Professional Documents
Culture Documents
108W6614
16111805 - 813
Aratua-1 / 712835
BioEnergy
Kunde /
Customer:
Frequenz / Frequency
Nennspannung / Rated Voltage
Steuerspannung / Control Voltage
50 / 60Hz
690V / 400V
230VAC / 24VDC
2
GE Energy
SIGNATURE
REV
DESCRIPTION
new release
ECO1112257
CHECKED BY
SEE PLM
REVISED BY
GE Energy
SEE PLM
DRAWN
105050000
ISSUED
SEE PLM
14-JUN-2011
DRAWN
105050000
CHECKED
SEE PLM
ENGINEER
SEE PLM
ISSUED
SEE PLM
DATE
14-JUN-2011
Project schematics
TYPE
COMPONENT
= GI
1.6 xle
Project schematics
COMP NO.
next
COMP-DRW. NO.
COMP-PART NO.
108W6614
N/A
REV
Sh.
of
1
3
Revision overview
Date
14.Jun.2011
previous
REV
108W6614
Revision
Aratua-1 / 712835
Revision description
Page name
new release
ECR / ECO
all
ECO1112257
1
DESCRIPTION
new release
ECO1112257
3
CHECKED BY
SEE PLM
REVISED BY
GE Energy
SEE PLM
DRAWN
105050000
ISSUED
SEE PLM
14-JUN-2011
Modification information
TYPE
COMPONENT
1.6 xle
Project Schematics
COMP NO.
next
= GI
COMP-DRW. NO.
COMP-PART NO.
108W6614
N/A
REV
Sh.
of
2
3
Component overview
Identifier
previous
REV
Cable No.
108W6614
Aratua-1 / 712835
Component
Revision
=GI
N/A
General Information
N/A
108W6614
=DOCU
N/A
N/A
104W6321
=OneLines
N/A
N/A
107W5365
=PDC
107W5379P001
107W4611
=CFC
107W5379P001
107W4611
=MCC
107W5379P001
107W4611
=CBC
107W5379P001
107W4611
=TB
Top Box
107W5345P001
107W6155
=GT
Gearbox 60 Hz
104W3938P001
104W3892
=GE
Generator
108W5204P001
104W2742
=SR
Slipring
104W5966P001
104W5916
=PCS
16
104W2609P001
104W4611
=PCS
26
104W2609P001
104W4611
=PCS
36
104W2609P001
104W4611
=PCS
15
Pitch System
104W2610P001
104W4611
2
DESCRIPTION
new release
ECO1112257
=DOCU/1
CHECKED BY
SEE PLM
REVISED BY
GE Energy
SEE PLM
DRAWN
105050000
ISSUED
SEE PLM
14-JUN-2011
Table of contents
TYPE
COMPONENT
1.6 xle
Project Schematics
COMP NO.
next
= GI
COMP-DRW. NO.
COMP-PART NO.
108W6614
N/A
REV
Sh.
of
3
3
Cover Page
GE Wind Energy 1.6MW
WTG Drw No.:
WTG No.:
Project/CMS No.:
Customer:
Component:
Comp No.:
Comp-Drw. No.:
Comp-Part No.:
Frequency:
Rated Voltage:
Control Voltage:
108W6614
16111805 - 813
Aratua-1 / 712835
BioEnergy
104W6321
N/A
50 / 60 Hz
690V / 400V
230V / 24VDC
System Cover Page 1.5 ESS
=GI/3
previous
REV
DESCRIPTION
2
CHECKED BY
REVISED BY
18-MAR-2009 18-MAR-2009
J. Chacon
R. Shaw
GE Energy
DRAWN
ISSUED
25-APR-2008 G.Stultz
DWB
COMPONENT
TYPE
1.6 xle
COMP-DRW. NO.
104W6321
COMP-PART NO.
N/A
REV
next
= DOCU
+
Sh
of
1
8
date
revision
change
Copied from 104W5562P001. Updated DTA Schematic (PDC, CFC, CBC, and MCC) and Top Box Schematic with changes for production
(both given new part numbers). Updated following sections from previous schematic: PSCB, OneLines.
12/18/07
03/07/08
04/25/08
10/09/08
11/10/08
Updated
Updated
Updated
Updated
03/18/09
page
12/4/07
1
previous
REV
DESCRIPTION
actual state
3
CHECKED BY
REVISED BY
18-MAR-2009 18-MAR-2009
J. Chacon
R. Shaw
GE Energy
DRAWN
ISSUED
25-APR-2008 G.Stultz
DWB
Modification Page
COMPONENT
TYPE
1.6 xle
COMP-DRW. NO.
COMP-PART NO.
104W6321
REV
next
= DOCU
+
Sh
of
2
8
Contents
Page
Page designation
Date
User.
23.Mai.2011
105050000
23.Mai.2011
105050000
=GI+/1
=GI+/2
Modification information
=GI+/3
Table of contents
23.Mai.2011
105050000
=DOCU+/1
23.Mai.2011
105050000
=DOCU+/2
Modification Page
23.Mai.2011
105050000
=DOCU+/3
Contents
23.Mai.2011
105050000
=DOCU+/4
Contents
23.Mai.2011
105050000
=DOCU+/5
Contents
23.Mai.2011
105050000
=DOCU+/6
Contents
23.Mai.2011
105050000
=DOCU+/7
Contents
23.Mai.2011
105050000
=DOCU+/8
Contents
23.Mai.2011
105050000
=OneLines+/1
Documentation
23.Mai.2011
105050000
=OneLines+/2
Documentation
23.Mai.2011
105050000
=OneLines+/3
Documentation
23.Mai.2011
105050000
=OneLines+/4
Documentation
23.Mai.2011
105050000
=OneLines+/5
Documentation
23.Mai.2011
105050000
=OneLines+/6
Documentation
23.Mai.2011
105050000
=OneLines+/7
Documentation
23.Mai.2011
105050000
=OneLines+/8
Documentation
23.Mai.2011
105050000
=PDC+/1
Documentation
23.Mai.2011
105050000
=PDC+/2
Documentation
23.Mai.2011
105050000
=PDC+/3
Documentation
23.Mai.2011
105050000
=PDC+/4
Documentation
23.Mai.2011
105050000
=PDC+/5
Power Distribution Cabinet Conv Line Fuses, DC Bus Charger, & Line Filter
Documentation
23.Mai.2011
105050000
=PDC+/6
Documentation
23.Mai.2011
105050000
=PDC+/7
Documentation
23.Mai.2011
105050000
=CFC+/1
Documentation
23.Mai.2011
105050000
=CFC+/2
Documentation
03.Nov.2009
105050000
=CFC+/3
Documentation
02.Dez.2009
105050000
=CFC+/4
Documentation
02.Dez.2009
105050000
2
previous
REV
DESCRIPTION
1.5/50Hz
4
CHECKED BY
REVISED BY
18-MAR-2009 18-MAR-2009
J. Chacon
R. Shaw
GE Energy
DRAWN
ISSUED
25-APR-2008 G.Stultz
DWB
Contents
COMPONENT
TYPE
1.6 xle
COMP-DRW. NO.
COMP-PART NO.
104W6321
REV
next
= DOCU
+
Sh
of
3
8
Contents
Page
Page designation
Date
User.
=CFC+/5
Documentation
02.Dez.2009
105050000
=CFC+/6
Documentation
02.Dez.2009
105050000
=MCC+/1
Documentation
23.Mai.2011
105050000
=MCC+/2
Documentation
03.Nov.2009
105050000
=MCC+/3
Documentation
02.Dez.2009
105050000
=MCC+/4
Documentation
02.Dez.2009
105050000
=MCC+/5
Documentation
02.Dez.2009
105050000
=MCC+/6
Documentation
02.Dez.2009
105050000
=MCC+/7
Documentation
02.Dez.2009
105050000
=MCC+/8
Documentation
02.Dez.2009
105050000
=MCC+/9
Documentation
02.Dez.2009
105050000
=MCC+/10
Documentation
02.Dez.2009
105050000
=MCC+/11
Documentation
02.Dez.2009
105050000
=MCC+/12
Documentation
02.Dez.2009
105050000
=MCC+/13
Documentation
02.Dez.2009
105050000
=MCC+/14
Documentation
02.Dez.2009
105050000
=MCC+/15
Documentation
02.Dez.2009
105050000
=MCC+/16
Documentation
02.Dez.2009
105050000
=MCC+/17
Documentation
02.Dez.2009
105050000
=MCC+/18
Documentation
02.Dez.2009
105050000
=MCC+/19
Documentation
02.Dez.2009
105050000
=MCC+/20
Documentation
02.Dez.2009
105050000
=MCC+/21
Documentation
02.Dez.2009
105050000
=MCC+/22
Documentation
02.Dez.2009
105050000
=MCC+/23
Documentation
02.Dez.2009
105050000
=MCC+/24
Documentation
02.Dez.2009
105050000
=MCC+/25
Documentation
02.Dez.2009
105050000
=CBC+/1
Documentation
23.Mai.2011
105050000
=CBC+/2
Documentation
23.Mai.2011
105050000
=CBC+/3
Documentation
23.Mai.2011
105050000
3
previous
REV
DESCRIPTION
5
CHECKED BY
REVISED BY
18-MAR-2009 18-MAR-2009
J. Chacon
R. Shaw
GE Energy
DRAWN
ISSUED
25-APR-2008 G.Stultz
DWB
Contents
COMPONENT
TYPE
1.6 xle
COMP-DRW. NO.
COMP-PART NO.
104W6321
REV
next
= DOCU
+
Sh
of
4
8
Contents
Page
Page designation
Date
User.
=CBC+/4
Documentation
23.Mai.2011
105050000
=CBC+/5
Documentation
23.Mai.2011
105050000
=CBC+/6
Documentation
23.Mai.2011
105050000
=TB+/1
Documentation
23.Mai.2011
105050000
=TB+/2
Documentation
23.Mai.2011
105050000
=TB+/3
Documentation
23.Mai.2011
105050000
=TB+/4
Documentation
23.Mai.2011
105050000
=TB+/5
Documentation
23.Mai.2011
105050000
=TB+/6
Documentation
23.Mai.2011
105050000
=TB+/7
Documentation
23.Mai.2011
105050000
=TB+/8
Documentation
23.Mai.2011
105050000
=TB+/9
Documentation
23.Mai.2011
105050000
=TB+/10
Documentation
23.Mai.2011
105050000
=TB+/11
Documentation
23.Mai.2011
105050000
=TB+/12
Documentation
23.Mai.2011
105050000
=TB+/13
Documentation
23.Mai.2011
105050000
=TB+/14
Documentation
23.Mai.2011
105050000
=TB+/15
Documentation
23.Mai.2011
105050000
=TB+/16
Top Box Elementary Yaw Contactor Pilot Relays/ Control Breaker Status
Documentation
23.Mai.2011
105050000
=TB+/17
Documentation
23.Mai.2011
105050000
=TB+/18
Documentation
23.Mai.2011
105050000
=TB+/19
Documentation
23.Mai.2011
105050000
=TB+/20
Documentation
23.Mai.2011
105050000
=TB+/21
Documentation
23.Mai.2011
105050000
=TB+/22
Documentation
23.Mai.2011
105050000
=TB+/23
Documentation
23.Mai.2011
105050000
=TB+/24
Documentation
23.Mai.2011
105050000
=TB+/25
Documentation
23.Mai.2011
105050000
=TB+/26
Documentation
23.Mai.2011
105050000
=TB+/27
Documentation
23.Mai.2011
105050000
4
previous
REV
DESCRIPTION
6
CHECKED BY
REVISED BY
18-MAR-2009 18-MAR-2009
J. Chacon
R. Shaw
GE Energy
DRAWN
ISSUED
25-APR-2008 G.Stultz
DWB
Contents
COMPONENT
TYPE
1.6 xle
COMP-DRW. NO.
COMP-PART NO.
104W6321
REV
next
= DOCU
+
Sh
of
5
8
Contents
Page
Page designation
Date
User.
=TB+/28
Documentation
23.Mai.2011
105050000
=TB+/29
Documentation
23.Mai.2011
105050000
=TB+/30
Documentation
23.Mai.2011
105050000
=TB+/31
Documentation
23.Mai.2011
105050000
=GT+/1
23.Mai.2011
105050000
=GT+/2
Modification information
23.Mai.2011
105050000
=GT+/3
general information
23.Mai.2011
105050000
=GT+/4
23.Mai.2011
105050000
=GT+/4a
23.Mai.2011
105050000
=GT+/5
Contents
23.Mai.2011
105050000
=GT+/10
Temprerature sensors
23.Mai.2011
105050000
=GT+/11
23.Mai.2011
105050000
=GT+/12
23.Mai.2011
105050000
=GT+/13
Drives 690V
23.Mai.2011
105050000
=GT+/14
Heaters 690V/230V
23.Mai.2011
105050000
=GE+S1/1
Cover Page
1.5\1.6kW 50Hz
23.Mai.2011
105050000
=GE+S1/2
Modification Information
1.5\1.6kW 50Hz
23.Mai.2011
105050000
=GE+S1/3
General Information
1.5\1.6kW 50Hz
23.Mai.2011
105050000
=GE+S1/4
Table of Contents
1.5\1.6kW 50Hz
23.Mai.2011
105050000
=GE+S1/5
1.5\1.6kW 50Hz
23.Mai.2011
105050000
=GE+S1/6
1.5\1.6kW 50Hz
23.Mai.2011
105050000
=GE+S1/7
1.5\1.6kW 50Hz
23.Mai.2011
105050000
=GE+S1/8
1.5\1.6kW 50Hz
23.Mai.2011
105050000
=GE+S1/9
Standby Heater
1.5\1.6kW 50Hz
23.Mai.2011
105050000
=GE+S1/10
1.5\1.6kW 50Hz
23.Mai.2011
105050000
=GE+S1/11
1.5\1.6kW 50Hz
23.Mai.2011
105050000
=GE+S1/12
1.5\1.6kW 50Hz
23.Mai.2011
105050000
=SR+/1
23.Mai.2011
105050000
=SR+/2
23.Mai.2011
105050000
=SR+/3
23.Mai.2011
105050000
5
previous
REV
DESCRIPTION
7
CHECKED BY
REVISED BY
18-MAR-2009 18-MAR-2009
J. Chacon
R. Shaw
GE Energy
DRAWN
ISSUED
25-APR-2008 G.Stultz
DWB
Contents
COMPONENT
TYPE
1.6 xle
COMP-DRW. NO.
COMP-PART NO.
104W6321
REV
next
= DOCU
+
Sh
of
6
8
Contents
Page
Page designation
Date
User.
=SR+/4
23.Mai.2011
105050000
=SR+/5
23.Mai.2011
105050000
=PCS+Ax1/1
Documentation
23.Mai.2011
105050000
=PCS+Ax1/2
Documentation
23.Mai.2011
105050000
=PCS+Ax1/3
Documentation
23.Mai.2011
105050000
=PCS+Ax1/4
Documentation
23.Mai.2011
105050000
=PCS+Ax1/5
Documentation
23.Mai.2011
105050000
=PCS+Ax1/6
Documentation
23.Mai.2011
105050000
=PCS+Ax1/7
Axis Box 1 - Signals from Center Box & 230Vac Fan and Heater Controls
Documentation
23.Mai.2011
105050000
=PCS+Ax1/8
Battery Box 1
Documentation
23.Mai.2011
105050000
=PCS+Ax1/9
Battery Box 1
Documentation
23.Mai.2011
105050000
=PCS+Ax1/10
Documentation
23.Mai.2011
105050000
=PCS+Ax2/1
Documentation
23.Mai.2011
105050000
=PCS+Ax2/2
Documentation
23.Mai.2011
105050000
=PCS+Ax2/3
Documentation
23.Mai.2011
105050000
=PCS+Ax2/4
Documentation
23.Mai.2011
105050000
=PCS+Ax2/5
Documentation
23.Mai.2011
105050000
=PCS+Ax2/6
Documentation
23.Mai.2011
105050000
=PCS+Ax2/7
Axis Box 2 - Signals from Center Box & 230Vac Fan and Heater Controls
Documentation
23.Mai.2011
105050000
=PCS+Ax2/8
Battery Box 2
Documentation
23.Mai.2011
105050000
=PCS+Ax2/9
Battery Box 2
Documentation
23.Mai.2011
105050000
=PCS+Ax2/10
Documentation
23.Mai.2011
105050000
=PCS+Ax3/1
Documentation
23.Mai.2011
105050000
=PCS+Ax3/2
Documentation
23.Mai.2011
105050000
=PCS+Ax3/3
Documentation
23.Mai.2011
105050000
=PCS+Ax3/4
Documentation
23.Mai.2011
105050000
=PCS+Ax3/5
Documentation
23.Mai.2011
105050000
=PCS+Ax3/6
Documentation
23.Mai.2011
105050000
=PCS+Ax3/7
Axis Box 3 - Signals from Center Box & 230Vac Fan and Heater Controls
Documentation
23.Mai.2011
105050000
=PCS+Ax3/8
Battery Box 3
Documentation
23.Mai.2011
105050000
6
previous
REV
DESCRIPTION
8
CHECKED BY
REVISED BY
18-MAR-2009 18-MAR-2009
J. Chacon
R. Shaw
GE Energy
DRAWN
ISSUED
25-APR-2008 G.Stultz
DWB
Contents
COMPONENT
TYPE
1.6 xle
COMP-DRW. NO.
COMP-PART NO.
104W6321
REV
next
= DOCU
+
Sh
of
7
8
Contents
Page
Page designation
Date
User.
=PCS+Ax3/9
Battery Box 3
Documentation
23.Mai.2011
105050000
=PCS+Ax3/10
Documentation
23.Mai.2011
105050000
=PCS+PS/1
Documentation
23.Mai.2011
105050000
=PCS+PS/2
Documentation
23.Mai.2011
105050000
=PCS+PS/3
Documentation
23.Mai.2011
105050000
=PCS+PS/4
Documentation
23.Mai.2011
105050000
=PCS+PS/5
Documentation
23.Mai.2011
105050000
=PCS+PS/6
Documentation
23.Mai.2011
105050000
=PCS+PS/7
Documentation
23.Mai.2011
105050000
=PCS+PS/8
Documentation
23.Mai.2011
105050000
7
previous
REV
DESCRIPTION
=OneLines/1
CHECKED BY
REVISED BY
18-MAR-2009 18-MAR-2009
J. Chacon
R. Shaw
GE Energy
DRAWN
ISSUED
25-APR-2008 G.Stultz
DWB
Contents
COMPONENT
TYPE
1.6 xle
COMP-DRW. NO.
COMP-PART NO.
104W6321
REV
next
= DOCU
+
Sh
of
8
8
Cover Page
GE Wind Energy 1.6MW
WTG Drw No.:
WTG No.:
Project/CMS No.:
Customer:
Component:
Comp No.:
Comp-Drw. No.:
Comp-Part No.:
Frequency:
Rated Voltage:
Control Voltage:
108W6614
16111805 - 813
Aratua-1 / 712835
BioEnergy
107W5365
N/A
50 / 60 Hz
690V / 400V
230V / 24VDC
2
DATE
=DOCU/8
previous
REV
DESCRIPTION
CHECKED BY
REVISED BY
12-MAR-2009 12-MAR-2009
R. Shaw
J. Chacon
GE Energy
DRAWN
ISSUED
25-APR-2008 G.Stultz
DWB
SIGNATURE
ENGINEER
4-DEC-2007
DRAWN
25-APR-2008 G.Stultz
CHECKED
25-APR-2008
ISSUED
next
GE Energy
T. Klodowski
A. Ridenour
DWB
COMPONENT
TYPE
1.6 xle
= OneLines
+
COMP-DRW. NO.
107W5365
COMP-PART NO.
N/A
REV
Sh
of
1
8
date
revision
change
page
03/07/08
Moved FU1A,B,C fuse to before FB1 & FB2. Changed F6 from 25 to 32A.
Deleted sheet 6. Moved sheet 7 to 6 & improved layout.
04/25/08
Added 2 sheets
09/17/08
Updated Border
11/10/08
12,29,30,31
03/12/09
1,3
12/4/2007
actual state
3, 4
4, 6,7
1
previous
REV
DESCRIPTION
CHECKED BY
REVISED BY
12-MAR-2009 12-MAR-2009
J. Chacon
R. Shaw
GE Energy
DRAWN
ISSUED
25-APR-7008
DWB
G. Stultz
6,7
COMPONENT
1.6 xle
3 next
= OneLines
+
TYPE
COMP-DRW. NO.
COMP-PART NO.
107W5365
REV
Sh
of
2
8
Main Transformer
MV CB
LOTO
for Tower
= PDC/3
Main Breaker
Enclosure
690 Y
CT4,5,6
=CFC/3
K1
= PDC/4
CT1,2,3
=PDC/4
GEN
Stator
Q1
2000A
Motor Operated
(Converter)
FU1A,B,C
PEN
(External Devices)
355A
(Arc Flash)
Q6
ACLFU1,2,3
ROTOR
1A
350A
=PDC/6
=PDC/5
I>
=PDC/4
Stator Current
Fbk.
MCC
TB2
=MCC/12
To Converter
(Grid Current Fbk.)
FB2
FB1
100A
F4
F5
F6
200A
F1
F2
F3
Q5
1A
CBC
=PDC/6
Q2
L2
CCR1,2,3
Shunt
SHA/B/C1
Charge CKT
=CFC/6
=PDC/5
=CFC/4
I>
=MCC/10
Grid Voltage
Fbk.
I>
FB4
/
X2.1
=MCC/10
Voltage
Test
Socket
230V
Power
1A
=PDC/6
FB3
PDC
Aux Panel
690V Distribution
ROVC
LFC
1,2,3
=CFC/4
Rotor OverVoltage
Contactor
T2
80A
32.5 KVA
Pri:690 Vac
Sec: 400/230V
208/120 or 173/100
Z=4%-6%
=PDC/6
MCC
X2.1
=CFC/3
=MCC/10
230V 1ph
Rotor
Converter
40A
=PDC/6
LFR
KDF
DC
Cap
Line
Converter
Q3
Shunt
SHA/B/C2
1A
=PDC/6
Energy
Meter
(Optional)
L1
CCONT
I>
TB1
=MCC/10
To CBC Internal
Fans
=CBC/6
Converter Filter
CabinetCFC
(Commissioning Back-Feed)
=MCC/23
/5.5
6A
=MCC/5
Q23
T3
=MCC/5
=MCC/5
WEMA
K4
=MCC/5
UPS
230V, 1ph
=MCC/5
J5
Q21
=MCC/3
I>
I>
208V or
400V
3ph
Q12
20A
6A
=CFC/3
=MCC/23
Q10
Q11
20A
20A
Q18
Q19
Q20
10A
10A
10A
K1,K2,K3
K13,K14,K15
=MCC/4
/ Heat
Control
P14
J5A,B,C
=MCC/6
(UCSA)
Q13
6A
=MCC/3
J9
24 Vdc
Turbine Controller
Q14
6A
230V , 1ph
ENV_OK
Q9
20A
/5.4
16A
=MCC/5
/5.4
16A
230V, 1ph
=PDC/7
K5
K3
=MCC/3
=MCC/3
X3.4
Surge Suppressor
Status Contacts
=MCC/5, =PDC/3
Heaters
=CBC/6, =PDC/5
=CFC/5
Pump
=CFC/5, =MCC/15
DTA- Main
Cooling Fan
GFI
X3.2
Spare
=MCC/3
X3.2
400/230V
Top Box
X4.2
3Ph
Hoist
X5.1
Emerg. Lighting,
Tower Lighting,
FAA Lights,
&
Nacelle Lighting
GFI
I>
=CFC/3
Q22
=MCC/10
X4.1
30A
400/230 V
3 ph to DTA
I>
UPS
to
Top
Box
Q8
Q24
X5.1
X5.1
Supply
Sockets
&
Motion Lights
Obstruction
Lights
&
Met Mast
2
previous
REV
DESCRIPTION
CHECKED BY
REVISED BY
12-MAR-2009 12-MAR-2009
J. Chacon
R. Shaw
GE Energy
DRAWN
ISSUED
25-APR-7008
DWB
G. Stultz
COMPONENT
1.6 xle
4 next
= OneLines
+
TYPE
COMP-DRW. NO.
COMP-PART NO.
107W5365
REV
Sh
of
3
8
F1
690V from
DTA
=CFC/3
32A
F2
F6
20A
32A
=TB/3
=TB/3
690V to
Pitch
System
=TB/3
Surge
Suppressor
Q6
Q7
Q8
Q10A,B,C
Q9
1.6A
10A
13A
2.5A
2.5A
=TB/4
F7
=TB/4
I>
I>
=TB/4
I>
=TB/5
I>
=TB/5
I>
=TB/3
K3
Q1
25A
=TB/3
I>
K4
=TB/4
Note: With
shunt trip
capability
K6
=TB/5
Generator
Fan Cooling
Circuit 2
=TB/5
Gearbox
Heating
Elements
Generator
Standby
Heater
Reversing
Contactor
K1
K2
=TB/3
=TB/3
Q2
Q3
Q4
Q5
6.3A
6.3A
6.3A
6.3A
=TB/3
I>
K7A,B,C
=TB/4
Generator
Fan Cooling
Circuit 1
Hydraulic
Pump
=TB/3
K5
=TB/4
I>
=TB/3
=TB/3
I>
K14
=TB/6
Q15
Q16
Q17
Q18
10A
10A
10A
10A
=TB/6
=TB/6
=TB/6
I>
K10
=TB/6
I>
K12
I>
K11
=TB/6
=TB/6
=TB/6
I>
K13
=TB/6
I>
Shorting
Contactor
Yaw
Motor 1
3
previous
REV
DESCRIPTION
CHECKED BY
REVISED BY
12-MAR-2009 12-MAR-2009
J. Chacon
R. Shaw
Yaw
Motor 2
Yaw
Motor 3
GE Energy
DRAWN
ISSUED
25-APR-7008
DWB
G. Stultz
Yaw
Motor 4
Gearbox
Lubricating
Pump - Low
Speed
Top Box
690 V Power
One Line Drawing
Gearbox
Lubricating
Pump - High
Speed
Gearbox Oil
Cooler High Speed
Gearbox Oil
Cooler Low Speed
COMPONENT
1.6 xle
5 next
= OneLines
+
TYPE
COMP-DRW. NO.
COMP-PART NO.
107W5365
REV
Sh
of
4
8
400/230V
from DTA
Q32
=CFC/3
Q19A,B,C
Surge
Suppressor
3A
13A
=TB/15
=TB/7
F5
=TB/7
Q20
Q22
1A
3A
=TB/7
J6
K7
=TB/7
3A
3A
J1
J21
J1
K14
K1
J3
=TB/8
Internal
TB Fans
=TB/10
Q26
3A
=TB/9
Yaw Lube
Pump
=TB/7
Q25
=TB/10
P39
Slip Ring
Heater
Q24
=TB/8
K18
J20
400/230V
to Pitch
System
Q23
3A
=TB/10
K2
J4A,B,C,D
=TB/10
J1
J1,J6,J21
=TB/27
J19
WETA
K3
J8
500VA
230V/24v
6A
=TB/8
J21
WETB
T4
Q27A,B,C
K4
J8
K5
J8
Yaw
Motor
Heaters
Gbx Lube
Pump
Heater
Hydraulic
Pump
Heater
Gbx Lube
Pump
Exchanger
=TB/9
=TB/9
=TB/9
=TB/9
P6
J4A,B,C,D
Heat Pipe
=TB/10
FU3,4,5
K10,11,12
A,B
K17
P19,20,21
J2A,B,C
Yaw
Motor
Brakes
Internal
Heaters
=TB/8
=TB/10
Wind
Vane
Heater
=TB/27
Q28
3A
=TB/7
J6
230V UPS
from DTA
WETB
FU6
J17
=MCC/5
UPS / Heater
Control
Power Supply
K21
J18
T2
300 W, 24VDC
Power Supply
=TB/12
4
previous
REV
DESCRIPTION
CHECKED BY
REVISED BY
12-MAR-2009 12-MAR-2009
J. Chacon
R. Shaw
T3
600 W, 24VDC
Power Supply
=TB/12
GE Energy
DRAWN
ISSUED
25-APR-7008
DWB
G. Stultz
Top Box
400/230 V Power
One Line Drawing
COMPONENT
1.6 xle
6 next
= OneLines
+
TYPE
COMP-DRW. NO.
COMP-PART NO.
107W5365
REV
Sh
of
5
8
DTA
WEMA
AEAD
P24
WEMA
WEMA
S1
=MCC/16
P24_SFTY
Filter
WEMA
AEAD
=MCC/12,13
P7-5
P1-3
P7-2
18K3
Trip Safety
Loop
grn
P7-1
P1-2
K9
P6-2
12
P6-1
11
=MCC/14
TB2-17
.7
Seal-In
Relay
J1
DIN9
8K1
DTA
Estop
/7.1
18K3
AEAD
=MCC/11
P1-5
X6.1-6
MFR Grid
Monitor OK
MACC
P7-6
TB2-18
Hardware
Drop-Out
Delay
Digital
Input
J1
AEAD-K1
AEAD-K2
Q1 UV
Trip
Synchronization
Switch
Pilot Relay
PCOM
WETB
X4.1-30
P10-5
1 3
=TB/29
WETC
K11
Rotor
Overspeed
WETA Comm
OK
13K1
WETB
P12-2
P41C-2
P41B-2
13K1
P13-1
12S1
P12-1
K13
1A
WETB Comm
OK
WDOGA
P13-2
P41B-1
P41C-1
K1
WETC Comm
OK
EStop
WETB
S6
WETB
1B
Top Box
Estop
/7.4
WDOGB
WETB
P14-1
12S4
P14-2
P10-1
12K3
X4.1-28
X6.1-4
P1-1
P6-10
3 1
=TB/29
Hub EStop
/7.8
Rotor
Blocking
Clear
Vibration
Switch
WEMA
EstHub
P16-1
P15-1
3
S7PB
Stop/Reset
Top Box
24
EXTS7
S7
18S2.1
8K1
8K2
External
Stop/Reset
.7
Seal-In
Relay
Time Delay
Reset
P15-2
S2
Stop/Reset
DTA
23
P16-2
P10-2
X4.1-28
X6.1-3
P1-2
P6-9
4 2
=TB/29
12K2
8K1
12K2
8K1
Safety Loop to
Pitch and
Brake Valves
Safety Loop
Closed
P10-3
X4.1-29
X6.1-2
P1-3
3 1
=TB/29
Top Box
5
previous
REV
DESCRIPTION
WETB
CHECKED BY
REVISED BY
12-MAR-2009 12-MAR-2009
J. Chacon
R. Shaw
GE Energy
DRAWN
ISSUED
25-APR-7008
DWB
G. Stultz
PCOM
COMPONENT
1.6 xle
7 next
= OneLines
+
TYPE
COMP-DRW. NO.
COMP-PART NO.
107W5365
REV
Sh
of
6
8
DTA
Top Box
DTA
WEMA
P24_SFTY
S1
P6-4
22
WEMA
P6-3
21
S6
WETB
P1-4
X6.1-7
P10-4
X4.1-29
2 4
=TB/29
DTA
Estop
/6.3
P12-3
12K3
1B
Hub EStop
.8
WETB
2B
Top Box
Estop
/6.4
-EstHub
P12-4
WETC
K13
P41C-3
P41B-3
WETB Comm
OK
WETB
P41C-4
K1
P41B-4
WETC Comm
OK
-WDOGB
WEMA
13K3
K11
WETA Comm
OK
-EStop
P10-6
X4.1-30
X6.1-1
P1-6
4 2
=TB/29
Contactor Driver
Enable
PCOM
.7
-WDOGA
WETB
=TB/13
P24
P24SW
13K3
Contactor Driver
Enable
.7
Note: P24SW powers most
contact outputs in the Top Box.
