Professional Documents
Culture Documents
DEEPAK MITTAL
01-04-15
02I
23.02.2015
EStad
DD
SW
01E
26.05.2014
DD
HFO
SW
Rev.
Date
Prepared
by
Reviewed
by
Approved
by
Area
Code:
System
Code:
M140
82
Project No.:
C-00011
S09011
No. of
Pages :
82EN0200
17
Rev.
51PO-04193.230-K-201-01
02I
Proj Rev.
-00
DN02-S09011-E-XK-3201-01
02I
Index
Item
Description
Page
1.
Table Of Content
2.
3.
4.
5.
6.
7.
8.
9.
10.
10
11.
11
12.
12
13.
13
14.
14
15.
1 5
16.
16
Acceptance Code:
1
.
.
.
.
.
.
DD
SW
01E
ISSUED FOR REVIEW
26.05.201 4 DD
HFO
SW
Description
Made by
Date
Chc. by
SMOE
82EN0200A
S09011
=82EN0200
Scale
M140
NTS
51PO-04193.230-K-201-01
Mustang
System:
Rev:
82
A4
02I
1
Wood Group
Appr. by
P.O.Number
Tag no.
Signature:
Area:
DET NORSKE
23.02.201 5 EStad
Date:
02I
ISSUED FOR CONSTRUCTION
Issue
Drawing Title:
Supplier
DN02-S09011-E-XK-3201-01
+01A1R2
Sheet:
Sheets:
16
<>
<8>
L1
L2
L3
No. / Text
MOTOR DRIVE
CLOSING COIL
TRIP COILS
F1 : SHUNT, F4 UVT
AUXILIARY CONTACTS
AUXILIARY CONTACTS
MAIN CIRCUIT
IN CONNECTED POSITION :
10
/1 3.2
/1 3.2
X7:3
X7:1
/1 3.1
X7:4
X7:6
/1 3.1
/1 2.2
X6:6
X5:6
X5:4
<7>
/6.2
/8.2
X5:10
X6:2
/7.6
=3203-01/9.2
/1 1 .6
/1 1 .5
X6:12
X6:10
X5:12
X5:13
/9.6
/9.6
/8.2
X6:13
/1 3.1
P2
P1
S2
L1.1
/3.1
L2.1
/3.1
L3.1
/3.1
-X40
<10>
-T01
-T02
-T03
4000/1 A, cl 1 , 5 VA
S1
S1
S1
P2
P1
S2
Q1
X7:2
X7:5
X6:5
/1 2.2
/6.2
=3202-01/7.4
S23
S22
/1 3.2
S20
X5:5
X5:3
X5:9
S4
/8.2
/7.7
X5:7
X6:3
/7.6
X6:1
/1 1 .6
=3203-01/9.2
X6:11
X6:9
/9.6
S3
S2
S1
X5:11
X5:14
/9.6
/8.2
X5:2
/6.1
F4
U <
/1 1 .5
F1
X6:14
Y1
X6:8
<6>
"MECH
ON"
"MECH
OFF" S11
/7.1
SEALED
/7.1
X6:7
/6.1
<5>
=3202-01/7.4
<4>
L1
L2
L3
-Q01
4000A
/7.7
<3>
X5:8
<2>
X6:4
<1>
SEALED
X5:1
P2
P1
S2
01
02
03
I1 /4.3
I2 /4.3
I3 /4.3
04
I0 /4.3
-PE
-X39
<11>
-T04
-T05
-T06
S1
4000/1 A, cl 5P30, 5 VA
S1
S1
P2
P1
S2
P2
P1
S2
P2
P1
S2
DETECTION (OPTION)
12
4
F20_I0
04
/1 0.1
-PE
2
4
-S35
-S34
-X67
<12>
-S33
-S32
2
4
2
4
2
4
CONNECTED
.
.
/1 1 .3
=3202-01/7.5
.
.
DET NORSKE
02I
ISSUED FOR CONSTRUCTION
23.02.201 5 EStad
DD
SW
01E
ISSUED FOR REVIEW
26.05.201 4 DD
HFO
SW
Issue
Description
Made by
Date
Chc. by
SMOE
Wood Group
Mustang
Appr. by
IE1
/1 0.1
IE2
/1 0.1
EXTERNAL CABLE
L2
L3
-PE
Acceptance Code:
Drawing Title:
Supplier
01
02
03
04
11/0,72kV TRANSF.
