Refrigerant leakage
The heating performance values (kW) described in catalog are the values
obtained by operating at an outdoor temperature of 7 C and indoor
temperature of 20 C as set forth in the ISO Standards. As the heating
performance decreases as the outdoor temperature drops, if the outdoor
temperature is too low and the heating performance is insufficient, use other
heating appliances as well.
The sound values are the values (A scale) measured in a chamber such as an
anechoic chamber following the ISO Standards. In the actual installation
state, the value is normally larger than the values given in the catalog due to
the effect of surrounding noise and echo. Take this into consideration when
installing.
Take the following measures when installing the outdoor unit in snowy areas.
Snow prevention
Install a snow-prevention hood so that the snow does not obstruct the air
intake port or enter and freeze in the outdoor unit.
Snow piling
In areas with heavy snow fall, the piled snow could block the air intake
port. In this case, a frame that is 50cm or higher than the estimated snow
fall must be installed underneath the outdoor unit.
2014
2014
Installation
High Performance
Air-Conditioning
After the air-conditioner is used for several seasons, dirt will build up in
the air-conditioner causing the performance to drop. In addition to regular
servicing, we recommend the maintenance contract (charged for) by a
specialist.
Safety Precautions
Before use
DRAFT
Usage place
Do not install in places where combustible gas could leak or where there
are sparks.
Installation in a place where combustible gas could be generated, flow or
accumulate, or places containing carbon fibers could lead to fires.
ISO 14001
Mitsubishi Heavy
Industries-Haier (Quingdao)
Air-conditioners Co.,Ltd.
BIWAJIMA PLANT
Mitsubishi Heavy
Industries-Haier (Quingdao)
Air-conditioners Co.,Ltd.
New
50Hz
HB91-14KX03E-1
April 2014 R
Because of our policy of continuous improvement, we reserve right to make changes in all specifications without notice.
Edited in Japan
14KX03E-1
High Performance
Air-Conditioning
2014
Line Up
model
Contents
New
INSTALLATION FLEXIBILITY
KX Product Line is extended up to 60HP
with combination of 3 outdoor units
Introduction
4~15
Outdoor units
16~33
Indoor units
34~69
Control systems
70~79
8 0 . 81
82 . 83
84~87
Refresh series
8 8 . 89
Further information
90~93
3
R410A
NEW
Product Line Up
Standard model
10HP
KXZE1
Up to 48HP
17HP
8~36HP
6HP
8HP
11.2
38,200
9,630
14
47,800
12,040
15.5
52,900
13,330
22.4
76,400
19,260
kcal / h
Capacity
22HP
Model Code : kW
BTU / h
kcal / h
Capacity
BTU / h
kcal / h
24HP
26HP
10HP
12HP
14HP
16HP
17HP
18HP
32HP
FDC615KXZE1
FDC670KXZE1
FDC735KXZE1
FDC800KXZE1
FDC850KXZE1
FDC900KXZE1
10+12
12+12
12+14
14+14
14+16
16+16
28
33.5
40.0
45.0
47.5
50.0
56.0
95,500 114,300 136,500 153,600 162,100 170,600 191,100
24,080 28,810 34,400 38,700 40,900 43,000 48,160
36HP
28HP
30HP
32HP
34HP
36HP
38HP
44HP
46HP
48HP
50HP
52HP
54HP
56HP
58HP
14+14+14
40HP
18+18+18
FDC500KXZE1
FDC500KXZE1
FDC500KXZE1
60HP
NEW
Hi-COP model
FDC112KXES6
5HP
FDC140KXEN6
FDC140KXES6
FDC155KXES6
FDC224KXE6
10HP
FDC280KXE6
12HP
FDC335KXE6
20+20
1-phase 220-240V
3-phase 380-415V
46HP
FDC1250KXZE1 FDC1300KXZE1
14+14+16
14+16+16
48HP
50HP
52HP
FDC1350KXZE1
FDC1425KXZE1
FDC1450KXZE1
16+16+16
17+17+17
17+17+18
58HP
FDC1560KXZE1 FDC1620KXZE1
18+18+20
18+20+20
60HP
FDC1680KXZE1
20+20+20
10HP
12HP
FDC224KXZXE1
FDC280KXZXE1
FDC335KXZXE1
8+8
18HP
20HP
22HP
24HP
10+10
10+12
12+12
8HP
FDC1120KXZE1
8HP
FDC450KXZXE1
6HP
FDC155KXEN6
18+20
40HP
KXZXE1
16HP
4HP
18+18
54HP
FDC1500KXZE1
FDC112KXEN6
38HP
FDC1000KXZE1 FDC1060KXZE1
42HP
FDC1200KXZE1
FDC400KXZE1
FDC400KXZE1
FDC400KXZE1
model
20HP
61.5
67.0
73.5
80.0
85.0
90.0
95.0
100.0 106.0
112.0
209,900 228,700 250,800 273,000 290,100 307,100 324,200 341,300 361,800 382,300
52,890 57,600 63,200 68,800 73,100 77,400 81,700 86,000 91,100 96,300
42HP
Model Code : kW
30HP
FDC475KXZE1
FDC475KXZE1
5HP
BTU / h
28HP
17+17
4HP
20HP
FDC560KXZE1
26HP
FDC950KXZE1
16HP
FDC450KXZE1
24HP
FDC280KXZE1
FDC335KXZE1
<Outdoor units>
Capacity
18HP
FDC500KXZE1
14HP
FDC400KXZE1
22HP
34HP
Model Code : kW
FDC335KXZE1
FDC475KXZE1
KXZXE1
Up to 60HP
12HP
FDC280KXZE1
KX6
KXZE1
FDC735KXZXE1
8+8+10
28HP
30HP
32HP
34HP
36HP
10+10+10
10+10+12
10+12+12
12+12+12
R410A
<Indoor units>
10~60HP (KXZ)
DC Fan Motor
Type
Ceiling
Cassette
Duct
Connected
4way
FDT
4way Compact
(600 x 600)
FDTC
2way
FDTW
1way
FDTS
1way Compact
FDTQ
High
Static Pressure
FDU
Low/Middle
Static Pressure
FDUM
Low Static
Pressure
(thin)
FDUT
Compact &
Flexible
FDUH
5HP
140
6HP
160
Tetrahedral structure of
Heat Exchanger
8HP 10HP
224 280
Double tube
Wall Mounted
FDK
Ceiling Suspended
FDE
2way
FDFW
with casing
FDFL
without casing
FDFU
Discharge port
Total Efficiency
New Concentrated *
Winding Motor
Output
Floor
Standing
motor use.
FDU-F
Air flow M /h
3
SAF
SAF-DX
150
250
350
500
650
800
850
1000
1300
1800
Conventional Distributed
Winding Motor
Improved Seasonal
Efficiency rating
*applied for KXZE1:10/12/17/18/20HP & KXZXE1:8HP
Compressor Speed
R410A
Improved Heat-exchanger
[KX6]
[KXZ]
Vector control
Vector Control
Heat-
Heat-
Exchanger
Exchanger
Header
Power current
Operation period
Distributor
DC Fan Motor
Rotor(Squirrel Cage made of conductor)
Stator (coil)
Rotor(made of permanent magnet)
Serration
Stator (coil)
Room temperature
Room temperature
Set temperature
Set temperature
4~6HP (Micro)
Compact High Efficient
Heat Exchanger
Compressor
Compressor
Off
Off
Off
Constant level
Target low pressure was set at the constant level. When room
temperature got closer to set temperature, the compressor
shifted operation and repeated on-off operation continuously.
Heat Exchanger
DC Fan Motor
Compact & High efficiency
KX4
Micro
8~12HP (Micro)
Oil-equalizing pipe
Downsized accumulator
(kW)
PEAK CUT
Receiver in fan section
AM
8
3D-Scroll Compressor
(12HP)
PM
9
10
11
12
13
14
15
16
17
18
19
KX4
Micro
R410A
2. Design Flexibility
Indoor unit connection capacity
Capacity connection
HP
Micro model
150%
4~12
HP
KXZE1
10~60
130%
Max: 10m
Total length:
1000m
Max: 0.4m
Outdoor unit
Max: 5m
To the
first branch:
max 130m
Indoor unit
Indoor unit
Indoor unit
KXZE1
Height difference
*2
50m(outdoor unit above) 70m
40m(outdoor unit below)
Max height
difference
between
indoor units:
18m
Furthest
indoor unit:
160m
indoor unit piping from the first branch must be within 40m. (MAX85m)
1,400
Standard KXZE1
10
12
Numbers
22
24
24
Transportation in an
elevator made for six
persons
8~12HP (Micro)
850
Micro model
HP
HP
10
12
14
16
17
18
20
22
24
26
28
30
32
34
Numbers
24
29
34
39
41
43
48
53
58
63
69
73
78
80
HP
36
38
40
42
44
46
48
50
52
54
56
58
60
Numbers
80
80
80
80
80
80
80
80
80
80
80
80
80
Easy
transportation
800
Control Systems
KX series offer wide variation of control system and provide the best solution.
1350mm
Model
Type
10
RC-E5
RC-EX1A
RCN-T-36W-E etc.