Top Box
Slipring
Slipring
Top Box
All circuits shown on
=TB/17
WETB
AEPC
PP24
J16-1
X4.1-14
J16-2
6 5
=TB/29
SR5
TB1-1
AEPC
J6-1
J6-2
AEPC
J6-5
Hub
Estop
JX-C4
JX-C1
J6-8
WETB
TB1-6
SR12
P9-4
ePALM
Estop
12K3
/6.3
.3
Hub EStop
Man/Auto
Selector Switch
PCOM
Manual = Open
Auto = Closed
6
previous
REV
DESCRIPTION
CHECKED BY
REVISED BY
12-MAR-2009 12-MAR-2009
J. Chacon
R. Shaw
GE Energy
DRAWN
ISSUED
25-APR-7008
DWB
G. Stultz
COMPONENT
1.6 xle
8 next
= OneLines
+
TYPE
COMP-DRW. NO.
COMP-PART NO.
107W5365
REV
Sh
of
7
8
green
5
3
1
=MCC/6
UCSA
3
1
Enet1
6
4
2
Enet1
A3
Enet2
USB
COM
N-Tron
508FX2
fiber connections
N-Tron
509FX
Enet2
A4
N-Tron
508TX-A
Enet2
ES
green
copper connections
copper connections
J4
J4
J4
BPPB
BPPB
BPPB
=AXS1/7
=AXS2/7
=AXS3/7
AEPA
AEPA
AEPA
=AXS1/4-7
=AXS2/4-7
=AXS3/4-7
fiber connections
green
8
copper connections
Hub
Main Control
Pitch Drives
=PSCB/8
7
I/O Net
J4
BPPB
Down-Tower
Assembly
5
3
1
6
4
Top Box
Enet2
A1
N-Tron
509FX-A
RJ45
Discrete Components
Digital Inputs
Contactors
Environmental Control
=TB/13
green
7
copper connections
=MCC/4-10
fiber connections
I/O Net
WEMA
Serial
Serial
J4
BPPB
I/O Net
=TB/13
Power Converter
AEAD
=MCC/20
MACC
AEAA
DC Bus
=TB/13-15,18-22
PT100 Temperature
4-20mA Analog Ins
Prox Switches
Rotor Converter
IGBTs
AEBM
AEBI 2
=MCC/11
=MCC/17,18
WETC
=TB/7-10,13-17
=MCC/20
BPPB
Power Controls,
Contactors,
Voltage/Current
Sensing
WETB
=TB/13-15,23-28
Line Converter
IGBTs
AEBM
AEBI 1
J4
=MCC/12-16
WETA
=MCC/21
Discrete Components
Digital Inputs
Contactors
Environmental Control
Wind Vane /
Anemometer
Vibration Sensors
=MCC/21
Nacelle
WEOR
AEPS
=MCC/22
=MCC/19
230 VAC
7
previous
REV
DESCRIPTION
=PDC/1
CHECKED BY
REVISED BY
12-MAR-2009 12-MAR-2009
J. Chacon
R. Shaw
GE Energy
DRAWN
ISSUED
25-APR-7008
DWB
G. Stultz
COMPONENT
1.6 xle
next
= OneLines
+
TYPE
COMP-DRW. NO.
COMP-PART NO.
107W5365
REV
Sh
of
8
8
BioEnergy
Component:
Comp No.:
Comp-Drw. No.:
Comp-Part No.:
107W4611
107W5379P001
MAIN
TRANSFORMER
GEN
STATOR
GEN
ROTOR
690 V
690 V
690 V
50/60 Hz
50/60 Hz
50/60 Hz
1430
1400
640 MAX
=OneLines/8
previous
REV
DESCRIPTION
Updated Converter
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
R. Shaw
J. Curtis
GE Energy
DRAWN
ISSUED
26-MAR-2009 G. Stultz
DWB
2
DATE
SIGNATURE
ENGINEER
26-MAR-2009 A. Klodowski
DRAWN
26-MAR-2009 G. Stultz
CHECKED
26-MAR-2009 A. Klodowski
ISSUED
DWB
next
GE Energy
COMPONENT
TYPE
1.6 xle
= PDC
+
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
Sh
of
1
7
revision
03/26/09
New Release
07/23/09
3, 5, 24
11/03/09
4, 5
Updated Converter
change
date
1
previous
REV
DESCRIPTION
page
actual state
3
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= PDC
+
Sh
of
2
7
-CT1
L1
690V
from
Main
Transformer
L2
P2
s2
9
4.0
P1
-CT2
s1
1500:5
10VA, 0.5%
P2
s2
L3
BUSBAR
L1B
BUSBAR
L2B
BUSBAR
L3B
BUSBAR
PEN
4.0
P1
-CT3
s1
1500:5
10VA, 0.5%
P2
s2
PEN
4.0
P1
6.0
s1
1500:5
10VA, 0.5%
L1
-FU1A
L2
-FU1B
355A
690V
355A
690V
T1
L3
-FU1C
T2
355A
690V
T3
6.0
BUSBAR
L1
6.0
BUSBAR
L2
6.0
BUSBAR
L3
BUSBAR JUMPER
BUSBAR JUMPER
BUSBAR JUMPER
1
=MCC/12.0 / CT3-k
=MCC/10.3 / CT3-l
=MCC/12.0 / CT2-k
=MCC/10.3 / CT2-l
=MCC/12.0 / CT1-k
=MCC/10.3 / CT1-l
L1
L2
L3
L1
-FB1
-FB2
200A
100A
T1
T2
T3
T1
L2
L3
T2
T3
43
43
-Q15
-Q15
-Q16
-Q16
.7
.16-.25A
fuse
monitor
44 .6
.8
.16-.25A
fuse
monitor
44 .7
12
-F4
.5
11
12
-F5
.5
11
12
-F6
.5
Surge Suppressor
Circuuits
-F1
-F2
-F3
Spark
Gap
2 Spark
Gap
2 Spark
Gap
-F4
2
.8
Solid
State
-F5
.8
Solid
State
-F6
.8
Solid
State
WEMAP14-1
=MCC/5.2
shortest connection
to PE busbar
-PEN
2
previous
REV
DESCRIPTION
Updated Converter
11
shortest connection
to PE busbar
Enclosed Devices
Power must be
removed before
servicing
DTAK2A1
=MCC/5.2
-PEN
4
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= PDC
+
Sh
of
3
7
3.9
L1B
=CFC/5.0
L1
T1
L1A
T1
L1
L2
T2
L2A
T2
L2
L3
T3
L3A
T3
L3
L1D
3.9
L2B
=CFC/5.0
L2D
3.9
L3B
=CFC/5.0
-Q1
L3D
-K1
2000A
Motor
Operated
/7.6
-PDC_AUX
(Other Devices See One Lines)
L1
L2
L3
-Q6
0.63-1A
(1A)
=MCC/18.3 / AEAAP4-L3
=MCC/18.3 / AEAAP3-L2
T2
=MCC/18.2 / AEAAP2-L2
=MCC/18.1 / AEAAP1-L1
5.0 / CONVL3A
5.0 / CONVL2A
5.0 / CONVL1A
T1
Stator Voltage
Feedback to AEAA
3
previous
REV
DESCRIPTION
Updated Converter
5
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= PDC
+
Sh
of
4
7
PDCAUX-Q5-T3 / 6.9
PDCAUX-Q5-T2 / 6.8
PDCAUX-Q5-T1 / 6.8
HTR7-1 / =CFC/5.9
-HTR7
250W
-HTR8
250W
L1
L2
L3
T1
T2
T3
=MCC/5.4
-CCR1
50 Ohms
500W
-CCR2
1
50 Ohms
500W
=CFC/5.9 / HTR7-2
CCONT
-CCR3
1
50 Ohms
500W
350A
690V
4.4
CONVL3A
4.4
CONVL2A
4.3
CONVL1A
4
previous
REV
DESCRIPTION
Updated Converter
-ACLFU3
1
=CFC/6.0
ACLFU3-2
-ACLFU2
1
=CFC/6.0
ACLFU2-2
-ACLFU1
1
=CFC/6.0
ACLFU1-2
6
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= PDC
+
Sh
of
5
7
3.9
L1
Bus Jumper
Bus Jumper
Bus Jumper
Bus Jumper
Bus Jumper
Bus Jumper
3.9
L2
3.9
L3
3.9
PEN
PEN
-PDC_AUX
T2
40A
NH 0
T3
T1
T2
Updated Converter
L3
L1
-Q2
-Q3
-Q5
0.63-1A
(1A)
0.63-1A
(1A)
T3
T2 Feed For
Aux/Control Power
400/230V
208/120V
173/100V
=MCC/16.5 / AEADP3
=CFC/3.0 / T2-H3
=CFC/3.0 / T2-H2
=CFC/3.0 / T2-H1
=MCC/10.8 / PDCAUX-FB3-T3
=MCC/10.8 / PDCAUX-FB3-T2
=MCC/10.7 / PDCAUX-FB3-T1
5
previous
REV
DESCRIPTION
L2
0.63-1A
(1A)
T1
L1
T2
T3
Voltage Feedback to
Frequency Converter for
grid monitor Function
(AEAD)
T2
L2
L3
T3
T1
T2
T3
5.3 / PDCAUX-Q5-T3
T1
L3
5.2 / PDCAUX-Q5-T1
-FB4
L2
=MCC/10.6 / PDCAUX-Q3-T3
80A
L3
=MCC/10.5 / PDCAUX-Q3-T2
-FB3
L2
=MCC/10.5 / PDCAUX-Q3-T1
L1
=MCC/16.5 / AEADP7
L3
=MCC/16.5 / AEADP5
L2
5.3 / PDCAUX-Q5-T2
L1
L1
7
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= PDC
+
Sh
of
6
7
=MCC/14.2
AEADP11
=MCC/14.2
AEADK1COM
AEADTB1-8 / =MCC/13.4
AEADTB1-7 / =MCC/13.3
-K1
A1
D1
D2
84
81
/4.5
Contactor LC1F780
Internal Coil Circuit
-Q1
-Q1
-Q1
-Q1
Motor
Operation
230VAC
Closing
Coil
230VAC
UV
Coil
24VDC
BELL ALARM
-Q1
6
previous
REV
DESCRIPTION
Updated Converter
A2
=MCC/22.9 / DTAK1-A2
A1
=MCC/22.9 / DTAK1-A1
=MCC/15.3
A2
AEADK6COM
B2'
AEADK6NO
=MCC/15.3
DTAQ1B2
=MCC/5.3
DTAQ1N
=MCC/5.3
B2
B1'
B1
=CFC/1
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= PDC
+
Sh
of
7
7
BioEnergy
Component:
Comp No.:
Comp-Drw. No.:
Comp-Part No.:
107W4611
107W5379P001
MAIN
TRANSFORMER
GEN
STATOR
GEN
ROTOR
690 V
690 V
690 V
50/60 Hz
50/60 Hz
50/60 Hz
1430
1400
640 MAX
Uodated Converter
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
R. Shaw
J. Curtis
GE Energy
DRAWN
ISSUED
26-MAR-2009 G. Stultz
DWB
2
DATE
SIGNATURE
ENGINEER
26-MAR-2009 A. Klodowski
DRAWN
26-MAR-2009 G. Stultz
CHECKED
26-MAR-2009 A. Klodowski
ISSUED
DWB
next
GE Energy
COMPONENT
TYPE
1.6 xle
= CFC
+
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
Sh
of
1
6
date
revision
change
New Release
07/23/09
3, 5, 24
11/03/09
4, 5
Updated Converter
page
03/26/09
1
previous
REV
DESCRIPTION
actual state
3
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= CFC
+
Sh
of
2
6
=PDC/6.4 / T2-H3
=PDC/6.4 / T2-H2
=PDC/6.4 / T2-H1
-T2
690 V
32.5 KVA Transformer@ 40 degrees C
400V Tower Hoist Connections
X1
X2
H1
H2
T2
X3
X1
X2
H3
X0
X3
X0
Chassis
X4
X5
X6
X7
X8
X9
=MCC/23.0 / T2-X1
Optional
Connection
for 400Vac
=MCC/23.0 / T2-X2
=MCC/23.0 / T2-X3
230L1
230L1
230L2
230L2
PDCAUX-Q12-L1
230L3
PDCAUX-Q12-L2
PDCAUX-Q12-L3
=MCC/23.0
=MCC/23.0
230L3
=MCC/23.0
T2 Shelf
-PDC_AUX
(Other Devices See One Lines)
-X3.3
1
1(1)
-Q13
20A
=MCC/7.2
-Q8
2
30A
L1/L2 Shelf
1(2)
-PEN
-MCC
2
previous
REV
DESCRIPTION
Updated Converter
=MCC/23.0 / PDCAUX-Q11-1
=MCC/23.0 / PDCAUX-Q10-1
=MCC/23.0 / PDCAUX-Q9-1
=MCC/23.0 / PDCAUX-Q20-1
=MCC/23.0 / PDCAUX-Q19-1
=MCC/23.0 / PDCAUX-Q18-1
=MCC/24.3 / Q8-6
-PEN
=MCC/24.3 / Q8-4
=MCC/24.3 / Q8-2
=TB/7.0 / DTA400PE
=TB/7.0 / DTA400N
=TB/7.0 / DTA400T3
=TB/7.0 / DTA400T1
=TB/7.0 / DTA400T2
-X3.2
4
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= CFC
+
Sh
of
3
6
M.6.3
M.6.2
=GE/5.5
=GE/5.5
M.6.1
=GE/5.5
OPTION 1
L.6.3
L.6.2
OPTION 1
OPTION 1
-PEN
=GE/5.4
=GE/5.4
L.6.1
=GE/5.4
K.6.3
K.6.2
=GE/5.3
=GE/5.3
1
K.6.1
=GE/5.3
Gnd
=GE/5.2
1PE.6.2
ROTOR
0.5 uF
22 Ohms
-ROVC 1
0.5 uF
22 Ohms
-ROVC 2
B2
A2
ROTOR
0.5 uF
22 Ohms
-ROVC 3
C2
-L2
25uH
750A
B1
A1
C1
3
previous
REV
DESCRIPTION
Updated Converter
ROVC3-2
=MCC/14.8
6.7
ROVC3-1
=MCC/14.8
CONV-L2-C1
=CBC/5.8
CONV-L2-B1
=CBC/5.7
CONV-L2-A1
=CBC/5.3
.4
L1 Chassis
5
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= CFC
+
Sh
of
4
6
=PDC/4.9
-CT4
L1D
P2
s2
STATOR
P1
1L1.6.1 / =GE/4.1
s1
1500:1
5VA, 0.5%
1L1.6.2 / =GE/4.1
1L1.6.3 / =GE/4.1
=PDC/4.9
-CT5
L2D
P2
s2
1L1.6.4 / =GE/4.1
OPTION 1
P1
1L2.6.1 / =GE/4.2
s1
1500:1
5VA, 0.5%
1L2.6.2 / =GE/4.2
1L2.6.3 / =GE/4.2
1L2.6.4 / =GE/4.2
OPTION 1
-CT6
P2
P1
1L3.6.1 / =GE/4.3
s1
1500:1
5VA, 0.5%
-PEN
-PEN
1L3.6.2 / =GE/4.3
WEMAK15-COM / =MCC/4.2
s2
1L3.6.3 / =GE/4.3
1L3.6.4 / =GE/4.4
OPTION 1
GND
1PE.6.1 / =GE/4.4
-PEN
HTR5-1 / =MCC/4.8
L3D
WEMAK14-COM / =MCC/4.2
=PDC/4.9
-OT
KLIXON
=PDC/5.6
HTR7-1
-HTR1
1500W
2 Coolant Heater
-PEN
=MCC/24.6
=MCC/17.3 / AEAATB3-66
=MCC/17.3 / AEAATB3-65
=MCC/17.2 / AEAATB3-64
=MCC/17.2 / AEAATB3-63
-GND
=MCC/17.1 / AEAATB3-62
HTR1-2
=MCC/17.1 / AEAATB3-61
-PAS0
100
-M1
230 Vac 1 PH
60 Hz
11 A
PUMP MOTOR
0.5ufd
-HTR5
250W
=MCC/24.3
-HTR6
250W
2
PUMP-M1-4
M
1~
-J
=PDC/5.6
HTR7-2
2 3
-PEN
STATOR
=MCC/24.6 / HTR5-2
4
previous
REV
DESCRIPTION
Updated Converter
6
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= CFC
+
Sh
of
5
6
L1
L2
L3
T1
T2
T3
KDF
=MCC/15.2
CONV-L1-C1 / =CBC/3.8
CONV-L1-B1 / =CBC/3.8
-L1
150H 375A
ELEMENTS STAMPED
WITH PSG 104
-LFR3D
-LFR3B
-LFR3C
-LFR3A
-LFR2D
-LFR2B
-LFR2C
-LFR2A
-LFR1D
-LFR1B
-LFR1C
-LFR1A
0.027Ohms each
CONV-L1-A1 / =CBC/3.8
-LFC
65KVAR
600V 60Hz
NOMINAL CAP.
VALUE=160 uF
NOMINAL RES.
VALUE=100K
71.8 KVAR
690V 50Hz
A2
B2
C2
A1
B1
C1
chassis
=PDC/5.9
L1 Chassis
4.2
L1/L2 shelf
ACLFU3-2
=PDC/5.9
ACLFU2-2
=PDC/5.9
ACLFU1-2
5
previous
REV
DESCRIPTION
Updated Converter
=MCC/1
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= CFC
+
Sh
of
6
6
BioEnergy
Component:
Comp No.:
Comp-Drw. No.:
Comp-Part No.:
107W4611
107W5379P001
MAIN
TRANSFORMER
GEN
STATOR
GEN
ROTOR
690 V
690 V
690 V
50/60 Hz
50/60 Hz
50/60 Hz
1430
1400
640 MAX
Uodated Converter
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
R. Shaw
J. Curtis
GE Energy
DRAWN
ISSUED
26-MAR-2009 G. Stultz
DWB
2
DATE
SIGNATURE
ENGINEER
26-MAR-2009 A. Klodowski
DRAWN
26-MAR-2009 G. Stultz
CHECKED
26-MAR-2009 A. Klodowski
ISSUED
DWB
next
GE Energy
COMPONENT
TYPE
1.6 xle
= MCC
+
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
Sh
of
1
25
date
revision
change
New Release
07/23/09
3, 5, 24
11/03/09
4, 5
Updated Converter
page
03/26/09
1
previous
REV
DESCRIPTION
actual state
3
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
2
25
24.3 / Q14-L1
24.3 / Q14-L2
24.3 / Q14-L3
L1
L2
L3
-Q21
2.5-4A
(2.5A)
15.7
AEADK8NO
15.8
AEADK8COM
-K5
.7
T1
T2
T3
-W2
rd
bl
bk
-X3.4
1(1)
2(1)
3(1)
-X3.4
-W1
-X3.2
-X3.2
6(1)
7(1)
8(1)
9(1)
1(2)
bn
7(2)
8(2)
bl
-Fan1
L1
9(2)
L2
rd
gy
-X3.1
22(2)
-X3.4
5(1)
-X3.4
5(2)
-W1
bk
-W2
ye/gr
gr/bk
L3
M
3~
-W1
22(1)
wh/bk
3(2)
-W1
-PEN
Main DTA
Ventilator Fan
400vac 3 ph
50 Hz 2.3A
60 Hz 2.5A
6(2)
2(2)
-X3.1
-X3.1
21(2)
-X3.1
21(1)
wh
-Fan1
.5
(OT Switch)
-W1
wh
-X3.4
6(2)
-X3.4
6(1)
-W2
wh
or
-K5
Chassis
A1
Sup
Spare
-PEN
A2
T1 .5
T2 .5
T3 .6
K5-A2
24.6
2
previous
REV
DESCRIPTION
Updated Converter
4
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
3
25
-WEMA
K1-NO
K2-NO
-K1
-K2
L2
230Vac
L3, 230VAC
24.6
24.6
WEMA-K13-NC
L2
230Vac
24.6
24.6
24.6
WEMA-K14-NO
24.3
L2
230Vac
K14-NO
K15-NO
15.5 / AEADK7NO
L1
230Vac
WEMA-K15-NO
L3
230Vac
WEMA-K3-NO
WEMA-K2-NO
WEMA-K1-NO
K3-NO
K13-NC
-WEMA
J10-1
-K15
-K14
-K13
-K3
J10-3
15.5 / AEADK7COM
HTR2
HTR1
(Coolant Heater)
K3-COM
HTR3
K13-COM
=CFC/5.8 / HTR5-1
=CBC/6.5 / WEMAK1-COM
=CFC/5.5 / WEMAK14-COM
=CFC/5.5 / WEMAK15-COM
(PUMP)
K2-COM
=CBC/6.9 / WEMAK3-COM
K1-COM
K14-COM
=CBC/6.7 / WEMAK2-COM
K15-COM
HTR4
Updated Converter
5
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
4
25
L1
L2
L3
44
A2
-CCONT
21
-KDF
22 /15.2
22.2
WEMA-J5B-N
22.2
A2
WEMA-J5B-L
Sup
-K2
DTAQ1N / =PDC/7.0
A1
T1 =PDC/5.2
T2 =PDC/5.3
T3 =PDC/5.3
A1
DTAQ1B2 / =PDC/7.1
=PDC/3.7
WEMAP14-1
WEMA-J9-4 / 24.6
=PDC/3.9
Neut.
Sup
Q22-1 / 24.3
L1
230Vac
DTAK2A1
43 /7.0
Q1
-J5C-3-
-J5C-2-
L1
-J5C-1-
-J5B-3-
-J5B-2-
-J5B-1-
-J5A-3-
-J5A-2-
-J5A-1-
-J9-4-
-P14-1-
2
-J9-1-
16A
-P14-4-
-Q22
-A2
WEOR
-K4
-UPS
NOT
OK
230VAC
UPS
230Vac
-J5-1-
ENV OK
Input plug
Neutral
-LOW
BATTERY
-J5-3-
PE
UPSL
J7
3
red
wht
J8
3
grn
blk
A2-J7-3 / 7.1
A2-J7-1 / 7.1
A2-J8-1 / 7.2
A2-J8-3 / 7.2
UPSN
-WEMA
Output plug
-WEMA
K4 Relay (ENV OK) is turned on when any of the following conditions are met:
-MCC cabinet temperature> 5 deg C for a 70 minutes heat-soak delay time
-MCC cabinet temperature> 45 deg C for 10 minutes
-Pushing and holding S2 (Stop/Reset Pushbutton- WEMA Din29) for 5 seconds
-PEN
1
-Q23
16A
-X4.1
1(1)
2(1)
3(1)
4(1)
-X4.1
1(2)
2(2)
3(2)
4(2)
-T3
24V DC
12A
Power
Supply
via UPS
(+)
J7-1
(+)
J7-2
(-)
J7-3
(-)
J7-4
-PEN
-PEN
=TB/29.9
24.3
UPSN-J1
=TB/29.9
-X4.1
5(1)
-X4.1
5(2)
DTA 230 UPS PE / =TB/29.9
Updated Converter
6
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
5
25
-A3
-WEMA
P2-1
P2-3
+24Vdc
IN2
V1(+)
Fiber
Optic
OUT2
IN
COM
V1(-)
OUT
ENET Switch 1
SCADA
EXTERNAL
SOURCE
24VDC
FIELD SERVICE
CONNECTION
SCADA
OPTIONAL FIELD
CONNECTIONS
EXTERNAL
SOURCE
24VDC
3
ENET
RJ45
-S4
-FE
-S5
-UCSA
P5-1
P5-3
+24Vdc
COM
P12-1
Enet1
P12-3
-X6.1
11(2)
12(2)
13(2)
14(2)
8(2)
9(2)
10(2)
-X6.1
11(1)
12(1)
13(1)
14(1)
8(1)
9(1)
10(1)
-TB4
-FE
Din 15
External
Stop
-A4
P2-2
+24Vdc
IN
Fiber
Optic
V1(+)
Fiber In / =TB/13.2
P2-4
Din 14
Locking
Mains
On
OUT
COM
-WEMA
-K6
Uptower
to
TOPBOX
V1(-)
ENET Switch 2
IONET
Chassis
DO 06
1
ENET
RJ45
MACC_BPPBJ4 / 11.4
J4
-FE
5
previous
REV
DESCRIPTION
Updated Converter
-FE
-PEN
7
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
6
25
P8-4
P8-3
P8-2
P8-1
P8-16
REPAIR
DIN 02
MAINTENANCE
DIN 01
IDLE / RESET
DIN 13
P8-15
P8-14
P8-13
P8-12
YAW
START
DIN 08
YAW MANUAL /
AUTOMATIC
DIN 07
P8-11
P8-10
P8-9
P8-8
BUTTON
YAW STOP
DIN 06
YAW RIGHT
DIN 05
P8-7
P8-6
P8-5
P12-4
YAW LEFT
DIN 04
CONTROL
BREAKER
STATUS (3)
DIN 33
P12-5
P12-6
P12-3
P12-2
CONTROL
BREAKER
STATUS (2)
DIN 27
P11-6
BATTERY
LOW POWER
DIN 12
P11-5
P11-4
UPS OK
DIN 11
P11-3
P11-2
44
23
-K2
/5.2
SPARE
DIN 10
P11-1
P9-2
P9-1
OVERVOLTAGE
PROTECTION /
LIGHTNING
SUPERVISION
DIN 09
-WEMA
-Q13
43
24
=CFC/3.0
5.7 / A2-J8-3
5.7 / A2-J8-1
5.7 / A2-J7-1
23
5.7 / A2-J7-3
Surge
Suppressor
Status
-S7
-PDC_AUX
Top Box
400 Vac
Status
24
Updated Converter
14
Yaw/Stop
13
-S9
24
24
13
-S10
14
Yaw/Manual
14
Start
Idle
Reset
24
14
-S6
UPS
Status
6
previous
REV
DESCRIPTION
23
-S8
Yaw
SELECTOR SWITCH
LEFT
OFF
RIGHT
23
13
23
13
-S11
KEY SWITCH
O = OPERATE
I = Service
II = REPAIR
8
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
7
25
24
12
DTA ESTOP
Switch
(door mounted)
12
22
14
16.2
-X6.1
1(2)
2(2)
3(2)
4(2)
-X6.1
1(1)
2(1)
3(1)
4(1)
-P1-6-
-P1-3-
-P1-2-
-P1-1-
-P7-6-
AEADP1-3
AEADP1-2
WETBP10-1
=TB/29.7
=TB/29.8
WETBP10-2
=TB/29.8
=TB/29.8
WETBP10-6
AEAA1 K9
GRID MONITOR OK
13
-P6-10-
-P6-12-
-P6-11- -P6-9-
-P7-1-
=TB/29.8
21
WETBP10-4
11
-S1
=TB/29.8
11
To Top Box
Safety Chain Reset
WETBP10-3
0V TO
TOP BOX
AEADTB2-18 / 13.8
AEADTB2-17 / 13.7
STOP/
RESET
(Door Mounted)
-P7-5-
23
-S2
16.1
Safety String
to converter
WETBP10-5
GND
-PEN
-P7-2-
-P6-2-
-P6-4-
-P6-6-
-P6-5-
-P6-3-
-P6-1-
6(2)
7(2)
5(2)
6(1)
7(1)
5(1)
-P1-5-
-P1-4-
-18K3
-8K1
-P24_PIC
.6
-P24_SFTY
PCOM
-8K2
.3
.3
.5
-8K2
-8K1
Seal-In
Relay
Contacts
-18K3
DO_08
DIN 32
.1
.3
DIN 29
STP/RST
-8K1
DO_11
Yel
GRN
PIC
Push Button
Stop/Reset
GRN
DIN 28
GRN
COM
COM
BPPB
ESTOP
DIN 29
Yel
Push Button
Stop/Reset
Safety
Loop
Closed
GRN
RED
DIN 28
Trip Safety
Loop Control
Overide
E-STOP
Activated In
Control Cabinet
Yel
PCOM
-WEMA
7
previous
REV
DESCRIPTION
Updated Converter
9
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
8
25
OPTIONAL
TEMPERATURE
MONITORS
-R2
P4-1
OPTIONAL
DIFFERENTIAL
RELAY DRY- CONTACT INPUTS
-R1
P4-3
P3-2
Therm 2
P3-1
P10-4
Therm 1
P10-3
DIN 17
P10-2
P10-1
DIN 16
P13-2
P13-1
DIN 22
-TB2
DIN 21
DIN 20
-TB1
DIN 19
DIN 18
-WEMA
8
previous
REV
DESCRIPTION
Updated Converter
10
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
9
25
-X2.1
1(1)
2(1)
=PDC/6.3
PDCAUX-FB3-T3
=PDC/6.3
PDCAUX-FB3-T2
TEST SOCKET 4
=PDC/6.2
3(1)
PDCAUX-FB3-T1
TEST SOCKET 3
=PDC/6.7
TEST SOCKET 1
-WEMA
PDCAUX-Q3-T3
TEST SOCKET 2
=PDC/6.7
PDCAUX-Q3-T2
=PDC/6.7
PDCAUX-Q3-T1
-PEN
4(1)
5(1)
6(1)
7(1)
8(1)
9(1)
10(1)
11(1)
12(1)
13(1)
9(2)
10(2)
11(2)
12(2)
13(2)
-X2.1
K7
DO 07
-TB3
K9
DO 09
2
1(2)
2(2)
3(2)
4(2)
5(2)
6(2)
7(2)
8(2)
K10
DO 10
4
-Q24
Neut.