L1
-X41
.
.
BUS DUCT
PE
=3203-01/9.3
/1 1 .4
/7.1
/1 1 .4
-S31
1
-S30
TEST
2
4
2
4
OUT
Ivar Aasen_LV
SENTRON
3201-01
01
F20_I1
/1 0.1
02
F20_I2
11
/1 0.1
03
F20_I3
/1 0.1
Date:
P.O.Number
Tag no.
82EN0200A
Signature:
S09011
=82EN0200
Area:
Scale
M140
NTS
51PO-04193.230-K-201-01
System:
Rev:
Sheet:
82
A4
02I
DN02-S09011-E-XK-3201-01
+01A1R2
Sheets:
16
<1>
/2.7
No. / Text
L1.2
/4.1
L2.2
/4.1
L2.1
L3.2
/4.1
690/110VAC TRANSFORMER
I >
I >
I >
13
21
33
41
L3.1
/2.7
0,11A-0,16A
Set 0,11A
/1 2.2
/6.3
/6.3
/6.4
14
22
34
42
-Q02
B
A
-VT01
690
PE
110
3
110
n
a
Ivar Aasen_LV
SENTRON
3201 -01
<>
L1.1
/2.7
<2>
dn da
-X43
01
2U
/1 0.1
02
2V
/1 0.1
03
2W
/1 0.1
04
Acceptance Code:
1
.
.
.
.
DD
SW
01 E
ISSUED FOR REVIEW
26.05.201 4 DD
HFO
SW
Description
Made by
Date
Chc. by
SMOE
82EN0200A
S09011
=82EN0200
Scale
M140
NTS
51PO-04193.230-K-201-01
Mustang
System:
Rev:
82
A4
02I
3
Wood Group
Appr. by
P.O.Number
Tag no.
Signature:
Area:
DET NORSKE
23.02.201 5 EStad
Drawing Title:
Date:
02I
ISSUED FOR CONSTRUCTION
Issue
Supplier
DN02-S09011-E-XK-3201-01
+01A1R2
Sheet:
Sheets:
16
<>
<1>
14
22
34
42
6
W
I >
I >
I >
MULTI INSTRUMENT
/1 2.2
/6.4
/6.5
/6.2
0,11A-0,16A
Set 0,11A
No. / Text
13
21
33
41
-Q03
690 V AC
L1.2
/3.3
L2.2
/3.3
L3.2
/3.3
-VT02
690 V / 110 V
-X44
01
02
03
04
V1
V2
V3
VN
PE
DI-
11
12
13
<2>
Ivar Aasen_LV
SENTRON
3201 -01
DI+
DI
-P01
7KM21 1 2-0BA00-3AA0
1L1 .1
1L1.2
DO-
DO+
DO
F20:C1
/1 0.6
L/+
AUX supply
F20:C2
/1 0.6
N/-
I1
/2.7
I2
/2.7
I3
/2.7
E
I0
/2.7
Acceptance Code:
1
.
.
.
.
.
.
DD
SW
01E
ISSUED FOR REVIEW
26.05.201 4 DD
HFO
SW
Description
Made by
Date
Chc. by
SMOE
82EN0200A
S09011
=82EN0200
Scale
M140
NTS
51PO-04193.230-K-201-01
Mustang
System:
Rev:
82
A4
02I
4
Wood Group
Appr. by
P.O.Number
Tag no.
