You are on page 1of 1

Place Logo Here

Project : Alberta
OilSand
NG SURGE
DRUM

Eng : D Wu P Eng.

Job No : 1234567

Chk : D Wu P Eng.

Doc No : 1234567

Calculation Sheet

Date : 8/5/2014

Subject : Headed Anchor Bolt Design ACI 318-08

Rev : 1
1 of 9

ANCHOR BOLT DESIGN

Combined Tension and Shear

Anchor bolt design based on

Code Abbreviation

ACI 318-08 Building Code Requirements for Structural Concrete and Commentary Appendix D

ACI 318-08

PIP STE05121 Anchor Bolt Design Guide-2006

PIP STE05121

set Nu = 0 if it's compression

Anchor Bolt Data


Factored tension for design

Nu = 11.35

[kips]

Factored shear

Vu = 11.35

[kips]

Factored shear for design

Vu = 11.35

[kips]

Concrete strength

f'c = 4.0

[ksi]

[kN]

= 50.5

[kN]

Vu = 0 if shear key is provided


= 27.6

[MPa]

= 862

[MPa]

A193 Grade B7

Anchor bolt material


Anchor tensile strength

Code Reference
= 50.5

futa = 125

[ksi]

Anchor is ductile steel element


Anchor bolt diameter

da =

Bolt sleeve diameter

ds = 2.0

[in]

Bolt sleeve height

hs = 7.0

[in]

Anchor bolt embedment depth

hef = 15.0

[in]

9.0

OK

Concrete thickness

ha = 18.0

[in]

18.0

OK

Bolt edge distance c1

c1 = 5.0

[in]

4.5

OK

Bolt edge distance c2

c2 = 5.0

[in]

4.5

OK

Bolt edge distance c3

c3 = 5.0

[in]

4.5

OK

Bolt edge distance c4

c4 = 5.0

[in]

4.5

[in]

0.75

ACI 318-08
D.1

= 19.1

[mm]

PIP STE05121
Page A -1 Table 1

min required
Page A -1 Table 1

Page A -1 Table 1

OK

ACI 318-08

ci > 1.5hef for at least two edges to avoid reducing of hef when Nu > 0

No

D.5.2.3

Adjusted hef for design

hef = 15.00

[in]

9.0

OK

D.5.2.3

Outermost bolt line spacing s1

s1 = 54.0

[in]

3.0

OK

PIP STE05121

Outermost bolt line spacing s2

s2 = 54.0

[in]

3.0

OK

Page A -1 Table 1

Required No. of Bolts

= 2 / side (min)

You might also like