L2, 230Vac
24.3 / Q24-1
230
Vac
2
6A
V1
Neutral
24.3 / MCC10
V2
V3
GND
I1
-TB1
-TB1
PEA
PEB
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
I2
I3
Contents
within
dotted box
not supplied
=PDC/3.1 / CT1-l
12.0 / TB1-2A
12.0 / TB1-6A
9
previous
REV
DESCRIPTION
Updated Converter
=TB/3.0 / DTA690PEN
=PDC/3.2 / CT3-l
=TB/3.0 / DTA690T3
12.0 / TB1-4A
=TB/3.0 / DTA690T2
=TB/3.0 / DTA690T1
=PDC/3.1 / CT2-l
11
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
10
25
MACCP2 / 21.9
P2
MACCH1
P8
J2
Updated Converter
-TB1
12 11 10 9 8 7 6 5 4 3 2 1
TACHOMETER
E2
+24
+24 / =GE/10.4
COM
Com / =GE/10.5
/M
M
/B
B
/A
A
K0q / =GE/10.4
K0 / =GE/10.3
K1q / =GE/10.3
K1 / =GE/10.3
K2q / =GE/10.3
K2 / =GE/10.3
SHLD
Shld / =GE/10.5
J7-2
J7-3
J7-4
J7-5
J7-6
J7-7
J7-8
19.1 / AEPSP1-2
19.1 / AEPSP1-3
19.1 / AEPSP1-4
19.1 / AEPSP1-5
19.1 / AEPSP1-6
19.1 / AEPSP1-7
19.1 / AEPSP1-8
17.6 / MACCJ2
J7-1
19.0 / AEPSP1-1
J7
J2
E3
J1
12.7 / MACCJ1
J4
J6
BPPB
POWER
RJ45 RJ45
E6
10
previous
REV
DESCRIPTION
J3
BPPB
POWER
1 P1
BPPB
J1
P7
IS200
-WECA
E5
E4
E1
P1
6.4
MACC_BPPBJ4
MACCP1 / 20.8
12
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
11
25
CCOM
CCOM3
J1
2B
3A
3B
4A
4B
5A
5B
6A
6B
PEA
PEB
P18-1
P18-2
P18-3
11.3 / MACCJ1
2A
19.6 / AEPSP18A1-3
1B
19.6 / AEPSP18A1-2
1A
Chassis
19.6 / AEPSP18A1-1
Chassis
=PDC/3.1
CT1-k
E5
CP24
CN24
CCOM
E4
-TB2
10.3
I1
30
29
28
27
26
25
-TB3
-TB2
TB1-2A
E4
E4
E4
I/O 1
IS200AEAD_H1A
-AEAD
0.05
0.05
0.05
10.3
TB1-4A
Grid
Current
I2
Feedback
=PDC/3.2
CT2-k
10.3
TB1-6A
I3
11
previous
REV
DESCRIPTION
Updated Converter
=PDC/3.3
CT3-k
13
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
12
25
18
17
16
15
14
13
-TB2
12
11
10
-TB1
I/O 1
IS200AEAD_H1A
-AEAD
13
-KDF
AEADTB2-18
8.2
POWER
ENABLE
AEADTB2-17
8.1
BRIDGE
-TH4
COOLANT
INLET
TEMPERATURE
CFC
-TH3
TEMPERATURE
=PDC/7.4 / AEADTB1-8
Q1 BELL
ALARM
-TH2
PDC
TEMPERATURE
=PDC/7.4 / AEADTB1-7
14
degC
-40
-30
-20
-10
0
10
20
25
30
40
50
60
TH1,TH2,TH3,TH4
336487
177071
97139
55359
32671
19909
12494
10000
8056
5325
3602
2488
Inlet Air
-TH1
Temperature
/15.2
12
previous
REV
DESCRIPTION
Updated Converter
14
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
13
25
TO Q1
UV TRIP COIL DTA
ELEMENTARY
=CFC/4.7
ROVC3-2
P17
COM
NO
P16
COM
NO
P13
COM
NO
P12
P11
COM
NO
P10
TO ROV
CONTACTOR
=CFC/4.5
ROVC3-1
-ROVCR
15 OHM, 40W
/22.8
/22.7
/22.8
/22.8
L1
L2
T3
L4
-2
T1
T2
L3
T4
-K4
A1
Supp
WIRE
JUMPER
SYNCRONIZATION
SWITCH PILOT
=PDC/7.3
-1
AEADP11
=PDC/7.3
AEADK1COM
A2
WIRE
JUMPER
RP24 / 15.1
13
previous
REV
DESCRIPTION
Updated Converter
J4-2
AEPSP4A1-2
19.8
AEPSP4A1-1
19.8
J4-1
I/O 1
IS200AEAD_H1A
-AEAD
RCOM / 15.1
15
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
14
25
NC
NO
COM
3.7
AEADK8NO
DTA Ventilator
FAN CONTACTOR
NC
COM
NC
COM
13
21
L1
L2
L3
NO
TO K5
PUMP MTR
4.1
4.1
=PDC/7.2
AEADK6COM
=PDC/7.2
AEADK6NO
/13.3
/5.4
=CFC/6.3
=CFC/6.4
=CFC/6.5
Sup
14
22
T1
T2
T3
A1
TO WEMA
Pump Motor
A2
P15
NC
-KDF
CFC
COM
NO
P14
DISTORTION
FILTER
CONTACTOR
TO Q1
CLOSING COIL
3.7
AEADK8COM
AEADK7COM
NO
AEADK7NO
14.8 / RP24
I/O 1
IS200AEAD_H1A
-AEAD
14.8 / RCOM
14
previous
REV
DESCRIPTION
Updated Converter
16
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
15
25
P8
P7
P3
P5
P1-1
P1-2
P1-3
I/O 1
IS200AEAD_H1A
-AEAD
Updated Converter
AEADP7
=PDC/6.6
AEADP5
=PDC/6.6
AEADP3
=PDC/6.5
AEADP1-3
8.5
GRID
MONITOR
VOLTAGE
FROM Q2
15
previous
REV
DESCRIPTION
AEADP1-2
8.5
-PEN
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
17
Main Control Cabinet
AEAD
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
16
25
P18-3
P18-1
P18-2
66
I1
I2
19.7 / AEPSP18A2-3
19.7 / AEPSP18A2-2
19.7 / AEPSP18A2-1
Chassis
=CFC/5.4 / AEAATB3-66
=CFC/5.3 / AEAATB3-65
=CFC/5.3 / AEAATB3-64
=CFC/5.3 / AEAATB3-63
=CFC/5.2 / AEAATB3-62
=CFC/5.2 / AEAATB3-61
Chassis
11.6 / MACCJ2
65
64
63
62
61
-TB3
J1
CCOM
CCOM3
E5
E4
CP24
CN24
CCOM
E4
1.5
1.5
I/O 2
IS200AEAA_H2B
-AEAA
E4
E4
1.5
I3
16
previous
REV
DESCRIPTION
Updated Converter
18
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
17
25
Updated Converter
=PDC/4.8 / AEAAP4-L3
P4
=PDC/4.8 / AEAAP3-L2
GENERATOR
STATOR
VOLTAGE
FEEDBACK
(690VAC)
=PDC/4.8 / AEAAP2-L2
P2
=PDC/4.8 / AEAAP1-L1
17
previous
REV
DESCRIPTION
P3
P1
I/O 2
IS200AEAA_H2B
-AEAA
19
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
18
25
previous
REV
DESCRIPTION
Updated Converter
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
E5
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
C
COPYRIGHT 2009 GENERAL ELECTRIC COMPANY
0.75F
COMPONENT
Downtower Assembly
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
P4A2-2
P4A2-1
AEPSP4A1-2 / 14.1
P4A1-2
AEPSP4A1-1 / 14.1
P4A1-1
AEPSP18A2-1 / 17.4
AEPSP18A2-2 / 17.4
AEPSP18A2-3 / 17.4
P18A2-1
P18A2-2
P18A2-3
AEPSP18A1-1 / 12.5
AEPSP18A1-2 / 12.5
AEPSP18A1-3 / 12.5
AEPSP2B2-1 / 21.1
AEPSP2B2-2 / 21.1
AEPSP2B2-3 / 21.1
AEPSP2B2-4 / 21.1
AEPSP2B2-5 / 21.1
AEPSP2B2-6 / 21.1
AEPSP2B1-1 / 20.1
AEPSP2B1-2 / 20.1
AEPSP2B1-3 / 20.1
AEPSP2B1-4 / 20.1
AEPSP2B1-5 / 20.1
AEPSP2B1-6 / 20.1
P18A1-1
P18A1-2
P18A1-3
P2B2-1
P2B2-2
P2B2-3
P2B2-4
P2B2-5
P2B2-6
P2B2-7
P2B2-8
P2B1-1
P2B1-2
P2B1-3
P2B1-4
P2B1-5
P2B1-6
P2B1-7
P2B1-8
AEPSP1-1 / 11.4
AEPSP1-2 / 11.4
AEPSP1-3 / 11.4
AEPSP1-4 / 11.4
AEPSP1-5 / 11.4
AEPSP1-6 / 11.4
AEPSP1-7 / 11.4
AEPSP1-8 / 11.5
E4
E3
DC Link N
E2
E1
P1-1
P1-2
P1-3
P1-4
P1-5
P1-6
P1-7
P1-8
GROUND PATH
TO CHASSIS
VIA MOUNTING
STANDOFF
-AEPSC1
22.5 / WEORJ4-4
22.4 / WEORJ4-1
DC Link P
-AEPS
0
8
9
18
(NOM. VOLTAGE 1073)
TYPE
1.6 xle
REV
= MCC
+
20
B
of
Sh
next
19
25
B
Updated Converter
19
previous
REV
DESCRIPTION
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
GENERAL ELECTRIC COMPANY
WIND ENERGY TECHNOLOGY
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
C
COPYRIGHT 2009 GENERAL ELECTRIC COMPANY
P10-1
P10-2
P10-3
PHASE C1
P1
PHASE C1
SEE PHASE A1
FOR DETAILS
P11
P9
P8
P4
P6
P2
P5
COMP NO.
COMPONENT
Downtower Assembly
P6
P4
P2
P5
P3
P1
-AEBM--C1
PHASE C1
SEE PHASE A1 FOR WIRING DETAILS
IS200AEBM-C1
(ON IGBT MODULE)
P3
P1
=CBC/3.9 / SHC1-CFCOM
=CBC/3.9 / SHC1-CSHB
PHASE B1
SEE PHASE A1
FOR DETAILS
P4-1
P4-2
P4-3
P4-4
P4-5
P4-6
-AEBM--B1
PHASE B1
SEE PHASE A1 FOR WIRING DETAILS
IS200AEBM-B1
(ON IGBT MODULE)
P6-4
P6-1
P6-2
P6-3
P5-4
P5-1
P5-2
P5-3
P2-6
P2-3
P2-4
P2-5
P2-6
P2-6
P3-7
P3-8
P3-9
P3-10
P1-1
P1-2
P1-3
P1-4
P1-5
P1-6
=CBC/3.9 / SHC1-CSHM
PHASE B1
P5-1
P5-2
P5-3
P5-4
P5-5
P5-6
P1-10
P1-1
P1-2
P1-3
P1-4
P1-5
P1-6
P1-7
P1-8
P1-9
=CBC/3.9 / SHB1-BFCOM
P7-1
P7-2
P7-3
P6
COLLECTOR
EMITTER
P15
GATE ON
GATE OFF
N7
P3-1
P3-2
P3-3
P3-4
P3-5
P3-6
P3-7
P3-8
P3-9
P3-10
=CBC/3.9 / SHB1-BSHB
=CBC/3.9 / SHB1-BSHM
IS200AEBI-1
PHASE A1
LOWER
LOWER
LOWER
LOWER
LOWER
LOWER
PHASE A1
UPPER COLLECTOR
UPPER EMITTER
UPPER P15
UPPER GATE ON
UPPER GATE OFF
UPPER N7
RTD1 BIAS
RTD1 INPUT
RTD2 BIAS
RTD2 INPUT
-AEBM--A1
PHASE A1
IS200AEBM-A1
(ON IGBT MODULE)
=CBC/3.9 / SHA1-AFCOM
P4-1
P4-2
P4-3
P2-1
P2-2
P2-3
P2-4
P2-5
P2-6
P2-7
P2-8
E2
DC LINKN
E1
DC LINKP
=CBC/3.9 / SHA1-ASHB
=CBC/3.9 / SHA1-ASHM
19.3 / AEPSP2B1-6
19.2 / AEPSP2B1-5
19.2 / AEPSP2B1-4
19.2 / AEPSP2B1-3
19.2 / AEPSP2B1-2
19.2 / AEPSP2B1-1
LINE CONVERTER
(BRIDGE 1) INTERFACE
-AEBI1
CS3N1
=CBC/4.8
CS3P1
=CBC/4.0
0
8
9
MACCP1 / 11.3
C:\EPLAN4\P\GEE\15ESS.P\P18MCC.bmp
TYPE
COMP-DRW. NO.
107W4611
1.6 xle
COMP-PART NO.
107W5379P001
REV
= MCC
+
21
B
of
Sh
next
20
25
20
previous
REV
DESCRIPTION
B
Updated Converter
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
GENERAL ELECTRIC COMPANY
WIND ENERGY TECHNOLOGY
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
C
COPYRIGHT 2009 GENERAL ELECTRIC COMPANY
COMPONENT
=CBC/5.9 / SHC2-CFCOM
=CBC/5.9 / SHC2-CSHB
P1
-E1
MACCP2 / 11.6
P11
Downtower Assembly
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
P5
P6
P4
P3
P5
P2
P1
P6
P4
P3
IS200AEBM-C2
(ON TOP IGBT MODULE)
P6
P4
P3
P2
P1
PHASE C2
SEE PHASE C2 FOR WIRING DETAILS
IS200AEBM-C2
(ON BOTTOM IGBT MODULE)
P5
P6
-AEBM--B2T
P10-3
P10-2
-AEBM--B2B
P10-1
P2
P4
P1
P5
P2
P3
IS200AEBM-B2
(ON TOP IGBT MODULE)
-AEBM--A2T
P1
PHASE B2
SEE PHASE A2
FOR WIRING DETAILS
IS200AEBM-B2
(ON BOTTOM IGBT MODULE)
P4
=CBC/5.9 / SHC2-CSHM
P9
P8
-AEBM--A2B
=CBC/5.8 / SHB2-BFCOM
P7-1
P7-2
P7-3
P6-1
P6-2
P6-3
P6-4
P5-1
P5-2
P5-3
P5-4
P2-6
P2-1
P2-2
P2-3
P2-4
P2-5
P1-10
P1-1
P1-2
P1-3
P1-4
P1-5
P1-6
P1-7
P1-8
P1-9
=CBC/5.8 / SHB2-BSHB
P4-1
P4-2
P4-3
P4-4
P4-5
P4-6
P3-9
P3-10
P3-8
P3-3
P3-4
P3-5
P3-6
P3-7
P3-1
P3-2
P6-1
P6-2
P6-3
P6-4
P5-1
P5-2
P5-3
P5-4
P2-6
P2-1
P2-2
P2-3
P2-4
P2-5
P1-9
P1-10
=CBC/5.8 / SHB2-BSHM
P6
P5-1
P5-2
P5-3
P5-4
P5-5
P5-6
P1-1
P1-2
P1-3
P1-4
P1-5
P1-6
P1-7
P1-8
P3
IS200AEBM-A2
(ON TOP IGBT MODULE)
=CBC/5.4 / SHA2-AFCOM
P4-1
P4-2
P4-3
P3-1
P3-2
P3-3
P3-4
P3-5
P3-6
P3-7
P3-8
P3-9
P3-10
PHASE A2
IS200AEBM-A2
(ON BOTTOM IGBT MODULE)
TO CS3
(NOM. VOLTAGE 1073)
=CBC/5.4 / SHA2-ASHB
=CBC/5.4 / SHA2-ASHM
19.4 / AEPSP2B2-6
19.4 / AEPSP2B2-5
19.4 / AEPSP2B2-4
CS3N
19.4 / AEPSP2B2-3
P2-1
P2-2
P2-3
P2-4
P2-5
P2-6
P2-7
P2-8
=CBC/4.8
CS3P
19.4 / AEPSP2B2-2
=CBC/4.0
19.4 / AEPSP2B2-1
-AEBI2
0
8
9
-AEBM--C2T
-AEBM--C2B
-E2
TYPE
1.6 xle
REV
= MCC
+
22
B
of
Sh
next
21
25
IS200WEOR_H1A
WEORJ4-1
WEORJ4-4
19.1
19.1
-J4-1-
-J4-4-
For AEPS
J4-2
J4-3
J5-1
J5-4
For Test
Discharge Ckt
-(WEOR)
FU4
-P6-1-
DC Bus P
P6-2
5A
220K
2W
0.5A
10 ohm
5w
P6-3
270uf
400v
P6-4
P6-5
.01uf
3kv
220K
2W
-P1-1-
AC
AC
-(WEOR)
FU1
P6-6
270uf
400v
-(WEOR)
FU5
-P1-4-
P6-7
-P6-8-
DC Bus N
WEOR-P6-1
-(WEOR)
FU2
=CBC/4.0
=CBC/4.8
5A
WEOR-P6-8
P1-3
-J2-22A
(SB)
J2-1
-J7-1-
H1
-T1
230:460
Isolation XFMR
200 VA
-WEORC1
9,000f
+30%/-10%
400V
-J7-2-
-J2-3-
H2
-K4
S
X1
X2
L1
MDL
0.5A
250v
J3-2
200 ohm
40w
K1
Coil
20K
10W
-K4
-K4
L2
-P8-2-
WEMA-J5B-N
/14.4
+
-
AC
-J3-1-
5.4
AC
WEMA-J5B-L
-P8-1-
6.6 ohms
6w
-(WEOR)
FU3
=PDC/7.7
DTAK1-A1
T1
T2
/14.4
T3
-K4
L3
L4
/14.4
=PDC/7.7
T4
DTAK1-A2
/14.4
-J3-3-
5.4
21
previous
REV
DESCRIPTION
Updated Converter
23
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
22
25
=CFC/3.3
PDCAUX-Q18-1
The voltage feeding FB5, FB6 and X5.1-1 determine the voltage applied
to the Lights and Sockets. The circuit can be fed from 120, 230 or 100
Volts; the default wiring shown on the elementary is for 120 Volts.
To change the voltage for the Lights and Sockets to 230 V rearrange
the connections to FB-5, FB-6 and X5.1-1 as follows:
=CFC/3.3
PDCAUX-Q19-1
=CFC/3.3
PDCAUX-Q20-1
Disconnect From
120 V L-N
Q9-2
Q10-2
Q11-2
Wire Feeding
FB5-1
FB6-1
X5.1-1
=CFC/3.5
PDCAUX-Q9-1
Connect To
230 V L-N
Q18-2
Q19-2
Q20-2
=CFC/3.5
PDCAUX-Q10-1
To change the voltage for the Lights and Sockets to 100 V, the
secondary taps of T2 (32.5 KVA) must be changed as follows
(see CFC sheet 1 )
=CFC/3.6
PDCAUX-Q11-1
Disconnect From
120 V L-N
T2-X4
T2-X5
T2-X6
Wire Feeding
Q9-1
Q10-1
Q11-1
=CFC/3.9
PDCAUX-Q12-L3
Connect To
100 V L-N
T2-X7
T2-X8
T2-X9
=CFC/3.9
PDCAUX-Q12-L2
=CFC/3.9
PDCAUX-Q12-L1
L1
=CFC/3.0
T2-X1
Optional
Connection
for 400Vac
=CFC/3.0
L2
L3
-Q12
-Q18
4-6.3A
(5A)
10A
-Q9
20A
-Q19
10A
-Q10
20A
T1
=CFC/3.0
T2
-Q11
10A
20A
-PDC_AUX
T2-X2
-Q20
-Outlet1
T3
T2-X3
1
25A
30mA
GFI
25A
30mA
GFI
Wire Feeding
Q12-L1
Q12-L2
Q12-L3
Disconnect From
208 V 3
T2-X4
T2-X5
T2-X6
Connect To
400 V 3
T2-X1
T2-X2
T2-X3
-PEN
-PEN
2
-X4.2
-FB6
-FB5
N
L
-PEN
N'
N'
Chassis
1(1)
2(1)
3(1)
4(1)
5(1)
1
-X4.2
-S3
1(2)
2(2)
3(2)
4(2)
Tower
Light
Switch
5(2)
-PEN
-PEN
-PEN
-PEN
-X5.1
1(1)
2(1)
3(1)
4(1)
5(1)
6(1)
7(1)
9(1)
11(1)
8(1)
10(1)
12(1)
13(1)
14(1)
15(1)
-X5.1
1(2)
2(2)
3(2)
4(2)
5(2)
6(2)
7(2)
9(2)
11(2)
8(2)
10(2)
12(2)
13(2)
14(2)
15(2)
Emergency
Lighting
(CE marked
towers only)
22
previous
REV
DESCRIPTION
Updated Converter
Tower
Lighting
Supply
Sockets
AC over
FI to Top Box
DTAGND3
=TB/11.1
DTAQL1-N
=TB/11.1
DTAQL1-2
=TB/11.1
DTAGND2
=TB/11.2
DTAFB6-N
=TB/11.2
DTAFB6-2
=TB/11.2
DTAGND1
=TB/11.4
DTAFB5-N
=TB/11.4
DTAS3-2
=TB/11.3
=TB/11.3
-TOWER HOIST
DTAFB5-2
Chassis
Obstruction
Lights
24
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
23
25
X3.1
1(1)
1(2)
2(1)
2(2)
=CFC/3.2 / Q8-2
3.4 / Q14-L1
3(1)
3(2)
4(1)
4(2)
5.0 / Q22-1
400 Vac
3 Phase
from Q8
=CFC/3.2 / Q8-4
5(1)
3.4 / Q14-L2
6(1)
10.4 / Q24-1
7(2)
8(1)
8(2)
3.4 / Q14-L3
9(1)
4.2 / WEMA-K15-NO
10(2)
11(1)
11(2)
=CBC/6.4 / HTR2-2
12(1)
13(1)
10.4 / MCC10
14(1)
15(1)
=CFC/5.6 / PUMP-M1-4
23
previous
REV
DESCRIPTION
Updated Converter
9(2)
10(1)
5.6 / UPSN-J1
-PENMCC
6(2)
7(1)
=CFC/3.2 / Q8-6
Optional
Energy
Meter
5(2)
12(2)
13(2)
14(2)
15(2)
WEMA-K14-NO / 4.2
WEMA-K1-NO / 4.4
WEMA-K2-NO / 4.5
WEMA-K3-NO / 4.5
Fan4-L / =CBC/6.1
WEMA-K13-NC / 4.8
-PENMCC
HTR1-2 / =CFC/5.6
Fan4-N / =CBC/6.1
K5-A2 / 3.7
WEMA-J9-4 / 5.1
HTR5-2 / =CFC/5.8
25
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
24
25
Fiber Optic
Patch Panel
Feed Thru
(SC/SC Style Connectors)
24
previous
REV
DESCRIPTION
Updated Converter
10
11
12
10
11
12
10
11
12
10
11
12
=CBC/1
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Downtower Assembly
COMP NO.
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= MCC
+
Sh
of
25
25
BioEnergy
Component:
Comp No.:
Comp-Drw. No.:
Comp-Part No.:
107W4611
107W5379P001
MAIN
TRANSFORMER
GEN
STATOR
GEN
ROTOR
690 V
690 V
690 V
50/60 Hz
50/60 Hz
50/60 Hz
1430
1400
640 MAX
Uodated Converter
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
R. Shaw
J. Curtis
GE Energy
DRAWN
ISSUED
26-MAR-2009 G. Stultz
DWB
2
DATE
SIGNATURE
ENGINEER
26-MAR-2009 A. Klodowski
DRAWN
26-MAR-2009 G. Stultz
CHECKED
26-MAR-2009 A. Klodowski
ISSUED
DWB
next
GE Energy
COMPONENT
TYPE
1.6 xle
= CBC
+
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
Sh
of
1
6
date
New Release
07/23/09
3, 5, 24
11/03/09
4, 5
Updated Converter
page
change
revision
03/26/09
1
previous
REV
DESCRIPTION
actual state
3
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= CBC
+
Sh
of
2
6
S2
SHC1CSHM
CONV-L1-C1
SHIELD
S1
S2
-SHB1
BUS
=MCC/20.7
=CFC/6.7
400A
50mV
CONV-L1-B1
=MCC/20.5
SHC1CFCOM
BUS
400A
50mV
=MCC/20.7
S1
-SHC1
B1-EU/CL
SEE PHASE A1
FOR DETAILS
BUS
-PHASE B1
=MCC/20.5
C1-EU/CL
SEE PHASE A1
FOR DETAILS
BUS
-PHASE C1
POS DC LINK BUS
=MCC/20.7
=MCC/20.5
SHC1CSHB
SHB1BSHB
SHB1BSHM
SHB1BFCOM
4.8
DCN13
DCP13
4.1
=CFC/6.6
400A
50mV
S2
CONV-L1-A1
=MCC/20.3
=MCC/20.3
-SHA1
=MCC/20.3
S1
SHA1ASHM
SHA1AFCOM
A1-EU/CL
SHA1ASHB
SHIELD
=CFC/6.6
2
previous
REV
DESCRIPTION
Updated Converter
HTSK CHASSIS
BUS
-PHASE A1
BUS
SHIELD
4
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= CBC
+
Sh
of
3
6
5.1
DCN14
-CS4
5.1
DCP14
=MCC/21.0
=MCC/21.0
CS3P
CS3N
=MCC/20.0
=MCC/20.0
CS3N1
-CS3
CS3P1
=MCC/22.8
=MCC/22.8
Updated Converter
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
DCN13
3.8
3
previous
REV
DESCRIPTION
DCP13
3.0
-CS1
NEG DC LINK
-CS2
WEOR-P6-8
POS DC LINK
WEOR-P6-1
COMPONENT
5
TYPE
1.6 xle
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= CBC
+
Sh
of
4
6
-PHASE A2
-PHASE B2
-PHASE C2
SEE PHASE A2
FOR DETAILS
A2-EU/CL
SEE PHASE A2
FOR DETAILS
B2-EU/CL
C2-EU/CL
HTSK CHASSIS
4.8 / DCN14
S2
SHIELD
CONV-L2-C1
=CFC/4.2
SHIELD
Updated Converter
=MCC/21.8
=CFC/4.1
=MCC/21.8
CONV-L2-B1
800A
50mV
SHC2CSHM
S2
previous
REV
DESCRIPTION
6
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= CBC
+
1.6 xle
=MCC/21.8
SHC2CSHB
=MCC/21.5
S1
SHC2CFCOM
SHIELD
=MCC/21.5
=CFC/4.0
-SHC2
=MCC/21.6
CONV-L2-A1
S1
SHB2BSHM
S2
=MCC/21.3
=MCC/21.3
800A
50mV
SHA2ASHM
-SHB2
800A
50mV
SHA2AFCOM
-SHA2
SHB2BSHB
SHB2BFCOM
S1
=MCC/21.3
SHA2ASHB
Sh
of
5
6
L2, 230Vac
WEMAK2-COM / =MCC/4.5
Fan4-N
=MCC/24.6
Neutral
Fan4-L
=MCC/24.6
L2, 230Vac
WEMAK1-COM / =MCC/4.4
L2, 230Vac
WEMAK3-COM / =MCC/4.5
1
-OT2
Trip Open when Temp>202F (94C)
Push button to reset when Temp<130F(54C)
Manual Reset Thermostat
-OT3
-OT4
-HTR2
1000W
-HTR3
1000W
-HTR4
1000W
N
=MCC/24.3 / HTR2-2
NOTE:
Heaters are on when MCC Temp <10C.
Heaters are Duty Cycle Modulated to
keep MCC Temp> Air Inlet Temp.
-Fan4
220/230 Vac
Single Phase
50 Hz, 0.22A, 52W
60 Hz 0.25A, 59W
-Fan3
220/230 Vac
Single Phase
50 Hz, 0.22A, 52W
60 Hz 0.25A, 59W
-Fan2
220/230 Vac
Single Phase
50 Hz, 0.22A, 52W
60 Hz 0.25A, 59W
5
previous
REV
DESCRIPTION
Updated Converter
=TB/1
CHECKED BY
REVISED BY
03-NOV-2009 03-NOV-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
26-MAR-2009 G. Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
COMP-DRW. NO.
107W4611
COMP-PART NO.