Signature:
Area:
DET NORSKE
23.02.201 5 EStad
Date:
02I
ISSUED FOR CONSTRUCTION
Issue
Drawing Title:
Supplier
DN02-S09011-E-XK-3201-01
+01A1R2
Sheet:
Sheets:
16
<1>
<2>
<3>
<4>
<6>
<5>
<8>
<7>
I >
4
13
21
/1 2.2
/6.5
I >
2
2A
F02:2
/6.1
F03:2
/7.1
F04:2
/1 0.6
F05:2
/8.2
F06:2
/1 6.1
F07:2
/9.1
F02:4
/6.1
F03:4
/7.1
F04:4
/1 0.6
F05:4
/8.2
F06:4
/1 6.1
F07:4
/9.1
-U01
AC
230V AC/24V DC
MOTOR DRIVE
CONTROL
PROTECTION DEVICE/
MULTI INTRUMENT
DC
L+
14
22
13
21
14
22
13
21
I > I >
-F07
/1 2.2
/6.5
2A
I >
I >
-F06
/1 2.2
/6.5
14
22
13
21
2A
I >
-F05
/1 2.2
/6.4
14
22
1
I >
2A
14
22
I >
-F04
/1 2.2
/6.4
I >
2
-F03
2A
13
21
13
21
14
22
3
4
I > I >
PE
2A
/1 2.2
/6.3
I > I >
L1
-F02
/1 2.2
/6.3
14
22
13
21
UPS/L2/82EN0200+01
=3210-01/2.2
3A
No. / Text
230V AC
UPS/L1/82EN0200+01
=3210-01/2.2
-F01
-X60
0V
<>
0V_1
/1 1 .2
Ivar Aasen_LV
SENTRON
3201 -01
2
24V+_1
/1 1 .2
+24V DC
-X60
24V+_2
/1 2.1
Acceptance Code:
1
.
.
.
.
DD
SW
01E
ISSUED FOR REVIEW
26.05.201 4 DD
HFO
SW
Description
Made by
Date
Chc. by
SMOE
Area:
Scale
M140
NTS
51PO-04193.230-K-201-01
Mustang
System:
Rev:
Sheet:
82
A4
02I
Wood Group
Appr. by
P.O.Number
Tag no.
Signature:
DET NORSKE
23.02.201 5 EStad
Date:
82EN0200A
02I
ISSUED FOR CONSTRUCTION
Issue
Drawing Title:
Supplier
S09011
=82EN0200
DN02-S09011-E-XK-3201-01
+01A1R2
Sheets:
16
<1>
<>
<2>
230V AC
No. / Text
F02:2
/5.2
12
11
10
33
-Q03
/4.2
-Q03
/4.2
22
42
22
21
-Q02
/3.2
34
-Q02
/3.2
34
-Q02
/3.2
-Q01 -S4
/2.2
41
21
33
X5:6
-X100
28
27
26
25
24
23
22
21
20
19
18
17
16
15
13
-X1 00
14
X5:5
22
21
22
-F07
/5.7
-F06
/5.6
22
22
-F05
/5.5
21
21
21
21
-F04
/5.4
22
42
-F03
/5.3
X5:1
-F02
/5.2
22
-F01
/5.1
22
-Q03
/4.2
21
21
41
/2.2
S11
X5:2
Ivar Aasen_LV
SENTRON
3201-01
-Q01
F02:4
/5.2
Acceptance Code:
1
.
.
.
.
DET NORSKE
02I
23.02.201 5 EStad
DD
SW
01 E
26.05.201 4 DD
HFO
SW
Issue
Drawing Title:
Supplier
Description
Made by
Date
Chc. by
SMOE
Wood Group
Mustang
Appr. by
Date:
P.O.Number
Tag no.
82EN0200A
Signature:
S09011
=82EN0200
Area:
Scale
M140
NTS
51PO-04193.230-K-201-01
System:
Rev:
Sheet:
82
A4
02I
DN02-S09011-E-XK-3201-01
+01A1R2
Sheets:
16
<1>
<6>
<7>
<8>
F03:2
/5.3 -X30
<>
<9>
No. / Text
230V AC
REMOTE : SAS
2
EXTERNAL CABLE
=80EH0011A
2
4
+15
-S31
/2.1
X6:4
-Q0X
C11
BO1
C9
5
INTERLOCK FROM OTHER C.B.
INCOMER B
BO5
11
E5
6
REMOTE BYPASS INTERLOCK 2/3
12
BUSTIE
INCOMER B
C.B. CLOSED
SIGNAL LAMP
C.B. OPEN
SIGNAL LAMP
-H03
X1
X1
-H02
15
F03:4
/5.3
Acceptance Code:
1
.
.
.
.
.
.
