Professional Documents
Culture Documents
n
with ologi
a n e es
dge
Dimensional Flexibility
es
i
g
olo ge
h n a n ed
c
e
T with
Applications
Commercial Space : Office Buildings,
Theaters, Auditoriums
Institutional Space : Schools, Universities,
Libraries, Temples.
Industrial Manufacturing : Automotive,
Material Flexibility
edge tech offer a complete range of
construction materials, including galvanized
steel, pre-painted, painted, SS, aluminium,
etc.
Component Flexibility
Clean rooms
controls, dimensional flexibility - you name it edgetech has the expertise to deliver a
perfect solution.
The Panel
Standard 25 mm or 43 mm double
The Accessability
sheet or SS, are also an added edged feature. Each coil is pressure tested at 21 kg/cm under water.
The coil assembly is completed with carbon steel or copper header which is located within the coil
section on slide type arrangement for easy withdrawl & maintenance. AHUs with stack coils have
intermediate drain pan to collect the condensate of the top coil & drain the condensate through
PVC drop tubes to the main drain pan without flooding the lower coil.
applications.
* Humidification section with wet deck 100 mm or
200 mm / spray type with inlet vanes & mist
eliminator / steam humidifier & pan type
humidif ier for critical applications.
* Face & bypass / bypass damper section.
installations.
* Electric heater section for heating / humidity
control.
* Cross flow plate type, wheel type heat recovery
The Safety
Unlimited
Range of Air Handling Units
10
11
12
Air
Volume
(CFM)
Lenght
Width
Total Height
012H
1200
1320
850
015H
1500
1320
020H
2000
025H
030H
Filter
Face Area
(Sq.Ft)
Coil Face
Area (Sq.Ft)
2.25 MPS
2.5 MPS
2.75 MPS
850
4.0
2.4
1080
1200
1320
850
850
4.0
3.0
1350
1500
1370
850
850
4.0
4.0
1800
2000
1650
2200
2500
1450
1100
900
6.0
5.0
2250
2500
2750
3000
1550
1180
950
6.0
6.0
2700
3000
3300
040H
4000
1550
1470
950
8.0
8.0
3600
4000
4400
050H
5000
1700
1350
1200
12.0
10.0
4500
5000
5500
060H
6000
1850
1550
1200
12.0
12.0
5400
6000
6600
080H
8000
1950
1550
1520
16.0
16.0
7200
8000
8800
100H
10000
2100
1850
1520
20.0
20.0
9000
10000
11000
120H
12000
2225
2150
1520
24.0
24.0
10800
12000
13200
150H
15000
2580
2180
1850
30.0
30.0
13500
15000
16500
180H
18000
2790
2550
1850
40.0
36.0
16200
18000
19800
200H
20000
2790
2750
1850
40.0
40.0
18000
20000
22000
230H
23000
2790
2750
2150
48.0
46.0
20700
23000
25300
260H
26000
2925
2900
2250
54.0
52.0
23400
26000
28600
300H
30000
2925
3100
2450
63.0
60.0
27000
30000
33000
350H
35000
3085
3250
2650
70.0
70.0
31500
35000
38500
400H
40000
3185
3250
3230
80.0
80.0
36000
40000
44000
Dimensions (MM)
Please refer Horizontal Floor Mounted Unit-Dimension Chart for further information on dimensions.
Above mentioned length includes 50 mm thick pre filter, 4/6 rows deep coil and fan.