107W5379P001
REV
next
= CBC
+
Sh
of
6
6
Cover Page
GE Wind Energy 1.6MW
WTG Drw No.:
WTG No.:
Project/CMS No.:
Customer:
Component:
Comp No.:
Comp-Drw. No.:
Comp-Part No.:
Frequency:
Rated Voltage:
Control Voltage:
108W6614
16111805 - 813
Aratua-1 / 712835
BioEnergy
Top Box
107W6155
107W5345P001
50 / 60Hz
690V, PEN / 3 PH, 80A, 400/230V, N, PE / 3PH, 20A, 230V, N, PE / 16A
230V / 24VDC
DATE
=CBC/6
previous
REV
DESCRIPTION
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
B.FERGUSON
M. MENNIS
GE Energy
DRAWN
ISSUED
25-APR-2008 G.Stultz
DWB
SIGNATURE
ENGINEER
18-DEC-2007 A. Ridenour
DRAWN
25-APR-2008 G.Stultz
CHECKED
25-APR-2008
ISSUED
DWB
next
GE Energy
Top Box
Documentation
A. Ridenour
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
= TB
+
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
Sh
of
1
31
DATE
REVISION
CHANGE
Initial Release
ALL
12/03/09
28, 30
1-NOV-2010
1, 8 19
ECO / ECR
PAGE
5/27/09
1
previous
REV
DESCRIPTION
ECR3036610
3
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
2
31
=MCC/10.7
690VAC
from
PDC
-F1
DTA690T1
-X2.1
-X2.1
=MCC/10.8
1(2)
1(1)
DTA690T2
2(2)
=MCC/10.8
L1A
4.0
690VAC
L2A
2(1)
4.0
DTA690T3
3(2)
=MCC/10.9
4.0
L3A
3(1)
DTA690PEN
4(2)
32A
aM
-F6
32A
aM
-F7
L1
/18.5
/18.5
/18.5
L2
L3
PE
TVSS
PE Bus
L1
L2
L3
-Q1
/16.3
19-25A
Yaw Shutdown
(25A)
T2
T3
690VAC
-F2
L1
20A
gG
L2
L3
-K1
-X2.2
/16.2
Yaw Motors
2(1)
Reversing
Contactor
L1B
L2B
L3B
L1
L2
L3
T1
T2
T3
-K2
T1
T2
/16.3
Yaw Motors
T3
Vendor
Seimec
Name Plate
Current
5.0A@690V
Motor
Starter
Setting
5.0A
(%)
690V PE
=SR/4.1
690V L3
=SR/4.1
690V L2
=SR/4.0
690V L1
=SR/4.0
(%)
Note:
If Motor is not
listed set Starter
@ 110%
690V to Control
Cabinet via
Slipring
Busbar
Busbar
Busbar
L1
-X2.4
1(1)
-X2.1
4(1)
L2
L3
L1
L2
L3
L1
-Q3
-Q4
-Q5
/18.4
4-6.3A
Yaw2
*
/18.4
4-6.3A
Yaw3
*
/18.4
4-6.3A
Yaw4
*
-M1
L1
-Q2
Yaw 1
2
previous
REV
DESCRIPTION
L3
/18.4
4-6.3A
Yaw1
*
T1
PE Bus
L2
T2
M
3~
T3
-X2.4
1(2)
-M2
Yaw 2
T2
T3
M
3~
-X2.4
2(2)
-M3
Yaw 3
T2
M
3~
L3
T3
-X2.4
L2
T1
3(2)
-M4
Yaw 4
T2
M
3~
T3
-X2.4
4(2)
PE Bus
4
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
3
31
3.9
L1A
5.0
690VAC
Busbar
L1A
3.9
5.0
L2A
Busbar
L2A
Busbar
L3A
3.9
5.0
L3
L1
L3
L1
-Q6
-Q7
-Q8
1-1.6A
*
6.3-10A
(10)
9-13A
(13)
Svend Hoyer
Name Plate
Current
1.05A@690V
Motor
Starter
Setting
1.15A
(%)
(%)
T3
-X2.2
2(2)
Generator Fan
External
Cooling Circuit 1
Note:
If Motor is not
listed set Starter
@ 110%
T2
=GE/6.1
K4-PE
K4-T3
=GE/7.0
K4-T2
=GE/7.0
=GE/7.1
-X2.2
T1
3(2)
=GE/6.1
/21.8
Gen Fan
Internal
Cooling
T3
K5-T3
T2
1(2)
Hydraulic Pump
Vendor
T1
K4-T1
K3-PE
K3-T3
=GT/13.8
K3-T2
=GT/13.8
K3-T1
=GT/13.7
-X2.2
-K5
/21.7
Gen Fan
External
Cooling
T3
=GT/13.8
T2
L3
K5-PE
-K4
T1
=GE/7.1
-K3
/21.7
Hydraulic Pump
L2
K5-T1
-X2.2
L2
=GE/6.0
L2
K5-T2
L1
=GE/6.0
L3A
Generator Fan
Internal
Cooling Circuit
1(1)
PE Bus
3
previous
REV
DESCRIPTION
5
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
4
31
4.9
L1A
6.0
690VAC
Busbar
L1A
4.9
6.0
L2A
Busbar
L2A
Busbar
L3A
4.9
6.0
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
-Q10A
-Q10B
-Q10C
-Q9
1.6-2.5A
1.6-2.5A
1.6-2.5A
/18.4
1.6-2.5A
-K7A
-K7B
/21.0
T1
T2
T1
T2
-K6
/21.2
T3
L3
-K7C
/21.1
T3
L2
T1
T2
/21.9
T3
T1
T2
T3
-X2.3
Voltage(V)
Power(W)
Current(A)
690, 3ph
785
0.66
Motor
Starter
Setting
1.6
Vendor
Flender
Gearbox
Heating
Element 3
Voltage(V)
Power(W)
Current(A)
690, 3ph
785
0.66
Motor
Starter
Setting
1.6
Vendor
Flender
K6-PE
=GE/8.1
K6-T3
=GE/8.1
K6-T1
=GT/14.4
6(2)
K7C-PE
=GT/14.4
K7C-T3
=GT/14.4
K7C-T2
=GT/14.4
K7C-T1
=GT/14.3
Gearbox
Heating
Element 2
(%)
4
previous
REV
DESCRIPTION
-X2.2
5(2)
K7B-PE
K7B-T3
=GT/14.2
K7B-T2
=GT/14.2
K7B-T1
=GT/14.1
Gearbox
Heating
Element 1
=GT/14.2
-X2.2
4(2)
K7A-PE
=GT/14.1
K7A-T3
=GT/14.1
K7A-T2
=GT/14.0
K7A-T1
-X2.2
4(2)
=GE/8.2
L3A
Generator
Standby Heater
Voltage(V)
Power(W)
Current(A)
690, 3ph
785
0.66
(%)
Motor
Starter
Setting
1.6
Vendor
Winergy
Voltage(V)
Power(W)
Current(A)
690, 1ph
500
0.72
(%)
Motor
Starter
Setting
1.6
(%)
Note:
If Motor is not
listed set Starter
@ 110%
(%)
6
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
5
31
690VAC
5.9
L1A
Busbar
L1A
5.9
L2A
L2A
Busbar
5.9
L3A
L3A
Busbar
L1
L2
L3
L1
T2
T3
L1
L2
L3
L1
L2
L3
L1
-Q15
-Q16
-Q17
-Q18
9-13A
2.5-4A
4-6.3A
-K14
/21.4
L3
6.3-10A
T1
L2
-K10
-K12
/21.2
T1
T2
/21.4
T3
T2
-K13
/21.3
T3
L3
-K11
T1
L2
T1
T2
/21.5
T3
T1
T2
T3
Gearbox
Lubricating
Pump
High
Speed
-X2.3
Gearbox
Lubricating Pump
low speed
1(1)
Vendor
Flender
Voltage(V)
Power(KW)
Current(A)
690, 60hz
4.2
6.9
RPM
860
Motor
Starter
Setting
7.6
Vendor
Flender
Voltage(V)
Power(KW)
Current(A)
690, 60hz
7.2
8.0
(%)
-X2.3
RPM
1730
Motor
Starter
Setting
9.0
Vendor
Flender
Voltage(V)
Power(KW)
Current(A)
690, 60hz
1.8
3.2
(%)
RPM
1160
=GT/13.3
3(2)
K13-PE
=GT/13.3
K13-T3
=GT/13.2
K13-T2
=GT/13.2
=GT/13.1
K13-T1
2(2)
K11-PE
K11-T3
=GT/13.1
K11-T2
=GT/13.1
K11-T1
=GT/13.6
Gearbox
Lubricating Pump
high speed
=GT/13.1
-X2.3
1(2)
K12-PE
=GT/13.6
K12-T3
=GT/13.6
K12-T2
=GT/13.6
K10-T3
=GT/13.4
K10-T2
-X2.3
5(2)
K12-T1
8(2)
7(2)
=GT/13.5
6(2)
K10-PE
-X2.4
=GT/13.4
8(1)
=GT/13.4
6(1) 7(1)
K10-T1
-X2.4
Vendor
Voltage(V)
Flender
690, 60hz
Power(KW)
3.6
Current(A)
4.8
RPM
Motor
Starter
Setting
1740
5.3
(%)
(%)
(%)
Note:
If Motor is not
listed set Starter
@ 110%
PE Bus
5
previous
REV
DESCRIPTION
7
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
6
31
=CFC/3.0
DTA400T1
=CFC/3.0
-X3.3
-X3.3
-X3.1
-X3.1
-X3.1
35(2)
35(1)
11(1)
12(1)
9(2)
8.0
-X3.1
400VAC
400L1
11(2)
8.0
DTA400T2
400L2
36(2)
=CFC/3.1
36(1)
16(1)
17(1)
14(2)
8.0
DTA400T3
400L3
37(2)
=CFC/3.1
37(1)
20(1)
21(1)
18(2)
=CFC/3.1
DTA400PE
38(2)
38(1)
39(2)
39(1)
7(1)
8(1)
8.0
-X3.1
DTA400N
1(2)
400N
3(2)
2(2)
PE
400VAC To PDC
DTA_Elementary
-Q19A
13A
-PE Bus
13A
-F5
/18.5
TVSS
-Q19B
1
L1
L2
-Q19C
13A
1
2
1
2
1
L3
GND
-Q28
-X3.2
1(1)
-X3.2
2(1)
-X3.2
1(2)
-X3.2
2(2)
3A
PE Bus
PE Bus
-Q20
1A
Control Cabinet
Heaters via
Slip Ring
-WETB
J6
P24SW
-X3.2
-X3.2
3(1)
250V
0.315A
-K7
UPS/Heater
Control Power
Supply
Yel
3(2)
P24UR
-FU6
K7
30HPE.4.1
=SR/5.7
SRH.PE
=SR/5.6
SRH.N
=SR/5.6
-PE Bus
30SRH.L1
=SR/4.3
30HN.4.1
=SR/4.3
30HL3.4.1
=SR/4.2
30HL2.4.1
=SR/4.2
30HL1.4.1
=SR/4.2
J20
230V
to Slip Ring
Heater (50 W)
6
previous
REV
DESCRIPTION
8
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
7
31
7.9
9.0
400L1
400L1
7.9
400L2
-X3.1
X3.1
7.9
15(2)
13(2)
400L3
9.0
400L2
9.0
400L3
7.9
9.0
400N
400N
5(2)
7(2)
-Q22
3A
Yaw
Lubrication
Pump
-WETB
-Q26
J1
/18.4
3A
Yaw Brake Motors
13K4A
Cable
Twist
Switch
P24SW
Yaw Lube Pump
13K4B
Voltage Sense
P24SW
-K18
Digital Output
Yaw Brakes
-K17
Yel
K18
Yel
K17
P39
L1
L2
J4A
J4B
L1
J4C
J4D
L1
-2
PE
1A1
L1
N
empty
message
-PE
bl
L1
rt
L1
-1M1
YAW Brake 1
50W
-PE
YAW Brake 2
50W
-PE
YAW Brake 3
50W
-PE
YAW Brake 4
50W
-PE
U: 230V
P: 46W
I: 0.2A
7
previous
REV
DESCRIPTION
9
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
8
31
8.9
10.0
400L1
400L1
8.9
400L2
X3.1
8.9
16(2)
400L3
10.0
400L2
10.0
400L3
8.9
10.0
400N
400N
6(2)
-Q24
3A
Heaters
-WETB
J1
P24SW
P24SW
Lube Pump
Heater
P24SW
-K3
-K2
Yaw Heaters
P24SW
Hydraulic
Pump
Heater
Oil Cooler
Heater
-K4
-K1
Yel
Yel
Yel
K2
Yel
K3
K4
K1
J8
L1
N
Lube Pump
Heater
100W
8
previous
REV
DESCRIPTION
Oil Cooler
Heater
25W
PE
J8-PE3
PE
=GT/14.9
PE
=GT/14.9
2E4
Heating Element
Yaw Motor 4
50W
WETB-J8-12
2E3
Heating Element
Yaw Motor 3
50W
12
=GT/14.8
L1
L1
WETB-J8-5
2E2
Heating Element
Yaw Motor 2
50W
J8-PE1
L1
=GT/14.6
2E1
Heating Element
Yaw Motor 1
50W
L1
11
=GT/14.5
L1
=GT/14.7
WETB-J8-1
L1
10
WETB-J8-11
J4D
=GT/14.5
WETB-J8-3
J4C
J8-PE2
=GT/14.7
J4B
=GT/14.7
WETB-J8-10
J4A
Hydraulic
Pump
Heater
10
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
9
31
9.9
-X3.1
400L1
10(2)
9.9
400L2
9.9
400L3
X3.1
9.9
19(2)
400N
-Q23
2(1)
J21
4(2)
-Q27A
3A
Heating Pipe
Exchanger Pump
6A
27.0
400N
-Q25
3A
Cabinet Fans
-WETB
21(2)
20(2)
400L2
17(2)
X3.1
1(1)
27.0
-X3.1
J6
-Q27B
6A
J1
3(1)
-Q27C
6A
J21
P24SW
P24SW
P24SW
-K11A
-K10A
P24SW
-K12A
P24SW
Yel
Yel
K5
-K14
K11A
Yel
Voltage
Sense
K10A
Voltage
Sense
K12A
Voltage
Sense
P24SW
Yel
Yel
K14
Heat Wrap
P24SW
K5
P24SW
-K11B
-K10B
-K12B
Yel
Yel
K11B
Yel
K12B
K10B
J3
P6
J2A
-E7A
L1
-M1
Fan
L1
M
1~
-M2
Fan
J2C
-E7C
-E9A
-E7B
M
1~
PE
J2B
-E9B
L1
PE
-PE
Heating
Element
Heat Wraps
Top Box
Heater 1
500 W
Each
Top Box
Heater 2
500 W
Each
Top Box
Heater 2
350 W
Each
(Optional)
9
previous
REV
DESCRIPTION
11
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
10
31
X5.1
X5.1
4(1)
5(1)
6(1)
7(1)
L1
X5.1
5(2)
7(2)
X5.1
X5.1
8(1)
9(1)
PE
L1
PE
X2
Socket Top Box
30OutN
X1
Socket Top Box
=SR/4.4
=SR/4.4
30OutL1
X5.1-19(1)
X5.1
-PE Bus
16(1)
10(1)
11(1)
L'
17(1)
FAA Or
Emergency Lighting
PE
FAA Lights
(If no Emergency Lighting)
Obstruction Lights
(If Tower cables attached)
15(2)
18(2)
PE
Nacelle Lighting 1
Outlets
19(2)
12(1)
X5.1
15(1)
Nacelle Lighting 2
=SR/4.5
30BelL1
=MCC/23.5
18(1)
PE
DTAGND1
=MCC/23.5
DTAFB5-N
=MCC/23.4
=MCC/23.4
16(2)
X5.1
DTAS3-2
8(2)
DTAFB5-2
=MCC/23.8
6(2)
DTAGND2
=MCC/23.7
=MCC/23.7
DTAFB6-N
4(2)
X5.1
DTAFB6-2
=MCC/23.9
3(2)
DTAGND3
DTAQL1-N
DTAQL1-2
=MCC/23.8
=MCC/6.4
2(2)
10
previous
REV
DESCRIPTION
=MCC/23.9
1(2)
X5.1
13(2)
X5.1
=SR/4.5
12(2)
X5.1
30OUTBPE
3(1)
30BelN
2(1)
Not Switched
X5.1-1(1)
=SR/4.4
RJ45
Lights
12
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
11
31
-K21
P24R
WETB
Yel
J17
29.8
WETB-J17-1
230VAC
from UPS
29.8
WETB-J17-3
J18
-K21
-FU1
250V
10A
-T2
L
600W
24A
24 VDC
Power Supply
PE
AC 230
+ 24 VDC
++
GND
-X6.2--3(2)
-Q33
-K27
-K28
-Q30
10A
-Q31
2
10A
-X6.2--1(1)
2
-X6.2--1(2)
-X6.2--2(2)
-X6.2--2(1)
OPTION
P24SW
-K29
CBM-V1-
P24SW
-PE Bus
CBM-V1+
3A
/15.6
P24SW
31.1
250V
5A
-12K2A
P24SW
GND
-FU4
T2
Power Supply
Monitor
PE
-X6.2--3(1)
T2 OK
GRN
+ 24 VDC
-PE Bus
J9
L
AC 230
-K30
J15
31.1
300W
12A
24VDC
Power
Supply
-PE Bus
-T3
PE Bus
OPTION
PP24
Yel
Yel
K27
Yel
K28E
Yel
K29
PS24
K30
P24
P24
GRN
-FU7
Valve
21
Valve
23
-FU8
=GT/12.3
=GT/12.2
=GT/12.8
Valve
20
250V
3.15A
WETB-P7-8
WETB-P7-4
WETB-P7-7
=GT/12.7
3
WETB-P7-3
=GT/12.8
=GT/12.9
WETB-P7-6
WETB-P7-2
WETB-P7-5
=GT/12.3
WETB-P7-1
=GT/12.4
P7
PSCOM
P24UR
P24UR
GRN
250V
3.15A
Valve
22
previous
REV
DESCRIPTION
13
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
12
31
V1+
P8
WETB
WETA
To Downtower
Assembly
Port 2
CBM-ETH / 31.2
OPTION
Port 8
30 FTH / =SR/5.4
To Pitch System
VIA SLIP RING
BPPB
J4
Port 1
V1-
Fiber In / =MCC/6.4
GRN
NTRON
PCOM
PS24
P24
GRN
-FU2
J11
J10
-FU2
250V
3.15A
250V
3.15A
-13K3
/15.3
P24SW
P24SWOK
GRN
PCOM
P24 OK
PCOM
-FU9
250V
3.15A
PS24
P24
J12
J13
-(WETC)FU2
250V
3.15A
PCOM
P24SW
-(WETC)FU3
PCOM
250V
3.15A
J22
1
2
3
4
WETC
PCOM
12
previous
REV
DESCRIPTION
14
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
13
31
WETB
Serial Data UART
Board ID
Bus
RS-485
COMM
Port
RS-485
COMM
Port
P44B
10
11
12
13
14
15
16
17
18
19
P44A
12
11
P44C
ICOM_3
RS-485
COMM
Port
RS-485
COMM
Port
WETA
FGPA
13
previous
REV
DESCRIPTION
ICOM_3
WETC
ICOM_3
RS-485
COMM
Port
Cable
ID
20
RS-485
COMM
Port
Board ID
Bus
15
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
14
31
2A
2B
22
14
14
-12S1
-S6
E-Stop
Top Box
P12
1A
1B
21
13
P13
Digital Input
24VDC
13
21
P14
Digital Input
24VDC
YEL
YEL
S6ESTP
-12K3
Digital Input
24VDC
ESTOP Hub
/17.4
YEL
VIBESW
P15
External
3
Yaw On/Off
ROTBLK
External
Stop/Reset
-18S2.2
-18S2.1
Stop/Reset
Top Box
-S7
Rotor
Blocking
Device
22
-12S4
Vibration
Switch
P16
Digital Input
24VDC
Digital Input
24VDC
Digital Input
24VDC
YEL
YEL
YEL
S7PB
EXTS7
EXTYAW
-12K3
/17.4
13K1
-13K3
GRN
/13.2
13K3
13K1
GRN
-12K2A
YEL
GRN
/12.4
/17.1
12K2
-12K2B
P24
WDOGA
-13K1
GRN
-(WETB)
K13
-(WETB)
K11
YEL
/17.1
/17.3
Digital Input
24VDC
RED
WDOGB
ESTMCC
WETB
WETC
P41B
P11B
P41C
P11A
P24
P24B
Rotor Overspeed
Hardware
Shutdown
Rotor Speed >Shutdown Speed
29.8
WETBP10-3A
29.8
WETBP10-2A
29.7
WETBP10-1A
YEL
ROT_OS
29.8
WETA-P24B-1A / 29.5
WETBP10-4A
29.8
14
previous
REV
DESCRIPTION
ESTOP
WETA-P24B-3A / 29.5
29.8
Communication
Watchdog
WETA-P24B-2A / 29.5
WETBP10-6A
YEL
Rotor Speed
To Turbine
Rotor Speed
Sensor 2
WETBP10-5A
-(WETC)K1
WETA
WETA
Communication
Watchdog
P24
P10
16
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
15
31
11S5
Cable
Twist
Switch
Ladder Limit
Switch 1
Ladder Limit
Switch 2
(Optional)
(Optional)
26
25
29.2
29.2
S5-1
S5-2
29.2
29.2
WETB-P5-1
WETB-P5-2
P5
-P24
-K22
P3A
Cable twist
switch bypass
Cable
Twist
Switch
Detection
P3B
Digital Input
Digital Input
YEL
YEL
LLSW1
LLSW2
-P24SW
-13K4
GRN
-P24
13K4
-P24
YEL
PCOM
YEL
YEL
-FU5
RD
RD
YEL
YEL
YAWRT
YAWLT
Yaw Shutdown
DO
250V
3.15A
CBS1
Digital
Input
CBS2
Digital
Input
CBS3
Digital
Input
WETB
P4
PCOM
P50
16.1
02
02
-K2
.3
-K1
01
A1
-K2
15
previous
REV
DESCRIPTION
01
T1
T2
T3
C1
A2
.3
/3.4
/3.4
/3.4
34
-Q1
A2
02
L1
L2
L3
.3
01
A1
-K1
33
-Q1
02
L1
L2
L3
C2
01
T1
T2
T3
.2
/3.5
/3.5
/3.6
33
34 .3
17
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
16
31
WETB
-PP24
-FU3
250V
3.15A
-12K2A
/15.6
-12K2B
/15.6
P24SW
P24SW
P24SW
-K25
-K24
P24SW
-K26
-K19
PCOM
17.7
YEL
YEL
K24
YEL
K25
P24SW
-K20
-PP24
-12K3
RED
/15.1
/15.4
YEL
K26
YEL
K19
PCOM
K20
P9
J16
29.4
30L-24.1A
29.4
30L+24.1A
=SR/4.8
Mains
Operation
Pitch
B
30MCA3.1
=SR/4.8
30MCA2.1
Safety Chain
From Hub
Safety
Loop
To
Hub
Mains
Operation
Pitch
A
=SR/4.9
30SKO.1
=SR/4.7
30SKI.1
=SR/4.7
16
previous
REV
DESCRIPTION
30MCA1.1
=SR/4.8
30BBR3.1
Brake
Battery
Run
17.3
nc
EstHub
Mains
Operation
Pitch
C
18
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
17
31
(Optional)
-Q9
-Q26
/5.7
/8.3
13
24
14
30.1 WETC-P38-15
23
30.1 WETC-P38-15A
14
/3.4
12A
11B
-Q4
MPSW2A
/3.6
-S2
4
-S5
2
-Q3
13
14
-Q2
/3.3
-F5
/7.1
14
12
30.1
13
12C
11
OVP Active
13
12
11
/3.4
WETC-P38-16A
10
11C
-F7
30.8
12B
F5-12
Start
Yaw On / Off
4
/3.4
14
/3.5
P38
30.1
13
-S4
-S3
-F7
Motor Protection
-S1
30.1
-F7
GE-X6-4A
MPSW1A
14
Generator
Brush Wear
11A
13
30.1
Light
Failure
30.1
/3.8
Light
Malfunction
GE-X6-1A
-Q5
Light
Intensity
Switch
15
16
P40
P18
GRN
3
Generator Brush Wear
Contact Interface
Digital
Input
Digital
Input
YEL
Digital
Input
YEL
Digital
Input
YEL
Digital
Input
YEL
Digital
Input
YEL
Digital
Input
YEL
Digital
Input
YEL
Digital
Input
YEL
P24GB
Digital
Input
YEL
YEL
Isolated
Power
MPAC
S3SW
S4SW
OVPA
LINTSW
OBSTR1
OBSTR2
S5SW
Dry
Contact
Input
S2SW
S1SW
Power
Source
Digital
Input
Control to Interface
Galvanic Isolation
1500 VAC
GENBW
WETC
17
previous
REV
DESCRIPTION
YEL
19
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
18
31
GBX
Kidney
Filter
Clogging
30.3
WETC-P28-12
30.3
WETC-P28-12A
30.3
WETC-P28-11A
11
(Optional)
30.3
30.3
WETC-P28-10A
10
WETC-P28-11
30.3
WETC-P28-10
30.2
WETC-P28-9A
30.2
WETC-P28-9
GBX
Pressure
Switch
Kidney
Filter
Low
Brake released
30.2 WETC-P28-8A
30.2 WETC-P28-7A
30.2 WETC-P28-6A
P28
hydraulic system
pressure min
;1
30.2 WETC-P28-5A
;11
9;10
30.2 WETC-P28-4A
30.2 WETC-P28-3A
30.2 WETC-P28-2A
30.1 WETC-P28-1A
30.4 WETC-P26-11A
30.4 WETC-P26-10A
30.4 WETC-P26-9A
30.4 WETC-P26-8A
Gearbox Filter
Contamination Coarse
30.4 WETC-P26-7A
30.4 WETC-P26-6A
Gearbox Filter
Contamination Fine
30.3 WETC-P26-5A
30.3 WETC-P26-4A
30.3 WETC-P26-3A
30.3 WETC-P26-2A
30.3 WETC-P26-1A
P26
12
12
-FU4
Digital Input
Digital Input
Digital Input
YEL
YEL
GBXOT
GBXOIL
Digital Input
YEL
GBXFF
YEL
250V
0.315A
Digital Input
YEL
-P24
GBXFC
Digital Input
Digital Input
YEL
PCOM
GBX08
WARN
Digital Input
Digital Input
YEL
YEL
YEL
ERROR
HPMIN
BRACT
Digital Input
YEL
GBXFL
Digital Input
YEL
BBXFC
WETC
18
previous
REV
DESCRIPTION
20
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
19
31
YAW 3
TEMPERATURE
SUPERVISOR
YAW 4
TEMPERATURE
SUPERVISOR
wht
wht
30.1
30.1
P17D-2A
30.0
P17D-1A
YAWTH3
brn
P17D-2
30.0
YEL
YAWTH2
P17D-1
30.0
P17C-2A
2 P17D
Digital Input
YEL
YAWTH1
30.0
brn
P17C-2
30.0
P17C
Digital Input
YEL
SP3
P17C-1A
30.0
30.0
P17B-2A
P17C-1
30.0
Digital Input
brn
P17B-2
30.0
P17B-1A
2 P17B
YEL
SP2
30.0
P17B-1
30.0
P17A-2A
Digital Input
YEL
wht
brn
30.0
-P24
P17A
wht
P17A-2
SP1
30.0
Digital Input
YEL
P17A-1A
Digital Input
Config
Customer
Digital Input/
Spare 3
30.0
TB2
Config
Customer
Digital Input/
Spare 2
P17A-1
Config
Customer
Digital Input/
Spare 1
YAW 1
TEMPERATURE
SUPERVISOR
OIL
EXCHANGER
THERMOSTAT
(Optional)
P42
Digital Input
YEL
YAWTH4
Digital Input
YEL
690V Ambient
Temperature
-TH1
P43
Spare
Thermistor
Input
Thermistor
Analog Input
24 VDC
10 K ohms= 25 degrees C
Thermistor
Analog Input
24 VDC
10 K ohms= 25 degrees C
OEXTH
-(WETC)
FU1
250 VDC
0.315A
WETC
19
previous
REV
DESCRIPTION
21
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
20
31
WETC
-P24SW
-P24SW
RD
RD
YEL
16
17
21
A2
A2
22
22
.2
Supp
Supp
A1
.3
.6
.2
/6.0
14
A1
-K12
A2
20
P2
K4
YEL
K5
K6
PCOM
A2
.2
/6.4
/6.4
/6.4
21
22
T1
T2
T3
.3
/6.8
/6.8
/6.8
21
T1
T2
T3
22
L1
L2
L3
.2
/6.0
/6.0
/6.1
A2
T1 /4.1
T2 /4.1
T3 /4.2
A1
-K6
A2
A2
Generator
Standby Heater
22
T1
T2
T3
A2
A1
-K5
Generator Fan
Internal Ckt
21
A2
A1
-K4
Generator Fan
External Ckt
.5
/6.6
/6.6
/6.6
A1
-K3
Hydraulic Pump
22
T1
T2
T3
A1
Gearbox Lube
Pump High Speed
21
32
-K14
Gearbox Oil
Cooler High
Speed
.4
.6
/6.2
/6.2
/6.2
.2
22
A1
Gearbox
Lubricating Pump
High Speed
22
32
T1
T2
T3
31
-K10
-K13
A2
Gearbox
Oil Cooler
Low Speed
21
31
10
21
-K11
-K14
22
-K11
Gearbox
Lubricating Pump
(Low Speed)
Heating Element
3 Gearbox
20
previous
REV
DESCRIPTION
.5
A2
T1 /5.4
T2 /5.4
T3 /5.5
T1 /5.2
T2 /5.3
T3 /5.3
21
A1
22
13
21
-K13
-K10
A2
Heating Element
2 Gearbox
Heating Element
1 Gearbox
T1 /5.1
T2 /5.1
T3 /5.1
A1
-K7C
Supp
A1
-K7B
Supp
Supp
A1
-K7A
19
K3
YEL
-K10
-K14
.4
YEL
RD
21
-K12
.4
18
RD
T1 /4.4
T2 /4.4
T3 /4.4
Supp
13
RD
YEL
K14
-P24SW
Supp
RD
YEL
K13
-P24SW
Supp
12
RD
YEL
K12
-P24SW
Supp
RD
YEL
K11
-P24SW
Supp
11
RD
YEL
K10
-P24SW
Supp
-P24SW
RD
YEL
K7
P1
-P24SW
Supp
-P24SW
T1 /4.6
T2 /4.6
T3 /4.6
/5.7
/5.7
/5.7
22
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
21
31
WETC
-P24SW
-P24SW
RD
RD
YEL
-P24SW
RD
YEL
SP02
-P24SW
RD
YEL
SP01
TB1
-P24SW
RD
YEL
SP03
P33
GBXFP
P35
-P24SW
RD
YEL
GBXLP
-P24SW
P36
RD
YEL
YEL
DOEX1
DOEX2
4
PCOM
21
previous
REV
DESCRIPTION
GBX Kidney
Filtration
Pump
DO External
1&2
23
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
22
31
Gen Speed
Sensor 1
-16S1
Yaw Ring
Gear 1
-17S1
out
Yaw Ring
Gear 2
-17S2
out
Yaw Index
Prox
out
out
29.1
29.4
TB7-2A
TB7-5A
29.4
TB7-2B
29.4
29.0
P24A-3A
29.0
P24A-2A
29.5
P24A-1A
29.4
P45C-2A
X4.1-13 (PE)
29.4
29.4
P45C-3A
P45C-2B
29.4
P45C-3B
29.3
P45C-1A
29.3
P45C-1B
29.3
29.3
P45B-2A
P45C
P45B
1
X4.1-12 (PE)
29.3
29.3
P45B-3A
29.3
P45B-1A
P45B-2B
29.3
29.0
P45A-2A
X4.1-11(PE)
29.0
29.0
P45A-3A
P45A-2B
29.0
P45A-3B
P45A
-P24
-4
29.3
-2
P45A-1A
29.3
P47
29.3
GND
Particle
Counter
P45A-1B
P24
X4.1-9 (PE)
Particle
Counter
OK
P24A
1
TB7
-1
-3
-2
-4
-6
-5
-P24
PCOM
Digital Input
YEL
DIN45
Digital Input
YEL
FaultCurrent
Limit
Regulator
DIN48
Counter
Input
YEL
WETA
22
previous
REV
DESCRIPTION
Digital Input
YEL
GENSP
YAWRG1
Digital Input
YEL
YAWRG2
Counter
Input
Counter
Input
YEL
ROTR1
Counter
Input
YEL
PRSP1
YEL
PRSP2
24
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
23
31
SLIPRING
UNIT
29.6
WETA-P27-5A
29.6
Analog
Input
PT100
GEARBOX
BEARING A
TEMPERATURE
WETA-P27-4A
-Chassis
P27
29.6
Analog
Input
PT100
18
WETA-P27-3A
-Chassis
29.6
Analog
Input
PT100
17
WETA-P27-2A
Analog
Input
PT100
16
29.7
-Chassis
15
GEARBOX OIL
SUMP
TEMPERATURE
WETA-P25-17A
14
29.7
13
WETA-P25-16A
29.7
12
GENERATOR
COOLING AIR
TEMPERATURE
WETA-P25-14A
-Chassis
29.7
11
WETA-P25-13A
10
29.7
Analog
Input
PT100
GENERATOR
WINDING
TEMPERATURE 3
WETA-P25-11A
-Chassis
29.7
Analog
Input
PT100
WETA-P25-10A
-Chassis
29.7
GENERATOR
BEARING B
TEMPERATURE
WETA-P25-8A
29.6
Analog
Input
PT100
WETA-P25-7A
-Chassis
29.6
GENERATOR
BEARING A
TEMPERATURE
WETA-P25-5A
29.6
P25
WETA-P25-4A
29.6
GENERATOR
WINDING
TEMPERATURE 2
WETA-P25-2A
29.6
WETA-P25-1A
29.4
30.PT1.2A
29.4
30.PT1.1A
P22
GENERATOR
WINDING
TEMPERATURE 1
-Chassis
6
-Chassis
Analog
Input
PT100
Analog
Input
PT100
WETA
23
previous
REV
DESCRIPTION
25
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
24
31
(Optional)
OUTSIDE
TEMPERATURE 1
OUTSIDE
TEMPERATURE 2
PT100 INPUTS
(Optional)
NACELLE
TEMPERATURE
(Optional)
4 Wire
PT100
ROTOR BEARING
TEMPERATURE
(Optional 4 Wire)
(Optional 4 Wire)
red
red
CONFIG
CUSTOMER PT100
- SPARE 4
CONFIG
CUSTOMER PT100
- SPARE 5
29.2
29.3
P30-2A
P30-3B
29.3
P30
P30-2B
29.2
P30-1A
29.2
P30-1B
TB3
EXC-I
RET-I
-Chassis
EXC-V
RET-V
-Chassis
30.9