Drawing Title:
Supplier
DET NORSKE
02I
23.02.201 5 EStad
DD
SW
01E
26.05.201 4 DD
HFO
SW
Issue
Description
18
17
-X30
X2
X2
X2
X6:8
14
-H01
-X30
-X30
16
X1
-X30
CUBICLE NO.:+03A1R2
-X30
13
Y1
32
2
4
-S33
28 X5:3
/2.2
26
2
4
-Q01
-X30
-Q01
=3202-01/2.2
-S4
27 X6:1
-S33
=3203-01/2.2
X6:2
X6:7
-X30
-Q01
=3203-01/2.2 -S2
-X30
X5:4
-X30
29
<5>
28
<4>
=3202-01/2.2
C10
-X30
10
-F20
/1 0.2
BUS TIE
X5:7
E6
EXTERNAL CABLE
-Q01
/2.2 -S3
-S2
X6:3
<2>
C13
C12
<3>
-F20
/1 0.2
C14
-F20
/1 0.2
BO2
-X30
3
CLOSING PERMISIVES
X5:8
-Q01
/2.2
Ivar Aasen_LV
SENTRON
3201 -01
Made by
Date
Chc. by
SMOE
Wood Group
Mustang
Appr. by
Date:
P.O.Number
Tag no.
82EN0200A
Signature:
S09011
=82EN0200
M140
NTS
51PO-04193.230-K-201-01
System:
Rev:
Sheet:
82
A4
02I
Area:
Scale
DN02-S09011-E-XK-3201-01
+01A1R2
Sheets:
16
<1>
3
<3>
<4>
<3>
<5>
<7>
<6>
<>
<8>
(50ms)
REMOTE : SAS
C.B. OPEN
C.B. OPEN
C.B. OPEN
BY LOAD SHEDDING
19
8
A1
A2
X2:1 6
-X46
02
-F30
-Q0X
-R1
-K13
/1 3.7
IN
X2:15
-F32
/1 5.2
E3
BO4
-F20
/1 0.2
31 X1:9
X2:15
-F31
/1 4.2
X2:1 6
E4
-X30
<2>
01
12
14
INC. B
-K4
<U>
/.6
33k
11
+02A1R2
X1:10 30
EXTERNAL CABLE
+15
=80EH0011A
=3202-01/16.2
-X46
-X80
16
15
14
EXTERNAL CABLE
12
10
-X80
13
-X30
11
-Q01
/2.2 S3
-R2
-R3.1
4,7k
1,5k
X5:9
21
-X30
22
-R3.2
47k
X6:13
No. / Text
20
230V AC
F05:2
/5.5 -X30
X5:10
-R3.3
1 ,5k
-Q01
/2.2
-R4
-R5
F1
1k
-X30
24
F05:4
/5.5
25
X6:14
23
Ivar Aasen_LV
SENTRON
3201 -01
4,7k
-K4
14
/1 2.6 11
12
Acceptance Code:
1
.
.
.
.
DET NORSKE
23.02.201 5 EStad
DD
SW
01E
ISSUED FOR REVIEW
26.05.201 4 DD
HFO
SW
Description
Made by
Date
Chc. by
SMOE
Wood Group
Mustang
Appr. by
Drawing Title:
82EN0200A
P.O.Number
Tag no.
02I
ISSUED FOR CONSTRUCTION
Issue
Supplier
Date:
Signature:
S09011
=82EN0200
Area:
Scale
M140
NTS
51PO-04193.230-K-201-01
System:
Rev:
Sheet:
82
A4
02I
DN02-S09011-E-XK-3201-01
+01A1R2
Sheets:
16
<3>
<1>
<4>
<5>
<6>
<7>
<8>
<>
<9>
230V AC
15
14
-X46
10
-X90
11
No. / Text
F07:2
/5.7
(73ms)
REMOTE : SAS
C.B. OPEN
BY LOAD SHEDDING
C.B. OPEN
SPARE TRIP
C.B. OPEN
SPARE TRIP
C.B. OPEN
SPARE TRIP
10
EXTERNAL CABLE
+15
=80EH0011A
13
-K12
/13.5
E1
13
BO3
<2>
21
-Q0X
-K11
/13.4
-F20
/1 0.2
-K1 3
/1 3.7
14
14
E2
22
24
03
-X46
04
EXTERNAL CABLE
12
-X90
16
13
-Q01
-Q01
/2.2
F4
U<
E
X5:11
Ivar Aasen_LV
SENTRON
3201-01
INCLUDE A JUMPER TO BYPASS K11 & K12 RELAY CONTACTS, AS CB TRIPS AT ESD2
AT 11KV.PSD IS NOT USED AT INCOMER.
