Inspection Date:07-11-2015
Inspector
Trusted Home Inspections
Andrew Kotary
8242 Dexter pkwy
Baldwinsville, New York 13027
Phone:(315)572-5990
E-Mail:drew13151@gmail.com
ThankyouforchoosingTrustedHomeInspections.
Thisreportisdesignedtobeasthoroughaspossible,butalsoclearandconcise.
Ifyouhaveanyquestionspleasecallusat(315)572-5990
Table of Contents
General Information
Roof & Ventilation
Exterior Walls
Exterior Grounds
Attic
Main Bathroom
Basement Bathroom
Fireplace
General Interior
Kitchen
Laundry
Electrical System
Domestic Water Heater
Heating System
Air Conditioner
Plumbing System
Basement
Safety Concerns
Report Summary
Basement
07/11/2015
Nobalustersonhandrailatbasementsteps.Thisisasafetyhazardandmay
leadtoinjury.Recommendrepairbyaqualifiedcontractor.
Theventpipesforthefurnaceandwaterheaterareventedintothechimney.
Theproblemsisthattherearegapswherethepipesenterintothechimney.
07/11/2015
Thiscancausecarbonmonoxidetoenterbackintothebasement.Recommend
aqualifiedcontractorrepairasneeded.
Electrical System
Thehomeseemstohave60ampsforelectricalservice.Themaindisconnect
usesa100ampbreaker.Thisisaproblembecausethewiremayheatuptoo
07/14/2015
muchandpossiblycauseafirebeforethebreakertrips.Recommendcontacting
licensedelectriciantorepairasneeded.
07/14/2015
Ontherightsideoftheelectricalpanelthere'sanundersizedwire.Contacta
licensedelectriciantorepairasneeded.
Exterior Grounds
Walkwayisinacceptablecondition.Thereisonesectionthathassettledandis
nolongerlevel.Whichisaslip,trip,andfallhazard.Thissectionislocatedat
07/11/2015
thefrontofthehouseandrightnexttothedriveway.Recommendhavinga
qualifiedcontractorrepairasneeded.
Laundry
There'satwistinthedryerventline.Thiscancauselinttobecomecloggedin
07/11/2015 theline,whichcouldbecomeafirehazard.Recommendcontactingaqualified
contractortorepairasnecessary.
Safety Concerns
NoCOdetectorsandoldersmokedetectorswerenotedinhouseattimeof
07/11/2015 inspection.Thisisasafetyrisk.RecommendinstallationofnewsmokeandCO
detectors.
Basement Bathroom
BasementBathroomseemstobeanadditionfromalongtimeago,thiswasnot
07/11/2015 builttostandardbuildingpractices.Recommendcontactingaqualifiedplumber
tofurtherevaluateandrepairasneeded.
Attic
Noaccessdoorsorhatchwasfoundfortheattic.Theinspectorwasunableto
evaluatetheatticandinsidethekneewalls,anditisexcludedfromthis
inspection.Thepossibilityofproblemsdoesexist.Theremaybemold,flashing
07/11/2015
leaks,orinsulationissues.Recommendhavingaqualifiedcontractorinstall
accesshatchesasnecessaryandasperstandardbuildingpracticestoallowfor
periodicevaluationofatticspaces.
Basement
SumppumpisnotconnectedtoaGFIoutletandisalsopoweredwithan
SumppumpisnotconnectedtoaGFIoutletandisalsopoweredwithan
07/11/2015 extensioncord.Extensioncordsshouldn'tbeusedforpermanentwiring.
Recommendalicensedelectricianrepairasneeded.
Inthebasementthereisajunctionboxlocatedontheceilingnearthelaundry
area.Thisjunctionboxismissingitscover,alsoontheceilingbetweenthegas
meterandthewatermain,thereareafewwiresstickingoutfromtheceiling
07/12/2015 tiles.Atthetimeofinspectionthesewireswerenotlive.SinceIamunableto
determinewherethesewiresgo,andwhetherornottheycanstillbeenergized,
myrecommendationistocontactalicensedelectriciantorepairbothissuesas
needed.
Basement Bathroom
07/11/2015
Thereisaleakatthetoilet.Recommendcontactingaqualifiedplumberto
repairasneeded.
Exterior Grounds
Soilisincontactwithorlessthan6"fromsidingand/ortrim.Recommend
07/11/2015 gradingsoilsothere'satleast6"ofspacebetweenthesidingandtrimandthe
soilbelow.