30.9
P29C-2A
P29C-3B
30.9
30.9
P29C-1A
6 P29C
P29C-2B
30.9
P29C-1B
29.2
29.2
P29B-5A
5
-Chassis
5 TB4
-Chassis
-Chassis
-Chassis
10
-Chassis
11
12
-Chassis
-Chassis
RET-V
EXC-V
EXC-I
RET-I
EXC-I
RET-I
RET-V
EXC-V
Analog
Input
PT100
P29B-6B
29.2
CONFIG
CUSTOMER PT100
- SPARE 3
wht
P29B-5B
29.2
P29B-4A
6 P29B
29.2
P29B-4B
29.2
P29A-6B
29.2
P29A-5A
P29A-4A
29.2
29.2
wht
P29A-5B
29.2
P29A-4B
P29A
CONFIG
CUSTOMER PT100
- SPARE 2
Analog
Input
PT100
Analog
Input
PT100
Analog
Input
PT100
Analog
Input
PT100
Analog
Input
PT100
Analog
Input
PT100
Analog
Input
PT100
Analog
Input
PT100
WETA
24
previous
REV
DESCRIPTION
26
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
25
31
ALC PROX
135
ALC PROX
45
out
ALC PROX
225
out
Connector
ALC PROX
315
out
+
4
LSS INDEX
PROX
out
+
5
+
10
11
13
12
(Optional)
14
15
16
EXTERNAL OIL
HEATER
TEMPERATURE
EXTERNAL OIL
HEATER
PRESSURE
Two-Wire
Transmitter
Two-Wire
Transmitter
Active
Brake
Pressure
29.1
WETA-P32-14B
WETA-P32-10A
29.1
WETA-P32-14A
TB7-5B 29.1
WETA-P32-10B
29.1
P45B-3B 29.3
29.1
29.1
WETA-P32-6A
P45B-1B 29.3
29.1
WETA-P32-6B
X4.1-1PE 29.1
WETA-P32-2A
29.1
WETA-P32-2B 29.1
WETA-P32-3A
29.1
WETA-P32-3B 29.1
WETA-P32-1A
29.1
WETA-P32-1B 29.1
29.5 WETA-P31-2A
/
29.5 WETA-P31-1A
P24
1
SIG
2
P24
1
SIG
2
CONFIG CUSTOMER
0-20MA ANALOG
SPARE 2
2- or 3-Wire
Transmitter
P31
P32
10
12
11
13
14
15
P34
TB-Chassis
0-20MA
Analog
Input
ICOMD
TB-P24
TB-Chassis
ICOMD
TB-P24
0-20MA
Analog
Input
TB-Chassis
0-20MA
Analog
Input
ICOMD
TB-P24
ICOMD
TB-P24
0-20MA
Analog
Input
TB-Chassis
ICOMD
TB-P24
0-20MA
Analog
Input
TB-Chassis
ICOMD
0-20MA
Analog
Input
TB-P24
TB-Chassis
ICOMD
TB-P24
TB-Chassis
PCOM
TB-P24
0-20MA
Analog
Input
0-20MA
Analog
Input
WETA
25
previous
REV
DESCRIPTION
27
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
26
31
Shield
Rxd (+)
Txd (+)
ADIO
Rxd (-)
Txd (-)
P24
Pcom
P24
Wind Vane
Bit 0-YL90
P24
Wind Vane
Bit 1-YR90
P24
Wind Vane
Bit 2-YL
Common
P24
Wind Vane
Bit 3-YR
Heater Line
Heater Line
12-24 VAC/DC
THIES ULTRASONIC
ANEMOMETER 2D a
(Optional)
12-24 VAC/DC
Heater Neutral
Heater Neutral
Heater Neutral
Heater Neutral
Heater Line
Shield
Com
P24
Shield
P24
Heater Line
12(2)
8(2)
10.9 / 400L2
Com
Anemometer Signal
10.9 / 400N
-X3.1
-Q32
3A
10
30.8
P19
WETA-P19-12A
Sec 24
3
30.8
30.8
WETA-P19-11A
Sec 0
1
J19
WETA-P19-12B
30.8
30.8
WETA-P19-10A
WETA-P19-11B
30.8
30.8
WETA-P19-9A
WETA-P19-10B
30.8
WETA-P19-9B
30.9
30.9
WETA-P19-7A
WETA-P19-8B
30.9
30.9
WETA-P19-6A
WETA-P19-7B
30.9
30.9
WETA-P19-5A
WETA-P19-6B
30.9
WETA-P19-5B
30.9
30.9
WETA-P19-3A
WETA-P19-4B
30.9
WETA-P19-3B
30.9
WETA-P19-2A
24VAC
30.9
30.8
WETA-P19-1A
-T4
WETA-P19-2B
30.8
WETA-P19-1B
Pri 230
230VAC
50/60HZ
Pri 0
POWER SOURCE
FOR HEATERS
24VAC RMS
500VA
11
12
P20
10
11
12
13
14
15
16
17
18
19
20
P21
=TB-P24
=TB-Chassis
TXP
RXP
YEL
=TB-(WETA)FU3
PCOM
27.2
=TB-CHASSIS
=TB-CHASSIS
TXN
PCOM
27.7
CNT 01
RXN
PCOM
=TB-CHASSIS
YEL
Anemometer
Signal
(Analog In)
CNT 02
Digital
Input
Wind Vane
Signal
(Analog In)
Digital
Input
YEL
DIN52
Digital
Input
Digital
Input
YEL
DIN51
YEL
DIN50
Digital
Input
YEL
DIN49
RS-485
COMM PORT
YEL
CNT03
=TB-P24
250V
10 A
=TB-(WETA) FU7
1
Fault Current
Limit Regulator
=TB-(WETA) FU8
1
=TB-(WETA)FU4
250V
10 A
=TB-(WETA)FU5
250V
10 A
WETA
26
previous
REV
DESCRIPTION
28
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
27
31
17
13
10
11
Tower SS RAW
0-20ma
21
Tower FA RAW
0-20ma
12
Tower Osc
0-20ma
15
Tower Osc
Alarm
Tower Vibe
Error
Test Vibe
Monitor
24
P24
Supply
-A2
Shield
WETA-P37-6B
30.5
WETA-P37-6A 30.5
DIN28
Test
Vibration
Monitor
16
17
18
P37
-FU6
Chassis
250VDC
0.315A
-P24
DIN27
0-20MA
Analog
Input
Chassis
ICOMD
YEL
P24
YEL
Digital
Input
24VDC
15
P24
Digital
Input
24VDC
0-20MA
Analog
Input
WETA-P37-2A 30.5
13
-CHASSIS
28.7
30.5
WETA-P37-2B
WETA-P23-15A 30.5
12
ICOMD
-P24
30.5
WETA-P23-13A 30.5
11
WETA-P23-15B
30.5
WETA-P23-12A 30.5
10
WETA-P23-13B
30.5
WETA-P23-11A 30.5
WETA-P23-12B
30.5
WETA-P23-10A 30.5
WETA-P23-8A 30.4
WETA-P23-7A 30.4
7
WETA-P23-11B
30.4
30.4
WETA-P23-10B 30.5
WETA-P23-8B
WETA-P23-7B
30.4
X4.2-22PE
P23
ICOMD
0-20MA
Analog
Input
WETA
27
previous
REV
DESCRIPTION
29
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
28
31
12.0 WETB-J17-3
30.1 WETC-P38-16
-1
-1
-1
-4
4
2
12
11
6
15.5 WETBP10-6A
12.0 WETB-J17-1
15.5 WETBP10-5A
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
15.5 WETBP10-4A
15.6 WETBP10-3A
15.6 WETBP10-2A
15.5 WETBP10-1A
24.6 WETA-P25-17A
24.5 WETA-P25-16A
24.5 WETA-P25-14A
24.5 WETA-P25-13A
24.4 WETA-P25-11A
24.4 WETA-P25-10A
24.3 WETA-P25-8A
24.3 WETA-P25-7A
24.2 WETA-P25-5A
24.2 WETA-P25-4A
24.2 WETA-P25-2A
24.1 WETA-P25-1A
24.8 WETA-P27-5A
24.7 WETA-P27-4A
-3
-4
-3
-4
24.7 WETA-P27-3A
26.0 WETA-P31-2A
24.7 WETA-P27-2A
26.0 WETA-P31-1A
-3
-4
-3
-4
15.3 WETA-P24B-1A
15.3 WETA-P24B-3A
15.3 WETA-P24B-2A
-3
-4
-3
-4
23.5 P24A-1A
24.1 30.PT1.2A
-3
-4
4
2
12
11
6
24.0 30.PT1.1A
17.7 30L-24.1A
30.8 X4.1-14(11)
17.6 30L+24.1A
23.7 TB7-2A
23.5 P45C-2A
-3
-4
Terminal Block
Terminal Block
Terminal Block
-2
-2
-2
TT-2-PE/S1-24DC
Terminal Block
3
1
5
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2o
-2m
-2o
-2m
-2o
-2m
-2o
-2m
P45A-3B 23.3
P45A-2B 23.3
P24B-3 31.2
P24B-2 31.2
WETA-P32-2B 26.1
WETA-P32-3B 26.1
X4.1-1PE 26.2
WETA-P32-1B 26.1
WETA-P32-10B 26.3
WETA-P32-6B 26.2
TB7-5B 26.4
WETA-P32-14B 26.3
S5-1 16.0
P45A-2B 31.3
P45A-3B 31.3
X4.1-9 (PE) 23.3
P45A-1B 23.3
P30-2B 25.4
P30-3B 25.4
P30-1B 25.4
P29B-5B 25.2
P29B-6B 25.3
P29B-4B 25.2
P29A-5B 25.1
P29A-6B 25.1
P29A-4B 25.1
S5-2 16.1
TB7-2B 23.7
X4.1-13 (PE) 23.6
P45C-2B 23.5
P45C-3B 23.5
X4.1-12 (PE) 23.4
P45C-1B 23.4
P45B-2B 23.4
X4.1-11(PE) 23.3
P45B-3B 26.4
P45B-1B 26.4
30L-24.1 =SR/4.6
30L+24.1 =SR/4.6
WETA-P24A-1 =GT/11.3
30.PT1.2 =SR/5.8
SLIPRING
UNIT
30.PT.Sh =SR/5.8
30.PT1.1 =SR/5.7
WETA-P24A-2 =GT/11.3
WETA-P24A-3 =GT/11.3
WETA-P24B-3 =GT/11.8
WETA-P24B-2 =GT/11.9
WETBP10-1 =MCC/8.3
WETA-P25-17 =GE/11.8 GENERATOR
WETA-P25-18 =GE/11.9 COOLING AIR
TEMPERATURE
WETA-P25-16 =GE/11.8
WETA-P25-14 =GE/11.3 GENERATOR
WETA-P25-15 =GE/11.4 WINDING
TEMPERATURE 3
WETA-P25-13 =GE/11.3
WETA-P25-11 =GE/11.7 GENERATOR
WETA-P25-12 =GE/11.7 BEARING B
TEMPERATURE
WETA-P25-10 =GE/11.6
WETA-P25-8 =GE/11.5
GENERATOR
WETA-P25-9 =GE/11.5 BEARING A
TEMPERATURE
WETA-P25-7 =GE/11.5
WETA-P25-5 =GE/11.2
GENERATOR
WETA-P25-6 =GE/11.2 WINDING
TEMPERATURE 2
WETA-P25-4 =GE/11.1
WETA-P25-2 =GE/11.0
GENERATOR
WETA-P25-3 =GE/11.0 WINDING
TEMPERATURE 1
WETA-P25-1 =GE/11.0
GEARBOX
WETA-P27-5 =GT/10.1
BEARING A
WETA-P27-6 =GT/10.1 TEMPERATURE
WETA-P27-4 =GT/10.1
WETA-P27-2 =GT/10.6 GEARBOX OIL
SUMP
WETA-P27-1 =GT/10.7 TEMPERATURE
WETA-P27-3 =GT/10.6
WETA-P31-2 =GT/10.9
Active
Brake
WETA-P31-4 =GT/10.9
Pressure
WETA-P31-1 =GT/10.9
WETA-P24B-1 =GT/11.8
WETBP10-3 =MCC/8.2
WETBP10-2 =MCC/8.3
WETBP10-5 =MCC/8.7
WETBP10-4 =MCC/8.8
WETBP10-6 =MCC/8.2
3
1
5
TT-2-PE/S1-24DC
Terminal Block
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
PT 2-PE/S-24AC-ST
TT-2-PE/S1-24DC
TT-2/2-24DC
TT-2-PE/S1-24DC
TT-2/2-24DC
TT-2-PE-24DC
TT-2/2-24DC
TT-2/2-24DC
TT-2-PE/S1-24DC
TT-2/2-24DC
TT-2-PE/S1-24DC
TT-2/2-24DC
TT-2-PE/S1-24DC
TT-2-PE/S1-24DC
TT-2-PE/S1-24DC
PT 2-PE/S-24AC-ST
TT-2/2-24DC
TT-2/2-24DC
TT-2/2-24DC
TT-2-PE/S1-24DC
TT-2/2-24DC
TT-2-PE/S1-24DC
TT-2/2-24DC
TT-2-PE/S1-24DC
TT-2-PE-24DC
TT-2/2-24DC
TT-2/2-24DC
TT-2/2-24DC
TT-2-PE-24DC
Terminal Block
X4.1
Terminal Block
107W5345P001
DWB
23.5 P45C-3A
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-1o
-1u
-1o
-1u
-1o
-1u
-1o
-1u
Sh
COMP-PART NO.
ISSUED
next
30
29
31
of
B
107W6155
REV
COMP-DRW. NO.
25-APR-2008 G.Stultz
23.4 P45C-1A
23.4 P45B-2A
23.4 P45B-3A
23.4 P45B-1A
23.3 P45A-1A
25.4 P30-2A
25.4 P30-1A
25.2 P29B-5A
25.2 P29B-4A
25.1 P29A-5A
25.1 P29A-4A
16.1 WETB-P5-2
16.0 WETB-P5-1
23.7 TB7-5A
26.3 WETA-P32-14A
26.3 WETA-P32-10A
26.2 WETA-P32-6A
26.1 WETA-P32-2A
26.1 WETA-P32-3A
26.1 WETA-P32-1A
23.5 P24A-2A
23.5 P24A-3A
23.3 P45A-2A
23.3 P45A-3A
X6.3
1.6 xle
Top Box
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
DRAWN
TYPE
COMPONENT
COPYRIGHT 2009 GENERAL ELECTRIC COMPANY
C
COMP NO.
= TB
+
23
3
REVISED BY
22
2
2
CHECKED BY
28
previous
REV
DESCRIPTION
32 33 34
31
21
30
20
29
19
28
18
27
17
26
16
25
15
24
14
13
9
12
8
11
7
10
6
5
4
3
1
1
9
8
7
6
5
4
3
2
1
0
25.3 P29C-2A
25.3 P29C-1A
27.2 WETA-P19-6A
27.1 WETA-P19-2A
27.2 WETA-P19-7A
27.2 WETA-P19-5A
27.2 WETA-P19-3A
27.1 WETA-P19-1A
27.3 WETA-P19-12A
29.4 X4.1-14(11)
27.3 WETA-P19-10A
27.3 WETA-P19-11A
18.5 F5-12
27.3 WETA-P19-9A
31.7 GEN-OB-B
31.7 GEN-OB-A
31.7 GEN-IB-B
31.6 GEN-IB-A
31.6 GB-HS-B
31.6 GB-HS-A
31.5 GB-IS-B
31.5 GB-IS-A
31.5 GB-PS-B
31.4 GB-PS-A
31.4 MB-B
31.4 MB-A
28.6 WETA-P37-6A
28.6 WETA-P37-2A
28.4 WETA-P23-15A
28.3 WETA-P23-13A
28.3 WETA-P23-12A
28.2 WETA-P23-11A
TT-2/2-24DC
WETA-P19-2B 27.1
WETA-P19-7B 27.2
WETA-P19-8B 27.3
WETA-P19-5B 27.2
WETA-P19-3B 27.2
WETA-P19-4B 27.2
WETA-P19-1B 27.1
TT-2-PE/S1-24DC
TT-2-PE/S1-24DC
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
WETA-P19-12B 27.3
WETA-P19-10B 27.3
-4
TT-2-PE/S1-24DC
3
1
5
P29C-2B 25.3
P29C-3B 25.3
P29C-1B 25.3
WETA-P19-6B 27.2
PT 2-PE/S-24AC-ST
WETA-P19-11B 27.3
WETA-P19-9B 27.3
-3
-3
-4
-3
-4
-3
-4
4
2
12
11
6
3
1
5
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
PT 2-PE/S-24AC-ST
TT-2-PE/S1-24DC
TT-2-PE/S1-24DC
TT-2-PE/S1-24DC
TT-2-PE/S1-24DC
TT-2-PE/S1-24DC
TT-2-PE/S1-24DC
TT-2-PE-24DC
Terminal Block
TT-2-PE-24DC
WETA-P23-15B 28.4
WETA-P23-13B 28.3
TT-2-PE-24DC
TT-2-PE-24DC
WETA-P23-12B 28.3
WETA-P23-11B 28.2
TT-2-PE-24DC
TT-2-PE-24DC
TT-2-PE-24DC
WETC-P26-1 =GT/11.5
WETA-P23-10B 28.2
WETA-P23-8B 28.1
X4.2-22PE 28.1
WETA-P23-7B 28.1
TT-2-PE-24DC
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
WETC-P28-12 19.7
TT-2-PE-24DC
TT-2-PE-24DC
-2
WETC-P28-11 19.7
-2
Terminal Block
-2
WETC-P28-10 19.7
WETC-P26-3 =GT/11.4
WETC-P26-2 =GT/11.5
WETC-P26-5 =GT/11.1
WETC-P26-4 =GT/11.4
WETC-P26-7 =GT/11.0
WETC-P26-6 =GT/11.2
WETC-P26-9 =GT/11.7
WETC-P26-8 =GT/11.1
WETC-P26-10 =GT/11.7
WETC-P26-11 =GT/11.7
Terminal Block
-2
WETC-P28-9 19.6
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
WETA-P37-6B 28.6
WETA-P37-2B 28.6
4
2
12
11
6
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-3
-4
-1
28.1 WETA-P23-8A
28.2 WETA-P23-10A
28.1 WETA-P23-7A
-3
-4
-4
19.3 WETC-P26-11A
19.3 WETC-P26-10A
19.3 WETC-P26-9A
19.2 WETC-P26-8A
19.2 WETC-P26-7A
Terminal Block
-2
INTERMEDIATE STAGE
PLANTETARY STAGE
MAIN BEARING
DWB
-3
-4
Terminal Block
WETC-P28-8 =GT/12.6
WETC-P28-7 =GT/12.6
WETC-P28-6 =GT/12.1
WETC-P28-5 =GT/12.1
WETC-P28-4 =GT/12.5
WETC-P28-3 =GT/12.5
WETC-P28-2 =GT/12.5
WETC-P28-1 =GT/12.4
WETC-P38-16 29.8
WETC-P38-15 18.5
MPSW1 =GE/9.1
MPSW2 =GE/9.1
GE-X6-4 =GE/10.8
GE-X6-1 =GE/10.6
P17D-2 20.4
P17D-1 20.4
P17C-2 20.4
P17C-1 20.4
P17B-2 20.3
P17B-1 20.3
P17A-2 20.3
P17A-1 20.3
107W5345P001
ISSUED
19.2 WETC-P26-6A
-3
TT-2-PE-24DC
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
-2
-PE
-1
COMP-PART NO.
25-APR-2008 G.Stultz
-3
-4
19.0 WETC-P26-1A
-1
-3
-4
19.7 WETC-P28-12A
-1
TT-2-PE-24DC
TT-2-PE-24DC
TT-2-PE-24DC
TT-2-PE-24DC
TT-2-PE-24DC
TT-2-PE-24DC
TT-2-PE-24DC
TT-2-PE-24DC
TT-2-PE-24DC
TT-2-PE-24DC
Sh
30
31
of
B
107W6155
REV
COMP-DRW. NO.
DRAWN
19.1 WETC-P26-5A
19.1 WETC-P26-4A
19.1 WETC-P26-3A
19.7 WETC-P28-11A
-1
19.1 WETC-P26-2A
19.7 WETC-P28-10A
-1
-3
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-3
-4
-4
19.6 WETC-P28-9A
19.6 WETC-P28-8A
19.6 WETC-P28-7A
19.6 WETC-P28-6A
19.5 WETC-P28-5A
19.5 WETC-P28-4A
19.5 WETC-P28-3A
19.5 WETC-P28-2A
19.4 WETC-P28-1A
18.5 WETC-P38-16A
18.5 WETC-P38-15A
18.4 MPSW1A
18.4 MPSW2A
18.7 GE-X6-4A
18.7 GE-X6-1A
20.4 P17D-2A
20.4 P17D-1A
20.4 P17C-2A
20.4 P17C-1A
20.3 P17B-2A
20.3 P17B-1A
20.3 P17A-2A
20.3 P17A-1A
1.6 xle
Top Box
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
See Revision History.
GE Energy
COMP NO.
= TB
+
TYPE
COMPONENT
COPYRIGHT 2009 GENERAL ELECTRIC COMPANY
C
GENERAL ELECTRIC COMPANY
WIND ENERGY TECHNOLOGY
REVISED BY
CHECKED BY
next
31
29
previous
REV
DESCRIPTION
A
B
A
B
4
21
2
20
B
A
6
1
25
24
23
22
21
19
20
18
26
17
25
16
24
12 13 14 15
23
11
22
10
9
8
7
6
5
4
3
2
1
X4.3
X5.1
X4.2
9
8
7
6
5
4
3
2
1
0
OPTION
GEN OB
30.7
30.7
GEN-OB-B
GEN-OB-A
PE
30.7
GEN-IB-B
30.7
PE
30.7
30.7
GB-HS-B
GB-HS-A
30.7
GB-IS-B
PE
GEN IB
GEN-IB-A
GB HS
30.6
PE
30.6
GB-PS-B
30.6
PE
GB-PS-A
GB IS
GB-IS-A
GB PS
30.6
PE
MB-A
COM
SIG
29.3
PE
MB
P45A-3B
COM
SIG
P24B-2
PE
KPH (HS)
29.3
KPH (LS)
P45A-2B
V1-
29.0
12.9 / CBM-V1-
P24B-3
V1+
29.0
12.5 / CBM-V1+
ENET
Port B
MB-B
-3701-CBM
30.6
13.2
CBM-ETH
OPTION
30
previous
REV
DESCRIPTION
=GT/1
CHECKED BY
REVISED BY
02-NOV-2010, 02-NOV-2010,
M. MENNIS
B.FERGUSON
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Top Box
COMP NO.
COMP-DRW. NO.
107W6155
COMP-PART NO.
107W5345P001
REV
next
= TB
+
Sh
of
31
31
Cover Page
GE Wind Energy 1.6MW
WTG Drw No.:
WTG No.:
Project/CMS No.:
Customer:
Component:
Comp No.:
Comp-Drw. No.:
Comp-Part No.:
Frequency:
Rated Voltage:
Control Voltage:
108W6614
16111805 - 813
Aratua-1 / 712835
BioEnergy
Gearbox 60 Hz
104W3892
104W3938P001 SLE, 104W3943P001 XLE
60Hz
690V / 230V
24V DC
2
DATE
=TB/31
previous
REV
DESCRIPTION
ECR3036053
CHECKED BY
SEE PLM
REVISED BY
GE Energy
SEE PLM
DRAWN
ISSUED
15-JAN-2007 B.LUETTE
15-JAN-2007 S.KLUEMPER
SIGNATURE
ENGINEER
15-JAN-2007 H.GRUENWALDT
DRAWN
15-JAN-2007 B.LUETTE
CHECKED
15-JAN-2007 M.SCHLINGE
ISSUED
15-JAN-2007 S.KLUEMPER
next
GE Energy
Gearbox 60 Hz
1.x 60Hz CWE ESS
UL/CSA
COMPONENT
TYPE
1.6 xle
Gearbox 60 Hz
COMP NO.
= GT
+
COMP-DRW. NO.
104W3892
COMP-PART NO.
104W3938P001
REV
Sh
of
1
14
date
ECR3036053
revision
change
actual state
1-20
New drawing
19.APR.2007
Cross references
1-14
27.SEP.2007
Temperatures
1,10,11
09.OCT.2008
10-14
New frame
1-14
Drive values
13
Heater values
14
New frame
1-14
Updated Connections
10-14
page
15.JAN.2007
24.MAR.2009
1
previous
REV
DESCRIPTION
04.JAN.2010
4 & 4a
02.MAR.2011
PE Terminal added
4a
11
14
ECR3036053
3
CHECKED BY
SEE PLM
REVISED BY
GE Energy
SEE PLM
DRAWN
15-JAN-2007 B.LUETTE
ISSUED
15-JAN-2007 S.KLUEMPER
Modification information
COMPONENT
TYPE
1.6 xle
Gearbox 60 Hz
COMP NO.
COMP-DRW. NO.
104W3892
COMP-PART NO.
104W3938P001
REV
next
= GT
+
Sh
of
2
14
Terminals
Voltage
(Mindestquerschnitt !)
(Min. cross section !)
-X2
690V
-X4
-X6
-X7
230V
24V
measuring transmitter
Hauptstromkreise/Main circuits
Wechselspannung/AC voltage
Gleichspannung/DC voltage
schwarz/black
schwarz/black
16AWG (1,5mm)
16AWG (1,5mm)
Neutralleiter/Neutral conductors
hellblau/light blue
16AWG (1,5mm)
Steuerstromkreise/Control circuit
Wechselspannung/AC voltage
Gleichspannung/DC voltage
rot/red
dunkelblau/dark blue
18AWG (1mm)
18AWG (1mm)
orange
18AWG (1mm)
Ortskennzeichnung
Kabel-Nr.
Bezeichnung
Plant
designation
Positiondesignation
Cable-No.
Designation
34
Getriebe
gearbox
=GT
TB1
Klemmkasten 1 ( Steuerung )
terminal box 1 ( Control unit )
TB2
Klemmkasten 2 ( Leistung )
terminal box 2 ( Power )
W3034.##
Kabelverbindung vom Getriebe zur Hydraulik/Cable connection from gearbox to hydraulic ->
W3437.##
2
previous
REV
DESCRIPTION
ECR3036053
CHECKED BY
SEE PLM
REVISED BY
GE Energy
SEE PLM
DRAWN
15-JAN-2007 B.LUETTE
ISSUED
15-JAN-2007 S.KLUEMPER
4
general information
COMPONENT
TYPE
1.6 xle
Gearbox 60 Hz
COMP NO.
COMP-DRW. NO.
104W3892
COMP-PART NO.
104W3938P001
REV
next
= GT
+
Sh
of
3
14
Unten / Bottom
PL20
PL16
PL16
PL25
99
PL25
PL25
45
PL25
120
Beschreibung / Description
PL= Verschlustopfen / Plug
CG= Verschraubung / Cable Gland
40
80
120
KL1589.510 (400x150x120)
150
7o
6o
PE
5o
4o
3o
2o
1o
-X7
15o
14o
PE
PE
13o
12o
9o
8o
11o
10o
7o
6o
5o
4o
3o
2o
1o
-X6
=GT+TB1
Component
Gearbox junction boxes
Cable glands
Plugs
IP class
NEMA
UL type class
54
54
54
12
12
12
3R
3R
3R
7m
8m
9m
10m
11m
12m
13m
14m
15m
1m
2m
3m
4m
7u
8u
9u
10u
11u
12u
13u
14u
15u
1u
2u
3u
4u
7m
6m
6u
7u
5m
5u
6m
4m
4u
6u
3m
3u
5m
2m
5u
1m
2u
Gearbox junction boxes and equipment must be designed in accordance with UL 805 / CSA / CCC / CE
Gearbox junction boxes and equipment must fulfill IP / NEMA / UL and UL type classes as specified below
1u
Manufacturer must meet the requirements of IEC 529 / EN 60 and international protection codes ( IP classes)
400
Oben / Top
400
90
65
25
40
3
previous
REV
DESCRIPTION
ECR3036053
PL16
PL16
CG16
CG16
PL20
99
120
60
CG20
CG20
CG20
CG16
PL16
CG16
PL20
PL32
4a
CHECKED BY
SEE PLM
REVISED BY
GE Energy
SEE PLM
DRAWN
04-JAN-2010, R.SHAW
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Gearbox 60 Hz
COMP NO.
COMP-DRW. NO.
104W3892
COMP-PART NO.
104W3938P001
REV
next
= GT
+
Sh
of
4
14
Unten / Bottom
PL20
PL20
PL20
PL20
PL20
PL20
PL20
PL20
PL20
PL20
25
PL20
60
99
PL20
120
Beschreibung / Description
PL= Verschlustopfen / Plug
CG= Verschraubung / Cable Gland
40
30
30
25
25
25
25
25
25
25
30
30
65
KL1589.510 (400x150x120)
150
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
-X4
Manufacturer must meet the requirements of IEC 529 / EN 60 and international protection codes ( IP classes)
-X2
=GT+TB2
Gearbox junction boxes and equipment must be designed in accordance with UL 805 / CSA / CCC / CE
Gearbox junction boxes and equipment must fulfill IP / NEMA / UL and UL type classes as specified below
Component
Gearbox junction boxes
Cable glands
Plugs
IP class
NEMA
UL type class
54
54
54
12
12
12
3R
3R
3R
400
Oben / Top
400
80
60
25
40
4
previous
REV
DESCRIPTION
ECR3036053
PL20
PL16
CG16
CG16
PL16
PL25
99
120
60
PL25
PL25
PL16
CG16
CG16
PL25
PL25
5
CHECKED BY
SEE PLM
REVISED BY
GE Energy
SEE PLM
DRAWN
04-JAN-2010, R.SHAW
ISSUED
DWB
COMPONENT
TYPE
1.6 xle
Gearbox 60 Hz
COMP NO.
COMP-DRW. NO.
104W3892
COMP-PART NO.
104W3938P001
REV
next
= GT
+
Sh
of
4a
14
Contents
Page
Page designation
Date
User.
=GT+/1
cover page
1/5/2010
501557572
=GT+/2
Modification information
1/5/2010
501557572
=GT+/3
general information
1/5/2010
501557572
=GT+/4
1/5/2010
501557572
=GT+/4a
1/5/2010
501557572
=GT+/5
Contents
3/24/2009
501557572
=GT+/10
Temprerature sensors
1/5/2010
501557572
=GT+/11
1/5/2010
501557572
=GT+/12
1/5/2010
501557572
=GT+/13
Drives 690V
1/5/2010
501557572
=GT+/14
Heaters 690V/230V
1/5/2010
501557572
4a
previous
REV
DESCRIPTION
ECR3036053
10
CHECKED BY
SEE PLM
REVISED BY
GE Energy
SEE PLM
DRAWN
15-JAN-2007 B.LUETTE
ISSUED
15-JAN-2007 S.KLUEMPER
Contents
COMPONENT
TYPE
1.6 xle
Gearbox 60 Hz
COMP NO.
COMP-DRW. NO.
104W3892
COMP-PART NO.
104W3938P001
REV
next
= GT
+
Sh
of
5
14
10B1.1
10B3.1
-10B4
P
I
-9X1
sh1
2u
3o
3m
3u
4o
ECR3036053
4u
5o
5m
5u
bn
wh
sh2
6o
6m
6u
sh
-W3034.02
2x18 AWG
GBX15
temperature
oil sump
bearing temperature A
rotor
5
previous
REV
DESCRIPTION
4m
PE
bn
bu
sh
7o
7m
7u
wh
bn
sh
=TB/29.5 / WETA-P31-4
ye
2m
-W3437.01
2x18 AWG
=TB/29.5 / WETA-P31-1
gn
2o
sh
1u
=TB/29.6 / WETA-P27-1
1m
=TB/29.6 / WETA-P27-3
1o
-W34.03
2x19 AWG
=TB/29.6 / WETA-P27-2
sh
=TB/29.6 / WETA-P27-4
-W3034.01
2x2x22 AWG
GBX14
=TB/29.6 / WETA-P27-6
-X7
=TB/29.6 / WETA-P27-5
-W34.01
2x19 AWG
free
0V
=TB/29.5 / WETA-P31-2
+UB
4-20mA
+
pressure transducer
active break
pressure accumulator
11
CHECKED BY
SEE PLM
REVISED BY
GE Energy
SEE PLM
DRAWN
15-JAN-2007 B.LUETTE
ISSUED
15-JAN-2007 S.KLUEMPER
Temprerature sensors
COMPONENT
TYPE
1.6 xle
Gearbox 60 Hz
COMP NO.
COMP-DRW. NO.
104W3892
COMP-PART NO.
104W3938P001
REV
next
= GT
+
Sh
of
10
14
Option
-11B1
-11B2
P
2
-11S1
2
3
-
-11S3
13
-11S2
14
-11S4
3
-
-X6
BN
BU
BK
SH
1o
1m
1u
2o
2m
2u
3o
3m
3u
PE
4o
4m
4u
5o
5m
5u
-W34.10
Initiator
3x19 AWG
-W34.09
3x19 AWG
-W34.08
3x19 AWG
-W34.07
2x19 AWG
-W34.06
Initiator
3x19 AWG
-W34.05
3x19 AWG
-W34.04
3x19 AWG
-11B3
BN
BU
BK
SH
6o
6m
6u
7o
7m
7u
PE
PE
10
previous
REV
DESCRIPTION
ECR3036053
rotor
speed
sensor 1
Level switch
overtemperature
gear box
pressure switch
gear box
=TB/29.5 / WETA-P24B-2
10
=TB/29.5 / WETA-P24B-3
11
=TB/29.5 / WETA-P24B-1
=TB/30.4 / WETC-P26-10
=TB/30.4 / WETC-P26-11
=TB/30.4 / WETC-P26-9
=TB/30.3 / WETC-P26-4
=TB/30.3 / WETC-P26-3
=TB/29.5 / WETA-P24A-2
=TB/29.5 / WETA-P24A-3
=TB/29.5 / WETA-P24A-1
=TB/30.3 / WETC-P26-2
=TB/30.4 / WETC-P26-6
=TB/30.3 / WETC-P26-5
=TB/30.4 / WETC-P26-7
=TB/30.4 / WETC-P26-8
-W3034.03
12x18 AWG
GBX12
=TB/30.3 / WETC-P26-1
-W3034.04
7x18 AWG
GBX13
PE
rotor
speed
sensor 2
12
CHECKED BY
SEE PLM
REVISED BY
GE Energy
SEE PLM
DRAWN
15-JAN-2007 B.LUETTE
ISSUED
15-JAN-2007 S.KLUEMPER
COMPONENT
TYPE
1.6 xle
Gearbox 60 Hz
COMP NO.