INCLUDE A NOTE TO SAY, JUMPER TO BE REMOVED, IF ESD/PSD USED.
X5:12
X5:13
X5:14
<10>
F07:4
/5.7
Acceptance Code:
1
.
.
.
.
DET NORSKE
02I
23.02.201 5 EStad
DD
SW
01E
26.05.201 4
DD
HFO
SW
Issue
Supplier
Description
Made by
Date
Chc. by
SMOE
Wood Group
Mustang
Appr. by
Drawing Title:
Date:
P.O.Number
Tag no.
82EN0200A
Signature:
S09011
=82EN0200
Area:
Scale
M140
NTS
System:
Rev:
Sheet:
82
A4
02I
DN02-S09011-E-XK-3201-01
+01A1R2
Sheets:
1 6
2U
/3.4
2V
/3.4
-X45
01
-X85
82EN200_2U_BUS A
=3203-01/3.6
02
82EN200_2V_BUS A
=3203-01/3.6
03
F04:2
/5.4
04
F04:4
/5.4
2W
/3.4
IE1
/2.7
IE2
/2.7
DC L+
(AC)
LDC
COMMUNICATION PORT
B
System/service
interface
IEC 61850
IEC 61 870-5-103
Profibus DP
Modbus RTU
DNP 3.0
Ethernet Interface
DIGSI 4
RJ45
EL
OPT
Earthing at
rear of housing
Enter
Power Supply
BI11
BI10
BI9
BI8
BI7
BI6
BI5
Run
Error
BO5
BO4
BO3
BO2
BI4
OPERATION PANEL
Esc
BO1
BI3
BI1
VA, VAB,Vph-n
VB, VBC
IN, INS
IC
SIPROTEC 7SJ8081
IA
BI2
-F20
C2
C1
D13
/1 2.6
D14
/1 2.6
/1 2.6
F20_I0
D12
/1 1 .3
/1 1 .3
/1 1 .4
/1 1 .4
/1 1 .4
/1 1 .4
/1 1 .5
/1 1 .5
/1 1 .6
/1 1 .6
/1 2.2
/1 2.2
/1 2.3
/1 2.3
/1 2.4
F20_I1
F1
F2
F3
F4
F5
F6
F7
F8
/2.7
F20:C2
/4.5
C3
C4
C5
C6
C7
C8
D1
D2
D3
D4
D5
D6
D7
D8
D9
/2.7
F20_I2
E13
E14
F20:C1
/4.5
F20_I3
E9
E11
E12
/2.7
D10
/1 2.4
D11
/1 2.4
EL
OPT
PE
B4
B3
B2
B1
E7
/1 3.6
E10
/1 3.6
E8
/1 3.6
E
C10
/7.5
C11
/7.5
C9
/7.5
C12
/7.4
C14
/7.4
C13
/7.4
E2
/9.1
E1
/9.1
E4
/8.2
E3
/8.2
E6
/7.1
E5
/7.1
Ivar Aasen_LV
SENTRON
3201-01
/2.7
IB, IN2
COMMUNICATION TOPOLOGY
Acceptance Code:
REF.DWG.NO.: DN02-S09011-E-XI-3202-01
1
.
.
.
.
.
.
Drawing Title:
Supplier
DD
SW
01E
ISSUED FOR REVIEW
26.05.201 4 DD
HFO
SW
Issue
Description
Made by
Date
Chc. by
SMOE
82EN0200A
S09011
=82EN0200
Scale
M140
NTS
51PO-04193.230-K-201-01
Mustang
System:
Rev:
82
A4
02I
10
Wood Group
Appr. by
P.O.Number
Tag no.