07/11/2015
Areasofdrivewayinneedofrepair.Thiscouldleadtofurtherdamageifleftas
is.Recommendhavingaqualifiedcontractorrepairasneeded.
Insomespotsthefoundationpargecoatisdeteriorated.Thiscanallowmoisture
07/11/2015 topenetratethefoundationandcausefurtherdeterioration.Recommend
qualifiedcontractorrepairasnecessary.
Plantsandshrubsareincontactwithsiding,chimneyandA/Cunit.Recommend
07/14/2015 pruningormovingshrubssothere'satleastaonefootgapbetween
plants/shrubsandthesiding,chimneyandA/Cunit.
Exterior Walls
07/11/2015
Sidingisdamagedinoneareaatthefrontofthehouse.Aqualifiedcontractor
shouldbecontactedtorepairasnecessary.
GFCIonbackexteriorwallisnotworkingproperly.It'swiredcorrectlybutitdid
07/11/2015 nottripwhentested.Recommendcontactingalicensedelectriciantorepairas
needed.
07/11/2015
Cablelineistolowtotheground.Recommendcontactingcablecompanyand
havethemrepairasneeded.
07/11/2015
Thereisasectionofdeterioratedtrimonthebottomleft,nexttothestepsof
thefrontentrydoor.Recommendhavingaqualifiedcontractorrepairasneeded.
Mostwindowshaddeterioratedcaulkandgapsatthewindowflashing.Thiscan
07/14/2015 easilyallowwatertoleakintothehouse.Recommendcontactingqualified
contractortorepairasneeded.
General Interior
Intheclosetofoneofthebedroomsthereisanelectricalwirenotsecuredand
07/11/2015 danglingitsentrypointtothelight.Contactaqualifiedelectriciantorepairas
necessary.
07/11/2015
Lightindinningroomworks,butisnotproperlywired.Recommendaqualified
electricianrepairasneeded.
Behindthechairwiththegreencircleisanoutletthatisnotworkingatallandis
07/11/2015 alsonotattachedtothewallatall.Itwilljustpullrightoutfromthewall.
Recommendaqualifiedelectricianrepairasneeded.
Laundry
Thelaundryroomsinkhadacoupleofissues.First,Thereisasmallleakinthe
plumbingtowardsthefloor.Second,Iwasunabletodetermineiftherewasap
07/11/2015 trapattachedtothesinksplumbing.Itmaybeintheconcreteslab,orthere
maynotbeoneatall.Recommendhavingaqualifiedplumberfurtherevaluate
andrepairtheseissuesasneeded.
Roof & Ventilation
Treesareoverhangingroofandarewithin10feetofroofvertically.Recommend
07/11/2015 Contactingqualifiedcontractortoprunetreessothey'reatleast10feetabove
roof,ordon'toverhangtheroof.
Guttershadextensions,Theoneinthefrontofthehousewasnotlongenough
togetwaterawayfromthefoundation.Thishascausedsomemoistureintrusion
inthebasement.(whichwillbeaddressedinthebasementsectionofthis
07/11/2015
report.)Alsotheconcretepaverunderthegutterextensionisnotflatandtilts
towardsthehouse.whichisaddingtothegutterextensionissue.Recommenda
qualifiedcontractorrepairasneeded.
07/11/2015
Thereareafewbricktowardsthetopofthechimneythataredeterioratedand
inneedofrepair.Recommendcontactingaqualifiedmasontorepairasneeded.
Basement
Theceilingtilesinthebasementmaybemadeoutofsometypeofasbestoslike
material.Thereareafewfriabletilesthatmayneedtoberemoved.
07/11/2015
Recommendcontactingaqualifiedcontractortofurtherevaluateandrepairas
necessary.
Full Report
General Information
Start time:9:00AM
End time:11:00AM
Present at inspection:Owner
House is::Occupied
Type of house:1familyhouse
Weather condition:Clear
Temperature:Warm
Ground Condition:Dry
Foundation:Basement
Excluded from inspection:Shed
Excluded from inspection:SepticSystem
House Number:Noteasiliyseenfromstreet
Report Number:11773
Age of house:70Yearsold
Inspector:AndrewKotary
Concerningmoldinahome/building.Whilewewillreportanysubstancethat
appearstobemold,theonlytruewaytodetermineifmoldispresentistohave
amoldcompany/specialistinspectandtestformold.UpstateHomeInspection
07/09/2015 Servicedoesnotperformmoldtestingormoldinspection's.Anymentionof
moldinthisreportshouldbeconsideredarecommendationtobringinamold
specialisttoinspectandtestformold.Ifyouhaveaspecificconcernreguarding
mold,consultamoldspecialistforadvice.