AT 8 MPS
AT 9 MPS
AT 10 MPS
7x7
228
259
0.0591
1001
1126
1251
1376
9x9
262
298
0.0781
1323
1489
1654
1820
10x10
289
331
0.0957
1622
1824
2027
2230
12x12
341
395
0.1347
2283
2569
2854
3139
15x15
404
471
0.1903
3226
3629
4032
4435
18x18
478
557
0.2662
4513
5077
5641
6206
Fan Model
AT 11 MPS
At 8 MPS
At 9 MPS
At 10 MPS
#160
204
204
0.0416
705
794
882
970
180
228
228
0.0520
881
991
1101
1212
200
256
256
0.0655
1111
1250
1389
1527
225
288
288
0.0829
1406
1582
1757
1933
250
322
322
0.1037
1758
1977
2197
2417
Model
ETU
At 11 MPS
280
360
360
0.1296
2197
2471
2746
3021
315
404
404
0.1632
2767
3113
3458
3804
4762
355
452
452
0.2043
3463
3896
4329
400
506
506
0.2560
4340
4883
5425
5968
450
568
568
0.3226
5469
6152
6836
7520
500
638
638
0.4070
6900
7762
8625
9487
560
714
714
0.5098
8642
9722
10802
11882
630
800
800
0.6400
10849
12205
13561
14917
710
898
898
0.8064
13669
15368
17087
18795
800
1006
1006
1.0120
17155
19299
21444
23558
900
1130
1130
1.2769
21645
24350
27056
29762
1000
1266
1266
1.6028
27168
30564
33960
37356
13
S1
S1
FILTER SIZES
A=610 X 610
B=610 X 305
C=305 X 305
(all dimension
in mm)
S1
External
Dimensions
(MM)
Model
ETU-
Width
(W)
Total
Height
(H)
Fan Section
S2
S3
Plain Filter
Section
Model
ETU
Combination
Filter Section
Pre (50 mm
thick) & Bag
(360 mm
thick) or Fine
(305 mm thick)
Chilled
Water Coil
Section 1-6
Rows Deep
Chilled
Water
Coil Section
8
Rows Deep
Hot Water
Coil Section
1-2
Rows Deep
Hot Water
Coil Section
4-6
Rows Deep
Electric
Heater
Section
Discharge
Plenum with
Fine Filter
Discharge
Plenum With Filter Quantity
A/B/C
Fine Filter &
HEPA Filter
012H
850
850
1320
870
440
450
880
200
012H
450
450
550
200
300
450
1000
1800
1/0/0
015H
850
850
1320
870
440
450
880
200
015H
450
450
550
200
300
450
1000
1800
1/0/0
020H
850
850
1370
920
440
450
880
200
020H
450
450
550
200
300
450
1000
1800
1/0/0
025H
1100
900
1450
1000
480
560
1000
200
025H
450
450
550
200
300
450
1450
2400
1/1/0
030H
1180
950
1550
1100
480
560
1000
200
030H
450
450
550
200
300
450
1450
2400
1/1/0
040H
1470
950
1550
1100
480
560
1000
200
040H
450
450
550
200
300
450
1450
2400
2/0/0
050H
1350
1200
1700
1250
480
560
1000
200
050H
450
450
550
200
300
450
1450
2400
2/2/0
060H
1550
1200
1850
1400
560
680
1200
200
060H
450
450
550
200
300
450
1450
2400
2/2/0
080H
1550
1520
1950
1500
560
680
1200
200
080H
450
450
550
200
300
450
1550
2600
4/0/0
100H
1850
1520
2100
1600
640
780
1380
200
100H
450
500
600
200
300
450
1550
2600
4/2/0
120H
2150
1520
2225
1725
640
780
1380
200
120H
450
500
600
200
300
450
1550
2600
6/0/0
150H
2180
1850
2580
2000
640
880
1580
200
150H
450
550
650
200
300
450
1550
2600
6/3/0
180H
2550
1850
2790
2240
640
1040
1840
200
180H
450
550
650
200
300
450
1750
2800
8/4/0
200H
2750
1850
2790
2240
840
1040
1840
200
200H
450
550
650
200
300
450
1750
2800
8/4/0
230H
2750
2150
2790
2240
840
1040
1840
200
230H
450
550
650
200
300
450
1750
2800
12 / 0 / 0
260H
2900
2250
2925
2375
840
1040
1840
200
260H
450
550
650
200
300
450
1750
2800
12 / 3 / 0
300H
3100
2450
2925
2375
840
1320
2400
200
300H
450
550
650
200
300
450
1750
2800
12 / 7 / 1
350H
3250
2650
3085
2535
840
1320
2400
200
350H
450
550
650
200
300
450
1750
2800
15 / 5 / 0
400H
3250
3250
3185
2635
840
1320
2400
200
400H
450
550
650
200
300
450
1750
2800
20 / 0 / 0
Note :
Standard models with 25 mm thick pannels are mentioned above, for 43 mm thick pannels add 45 mm extra to the width(W) and height(H) of the unit.
