Example12.2.

4
Estimate the available net positive
suctionhead(NPSHA)foranewsystem
withtheconfigurationshowninFigure
12.2.2foradischargeof0.12

/ .The

suctionpipingandthedischargepiping
are both cement mortarlined ductile
iron pipe with a HazenWilliams
coefficient of 140. The suction piping
hasaninsidediameter(ID)of300mm
and a length of 5m. The static suction
headis+3m.Thesystemhasabellmouthentrance,two90degreebends,andagatevalveonthesuction
side.Theelevationisat1000mabovemeansealevel,thetemperatureis20degreeC,and

9.19 .