You are on page 1of 3

CAPACITY OF SOIL ON SITE?

Suryakanta | February 23, 2015 | Geotechnical, How To, Soil, Soil Investigation | 2 Comments

This simple and quick field test will give you a rough idea of bearing capacity of soil.

Procedure
1. Excavate a pit of required depth. (preferably equal to the depth of foundation)
2. Take a solid ball or square cube of known weight and dimension.
3. Drop the ball or square cube several times, from a known height on to the bottom surface
of excavated pit.
4. Calculate the average depth of impression made several times on the bottom surface of
the excavated pit. Let d is the average depth of impression.

Calculation
Calculate the ultimate resistance of soil ( R ) using the formula given below.
R = (w * h) / d
Where,
R = Ultimate resistance of soil (in kg)
d = Average depth of impression (in cm)

w = Weight of the solid ball or square cube (in kg)


h = Height of fall of solid ball or cube (in cm)
If A is the cross-sectional area of the solid steel ball or cube, then resistance of soil per unit
area is calculated using following formula.
Resistance of soil per unit area (in kg/cm2) = R / A
Safe bearing capacity (in kg/cm2) = R / (A * F.O.S)
Where,
F.O.S = Factor of safety

Notes to Remember
1. F.O.S varies from 2 to 3 depending upon the type of structure and site condition.
2. In order to get reliable test result, perform this test on different types of soil and then use
your judgment to reach at any conclusion.
3. Instead of using solid steel ball or square cube, we can also use CBR test plunger, or
Cone (used for cone penetration test)

Presumptive Bearing Capacity


The table given below shows the presumptive bearing capacity values for different types of soils.
This table will guide you to reach at any conclusion after conducting the test.
Type of Soil / Rock
Rock
Soft rock
Coarse sand
Medium sand
Fine sand
Soft shell / Stiff clay
Soft clay
Very soft clay

Safe / Allowable Bearing Capacity (kg/cm2)


32.40
4.40
4.40
2.45
4.40
1.00
1.00
0.50

Notes to Remember
1. For non-cohesive soils the values should be reduced by 50% if the water table is above or
near base of footing.

2. These values should be used only for preliminary design. The actual bearing capacity of
soil should be calculated as per the standard codes.