Professional Documents
Culture Documents
(COPIER>FUNCTION>CLEAR>ERR)
E001 There is an abnormal rise in temperature.
After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0001 There is an error or an open circuit in the main thermistor, shutter
thermistor, or sub thermistor.
- Check the connector of each thermistor for any fault in connection and wiring.
- Replace the thermistor in question.
- Replace the DC controller PCB.
0002 The reading of the main thermistor, shutter thermistor, or subthermistor is 230 C or higher for 2 sec.
- Replace the thermistor in question.
- Replace the DC controller PCB.
0003 The reading is not 150 deg C or higher or 210 deg C or lower within 30 sec.
-Cheak the connecting of the main/ sub/ shutter thermistors.
-Check the mounting of the main/ sub/ shutter thermistors.
-Exchange the main/ sub/ shutter thermistors.
-Exchange the DC controller PCB.
0010 The power has been turned off and then back on without resetting the error. - Reset the error.
(COPIER>FUNCTION>CLEAR>ERR)
E002 There is an abnormal rise in temperature.
After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0000 The reading of the main thermistor is not 100 deg C 12 sec after it has exceeded 70 deg C.
- Check the connector of the main/shutter thermistor for any fault in connection and wiring.
- Check the main/shutter thermistor for mounting condition.
- Replace the main/shutter thermistor.
- Replace the fixing heater unit.
- Replace the DC controller PCB.
0001 The reading of the main thermistor is not 150 deg C 15 sec after it has exceeded 100 deg C.
0010 The power has been turned off and then back on without resetting the error. - Reset the error.
(COPIER>FUNCTION>CLEAR>ERR)
E003 There is an abnormal rise in temperature.
After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0000 The reading of the main thermistor is lower than 70 deg C for 2 sec or more after it has exceeded 100
deg C.
- Check the connector of the main/shutter thermistor for any fault in connection and wiring.
- Check the main/shutter thermistor for mounting condition.
- Replace the main/shutter thermistor.
- Replace the fixing heater unit.
- Replace the DC controller PCB.
0010 The power has been turned off and then back on without resetting the error. - Reset the error.
(COPIER>FUNCTION>CLEAR>ERR)