TYPICAL DETAILS OF BELOW GROUND EARTHING ot | oorso | ~se REVISED AS PER Ws TCE COMMENTS ie Ure ha Teese etme PO 340-VOT-08, DTD 13/2070. ten TATA CONSULTING ENGINEERS LIMITED 2250 MW LIGNITE BASED TPP PROJECT PADVA, DIST. BHAVNAGAR, GUJRAT 356 (cgi BHARAT HEAVY ELECTRICALS LTD. or fom [he] Stee | aia POWER SECTOR scat we [ta | sane CONTRACT afin PROJECT ENGINEERING MANAGEMENT © [om[ss—[-sa-| exon. NOIDA [APPEL ex [Se [ 200970 THe ATYPICAL DETAILS OF _ "DE_DG_356—509-R00t ‘BLOW_GROUND BATHING ser TOF e [AE CROSS JOINT 50X8 GALY. MS FLAT 300M LONG oui ov us ROD MAIN EARTH CONDUCTOR WELDED JOINTS _save) ne WELD SECTION 1-1 SECTION 2-2 65 (aN) [serve SECTION 5-8 NOTE: ‘ALL DIMENSIONS ARE IN MW. TYPICAL DETAILS OF BELOW GROUND EARTHING BHEL DRAWING NO. PE-DG-356-509—-E006 SH 2 OF 8 [oa She | sous os | enutha Tin Shar 2, Jos can 3) 40uM DIA wS—| us.R00 sro. NAM EARTAN Soni DETAIL="x’ COLUMN EARTHING Dien wor GRADE LEVEL (oa) = Beene voip —E cosy 5] vanes) A NA con RCC COVER SLAB (RENOVABLE) GRADE LEVEL —_70x600 Pir J 8h sear UN el i Bre feet tae gare Be a ‘SoAreD Wr BITUMEN EONPOUND) S008 os. ay ‘Wiibep 10 Hod (PROVIDED FOR CONNECTION BETWEEN VARIOUS GROUNDING SYSTEMS) Notts: TLL BWERSIONS ARE NW DEL DRAVING Ha, TYPICAL DETAILS OF (areas eT) copie BELOW GROUND EARTHING PE-DG-356-509- £006 SHS OF 8 1 COVER HINGED 25 TOC | FRAME \_ 7ow x 104 WALL “OPENING ‘ON FOUR SIDES FOR EARTH ‘CONDUCTOR ENTRY. Sh — Caw oma WATER PROOF SHALL BE PROVIDED_AT-THE TOP OF ‘CONCRETE BED. 150, “a= — 2 Qa Joocenous Eater eoee uy GHARCOAL, SAI AND SAND E WULD COVERED WITH oO. \\ — 9 O. DETAIL-A ‘NOTE: 1. ALL DIWENSIONS ARE IN Mid. 2. TOP OF PIT SHALL BE ALIGNED WITH GRADE LEVEL IN PAVED AREA, TYPICAL ARRANGEMENT OF PIPE ELECTRODE BHEL DRAWING NO. TYPICAL BELOW GROUND PE-DG-356-509-£006 EARTHING DETAILS ‘SH 4 OF B GRADE LEVEL 40 DIA MS ROD 3000 40 DIA. MS_ROD 4OMM_DIA MS ROD ELECTRODE 40 DIA. MS ROD ELECTRODE VERTICAL GROUND ELECTRODE SECTION AA (LOCATED ALONG PERIPHERY OF EARTHING GRID FOR USE OTHER THAN EARTH TEST PIT) GRADE LEVEL L 40 DIA MS w00 Ay] ryT* DIA MS ROD /-—40MM DIA MS ROD ELECTRODE 2 3 3 SECTION AA ;—40MM DIA MS ROD ELECTRODE VERTICAL GROUND ELECTRODE NOTES. (LOCATED AT JUNCTION OF EARTH CONDUCTOR’ 1. ALL DIMENSIONS ARE IN MM... ar BHEL DRAWING NO. in TYPICAL DETAILS OF PE-DG—356-509-E006 BELOW GROUND EARTHING SHS OF 8 ARC _WELD SECTION ~ (1) CROSS JOINT BETWEEN M.S ROD & G.S FLAT NOTES:— 1. ALL DIMENSIONS ARE IN M.M BHEL DRAWING NO. PE-DG-356-509-E006 TYPICAL DETAILS OF BELOW GROUND EARTHING SH 6 OF 8 NOTES: 1, WELDING OF GALVANISED FLAT/ MS ROD SHALL BE CARRIED OUT AS FOLLOWS:— a) CLEANING OF WELD AREA WITH WIRE BRUSH. b) REMOVAL OF GALVANISATION COATING IN THE WELD AREA. ¢) WELDING OF THE CONDUCTOR SHALL BE AS PER IS : 816. d) NATURAL COOLING OF WELDING JOINTS. 