SC-SL1N-E
SC-SL2NA-E
SC-SL4-AE
SC-SL4-BE
SC-WGWNA-A
SC-WGWNA-B
SC-BGWNA256-A
SC-BGWNA256-B
SC-BGWNA-A
SC-BGWNA-B
SC-LGWNA-A
1
1
1
16
64
128
128
128(64x2)
128(64x2)
256(128x2)
256(128x2)
128(64x2)
128(64x2)
96(48x2)
Electric power
calculation
1350mm
1350mm
Heating
-20C
Cooling
-15C
-20
+15.5C
-10
10
20
+46C
30
40
50
11
R410A
3. Serviceability
Easy Service
dip switch
Blower
compartment
Mechanical
compartment
Monitoring Function
KX series includes new feature to assist with servicing and trouble shooting.
Various data can be monitored through 3-digit or 6-digit display on the outdoor unit PCB.
Detailed fault diagnosis and operation history memory via
7-segment display.
4~6HP
You can select the following priority operation mode. (for whole system)
1. First units operation mode (by default setting)
2. Last units operation mode
<Majority operation mode>
3 Layer Construction
(KXZ)
8~60HP
Back-up Operation
Operation mode :
Cooling
In the event that one unit has a failure, the system will keep
operating with the other good units.
Operation mode :
Heating
Master setting :
Cooling
45
Operation mode :
Heating
45
56
56
71
56
56
71
28
Unit failed
Blue Fin
Due to application of blue coated fins for the heat exchanger of
new outdoor unit, corrosion resistance has been improved
compared to current models.
Blue
Fin
In the event that one compressor has a failure, the unit will
keep operating with the another good compressor.
Operation mode
cooling capacity
45 + 45 + 56 + 56 + 56 + 56
Total
314
Operation mode
heating capacity
71 + 71 + 28 + 28
Total
198
28
Operation mode :
Cooling
Master setting :
Cooling
Keeping
operation
Compressor
failed
Inverter
12
Operation mode :
FAN
Operation mode :
FAN
13
R410A
FDUM
FDUT
FDUM
Duct
Duct
Longer Duct
20mm less!!
Ceiling
2m
Depth: 520 500mm
case2
Setting No.
No.1
No.2
No.3
No.4
No.5
No.6
No.7
No.8
No.9 No.10
E.S.P.
10Pa
20Pa
30Pa
40Pa
50Pa
60Pa
70Pa
80Pa
90Pa 100Pa
RC-E5
E.S.P. button
A cross is visible
Cleaning
Previous Model
An outer
circle is visible
(71~140)
Hi
24
Fan speed
Access to control
32
10
0
37
Hi
Lo
4dB(A)
Down
30
20
22
Previous
Current
5dB(A)
Down
40
Serviceability
Access to control
28
Current Model
invisible
required
29
10
Cleaning
not required
1.5m
20
1m
[dB(A)]
Previous Model
FDU
Unit
1m
case1
2dB(A)
Down
30
1m
Previous
Current
1dB(A)
Down
30
Fan speed
26
Lo
Current Model
invisible
FDTS
FDU has the same E.S.P. control (refer to page 44) and
Transparent inspection window.
FDTW
14
For wireless remote control simply attach an additional panel with infrared receiver
on the right side of the main decorative panel.
RCN-TW-E
Selected
upper position
Max swing
range
Selected
lower position
* Wireless remote control and RCH-E3 is not applicable to the lndvidual flap
RCN-TS-E
15
R410A
Outdoor units
Heat pump systems 4, 5, 6hp (11.2kW~15.5kW)
Model No.
FDC112KXEN6
FDC140KXEN6
FDC155KXEN6
FDC112KXES6
FDC140KXES6
FDC155KXES6
Refrigerant piping
Outdoor unit (HP)
Gas pipe
Liquid pipe
Header pipe
DIS-22-1G/DIS-180-1G
HEAD6-180-1G
15.88
9.52
Blue
Fin
11.2kW (3phase)
14.0kW (3phase)
15.5kW (3phase)
Branch pipes
Dimensions
All measurements in mm.
These heat pump 2-pipe systems offer high performance VRF for
L3
L2
100
Intake
L4
Intake
Range of operation
Outdoor unit
50
+43C
Height difference
Cooling
20
Max height
difference between
indoor units: 15m
845
30
Indoor unit
Service
space
+15.5C
-15C
-20
970
-20C
110
195
279
50
55
50
-10
242
110
10
Heating
50
52
27
15
L1
L2
L3
L4
10
0
Furthest
indoor unit: 70m
outlet
40
L1
Terminal block
195
Indoor unit
36
40
51
50
II
II
Open
Open
500
300
Open
150
300
150
11.2
12.5
15.5
16.3
2.80
2.89
4.5-4.1
4.7-4.3
4.17
4.31
6.9-6.3
7.2-6.6
4.71
4.38
7.8-7.1
7.3-6.7
2.80
2.89
13.5-12.4
14.1-12.9
4.17
4.31
20.6-18.9
21.5-19.7
4.71
4.38
23.3-21.3
21.9-20.1
87
5.0
52/54
53/55
53/56
52/54
53/55
53/56
9.52(3/8")
15.88(5/8")
80~150
6
15
40
262
Mark
845x970x370
85
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
16
A
B
C
D
E
F
388
Item
Service valve connection (gas side)
Service valve connection (liquid line)
Pipe/cable draw-out port
Drain discharge port
Anchor bolt hole
Cable draw-out port
70
15.5
16.3
11.2
12.5
150
6HP
50
FDC155KXES6
5HP
3 Phase 380-415V, 50Hz
14.0
16.0
103
FDC140KXES6
4HP
55
FDC112KXES6
6HP
15
370
FDC155KXEN6
5HP
1 Phase 220-240V, 50Hz
14.0
16.0
410
FDC140KXEN6
4HP
200
60
38
Cooling
kW
Heating
A
Starting current
Cooling
Power
kW
Electrical characteristics consumption Heating
Cooling
Running
A
current
Heating
mm
Exterior dimensions
HxWxD
kg
Net weight
kg
Refrigerant charge
R410A
dB(A)
Cooling/Heating
Sound pressure level
Liquid line
mm(in)
Refrigerant piping size
Gas line
%
Capacity connection
Number of connectable indoor units
Nominal capacity
FDC112KXEN6
20
Model
580
60
40
Item
Nominal horse power
Power source
20
Specifications
190
60
40
15
50
VIEW A
Notes:
(1) It must not be surrounded by walls on the four sides.
(2) The unit must be fixed with anchor bolts. An anchor
bolt must not protrude more than 15mm.
(3) Where the unit is subject to strong winds, lay it in
such a direction that the blower outlet faces
perpendicularly to the dominant wind direction.
(4) Leave a 1m or larger space above the unit.
(5) A wall in front of the blower outlet must not exceed
the units height.
(6) The unit name plate is attached on the lower right
corner of the front panel.
17
R410A
Outdoor units
Heat pump systems 8, 10, 12hp (22.4kW~33.5kW)
Model No.
FDC224KXE6G
FDC280KXE6G
FDC335KXE6G
Refrigerant piping
Outdoor unit (HP)
Gas pipe
Blue
Fin
Liquid pipe
Gas pipe
Liquid pipe
8
Furthest indoor unit
=<90m
19.05
22.22
Branch pipes
10
12
22.22
28.58
9.52
Header pipe
12.7
28.58
12.7
DIS-22-1G/DIS-180-1G
HEAD6-180-1G
DIS-371-1G
Dimensions
All measurements in mm.
B
A
G
run of 160m.
II
II
Open
1500
300
Open
300
300
300
+43C
40
30
Cooling
20
Max height
difference
between
indoor units:
18m
+15.5C
-15C
-20
Furthest
indoor unit: 160m
-20C
1080
* The difference between the longest and the shortest indoor unit piping
51
54
14
35
55
-10
159
84
67
42
50
55
Heating
174
84
553
640(8.10HP)
634(12HP)
10
35
Indoor unit
Outlet
I
Open
84
L1
Service
space
159
194
Indoor unit
Intake
55
Indoor unit
L1
L2
L3
L4
L4
50
Height difference
50m(outdoor unit above)
40m(outdoor unit below)
1675
To the
first branch:
max 130m
Intake
Terminal block
Range of operation
Outdoor unit
20
L3
L2
43
60
120
69
51
69
These heat pump 2-pipe systems offer high performance VRF for
14
54
51
Cooling
kW
Heating
A
Starting current
Cooling
Power
kW
Electrical characteristics consumption Heating
Cooling
Running
A
current
Heating
HxWxD
mm
Exterior dimensions
kg
Net weight
R410A
kg
Refrigerant charge
Cooling/Heating
dB(A)
Sound pressure level
Liquid line
mm(in)
Refrigerant piping size
Gas line
%
Capacity connection
Number of connectable indoor units
Nominal capacity
FDC280KXE6G
FDC335KXE6G
8HP
10HP
3 Phase 380-415V, 50Hz
28.0
31.5
5
8.09
8.21
13.22-12.10
13.41-12.28
1675x1080x480
12HP
22.4
25.0
5.60
6.03
9.25-8.47
9.85-9.02
11.5
59/60
9.52(3/8")
19.05(3/4")
22
9.82
10.12
15.87-14.53
16.36-14.98
224
221
58/58
33.5
37.5
22.22(7/8")
50~150
24
61/61
12.7(1/2")
25.4(1") [22.22(7/8")]
30
701
461
421
80
Item
Service valve connection of the
attached connecting pipe (gas side)
B
C
D
E
24
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.
