You are on page 1of 1

Berkman Systems, Inc.

VAG Building, Greenhills, San Juan City, Metro Manila

Constant Discharge Test


Pumping Well No. PBR 20
Location: PBR Housing Compound
BII Well No.:
Ground Elevation (mamsl):
Performed by: Berkman Systems, Inc.
Measuring Point
Description of Measuring Point

Date
10/15/14

Hour

3:00PM
3:01PM
3:02PM
3:03PM
3:04PM
3:05PM
3:06PM
3:07PM
3:08PM
3:09PM
3:10PM
3:12PM
3:14PM
3:16PM
3:18PM
3:20PM
3:25PM
3:30PM
3:35PM
3:40PM
3:50PM
4:00PM
4:15PM
4:30PM
5:00PM
5:30PM
6:00PM
6:30PM
7:00PM
8:00PM
9:00PM
10:00PM
11:00PM
10/16/14 12:00AM
1:00AM

Time after
start
(min)
0
1
2
3
4
5
6
7
8
9
10
12
14
16
18
20
25
30
35
40
50
60
75
90
120
150
180
210
240
300
360
420
480
540
600

Owner: Petron Corporation


Start: October 15, 2014
End: October 16, 2014
Duration: 24 hours

(mag)

Water
Level
(mbMP)
80.00
88.41
94.81
97.66
99.74
102.00
103.66
103.78
103.85
103.91
104.06
104.13
104.46
104.65
104.91
104.98
105.18
105.40
105.51
105.65
105.96
106.08
106.30
106.51
106.71
106.92
107.15
107.26
107.33
107.41
107.47
107.51
107.54
107.57
107.61

(mamsl)

Casing
Diameter
(mm)

Drawdown
(m)

Discharge
Rate
(lps)

8.41
14.81
17.66
19.74
22.00
23.66
23.78
23.85
23.91
24.06
24.13
24.46
24.65
24.91
24.98
25.18
25.40
25.51
25.65
25.96
26.08
26.30
26.51
26.71
26.92
27.15
27.26
27.33
27.41
27.47
27.51
27.54
27.57
27.61

Reducer
(mbg)

Screen Top
(mbg)

Remarks

54.50

56.90

55.86

EC = 0.287 mS

55.55

EC = 0.291 mS

54.80
54.35

55.37

Average Q= 55.27 lps