COMP-DRW. NO.
104W3892
COMP-PART NO.
104W3938P001
REV
next
= GT
+
Sh
of
11
14
gn/ye
bn
bk
8o
8m
8u
9o
9m
9u
10o
10m
10u
11o
11m
pressure switch
hydraulic
11
previous
REV
DESCRIPTION
ECR3036053
solenoid valve
rotor brake
pressure limitation
valve 22
solenoid valve
rotor brake
pressure delayed
valve 21
=TB/30.2 / WETC-P28-2
=TB/30.1 / WETC-P28-1
=TB/12.2 / WETB-P7-5
=TB/12.1 / WETB-P7-1
=TB/12.4 / WETB-P7-8
=TB/12.4 / WETB-P7-4
=TB/30.2 / WETC-P28-6
=TB/30.2 / WETC-P28-5
brake worn
warning 8mm
11u
wh
bu
12o
12m
12u
gn/ye
gn/ye
gn/ye
13o
13m
13u
14o
14m
14u
15o
15m
15u
Brake
wearing
failure 10mm
brake opened
solenoid valve
rotor brake
pressure undelayed
to brake
valve 20
=TB/12.3 / WETB-P7-6
=TB/12.2 / WETB-P7-2
gn/ye
A2
-W3437.08
3x18 AWG
A2
=TB/12.4 / WETB-P7-7
A1
-12Y4
14
-W3437.06
3x18 AWG
A1
-12Y3
bk
-W3437.05
4x18 AWG
-W3437.04
3x18 AWG
bu
13
-12B3
A2
-W3437.03
3x18 AWG
A2
bn
-12S1
-W3034.06
12x18 AWG
GBX16
-W3034.05
12x18 AWG
GBX17
wh
-12Y2
-W3437.02
3x18 AWG
-X6
A1
-12Y1
=TB/12.3 / WETB-P7-3
A1
-W3437.07
3x18 AWG
-12B1
=TB/30.2 / WETC-P28-8
=TB/30.2 / WETC-P28-7
=TB/30.2 / WETC-P28-4
=TB/30.2 / WETC-P28-3
solenoid valve
rotor brake
pressure complete
to the tank
valve 23
13
CHECKED BY
SEE PLM
REVISED BY
GE Energy
SEE PLM
DRAWN
15-JAN-2007 B.LUETTE
ISSUED
15-JAN-2007 S.KLUEMPER
COMPONENT
TYPE
1.6 xle
Gearbox 60 Hz
COMP NO.
COMP-DRW. NO.
104W3892
COMP-PART NO.
104W3938P001
REV
next
= GT
+
Sh
of
12
14
GN/YE
GN/YE
GN/YE
rotation speed 1
rotation speed 2
ECR3036053
PE
GN/YE
10
11
12
13
14
15
16
GN/YE
GN/YE
rotation speed 1
oil cooler
gear box
12
previous
REV
DESCRIPTION
U1
=TB/6.2 / K10-T1
-W3034.09
4x16 AWG
GBX4
=TB/6.8 / K13-PE
=TB/6.6 / K11-PE
=TB/6.8 / K13-T1
-W3034.08
4x16 AWG
GBX7
-W34.12
7X14 AWG
V1
M
3~
690V 60Hz
1550U/min
W1
PE
-W3034.10
4x16 AWG
GBX5
-W3437.09
4X16 AWG
-W3034.11
4x16 AWG
GBX8
GN/YE
17
18
19
20
GN/YE
=TB/4.2 / K3-PE
-13M3
=TB/4.2 / K3-T3
U2
=TB/4.1 / K3-T2
V2
=TB/4.1 / K3-T1
PE
W2
=TB/6.4 / K12-PE
U1
=TB/6.8 / K13-T3
V1
=TB/6.8 / K13-T2
W1
=TB/6.6 / K11-T1
-W3034.07
4x16 AWG
GBX6
U2
=TB/6.6 / K11-T3
+TB2 -X2
V2
=TB/6.6 / K11-T2
-W34.11
7X16 AWG
W2
=TB/6.4 / K12-T3
-13M2
690V/60HZ
4,2/7,2kW
6,5A/8,1A
860/1720U/min
=TB/6.4 / K12-T2
-13M1
690V/60HZ
1,8/3,6kW
3,2A/4,8A
1160/1740U/min
=TB/6.4 / K12-T1
=TB/6.2 / K10-PE
=TB/6.2 / K10-T3
=TB/6.2 / K10-T2
rotation speed 2
gear box
lubrication pump
rotor brake
hydraulic pump
14
CHECKED BY
SEE PLM
REVISED BY
GE Energy
SEE PLM
DRAWN
15-JAN-2007 B.LUETTE
ISSUED
15-JAN-2007 S.KLUEMPER
Drives 690V
COMPONENT
TYPE
1.6 xle
Gearbox 60 Hz
COMP NO.
COMP-DRW. NO.
104W3892
COMP-PART NO.
104W3938P001
REV
next
= GT
+
Sh
of
13
14
option!
28
GN/YE
-W3034.14
4x16 AWG
GBX3
GN/YE
29
30
31
32
GN/YE
-W34.16
3x16 AWG
GN/YE
+TB2 -X4
GN/YE
-W3034.15
3x16 AWG
GBX9
-W34.17
3x16 AWG
-W3034.16
3x16 AWG
GBX10
L1
GN/YE
GN/YE
13
previous
REV
DESCRIPTION
ECR3036053
heating element 2
heating element 3
(option)
cooler motor
heater
-W3437.10
3x16 AWG
-W3034.17
3x16 AWG
GBX11
GN/YE
GN/YE
=TB/9.9 / J8-PE3
27
=TB/9.9 / WETB-J8-12
26
L1
=TB/9.8 / WETB-J8-5
-W3034.13
4x16 AWG
GBX2
25
-W34.15
4x16 AWG
=TB/9.6 / J8-PE2
GN/YE
GN/YE
230V/60Hz
2AC
-14E6
=TB/9.6 / WETB-J8-10
L1
=TB/9.8 / J8-PE1
L3
230V/60Hz
2AC/28W/0,12A
-14E5
=TB/9.7 / WETB-J8-11
L2
=TB/5.5 / K7C-PE
24
L1
=TB/5.4 / K7C-T2
23
-14E4
=TB/5.4 / K7C-T1
22
L3
=TB/5.3 / K7B-PE
21
-W34.14
4x16 AWG
L2
=TB/5.3 / K7B-T3
GN/YE
=TB/5.1 / K7A-PE
=TB/5.1 / K7A-T1
-W3034.12
4x16 AWG
GBX1
L1
=TB/5.1 / K7A-T3
+TB2 -X2
L3
=TB/5.1 / K7A-T2
-W34.13
4x16 AWG
L2
=TB/5.2 / K7B-T1
L1
230V/60Hz
2AC/28W/0,12A
-14E3
=TB/5.5 / K7C-T3
-14E2
=TB/5.3 / K7B-T2
-14E1
690V/60Hz/3AC
=TB/9.6 / WETB-J8-1
690V/60Hz/3AC
=TB/9.7 / WETB-J8-3
690V/60Hz/3AC
option!
lubrication pump motor
heater
hydraulic pump
heater
=GE/1
CHECKED BY
SEE PLM
REVISED BY
GE Energy
SEE PLM
DRAWN
15-JAN-2007 B.LUETTE
ISSUED
15-JAN-2007 S.KLUEMPER
Heaters 690V/230V
COMPONENT
TYPE
1.6 xle
Gearbox 60 Hz
COMP NO.
COMP-DRW. NO.
104W3892
COMP-PART NO.
104W3938P001
REV
next
= GT
+
Sh
of
14
14
Cover Page
GE Wind Energy 1.6MW
WTG Drw No.:
WTG No.:
Project/CMS No.:
Customer:
BioEnergy
Component:
Comp No.:
Generator
Comp-Drw. No.:
Comp-Part No.:
Frequency:
Rated Voltage:
Control Voltage:
108W6614
16111805 - 813
Aratua-1 / 712835
104W2742
108W5204P001, 108W2002P001, 108W202P002, 108W5204P002: 50Hz
107W2741P001, 107W8042P001, 108W5211P001, 108W5211P101,
108W5201P001:60Hz
50 / 60Hz
690V / 230V
24V DC
DATE
SIGNATURE
=GT/14
previous
REV
DESCRIPTION
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
ISSUED
25-APR-2008 G.Stultz
DWB
cover page
next
GE Energy
DRAWN
25-APR-2008 G.Stultz
CHECKED
25-APR-2008
ENGINEER
12-SEPT-2007 T. Klodowski
ISSUED
DWB
Generator
1.x 50/60Hz
A. Ridenour
W930
COMPONENT
TYPE
Generator
COMP NO.
= GE
+
1.x 50/60Hz
REV
COMP-DRW. NO.
104W2742
COMP-PART NO.
108W5204P001
Sh
of
1
11
date
revision
change
page
09/12/07
New Release
03/13/09
10, 11
11/03/09
4, 5
2/18/2011
1,4,5,10
1
previous
REV
DESCRIPTION
actual state
ECR3036113/
ECO1101479
3
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
Modification information
COMPONENT
TYPE
Generator 1500kW
COMP NO.
COMP-DRW. NO.
104W2742
COMP-PART NO.
104W2741P001
next
= GE
+
REV
Sh
of
2
11
Main circuits
AC voltage
DC voltage
black
black
16AWG (1,5mm)
16AWG (1,5mm)
Neutral conductors
light blue
16AWG (1,5mm)
Control circuit
AC voltage
DC voltage
red
dark blue
18AWG (1mm)
18AWG (1mm)
orange
16AWG (1,5mm)
Positiondesignation
Cable-No.
=GE
Designation
36
Generator 1500kW
terminals
voltage
-X1
-X2
-X3
-X4
-X5
-X6
-X7
-X8
-X9
-X10
W1230.##
2
previous
REV
DESCRIPTION
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
W3260.##
GENERAL ELECTRIC COMPANY
WIND ENERGY TECHNOLOGY
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
general information
COMPONENT
TYPE
Generator 1500kW
COMP NO.
COMP-DRW. NO.
104W2742
COMP-PART NO.
104W2741P001
next
= GE
+
REV
Sh
of
3
11
STATOR
-V
-W
-PE
1
OPTION 1
bk
PE
PE
bk
bk
bk
bk
OPTION 1
L2
=CFC/5.8 / 1PE.6.1
=CFC/5.8 / 1L3.6.4
=CFC/5.8 / 1L3.6.3
bk
=CFC/5.8 / 1L3.6.2
=CFC/5.8 / 1L3.6.1
=CFC/5.8 / 1L2.6.4
=CFC/5.8 / 1L2.6.3
OPTION 1
L1
OPTION 1
bk
=CFC/5.8 / 1L2.6.2
=CFC/5.8 / 1L2.6.1
=CFC/5.8 / 1L1.6.4
=CFC/5.8 / 1L1.6.3
bk
=CFC/5.8 / 1L1.6.2
=CFC/5.8 / 1L1.6.1
bk
bk
bk
grounding
divided
into
base frame
OPTION 1
L3
PE
5
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
Generator connection
COMPONENT
TYPE
Generator 1500kW
COMP NO.
COMP-DRW. NO.
104W2742
COMP-PART NO.
104W2741P001
next
= GE
+
REV
Sh
of
4
11
ROTOR
*
-L
=CFC/4.2 / M.6.3
-M
=CFC/4.2 / M.6.2
-PE
1
OPTION 1
grounding
divided
into
base frame
bk
PE
PE
=CFC/4.2 / M.6.1
=CFC/4.2 / L.6.3
bk
=CFC/4.1 / L.6.2
=CFC/4.1 / L.6.1
=CFC/4.1 / K.6.3
bk
=CFC/4.1 / K.6.2
bk
=CFC/4.0 / K.6.1
bk
=CFC/4.0 / 1PE.6.2
OPTION 1
OPTION 1
OPTION 1
frequency converter
4
previous
REV
DESCRIPTION
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
6
Generator connection
COMPONENT
TYPE
Generator 1500kW
COMP NO.
COMP-DRW. NO.
104W2742
COMP-PART NO.
104W2741P001
next
= GE
+
REV
Sh
of
5
11
13
-6Q1
/9.1
I>
I>
I>
I>
K5-PE
=TB/4.7
=TB/4.6
K5-T3
K5-T2
=TB/4.6
=TB/4.6
K5-T1
-M1
690V
50/60Hz
U1
V1
W1
PE
-16AWG
5
previous
REV
DESCRIPTION
-16AWG
-16AWG
-16AWG
Oelflex
4x
-16AWG
-16AWG
-16AWG
I>
-16AWG
I>
-14AWG
-14AWG
Oelflex
4x
-14AWG
13
14
PE
-14AWG
/9.1
14
-PE1
X2
-6Q2
10
U1
M
3~
690V
50/60Hz
generator fan
internal cooling
circuit 1
12
W1
M
3~
-M2
PE
V1
11
PE
option
generator fan
internal cooling
circuit 2
7
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
Generator connection
COMPONENT
TYPE
Generator 1500kW
COMP NO.
COMP-DRW. NO.
104W2742
COMP-PART NO.
104W2741P001
next
= GE
+
REV
Sh
of
6
11
13
-7Q1
/9.1
13
/9.1
14
14
I>
I>
I>
-16AWG
-16AWG
-16AWG
-16AWG
I>
-16AWG
I>
-16AWG
I>
-14AWG
-14AWG
-14AWG
-7Q2
PE
PE
-PE1
3
K4-PE
=TB/4.4
=TB/4.4
K4-T3
=TB/4.4
K4-T2
=TB/4.4
K4-T1
-M3
690V
50/60Hz
external fans
power supply 690V
6
previous
REV
DESCRIPTION
U1
V1
W1
-16AWG
-14AWG
10
11
12
-16AWG
X2.1
U1
M
3~
-M4
690V
50/60Hz
PE
generator fan
external cooling
circuit 1
V1
W1
M
3~
PE
option
generator fan
external cooling
circuit 2
8
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
Generator connection
COMPONENT
TYPE
Generator 1500kW
COMP NO.
COMP-DRW. NO.
104W2742
COMP-PART NO.
104W2741P001
next
= GE
+
REV
Sh
of
7
11
-8E1
U=690V
f=50/60Hz
-16AWG
2
=TB/5.7
K6-PE
-16AWG
K6-T3
=TB/5.7
-16AWG
-16AWG
=TB/5.7
-16AWG
X2.2
K6-T1
PE
L2
-16AWG
L1
generator
standby heater
7
previous
REV
DESCRIPTION
9
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
standby heater
COMPONENT
TYPE
Generator 1500kW
COMP NO.
COMP-DRW. NO.
104W2742
COMP-PART NO.
104W2741P001
next
= GE
+
REV
Sh
of
8
11
13
Option
-7Q2
/7.5
14
13
Option
-6Q2
/6.5
14
13
-7Q1
/7.3
14
13
-6Q1
/6.3
=TB/30.1
MPSW2
=TB/30.1
MPSW1
-18AWG
X6.1
-18AWG
-18AWG
Oelflex
4x
14
8
previous
REV
DESCRIPTION
10
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
Generator connection
COMPONENT
TYPE
Generator 1500kW
COMP NO.
COMP-DRW. NO.
104W2742
COMP-PART NO.
104W2741P001
next
= GE
+
REV
Sh
of
9
11
-7B1
Leine & Linde 862-228157-2048 - 50Hz
Leine & Linde 862-228157-3072 - 60Hz
Note:
For alternate
encoder connections
refer to 108W5261
K1
K1-
K2
K2-
K0
K0-
XSG1
Us
0V
UB+ 0V-
Sh
power brushes
earthing
brushes
sh
=TB/30.1
GE-X6-4
=TB/30.1
=MCC/11.8 / K0q
con2
GE-X6-1
=MCC/11.8 / +24
con1
=MCC/11.8 / Shld
con4
=MCC/11.8 / Com
con3
=MCC/11.8 / K0
con8
=MCC/11.8 / K2q
con7
=MCC/11.8 / K2
con6
=MCC/11.8 / K1q
con5
2x18AWG
2x1mm
X6
=MCC/11.8 / K1
-22AWG
Li12YC11Y-HF(TP)
4x2x
1x18AWG
Clockwise
From
Shaft Side
1x18AWG
Note:
generator
brush wear
generator
rotary encoder
9
previous
REV
DESCRIPTION
11
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
rotation speed /
brush wear
COMPONENT
TYPE
Generator 1500kW
COMP NO.
COMP-DRW. NO.
104W2742
COMP-PART NO.
104W2741P001
next
= GE
+
REV
Sh
of
10
11
-11B1
1
-11B1.1
-11B2
10
wh
bn
gn
11
12
13
-11B3
14
15
16
18
wh
19
20
21
22
23
24
25
27
28
29
-11B5
30
31
32
33
-11B5.1
34
35
36
37
38
39
40
-11B6
-1B6.1
41
42
43
gn
rd
gy
pk
44
45
46
47
=TB/29.7 / WETA-P25-18
=TB/29.7 / WETA-P25-17
generator
bearing temperature B
generator
cooling
air temperature 1
=SR/1
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
winding temperature
bearing temperature
COMPONENT
TYPE
COMP-DRW. NO.
104W2742
COMP-PART NO.
104W2741P001
next
= GE
+
Generator 1500kW
COMP NO.
48
ye
=TB/29.7 / WETA-P25-16
=TB/29.7 / WETA-P25-12
=TB/29.7 / WETA-P25-11
generator
bearing temperature A
=TB/29.7 / WETA-P25-10
=TB/29.7 / WETA-P25-9
=TB/29.7 / WETA-P25-8
winding
temperature 3
=TB/29.6 / WETA-P25-7
=TB/29.7 / WETA-P25-15
=TB/29.7 / WETA-P25-14
winding
temperature 2
-11B4.1
26
bn
=TB/29.7 / WETA-P25-13
-11B4
bu
=TB/29.6 / WETA-P25-6
=TB/29.6 / WETA-P25-5
10
previous
REV
DESCRIPTION
17
-11B3.1
ye
=TB/29.6 / WETA-P25-4
=TB/29.6 / WETA-P25-3
=TB/29.6 / WETA-P25-2
=TB/29.6 / WETA-P25-1
winding
temperature 1
-11B2.1
-22AWG
Li12YC11Y-HF(TP)
4x2x
X7
-22AWG
Li12YC11Y-HF(TP)
4x2x
REV
Sh
of
11
11
Cover Page
GE Wind Energy 1.6MW
WTG Drw No.:
WTG No.:
Project/CMS No.:
Customer:
Component:
Comp No.:
Comp-Drw. No.:
Comp-Part No.:
Frequency:
Rated Voltage:
Control Voltage:
108W6614
16111805 - 813
Aratua-1 / 712835
BioEnergy
Slipring
104W5916
104W5966P001
50/60 Hz
690V / 400V
230V / 24VDC
2
DATE
=GE/11
previous
REV
DESCRIPTION
CHECKED BY
REVISED BY
06-APR-2009 06-APR-2009
R. Shaw
J. Curtis
GE Energy
DRAWN
ISSUED
25-APR-2008 G.Stultz
DWB
SIGNATURE
ENGINEER
12-SEPT-2007 T. Klodowski
DRAWN
25-APR-2008 G.Stultz
CHECKED
25-APR-2008
ISSUED
next
GE Energy
Slipring
A. Ridenour
DWB
COMPONENT
TYPE
1.6 xle
Slipring
COMP NO.
= SR
+
COMP-DRW. NO.
104W5916
COMP-PART NO.
104W5966P001
REV
Sh
of
1
5
date
revision
change
page
04/25/08
Updated connections
09/11/08
04/06/09
Updated Border
Revised connections
30,31
1
previous
REV
DESCRIPTION
actual state
3
CHECKED BY
REVISED BY
06-APR-2009 06-APR-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
Slipring Modification
information
COMPONENT
TYPE
1.6 xle
Slipring
COMP NO.
COMP-DRW. NO.
104W5916
COMP-PART NO.
104W5966P001
REV
next
= SR
+
Sh
of
2
5
Hauptstromkreise/Main circuits
Wechselspannung/AC voltage
Gleichspannung/DC voltage
schwarz/black
schwarz/black
1,5mm
1,5mm
Neutralleiter/Neutral conductors
hellblau/light blue
1,5mm
Steuerstromkreise/Control circuit
Wechselspannung/AC voltage
Gleichspannung/DC voltage
rot/red
dunkelblau/dark blue
0,75mm
0,75mm
orange
1,5mm
Ortskennzeichnung
Kabel-Nr.
Bezeichnung
Plant
designation
Positiondesignation
Cable-No.
Designation
=SR
32
Schleifringbertrager
slip ring transformer
ST
Stator
RT
Rotor
(Mindestquerschnitt !)
(Min. cross section !)
terminals
voltage
-X1
-X2
-X3
-X4
-X5
-X6
-X7
-X8
-X9
-X10
W1230.##
Kabelverbindung vom Schleifringbertrager zum Leitschrank/Cable connection from Slipring transformer to the Control cabinet ->
2
previous
REV
DESCRIPTION
CHECKED BY
REVISED BY
06-APR-2009 06-APR-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
W3260.##
COMPONENT
COMP-DRW. NO.
104W5916
COMP-PART NO.
104W5966P001
REV
next
= SR
+
1.6 xle
Slipring
COMP NO.
TYPE
Sh
of
3
5
3
previous
REV
DESCRIPTION
A
Updated Border, Revised Connections
CHECKED BY
690V / 30A
REVISED BY
06-APR-2009 06-APR-2009
J. Curtis
R. Shaw
GE Energy
GENERAL ELECTRIC COMPANY
WIND ENERGY TECHNOLOGY
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
400V / 16A
230V / 20A
1L1
1L2
1L3
1N
1PE
2L1
2N
3L1
3N
2PE
5
PE
1L1
1L2
1L3
1N
1PE
2L1
2N
3L1
3N
2PE
5
24V / 10A
Slipring transformer
supply pitch 400V/230V
COMPONENT
Slipring
COMP NO.
1x14 AWG
PE
7x 16AWG
24V / 5A
COMP-DRW. NO.
104W5916
COMP-PART NO.
104W5966P001
=PCS+PS/6.7 / SR-12
1x14 AWG
GND
30SKO.1
=TB/17.4
30BBR3.1 / =TB/17.1
30MCA3.1 / =TB/17.5
30MCA2.1 / =TB/17.5
30MCA1.1 / =TB/17.2
Safety-Loop to hub
=PCS+PS/6.7 / SR-11
1x14 AWG
=PCS+PS/6.7 / SR-10
1x14 AWG
=PCS+PS/6.7 / SR-9
1x14 AWG
30SKI.1 / =TB/17.3
0VDC hub
+24VDC hub
=PCS+PS/6.7 / SR-8
1x14 AWG
30L-24.1 / =TB/29.4
30L+24.1 / =TB/29.4
=PCS+PS/6.7 / SR-7
3x14 AWG
1x14 AWG
30OUTBPE / =TB/11.8
* GND
Do Not
Connect
=PCS+PS/6.7 / SR-6
1x14 AWG
1x10 AWG
30BelN / =TB/11.8
*)
lighting
120/230V hub
*)
socket
120/230V hub
400V 1PE
400V 1N
400V 1L3
=PCS+PS/6.6 / SR-5
/ 322PE
=PCS+PS/6.5 / SR-4
1x10 AWG
30BelL1 / =TB/11.7
30OutN / =TB/11.6
30OutL1 / =TB/11.6
30HPE.4.1 / =TB/7.5
30HN.4.1 / =TB/7.5
30HL3.4.1 / =TB/7.4
400V 1L2
400V 1L1
690V PE
*) even
if main switch
is disabled
energized
1x10 AWG
L3
=PCS+PS/6.5 / SR-3
L2
=PCS+PS/6.4 / SR-2
L1
1x10 AWG
-RT
1x10 AWG
L3
30HL2.4.1 / =TB/7.4
30HL1.4.1 / =TB/7.3
690V PE / =TB/3.2
690V L3
690V L2
690V L1
=PCS+PS/6.4 / SR-1
L2
1x14 AWG
L1
=PCS+PS/5.1 / SR-1PE
-ST
1
5x14 AWG
1x14 AWG
GND
=PCS+PS/5.1 / SR-1N
1x14 AWG
+RT
2
=PCS+PS/5.0 / SR-1L3
+ST
1
1x14 AWG
1x14 AWG
1x8 AWG
690V L3 / =TB/3.2
690V L2 / =TB/3.1
690V L1 / =TB/3.1
=PCS+PS/5.0 / SR-1L2
=PCS+PS/5.0 / SR-1L1
=PCS+PS/4.1 / SR-PE
rotor
1x8 AWG
stator
=PCS+PS/4.0 / SR-L3
5x10AWG
1x8 AWG
1x8 AWG
* 4
Do Not
Connect
=PCS+PS/4.1 / SR-L2
=PCS+PS/4.1 / SR-L1
0
8
9
top - box
2
3
2
5
6
1
4
6
7
8
9
10
11
12
6
7
8
9
10
11
12
24V
10A
TYPE
1.6 xle
REV
= SR
+
A
of
Sh
next
4
5
5
Ethernet
RS-485
2P+1C
22AWG
WH/OR
OR/WH
BL/WH
SH
14
15
16
13
8 7 6 5 4 3 2 1
3x 16AWG
PE
22o
22u
4PE
2x 20AWG
30.PT.Sh / =TB/29.4
30.PT1.2 / =TB/29.4
-ETH1
EIA/TIA-568A
CAT 5e
30.PT1.1 / =TB/29.4
CAT5e-Kabel
2x2x
24 AWG
30SRH.L1 / =TB/7.6
Sig
Pin
TX+
1
TX2
RX+
3
RX6
30FTH.SH
CONNECTOR KEY
Top - Box
30FTH
=TB/13.2
SPARE
PT 100
slipring
transformer
SRH.PE / =TB/7.7
SRH.N / =TB/7.7
heaters
slipring
transformer
WHT
BRN
23o
23u
+ST
stator
-ST
18
19
20
21
17
Sh
-PE
L1
24
PE
-31E1
PTC heater 2
slipring unit
-31B1
RTD
PT100
+RT
13
WH/OR
OR/WH
BL/WH
SH
CAT5-Kabel
2x2x
22 AWG
18
19
20
21
17
WH
YE
BU
OG
SH
SPARE
4
previous
REV
DESCRIPTION
/ SR-25
16
=PCS+PS/6.8 / SR-24
15
=PCS+PS/6.8 / SR-21
RS-485
2P+1C
22AWG
14
=PCS+PS/6.8 / SR-23
-RT
=PCS+PS/6.8 / SR-22
rotor
Ethernet
=PCS+Ax1/1
CHECKED BY
REVISED BY
06-APR-2009 06-APR-2009
J. Curtis
R. Shaw
GE Energy
DRAWN
25-APR-2008 G.Stultz
ISSUED
DWB
Slipring transformer
supply pitch
24V / signal
COMPONENT
TYPE
1.6 xle
Slipring
COMP NO.
COMP-DRW. NO.
104W5916
COMP-PART NO.
104W5966P001
REV
next
= SR
+
Sh
of
5
5
Cover Page
GE Wind Energy 1.6MW
WTG Drw No.:
WTG No.:
Project/CMS No.:
Customer:
Component:
Comp No.:
Comp-Drw. No.:
Comp-Part No.:
Frequency:
Rated Voltage:
Control Voltage:
108W6614
16111805 - 813
Aratua-1 / 712835
BioEnergy
104W4611
104W2609P001
50/60Hz
690V / 400V
230V / 24VDC
2
SIGNATURE
=SR+/5
previous
REV
DESCRIPTION
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
ISSUED
12-SEP-2007 A. Ridenour
See PLM
DATE
DRAWN
12-SEP-2007 A. Ridenour
CHECKED
12-SEP-2007 J. Melius
ENGINEER
12-SEP-2007 A. Ridenour
ISSUED
See PLM
COMPONENT
TYPE
next
GE Energy
= PCS
+ Ax1
Documentation
REV
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
Sh
of
1
10
date
revision
09/12/07
change
page
ECR
New Release
09/17/08
Updated Border
03/30/09
12/17/09
09-17-2010
5, 8
3000631
01-06-2011
+PS/5,+PS/8
3000631
1
previous
REV
DESCRIPTION
3
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Axis 1 Modification
Information
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax1
Sh
of
2
10
-F2
1
4.0
DC Link Pos
AEPA-J12-1
5 Amp, 600Vdc
Time Delay
4.0
K23 Coil A
AEPA-J13-12
A1
-K23
A2
1
2 .4
-K23
1
-D1
-D2
-D3
POS
4.0
A1
.4
A1
151X1225DF01PC01
1
1
3
DB+
Power
Supply
Coil
Driver
-DB
Enable
Digital In
24Vdc
Resistor
DB-
12
13
14
RS-485 -
Enable -
Enable +
6.4
Shield
6.3
6.1
AEPA-J6-6
6.1
AEPA-J6-5
4.0
AEPA-J13-8
4.0
AEPA-J12-4
4.0
AEPA-J12-2
10.7
HDP2-JA-1
10
+PS/4.1
A1-PEGND
11
Control Power
2
previous
REV
DESCRIPTION
+PS/4.8
A1-L1SW
+PS/4.8
A1-L2SW
+PS/4.8
A1-L3SW
10
-X3.A.1
AEPA-J4-2
RS-485 +
6.3
-D6
Communication
to AEPA
AEPA-J4-1
Torque Ref. -
-T1A
6.2
AEPA-J6-16
-T1B
Torque Ref +
6.2
-T1C
-J5
AEPA-J6-15
T2
NEG
Enable Acknowledge +
60A,
600VAC
6.1
AEPA-J6-7
60A,
600VAC
T2
-F1A
Enable Acknowledge -
-F1B
1
4.0
6.1
60A,
600VAC
AEPA-J6-8
-F1C
-C1
4
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Axis Box 1
Power Connections
to Converter
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax1
Sh
of
3
10
HDP1-JA-1
-K21
10.0
-K22
Converter Contactor
3.9
A1
D4-1 / 5.0
10.7
HDP2-JA-2
10.1
HDP1-JA-2
3.9
T2
MTR-A1 / 5.0
NC Aux
7
NC Aux
7
NO Aux
8
External
Devices
NO Aux
8
-S1
Coil
A
1
3
5
6
-F3
5A, 600Vdc
Time Delay
Coil
B
2
4
8
7
A
.3
.3
.3
.3
1
3
5
6
B
2
4
8
7
.4
.4
.4
.4
90 Limit
Switch
21
22
13
14
-S2
0 Limit
Switch
21
22
13
14
3.9
AEPA-J13-12
3.6
AEPA-J13-8
3.4
AEPA-J12-4
3.4
5.0
AEPA-J12-2
MCB-4
3.9
5.0
AEPA-J12-1
MCB-12
-AEPA -J12
48Vdc Batt
-J13
10
11
12
-J7
90deg LS
Digital In
24Vdc
Analog Inputs
Voltage Range: 48 - 90 Vdc
0deg LS
Digital In
24Vdc
10
11
12
13
14
15
16
17
18
19
20
BWI
Digital In
24Vdc
-K3
-K1 -K2
-K6
P24 In
Coil
Driver
-K5
Note: All internal card connections are for
indication only. Please refer to the card
schematic for the most up-to-date drawings.
