You are on page 1of 13

EJERCICIO PRIMER PARCIAL

TOC = 0

r = 8.9
SFC = 1

F = 0.62
SFB = 1

g = 0
SFT = 1

= 26
Csg = 20

320
330
TOC = 0

F = 0.69
r = 10
SFC = 1.1 SFB = 1.1

2600

g = 0
SFT = 1.2

= 17
Csg = 13 3/8

2930
2950

TOC = 9000

11300

F = 0.73
r = 11.8
SFC = 1.1 SFB = 1.11

g = 0.1
SFT = 1.5

F = 0.76
SFB = 1.12

g = 0.1
SFT = 1.4

= 12 1/4
Csg = 9 5/8

11600
11620
TOC = 13500

r = 12.5
SFC = 1.12
16870
16890

CSG CONDUCTOR ( = 26 ; CSG = 20)


Pc = 0.052 * r * hf * SFC
= 0.052 * 8.9 * 320 * 1 = 148.096 psi

1) PcT > Pc

H40, 94,

520
PC ,

STC,

1530 18.936
Pb , Drift

=8
Csg = 7

Selecciono csg con criterios.

a = G < W (No)
b = W < G (No)
c < W < G (No)

Como no cumple ningn criterio se supone que la tubera


aguanta colapso.
Verifico por Burst
* PbX1 = F * hz - g(hz hx) 0.052 * r * hx
= 0.62 * 320 = 198.4
* PbX2 = 0.052 * rn * hn - gn(hn hx) 0.052 * r * hx
= 0.052 * 10 * 2950 = 1534
PbX1 < PbX2
hX 1 =

hX 1 =

(F g )hz PbT / SFB


0.052 * ( g )

(0.62 0)320 1530 / 1 = 2877.27


0.052 * (8.9 0)

Correccin por numero de tubos


# tubos = 320/ 40 = 8 tubos

Factores de seguridad
* SFC = PCT / Pcfondo = 520 / 148.096 = 3.51
Ph = 0.052 * 8.9 * 320 = 148.096
* SFB = PbT / Pbcalcula = 1530 / 198.4 = 7.71

* SFT = Ttabla / Tacumulado = 581000 / 30080 = 19.32


w.L = 94 * 320

CSG INTERMEDIO ( = 17
3/8)

1/2

; CSG = 13

Inicialmente
* PC = 0.052 * r * hz * SFC
= 0.052 * 10 * 2930 * 1.1
= 1675.96 psi

1) S-80 ; 61 ;

2040
Pc

; STC ;

3090
Pb

12.359
Drift

798000
T

12.515
I.D

Selecciono csg con criterios: * = G < W

2) S-80 ; 54.5 ;

1400
Pc

; STC ;

2730
Pb

689000
T

12.615
I.D

h = PcT / 0.052 * r * SFC = 1400 / 0.052 * 10 * 1.1


= 2447.55
Correccin por numero de tubos #1
Lsecc 1) = 2930- 2447.55= 482.45
# tubos = 482.45/ 40 = 12.06 13 tubos
Lsecc 1) correg = 13 * 40 = 520
hcorreg = 2930- 520 = 2410

Tensiones axiales
A1 = /4 (13.3752 12.5152) = 17.49
A2 = /4 (13.3752 12.6152) = 15.51
Ta1 = 0.052 * r * hz = 0.052 * 10 * 2930 = 1523.6 psi
Ta 2 =

Ta 2 =

Ta 1A1 - 0.052 * * h correg (A1 - A 2 )- w1L1


A2

(1523.6 *17.49)- 0.052 *10 * 2410(1.98)- (61 * 520)


15.51

Ta2 = - 487.01 psi


Como da negativo indica que en este punto la tubera se
encuentra en tensin y debe corregirse la altura:
h

Ta2

Fy

Pcc

2410

-487.01

0.993

1390.2

2432.87

-402.01

0.992

1388.8

2427.97
h correcta
luego:

h! =

1390.2
= 2432.87!
0.052 * 10 * 1.1

como h = 20.42 > 10, sigue la correccin:


Ta!2 =

(1523.6 *17.49)- 0.052 *10 * 2432.87(1.98)- (61 * (2930 - 2432.87 ))