Total height (H) includes 100 mm deep base channel.
Symbol in the various sections above shows access door. If the same is required after HEPA filter for DOP test add 300 mm extra to the section.
For two tier AHUs and for other add on modules viz., wet deck section, spray section (single bank or double bank), heat recovery plate section or heat recovery
wheel section, sound attenuator section, empty section etc please contact our technical assistance department.
14
15
V-Series
Overall Dimension (MM)
(25 mm thick Prefilter, 1 - 6 RD
Coil & Fan)
Total
Depth
Width
Height
Air
Volume
(CFM)
Fan Model
KAT/FDA
Series
012V
1200
KAT 7/7/C
625
900
1140
015V
1500
KAT 9/9/C
625
1080
020V
2000
KAT 10/10/C
680
025V
2500
KAT 12/12/C
030V
3000
040V
Model
ETU
Fan Outlet
Velocity
(m/s)
40 MM WG
50 MM WG
9.59
1766/0.50/0.75
1865/0.54/0.75
2031/0.62/0.75
1190
9.07
1173/0.46/0.55
1312/0.55/0.75
1585/0.81/1.1
1030
1370
9.87
1027/0.57/0.75
1138/0.69/1.1
1286/0.83/1.1
750
1215
1440
8.76
894/0.70/1.1
1040/0.92/1.1
1205/1.21/1.5
KAT 9/9/S2
625
1555
1245
9.07
1220/0.99/1.1
1365/1.19/1.5
1649/1.73/2.2
4000
KAT 10/10/S2
680
1765
1350
9.87
1068/1.22/1.5
1184/1.49/2.2
1337/1.79/2.2
050V
5000
KAT 12/12/S2
750
1950
1480
8.76
930/1.51/2.2
1082/1.97/2.2
1253/2.6/3.7
060V1
6000
KAT 12/12/S2
750
2050
1565
10.52
927/1.91/2.2
1030/2.28/3.7
1176/2.85/3.7
060V2
6000
KAT 18/18/C
975
1775
1935
10.64
646/1.64/2.2
716/1.96/2.2
806/2.44/3.7
070V
7000
KAT 15/15/S2
840
2150
1810
8.68
801/2.01/2.2
902/2.49/3.7
1026/3.19/3.7
080V
8000
KAT 15/15/S2
860
2200
1845
9.93
801/2.36/3.7
896/2.88/3.7
1006/3.55/5.5
100V
10000
KAT 18/18/S2
1000
2550
1965
8.87
666/2.79/3.7
770/3.60/5.5
900/4.95/5.5
120V
12000
KAT 18/18/S2
1000
2800
2030
10.64
672/3.53/5.5
744/4.22/5.5
900/4.95/5.5
140V
14000
1100
2600
2500
10.24
630/1.97/2.2
700/2.35/3.7
785/2.89/5.5
160V
16000
1250
3000
2600
9.28
595/2.21/3.7
661/2.66/3.7
740/3.29/5.5
180V
18000
1250
3000
2700
10.44
602/2.61/3.7
666/3.11/5.5
739/3.75/5.5
# Above indicated data (RPM / BKW / Motor KW) corresponds to mean sea level.
# For Selection at other static pressure please contact our technical assistance department
Note :
Standard models with 25 mm thick panels are mentioned above.
For 8 rows deep coil add 100 mm extra to the depth of the unit.
Total height includes 100 mm deep base channel.
Units having fan model as S2 shall have two impellers mounted on common shaft driven by single motor.
For other add on modules viz., mixing chamber, ducted intake section, filter plenum, hot water coil section, electric heater section, pre & bag filter on
common frame, sound attenuator section, empty section etc please contact our technical assistance department.
