You are on page 1of 19

HOJA DE CALCULO DE CAR

DEL SUR

CLIENTE
REPRESENTANTE
DIRECCION
CONTACTO
ACONDICIONAR
FECHA

VARIABLE
VENTANAS

Mts/Anch

Mts/Alto

Unid

NORTE
NORTE
OESTE
OESTE
ESTE
ESTE
S.O - S.E.
S.O - S.E.
SUR
SUR
VIDRIO A LA SOMBRA
VIDRIO A LA SOMBRA
VIDRIO

0
0

0
0

0
0

TECHO

Mts

Mts

5.7

5.7

LOZA ( LAMINA)
DOS AGUAS
ESPACIO OCUPADO
PISO
PAREDES

Mts/Largo

Mts/Alto

Vent/M

ASOLEADA
A LA SOMBRA
DIVISION

11.7

2.5

1
0

2.5

PERSONAS

Unidades

OFICINA - CLASES
TRABAJO SUAVE
TRABAJO FUERTE

LUCES

Unidades

Wats

Lamparas o Focos

10

40

Otros
OTROS

Unidades

PC
FOTOCOPIADORAS
RETROPROYECTOR
CAON
CAFETERA
COCINETA
PUERTA

TONELADAS
Datos Basicos

Observaciones

Ejecutivo

MANUAL DE USO DE TABLA DE CA

1.-ESTA TABLA ESTA DISEADA SOLO PARA TEMPERATURA DE SAN SALVADOR A 32 G


2.-PARA SACAR CARGAS TERMICAS DE OTROS LUGARES Y TEMPERATURAS SE DEBE E
SUMANDO O RESTANDO SEGN SEA EL CASO.
3.-LA TABLA ESTA DISEADA SOLO PARA AREAS QUE NO TIENEN SUMINISTRO DE AIR
QUE TRABAJO PARA AREAS DE CIRCUITO CERRADO O RECIRCULACION SOLAMENTE.
4.-CUANDO SE HAYA CALCULADO LA CARGA DE VENTANAS POR RUMBO Y FACTOR, D
PLA LOS FACTORES POR TRATAMIENTO, QUE SON DEL 50% POR VIDRIO POLARIZADO
POR USO DE SOMBRA EXTERIOR O TOLDO O CUALQUIER OTRO SISTEMA DE SOMBRA
LA CARGA PREVIAMENTE CALCULA POR RUMBO Y FACTOR.
5.-CUANDO SE ENCUENTREN PAREDES DE METAL CON AISLAMIENTO DE POLIURETAN
SI FUERA LADRILLO DE SALTEX , ESTE FACTOR NO ESTA CONSIDERADO EN ESTA TABL
6.-EL FACTOR DE LOZA , EN CUANTO A TECHOS DEBE SER USADO CUANDO EL TECHO
LO QUE APARECE ENTRE PARENTESIS, LO QUE NO SIGNIFICA QUE ESE SEA EL FACTO
ALTO DE LA TABLA EN CUANTO A TECHOS, EN ESTE CASO EN ESPECIAL.
7.-PARED ASOLEADA.- ES TODA PARED EXTERIOR SIN IMPORTAR NI EL ANGULO, NI EL
SOLAR SOBRE ELLA , SE LE DEBE RESTAR EL AREA DE VENTANAS SI LAS HUBIESE.
8.-PARED A LA SOMBRA.- ES AQUELLAS QUE JAMAS LES DA EL SOL, QUE SOLO SIRVE
9.-DIVISION ES LA QUE ESTA HECHA DE TABLA ROCA O A FIN Y DIVIDE ENTRE CUART
10.-ESPACIO OCUPADO ES EL TECHO CUANDO ARRIBA HAY OTRO DEPARTAMENTO QU
POR TAL MOTIVO TRANSFIERE CALOR , SI ESTA ACONDICIONADO NO SE CONSIDERA.
11.-PISO, SE CONSIDERA CUANDO NO ESTA NIVEL TIERRA, SOLO CUANDO ES UN DEP
LA HABITACION INFERIOR NO HAY AIRE ACONDICIONADO, EN CASO CONTRARIO NO S
12.-PUERTA.- ES PUERTA O ESPACIOS ABIERTOS CONTINUAMENTE A AREAS NO ACON
DE CARGA TERMICA.