15.51

Ta2 = - 402.01 psi


Con el nuevo valor de Pcc:

h!! =

1388.8
= 2427.97
0.052 * 10 * 1.1

Luego que h = 4.89 < 10


Correccin por numero de tubos #2
Lsecc 1) = 2930- 2427.97= 502.03
# tubos = 502.03/ 40 = 12.55 13 tubos

Verifico por Burst


* PbX1@ 0= F * hz - g(hz hx) 0.052 * r * hx
= 0.69 * 2930 = 2021.7
PbX1@ 2410= 0.69 * 2930 0.052 * 10 * 2410
= 768.5
* PbX2@ 0= 0.052 * rn * hn - gn(hn hx) 0.052 * r * hx
= 0.052 * 11.8 * 11620 * 0.1 (11620)
= 5968.03
Como PbX1 < PbX2
hX 1 =

hX 1 =

(F g )hz PbT / SFB


0.052 * ( g )

(0.69 0)2930 2730 / 1.1 = 884.84


(0.052 *10) 0

Como da negativo indica que la tubera ya se encuentra


en superficie y no sigo diseando.
Luego:
numero de tubos seccin 2):
# tubos = 2410/ 40 = 61 tubos
En superficie deben ser cortados 30 de tubera.

Factores de seguridad
Para tubera 1)
* SFC = PCT / Pcfondo = 2040 / 0.052 * 10 * 2930 = 1.34
* SFB = PbT / Pbcalculado = 3090 / 768.5 = 4.02
* SFT = Ttabla / Tacumulado = 798000 / 61 * 520 = 25.16
Para tubera 2)
* SFC = PCT / Pcfondo = 1400 / 0.052 * 10 * 2410 = 1.12
* SFB = PbT / Pbcalculado = 2730 / 2021.07 = 1.35
* SFT = 689000 / (61 * 520) + (54.5 * 2410) = 4.23

CSG INTERMEDIO
5/8)

( = 12 ; CSG = 9

* PC = 0.052 * r * hz * SFC
= 0.052 * 11.8 * 11600 * 0.8
= 5694.2 psi
Por efectos del TOC en esta seccin se asume un SFC < 1

1) S-95 ; 47 ;

7100
Pc

; LTC ;

8150
Pb

8.525
Drift

Selecciono csg con criterios: * = G < W

2) S-95 ; 43.5 ;

5600
Pc

; LTC ;

7510
Pb

h = PcT / 0.052 * r * SFC = 5600 / 0.052 * 11.8 * 1.1


= 8296.788
Tensiones axiales
A1 = /4 (9.6252 8.6812) = 13.57
A2 = /4 (9.6252 8.7552) = 12.56

A1 A2 = 1.01

Ta1 = 0.052 * r * hz = 0.052 * 11.8 * 11600 = 7117.76 psi


Ta 2 =

Ta 2 =

Ta 1 A 1 - 0.052 * * h calculada (A 1 - A 2 )- w 1 L1
A2

(7117.76 *13.57 )- 0.052 *11.8 * 8296.788(1.01)- (47 * 3303.212)


12.56

Ta2 = - 5079.99 psi


Como es negativo, indica que a la profundidad h la seccin se
encuentra en tensin y por lo tanto debe corregirse:
H

Ta2

Fy

Pcc

8296.788 -5079.99 0.973

5448.8

8072.774 -5907.21 0.968

5420.8

8031.29

5415.2

-6060.40 0.967

8022.99
h correcta

luego:

h! =

como h > 10

5448.8
= 8072.77!
0.052 * 11.8 * 1.1

Ta2 = - 5907.21 psi


Ta2 = - 6060.40 psi
como hfinal = 8.61 < 10, se termina la correccin.
Finalmente, corrijo altura por nmero de tubos:
L = 11600- 8022.99= 3577.006
# tubos = 3577/ 40 = 89.42 90 tubos
Lreal corregido = 90 * 40 = 3600
hreal corredida = 11600 3600 = 8000
Verifico por Burst
PbX1= (0.73 * 11600) 0.1 (11600 8000) 0.052 * r * 8000
= 3199.2 psi
PbX2 = (0.052 * 12.5 * 16890) 0.1 (16890 8000) 0.052 * 11.8 * 8000
= 5180.7 psi
Como PbX1 < PbX2
hX 1 =

hX 1 =

(F g )hz PbT / SFB


0.052 * ( g )

(0.73 0.1)11600 7510 / 1.11 = 1055.75


(0.052 *11.8) 0.1

Como ya sube hasta 1055.75 significa que hasta all se deja el


diseo, puesto que el zapato se encuentra a 2600.