07/09/2015
Thisisnotacodecompliantinspection.Thelocalmunicipalityshouldbe
contactedforanyquestionsorconcernsinrelationtolocalbuildingcodes.
Homewasoccupiedattimeofinspection.Somepartsofthehomemaynothave
07/11/2015 beenabletobeinspectedduetofurnitureandotherbelongingsthatmayhave
beeninthewayoftheinspector.
Recommendation:Aftermovingintothehouse,Istronglyrecommendhaving
thelockschanged.Overtheyears,previousownersmayhavedistributedthe
08/11/2015 keystofamilyandfriends.Anewsetoflockswouldinsureprivacyandsecurity.
Ifthehousehasremotegaragedooropeners,Iwouldrecommendchangingthe
codeaccessalso.
Roof ventilation:Gableandridgevents
BacktoTop
Treesareoverhangingroofandarewithin10feetofroofvertically.Recommend
07/11/2015 Contactingqualifiedcontractortoprunetreessothey'reatleast10feetabove
roof,ordon'toverhangtheroof.
Guttershadextensions,Theoneinthefrontofthehousewasnotlongenough
togetwaterawayfromthefoundation.Thishascausedsomemoistureintrusion
inthebasement.(whichwillbeaddressedinthebasementsectionofthis
07/11/2015
report.)Alsotheconcretepaverunderthegutterextensionisnotflatandtilts
towardsthehouse.whichisaddingtothegutterextensionissue.Recommenda
qualifiedcontractorrepairasneeded.
Rearofhouse
07/11/2015
Thereareafewbricktowardsthetopofthechimneythataredeterioratedand
inneedofrepair.Recommendcontactingaqualifiedmasontorepairasneeded.
Gutteratrearofhousehassomedebrisinit.thiscouldcausetheguttertoclog
07/11/2015 andoverflow.Recommendcleaninggutters.Thiswillhelpkeepmeltingsnow
andrainwaterfromcausingdamagetothehouse.
Thereseemstobetwolayersofshinglesontheroof.Thisisnotrecommended.
Thereseemstobetwolayersofshinglesontheroof.Thisisnotrecommended.
Sincetherearetwolayers,itmeansthatthesheathing,flashing,and
underlaymentmaynothavebeencheckedtoseeiftheywereinneedofrepair.
07/11/2015 Plus,withthefactthatthereisnoaccesstotheattic,itmakesitimpossibleto
knowifthisiscausinganyproblems.Recommendkeepinganeyeonthis
sectionofthehouse,andifanyproblemsarisecontactaqualifiedcontractorto
repairasneeded.
BacktoTop
Exterior Walls
Wall structure:Woodframe
Wall covering material:Vinyl
Condition of wall::Good
Trim:Vinyl
Trim condition:Good
Door material:Wood
Windows:Vinylwindows
Electrical service type:Overhead
07/11/2015
Sidingisdamagedinoneareaatthefrontofthehouse.Aqualifiedcontractor
shouldbecontactedtorepairasnecessary.
GFCIonbackexteriorwallisnotworkingproperly.It'swiredcorrectlybutitdid
GFCIonbackexteriorwallisnotworkingproperly.It'swiredcorrectlybutitdid
07/11/2015 nottripwhentested.Recommendcontactingalicensedelectriciantorepairas
needed.
07/11/2015
Cablelineistolowtotheground.Recommendcontactingcablecompanyand
havethemrepairasneeded.
07/11/2015
Thereisasectionofdeterioratedtrimonthebottomleft,nexttothestepsof
thefrontentrydoor.Recommendhavingaqualifiedcontractorrepairasneeded.
Mostwindowshaddeterioratedcaulkandgapsatthewindowflashing.Thiscan
07/14/2015 easilyallowwatertoleakintothehouse.Recommendcontactingqualified
contractortorepairasneeded.