Signature:
Area:
DET NORSKE
23.02.201 5 EStad
Date:
02I
ISSUED FOR CONSTRUCTION
DN02-S09011-E-XK-3201-01
+01A1R2
Sheet:
Sheets:
16
< >
No. / Text
<1>
<2>
<3>
<5>
<4>
24V+_1
/5.1
2
4
-S32
/2.1
-Q01
/2.2 -S1
-Q01
/2.2 -S1
C.B. OFF
1 = OFF
C.B. ON
1=ON
X6:11
X6:9
-S30
/2.1
-S35
/2.2
2
4
2
4
X6:12
X6:10
-X35
C
D3
-F20
/1 0.2
BI5
D4
D2
C8
BI2
C6
C4
-F20
/1 0.2
BI4
-F20
/1 0.2
BI3
-F20
/1 0.2
-F20
/1 0.2
D1
C7
C5
C3
BI1
Ivar Aasen_LV
SENTRON
3201 -01
0V_1
/5.1
0V_2
/1 2.1
Acceptance Code:
1
.
.
.
.
.
.
DET NORSKE
02I
ISSUED FOR CONSTRUCTION
23.02.201 5 EStad
DD
SW
01E
ISSUED FOR REVIEW
26.05.201 4 DD
HFO
SW
Issue
Drawing Title:
Supplier
Description
Made by
Date
Chc. by
SMOE
Wood Group
Mustang
Appr. by
Date:
P.O.Number
Tag no.
82EN0200A
Signature:
S09011
=82EN0200
Area:
Scale
M140
NTS
51PO-04193.230-K-201-01
System:
Rev:
82
A4
02I
11
DN02-S09011-E-XK-3201-01
+01A1R2
Sheet:
Sheets:
16
<>
<1>
<2>
<3>
<5>
<4>
No. / Text
<6>
13
24V+_2
/5.2
-F01
/5.1
-KA1
-K11
/13.4
=3210-01/2.4
LOAD SHEDDING
UPS SUPPLY OK
12
14
11
=3203-01 /12.4
16
1
2
-K4
/8.6
17
12
14
33
-S06
-X35
32
34
14
-X35
31
13
13
13
14
-K13
/1 3.7
-X35
-F06
/5.6
12
-K12
-KB1
/13.5
=3210-01/2.4
15
13
13
-X35
-F05
/5.5
-X35
24
34
14
-Q03
-F04
/5.4
BUSTIE
+03A1R2
23
14
-X35
14
X6:6
-Q01
/2.2 S20
BUSTIE
11
+03A1R2
-F03
/5.3
=3203-01/3.2
13
12
14
23
13
11
24
-F02
/5.2
11
-X35
-X35
10
14
14
-X35
X6:5
14
-F07
/5.7
BI10
D13
D12
D10
BI9
D11
D14
D8
14
D6
BI8
BI7
BI6
-Q03
/4.2
-F20
/1 0.2
-F20
/1 0.2
13
-F20
/1 0.2
Ivar Aasen_LV
SENTRON
3201-01
D7
13
D5
-Q02
/3.2
D9
14
-F20
/1 0.2
BI11
E
0V_2
/1 1 .6
Acceptance Code:
1
.
.
.
.
DET NORSKE
02I
23.02.201 5 EStad
DD
SW
01 E
26.05.201 4 DD
HFO
SW
Issue
Drawing Title:
Supplier
Description
Made by
Date
Chc. by
SMOE
Wood Group
Mustang
Appr. by
Date:
P.O.Number
Tag no.
82EN0200A
Signature:
S09011
=82EN0200
Area:
Scale
M140
NTS
51PO-04193.230-K-201-01
System:
Rev:
Sheet:
82
A4
02I
12
DN02-S09011-E-XK-3201-01
+01A1R2
Sheets:
16
<1>
<2>
<4>
<3>
<5>
<6>
No. / Text
SPARE CB
TRIPPED
C.B. TRIPED SIGNAL TO
SIGNAL TO
UPSTREAM 11kV FEEDER
11Kv FEEDER
<7>
A1
ESD TRIP
SIL3
PSD TRIP
SIL3
-K13
/.7
A2
E8
E7
E10
-K12
/.5
7SJ8081
A1 (+)
Y1
-K11
/.4
-X65
-X70
(SPARE SIGNAL)
EXTERNAL
CABLE
EXTERNAL
CABLE
EXTERNAL
CABLE
=80EH0011A
+16
=80EH0011B
ESD NODE
LOAD SHEDDING
EXTERNAL
CABLE
LOAD
SHEDDING
+15
1
2
3
-X65
-X65
-X66
-F20
/1 0.2
A2 (-)
Y2
X1:14
A1 (+)
Y1
X1 :13
-F30
/1 6.2
A2 (-)
Y2
X1 :11
-F30
/1 6.2
X1:12
X7:1
-Q01
/2.2 S23
X7:5
-Q01
/2.2
S22
X7:2
X7:3
X7:4
EXTERNAL
CABLE
PSD NODE
-X
-X
Ivar Aasen_LV
SENTRON
3201-01
<>
X7:6
-K13
-K11
14
/9.2
24
/1 2.4
14
/8.5 12
11
24
/9.4 22
21
34
/1 2.4 32
31
-K12
13
14
/9.4
24
/1 2.4
23
13
23
Acceptance Code:
1
.