18
Mark
30
105
FDC224KXE6G
989
195
50
520
480
Model
19
39
Item
Nominal horse power
Power source
690
19
39
Specifications
195
141
241
321
361
FDC224KXE6G
FDC280KXE6G
FDC335KXE6G
19.05 (3/4")(Brazing)
22.22 (7/8")(Brazing)
25.4 (1")(Brazing)
Notes:
(1) It must not be surrounded by walls on the four sides.
(2) The unit must be fixed with anchor bolts. An anchor bolt
must not protrude more than 15mm.
(3) Where the unit is subject to strong winds, lay it in such
a direction that the blower outlet faces perpendicularly
to the dominant wind direction.
(4) Leave a 1m or larger space above the unit.
(5) A wall in front of the blower outlet must not exceed the
units height.
(6) The model name label is attached on the lower right
corner of the front.
(7) Connect the Service valve with local pipe by using the
pipe of the attachment.(Gas side only)
(8) Mark shows the connecting position of the local
pipe.(Gas side only)
19
R410A
Outdoor units
Heat pump systems 10, 12hp (28.0kW, 33.5kW)
Nominal Cooling Capacity
28.0kW
33.5kW
Model No.
FDC280KXZE1
FDC335KXZE1
Dimensions
All measurements in mm.
Blue
Fin
NEW
The KXZ heat pump 2-pipe systems offer high performance VRF for
applications that require either cooling only or heating only, ideal
for open plan areas.
Total length:
1000m
To the
first branch:
max 130m
Max: 0.4m
Outdoor unit
Max: 5m
Indoor unit
Indoor unit
Indoor unit
Range of operation
50
Height difference
*2
50m(outdoor unit above) 70m
40m(outdoor unit below)
+46C
40
30
Max height
difference
between
indoor units:
18m
Cooling
20
+15.5C
10
0
Furthest
indoor unit:
160m
Heating
-10
-15C
-20
*1 The difference between the longest and the shortest indoor unit piping
-20C
Specifications
Item
Nominal horse power
Power source
Model
FDC335KXZE1
10HP
12HP
280
22.22(Brazing)
9.52(Flare)
335
25.4(Brazing)
12.7(Flare)
Installation example
88(or 100)
50 (right . left . front), long hole 40 x 80 (under side)
M10 x 4 places
45 x 3 places
20 x 10 places
9.52(Flare)
230 x 60
33.5
37.5
8.96
9.04
14.6
14.8
1690x1350x720
272
11.0
55/57
9.52(3/8")
22.22(7/8")
500
Open
10(30)
10(30)
61/58
12.7(1/2")
25.4(1") [22.22(7/8")]
29
100
100
10(30)
Open
1500
Open
No limit
No limit
1000
No limit
No limit
Open
Installation example
Wall height
H3
L3
L2
L5
L6
L1 (Unit front side)
50~130
24
L1
L2
L3
L4
H1
H2
H3
H4
8
7.24
7.28
11.9
12.0
Dimensions
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.
20
Content
Refrigerant gas piping connection pipe
Refrigerant liquid piping connection pipe
Refrigerant piping exit hole
Power supply entry hole
Anchor bolt hole
Drain waste water hose hole
Drain hole
Refrigerant oil equalization piping connection pipe
Carrying in or hole for hanging
Wall height
H2
L4
Wall height
H4
Cooling
kW
Nominal capacity
Heating
A
Starting current
Cooling
Power
kW
Electrical characteristics consumption Heating
Cooling
Running
A
current
Heating
HxWxD
mm
Exterior dimensions
kg
Net weight
R410A
kg
Refrigerant charge
Cooling/Heating
dB(A)
Sound pressure level
Liquid line
mm(in)
Refrigerant piping size
Gas line
%
Capacity connection
Number of connectable indoor units
FDC280KXZE1
Mark
A
B
C
D
F
G
H
K
L
Wall height
H2
Max: 10m
Dimensions
L1
500
Open
L2
10
200
L3
100
300
L4
10
Open
L5
400
L6
400
H1
1500
No limit
H2
No limit
No limit
H3
1000
No limit
H4
No limit
No limit
21
R410A
Outdoor units
Heat pump systems 14, 16, 17, 18, 20hp (40.0kW~56.0kW)
Nominal Cooling Capacity
40.0kW
45.0kW
47.5kW
50.0kW
56.0kW
Model No.
FDC400KXZE1
FDC450KXZE1
FDC475KXZE1
FDC500KXZE1
FDC560KXZE1
Dimensions
All measurements in mm.
Blue
Fin
NEW
The KXZ heat pump 2-pipe systems offer high performance VRF for
applications that require either cooling only or heating only, ideal
for open plan areas.
Max: 10m
Total length:
1000m
To the
first branch:
max 130m
Max: 0.4m
Outdoor unit
Max: 5m
Indoor unit
Indoor unit
Indoor unit
Range of operation
50
Height difference
*2
50m(outdoor unit above) 70m
40m(outdoor unit below)
+46C
40
30
Max height
difference
between
indoor units:
18m
Cooling
20
+15.5C
10
0
Furthest
indoor unit:
160m
Heating
-10
-15C
-20
*1 The difference between the longest and the shortest indoor unit piping
from the first branch must be within 40m. (MAX85m)
*2 Height difference up to 100m is possible with High Head series.
Please refer to page 84.
-20C
Specifications
Item
Nominal horse power
Power source
Model
FDC400KXZE1
FDC450KXZE1
FDC475KXZE1
FDC500KXZE1
FDC560KXZE1
14HP
16HP
17HP
3 Phase 380-415V, 50Hz
47.5
53.0
8
13.98
13.00
22.6
21.0
2048x1350x720
18HP
20HP
40.0
Cooling
kW
45.0
Heating
A
Starting current
10.96
Cooling
Power
kW
10.69
Electrical characteristics consumption Heating
17.5
Cooling
Running
A
current
17.5
Heating
HxWxD
mm
Exterior dimensions
317
kg
Net weight
R410A
kg
Refrigerant charge
Cooling/Heating
60/62
dB(A)
Sound pressure level
Liquid line
mm(in)
Refrigerant piping size
25.4(1") [28.58(1 1/8")]
Gas line
%
Capacity connection
34
Number of connectable indoor units
Nominal capacity
45.0
50.0
13.98
12.50
22.4
20.4
50.0
56.0
56.0
63.0
13.97
13.49
22.6
21.8
16.62
15.95
26.9
25.8
Mark
A
B
C
D
F
G
H
K
L
Content
Refrigerant gas piping connection pipe
Refrigerant liquid piping connection pipe
Refrigerant piping exit hole
Power supply entry hole
Anchor bolt hole
Drain waste water hose hole
Drain hole
Refrigerant oil equalization piping connection pipe
Carrying in or hole for hanging
400
25.4(Brazing)
12.7(Flare)
88(or 100)
50 (right . left . front), long hole 40 x 80 (under side)
M10 x 4 places
45 x 3 places
20 x 10 places
9.52(Flare)
230 x 60
Installation example
Dimensions
L1
L2
L3
L4
H1
H2
H3
H4
500
Open
10(30)
10(30)
100
100
10(30)
Open
1500
Open
No limit
No limit
1000
No limit
No limit
Open
370
61/62
39
11.5
61/61
12.7(1/2")
28.58(1 1/8")
50~130
41
61/62
64/66
43
48
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
22
23
R410A
Outdoor units
Heat pump combination systems
22, 24hp (61.5kW, 67.0kW)
Model No.
FDC615KXZE1 (FDC280+FDC335)
FDC670KXZE1 (FDC335+FDC335)
Dimensions
All measurements in mm.
Blue
Fin
NEW
The KXZ heat pump 2-pipe systems offer high performance VRF for
applications that require either cooling only or heating only, ideal
for open plan areas.
Max: 10m
Total length:
1000m
To the
first branch:
max 130m
Max: 0.4m
Outdoor unit
Max: 5m
Indoor unit
Indoor unit
Indoor unit
Range of operation
50
Height difference
*2
50m(outdoor unit above) 70m
40m(outdoor unit below)
+46C
40
30
Max height
difference
between
indoor units:
18m
Cooling
20
+15.5C
10
0
Furthest
indoor unit:
160m
Heating
-10
-15C
-20
*1 The difference between the longest and the shortest indoor unit piping
-20C
Specifications
Item
Model
Combination (FDC)
Nominal horse power
Power source
Cooling
kW
Heating
A
Starting current
Cooling
Power
kW
Electrical characteristics consumption Heating
Cooling
Running
A
current
Heating
HxWxD
mm
Exterior dimensions
kg
Net weight
R410A
kg
Refrigerant charge
Liquid line
mm(in)
Refrigerant piping size
Gas line
%
Capacity connection
Number of connectable indoor units
Nominal capacity
FDC615KXZE1
FDC670KXZE1
280KXZE1
335KXZE1
22HP
335KXZE1
335KXZE1
24HP
3 Phase 380-415V, 50Hz
61.5
69.0
67.0
75.0
16
16.20
16.32
26.5
26.8
17.92
18.08
29.2
29.6
1690x2700x720
544
11.0x2
12.7(1/2")
28.58(1 1/8")
50~130
53
Mark
A
B
C
D
F
G
H
K
L
Content
Refrigerant gas piping connection pipe
Refrigerant liquid piping connection pipe
Refrigerant piping exit hole
Power supply entry hole
Anchor bolt hole
Drain waste water hose hole
Drain hole
Refrigerant oil equalization piping connection pipe
Carrying in or hole for hanging
280
335
22.22(Brazing)
25.4(Brazing)
Dimensions
9.52(Flare)
12.7(Flare)
L1
L2
L3
L4
H1
H2
H3
H4
500
Open
10(30)
10(30)
88(or 100)
50 (right . left . front), long hole 40 x 80 (under side)
M10 x 4 places
45 x 3 places
20 x 10 places
9.52(Flare)
230 x 60
Installation example
100
100
10(30)
Open
1500
Open
No limit
No limit
1000
No limit
No limit
Open
58
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
24
25
R410A
Outdoor units
Heat pump combination systems
26, 28, 30, 32, 34, 36, 38, 40hp (73.5kW~112.0kW)
Nominal Cooling Capacity
73.5kW
80.0kW
85.0kW
90.0kW
95.0kW
100.0kW
106.0kW
112.0kW
Model No.
