Professional Documents
Culture Documents
A-2
2.05
16.00
W1
W1
W1
W1
W1
W1
W2
1.45
W1
3
A-2
W1
W1
W1
W1
W1
1.00
W1
W1
UP.
W1
W1
W1
W1
W1
D1
T&B
BATH
PTR. MIKE
BEDROOM
DN.
D1
W1
W1
W1
W1
W1
C O R R I D O R
W1
W1
W1
JELOUPLUS
WINDOW, TYP.
2ND F.F.L
DN.
EXIT
W1
PLASTER
CEMENT
FINISH
8
A-2
2.51
1.25
W1
BATH
5
A-2
D1
CEILING LINE
D1
STEEL PIPE
STAIR RAILING
E X I S T I N G
S T R U C T U R E
C O R R I D O R
F. F. L.
0.20
D1
W1
W1
8
A-2
1.25
8
A-2
TOILET
TOILET
1.25
D1
UP.
W1
W2
BEDROOM
3.54
D1
1.00
BATH
D2
BATH
W1
D2
8
A-2
6.25
W1
5.00
1.00
D2
D2
BATH S T
BATH
X I S T I N G
R U C T U R E BEDROOM 2
W1
BEDROOM 1E
5.00
W1
1.25
5
A-2
1.00
D2
TOILET
W1
1.00
D2
D2
D2
TOILET
W1
2.30
W1
1.16
W1
A
TOILET
APEX OF STRUCTURE
0.40
W1
2.70
W2
G. I. FLASHING
4.00
3.20
W2
2.60
7.26
1.40
A
3
A-2
5.00
1.40
TOILET
2.05
2.05
2.49
W1
2.50
W1
W1
1.50
W1
W1
1.75
D2
W1
2.25
D2
W1
2.60
4.00
D2
4.00
4.00
1.25
2.05
6
A-2
D2
7
A-2
D2
6
A-2
4.00
1.05
2.05
4.00
4.00
8.00
3
4
A-2
16.00
6
A-2
2m
1.05
2.05
4
A-2
JELOUPLUS WINDOW
G. I. FLASHING
6
A-2
SCALE: 1:100
LEFT-SIDE ELEVATION
2m
SCALE: 1:100
2m
APEX OF STRUCTURE
APEX OF STRUCTURE
0.50
N. G. L.
F. F. L.
0.55
BATH
TOILET
TOILET
0.20
N. G. L.
BATH
F. F. L.
0.20
F. F. L.
E X I S T I N G
S T R U C T U R E
1.60
E X I S T I N G
S T R U C T U R E
2.70
3.20
3.20
3.40
S T R U C T U R E
1.20
2ND F.F.L
G. I. STEEL PIPE
STAIR RAILING
E X I S T I N G
2.10
1.20
2.10
BEDROOM
0.90
2ND F.F.L
0.55 0.50
7.26
PLASTER
CEMENT
FINISH
TYPE
2.15
0.90
1.16
1.18
CEILING LINE
2.70
2.70
2.82
2ND F.F.L
0.70
1.20
0.76
STEEL PIPE
STAIR RAILING
7.27
2.70
G. I. STEEL PIPE
STAIR RAILING
1.18
7.26
CEILING LINE
1.20
2.66
CEILING LINE
1.48
1.17
1.16
0.90
WOODEN LOUVERS
F. F. L.
D1
N. G. L.
F. F. L.
: 1/4" THK. MARINE PLYWOOD
HALLOW CORE LAMINATED
FLUSH DOOR
LOCATION
REQUIRED
: 3 SETS
D2
TYPE
: PVC DOOR
W/ LOUVERS
LOCATION
REQUIRED
: 5 SETS
5m
BUILDING SECTION A
0
SCALE: 1:100
2m
5m
1.59
SCALE: 1:100
2m
2.10
RIGHT-SIDE ELEVATION
5m
2.10
SCALE: 1:100
2m
1.17
0.60
0.545
0.70
FRONT ELEVATION
5m
5m
G. I. FLASHING
APEX OF STRUCTURE
5m
N. G. L.
4.00
G. I. GUTTER
0.93
APEX OF STRUCTURE
F. F. L.
1.16
1.48
CORRUGATED G. I.
SHEET ROOFING
CEILING LINE
W1
2.70
F. F. L.
TYPE
LOCATION
: BEDROOMS
REQUIRED
: 19 SETS
W2
TYPE
LOCATION
: TOILET
REQUIRED
: 2 SETS
7.26
STEEL PIPE
STAIR RAILING
1.15
7.26
SEE TRUSS
RAFTER DETAILS
SEE
DETAIL
CEILING LINE
1.22
1.16
APEX OF STRUCTURE
2ND F.F.L
BEDROOM 3
PTR'S BEDROOM
2ND F.F.L
3.20
S T R U C T U R E
2.40
3.20
E X I S T I N G
N. G. L.
REAR-SIDE ELEVATION
SCALE: 1:100
2m
VICENTE M. BAROT
CIVIL ENGINEER
DORMITORY 3 CAD FILE 160205 new.pln; A-2 FLOOR PLAN, ROOF PLAN, ELEVATIONS, SECTIONS & DETAILS; 100%; 2/5/2016 11:36 AM
5m
PRC NO.
47337
PTR NO.
0560219
PLACE:
TANJAY CITY
DATE:
1 - 11 - 2016
TIN
SEAL
BEDROOM 1
0.20
0.15
0.20
1.63
1.60
E X I S T I N G
F. F. L.
0.80
1.62
0.30
1m
2.5m
S T R U C T U R E
BATH
BATH
BEDROOM 2
F. F. L.
N. G. L.
BUILDING SECTION B
SCALE: 1:100
2m
5m
PROJECT TITLE:
SHEET CONTENTS:
APPROVED BY:
SHEET NO.
A-2
2
5
DATE: 2/5/2016