PCOM
DC Link +
PCOM
3
previous
REV
DESCRIPTION
5
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Axis Box 1
Contactors and
Limit Switches
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax1
Sh
of
4
10
S1
S1
-D4
-D5
2
S2
4.9
D4-1
Series Field
-Motor Assembly
1
A2
3
4.9
MTR-A1
M
1~
S2
A1
230VAC
-RTD
30W
Heater
-MCB
10
11
12
13
14
15
16
-IE
PhiAnot
Znot
Power
PhiB
PhiA
COM
Brake
PhiBnot
-BWI
10
7.5
X6.A.1-1
7.5
4.9
AEPA-J16-3
MCB-4
4.9
MCB-12
-AEPA
-J11
-J8
Motor RTD
Analog In
<24Vdc
-J10
Brake Drive
(Uses PWM
chopper)
7.3
Htr_Neut
7.3
4
previous
REV
DESCRIPTION
Htr_Pwr
-K3
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Axis Box 1
Motor Connections
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax1
Sh
of
5
10
-AEPA
-J9
Shield
Clock-
Clock+
Data-
Data+
Thermistor -
PCOM
HDP2-JC-10
10.9
HDP1-JC-10
Thermistor -
10.4
HDP2-JC-9
Thermistor +
10.9
Thermistor +
-J5
10.4
12
HDP1-JC-9
11
24Vdc Out
10
GND
Battery Box
Thermistor
Analog In
24Vdc
10.2
HDP1-JB-4
24Vdc In
10.1
P24 In
Jumper
HDP1-JC-8
10.4
10.4
No
Connection
HDP1-JC-7
HDP1-JC-3
HDP1-JC-2
HDP1-JC-1
HDP1-JC-11
HDP1-JC-4
10.4
Connector ID Out
10.3
Connector ID In
10.3
-J3
10.3
PCOM
10.5
RS-485 -
HDP1-JC-13
RS-485 Shield
10.5
RS-485 Shield
Shield
RS-485 +
3.8
AEPA-J4-2
RS-485 -
3.8
3.7
AEPA-J6-16
AEPA-J4-1
RS-485 +
Batt. Lockout
Switch
Digital In
24Vdc
Jumper
Conn. ID
Digital In
24Vdc
HDP1-JC-12
-J4
16
Torque Ref -
Torque Ref +
15
3.7
14
3.7
13
P24 Supply
Communication
to Power
Converter
10.5
Torque Ref.
Analog Out
4-20 mA
AEPA-J6-15
Battery Neg
12
HDP2-JB-7
Battery +24Vdc
11
10.7
10
10.7
Enable Acknowledge -
AEPA-J6-8
Enable Acknowledge +
3.6
AEPA-J6-7
Enable -
3.7
AEPA-J6-6
5
previous
REV
DESCRIPTION
Enable Ack.
Digital In
12Vdc
3.6
Enable +
AEPA-J6-5
HDP2-JC-4
10.8
HDP2-JC-3
HDP2-JC-2
Connector ID In
10.8
10.8
HDP2-JC-1
Connector ID Out
10.8
-J6
3.6
Conn. ID
Digital In
24Vdc
Power for
Maintenance
Mode
Operation
HDP2-JB-1
Batt. Lockout
Switch
Enable
Digital In
Digital Out
24Vdc
24Vdc
HDP1-JB-10
Communication
to Battery
Charger
Power
7
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax1
Sh
of
6
10
-AEPA
-J15
1
5.5 / Htr_Neut
-K8
-K9
3
N
-BPPB
Communication Card
-K10
-Heater
750W
-FAN
230VAC
6
7
5.4 / Htr_Pwr
-J4
-J3
RJ45
RJ45
-J16
1
2
3
-K11
-J14
Blade ID
Digital In
24Vdc
-FAN1
-FAN2
230VAC
230VAC
Surge Aux
PCOM
Safety Loop
Mains Contactor ON
Single-Ended
Digital Inputs
24VDC
P24
P24SW
Deadman
Switch
Digital In
24Vdc
24Vdc for
Heater
Circuit
Auto/Man
Switch
Digital In
24Vdc
10.1
Thermistor
Analog In
24Vdc
PCOM
HDP1-JB-3
10.2
-J1
10
11
12
13
14
15
16
17
18
-J2
-PE-GND-
HDP1-JB-9
10.3
10
12
14
16
18
20
+PS/8.5
A1-X6.A.1-20
+PS/8.5
A1-X6.A.1-18
-X6.A.1
+PS/8.1
19
A1-X6.A.1-16
17
+PS/8.1
15
A1-X6.A.1-14
13
+PS/5.7
11
A1-SupplyNeut
+PS/5.7
A1-SupplyPwr
+PS/5.8
A1-HtrNeut
+PS/5.9
-X6.A.1
A1-HtrPwr
X6.A.1-1
AEPA-J16-3
10.2
HDP1-JB-8
10.1
HDP1-JB-12
HDP1-JB-2
Thermistor A1-AEPA-J2-2
+PS/8.0
+PS/8.0
A1-AEPA-J2-1
24Vdc Switched
+PS/7.3
+PS/7.3
A1-AEPA-J1-17
Deadman Switch -
Deadman Switch +
+PS/7.2
A1-AEPA-J1-14
+PS/7.2
A1-AEPA-J1-13
+PS/7.2
A1-AEPA-J1-12
+PS/7.2
A1-AEPA-J1-11
Surge Aux
No Connection
+PS/7.2
A1-AEPA-J1-10
+PS/7.2
A1-AEPA-J1-9
+PS/7.1
A1-AEPA-J1-8
+PS/7.1
+PS/7.1
A1-AEPA-J1-7
Mains Contactor On
A1-AEPA-J1-6
+PS/7.1
A1-AEPA-J1-5
ID Input 1
ID Input 0
24V Return
24Vdc
6
previous
REV
DESCRIPTION
+PS/7.1
A1-AEPA-J1-4
+PS/7.1
A1-AEPA-J1-3
+PS/7.1
A1-AEPA-J1-2
+PS/7.0
+PS/7.0
A1-AEPA-J1-1
A1-ENET
+PS/8.9
10.2
HDP1-JB-6
8
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax1
Sh
of
7
10
-B1
-B2
16Ah
Lead-Acid Battery
16Ah
Lead-Acid Battery
9.0
Battery +24Vdc
9.0
WPBCB3-PL3-1
9.0
WPBCB3-PL3-3
-PL3
-PL1
-PL3
-F1
80 Amp,
125Vdc
Forklift
Truck
Fuse
-PL2
-PL1
-WPBCB1
-WPBCB2
Battery Charger
12
13
P5
P12
Battery Charger
P5
P12
10
11
12
13
14
-PL2
15
10
11
14
15
-F2
5 Amp,
600Vdc
Time-Delay
9.0
WPBCB3-PL2-14
9.0
WPBCB3-PL2-6
9.0
WPBCB3-PL2-7
1
11
23
33
41
12
24
34
42
-Q1
DC
Disconnect
Switch
10kOhm
Thermistor
Lighting
-FAN
Heater Neutral
Heater Power
10.2
10.1
750W
Heater
HDC1-JB-2
Light Neutral
10.3
HDC1-JB-12
10.2
HDC1-JB-6
10.4
Light Power
Thermistor HDC1-JC-10
10.4
HDC1-JC-9
10.2
24Vdc Out
HDC1-JB-10
24Vdc In
10.1
HDC1-JB-4
10.3
Thermistor +
230Vac
9
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Battery Box 1
COMPONENT
TYPE
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax1
Documentation
COMP-DRW. NO.
HDC1-JB-8
Connector ID Out
HDC1-JC-2
Connector ID In
10.3
HDC1-JC-1
10.5
RS-485 Shield
10.5
HDC1-JC-13
RS-485 +
10.5
HDC1-JC-11
HDC1-JC-12
RS-485 -
Supply Power
10.1
HDC1-JB-3
HDC1-JB-9
10.4
10.2
Supply Neutral
10.4
10.1
10.4
7
previous
REV
DESCRIPTION
HDC1-JB-1
Battery +24Vdc
10.3
HDC1-JC-3
10.0
HDC1-JA-1
L1
Sh
of
8
10
8.9
-B3
-B4
16Ah
Lead-Acid Battery
16Ah
Lead-Acid Battery
Battery +24Vdc
-PL1
-PL1
12
13
8.9
WPBCB3-PL3-3
8.9
WPBCB3-PL3-1
-PL3
-PL3
-WPBCB3
-WPBCB4
Battery Charger
P5
P12
Battery Charger
P5
-PL2
P12
10
11
12
13
14
15
-PL2
10
11
14
15
8.9
WPBCB3-PL2-14
8.9
WPBCB3-PL2-6
8.9
8
previous
REV
DESCRIPTION
10.2
Battery Neg
HDC1-JB-7
10.1
HDC1-JA-2
Battery Neg
WPBCB3-PL2-7
10
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Battery Box 1
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax1
Sh
of
9
10
C
8.0
See PLM
REVISED BY
8.6
HDC1-JB-9
8.3
HDC1-JB-8
8.9
HDC1-JB-7
9.8
HDC1-JB-6
8.8
HDC1-JB-4
8.6
HDC1-JB-3
8.3
HDC1-JB-2
8.8
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
GENERAL ELECTRIC COMPANY
WIND ENERGY TECHNOLOGY
C
HDC1-JC-13
8.5
HDC1-JC-12
8.4
HDC1-JC-11
8.4
HDC1-JC-10
8.7
HDC1-JC-9
8.7
HDC1-JC-8
8.2
NC
NC
NC
JC-15
JC-16-25
RS-485 Shield
RS-485 +
RS-485 -
Thermistor -
Thermistor +
JB-3
JB-4
JB-5
JB-6
JB-7
JB-8
JB-9
JB-10
JB-11
JB-12
Supply Power
24Vdc In
NC
Light Power
NC
Battery Box Heater Neutral
Supply Neutral
24Vdc Out
NC
Light Neutral
JC-2
JC-3
JC-4
JC-5
JC-6
JC-7
JC-8
JC-9
JC-10
JC-11
JC-12
JC-13
JC-14
JC-15
JC-16-25
Connector ID Out
Battery Lockout Switch +
Battery Lockout Switch -
NC
NC
Battery Main. Switch +
Battery Main. Switch -
Thermistor +
Thermistor RS-485 RS-485 +
RS-485 Shield
NC
NC
NC
Battery Box 1
Axis-to-Battery Connector
JA-2
Battery Neg
COMP NO.
JB-2-6
NC
COMPONENT
COMP-PART NO.
104W2609P001
REV
TYPE
Documentation
HDP2-JC-10
6.7
HDP2-JC-9
Maintenance Mode
JC-11-25
JC-10
Thermistor -
6.7
HDP2-JC-4
6.1
HDP2-JC-3
6.1
HDP2-JC-2
6.0
HDP2-JC-1
6.0
NC
JC-9
Thermistor +
JC-4
Battery Lockout Switch -
JC-5-8
JC-3
Battery Lockout Switch +
NC
JC-2
JC-1
HDP2-JB-7
6.2
HDP2-JB-1
6.2
Connector ID Out
Connector ID In
JB-7
Battery Neg
8-12
JB-1
Operation Mode
Battery +24V
HDP2-JA-2
4.0
HDP2-JA-1
3.3
JA-1
Battery Pos
HDP1-JC-13
6.4
HDP1-JC-12
6.3
HDP1-JC-11
6.4
HDP1-JC-10
6.7
HDP1-JC-9
6.7
HDP1-JC-8
6.6
HDP1-JC-7
6.5
HDP1-JC-4
6.5
HDP1-JC-3
6.5
HDP1-JC-2
6.5
HDP1-JC-1
6.5
Heavy-Duty Plug 2
JC-1
Connector ID In
HDP1-JB-12
7.9
HDP1-JB-10
6.6
HDP1-JB-9
7.9
HDP1-JB-8
7.5
HDP1-JB-6
7.9
HDP1-JB-4
6.6
HDP1-JB-3
7.9
HDP1-JB-2
7.5
JC-14
JC-13
JC-12
JC-11
JC-10
JC-9
JC-7
JC-8
NC
NC
Connector ID Out
JC-6
JC-5
JC-4
JC-3
JC-2
Connector ID In
JB-2
JB-1
NC
HDP1-JA-2
4.0
HDP1-JA-1
4.0
HDC1-JC-7
8.1
HDC1-JC-4
8.2
HDC1-JC-3
8.1
HDC1-JC-2
8.5
JC-1
Light Neutral
JB-12
JA-2
Battery Neg
JA-1
Battery Pos
HDC1-JC-1
8.5
HDC1-JB-12
NC
24Vdc Out
Supply Neutral
Heater Neutral
JB-11
JB-10
JB-9
JB-8
Battery Neg
Light Power
JB-6
JB-7
NC
24Vdc In
Supply Power
Heater Power
Battery +24Vdc
Battery Neg
Battery Pos
JB-5
JB-4
JB-3
JB-2
JB-1
JA-2
JA-1
Heavy-Duty Plug 1
HDC1-JB-10
9
previous
REV
DESCRIPTION
8.9
HDC1-JB-1
8.1
HDC1-JA-2
9.8
HDC1-JA-1
Heavy-Duty Connector 1
0
9
+Ax2/1
= PCS
+ Ax1
of
Sh
next
10
10
Cover Page
GE Wind Energy 1.6MW
WTG Drw No.:
WTG No.:
Project/CMS No.:
Customer:
Component:
Comp No.:
Comp-Drw. No.:
Comp-Part No.:
Frequency:
Rated Voltage:
Control Voltage:
108W6614
16111805 - 813
Aratua-1 / 712835
BioEnergy
104W4611
104W2609P001
50/60Hz
690V / 400V
230V / 24VDC
2
SIGNATURE
+Ax1/10
previous
REV
DESCRIPTION
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
ISSUED
12-SEP-2007 A. Ridenour
See PLM
DATE
DRAWN
12-SEP-2007 A. Ridenour
CHECKED
12-SEP-2007 J. Melius
ENGINEER
12-SEP-2007 A. Ridenour
ISSUED
See PLM
COMPONENT
TYPE
next
GE Energy
= PCS
+ Ax2
Documentation
REV
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
Sh
of
1
10
date
09/12/07
revision
change
page
ECR
New Release
09/17/08
Updated Border
03/30/09
12/17/09
09-17-2010
5, 8
3000631
01-06-2011
+PS/5,+PS/8
3000631
01-06
1
previous
REV
DESCRIPTION
3
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Axis 2 Modification
Information
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax2
Sh
of
2
10
-F2
1
4.0
DC Link Pos
AEPA-J12-1
5 Amp, 600Vdc
Time Delay
4.0
K23 Coil A
AEPA-J13-12
A1
-K23
A2
1
2 .4
-K23
1
-D1
-D2
-D3
POS
4.0
A1
.4
A1
151X1225DF01PC01
1
1
3
DB+
Power
Supply
Coil
Driver
-DB
Enable
Digital In
24Vdc
Resistor
DB-
12
13
14
RS-485 -
Enable -
Enable +
6.4
Shield
6.3
6.1
AEPA-J6-6
6.1
AEPA-J6-5
4.0
AEPA-J13-8
4.0
AEPA-J12-4
4.0
AEPA-J12-2
10.7
HDP2-JA-1
10
+PS/4.2
A2-PEGND
11
Control Power
2
previous
REV
DESCRIPTION
+PS/4.9
A2-L1SW
+PS/4.9
A2-L2SW
+PS/4.9
A2-L3SW
10
-X3.A.1
AEPA-J4-2
RS-485 +
6.3
-D6
Communication
to AEPA
AEPA-J4-1
Torque Ref. -
-T1A
6.2
AEPA-J6-16
-T1B
Torque Ref +
6.2
-T1C
-J5
AEPA-J6-15
T2
NEG
Enable Acknowledge +
60A,
600VAC
6.1
AEPA-J6-7
60A,
600VAC
T2
-F1A
Enable Acknowledge -
-F1B
1
4.0
6.1
60A,
600VAC
AEPA-J6-8
-F1C
-C1
4
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Axis Box 2
Power Connections
to Converter
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax2
Sh
of
3
10
HDP1-JA-1
-K21
10.0
-K22
Converter Contactor
3.9
A1
D4-1 / 5.0
10.7
HDP2-JA-2
10.1
HDP1-JA-2
3.9
T2
MTR-A1 / 5.0
NC Aux
7
NC Aux
7
NO Aux
8
External
Devices
NO Aux
8
-S1
Coil
A
1
3
5
6
-F3
5A, 600Vdc
Time Delay
Coil
B
2
4
8
7
A
.3
.3
.3
.3
1
3
5
6
B
2
4
8
7
.4
.4
.4
.4
90 Limit
Switch
21
22
13
14
-S2
0 Limit
Switch
21
22
13
14
3.9
AEPA-J13-12
3.6
AEPA-J13-8
3.4
AEPA-J12-4
3.4
5.0
AEPA-J12-2
MCB-4
3.9
5.0
AEPA-J12-1
MCB-12
-AEPA -J12
48Vdc Batt
-J13
10
11
12
-J7
90deg LS
Digital In
24Vdc
Analog Inputs
Voltage Range: 48 - 90 Vdc
0deg LS
Digital In
24Vdc
10
11
12
13
14
15
16
17
18
19
20
BWI
Digital In
24Vdc
-K3
-K1 -K2
-K6
P24 In
Coil
Driver
-K5
Note: All internal card connections are for
indication only. Please refer to the card
schematic for the most up-to-date drawings.
PCOM
DC Link +
PCOM
3
previous
REV
DESCRIPTION
5
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Axis Box 2
Contactors and
Limit Switches
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax2
Sh
of
4
10
S1
S1
-D4
-D5
2
S2
4.9
D4-1
Series Field
-Motor Assembly
1
A2
3
4.9
MTR-A1
M
1~
S2
A1
230VAC
-RTD
30W
Heater
-MCB
10
11
12
13
14
15
16
-IE
PhiAnot
Znot
Power
PhiB
PhiA
COM
Brake
PhiBnot
-BWI
10
7.5
X6.A.1-1
7.5
4.9
AEPA-J16-3
MCB-4
4.9
MCB-12
-AEPA
-J11
-J8
Motor RTD
Analog In
<24Vdc
-J10
Brake Drive
(Uses PWM
chopper)
7.3
Htr_Neut
7.3
4
previous
REV
DESCRIPTION
Htr_Pwr
-K3
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Axis Box 2
Motor Connections
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax2
Sh
of
5
10
-AEPA
-J9
Shield
Clock-
Clock+
Data-
Data+
Thermistor -
PCOM
HDP2-JC-10
10.9
HDP1-JC-10
Thermistor -
10.4
HDP2-JC-9
Thermistor +
10.9
Thermistor +
-J5
10.4
12
HDP1-JC-9
11
24Vdc Out
10
GND
Battery Box
Thermistor
Analog In
24Vdc
10.2
HDP1-JB-4
24Vdc In
10.1
P24 In
Jumper
HDP1-JC-8
10.4
10.4
No
Connection
HDP1-JC-7
HDP1-JC-3
HDP1-JC-2
HDP1-JC-1
HDP1-JC-11
HDP1-JC-4
10.4
Connector ID Out
10.3
Connector ID In
10.3
-J3
10.3
PCOM
10.5
RS-485 -
HDP1-JC-13
RS-485 Shield
10.5
RS-485 Shield
Shield
RS-485 +
3.8
AEPA-J4-2
RS-485 -
3.8
3.7
AEPA-J6-16
AEPA-J4-1
RS-485 +
Batt. Lockout
Switch
Digital In
24Vdc
Jumper
Conn. ID
Digital In
24Vdc
HDP1-JC-12
-J4
16
Torque Ref -
Torque Ref +
15
3.7
14
3.7
13
P24 Supply
Communication
to Power
Converter
10.5
Torque Ref.
Analog Out
4-20 mA
AEPA-J6-15
Battery Neg
12
HDP2-JB-7
Battery +24Vdc
11
10.7
10
10.7
Enable Acknowledge -
AEPA-J6-8
Enable Acknowledge +
3.6
AEPA-J6-7
Enable -
3.7
AEPA-J6-6
5
previous
REV
DESCRIPTION
Enable Ack.
Digital In
12Vdc
3.6
Enable +
AEPA-J6-5
HDP2-JC-4
10.8
HDP2-JC-3
HDP2-JC-2
Connector ID In
10.8
10.8
HDP2-JC-1
Connector ID Out
10.8
-J6
3.6
Conn. ID
Digital In
24Vdc
Power for
Maintenance
Mode
Operation
HDP2-JB-1
Batt. Lockout
Switch
Enable
Digital In
Digital Out
24Vdc
24Vdc
HDP1-JB-10
Communication
to Battery
Charger
Power
7
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax2
Sh
of
6
10
-AEPA
-J15
1
5.5 / Htr_Neut
-K8
-K9
3
N
-BPPB
Communication Card
-K10
-Heater
750W
-FAN
230VAC
6
7
5.4 / Htr_Pwr
-J4
-J3
RJ45
RJ45
-J16
1
2
3
-K11
-J14
Blade ID
Digital In
24Vdc
-FAN1
-FAN2
230VAC
230VAC
Surge Aux
PCOM
Safety Loop
Mains Contactor ON
Single-Ended
Digital Inputs
24VDC
P24
P24SW
Deadman
Switch
Digital In
24Vdc
24Vdc for
Heater
Circuit
Auto/Man
Switch
Digital In
24Vdc
10.1
Thermistor
Analog In
24Vdc
PCOM
HDP1-JB-3
10.2
-J1
10
11
12
13
14
15
16
17
18
-J2
-PE-GND-
HDP1-JB-9
10.3
-X6.A.1
10
12
14
16
18
20
+PS/8.2
19
A2-X6.A.1-16
17
+PS/8.2
15
A2-X6.A.1-14
13
+PS/5.7
11
A2-SupplyNeut
+PS/5.8
A2-SupplyPwr
+PS/5.8
A2-HtrNeut
+PS/5.9
-X6.A.1
A2-HtrPwr
X6.A.1-1
AEPA-J16-3
10.2
HDP1-JB-8
10.1
HDP1-JB-12
HDP1-JB-2
Thermistor A2-AEPA-J2-2
+PS/8.4
+PS/8.3
A2-AEPA-J2-1
No Connection
No Connection
A2-AEPA-J1-18
+PS/7.6
+PS/7.6
A2-AEPA-J1-17
Deadman Switch -
Deadman Switch +
+PS/7.5
A2-AEPA-J1-14
+PS/7.5
A2-AEPA-J1-13
+PS/7.5
A2-AEPA-J1-12
+PS/7.5
A2-AEPA-J1-11
Surge Aux
No Connection
+PS/7.5
A2-AEPA-J1-10
+PS/7.5
A2-AEPA-J1-9
+PS/7.5
A2-AEPA-J1-8
+PS/7.4
+PS/7.4
A2-AEPA-J1-7
Mains Contactor On
A2-AEPA-J1-6
+PS/7.4
A2-AEPA-J1-5
ID Input 1
ID Input 0
24V Return
24Vdc
6
previous
REV
DESCRIPTION
+PS/7.4
A2-AEPA-J1-4
+PS/7.4
A2-AEPA-J1-3
+PS/7.4
A2-AEPA-J1-2
+PS/7.3
+PS/7.3
A2-AEPA-J1-1
A2-ENET
+PS/8.9
10.2
HDP1-JB-6
8
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax2
Sh
of
7
10
-B1
-B2
16Ah
Lead-Acid Battery
16Ah
Lead-Acid Battery
9.0
Battery +24Vdc
9.0
WPBCB3-PL3-1
9.0
WPBCB3-PL3-3
-PL3
-PL1
-PL3
-F1
80 Amp,
125Vdc
Forklift
Truck
Fuse
-PL2
-PL1
-WPBCB1
-WPBCB2
Battery Charger
12
13
P5
P12
Battery Charger
P5
P12
10
11
12
13
14
-PL2
15
10
11
14
15
-F2
5 Amp,
600Vdc
Time-Delay
9.0
WPBCB3-PL2-14
9.0
WPBCB3-PL2-6
9.0
WPBCB3-PL2-7
1
11
23
33
41
12
24
34
42
-Q1
DC
Disconnect
Switch
10kOhm
Thermistor
Lighting
-FAN
Heater Neutral
Heater Power
10.2
10.1
750W
Heater
HDC1-JB-2
Light Neutral
10.3
HDC1-JB-12
10.2
HDC1-JB-6
10.4
Light Power
Thermistor HDC1-JC-10
10.4
HDC1-JC-9
10.2
24Vdc Out
HDC1-JB-10
24Vdc In
10.1
HDC1-JB-4
10.3
Thermistor +
230Vac
9
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Battery Box 2
COMPONENT
TYPE
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax2
Documentation
COMP-DRW. NO.
HDC1-JB-8
Connector ID Out
HDC1-JC-2
Connector ID In
10.3
HDC1-JC-1
10.5
RS-485 Shield
10.5
HDC1-JC-13
RS-485 +
10.5
HDC1-JC-11
HDC1-JC-12
RS-485 -
Supply Power
10.1
HDC1-JB-3
HDC1-JB-9
10.4
10.2
Supply Neutral
10.4
10.1
10.4
7
previous
REV
DESCRIPTION
HDC1-JB-1
Battery +24Vdc
10.3
HDC1-JC-3
10.0
HDC1-JA-1
L1
Sh
of
8
10
8.9
-B3
-B4
16Ah
Lead-Acid Battery
16Ah
Lead-Acid Battery
Battery +24Vdc
-PL1
-PL1
12
13
8.9
WPBCB3-PL3-3
8.9
WPBCB3-PL3-1
-PL3
-PL3
-WPBCB3
-WPBCB4
Battery Charger
P5
P12
Battery Charger
P5
-PL2
P12
10
11
12
13
14
15
-PL2
10
11
14
15
8.9
WPBCB3-PL2-14
8.9
WPBCB3-PL2-6
8.9
8
previous
REV
DESCRIPTION
10.2
Battery Neg
HDC1-JB-7
10.1
HDC1-JA-2
Battery Neg
WPBCB3-PL2-7
10
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Battery Box 2
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax2
Sh
of
9
10
C
8.0
See PLM
REVISED BY
8.6
HDC1-JB-9
8.3
HDC1-JB-8
8.9
HDC1-JB-7
9.8
HDC1-JB-6
8.8
HDC1-JB-4
8.6
HDC1-JB-3
8.3
HDC1-JB-2
8.8
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
GENERAL ELECTRIC COMPANY
WIND ENERGY TECHNOLOGY
C
HDC1-JC-13
8.5
HDC1-JC-12
8.4
HDC1-JC-11
8.4
HDC1-JC-10
8.7
HDC1-JC-9
8.7
HDC1-JC-8
8.2
NC
NC
NC
JC-15
JC-16-25
RS-485 Shield
RS-485 +
RS-485 -
Thermistor -
Thermistor +
JB-3
JB-4
JB-5
JB-6
JB-7
JB-8
JB-9
JB-10
JB-11
JB-12
Supply Power
24Vdc In
NC
Light Power
NC
Battery Box Heater Neutral
Supply Neutral
24Vdc Out
NC
Light Neutral
JC-2
JC-3
JC-4
JC-5
JC-6
JC-7
JC-8
JC-9
JC-10
JC-11
JC-12
JC-13
JC-14
JC-15
JC-16-25
Connector ID Out
Battery Lockout Switch +
Battery Lockout Switch -
NC
NC
Battery Main. Switch +
Battery Main. Switch -
Thermistor +
Thermistor RS-485 RS-485 +
RS-485 Shield
NC
NC
NC
Battery Box 2
Axis-to-Battery Connector
JA-2
Battery Neg
COMP NO.
JB-2-6
NC
COMPONENT
COMP-PART NO.