CALCULO DE CARGA TERM


CLIENTE
DEPARTAMENTO
DIRECCION
CONTACTO
ACONDICIONAR
FECHA

PROCURADURIA GENERAL DE LA REPUBLICA


COMPRAS
CENTRO DE GOBIERNO
LICDA. ERNESTINA CHAVEZ
CENTRO DE COMPUTO
9-May-11

VARIABLE

VENTANAS
NORTE

Mts/Anch

Mts/Alto

Unid

NORTE
OESTE
OESTE
ESTE
ESTE
S.O - S.E.
S.O - S.E.
SUR
SUR
VIDRIO A LA SOMBRA
VIDRIO A LA SOMBRA
VIDRIO

0
0
0
0
0
0
0
1
0
0
0

0
0
0
0
0
0
0
2.2
0
0
0

TECHO
LOZA
DOS AGUAS
ESPACIO OCUPADO
PISO

Mts

Mts

0
3
0
3

0
5.7
0
5.7

PAREDES
ASOLEADA
A LA SOMBRA
DIVISION

Mts/Largo

Mts/Alto

Vent/M

11.7
0
5
0

2.5
0
2.5
0

1
0
0
0

PERSONAS
OFICINA - CLASES
TRABAJO SUAVE
TRABAJO FUERTE

Unidades

LUCES
Lamparas o Focos
Otros

Unidades

Wats

10
0

40
0

OTROS
PC
FOTOCOPIADORAS
RETROPROYECTOR
CAON
CAFETERA
COCINETA
PUERTA

Unidades

4
0
0
0

2
0
0
1
0
0
0

0
0
0
0
0
0
0
1
0
0
0

TONELADAS
Datos Basicos

Observaciones

OTROS REFERIDO A:
CAPACIDAD EN WATT
DE LOS RACKS

NCIA DE CALOR ATRAVES DE PARED


S, TECHO NO EXCEDE LAS TRES TON
DE COMPUTO, LA CAPACIDAD DEL EQ
SE PARA LOGRAR LA MAYOR EFICIENC
ASI COMO PARA TENER UN MARGINA

Ejecutivo

E CALCULO DE CARGA TERMICA


TEMPERATURA
40
Tratamiento a Ventanas %
CORTINA
60%
POLARIZADO
50%
SOMBRA EXT.
30%
AISLAMIENTO DE
TECHO
Total/Mts

FACTOR

108
0
0
0
0
0
0
0
1
0
0
0

430
430
1680
1680
1070
1070
1730
1730
750
750
130
130
180

109

BTU

46,440.00
750.00
19,620.00

Cort/Pola

25%
60%
60%

50%
100%
50%
Sub-Total

Total/Mts

FACTOR

0
17.1
0
17.1

215
190
45
54

BTU

3,249.00
923.40

AISLAMIEN

90%
90%
100%
100%
Sub-Total

Total/Mts

FACTOR

28.25
0
12.5
0

100
30
86

BTU

500
700
1000

BTU

11,610.00
375.00
19,620.00
31,605.00
BTU

2,924.10
923.40
3,847.50
BTU

2,825.00
1,075.00
-

2,825.00
1,075.00
Sub-Total

FACTOR

70%

BTU

3,900.00
BTU

2,000
-

2,000
Sub-Total

Total

FACTOR

400

BTU

1,600

2,000
BTU

1,600

Sub-Total

FACTOR

BTU

500
2000
2000
2000
2000
2000
924
2000

BTU

1,000
2,000
-

1,000
2,000
-

Sub-Total

4.14

TOTAL

Autorizado

1,600

BTU/HORA

3,000

49,628.70

O DE TABLA DE CARGA TERMICA

E SAN SALVADOR A 32 GRADOS CENTRIGRADOS


EMPERATURAS SE DEBE EXTRAPOLAR PORCENTUALMENTE

NEN SUMINISTRO DE AIRE FRESCO DEL EXTERIOR, DE MODO


CULACION SOLAMENTE.
POR RUMBO Y FACTOR, DEBERA CONSIDERARSE QUE SE CONTEM
POR VIDRIO POLARIZADO, 60% POR USO DE CORTINAS Y
RO SISTEMA DE SOMBRA EXTERIOR EL FACTOR DE 30% MENOS