4. 2. THE EARTH CONDUCTOR BELOW GRADE LEVEL SHALL BE BARE 40 mm DIA MILD STEEL (M.S.) ROD. BELOW GRADE LEVEL. EARTH CONDUCTOR SHALL BE ROUTED BELOW ROADS/ RAIL TRACKS/TRENCHES WITH MINIMUM CLEARANCES AS UNDER : a) BELOW RAIL TRACK : MINIMUM 1000 MM b) BELOW ROAD/ CABLE TRENCHES/ PIPE TRENCHES : MINIMUM 300 MM. 3. DETAILS OF EARTH TEST PIT / TEST LINK PIT ARE INDICATIVE. ACTUAL DETAILS SHALL BE SHOWN IN CIVIL DRAWINGS & IS IN CIVIL SCOPE. 4, DRG. FOR DEPTH OF BURIAL OF MAIN CONDUCTOR SHALL BE FURNISHED. HOWEVER THE DEPTH OF BURIAL SHALL BE 600MM. 4. 5, POWER STATION GROUNDING GRID SHALL BE PROVIDED TWO INTER CONNECTIONS WITH TEST FACILITY TO INTER CONNECT WITH OTHER GRIDS. 4. 6. EARTH ELECTRODE AND TEST PIT ELECTRODE SHALL BE 40MM DIA X 3000MM DIA LONG MILD STEEL ROD DRIVEN INTO THE GROUND AND CONNECTED TO THE GROUND GRID CONDUCTOR. TEST PIT SHALL BE AS PER IS: 3043 4. 7, RISERS/PIGTAILS FROM THE GROUNDING GRID /RING SHALL PROJECT 300MM ABOVE GRADE /CONCRETE FLOOR LEVEL UNLESS OTHERWISE SPECIFIED. ALL RISERS PIG TAILS SHALL BE PAINTED GREEN FOR THE ABOVE GROUND PORTION. 4 8. THE INTERCONNECTED CONDUCTORS SHALL BE RUN PARALLEL TO AND AS CLOSE AS POSSIBLE TO THE INTERCONNECTING CABLE PATH ON PIPE CUM CABLE TRESTLE/ DUCT BANK/TRENCH AS APPLICABLE. 4 9. ALL SYSTEM NEUTRALS, GROUNDING TERMINALS OF SURGE ARRESTORS AND VOLTAGE TERMINALS SHALL BE CONNECTED TO TEST PITS, WHICH IN TURN ARE CONNECTED TO THE GROUNDING GRID. 4 10. EARTH PIT WITH RISER FOR SYSTEM NEUTRAL SHALL BE CONSTRUCTED AFTER ERECTION OF RELEVANT EQUIPMENT FOUNDATION. 411. ALL LIGHTNING PROTECTION DOWN CONDUCTORS SHALL BE CONNECTED TO DEDICATED) GROUND ELECTRODES THROUGH ISOLATING LINKS AND THEN TO THE GROUNDING SYSTEM. BHEL DRAWING NO. TYPICAL DETAILS OF PE_D¢—356-509-E006 BELOW GROUND EARTHING SH 7 OF 8 a 12. FOR ELECTRONIC GROUNDING,ONE NUMBER TREATED EARTH PIT SHALL BE PROVIDED FOR EACH UNIT. ONLY ELECTRONIC CONNECTIONS SHALL BE BROUGHT TO THE TEST PIT. NO OTHER EARTH CONNECTIONS SHALL BE PERMITTED. THE OTHER END CONNECTION FROM THE TEST PITS SHALL BE MADE TO STATION GROUND. ONLY SUCH CONNECTION SHALL BE MADE FROM EACH PIT. NO INTER CONNECTION PITS SHALL BE DONE BETWEEN THE TEST PITS. SUITABLE BIMETALLIC CONNECTORS SHALL BE USED FOR ALL CONNECTIONS. FOR FURTHER DETAILS OF ELECTRONIC GROUNDING, BHEL EDN DOCUMENTATION SHALL BE REFERRED. 13. THE ERECTION OF BELOW GROUND EARTHING SYSTEM SHALL COMPLY WITH THE REQUIREMENTS OF IS: 3043 CODE OF PRACTICE FOR EARTHING. one) BHEL DRAWING NO. in TYPICAL DETAILS OF PF-DG-356-509-F006 BELOW GROUND EARTHING SH 8 OF &

You might also like