104W2609P001
REV
TYPE
Documentation
HDP2-JC-10
6.7
HDP2-JC-9
Maintenance Mode
JC-11-25
JC-10
Thermistor -
6.7
HDP2-JC-4
6.1
HDP2-JC-3
6.1
HDP2-JC-2
6.0
HDP2-JC-1
6.0
NC
JC-9
Thermistor +
JC-4
Battery Lockout Switch -
JC-5-8
JC-3
Battery Lockout Switch +
NC
JC-2
JC-1
HDP2-JB-7
6.2
HDP2-JB-1
6.2
Connector ID Out
Connector ID In
JB-7
Battery Neg
8-12
JB-1
Operation Mode
Battery +24V
HDP2-JA-2
4.0
HDP2-JA-1
3.3
JA-1
Battery Pos
HDP1-JC-13
6.4
HDP1-JC-12
6.3
HDP1-JC-11
6.4
HDP1-JC-10
6.7
HDP1-JC-9
6.7
HDP1-JC-8
6.6
HDP1-JC-7
6.5
HDP1-JC-4
6.5
HDP1-JC-3
6.5
HDP1-JC-2
6.5
HDP1-JC-1
6.5
Heavy-Duty Plug 2
JC-1
Connector ID In
HDP1-JB-12
7.9
HDP1-JB-10
6.6
HDP1-JB-9
7.9
HDP1-JB-8
7.5
HDP1-JB-6
7.9
HDP1-JB-4
6.6
HDP1-JB-3
7.9
HDP1-JB-2
7.5
JC-14
JC-13
JC-12
JC-11
JC-10
JC-9
JC-7
JC-8
NC
NC
Connector ID Out
JC-6
JC-5
JC-4
JC-3
JC-2
Connector ID In
JB-2
JB-1
NC
HDP1-JA-2
4.0
HDP1-JA-1
4.0
HDC1-JC-7
8.1
HDC1-JC-4
8.2
HDC1-JC-3
8.1
HDC1-JC-2
8.5
JC-1
Light Neutral
JB-12
JA-2
Battery Neg
JA-1
Battery Pos
HDC1-JC-1
8.5
HDC1-JB-12
NC
24Vdc Out
Supply Neutral
Heater Neutral
JB-11
JB-10
JB-9
JB-8
Battery Neg
Light Power
JB-6
JB-7
NC
24Vdc In
Supply Power
Heater Power
Battery +24Vdc
Battery Neg
Battery Pos
JB-5
JB-4
JB-3
JB-2
JB-1
JA-2
JA-1
Heavy-Duty Plug 1
HDC1-JB-10
9
previous
REV
DESCRIPTION
8.9
HDC1-JB-1
8.1
HDC1-JA-2
9.8
HDC1-JA-1
Heavy-Duty Connector 1
0
9
+Ax3/1
= PCS
+ Ax2
of
Sh
next
10
10
Cover Page
GE Wind Energy 1.6MW
WTG Drw No.:
WTG No.:
Project/CMS No.:
Customer:
Component:
Comp No.:
Comp-Drw. No.:
Comp-Part No.:
Frequency:
Rated Voltage:
Control Voltage:
108W6614
16111805 - 813
Aratua-1 / 712835
BioEnergy
104W4611
104W2609P001
50/60Hz
690V / 400V
230V / 24VDC
2
SIGNATURE
+Ax2/10
previous
REV
DESCRIPTION
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
ISSUED
12-SEP-2007 A. Ridenour
See PLM
DATE
DRAWN
12-SEP-2007 A. Ridenour
CHECKED
12-SEP-2007 J. Melius
ENGINEER
12-SEP-2007 A. Ridenour
ISSUED
See PLM
COMPONENT
TYPE
next
GE Energy
= PCS
+ Ax3
Documentation
REV
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
Sh
of
1
10
date
09/12/07
revision
change
page
ECR
New Release
09/17/08
Updated Border
03/30/09
09-17-2010
5, 8
3000631
01-06-2011
+PS/5,+PS/8
3000631
1
previous
REV
DESCRIPTION
3
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Axis 3 Modification
Information
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax3
Sh
of
2
10
-F2
1
4.0
DC Link Pos
AEPA-J12-1
5 Amp, 600Vdc
Time Delay
4.0
K23 Coil A
AEPA-J13-12
A1
-K23
A2
1
2 .4
-K23
1
-D1
-D2
-D3
POS
4.0
A1
.4
A1
151X1225DF01PC01
1
1
3
DB+
Power
Supply
Coil
Driver
-DB
Enable
Digital In
24Vdc
Resistor
DB-
12
13
14
RS-485 -
Enable -
Enable +
6.4
Shield
6.3
6.1
AEPA-J6-6
6.1
AEPA-J6-5
4.0
AEPA-J13-8
4.0
AEPA-J12-4
4.0
AEPA-J12-2
10.7
HDP2-JA-1
10
+PS/4.2
A3-PEGND
11
Control Power
2
previous
REV
DESCRIPTION
+PS/4.7
A3-L1SW
+PS/4.7
A3-L2SW
+PS/4.7
A3-L3SW
10
-X3.A.1
AEPA-J4-2
RS-485 +
6.3
-D6
Communication
to AEPA
AEPA-J4-1
Torque Ref. -
-T1A
6.2
AEPA-J6-16
-T1B
Torque Ref +
6.2
-T1C
-J5
AEPA-J6-15
T2
NEG
Enable Acknowledge +
60A,
600VAC
6.1
AEPA-J6-7
60A,
600VAC
T2
-F1A
Enable Acknowledge -
-F1B
1
4.0
6.1
60A,
600VAC
AEPA-J6-8
-F1C
-C1
4
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Axis Box 3
Power Connections
to Converter
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax3
Sh
of
3
10
HDP1-JA-1
-K21
10.0
-K22
Converter Contactor
3.9
A1
D4-1 / 5.0
10.7
HDP2-JA-2
10.1
HDP1-JA-2
3.9
T2
MTR-A1 / 5.0
NC Aux
7
NC Aux
7
NO Aux
8
External
Devices
NO Aux
8
-S1
Coil
A
1
3
5
6
-F3
5A, 600Vdc
Time Delay
Coil
B
2
4
8
7
A
.3
.3
.3
.3
1
3
5
6
B
2
4
8
7
.4
.4
.4
.4
90 Limit
Switch
21
22
13
14
-S2
0 Limit
Switch
21
22
13
14
3.9
AEPA-J13-12
3.6
AEPA-J13-8
3.4
AEPA-J12-4
3.4
5.0
AEPA-J12-2
MCB-4
3.9
5.0
AEPA-J12-1
MCB-12
-AEPA -J12
48Vdc Batt
-J13
10
11
12
-J7
90deg LS
Digital In
24Vdc
Analog Inputs
Voltage Range: 48 - 90 Vdc
0deg LS
Digital In
24Vdc
10
11
12
13
14
15
16
17
18
19
20
BWI
Digital In
24Vdc
-K3
-K1 -K2
-K6
P24 In
Coil
Driver
-K5
Note: All internal card connections are for
indication only. Please refer to the card
schematic for the most up-to-date drawings.
PCOM
DC Link +
PCOM
3
previous
REV
DESCRIPTION
5
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Axis Box 3
Contactors and
Limit Switches
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax3
Sh
of
4
10
S1
S1
-D4
-D5
2
S2
4.9
D4-1
Series Field
-Motor Assembly
1
A2
3
4.9
MTR-A1
M
1~
S2
A1
230VAC
-RTD
30W
Heater
-MCB
10
11
12
13
14
15
16
-IE
PhiAnot
Znot
Power
PhiB
PhiA
COM
Brake
PhiBnot
-BWI
10
7.5
X6.A.1-1
7.5
4.9
AEPA-J16-3
MCB-4
4.9
MCB-12
-AEPA
-J11
-J8
Motor RTD
Analog In
<24Vdc
-J10
Brake Drive
(Uses PWM
chopper)
7.3
Htr_Neut
7.3
4
previous
REV
DESCRIPTION
Htr_Pwr
-K3
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Axis Box 3
Motor Connections
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax3
Sh
of
5
10
-AEPA
-J9
Shield
Clock-
Clock+
Data-
Data+
Thermistor -
PCOM
HDP2-JC-10
10.9
HDP1-JC-10
Thermistor -
10.4
HDP2-JC-9
Thermistor +
10.9
Thermistor +
-J5
10.4
12
HDP1-JC-9
11
24Vdc Out
10
GND
Battery Box
Thermistor
Analog In
24Vdc
10.2
HDP1-JB-4
24Vdc In
10.1
P24 In
Jumper
HDP1-JC-8
10.4
10.4
No
Connection
HDP1-JC-7
HDP1-JC-3
HDP1-JC-2
HDP1-JC-1
HDP1-JC-11
HDP1-JC-4
10.4
Connector ID Out
10.3
Connector ID In
10.3
-J3
10.3
PCOM
10.5
RS-485 -
HDP1-JC-13
RS-485 Shield
10.5
RS-485 Shield
Shield
RS-485 +
3.8
AEPA-J4-2
RS-485 -
3.8
3.7
AEPA-J6-16
AEPA-J4-1
RS-485 +
Batt. Lockout
Switch
Digital In
24Vdc
Jumper
Conn. ID
Digital In
24Vdc
HDP1-JC-12
-J4
16
Torque Ref -
Torque Ref +
15
3.7
14
3.7
13
P24 Supply
Communication
to Power
Converter
10.5
Torque Ref.
Analog Out
4-20 mA
AEPA-J6-15
Battery Neg
12
HDP2-JB-7
Battery +24Vdc
11
10.7
10
10.7
Enable Acknowledge -
AEPA-J6-8
Enable Acknowledge +
3.6
AEPA-J6-7
Enable -
3.7
AEPA-J6-6
5
previous
REV
DESCRIPTION
Enable Ack.
Digital In
12Vdc
3.6
Enable +
AEPA-J6-5
HDP2-JC-4
10.8
HDP2-JC-3
HDP2-JC-2
Connector ID In
10.8
10.8
HDP2-JC-1
Connector ID Out
10.8
-J6
3.6
Conn. ID
Digital In
24Vdc
Power for
Maintenance
Mode
Operation
HDP2-JB-1
Batt. Lockout
Switch
Enable
Digital In
Digital Out
24Vdc
24Vdc
HDP1-JB-10
Communication
to Battery
Charger
Power
7
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax3
Sh
of
6
10
-AEPA
-J15
1
5.5 / Htr_Neut
-K8
-K9
3
N
-BPPB
Communication Card
-K10
-Heater
750W
-FAN
230VAC
6
7
5.4 / Htr_Pwr
-J4
-J3
RJ45
RJ45
-J16
1
2
3
-K11
-J14
Blade ID
Digital In
24Vdc
-FAN1
-FAN2
230VAC
230VAC
Surge Aux
PCOM
Safety Loop
Mains Contactor ON
Single-Ended
Digital Inputs
24VDC
P24
P24SW
Deadman
Switch
Digital In
24Vdc
24Vdc for
Heater
Circuit
Auto/Man
Switch
Digital In
24Vdc
PCOM
10.1
Thermistor
Analog In
24Vdc
HDP1-JB-3
10.2
-J1
10
11
12
13
14
15
16
17
18
-J2
-PE-GND-
HDP1-JB-9
10.3
-X6.A.1
10
12
14
16
18
20
+PS/8.3
19
A3-X6.A.1-16
17
+PS/8.2
15
A3-X6.A.1-14
13
+PS/5.6
11
A3-SupplyNeut
+PS/5.7
A3-SupplyPwr
+PS/5.8
A3-HtrNeut
+PS/5.9
-X6.A.1
A3-HtrPwr
X6.A.1-1
AEPA-J16-3
10.2
HDP1-JB-8
10.1
HDP1-JB-12
HDP1-JB-2
No Connection
A3-AEPA-J1-18
+PS/7.9
+PS/7.9
A3-AEPA-J1-17
Deadman Switch -
Deadman Switch +
+PS/7.8
A3-AEPA-J1-14
+PS/7.8
A3-AEPA-J1-13
+PS/7.8
A3-AEPA-J1-12
+PS/7.8
A3-AEPA-J1-11
Surge Aux
No Connection
+PS/7.8
A3-AEPA-J1-10
+PS/7.8
A3-AEPA-J1-9
+PS/7.8
A3-AEPA-J1-8
+PS/7.7
+PS/7.7
A3-AEPA-J1-7
Mains Contactor On
A3-AEPA-J1-6
+PS/7.7
A3-AEPA-J1-5
ID Input 1
ID Input 0
24V Return
24Vdc
6
previous
REV
DESCRIPTION
+PS/7.7
A3-AEPA-J1-4
+PS/7.7
A3-AEPA-J1-3
+PS/7.7
A3-AEPA-J1-2
+PS/7.7
+PS/7.6
A3-AEPA-J1-1
A3-ENET
+PS/8.9
10.2
HDP1-JB-6
8
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax3
Sh
of
7
10
-B1
-B2
16Ah
Lead-Acid Battery
16Ah
Lead-Acid Battery
9.0
Battery +24Vdc
9.0
WPBCB3-PL3-1
9.0
WPBCB3-PL3-3
-PL3
-PL1
-PL3
-F1
80 Amp,
125Vdc
Forklift
Truck
Fuse
-PL2
-PL1
-WPBCB1
-WPBCB2
Battery Charger
12
13
P5
P12
Battery Charger
P5
P12
10
11
12
13
14
-PL2
15
10
11
14
15
-F2
5 Amp,
600Vdc
Time-Delay
9.0
WPBCB3-PL2-14
9.0
WPBCB3-PL2-6
9.0
WPBCB3-PL2-7
1
11
23
33
41
12
24
34
42
-Q1
DC
Disconnect
Switch
10kOhm
Thermistor
Lighting
-FAN
Heater Neutral
Heater Power
10.2
10.1
750W
Heater
HDC1-JB-2
Light Neutral
10.3
HDC1-JB-12
10.2
HDC1-JB-6
10.4
Light Power
Thermistor HDC1-JC-10
10.4
HDC1-JC-9
10.2
24Vdc Out
HDC1-JB-10
24Vdc In
10.1
HDC1-JB-4
10.3
Thermistor +
230Vac
9
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Battery Box 3
COMPONENT
TYPE
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax3
Documentation
COMP-DRW. NO.
HDC1-JB-8
Connector ID Out
HDC1-JC-2
Connector ID In
10.3
HDC1-JC-1
10.5
RS-485 Shield
10.5
HDC1-JC-13
RS-485 +
10.5
HDC1-JC-11
HDC1-JC-12
RS-485 -
Supply Power
10.1
HDC1-JB-3
HDC1-JB-9
10.4
10.2
Supply Neutral
10.4
10.1
10.4
7
previous
REV
DESCRIPTION
HDC1-JB-1
Battery +24Vdc
10.3
HDC1-JC-3
10.0
HDC1-JA-1
L1
Sh
of
8
10
8.9
-B3
-B4
16Ah
Lead-Acid Battery
16Ah
Lead-Acid Battery
Battery +24Vdc
-PL1
-PL1
12
13
8.9
WPBCB3-PL3-3
8.9
WPBCB3-PL3-1
-PL3
-PL3
-WPBCB3
-WPBCB4
Battery Charger
P5
P12
Battery Charger
P5
-PL2
P12
10
11
12
13
14
15
-PL2
10
11
14
15
8.9
WPBCB3-PL2-14
8.9
WPBCB3-PL2-6
8.9
8
previous
REV
DESCRIPTION
10.2
Battery Neg
HDC1-JB-7
10.1
HDC1-JA-2
Battery Neg
WPBCB3-PL2-7
10
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
Battery Box 3
COMPONENT
TYPE
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2609P001
REV
next
= PCS
+ Ax3
Sh
of
9
10
C
8.0
See PLM
REVISED BY
8.6
HDC1-JB-9
8.3
HDC1-JB-8
8.9
HDC1-JB-7
9.8
HDC1-JB-6
8.8
HDC1-JB-4
8.6
HDC1-JB-3
8.3
HDC1-JB-2
8.8
GE Energy
See PLM
DRAWN
12-SEP-2007 A. Ridenour
ISSUED
See PLM
GENERAL ELECTRIC COMPANY
WIND ENERGY TECHNOLOGY
C
HDC1-JC-13
8.5
HDC1-JC-12
8.4
HDC1-JC-11
8.4
HDC1-JC-10
8.7
HDC1-JC-9
8.7
HDC1-JC-8
8.2
NC
NC
NC
JC-15
JC-16-25
RS-485 Shield
RS-485 +
RS-485 -
Thermistor -
Thermistor +
JB-3
JB-4
JB-5
JB-6
JB-7
JB-8
JB-9
JB-10
JB-11
JB-12
Supply Power
24Vdc In
NC
Light Power
NC
Battery Box Heater Neutral
Supply Neutral
24Vdc Out
NC
Light Neutral
JC-2
JC-3
JC-4
JC-5
JC-6
JC-7
JC-8
JC-9
JC-10
JC-11
JC-12
JC-13
JC-14
JC-15
JC-16-25
Connector ID Out
Battery Lockout Switch +
Battery Lockout Switch -
NC
NC
Battery Main. Switch +
Battery Main. Switch -
Thermistor +
Thermistor RS-485 RS-485 +
RS-485 Shield
NC
NC
NC
Battery Box 3
Axis-to-Battery Connector
JA-2
Battery Neg
COMP NO.
JB-2-6
NC
COMPONENT
COMP-PART NO.
104W2609P001
REV
TYPE
Documentation
HDP2-JC-10
6.7
HDP2-JC-9
Maintenance Mode
JC-11-25
JC-10
Thermistor -
6.7
HDP2-JC-4
6.1
HDP2-JC-3
6.1
HDP2-JC-2
6.0
HDP2-JC-1
6.0
NC
JC-9
Thermistor +
JC-4
Battery Lockout Switch -
JC-5-8
JC-3
Battery Lockout Switch +
NC
JC-2
JC-1
HDP2-JB-7
6.2
HDP2-JB-1
6.2
Connector ID Out
Connector ID In
JB-7
Battery Neg
8-12
JB-1
Operation Mode
Battery +24V
HDP2-JA-2
4.0
HDP2-JA-1
3.3
JA-1
Battery Pos
HDP1-JC-13
6.4
HDP1-JC-12
6.3
HDP1-JC-11
6.4
HDP1-JC-10
6.7
HDP1-JC-9
6.7
HDP1-JC-8
6.6
HDP1-JC-7
6.5
HDP1-JC-4
6.5
HDP1-JC-3
6.5
HDP1-JC-2
6.5
HDP1-JC-1
6.5
Heavy-Duty Plug 2
JC-1
Connector ID In
HDP1-JB-12
7.9
HDP1-JB-10
6.6
HDP1-JB-9
7.9
HDP1-JB-8
7.5
HDP1-JB-6
7.9
HDP1-JB-4
6.6
HDP1-JB-3
7.9
HDP1-JB-2
7.5
JC-14
JC-13
JC-12
JC-11
JC-10
JC-9
JC-7
JC-8
NC
NC
Connector ID Out
JC-6
JC-5
JC-4
JC-3
JC-2
Connector ID In
JB-2
JB-1
NC
HDP1-JA-2
4.0
HDP1-JA-1
4.0
HDC1-JC-7
8.1
HDC1-JC-4
8.2
HDC1-JC-3
8.1
HDC1-JC-2
8.5
JC-1
Light Neutral
JB-12
JA-2
Battery Neg
JA-1
Battery Pos
HDC1-JC-1
8.5
HDC1-JB-12
NC
24Vdc Out
Supply Neutral
Heater Neutral
JB-11
JB-10
JB-9
JB-8
Battery Neg
Light Power
JB-6
JB-7
NC
24Vdc In
Supply Power
Heater Power
Battery +24Vdc
Battery Neg
Battery Pos
JB-5
JB-4
JB-3
JB-2
JB-1
JA-2
JA-1
Heavy-Duty Plug 1
HDC1-JB-10
9
previous
REV
DESCRIPTION
8.9
HDC1-JB-1
8.1
HDC1-JA-2
9.8
HDC1-JA-1
Heavy-Duty Connector 1
0
9
+PS/1
= PCS
+ Ax3
of
Sh
next
10
10
Cover Page
GE Wind Energy 1.6MW
WTG Drw No.:
WTG No.:
Project/CMS No.:
Customer:
Component:
Comp No.:
Comp-Drw. No.:
Comp-Part No.:
Frequency:
Rated Voltage:
Control Voltage:
108W6614
16111805 - 813
Aratua-1 / 712835
BioEnergy
Pitch System
104W4611
104W2610P001
50/60 Hz
690V / 400V
230V / 24VDC
2
DATE
SIGNATURE
+Ax3/10
previous
REV
DESCRIPTION
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
ISSUED
25-APR-2008 G.Stultz
See PLM
DRAWN
25-APR-2008 G.Stultz
CHECKED
25-APR-2008 A. Ridenour
ENGINEER
4-DEC-2007
ISSUED
See PLM
next
GE Energy
Pitch System
Documentation
J. Melius
COMPONENT
TYPE
Pitch System
COMP NO.
= PCS
+ PS
Documentation
REV
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2610P001
Sh
of
1
8
date
revision
change
page
ECR
04/25/08
09/11/08
Updated Border
09-17-2010
5, 8
3000631
01-06-2011
+PS/5,+PS/8
3000631
1
previous
REV
DESCRIPTION
3
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
See PLM
COMPONENT
TYPE
Pitch System
COMP NO.
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2610P001
REV
next
= PCS
+ PS
Sh
of
2
8
Axis 1
0 and 90
LS Harnesses
Battery Enclosure
Limit Switches
Axis-to-Battery
Harness
Abs. Enc.
Harness
Center-to-Axis 1
Power Harness
Motor Power
Harness
Axis Enclosure
Absolute Encoder
(Optional)
Motor
Assembly
Motor Conduit
Box Harness
Brake, Heater,
RTD, Fan
Incremental
Enc. Harness
Center-to-Axis 1
Control Harness
Tach
Axis 2
Slip
Ring
Unit
Slip Ring
Harness
Center-to-Axis 2
Power Harness
0 and 90
LS Harnesses
Center Enclosure
Battery Enclosure
Limit Switches
Axis-to-Battery
Harness
Abs. Enc.
Harness
Motor Power
Harness
Axis Enclosure
Absolute Encoder
(Optional)
Motor
Assembly
Motor Conduit
Box Harness
Center-to-Axis 2
Control Harness
Brake, Heater,
RTD, Fan
Incremental
Enc. Harness
Tach
Hand-Held
Device
Hand-Held
Harness
Axis 3
0 and 90
LS Harnesses
Battery Enclosure
Axis-to-Battery
Harness
Abs. Enc.
Harness
Center-to-Axis 3
Power Harness
Motor Power
Harness
Axis Enclosure
Absolute Encoder
(Optional)
Motor
Assembly
Motor Conduit
Box Harness
Incremental
Enc. Harness
Center-to-Axis 3
Control Harness
2
previous
REV
DESCRIPTION
Limit Switches
Brake, Heater,
RTD, Fan
Tach
4
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
See PLM
Pitch System
Overview
COMPONENT
TYPE
Pitch System
COMP NO.
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2610P001
REV
next
= PCS
+ PS
Sh
of
3
8
X2.CB.1
X2.CB.1
X2.CB.1
X2.CB.1
X2.CB.1
11
16
14
12
10
19
24
22
20
18
SA1
L1
L2
L3
Main
AC Surge
Arrester
12
PE
11
T3
T2
T1
L3
L2
L1
PE
12
PE
11
12
11
Q2
1A
1B
1C
1A
1B
1C
FA3
FA1
FA2
10Amp,
690Vac
gG Fuse
10Amp,
690Vac
gG Fuse
10Amp,
690Vac
gG Fuse
2A
2B
2C
2A
2B
2C
1A
1B
1C
2A
2B
2C
3
previous
REV
DESCRIPTION
A2-L3SW
+Ax2/3.1
A2-L2SW
+Ax2/3.2
A2-L1SW
+Ax2/3.2
A1-L3SW
A1-L2SW
+Ax1/3.1
+Ax1/3.2
A1-L1SW
+Ax1/3.2
A3-L3SW
+Ax3/3.1
A3-L2SW
+Ax3/3.2
A3-L1SW
+Ax3/3.2
SA2-11
5.2
AEPC-J6-4
6.0
A3-PEGND
+Ax3/3.2
A2-PEGND
+Ax2/3.2
A1-PEGND
+Ax1/3.2
SR-PE
=SR+/4.1
SR-L1
=SR+/4.0
SR-L2
SR-L3
=SR+/4.0
=SR+/4.1
PE
5
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
See PLM
Center Box
690VAC Power Distribution
COMPONENT
TYPE
Pitch System
COMP NO.
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2610P001
REV
next
= PCS
+ PS
Sh
of
4
8
X3.CB.1
X3.CB.1
21
22
23
24
X3.CB.1
25
28
26
27
Lube Pump Power / 8.6
36
30
SA2
AC Surge
Arrester
5/L
L/6
1/N
N/2
X3.CB.1
32
37
34
39
40
CB1
41
X3.CB.1
42
43
38
44
47
49
46
5A, G-trip
45
3/GND
CHECKED BY
See PLM
REVISED BY
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
See PLM
Center Box
400VAC Power Distribution
COMPONENT
+Ax2/7.6
A2-HtrPwr
+Ax1/7.6
A1-HtrPwr
+Ax3/7.6
A3-HtrPwr
+Ax2/7.7
6
TYPE
Pitch System
COMP NO.
A2-HtrNeut
+Ax1/7.7
A1-HtrNeut
+Ax3/7.7
A3-HtrNeut
+Ax2/7.7
A2-SupplyPwr
+Ax1/7.7
A1-SupplyPwr
+Ax3/7.7
A3-SupplyPwr
+Ax2/7.7
A2-SupplyNeut
+Ax1/7.7
A3-SupplyNeut
6.0
GE Energy
A1-SupplyNeut
50
12
AEPC-J6-3
4.5
4
previous
REV
DESCRIPTION
SA2-11
SR-1PE
=SR+/4.3
SR-1N
=SR+/4.3
SR-1L3
=SR+/4.2
SR-1L2
=SR+/4.2
SR-1L1
=SR+/4.2
11
48
GND/4
+Ax3/7.7
29
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2610P001
REV
next
= PCS
+ PS
Sh
of
5
8
AEPC
1
E--STOP
P24
J6
P24SW
3
5.2 / AEPC-J6-3
Surge_Aux
5
C1
C3
8
8.4
C4
DM_SWP
10
B3
Manual = Open
Auto = Closed
(wh/or)
(or)
B4
(wh/gr)
B5
(gr)
14
ETRN
ETRP
ETXN
ETXP
MC_ON_A3
7.7
AOM_SWN
15
MC_ON_A2
7.2
P24
P24
P24SW
J8
1
8.1
A5
7.4
AOM_SWP
Man/Auto
Selector Switch
A2
BB_RUN
7.2
7.1
A1
7.1
DM_SWN
13
SL_SUP
7.2
7.1
12
C5
MC_ON_A1
11
B2
A4
7.2
AC2
Connector to External
Handheld Device
B1
AEPC-ENET
C2
8.1
JX
7.1
AC1
4.4 / AEPC-J6-4
2
PCOM
A3
P9
PCOM
J14
TB1
10
11
12
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
ETRN (Orange)
ETRP (White/Orange)
ETXN (Green)
ETXP (White/Green)
=SR+/5.4 / SR-21
=SR+/5.4 / SR-22
=SR+/5.4 / SR-23
=SR+/5.5 / SR-24
=SR+/4.8 / SR-10
=SR+/4.8 / SR-9
=SR+/4.9 / SR-12
=SR+/4.8 / SR-11
20
=SR+/4.7 / SR-8
19
=SR+/4.7 / SR-7
18
=SR+/4.6 / SR-6
17
=SR+/4.6 / SR-5
16
=SR+/4.5 / SR-4
15
Light Neutral
14
Light Power
13
=SR+/4.4 / SR-3
X4.CB.1
Outlet Neutral
12
=SR+/4.4 / SR-2
11
Outlet Power
10
=SR+/4.4 / SR-1
8.9
Handheld-ENET
5
previous
REV
DESCRIPTION
SR-18
/ SR-17
/ SR-16
/ SR-15
/ SR-14
/ SR-13
X6.CB.1
24VDC
Spares
24V RET
230Vac
50Hz version
115Vac
60Hz version
7
GENERAL ELECTRIC COMPANY
WIND ENERGY TECHNOLOGY
DRAWN
25-APR-2008 G.Stultz
ISSUED
See PLM
Center Box
Hand-Held & Slipring Conns
COMPONENT
TYPE
Pitch System
COMP NO.
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2610P001
REV
next
= PCS
+ PS
Sh
of
6
8
C
+Ax1/7.1
6
previous
REV
DESCRIPTION
See PLM
CHECKED BY
REVISED BY
GE Energy
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
See PLM
GENERAL ELECTRIC COMPANY
WIND ENERGY TECHNOLOGY
C
+Ax2/7.2
+Ax2/7.2
Center Box
Outputs to Axis Boxes
COMP NO.
+Ax3/7.2
+Ax3/7.2
COMPONENT
Pitch System
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2610P001
TYPE
Documentation
REV
A3-AEPA-J1-18
24Vdc Switched
16
+Ax3/7.3
15
A3-AEPA-J1-17
14
+Ax3/7.3
A3-AEPA-J1-15
13
+Ax3/7.3
A3-AEPA-J1-14
Deadman Switch -
12
+Ax3/7.2
A3-AEPA-J1-13
Deadman Switch +
11
+Ax3/7.2
6.7
MC_ON_A3
A3-AEPA-J1-12
10
+Ax3/7.2
A3-AEPA-J1-11
+Ax3/7.2
A3-AEPA-J1-10
A3-AEPA-J1-9
A3-AEPA-J1-8
+Ax3/7.2
A3-AEPA-J1-7
Mains Contactor On
+Ax3/7.1
P24
A3-AEPA-J1-6
+Ax3/7.1
A3-AEPA-J1-5
ID Input 1
+Ax3/7.1
A3-AEPA-J1-4
ID Input 0
J4
+Ax3/7.1
PCOM
A3-AEPA-J1-3
18
24V RET
17
+Ax3/7.1
4A
250Vac
A3-AEPA-J1-2
FU3
4A
250Vac
24VDC
FU2
4A
250Vac
+Ax3/7.1
FU1
A3-AEPA-J1-1
+Ax3/7.1
A2-AEPA-J1-18
24Vdc Switched
16
+Ax2/7.3
15
A2-AEPA-J1-17
14
+Ax2/7.3
A2-AEPA-J1-15
13
+Ax2/7.3
A2-AEPA-J1-14
Deadman Switch -
12
+Ax2/7.2
11
A2-AEPA-J1-13
Deadman Switch +
6.7
MC_ON_A2
+Ax2/7.2
A2-AEPA-J1-12
10
+Ax2/7.2
A2-AEPA-J1-11
+Ax2/7.2
A2-AEPA-J1-10
A2-AEPA-J1-9
A2-AEPA-J1-8
+Ax2/7.2
A2-AEPA-J1-7
Mains Contactor On
+Ax2/7.1
P24
A2-AEPA-J1-6
+Ax2/7.1
A2-AEPA-J1-5
ID Input 1
+Ax2/7.1
A2-AEPA-J1-4
ID Input 0
+Ax2/7.1
PCOM
A2-AEPA-J1-3
24V RET
+Ax2/7.1
J3
A2-AEPA-J1-2
18
24VDC
17
+Ax2/7.1
PCOM
A2-AEPA-J1-1
6.5
AOM_SWN
6.5
AOM_SWP
6.5
DM_SWN
6.5
+Ax2/7.1
A1-AEPA-J1-18
24Vdc Switched
16
+Ax1/7.3
15
A1-AEPA-J1-17
14
+Ax1/7.3
A1-AEPA-J1-15
13
+Ax1/7.3
A1-AEPA-J1-14
12
+Ax1/7.2
Deadman Switch -
DM_SWP
PCOM_CW
P24CW
6.5
Surge_Aux
6.7
BB_RUN
6.7
MC_ON_A1
A1-AEPA-J1-13
Deadman Switch +
11
+Ax1/7.2
A1-AEPA-J1-12
10
+Ax1/7.2
A1-AEPA-J1-11
+Ax1/7.2
A1-AEPA-J1-10
Surge Aux
+Ax1/7.2
A1-AEPA-J1-9
A1-AEPA-J1-8
+Ax1/7.2
A1-AEPA-J1-7
+Ax1/7.1
6.7
SL_SUP
AEPC
A1-AEPA-J1-6
Mains Contactor On
+Ax1/7.1
P24
A1-AEPA-J1-5
ID Input 1
+Ax1/7.1
A1-AEPA-J1-4
ID Input 0
+Ax1/7.1
A1-AEPA-J1-3
24V RET
+Ax1/7.1
A1-AEPA-J1-2
24VDC
J2
+Ax1/7.1
A1-AEPA-J1-1
0
8
9
P24SW
PCOM
17
18
= PCS
+ PS
of
Sh
next
7
8
AEPC
P24SW
J7
ES
BPPB
V1(+)
V1(-)
Communication Card
ENET
RJ45
Ports
PCOM
J4
J3
RJ45
RJ45
4
5
6
7
Ethernet Switch
6.5
6.5
AC1
10kOhm
Thermistor
AC2
6.8
AEPC-ENET
RJ45
J13
5.6 / Lube
Pump Power
P12
PE-GND
N
N
5.4 / Lube
230VAC
+Ax1/7.8
A1-X6.A.1-20
300W
PE
P
CB Heater Neutral
CB Heater Power
+Ax1/7.8
+Ax2/7.4
A2-AEPA-J2-2
+Ax2/7.4
A2-AEPA-J2-1
10kOhm
Hub Ambient
Thermistor
A1-X6.A.1-18
Light Neutral
+Ax3/7.8
A3-X6.A.1-16
Light Power
+Ax3/7.8
A3-X6.A.1-14
Light Neutral
+Ax2/7.8
A2-X6.A.1-16
Light Power
+Ax2/7.8
A2-X6.A.1-14
Light Neutral
+Ax1/7.8
A1-X6.A.1-16
Light Power
+Ax1/7.8
A1-X6.A.1-14
A1-AEPA-J2-2
+Ax1/7.4
Thermistor -
Thermistor +
L1
+Ax1/7.4
Pump Neut
A1-AEPA-J2-1
bl
rt
PE
+Ax3/7.0
A3-ENET
P11
+Ax1/7.0
A1-ENET
+Ax2/7.0
P10
A2-ENET
6.3
Handheld-ENET
J5
Option
previous
REV
DESCRIPTION
next
CHECKED BY
See PLM
REVISED BY
GE Energy
See PLM
DRAWN
25-APR-2008 G.Stultz
ISSUED
See PLM
Center Box
Ethernet, Light Power,
Heater, and Temp Outputs
COMPONENT
TYPE
Pitch System
COMP NO.
= PCS
+ PS
Documentation
COMP-DRW. NO.
104W4611
COMP-PART NO.
104W2610P001
REV
Sh
of
8