AMIENTO DE POLIURETANO U OTRO SIMILAR TOMESE COMO


NSIDERADO EN ESTA TABLA.
USADO CUANDO EL TECHO SEA DE LAMINA DE DOS AGUAS POR
A QUE ESE SEA EL FACTOR PERO SE USA PORQUE ES EL MAS
N ESPECIAL.
RTAR NI EL ANGULO, NI EL TIEMPO DE INCIDENCIA DE LA LUZ
ANAS SI LAS HUBIESE.
EL SOL, QUE SOLO SIRVEN DE DIVISION ENTRE DOS CUARTOS
N Y DIVIDE ENTRE CUARTO Y CUARTO.
OTRO DEPARTAMENTO QUE NO ESTA ACONDICIONADO Y QUE
ADO NO SE CONSIDERA.
OLO CUANDO ES UN DEPARTAMENTO EN PISO MEDIO, Y EN
N CASO CONTRARIO NO SE CONSIDERA.
MENTE A AREAS NO ACONDICIONADAS, POR TANTO TRASMISORAS

O DE CARGA TERMICA-COPIA CLIENTE

DE LA REPUBLICA

TEMP.LOCAL

Total/Mts

108

BTU

11,610.00

0
0
0
0
0
0
0
1
0
0
0
109

375.00
19,620.00

Sub-Total

Total/Mts

31,605.00
BTU

0
17.1
0
17.1

2,924.10
923.40
Sub-Total

Total/Mts

3,847.50
BTU

28.25
0
12.5
0

2,825.00
1,075.00
Sub-Total

3,900.00
2,000
-

Sub-Total
Total

2,000
BTU

400
0

1,600
Sub-Total

1,600
BTU

1,000
2,000
Sub-Total

3,000

4.14

BTU/HORA

Total

DE ACUERDO CON EL ESPACIO FISICO, LA TRASFERE


LOR ATRAVES DE PAREDES, LUMINARIAS RACKS, PERSONA
O EXCEDE LAS TRES TONELADAS PERO POR SER UN CENTRO
TO, LA CAPACIDAD DEL EQUIPO DEBE SOBRE DIMENSIONAR
GRAR LA MAYOR EFICIENCIA POSIBLE EN ESTE CASO A 5 TON
PARA TENER UN MARGINAL PARA OTROS EQUIPOS

Autorizado

49,629

a Ventanas %

49,628.70
45,952.50

HOJA DE CALCULO DE CARG


CLIENTE
REPRESENTANTE
DIRECCION
CONTACTO
ACONDICIONAR
FECHA

VARIABLE
VENTANAS

Mts/Anch

Mts/Alto

Unid

NORTE
NORTE
OESTE
OESTE
ESTE
ESTE
S.O - S.E.
S.O - S.E.
SUR
SUR
VIDRIO A LA SOMBRA
VIDRIO A LA SOMBRA
VIDRIO

TECHO

Mts

Mts

Mts/Largo

Mts/Alto

LOZA ( LAMINA)
DOS AGUAS
ESPACIO OCUPADO
PISO
PAREDES

ASOLEADA
A LA SOMBRA
DIVISION

PERSONAS

OFICINA - CLASES
TRABAJO SUAVE
TRABAJO FUERTE

Unidades

Vent/M

LUCES

Unidades

Wats

Lamparas o Focos
Otros
OTROS

Unidades

PC
FOTOCOPIADORAS
RETROPROYECTOR
CAON
CAFETERA
COCINETA

Total en Tonelaje
Datos Basicos

Observaciones

Ejecutivo

CULO DE CARGA TERMICA

Tratamiento a Ventanas %
Cortina
60%
Polarizado
50%
Sombra Ext.
30%

Total/Mts

BTU

Sub-Total

Total/Mts

BTU

Sub-Total
Total/Mts

BTU

Sub-Total

Sub-Total

Total

BTU

Sub-Total
BTU

Sub-Total

0.00

SAN SALV.

Autorizado

Total

You might also like