Professional Documents
Culture Documents
:
:
:
:
:
:
:
:
44
900
2.35
750
0.16
15
850
3500
Rafter
AS 1720.1-2010
Timber structures - Design methods
mm x 194 mm
mm
kN/m2
mm
kN/m2
degrees
kg/m3
mm
d =
724
mm
Spacing Number
Checks
1
2
3
Bending Moment
Shear Strenght
Deflection
SAFE
SAFE
SAFE
Loading
Wind
Roof
Purlin
Rafter
=
=
=
2.35 kN/m2 x
0.68 =
1.59 kN
0.16 kN/m2 x
0.68 =
0.11 kN
0.03 kN/m x
0.90 =
0.02 kN
Factored Load = F= 1.2Gv + W = 1.74
0.07 kN/m
Factored Load = w=1.35G
kN
Ra =
Rb =
0.10
4.47
5.34
kN
kN
kN
1 of 3
Rafter
Check
Bending Moment
M*
Md
M* < Md
f = 0.95
k1 = 1.0
k4 = 1.0
k6 = 1.0
f'b = 36 Mpa
For K9
Ncom =
Nmem =
3.710 kNm
K9 =
k12 =
1
>10
1.2
0.4
G31 =
1
G32 = 1.33
4.1619 kNm
AS 1720.1-2010
Page 25
s =
l =
=
K9 =
1.1603
0.9 m
3.5 m
1.2
For K12
d
b
Lay
s1 =
= 194
= 44
= 3500
23.41
22.94 if >
20
k12 =
Hence,
M*
3.710
<
fMd
< 4.1618779
0.0003
0.38
d =
b =
0.194
0.044
SAFE
Check
Shear Strenght
AS 1720.1-2010
V*
= 3.64 kN
=
f = 0.95
k1 = 1.0
k4 = 1.0
k6 = 1.0
f's = 3.3 Mpa
Vd
Hence,
V* < Vd
3.640 < 17.84
3.5
0.0057 m2
d =
b =
0.194 m
0.044 m
17.84024 kN
SAFE
2 of 3
Rafter
Check
Deflection
Actual deflection < Allowable deflection
=
k4 =
w =
L =
E =
1.0
3.09 kN/m
3.5 m
1E+10 N/m2
Hence,
0.194 m
0.044 m
3E-05 m4
11.67 mm
d =
b =
0.01877 mm
SAFE
3 of 3