FDC735KXZE1 (FDC335+FDC400)
FDC800KXZE1 (FDC400+FDC400)
FDC850KXZE1 (FDC400+FDC450)
FDC900KXZE1 (FDC450+FDC450)
FDC950KXZE1 (FDC475+FDC475)
FDC1000KXZE1 (FDC500+FDC500)
FDC1060KXZE1 (FDC500+FDC560)
FDC1120KXZE1 (FDC560+FDC560)
Dimensions
All measurements in mm.
Blue
Fin
NEW
The KXZ heat pump 2-pipe systems offer high performance VRF for applications that
require either cooling only or heating only, ideal for open plan areas.
Total length:
1000m
To the
first branch:
max 130m
Max: 0.4m
Outdoor unit
50
Height difference
*2
50m(outdoor unit above) 70m
40m(outdoor unit below)
Max: 5m
Indoor unit
Indoor unit
+46C
40
30
Max height
difference
between
indoor units:
18m
Indoor unit
Range of operation
20
Cooling
+15.5C
10
0
Furthest
indoor unit:
160m
Heating
-10
-15C
-20
*1 The difference between the longest and the shortest indoor unit piping
-20C
Specifications
Item
Model
Combination (FDC)
Nominal horse power
Power source
Cooling
kW
Heating
A
Starting current
Cooling
Power
kW
Electrical characteristics consumption Heating
Cooling
Running
A
current
Heating
HxWxD
mm
Exterior dimensions
kg
Net weight
R410A
kg
Refrigerant charge
Liquid line
mm(in)
Refrigerant piping size
Gas line
%
Capacity connection
Number of connectable indoor units
Nominal capacity
400KXZE1
400KXZE1
28HP
400KXZE1
450KXZE1
30HP
73.5
82.5
80.0
90.0
85.0
95.0
19.92
19.73
32.1
32.3
21.92
21.38
35.0
35.0
24.94
23.19
39.9
37.9
589
11.0+11.5
63
450KXZE1
475KXZE1
450KXZE1
475KXZE1
32HP
34HP
3 Phase 380-415V, 50Hz
90.0
95.0
100.0
106.0
16
27.96
27.96
25.00
26.00
44.8
45.2
40.8
42.0
2048x2700x720
634
500KXZE1
500KXZE1
36HP
500KXZE1
560KXZE1
38HP
560KXZE1
560KXZE1
40HP
100.0
112.0
106.0
119.0
112.0
126.0
27.94
26.98
45.2
43.6
30.59
29.44
49.5
47.6
33.24
31.90
53.8
51.6
Mark
A
B
C
D
F
G
H
K
L
Content
Refrigerant gas piping connection pipe
Refrigerant liquid piping connection pipe
Refrigerant piping exit hole
Power supply entry hole
Anchor bolt hole
Drain waste water hose hole
Drain hole
Refrigerant oil equalization piping connection pipe
Carrying in or hole for hanging
400
25.4(Brazing)
28.58(Brazing)
12.7(Flare)
88(or 100)
50 (right . left . front), long hole 40 x 80 (under side)
M10 x 4 places
45 x 3 places
20 x 10 places
9.52(Flare)
230 x 60
Installation example
Dimensions
L1
L2
L3
L4
H1
H2
H3
H4
500
Open
10(30)
10(30)
100
100
10(30)
Open
1500
Open
No limit
No limit
1000
No limit
No limit
Open
740
11.5x2
69
15.88(5/8")
31.75(1 1/4") [34.92(1 3/8")]
50~130
73
78
19.05(3/4")
38.1(1 1/2") [34.92(1 3/8")]
80
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.
26
27
R410A
Outdoor units
Heat pump combination systems
42, 44, 46, 48, 50, 52, 54, 56, 58, 60hp (120.0kW~168.0kW)
Nominal Cooling Capacity
Model No.
120.0kW
FDC1200KXZE1 (FDC400+FDC400+FDC400)
125.0kW
FDC1250KXZE1 (FDC400+FDC400+FDC450)
130.0kW
FDC1300KXZE1 (FDC400+FDC450+FDC450)
135.0kW
FDC1350KXZE1 (FDC450+FDC450+FDC450)
142.5kW
FDC1425KXZE1 (FDC475+FDC475+FDC475)
145.0kW
FDC1450KXZE1 (FDC475+FDC475+FDC500)
150.0kW
FDC1500KXZE1 (FDC500+FDC500+FDC500)
156.0kW
FDC1560KXZE1 (FDC500+FDC500+FDC560)
162.0kW
FDC1620KXZE1 (FDC500+FDC560+FDC560)
168.0kW
FDC1680KXZE1 (FDC560+FDC560+FDC560)
Dimensions
All measurements in mm.
Blue
Fin
NEW
The KXZ heat pump 2-pipe systems offer high performance VRF for applications that
require either cooling only or heating only, ideal for open plan areas.
Total length:
1000m
To the
first branch:
max 130m
Max: 0.4m
Outdoor unit
Max: 5m
Indoor unit
50
Height difference
*2
50m(outdoor unit above) 70m
40m(outdoor unit below)
Indoor unit
Range of operation
Indoor unit
+46C
40
30
Max height
difference
between
indoor units:
18m
20
Cooling
+15.5C
10
0
Furthest
indoor unit:
160m
Heating
-10
-15C
-20
*1 The difference between the longest and the shortest indoor unit piping
-20C
Specifications
Item
Combination (FDC)
Nominal horse power
Power source
Model FDC1200KXZE1
400KXZE1
400KXZE1
400KXZE1
42HP
Cooling
kW
Heating
A
Starting current
Cooling
Power
kW
Electrical characteristics consumption Heating
Cooling
Running
A
current
Heating
HxWxD
mm
Exterior dimensions
kg
Net weight
R410A
kg
Refrigerant charge
Liquid line
mm(in)
Refrigerant piping size
Gas line
%
Capacity connection
Number of connectable indoor units
Nominal capacity
120.0
135.0
125.0
140.0
130.0
145.0
32.88
32.07
52.5
52.5
35.90
33.88
57.4
55.4
38.92
35.69
62.3
58.3
951
Mark
A
B
C
D
F
G
H
K
L
Content
Refrigerant gas piping connection pipe
Refrigerant liquid piping connection pipe
Refrigerant piping exit hole
Power supply entry hole
Anchor bolt hole
Drain waste water hose hole
Drain hole
Refrigerant oil equalization piping connection pipe
Carrying in or hole for hanging
400
25.4(Brazing)
28.58(Brazing)
12.7(Flare)
88(or 100)
50 (right . left . front), long hole 40 x 80 (under side)
M10 x 4 places
45 x 3 places
20 x 10 places
9.52(Flare)
230 x 60
Installation example
Dimensions
L1
L2
L3
L4
H1
H2
H3
H4
500
Open
10(30)
10(30)
100
100
10(30)
Open
1500
Open
No limit
No limit
1000
No limit
No limit
Open
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.
28
29
R410A
refrigerant piping
Installation of Interconnecting Pipework
Mitsubishi KXZ equipment is manufactured to
the highest standards of quality and reliability.
It is imperative the method of installation and
the materials used are also to high standards,
to ensure trouble free operation and long term
reliability.
The interconnecting pipework must be installed
by a competent and trained engineer.
Refrigeration quality copper tube must be used,
soft copper coils or half-hard straight lengths.
The refrigeration quality tube must be soft
drawn seamless high grade copper pipe. The
copper tube must be selected taking into
account the higher operating pressures of
R410A refrigerant, and that high pressures will
occur throughout the system because of the
reverse cycle operation. All pipework material
used should be EN12735 European standard.
refrigerant piping
Main (Outdoor unit side branching pipe Indoor unit side first branching pipe)
If the longest distance (measured between the outdoor unit and the farthest indoor unit)
is 90m or longer (actual length), please change the main pipe size according to the table
below.
