42 25

41

57

HDS-16-6118F

30

Socket

24

23

46

16

Keyway Positions

29

Crimp

Part
Number

16

Insert
Gender

49

Crimp

Shell
Size

33

Term
Type

32

Style

04

03

Eighty-One Contacts
Ninety Contacts
One-Hundred Contacts

74

81

18

42

41

61

17

40

60

36
13

12

11

39

73
57

35

34

10

59

80

33

16

72
56

58

71

70

38

79

37

7
8

55

15

02

29

31

14

27 28

52

05

07 - 300

51

06 - 270

65

76

50

64

75

01

24

48

26

18 (1.0)

62

23

47

67

12 (3.3)

63

77

11
70

05 - 225

46

66

Service Voltage Rating

06

1
22

45

44

49

Size AWG/MCM (mm)

03 - 135
04 - 180

43

HDS-20-7018CF

20

19

07

32

02 - 90

21

78

HDS-20-7018CM

Quantity

01 - 45

25

Socket

Keyway Positions

69

Pin

Part
Number

54

20

Insert
Gender

68

Crimp

Shell
Size

53

Term
Type

30

Style

03

04

11

13

41

14

15

27

70

50

89

82

26

49

25

20

19

18

17

48

68

81
88

16

45

44

43

24

69

65

64

42

67

80

79

78

47

87

66

10

12

39

63

23

22

46

02

37

61

38

21

01

36

60

05

75

06 - 270

84
90

59

73

58

18 (1.0)

05 - 225

72

83

33

56

35

90

06

71

32

55

85

Service Voltage Rating

04 - 180

2
31

54

74

Size AWG/MCM (mm)

03 - 130

1
53

52

34

HDS-20-9018F

28

77

02 - 90

30

29

62

HDS-20-9018M

Quantity

NN

01 - 54

57

Socket

Keyway Positions

40

Pin

Part
Number

86

20

Insert
Gender

Crimp

Shell
Size

Term
Type

76

Style

03

04

12

42

13

14

68

44
15

45
16

29

56
76

28

55

90

89
19

49

20

26

75
74

73

88

48

47

18

27

54

71

25

53

87
70

46

17

52

98

69

72

11

41

24

10

40

51

23

39

67

50

38

66

22

83

65

21

41

64

63

16 (1.3)

95

100

100

82

Service Voltage Rating

80
94

81

Size AWG/MCM (mm)

61

62

Quantity

93

99

35

60
79

92

91

34

59

78

77

33

43

HDS-24-10016F

1
58

57

37

Socket

31

30

97

HDS-24-10016M

86

Pin

N
32

85

Part
Number

96

24

Insert
Gender

Crimp

Shell
Size

36

Term
Type

84

Style

One-Hundred Contacts
One-Hundred Fourty-Three Contacts

37
61

36

80

60

79

59

92

78

93

35

34

33

32

58

77

31

30

57

27

26

29

71

66
68

N
N

13

51
14
52

15

17

54
18

10
55

19

56
20

8
11
7

35
34

68

132

116
115

131

33
32

94

31

66

95

114

23

93

141

22

67

96

130

58

59

65

13
57

21

89

88

30

87

11
2

11

64

14

86

11

12

128

110 111

85

14

139

127

91

50

16

92

12

29

49

63

11

80

10

82

28

10
48

81

12
5

10

62

47

79

143

78

105

90

27

104

60

24

61

26

10

12

13

46

121

135

01

5
44

76

134

101

53

100

4
43

75

84

42

83

120
19

74

13

97

73

99

98

2
41

69

1
40

72

71

70

12

36

39

38

37

10

01 - 46

25

42

13
14

15

137

10

11

12

42

43

44
16

124

16 (1.3)

41

46
45

40

67

123

143

39

86

69

3
10

Service Voltage Rating

38

65

85

87
70

47

84

Keyway Positions

HDS-28-14316F

Size AWG/MCM (mm)

37

64

96

97
88

48

63
83

89

20

36

95
98

72

49

HDS-28-14316M

Quantity

25

28
90

22

62
82

100

73

50

35

61
81

94

99

74

77

Socket

24

56

55

54

53

92
91

23

01
5

80

28

52

93

34

60

Crimp

23

76
75

4
33

59
79

45

Pin

3
32

58

77

53

25

Part
Number

2
31

78

54

17

Insert
Gender

22

76

26

18

Shell
Size

1
57

56
55

19

Term
Type

51

91
75

74

29

21

Style

73

50

16 (1.3)

18

83

17

21

12 (3.3)

20

17

30

28
27

52

Service Voltage Rating

19

01 - 60

51

Size AWG/MCM (mm)

48

Keyway Positions

24

Quantity

47

HDS-28-8316CF

46

Socket

16

HDS-28-8316CM

45

Pin

15

Part
Number

49

28

Insert
Gender

69

Crimp

Shell
Size

71

Term
Type

72

Style

70

13

68

16 (1.3)

87

100

100

97

Service Voltage Rating

84
96

86

Size AWG/MCM (mm)

95

94

85

Quantity

83

82

81

66

44

HDS-24-10016GF

12

42

65

67

Socket

11

41

64

63

62

10

40

39

38

99

HDS-24-10016GM

90

Pin

N
9

89

Part
Number

98

24

Insert
Gender

14

Crimp

Shell
Size

43

Term
Type

88

Style

Electrical Equipment Corp.


4050 North Rockwell Street
Chicago, Illinois
60618, USA

You might also like