Se corrige por nmero de tubos:


Lreal = 8000 2600 = 5400
# tubos = 5400/ 40 = 135 tubos
2

Este es el nmero de tubos necesarios para la


2).

seccin
1

Factores de seguridad
Para tubera 1)
* SFC = 7100 / 0.052 * 11.8 * 11600 = 0.99
* SFB = 8150 / (0.73 * 11600) 0.1 (11600 8000) 0.052 * 11.8 * 8000
= 2.55
* SFT = 1053000 / 47 * 3600 = 6.22
Para tubera 2)
* SFC = 5600 / 0.052 * 11.8 * 8000 = 1.14
* SFB = 7510 / (0.73 * 11600) 0.1 (11600 2600) 0.052 * 11.8 * 2600
= 1.26
* SFT = 959000 / (47 * 3600) + (43.5 * 5400) = 2.37

LINER ( = 8 ; CSG = 7 )
* PC = 0.052 * r * hz * SFC
= 0.052 * 12.5 * 16870 * 0.8
= 8772.4 psi

1) S-95 ; 29 ;

9200
Pc

; LTC ;

9690
Pb

Selecciono csg con criterios: * = G < W

2) S-95 ; 26 ;

7800
Pc

; LTC ;

8600
Pb

h = 7800 / 0.052 * 12.5 * 1.12


= 10714.28
Tensiones axiales
A1 = /4 (72 6.1842) = 8.45
A2 = /4 (72 6.2762) = 7.55

A1 A2 = 0.9

Ta1 = 10965.5 psi


Ta2 = -12202.02 psi
Como es negativo, se corrige:
h

Ta2

Fy

Pcc

10714.28 -12202.02

0.929 7246.2

9953.57

-15065.01

0.91

9750

-15831.16

0.909 7090.2

7098

9739.28
h correcta
luego:

h! =

7246.2
= 9953.57
0.052 * 12.5 * 1.12

como h > 10
Se corrige nuevamente Ta2 = -15065.01

Ta2 = -15831.16
A la profundidad correcta (9739.28) ya se esta por encima del
zapato.
Correccin por nmero de tubos:
L = 16870- 11300= 5570
# tubos = 5570/ 40 = 139.25 140 tubos
Para llegar hasta el zapato solo se utiliza la tubera 1).
Factores de seguridad
* SFC = 9200 / 0.052 * 12.5 * 16870 = 0.84

* SFB = 9690 / (0.76 * 16870) 0.1 (16870 11300) 0.052 *


= 1.97
* SFT = 692000 / 29 * 5570 = 4.28

Teniendo en
cuenta que
se asume
SFC = 0.8

12.5 * 11300

FINALMENTE EL DISEO:

TOC = 0

H40, 94, STC


320
330

TOC = 0

S-80 ; 54.5 ; STC

2410
2600

S-80 ; 61 ; STC

2930
2950

S-95 ; 43.5 ; LTC

8000
TOC = 9000

= 26
Csg = 20

= 17
Csg = 13 3/8

S-95 ; 47 ; LTC

= 12 1/4
Csg = 9 5/8

S-95 ; 29 ; LTC

=8
Csg = 7

11300
11600
11620
TOC = 13500

16870
16890

EVALUACION DE COSTOS

Tipo de Csg

# de tubos (de Costo unitario Costo total de


40)
del tubo (U cada Csg (U$)
$x100)

H40, 94, STC

5162,24

16519,168

S-80 ; 54.5 ;
STC

61

2828,53

69061,132

S-80 ; 61 ; STC

13

3143,86

16348,072

S-95 ; 43.5 ;
LTC

135

3007,88

162425,52

S-95 ; 47 ; LTC

90

3421,41

123170,76

S-95 ; 29 ; LTC

140

2130,43

119304,08

COSTO TOTAL (U$)

506828,732