Main pipe size (normal)
Gas pipe
Liquid pipe
Outdoor
unit
280
335
400
450
475
500
560
615
670
735
800
850
900
950
1000
1060
1120
1200
1250
1300
1350
1425
1450
1500
1560
1620
1680
22.22 t 1.0
25.4 (22.22) t 1.0
25.4 (28.58) t 1.0
28.58 t 1.0
31.8 t 1.1
(34.92 t 1.2)
9.52 t 0.8
12.7 t 0.8
31.8 t 1.1
(28.58 t 1.0)
12.7 t 0.8
mm
inch
12.7
1/2"
9.52
15.88
19.05
22.22
25.4
15.88 t 1.0
15.88 t 1.0
19.05 t 1.0
Header pipe
DIS-22-1G/DIS-180-1G
HEAD6-180-1G
Combination outdoor unit manifold
5/8"
3/4"
7/8"
1"
mm
inch
31.8
11/4"
38.1
11/2"
50.8
2"
28.58 11/8"
DIS-371-1G/DIS-540-3
DOS-2A-3
DOS-3A-3
34.92 13/8"
44.5
38.1 t 1.35
(34.92 t 1.2)
38.1 t 1.35
(34.92 t 1.2)
3/8"
Branch pipes
Horizontally
13/4"
Floor
No
22.22 t 1.0
19.05 t 1.0
Good
Good
Vertically
Floor
No
Floor
Floor
HEAD8-371-1G
Piping arrangement using
branch pipe kits
Oil equalisation
pipe
Outdoor unit branch
piping set (DOS-2A-3)
Liquid pipe
90
90
56
56
36
36
36
36
Gas pipe
112
112
90
90
90
140
Outdoor unit
Branch piping set
For two units (for 615~1120) DOS-2A-3
For three units (for 1200~1680) DOS-3A-3
HEAD8-540-3
56
30
56
36
36
36
112
112
112
112
140
140
112
90
90
90
140
140
140
Total capacity of
indoor units
~179
180~370
371~539
540~
Header set
Model
HEAD4-22-1G
HEAD6-180-1G
HEAD8-371-2
HEAD8-540-3
Branches
Max 4 branches
Max 6 branches
Max 8 branches
Max 8 branches
31
R410A
KXZ new design includes greatly simplified wiring requirements utilising a polarity-free two wire control loop connecting the indoor units.
Power wiring
Cables can be laid through the front, right, left or bottom of the outdoor unit casing.
Separate power supplies should be used for the outdoor unit (3/phase) and the indoor units (1/phase).
Only control wiring is connected from outdoor to indoor unit.
Circuit breaker
for cabling
Outdoor unit
Grounding
wire
[2 cores]
A
B
1.25mm2
YES
NO
0.75mm2
YES
YES
A1
B1
A1
A1
B1
B1
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
A1B1 A2B2
A1B1 A2B2
A1B1 A2B2
A1B1 A2B2
Indoor unit
Indoor unit
A
B
A
B
Indoor unit
Indoor unit
A
B
A
B
Signal line
Refrigerant pipe
(b) The signal wires can also be connected using the method shown below.
Indoor unit
(3) The signal lines can also be connected using the method shown below.
Important
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
CAUTION
If the earth leakage breaker is exclusively for ground fault protection, then you will need to install a circuit breaker for wiring work.
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Electrical
component box
Outdoor unit
Indoor unit
32
Network connector
(a) The maximum number of indoor units that can be connected in a system is 128 and it is possible to configure
outdoor units and/or indoor units as an outdoor or indoor unit group connected with each other with two wires.
Circuit breaker
for cabling
Earth leakage breaker
Length (m)
100 to 200
To 300
To 400
To 600
Wire size
0.5mm2 x 2 core
0.75mm2 x 2 core
1.25mm2 x 2 core
2.0mm2 x 2 core
Remote control
A
Indoor unit
A
Indoor unit
Indoor unit
33
R410A
Indoor units
Ceiling Cassette -4wayFDT
Model No.
FDT28KXE6F
FDT36KXE6F
FDT45KXE6F
FDT56KXE6F
FDT71KXE6F
Dimensions
All measurements in mm.
RC-E5
RCH-E3
Wireless
FDT90KXE6F
FDT112KXE6F
FDT140KXE6F
FDT160KXE6F
RCN-T-36W-E
KX4
270mm
365mm
246
298
mm
KX4
mm
9%
FDT28~71
FDT112~160
reduction!!
KX6
18%
reduction!!
Selection of flap
position is possible.
Individual flaps can
be set at different
angles.
Upper
position
Movable
range
Lower
position
Specifications
Item
Model FDT28KXE6F
Nominal cooling capacity kW
2.8
Nominal heating capacity kW
3.2
Power source
Cooling
Power
consumption Heating kW
Sound power level dB(A)
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
Net weight
kg
Air flow
m3/min
Outside air intake
Panel
Air filter, Qty
Remote control(option)
Liquid line:6.35(1/4")
Installation data
Refrigerant piping size mm(in) Gas line:9.52(3/8")
FDT36KXE6F
FDT45KXE6F
FDT56KXE6F
3.6
4.0
4.5
5.0
5.6
6.3
FDT71KXE6F
7.1
8.0
1 Phase 220-240V, 50Hz
0.04-0.04
0.08-0.08
0.04-0.04
0.08-0.08
60
64
0.03-0.03
0.03-0.03
53
Hi:33 Me:31 Lo:30
Unit:246x840x840 Panel:35x950x950
Unit:22 Panel:5.5
9.0
10.0
11.2
12.5
16.0
18.0
0.15-0.15
0.15-0.15
65
Hi:40 Me:37 Lo:35
Unit:298x840x840 Panel:35x950x950
Unit:24 Panel:5.5
14.0
16.0
Unit:27 Panel:5.5
Hi:27 Me:24 Lo:20
Possible
T-PSA-3BW-E
Pocket Plastic net x1 (Washable)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-T-36W-E
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDT28/36/45 37dB(A), FDT56 39dB(A), FDT71 46dB(A), FDT90/112/140/160 51dB(A). Air flow: FDT28/36/45/56 20m3/min, FDT71 28m3/min, FDT90/112/140/160 37m3/min.
34
35
R410A
Dimensions
All measurements in mm.
Model No.
FDTC15KXE6F
FDTC22KXE6F
FDTC28KXE6F
FDTC36KXE6F
FDTC45KXE6F
FDTC56KXE6F
Wireless
RC-EX1A
(1) Can not be connected to some KX outdoor units. Please consult your dealer for further details.
(2) Regarding pipe length (150m or more is required) and temperature condition (lowest 10C) in the cooling operation etc. , please refer to our technical manual.
(dB)40
(dB)40
(dB)40
39
dB
35
35
300mm
OA Spacer
25
30
25
dB
25
dB
KX6
(Cooling)
KX6
(Heating)
20
Ceiling OA
surface
Panel
OA
Joint Duct
32
32
dB
dB
30
dB
32
dB
25
30
3~8dB
Down
31
dB
34
dB
25
20
20
KX4
KX6
(Cooling/Heating) (Cooling)
FDTC15
36
dB
34
34
dB
dB
34
dB
35
2dB
Down
KX6
(Heating)
KX4
(Cooling/Heating)
KX6
(Cooling)
KX6
(Heating)
FDTC36/45/56
FDTC22/28
Upper
position
Movable
range
FDTC15KXE6F,
22KXE6F,
28KXE6F
Lower
position
Specifications
Item
Model
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound power level dB(A)
Sound pressure Cooling
dB(A)
level
Heating
FDTC15KXE6F
FDTC22KXE6F
1.5
1.7
2.2
2.5
0.02-0.02
0.02-0.02
Hi:32 Me:28 Lo:25
Hi:32 Me:28 Lo:25
Installation data
Refrigerant piping size mm(in)
FDTC45KXE6F
FDTC56KXE6F
4.5
5.0
5.6
6.3
0.05-0.05
0.05-0.05
60
Hi:40 Me:37 Lo:31
Hi:45 Me:39 Lo:31
Hi:40 Me:37 Lo:34
Hi:45 Me:39 Lo:34
Unit:248x570x570 Panel:35x700x700
kg
Cooling
Air flow
m3/min
Heating
Outside air intake
Panel
Air filter, Qty
Remote control(option)
FDTC36KXE6F
2.8
3.6
3.2
4.0
1 Phase 220-240V, 50Hz
0.03-0.03
0.03-0.03
56
58
Hi:35 Me:33 Lo:30
Hi:38 Me:36 Lo:31
Hi:35 Me:33 Lo:32
Hi:38 Me:36 Lo:34
Exterior dimensions
mm
HxWxD
Net weight
FDTC28KXE6F
Unit:14 Panel:3.5
Hi:9.5 Me:8.5 Lo:7
Hi:10 Me:9 Lo:7
Hi:9.5 Me:8.5 Lo:8
Hi:10 Me:9 Lo:8
Possible with OA Spacer TC-OAS-E & Joint Duct TC-OAD-E
TC-PSA-25W-E
Pocket Plastic net x1 (Washable)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-TC-24W-ER
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
Unit:15 Panel:3.5
Hi:11 Me:9 Lo:7
Hi:11 Me:9 Lo:8
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
36
Powerful-Hi can be selected. Sound pressure level: FDTC15 34dB(A), FDTC22/28 44dB(A), FDTC36 46dB(A), FDTC45 48dB(A), FDTC56 49dB(A). Air flow: FDTC15 8m 3/min, FDTC22/28 12m3/min, FDTC36 13m3/min, FDTC45
15m3/min, FDTC56 16m3/min.
37
R410A
Dimensions
All measurements in mm.
Wired
650
102
Wireless
FDTW90KXE6F
FDTW112KXE6F
FDTW140KXE6F
102
Model No.