BacktoTop
Exterior Grounds
Exterior of foundation walls:Block
Window wells:Metal
Grading within 6 foot of house:Aboutlevel
Grading beyond 6 foot of house:Slopesaway
Driveway:Asphalt
Driveway condition:Smallcracks
Walkway to front entry:Concrete
Walkway condition:Acceptable
Trees & shrubs too close to house:Ontherightofthehouse
Fence material:Wood
Fence condition:Feltsecure
A/C Compressor condition:Good
A/C during operation:Soundsgood
A/C air discharge:Warm
A/C low pressure refrigerant line::Insulated
A/C Pad:plastic
Electrical disonnect::Noted-Goodcondition
Exterior foundation exposure:Lessthan1foot
Exterior foundation observed?:deterioratedsurfaceswithsmallcracks
Window well condition:Acceptable
Walkwayisinacceptablecondition.Thereisonesectionthathassettledandis
nolongerlevel.Whichisaslip,trip,andfallhazard.Thissectionislocatedat
07/11/2015
thefrontofthehouseandrightnexttothedriveway.Recommendhavinga
qualifiedcontractorrepairasneeded.
Soilisincontactwithorlessthan6"fromsidingand/ortrim.Recommend
07/11/2015 gradingsoilsothere'satleast6"ofspacebetweenthesidingandtrimandthe
soilbelow.
07/11/2015
Areasofdrivewayinneedofrepair.Thiscouldleadtofurtherdamageifleftas
is.Recommendhavingaqualifiedcontractorrepairasneeded.
Insomespotsthefoundationpargecoatisdeteriorated.Thiscanallowmoisture
Insomespotsthefoundationpargecoatisdeteriorated.Thiscanallowmoisture
07/11/2015 topenetratethefoundationandcausefurtherdeterioration.Recommend
qualifiedcontractorrepairasnecessary.
Plantsandshrubsareincontactwithsiding,chimneyandA/Cunit.Recommend
07/14/2015 pruningormovingshrubssothere'satleastaonefootgapbetween
plants/shrubsandthesiding,chimneyandA/Cunit.
Therearehighmoisturelevelsbehindthesidingatthefrontofthehome.This
maybeoccurringduetothefactthatthereareslatetilesrightnexttothe
foundationofthehouse.Whichmaybecausingrainwatertosplashbehindthe
07/11/2015
siding,Thisismorethanlikelythesourceoftheproblem.Recommend
removingtheslatetiles,andmonitoringthisarea.Ifthisareacontinueshaving
moistureissuescontactaqualifiedcontractortorepairasneeded.
BacktoTop
Attic
Attic access:Noaccess
Noaccessdoorsorhatchwasfoundfortheattic.Theinspectorwasunableto
evaluatetheatticandinsidethekneewalls,anditisexcludedfromthis
inspection.Thepossibilityofproblemsdoesexist.Theremaybemold,flashing
07/11/2015
leaks,orinsulationissues.Recommendhavingaqualifiedcontractorinstall
accesshatchesasnecessaryandasperstandardbuildingpracticestoallowfor
periodicevaluationofatticspaces.
BacktoTop
Main Bathroom
Bathroom location:Secondfloorhallway
Shower:Withtub
Tub:Builtin
Surround:Ceramictile
Surround condition:Good
Number of sinks:One
Sink type:Pedastal
Toilet:Flushed
Toilet condition:Good
Floor:Ceramictile
Floor condition:Good
Leaks:Nonenoted
Caulking:Intact
Ventilation:FanandWindow
Outlets:One
GFI's:Yes
07/11/2015 Nomajordefectsintheupstairsbathroom.
accesstoshowerplumbing
BacktoTop
Basement Bathroom
Bath location:Basement
Bathroom outlet:Notnoted
Toilet:Notedandflushed-leaknoted
Floor:Vinyl
Floor:Ceramictile
Floor condition:Poor
Caulking appears::Missing
Ventilation:Fan
Number of sinks:None
Shower:stall
Surround:Sheetgoods
Wall Condition:Poor
Ceiling Condition:Poor
BasementBathroomseemstobeanadditionfromalongtimeago,thiswasnot
07/11/2015 builttostandardbuildingpractices.Recommendcontactingaqualifiedplumber
tofurtherevaluateandrepairasneeded.
07/11/2015
Thereisaleakatthetoilet.Recommendcontactingaqualifiedplumberto
repairasneeded.