16
C-Series
Air
Volume
(CFM)
Fan Model
KAT/FDA
Series
012C
1200
015C
Model
ETU
Width
Height
KAT 7/7/C
1180
800
540
1500
KAT 9/9/C
1180
930
020C
2000
KAT 10/10/C
1230
025C
2500
KAT 12/12/C
030C
3000
035C
Fan Outlet
Velocity
(m/s)
40 MM WG
50 MM WG
9.59
1766/0.50/0.75
1865/0.54/0.75
2031/0.62/0.75
550
9.07
1173/0.46/0.55
1312/0.55/0.75
1585/0.81/1.1
1030
610
9.87
1027/0.57/0.75
1138/0.69/1.1
1286/0.83/1.1
1300
1150
670
8.76
894/0.70/1.1
1040/0.92/1.1
1205/1.21/1.5
KAT 9/9/S2
950
1550
550
9.07
1220/0.99/1.1
1365/1.19/1.5
1649/1.73/2.2
3500
KAT 10/10/S2
1230
1580
610
8.64
1059/1.03/1.5
1201/1.27/1.5
1382/1.70/2.2
040C
4000
KAT 10/10/S2
1000
1765
610
9.87
1068/1.22/1.5
1184/1.49/2.2
1337/1.79/2.2
050C
5000
KAT 12/12/S2
1050
1925
670
8.76
930/1.51/2.2
1082/1.97/2.2
1253/2.6/3.7
060C
6000
KAT 12/12/S2
1050
2150
750
10.52
927/1.91/2.2
1030/2.28/3.7
1176/2.85/3.7
070C
7000
KAT 15/15/S2
1050
2160
800
8.68
801/2.01/2.2
902/2.49/3.7
1026/3.19/3.7
080C
8000
KAT 15/15/S2
1250
2250
900
9.93
801/2.36/3.7
896/2.88/5.5
1006/3.55/5.5
100C
10000
KAT 18/18/S2
1300
2550
980
8.87
666/2.79/3.7
770/3.60/5.5
900/4.95/5.5
120C
12000
KAT 18/18/S2
1300
3000
980
10.64
679/3.51/5.5
753/4.21/5.5
851/5.26/7.5
# Above indicated data (RPM / BKW / Motor KW) corresponds to mean sea level.
# For selection at other static pressure please contact our technical assistance department.
Note :
Standard models with 25 mm thick panels are mentioned above.
For 8 rows deep coil add 100 mm extra to the depth of the unit.
Units having fan model as S2 shall have two impellers mounted on common shaft driven by single motor.
For other add on modules viz., mixing chamber, ducted intake section, filter plenum, hot water coil section, electric heater section, pre & bag filter
on common frame, sound attenuator section, empty section etc please contact our technical assistance department.
17
Unit Model
ETU-012CD
ETU-015CD
1200
1500
ETU-020CD
ETU-030CD
2000
Static Pressure
25-30 mm wg
Pannel Thickness
25 mm
2.4
ETU-040CD
ETU-050CD
3000
4000
5000
10
Row Deep
4/6
Fan Model
9/9
9/9
10/10
9/9
10/10
12/12
No. of Fans
Watt
375
375
550
375x2
550x2
709x2
Motor Pole
RPM
950/925/900
950/925/900
1300/1200/1150
950/925/900
1300/1250/1150
900/715/510
Volt
220-240
Pre-Filter / 25 mm
Filter Media
Depth
960
960
960
960
960
1000
Width
1110
1110
1200
1650
1980
1925
Height
520
520
560
560
560
670
Note :
Above technical details refer to a static pressure of 25 - 28 mm WG.
Standard models with 25 mm thick panels are mentioned above.
For more details please contact our technical assistance department.
18
Air
Volume
(CFM)
Fan Model
KAT/FDA Series
012VU
1200
KAT 7/7/C
2.0
015VU
1500
KAT 9/9/C
020VU
2000
025VU
Model
ETU-
Filter Area
(Sq.Ft)
Filter Quantity
A/B/C
Lenght
Width
Total Height
0/1/0
900
620
720
4.0
1/0/0
900
720
820
KAT 10/10/C
4.0
1/0/0
1000
900
850
2500
KAT 12/12/C
4.0
1/0/0
1000
1000
850
030VU
3000
KAT 15/15/C
6.0
1/1/0
1200
1100
925
040VU
4000
KAT 15/15/C
6.0
1/1/0
1240
1100
925
8.0
2/0/0
1350
1290
1200
12.0
2/2/0
1500
1400
1300
16.0
4/0/0
1560
1400
1500
060VU
080VU
100VU
6000
8000
10000
FDA 450
FDA 500
FDA 560
120VU
12000
FDA 630
16.0
4/0/0
1700
1560
1600
160VU
16000
FDA 710
20.0
4/2/0
2000
1750
1800
200VU
20000
FDA 800
30.0
6/3/0
2140
2000
1950
250VU
25000
FDA 900
36.0
9/0/0
2300
2100
2200
300VU
30000
FDA 900
42.0
9/3/0
2300
2400
2200
350VU
35000
FDA 1000
48.0
12 / 0 / 0
2500
2700
2200
400VU
40000
FDA 1000
56.0
12 / 4 / 0
2500
2700
2500
Note :
Filter dimensions: A = 610 x 610; B = 610 x 305 & C = 305 x 305 (all in mm)
Total height includes 100 mm deep base channel
Optional accessories: bird screen, dampers, inlet cowl, louvers, ducted intake section, empty section, pre & fine filter on common frame, fine
filter plenum etc.