FDTW28KXE6F
FDTW45KXE6F
FDTW56KXE6F
FDTW71KXE6F
RCN-TW-E
FDTW90~140
Flexible hose
750mm
Installation workability
Transparent
access hole to
drain pan
Drainage spout
Cleaning
Cleaning
required
A circumscribes
circle is visible
650
not required
Specifications
invisible
102
A cross is visible
invisible
102
Item
Model
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound power level dB(A)
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
FDTW28KXE6F
FDTW45KXE6F
FDTW56KXE6F
FDTW71KXE6F
FDTW90KXE6F
FDTW112KXE6F
FDTW140KXE6F
2.8
3.2
4.5
5.0
5.6
6.3
7.1
8.0
1 Phase 220-240V, 50Hz
0.14-0.14
0.14-0.14
9.0
10.0
11.2
12.5
14.0
16.0
Net weight
kg
Air flow
m3/min
Outside air intake
Panel
Air filter, Qty
Remote control(option)
Unit:20 Panel:8.5
0.09-0.09
0.09-0.09
0.10-0.10
0.10-0.10
58
Hi:38 Me:34 Lo:31
65
Hi:45 Me:41 Lo:37
Unit:325x820x620 Panel:20x1120x680
Liquid line:6.35(1/4")
Installation data
Refrigerant piping size mm(in) Gas line:9.52(3/8")
Unit:21 Panel:8.5
Hi:12 Me:10 Lo:9
0.19-0.19
0.19-0.19
Unit:325x1535x620 Panel:20x1835x680
Unit:23 Panel:8.5
Unit:35 Panel:13
Hi:27 Me:23 Lo:20
Possible
TW-PSA-26W-E
Pocket Plastic net x2 (Washable)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-TW-E
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
TW-PSA-46W-E
Pocket Plastic net x3 (Washable)
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDTW28/45/56/71 42dB(A), FDTW90/112/140 48dB(A). Air flow: FDTW28/45/56/71 14.5m3/min, FDTW90/112/140 31m3/min.
38
39
R410A
Model No.
FDTS45KXE6F
FDTS71KXE6F
Dimensions
All measurements in mm.
Wired
RCN-TS-E
Compact design
Flexible hose
600mm
220mm
Specifications
Item
Model
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound power level dB(A)
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
FDTS45KXE6F
FDTS71KXE6F
4.5
5.0
7.1
8.0
1 Phase 220-240V, 50Hz
0.04
0.04
60
Hi:40 Me:38 Lo:35
0.09
0.09
61
Hi:46 Me:41 Lo:36
Unit:220x1150x565 Panel:35x1250x650
Net weight
kg
Air flow
m3/min
Outside air intake
Panel
Air filter, Qty
Remote control(option)
Unit:27 Panel:5
Hi:12 Me:11 Lo:9.5
Installation data
Refrigerant piping size mm(in)
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
Unit:28 Panel:5
Hi:15 Me:12 Lo:9.5
Possible
TS-PSA-3AW-E
Pocket Plastic net x2 (Washable)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-TS-E
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDTS45 42dB(A), FDTS71 49dB(A). Air flow: FDTS45 13m3/min, FDTS71 17m3/min.
40
41
R410A
Dimensions
All measurements in mm.
Model No.
FDTQ22KXE6F
FDTQ28KXE6F
FDTQ36KXE6F
Wired
RCN-KIT3-E
Compact design
35
63
285
Fresh air
opening
for ducting
(Knock out)
250
295~325
210
600 or less
Max.Drain up
Holes for
tapping screws
Specifications
Model
Item
FDTQ22KXE6F
FDTQ28KXE6F
FDTQ36KXE6F
Direct blow panel
Duct panel
Direct blow panel
Duct panel
Direct blow panel
Duct panel
Panel Name
Panel mode (Option)
TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER TQ-PSA-15W-E TQ-PSB-15W-E QR-PNA-14W-ER QR-PNB-14W-ER
Nominal cooling capacity kW
2.2
2.8
3.6
Nominal heating capacity kW
2.5
3.2
4.0
Power source
1 Phase 220-240V, 50Hz
Cooling
0.05-0.07
0.05-0.07
0.05-0.07
Power
consumption Heating kW
0.05-0.07
0.05-0.07
0.05-0.07
Sound power level dB(A)
60
Sound pressure level dB(A)
Hi:41 Me:38 Lo:33
Hi:41 Me:38 Lo:33
Hi:41 Me:38 Lo:33
Hi:41 Me:38 Lo:33
Hi:41 Me:38 Lo:33
Hi:41 Me:38 Lo:33
250x570x570
250x570x570
250x570x570
Exterior dimensions Unit
mm
HxWxD
35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650 35x625x650 35x780x650
Panel
Net weight
kg Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3 Unit:23 Panel:2.5 Unit:23 Panel:3
Air flow
Hi:7 Me:6 Lo:5
Hi:7 Me:6 Lo:5
Hi:7 Me:6 Lo:5
Hi:7 Me:6 Lo:5
Hi:7 Me:6 Lo:5
Hi:7 Me:6 Lo:5
m3/min
Outside air intake
Possible
Air filter, Qty
Pocket Plastic net x1 (Washable)
Remote control(option)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E
Installation data
Refrigerant piping size mm(in)
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Dimension Table
model
Unit:mm
TQ-PSA-15W-E
625
514
650
580
TQ-PSB-15W-E
780
514
650
580
Dimension Table
model
Unit:mm
QR-PNA-14W-ER
625
650
580
QR-PNB-14W-ER
780
650
580
Powerful-Hi can be selected. Sound pressure level: FDTQ22/38/36 45dB(A). Air flow: FDTQ22/38/36 8m3/min.
42
43
R410A
RC-E5
RC-EX1A
RCH-E3
Wireless
RCN-KIT3-E
Thin design
FDU45KXE6F, 56KXE6F
Model No.
FDU45KXE6F
FDU56KXE6F
FDU71KXE6F
FDU90KXE6F
FDU112KXE6F
FDU140KXE6F
FDU160KXE6F
Duct
Dimensions
Duct
280mm
Previous
Current
297
350
280
280
FDU71KXE6F
FDU112/140KXE6F
17mm less!!
70mm less!!
Reduction of weight
FDU71KXE6F, 90KXE6F
Longer Duct
Ceiling
Keep the same
air flow volume
case1
case2
Setting No.
No.8
E.S.P.
80Pa
10~130Pa
10~200Pa
Net weight
kg
Air flow (Standard) m3/min
Maximum external static pressure Pa
Outside air intake
Air filter
Remote control(option)
Installation data
Refrigerant piping size mm(in)
6kg less!!
29kg less!!
9kg less!!
12dB(A) less!!
Current
0
10
15
20
Previous
FDU90KXE6F
FDU112KXE6F
FDU140KXE6F
Specifications
Model
Item
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound power level dB(A)
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
34
34
54
Previous
Current
40
63
63
Previous
FDU71KXE6F
FDU90KXE6F
FDU112/140KXE6F
25
30
Current
37
38
39
25
30
29
35
40 dB(A)
Lo mode
12dB(A) less!!
8dB(A) less!!
10dB(A) less!!
FDU45KXE6F
FDU56KXE6F
FDU71KXE6F
4.5
5.0
5.6
6.3
7.1
8.0
0.10-0.10/0.10
0.10-0.10/0.10
60
Hi:32 Me:29 Lo:26
FDU90KXE6F
FDU112KXE6F
9.0
11.2
10.0
12.5
1 Phase 220-240V, 50Hz
0.24-0.25/0.24
0.31-0.32/0.31
0.24-0.25/0.24
0.31-0.32/0.32
65
Hi:33 Me:29 Lo:25
Hi:38 Me:36 Lo:30
280x750x635
280x950x635
29
Hi:10 Me:9 Lo:8
34
Hi:19 Me:15 Lo:10
FDU140KXE6F
FDU160KXE6F
14.0
16.0
16.0
18.0
0.35-0.36/0.35
0.35-0.36/0.35
0.42-0.43/0.42
0.42-0.43/0.42
280x1370x740
Hi:28 Me:25 Lo:19
54
Hi:32 Me:26 Lo:20
200
Possible
Procure locally
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. External static
pressure of indoor unit is 60Pa.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDU45/56 37dB(A), FDU71/90 38dB(A), FDU112 44dB(A), FDU140 45dB(A),FDU160 47dB(A). Air flow: FDU45/56 13m 3/min, FDU71/90 24m3/min, FDU112 36m3/min, FDU140
39m3/min, FDU160 48m3/min.
44
45
R410A
RC-EX1A
RC-E5
Dimensions
All measurements in mm.
RCH-E3
Wireless
RCN-KIT3-E
VIEW
VIEW
Fan motor
Specifications
Model
Item
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound power level dB(A)
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
Net weight
kg
Air flow (Standard) m3/min
Maximum external static pressure Pa
Outside air intake
Air filter
Remote control(option)
Installation data
Refrigerant piping size mm(in)
FDU224KXE6F
FDU280KXE6F
22.4
25.0
28.0
31.5
1 Phase 220-240V, 50Hz
0.94-1.03
0.86-0.90
0.96-1.05
0.88-0.96
Hi:51
Hi:52
360x1570x830
92
Hi:51
Hi:68
200
Possible(on Return duct)
Procure locally
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E
Liquid line:9.52(3/8")
Gas line:19.05(3/4")
Liquid line:9.52(3/8")
Gas line:22.22(7/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. External static
pressure of indoor unit is 100Pa.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
3. Values of sound pressure level become increased 5dB(A), when external static pressure is 200Pa (factory setting).
4. Values of air flow volume are those at external static pressure 200Pa (factory setting).
46
47
R410A
Dimensions
All measurements in mm.
