MEDICION DE LA PRODUCCION DE ACEITE EN EL EQUIPO DE PERFORACION Y EN LA BATERIA

VOLUMEN=AREA X ALTURA =2.12 X 7.5X3=47.7M3=47700LITROS/300CM=159 LITROS/CM.

EN EL EQUIPO

1BARRIL=159 LITROS..CONSTANTE DE PRESA=K=CTTE=FACTOR=159 LT/CM=1 BL/CM

7.5M
REGLA VERTICAL
DE MEDICION EN
CENTIMETROS

2.12M

CAPACIDAD
300 BLS=48M3
CONSTANTE DEL TANQUE
CTTE=K=1 BL/CM=159LT/CM

PLOMADA
CON CINTA
METRICA

EN LA BATERIA
DE PRODUCCION

3M

MEDIDA INICIAL=30CM

VOLUMEN PRODUCIDO DE ACEITE POR HORA


=46-30=16CMX159LT/CM=2544LT=2.544M3=16BLS
LA MEDICION EN EL EQUIPO SE REALIZA CADA HORA.. A CADA HORA SE MIDEN LOS NIVELES
Y SE OBTIENE EL VOLUMEN ACUMULADO HORA POR HORA HASTA COMPLETAR LAS 24 HORAS SI
LA PRODUCCION DEL POZO ES CONSTANTE ENTONCES EL ACUMULATIVO EN 24 HORAS
ES 16 BLS/HORA X 24 HORAS=384 BLS/DIA
VOLUMEN=AREA X ALTURA

4.5M

MEDIDA FINAL EN
UNA HORA=46CM

AREA=3.1416(4.5 X 4.5)/4=15.90 M2

VOLUMEN=15.90M2 X 5M=79.5M3=79 500 LT

VOLUMEN EN BLS=79 500 LT/159=500 BLS

5M

TANQUE DE
MEDICION
CAPACIDAD
500 BLS
CONSTANTE DEL TANQUE
CTTE=K=1 BL/CM

CONSTANTE DEL TANQUE=K=CTTE=FACTOR=500BLS/500CM= 1 BARRIL/CM


VOLUMEN DE ACEITE PRODUCIDO POR HORA
MEDIDA INICIAL=44CM
MEDIDA FINAL EN UNA HORA=60CM
PRODUCCION EN UNA HORA=60-44=16CM X 1 BL/CM=16 BLS/HORA
EN LA BATERIA EL BOMBERO MEDIDOR REALIZA LA MEDICION DE LOS NIVELES CADA HORA
OBTIENE EL ACUMULATIVO DE LAS 24 HORAS.SI LA PRODUCCION DEL POZO ES CONSTANTE
ENTONCES LA PRODUCCION MEDIDA DEL POZO(AFORO)
EN 24 HORAS=16 X 24=384 BARRILES/DIA