Pictureisupsidedowntobetterreadmeter
Fireplace material:Brick
BacktoTop
Fireplace
Fireplace material:Brick
Fireplace Location:Familyroom
Inspected:Level1Inspection
Damper:Operatedandperformedasdesignred
Flu liner:Wasnotvisible
Depth of hearth extension:12inches
Depth of fireplace hearth:18inches
Fireplacewasinacceptableconditionattimeofinspection.Everythingoperated
07/11/2015 asitshould.Recommendhavingaleveltwoinspectionandcleaningdonebya
qualifiedchimneyservicecompany.
Condition of walls:Smallcracks
BacktoTop
General Interior
Condition of walls:Smallcracks
Stairs:Betweenlevelsandtobasement
Outlets:Mixof2and3prongedoutlets
Smoke detectors:NotNoted
Ceilings:Plaster
Ceiling style:Flat
Ceiling condition:Smallcracks
Walls appear to be made of:Plaster
Floor coverings:Hardwood
When bounced on:Anormalamountofbounce
Generally floors feel:Level
Mostly doors are following type:Wood
Condition of doors:Good
Windows were mostly:Doublehung
Windows appear made of:Vinyl
Stairs condition:Good
Intheclosetofoneofthebedroomsthereisanelectricalwirenotsecuredand
07/11/2015 danglingitsentrypointtothelight.Contactaqualifiedelectriciantorepairas
necessary.
07/11/2015
Lightindinningroomworks,butisnotproperlywired.Recommendaqualified
electricianrepairasneeded.
Behindthechairwiththegreencircleisanoutletthatisnotworkingatallandis
07/11/2015 alsonotattachedtothewallatall.Itwilljustpullrightoutfromthewall.
Recommendaqualifiedelectricianrepairasneeded.
Thereareafewcracksinthewallsandceilingsupstairs.Morethanlikelythisis
fromthehomesettlingthroughouttheyears.Recommendmonitoringthese
07/11/2015
areas.Ifareasgetworsecontactaqualifiedcontractortofurtherevaluatethe
situationandrepairasneeded.
BacktoTop
Kitchen
Cabinets:Wooden
Opened and closed and found:seemedtofunction
Cabinets are secure:Yes
Counter tops:SolidSurfaceMaterial
Counter tops securely fastened:Yes
Kitchen floor:Linoleum
Dishwasher age:Older
Kitchen sink:Porcelainovermetal
Ventilation:Fannoted
07/11/2015 Nomajordefectsfoundinthekitchenattimeofinspection.
BacktoTop
Laundry
Dryer vent material::Flexiblevinyltorigidmetal
Location::Basement
Washing machine::Maytag
Washing machine age::Older
Connections from water, drain & electric::Noted
Dryer::Maytag
Dryer age::Older
Dryer power::Electric
Vented to::Exterior
There'satwistinthedryerventline.Thiscancauselinttobecomecloggedin
07/11/2015 theline,whichcouldbecomeafirehazard.Recommendcontactingaqualified
contractortorepairasnecessary.
Thelaundryroomsinkhadacoupleofissues.First,Thereisasmallleakinthe
plumbingtowardsthefloor.Second,Iwasunabletodetermineiftherewasap
07/11/2015 trapattachedtothesinksplumbing.Itmaybeintheconcreteslab,orthere
maynotbeoneatall.Recommendhavingaqualifiedplumberfurtherevaluate
andrepairtheseissuesasneeded.
BacktoTop
Electrical System
Location of main disconnect:Inmainentryroom
Grounding observed to:Watermainonhouseside
Grounding connection feels:Secure
If grounded to water main, is meter jumped:Yes
Location of main panel:Basement
Type of protection:Circuitbreakers
Main disconnect rating:60Ampbreaker
Type of branch circuit wiring:NMsheathed(Romex)
Aluminum branch wiring present:No
Double tapped breakers:No
Additional room:Yes
Missing covers:No
15 amp breaker:14Guagewire
20 amp breaker:12Guagewire
20 amp breaker:14Guagewire
30 amp breaker:10Guagewire
Thehomeseemstohave60ampsforelectricalservice.Themaindisconnect
usesa100ampbreaker.Thisisaproblembecausethewiremayheatuptoo
07/14/2015
muchandpossiblycauseafirebeforethebreakertrips.Recommendcontacting
licensedelectriciantorepairasneeded.
07/14/2015
Ontherightsideoftheelectricalpanelthere'sanundersizedwire.Contacta
licensedelectriciantorepairasneeded.
Manufacturer:AOSmith
BacktoTop
Hotwaterheaterworkedproperlyattimeofinspection,Fromitsserialnumberit
07/11/2015 appearstobeolderthan10yearsoldandisolderthanitsestimatedusefullife.