19
Single Skin
D u c ta b l e
U n i t s
Salient Features
n
Low height & compact design saves valuable space : ceiling suspended units are of low height, so they occupy
less space above the false ceiling, thereby, providing more shelf space.
Quiet operations : The units are fitted with low noise, DIDW forward curved centrifugal fans ideally suited for
offices, shops, restaurants, hotels, nursing homes, etc.
Variable speed saves energy : The units are fitted with 3 speed drive. One can adjust fan speed as per cooling load
conditions, thereby, saving energy & enhancing personal comfort.
Closed cell XPE thermal lining prevent sweating ensuring the safety of false ceiling.
Computer selected, high efficiency, cooling coils ensures effective heat transfer for years.
Powder coated GI construction virtually make the unit highly durable and rugged.
Technical Data
Unit Model
ETU-012SD
ETU-015SD
ETU-020SD
ETU-030SD
ETU-040SD
ETU-050SD
1200
1500
2000
3000
4000
5000
10
20-30 mm wg
Static Pressure
Casing Thickness
20 G GSS
Powder Coated
6 mm closed cell XPE
Internal Insulation
Coil Face Area (Sq. Ft.)
2.4
Rows Deep
4/6
9/9
10/10
9/9
10/10
12/12
Watt
375
375
550
375x2
550x2
709x2
Pole
RPM
950/925/900
950/925/900
1300/1200/1150
950/925/900
1300/1250/1150
900/715/510
Fan Diameter
No. of Fans
220 - 240
Volt
Filter Type / Thickness
Filter Media
HDPE Mesh
Overall Dimension of Units
Depth
695
695
750
695
750
850
Width
950
950
1050
1550
1775
1925
Height
460
460
520
460
520
575
BLOWER HOUSING
H
E
MOUNTING
HOLES 4 NOS
25mm collar
DUCT CONNECTION
DRAIN SOCKET
MOTOR
COIL TRAY
5
8"FLAIR NUT
AIR OUT
AIR FILTER
COOLING COIL
B
Model
ETU-
TR
Air
Volume
(CFM)
Motor
Rating
(HP)
Rows
Deep
12OFCH
1.0
400
1/15
180FCH
1.5
600
1/15
240FCH
2.0
800
1/12
300FCH
2.5
1000
1/12
360FCH
3.0
1200
1/3
Coil
Area
(Sq. Ft)
1.33
915
576
256
282
660
233
250
698
142
609
1.77
1118
576
256
282
863
233
250
902
142
812
2.43
1193
598
305
282
939
245
250
978
192
889
1.90
1005
598
305
282
749
245
250
789
192
698
242
914
3.00
1219
598
356
282
965
245
250
1003
2.25
1130
598
305
282
876
245
250
916
3.50
1371
653
356
282
1117
270
250
1155
242
1066
2.66
1118
653
356
282
865
270
250
902
242
812
Note :
Standard horizontal ceiling suspended FCU with 3 (or 4) rows deep coil having 10 mm outside dia. 27 G copper tubes. 12 mm thick rough filters.
13 (or 15)mm thick insulated drain pan and 12 FPI aluminium fins is given above.
Statically and dynamically balanced forward curved aluminium blowers with 3 speed fan motor (make: G.E / Eq.) 6 pole single phase 940 RPM.
For vertical floor mounted FCU and other add on modules viz., heating coil, auxillary tray, factory fitted ball valve set, two way or three way
valves, remote control etc., please contact our technical assistance department.
192
825