ENGINEERED EFFICIENCY
Manual
Copyright
Copyright 2002 CAXperts GmbH. All Rights Reserved.
Including so6ware, le formats, and audiovisual displays; may be used pursuant to applicable so6ware licence agreement; contains conden;al and proprietary informa;on of CAXperts and/or third par;es which is protected by copyright law, trade secret law, and interna;onal treaty, and may not be provided or otherwise made available without
proper authoriza;on.
Trademarks
CAXperts is a registered trademark of CAXperts GmbH. Intergraph, the Intergraph logo, SmartSketch, FrameWorks,
SmartPlant, INtools, MARIAN, PDS, IGDS, RIS and IntelliShip are registered trademarks of Intergraph Corpora;on. IGDS
le formats 1987-1994 Intergraph Corpora;on. Microso6 and Windows are registered trademarks of Microso6
Corpora;on. Bentley, the Bentley logo B, and MicroSta;on are registered trademarks of Bentley Systems, Inc.
ISOGEN is a registered trademark of Alias Limited. Other brands and product names are trademarks of their respec;ve
owners.
Introduc on
Contents
1
Introduc on................................................................................................................. 4
1.1
Installa on................................................................................................................... 4
2.1
Uninstall ..................................................................................................................... 5
Setup command line (for administrators) ................................................................. 5
Licence ....................................................................................................................... 5
Site licence (local) ...................................................................................................... 5
Floa;ng (server) licence ............................................................................................ 6
3.2
3.3
3.4
3.5
3.6
3.7
3.8
4
Introduc on
ReportAdapter for SmartPlant 3D is designed to export a SmartPlant 3D aQributes and grac
into a SQL Lite database, containing one table per task. The resul;ng records are compressed
and internally resolved by code lists.
1.1
Typefaces
Italic
Bold
Indicates a command name, parameter name, or dialog box ;tle. Command paths are shown using an arrow between command names. For example,
Choose File Open to load a new le.
Normal
typewriter
Bold typewriter
Symbols
This document uses the following symbols to iden;fy special informa;on:
Note important supplemental informa;on.
Map or path shows you how to get to a specic command or form.
More informa;on indicates there is addi;onal or related informa;on.
Installa on
Requirements:
Installa on
Microso6 Windows 7, 8
Intergraph SmartPlant 3D 2009 SP5 or later
Administrator rights are required on each computer to install CAXperts ReportAdapter for
SmartPlant 3D. Run as is not supported.
Uninstall
To uninstall the so6ware, select Control panel from the start menu. Then on in large or small
icon view, click Programs and features. If you're using category view, under Programs, click Uninstall a program.
Select the program you want to remove, and click Uninstall/Remove. Alterna;vely, right-click the
program and select Uninstall.
This will cause the session variables in the INI le to be used for the setup. The INI le should be
in the format:
[SetupValues]
%AppFolder%=C:\Program Files\MyProduct
2.1
"/U:C:\Program
Files\MyProd-
Licence
CAXperts so6ware supports two types of licences:
The licence le has to be stored on a local or network loca;on accessible by the machine running
the CAXperts product; a licence server is not required.
The loca;on of the licence le should be dened on every machine with the CAXperts product
installed, which can be done
Every computer name must be preceded by the @ symbol. Mul;ple licence server loca;ons
should be separated by semicolons (;).
YourServerName is the Windows computer name of the machine running lmadmin (FlexNET
server). If lmadmin is running on a non-default port, the port number should be dened like this:
port@ YourServerName.
Note: Changes to the server path (in the environment variable or registry key) are read
during the next start of the CAXperts product.
Installa on
Borrowed licences
Licence seats can be borrowed for a period of ;me from the server and saved to the local machine. Once the seat has been borrowed the CAXperts applica;on can be used without any connec;on to the FlexNET server.
To borrow a licence seat press the Borrow seat buQon, dene the loan period (up to 7 days) and
press OK. When the borrowed seat expires it gets automa;cally returned back to the FlexNET
server.
The seat can be returned earlier by pressing the Return borrowed seat buQon.
Note: Without a valid licence le the so6ware will run in demo mode.
The ReportAdapter for SmartPlant 3D is used to extract SmartPlant 3D data out of an exis;ng
project like Material-Take-O (MTO) of all SmartPlant 3D. The extrac;on of all data can be done
without any knowledge of SP3D specic Report Crea;on. The philosophy is to use the
SmartPlant 3D Workspace Filters for crea;on of discipline specic reports.
Note: ReportAdapter for SmartPlant 3D requires SmartPlant 3D and a SmartPlant 3D
(S3D) licence seat on a SmartPlant Licence Server.
3.1
Select plant
Start ReportAdapter for SmartPlant 3D and select your Model Plant from the Plant Combo Box:
Select lter
To select a lter, click on the Filter Combo Box and select More lters.
A window will open where all lters are listed, please select lter and click OK.
Select output
Browse with the Browse buQon to select a loca;on to create a Microso6 Access Database le
in which the results will be shown.
All the seOngs are stored automa;cally in the congura;on le which is found under Tools
Se;ngs.