.
.
.
DET NORSKE
23.02.201 5 EStad
DD
SW
01E
ISSUED FOR REVIEW
26.05.201 4 DD
HFO
SW
Description
Made by
Date
Chc. by
SMOE
Wood Group
Mustang
Appr. by
82EN0200A
Area:
Date:
P.O.Number
Tag no.
02I
ISSUED FOR CONSTRUCTION
Issue
Drawing Title:
Supplier
Scale
Signature:
S09011
=82EN0200
NTS
51PO-04193.230-K-201-01
+01A1R2
System:
Rev:
Sheet:
82
A4
02I
13
DN02-S09011-E-XK-3201-01
Sheets:
16
<>
of cubicle
Optic sensor
inside cubicles
busbar view
X1
OFF
CH.07
CH.08
CH.09
ON
CH.10
ON
PE
OFF
Trip T1
DO +24VDC
X2
CH.05
CH.06
ARC CHANNELS
DO GND
ERROR
DI GND
TRIP
Serial A
COM
Serial B
ACT
CAN-L
POWER
+24V
OK
CH.04
CH.03
DI (24-48VDC)
CH.02
CH.01
CAN-H
VAMP 10L
OFF
OFF
COM1
OFF
COM2
COM2
COM1
X2:16
/8.2
X2:15
/8.2
X2:1 4
X2:13
X2:12
X2:11
X2:1 0
X2:9
X2:8
X2:7
X2:6
X2:5
X2:4
X2:3
X2:2
OFF
PE
X1:20
X1:19
+19
-E01
X1:18
+17
-E01
2
1
X1:17
X1:16
X1:15
X1:14
X1 :9
X1:8
X1:7
X1:6
X1:5
X1:4
+15
-E01
1
2
DIP-switches
-F31
GND
X1 :3
X1:1
X1:2
<1>
+13
-E01
1
2
+11
-E01
1
2
X1:13
+09
-E01
1
2
X1:12
+07
-E01
1
2
X1:11
+05
-E01
1
2
X1:10
+03
-E01
1
2
+01
-E01
1
2
No. / Text
<2>
X2:1
<3>
ARC_BUS_2
/1 5.5
ARC_BUS_1
/1 6.1
D
VMP1_GND
/1 6.1
Ivar Aasen_LV
SENTRON
3201 -01
VMP1_+24V
/1 6.1
Acceptance Code:
1
.
.
.
.
DET NORSKE
02I
23.02.201 5 EStad
DD
SW
01E
26.05.201 4 DD
HFO
SW
Issue
Drawing Title:
Supplier
Description
Made by
Date
Chc. by
SMOE
Wood Group
Mustang
Appr. by
Date:
P.O.Number
Tag no.
82EN0200A
Signature:
S09011
=82EN0200
Area:
Scale
M140
NTS
51PO-04193.230-K-201-01
System:
Rev:
Sheet:
82
A4
02I
14
DN02-S09011-E-XK-3201-01
+01A1R2
Sheets:
16
<>
of cubicle
Optic sensor
inside cubicles
busbar view
DIP-switches
-F32
X1
OFF
CH.07
CH.08
CH.09
ON
CH.10
ON
PE
OFF
Trip T1
DO +24VDC
GND
X2
CH.05
CH.06
ARC CHANNELS
DO GND
ERROR
DI GND
TRIP
Serial A
COM
Serial B
ACT
CAN-L
POWER
+24V
OK
CH.04
CH.03
DI (24-48VDC)
CH.02
CH.01
CAN-H
VAMP 10L
OFF
OFF
COM1
OFF
COM2
COM2
COM1
X2:16
/8.3
X2:15
/8.3
X2:14
X2:13
X2:12
X2:11
X2:10
X2:9
X2:8
X2:7
X2:6
X2:5
X2:4
X2:3
X2:2
OFF
PE
X1:20
X1:19
X1:18
X1:17
X1:16
X1:15
X1:9
X1:8
X1:7
X1:6
X1:5
X1 :4
X1:2
X1 :1
X1:3
<1>
X1:14
+29
-E01
1
X1:13
+27
-E01
2
1
X1:12
+25
-E01
2
1
X1:11
+23
-E01
1
2
X1:10
+21
-E01
1
2
No. / Text
<2>
X2:1
<3>
ARC_BUS_2
/1 4.6
D
VMP2_GND
/1 6.1
Ivar Aasen_LV
SENTRON
3201-01
VMP2_+24V
/1 6.1
Acceptance Code:
1
.