FDUM71KXE6F
FDUM90KXE6F
FDUM112KXE6F
FDUM140KXE6F
FDUM160KXE6F
Wireless
RC-E5
RCH-E3
Thin design
Fan unit (impeller and motor) can be pulled out from the right side
or the bottom side of the unit. Maintenance can be available from
the right side or the bottom side.
RCN-KIT3-E
FDUM71KXE6F, 90KXE6F
70mm less
H 350
H 280
Pipe
Fan unit
Unit
FDUM112/140KXE6F
Maintenance
hole
19mm less
Service
space
H 299
H 280
(mm)
FDUM22~90KXE6F
Specifications
Model FDUM22KXE6F FDUM28KXE6F FDUM36KXE6F FDUM45KXE6F FDUM56KXE6F FDUM71KXE6F FDUM90KXE6F FDUM112KXE6F FDUM140KXE6F FDUM160KXE6F
Item
Nominal cooling capacity kW
2.2
2.8
3.6
4.5
5.6
7.1
9.0
11.2
14.0
16.0
Nominal heating capacity kW
2.5
3.2
4.0
5.0
6.3
8.0
10.0
12.5
16.0
18.0
Power source
1 Phase 220-240V, 50Hz
Cooling
0.10-0.10
0.20-0.20
0.29-0.29
0.33-0.33
0.45-0.45
Power
consumption Heating kW
0.10-0.10
0.20-0.20
0.29-0.29
0.33-0.33
0.45-0.45
Sound power level dB(A)
60
65
Hi:32 Me:29 Lo:26
Hi:38 Me:36 Lo:30 Hi:40 Me:34 Lo:29 Hi:40 Me:35 Lo:30
Sound pressure level dB(A)
Hi:33 Me:29 Lo:25
Exterior dimensions
280 x 750 x 635
280 x 950 x 635
280 x 1370 x 740
mm
HxWxD
Net weight
Air flow
Maximum external
static pressure
29
Hi:10 Me:9 Lo:8
kg
m3/min
34
Hi:19 Me:15 Lo:10
100
Pa
54
Hi:28 Me:25 Lo:19 Hi:32 Me:26 Lo:20 Hi:35 Me:28 Lo:22
Possible
Filter kit:UM-FL1EF/UM-FL2EF/UM-FL3EF(option)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. External static
pressure of indoor unit is 35Pa(22/28/36/45/56/71/90), 60Pa(112/140/160).
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDUM22/28/36/45/56 37dB(A), FDUM71/90 38dB(A), FDUM112 44dB(A), FDUM140 45dB(A), FDUM160 47dB(A). Air flow: FDUM22/28/36/45/56 13m3/min, FDUM71/90
24m3/min, FDUM112 36m3/min, FDUM140 39m3/min, FDUM160 48m3/min.
48
Company
e-mail
tel
AIRZONE
jmoral@altracorporacion.es
+34-902-400-445
49
R410A
Model No.
FDUT15KXE6F-E
FDUT22KXE6F-E
FDUT28KXE6F-E
FDUT36KXE6F-E
FDUT45KXE6F-E
FDUT56KXE6F-E
FDUT71KXE6F-E
Dimensions
All measurements in mm.
RC-EX1A
RC-E5
RCH-E3
Wireless
RCN-KIT3-E
Expansion of lineup
Previous
Current
(1) Can not be connected to some KX outdoor units. Please consult your dealer for further details.
(2) Regarding pipe length (150m or more is required) and temperature condition (the lowest is 10C) in the cooling operation etc. , please refer to our technical manual.
FDUT45KXE6F-E, 56KXE6F-E
Item
Contents
for FDUT15/22/28/36KXE6F-E
for FDUT45/56KXE6F-E
for FDUT71KXE6F-E
UT-SAT1EF
UT-SAT2EF
UT-SAT3EF
UT-FL1EF
2+3
UT-FL2EF
UT-FL3EF
FDUT22KXE6F-E
FDUT28KXE6F-E
FDUT36KXE6F-E
FDUT45KXE6F-E
FDUT56KXE6F-E
FDUT71KXE6F-E
2.2
2.5
2.8
3.2
3.6
4.0
1 Phase 220-240V, 50Hz
4.5
5.0
5.6
6.0
7.1
8.0
0.07-0.07
0.07-0.07
52
Hi:28 Me:26 Lo:22
Hi:32 Me:29 Lo:26
57
Hi:33 Me:30 Lo:26
Hi:37 Me:34 Lo:28
58
Hi:34 Me:32 Lo:28
Hi:36 Me:33 Lo:27
200x750x500
21
0.08-0.08
0.08-0.08
22
Hi:8.5 Me:7 Lo:5.5
FDUT71KXE6F-E
0.08-0.08
0.07-0.07
59
200x950x500
220x1150x565
25
31
Hi:16 Me:13 Lo:9.5
Not possible
Filter set:UT-FL1EF/UT-FL2EF/UT-FL3EF(option)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. External static
pressure of indoor unit is 10Pa.
2. The data of nominal cooling and heating capacity and sound pressure level are measured with 10Pa of external static pressure.
3. The sound level indicates the value of rear-intake type with duct in anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
4. Sound pressure levels are values when 2m supply duct and 1m return duct are connected.
1 : Mike position is 1.5m below unit, 2 : Mike position is 1m in front and 1m below the air supply duct.
50
51
R410A
32.5
83.3
53
32
27.6
Holes for
tapping screws
257
mm
488
(D)
530m
68
549.2
12-4
RCH-E3
(option)
Considering specialized
usage in hotel rooms,
control buttons are limited
only to minimum required
functions such as ON/OFF,
mode, temperature setting
and fan speed. It is really
simple and easy to use.
32
27.5
160
200
Air inlet
150
150
494.2
574
150
30
28.3
Control box
38.2
37.6
188.5
148.5
Control box and drain piping can be installed on both side of the unit and air intake
to the unit is available from bottom or back side. Our highest technology can satisfy
diverse installation requirements.
30
Holes for
tapping screws
Installation Flexibility
30.8
66
570mm
62.1
Control box
Note(4)
Air
inlet
255.8
C2
600
32
27.5
890
100
Unit:mm
21
Quiet operation
FDUH36KXE6F
12.7 (1/2") (Flare)
273
66.4
A
Compact and thin size, light weight
156.8
32
27.6
21
C1
UH-FL1E
575.2
66
95.3
30.8
145.6
Air
outlet
150
(Duct dimension)
(600mm)
RCN-KIT3-E
150
494
Content
FDUH22KXE6F,28KXE6F
9.52 (3/8") (Flare)
6.35 (1/4") (Flare)
610
150
40
12-4
Model
Gas piping
Liquid piping
Drain piping
Hole for wiring
Suspension bolts
Inspection hole
530
Wireless
UH-DU-E
A
B
C1,C2
D
E
F
100
145
RC-E5 RCH-E3
Symbol
(Duct dimension)
30.8
RC-EX1A
Model No.
FDUH22KXE6F
FDUH28KXE6F
FDUH36KXE6F
Dimensions
32.5
Notes
( 1 ) The model name label is attached on the fan case
inside the air return grille.
( 2 ) Prepare the connecting socket (VP20) on site.
(As for drain piping, it is possible to choose C1 or C2)
( 3 ) When control box is located on the reverse side, Installation
space should be modified to new location.
( 4 ) Contorl box and Drain hose piece are able to be relocated
on the reverse side.
G
Bottom plate
(Able to be located on the back side)
Drain piping
Specifications
Installation data
mm(in)
Refrigerant piping size
View G
FDUH36KXE6F
3.6
4.0
Holes for
tapping screws
50.5
18.2
150
150
150
28.5
2.8
3.2
1 Phase 220-240V, 50Hz
0.05-0.07
0.05-0.07
60
HI: 33 Me: 30 Lo: 27
257x570x530
22
HI: 7 Me: 6.5 Lo: 6
30
Not possible
Filter kit:UH-FL1E(option)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
30
FDUH28KXE6F
120
537.6
Air inlet
160
2.2
2.5
198.2
FDUH22KXE6F
30
Item
Model
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound power level dB(A)
Sound pressure level dB(A)
Exterior dimensions HxWxD mm
Net weight
kg
Air flow
m3/min
External static pressure Pa
Outside air intake
Air filter
Remote control(option)
70
15
View G
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDUH22/28/36 39dB(A). Air flow: FDUH22/28/36 8.5m3/min.
52
53
R410A
Wall Mounted
FDK
Dimensions
Remote control (option)
Wired
Model No.