Thishotwaterheatermayneedreplacingatanytime.
BacktoTop
Heating System
Apparent age of unit:Older
Heating system type:Forcedhotair
Energy source:Gas
Combustion air supply:Interior
Thermostat was turned on, the system:Firedorgaveheat
Emergency shut off:Attachedtounit
Flue pipes:Noted,piitchuptochimney
Flue pipes:Airgapnoted
System location:Basement
Brand name:Lennox
07/11/2015 Systemoperatedasdesignedondayofinspection.
07/11/2015
Recommendthatthissystembeservicedtothemanufacturer'ssuggested
maintenanceprogrambyaqualifiedheatingandcoolingtechnician.
BacktoTop
Air Conditioner
Brand:Lennox
Central Cooling:CentralAir
A/C Type:SplitSystem
Status:Operated
Approximate age of system:Midlife
A/C energy source:Electric
Conditioned Air:Feltcool
07/11/2015 Airconditioneroperatedasdesignedondayofinspection.
BacktoTop
Plumbing System
Water service type:Public
Main entry pipe:Galvanized
Location of main water meter:Basement
Location of main water shut-off:Nexttometer
Interior supply pipes:Copper
With multiple fixtures running:Acceptabledecreaseinflow
Waste system pipes:Castiron
Main waste line cleanouts:Noted
Vent pipe observed:Onroof
Waterwasranatthekitchensinkforthedurationoftheinspection.Otherthan
07/11/2015 theleaksdiscussedinthisreport,therewerenootheractiveleaksnotedattime
ofinspection.
BacktoTop
Basement
Basement access:Stairsfrominterior
Foundation walls:Exposedtoview
Ceiling framing:Hiddenfromview
Foundation walls made of:Concreteblock
Basement floor:Pouredconcreteslab
Water stains observed on:Walls
General area dampness:Somemoisturesigns
General area dampness:Dehumidifiernoted
Ventilation:Windows
Pier/support post material:Steel
Support column condition:Appearsintact
Sump pump:Submersiblepump
Sump pump works:Yes,butisnotGFIprotected
Floor structure above:Woodjoists
Insulation material:None
Beam material:Steel
Windows:Wood
Chimney in basement:Block
Chimney condition:Good
Floor drainage:Frenchdrainandsumppump
07/11/2015
Nobalustersonhandrailatbasementsteps.Thisisasafetyhazardandmay
leadtoinjury.Recommendrepairbyaqualifiedcontractor.
Theventpipesforthefurnaceandwaterheaterareventedintothechimney.
Theproblemsisthattherearegapswherethepipesenterintothechimney.
07/11/2015
Thiscancausecarbonmonoxidetoenterbackintothebasement.Recommend
aqualifiedcontractorrepairasneeded.
SumppumpisnotconnectedtoaGFIoutletandisalsopoweredwithan
07/11/2015 extensioncord.Extensioncordsshouldn'tbeusedforpermanentwiring.
Recommendalicensedelectricianrepairasneeded.
Inthebasementthereisajunctionboxlocatedontheceilingnearthelaundry
area.Thisjunctionboxismissingitscover,alsoontheceilingbetweenthegas
meterandthewatermain,thereareafewwiresstickingoutfromtheceiling
07/12/2015 tiles.Atthetimeofinspectionthesewireswerenotlive.SinceIamunableto
determinewherethesewiresgo,andwhetherornottheycanstillbeenergized,
myrecommendationistocontactalicensedelectriciantorepairbothissuesas
needed.
Theceilingtilesinthebasementmaybemadeoutofsometypeofasbestoslike
material.Thereareafewfriabletilesthatmayneedtoberemoved.
07/11/2015
Recommendcontactingaqualifiedcontractortofurtherevaluateandrepairas
necessary.
Somesignsofmoistureonfoundationwalls.Iftherepairtothegutterextension
07/11/2015 inatthefrontofthehomeiscompletedandtherestillseemstotobewater
enteringthefoundation,contactaqualifiedcontractortorepairasneeded.
BacktoTop
Safety Concerns
Outlets were tested for GFI:Usingatestingplug
Carbon Monoxide noted:No
NoCOdetectorsandoldersmokedetectorswerenotedinhouseattimeof
07/11/2015 inspection.Thisisasafetyrisk.RecommendinstallationofnewsmokeandCO
detectors.