.
.
.
DET NORSKE
02I
23.02.201 5 EStad
DD
SW
01E
26.05.201 4 DD
HFO
SW
Issue
Drawing Title:
Supplier
Description
Made by
Date
Chc. by
SMOE
Wood Group
Mustang
Appr. by
Date:
P.O.Number
Tag no.
82EN0200A
Signature:
S09011
=82EN0200
Area:
Scale
M140
NTS
51PO-04193.230-K-201-01
System:
Rev:
Sheet:
82
A4
02I
15
DN02-S09011-E-XK-3201-01
+01A1R2
Sheets:
16
<>
TRIP COMMAND
TO INC. C.B. B
TRIP COMMAND
TO BUS TIE CB
TRIP COMMAND
TO 11kV UPSTREM FEEDER B
TRIP COMMAND
TO 11kV UPSTREM FEEDER A
No. / Text
Mounted in instr
I>INT.
I>EXT.
-X61
PE
X1:19
X1:18
X1:17
X1:16
=3203-01/15.5
X1:15
=3203-01/15.5
X1:14
/1 3.3
X1:13
/1 3.3
X1:12
/1 3.3
X1:11
/1 3.3
X1:20
PE
OFF
OFF
OFF
POWER SUPPLY
COM1
OFF
COM2
COM2
COM1
X3:18
X3:1 7
X3:16
X3:15
X3:14
X3:13
X3:12
X3:1 1
X3:10
X3:9
X3:8
X3:7
X3:6
X3:5
X3:4
X3:2
OFF
<2>
+24V DC
VMP1_GND
/1 4.3
ON
0V
RS_B
GND
X3
IF(NC)
IF(NO)
SELF-SUPERVISION
Us
TEMP
CURRENT
Trip T4
Trip Alarm
Us
TRIP 4
RS_A
TEMP SET
-X61
X1:10
=3202-01/8.4
Trip T1
Trip T2
Trip T3
GND
TRIP 3
GND
ERROR
Lb>OUT
INFO
La>OUT
TRIP 2
I>IN/OUT
COM
Lb>OUT
INSTALL
ON
La>IN
TRIP 1
OFF
CAN_L
POWER
ERROR CODE
DIP-switches
CAN_H
RUN
X3:3
-PE9
X1
VAMP 221
MAIN UNIT
+24V
-F30
X1:9
=3202-01/8.4
<1>
X1 :8
=3203-01 /1 0.3
X1:7
=3203-01/10.3
X3:1
VMP1_+24V
/1 4.3
Ivar Aasen_LV
SENTRON
3201-01
VMP2_GND
/1 5.3
VMP2_+24V
/1 5.3
F06:2
/5.6
F06:4
/5.6
/1 4.6
ARC_BUS_1
Acceptance Code:
1
.
.
.
.
DET NORSKE
02I
23.02.201 5 EStad
DD
SW
01E
26.05.201 4 DD
HFO
SW
Issue
Drawing Title:
Supplier
Description
Made by
Date
Chc. by
SMOE
Wood Group
Mustang
Appr. by
Date:
P.O.Number
Tag no.
82EN0200A
Signature:
S09011
=82EN0200
Area:
Scale
M140
NTS
51PO-04193.230-K-201-01
System:
Rev:
82
A4
02I
16
DN02-S09011-E-XK-3201-01
+01A1R2
Sheet:
Sheets:
16