3.2
Congure a>ributes
ReportAdapter for SmartPlant 3D contains a predened set of aQributes which are reported
by default. Addi;onally customer can dene and congure own aQributes. No database specic
or programming knowledge is required for customiza;on of reportable Smart Plant 3D aQributes. A table is a combina;on of aQribute sets, columns with iden;cal names will be ver;cally
aligned.
10
A>ribute set
Each table consists of one or more aQribute sets. Each aQribute set holds the data for a specic
top node. The result of one or more aQribute sets is grouped together in the table they belong
to in the output database.
Drag and drop an aQribute to the table on the right side. The aQribute will then appear under
the AQribute set.
11
The type selected here denes the main item used for repor;ng, e.g. pipe component run:
pipe component selected only runs that belong to the component are listed; run selected
also empty runs get listed.
Press OK to nish the congura;on.
Note: The changes will be applied on the next extrac;on
Note: SmartPlant 3D labels can be used similar to the direct object aQributes.
12
Numeric values
Find
Select Find from the Edit menu to search for the available aQributes:
Enter the search text in Find what and dene the task name in Look in to search for the aQribute
in the given task:
13
3.3
Extrac on Geometry
ReportAdapter for SmartPlant 3D allows extrac;on of geometry from Smart 3D, which is used
by CAXperts Universal Plant Viewer and CAXperts S3D2PDS so6ware.
Tick on Extract Geometry op;on and select exis;ng 3D DGN drawing.
Prerequisites
1. Bentley MicroSta;on J (V7) has to be installed on the Worksta;on.
2. Empty 3D DGN-drawing has to be created through the Smart 3D Drawing Console, e.g.
like this:
This 3D DGN Drawing is by ReportAdapter for SmartPlant 3D for the geometry extrac;on. The user needs the permission to update this drawing.
3.
14
Permission to create new filter in the folder (Plant filters\3D ReportAdapter by default).
3.4
Generate VUE le
If enabled, ReportAdapter for SmartPlant 3D generates VUE le with aQributes as dened in
aQributes congurator.
3.5
Extrac on
To start extrac;on of aQributes and geometry if enabled click on Extract.
3.6
15
Tables that can be used in the queries are those that will be created during extrac;on. Addi;onal
tables (if needed) have to be copied before extrac;on to the Template.mdb database which can
be found in the applica;on folder.
When the template is used, the %TABLE1% and %COLUMN1% elds will be lled with the table
name and column name selected in the %TABLE1% and %COLUMN1% elds.
Note: The %TABLE1% and %COLUMN1% elds are lled from the Access database dened for
extrac;on output, which also includes the tables from Template.mdb. This means, the elds
are only lled a6er the extrac;on was performed once.
16
With the Show hidden tables eld checked, all tables of the database can be selected to build
the query. If it is not checked, only tables that will be displayed in UniversalReporter are available
and tables created for internal use are hidden.
Fill in the text of SQL statement and the Placeholders for Tables and columns to be used by
query textboxes by using the %TABLE"1% and %COLUMN1% buQons.
User dened templates can be deleted or modied using the Remove or Edit buQons.
Note: The SQL text boxes support syntax highligh;ng.
3.7
Se;ngs
All program seOngs (selected tasks and lters, aQributes, units of measure ) are stored automa;cally for each plant in the congura;on le located by default in the user prole folder. The
loca;on of the congura;on le can be changed by using menu Tools>Se;ngs.
17
General
Add manual extract info: if enabled shows following dialog before extrac;on where the user can
provide addi;onal informa;on evaluated by CAXperts UniversalReporter.
18
Clean-up style rules and lter before extrac on (dont use parallel extrac ons): if geometry
extrac;on is enabled this op;on removes all temporary style-rules and lters might le6 from last
run of the so6ware. In normal case You must not use this op;on when you run more the one
extrac;on of ReportAdapter for SmartPlant 3D on your project at the same ;me.
The rules are executed top->boQom. If no Style rules dened standard colours and MicroSta;on levels are used.
Drawings
Denes Isometric and Composed drawings to extract.
19
Save se;ngs to le
To export the seOngs from the plant congura;on le use menu File Save se;ngs to le.
Note: The loca;on of the plant congura;on le is not aected
20
Technical support
3.8
-config config_file.ini
Cong le which contains the seOngs for the extrac;on. If a congura;on le is not dened, the last congura;on will be used
Filter name from S3D Plant. Can be a Plant Filter or
from My Filters. If a lter is not dened, the last congura;on will be used
Output database. If Output database is not dened,
the last congura;on will be used
Clean le6over temporary S3D3PDS-specic rules. This
is an op;onal seOng.
Path to the 3D DGN-Drawing from S3D Drawing console
If this switch is set, S3D2PDS generates a PD_XPDA
Backup le.
-filter filter_name
-output output_file.mdb
-cleanrules
-drawing
-extractgeometry
Technical support
Need more help? Contact CAXperts support by email, online, or phone:
mailto:support@caxperts.com
hQp://www.caxperts.com/contact/