FDK22KXE6F
FDK28KXE6F
FDK36KXE6F
FDK45KXE6F
FDK56KXE6F
FDK71KXE6F
RC-E5
RCH-E3
Wireless
RCN-K-E : FDK22~56
RCN-K71-E : FDK71
FDK71
Installation Workability
Innovative Design
259
Fast
Slow
Improved Maintainability
FDK71KXE6F
Upper
position
Movable
range
Lower
position
Specifications
Model
Item
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound power level dB(A)
Sound pressure Cooling dB(A)
level
Heating
FDK22KXE6F
FDK28KXE6F
2.2
2.5
2.8
3.2
Installation data
Refrigerant piping size mm(in)
FDK45KXE6F
3.6
4.5
4.0
5.0
1 Phase 220-240V, 50Hz
0.05
0.04
57
Hi:35 Me:33 Lo:31
Hi:35 Me:33 Lo:31
FDK56KXE6F
FDK71KXE6F
5.6
6.3
7.1
8.0
0.05
0.05
60
Hi:41 Me:35 Lo:31
Hi:39 Me:35 Lo:31
Exterior dimensions
mm
HxWxD
Net weight
kg
Air flow
m3/min
Outside air intake
Air filter, Qty
Remote control(option)
FDK36KXE6F
0.09
0.09
Hi:46 Me:42 Lo:37
Hi:46 Me:42 Lo:37
12
12.5
13
Hi:8 Me:7 Lo:6
Hi:10 Me:9 Lo:7
Hi:11 Me:9 Lo:7
Hi:14 Me:12 Lo:10
Not possible
Polypropylene net x2 (Washable)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-K-E (for FDK22~56), RCN-K71-E (for FDK71)
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
15.5
Hi:21 Me:18 Lo:15
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDK22/28 38dB(A), FDK36 48dB(A)(Cooling)&42dB(A)(Heating), FDK45 48dB(A)(Cooling)&43dB(A)(Heating), FDK56 48dB(A)(Cooling)&47dB(A)(Heating), FDK71 48dB(A).
Air flow: FDK22/28 11m3/min, FDK36/45 15m3/min, FDK56 16m3/min, FDK71 24m3/min.
54
55
R410A
C1,C2
135
24
990
108
40
690
1070
235
Air supply
76
A C1
75
110
150 or more
175
12
19
5 or more
Obstacle
135
Content
Gas piping
12.7 (1/2") (Flare)
6.35 (1/4") (Flare)
Liquid piping
Drain piping
VP20 (I.D.20)
Hole for suspension bolt
(M10 or M8)
Back cutout
PE cover
Top cutout
Plate cover
Hole for drain piping (for left back) (Knock out)
Hole for
drain piping
(for left)
300 or more
308
C2
Make a space of 4000 or more between the units when installing more than one.
24
410
145
215
1240
40
690
1320
A C1
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
37
Hi:16 Me:14 Lo:12
Not possible
Pocket Plastic net x2 (Washable)
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-E-E
135
24
410
68
145
52
B
A
1540
40
108
690
1620
271
49
Hi:26 Me:23 Lo:21
195
235
Air supply
53
109
40
31
C ,C
20
1 2
Drain hose piece (Accessory, 0.3m)
(Installed on site)
15
100
60
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
Powerful-Hi can be selected. Sound pressure level: FDE36/45/56 46dB(A), FDE71 50dB(A), FDE112 46dB(A), FDE140 50dB(A). Air flow: FDE36/45/56 11m3/min, FDE71 18m3/min, FDE112 28m3/min, FDE140 32m3/min.
C2
76
A C1
75
110
135
Symbol
A
B
C1,2
D
E
F
G
Content
Gas piping
Liquid piping
Drain piping
Hole for suspension bolt
Back cutout
Top cutout
Hole for drain piping (for left back)
20
100 or more
27
53
10
0.16-0.18
0.15-0.17
40
0.14-0.16
0.13-0.15
24
Hole for
drain piping
(for left)
C1,C2
FDE112KXE6F, 140KXE6F
300 or more
28
Hi:10 Me:9 Lo:7
14.0
16.0
11.2
12.5
Obstacle
255
FDE140KXE6F
19
5 or more
250
0.05-0.06
0.05-0.06
60
Hi:39 Me:38 Lo:36
5.6
7.1
6.3
8.0
1 Phase 220-240V, 50Hz
0.10-0.11
0.09-0.10
62
Hi:41 Me:39 Lo:37
FDE112KXE6F
150 or more
Make a space of 4500 or more between the units when installing more than one.
173
4.5
5.0
FDE71KXE6F
135
308
3.6
4.0
FDE56KXE6F
110
175
12
27
76
75
Content
Gas piping
Liquid piping
Drain piping
Hole for suspension bolt
Back cutout
Top cutout
Hole for drain piping(for left back)
300 or more
308
C2
FDE45KXE6F
20
100 or more
Symbol
A
B
C 1,2
D
E
F
G
Rear
Right
FDE36KXE6F
60
15
100
Up
Specifications
1 2
Drain hose piece (Accessory, 0.3m)
(Installed on site)
235
271
Installation Workability
20
C ,C
195
Air supply
27
40
53
109
Slim and sleek design starting at just 28kgs in weight means quick,
easy & neat installation.
108
210
173
Lower
position
53
B
A
52
68
31
24
135
27
210mm
40
FDE71KXE6F
10
C1,C2
Upper
position
is not applicable to
*RCH-E3
the Flap control system.
56
100 or more
Symbol
A
B
C 1,2
D
E
F
G
271
Movable
range
Installation data
Refrigerant piping size mm(in)
60
100
20
Net weight
kg
Air flow
m3/min
Outside air intake
Air filter, Qty
Remote control(option)
20
C1,C2
195
15
27
40
53
109
173
Wireless
Small
Light-weight
Quiet
Sleek, intelligent design
Model
Item
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound power level dB(A)
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
B
A
52
RCN-E-E
Selection of flap
position is possible.
A flap can be set at
different angles.
145
68
5
RCH-E3
D
410
210
RC-EX1A RC-E5
27
24
215
Model No.
FDE36KXE6F
FDE45KXE6F
FDE56KXE6F
FDE71KXE6F
FDE112KXE6F
FDE140KXE6F
31
10
Wired
Dimensions
53
40
Ceiling Suspended
FDE
0
12
175
19
F
150 or more
5 or more
Obstacle
Make a space of 5000 or more between the units when installing more than one.
Hole for
drain piping
(for left)
57
R410A
Dimensions
All measurements in mm.
Model No.
FDFW28KXE6F
FDFW45KXE6F
FDFW56KXE6F
Remote control (option)
Wireless
Wired
RC-EX1A
RC-E5 RCH-E3
RCN-FW-E
Quiet Operation
Sophisticated Design
With classy semi flat front panel in chic white, the new
series fit in various kinds of rooms and create relaxing
atmosphere. Choice of wall hanging, floor standing or
behind gallery installation is available.
Flap control system
Selection of flap
position is possible.
A flap can be set at
different angles.
Upper
position
Movable
range
is not applicable to
*RCH-E3
the Flap control system.
Lower
position
Specifications
Model
Item
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound power level dB(A)
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
FDFW28KXE6F
FDFW45KXE6F
FDFW56KXE6F
2.8
3.2
4.5
5.0
1 Phase 220-240V, 50Hz
0.02-0.02
0.02-0.02
57
Hi:38 Me:36 Lo:33
5.6
6.3
0.02-0.02
0.02-0.02
55
Hi:36 Me:34 Lo:30
0.03-0.03
0.03-0.03
60
Hi:44 Me:37 Lo:33
600x860x238
Net weight
kg
Air flow (Standard) m3/min
Air filter, Qty
Remote control(option)
19
Installation data
Refrigerant piping size mm(in)
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
20
Hi:9 Me:8 Lo:7
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
58
59
R410A
Wired
RC-EX1A
RC-E5 RCH-E3
RCN-KIT3-E
Dimensions
All measurements in mm.
FDFL
Model No.
FDFL71KXE6F
FDFU28KXE6F
FDFU45KXE6F
FDFU56KXE6F
FDFU71KXE6F
FDFL
FDFU
Specifications
Item
Model
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound power level dB(A)
Sound pressure level dB(A)
Exterior dimensions
mm
HxWxD
FDFL71KXE6F
FDFU28KXE6F
7.1
8.0
2.8
3.2
0.09-0.10
0.09-0.10
62
Hi:43 Me:41 Lo:40
58
Hi:41 Me:38 Lo:36
FDFU45KXE6F
FDFU56KXE6F
FDFU71KXE6F
5.6
6.3
7.1
8.0
4.5
5.0
1 Phase 220-240V, 50Hz
0.09-0.10
0.09-0.10
60
Hi:43 Me:41 Lo:40
630x1481x225
630x1077x225
630x1362x225
Net weight
kg
Air flow (Standard) m3/min
Air filter, Qty
Remote control(option)
40
Hi:18 Me:15 Lo:12
25
Hi:12 Me:11 Lo:10
32
Hi:18 Me:15 Lo:12
Installation data
Refrigerant piping size mm(in)
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
Dimension Table
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
60
model
Unit:mm
786
810
722
750
806
FDFU71KXE6F
1071
1095
1007
1035
1091
61
R410A
Model No.
FDU500FKXE6F
FDU850FKXE6F
FDU1300FKXE6F
FDU1800FKXE6F
RC-EX1A
RC-E5 RCH-E3
FDU-F series are connectable to 8~60HP outdoor units, not connectable to 4~6HP.
8 ~ 60 HP : Yes , 4 ~ 6 HP : No
Wireless
RCN-KIT3-E
Air conditioning and intake of outdoor air are in the same system
Combination
The total capacity of FDU-F is 50~100% of outdoor capacity
and max quantity of FDU-F is 2 units.
The total capacity of FDU-F and dedicated air-conditioners is 50~100% of outdoor
capacity and max quantity of FDU-F should be below 30% of outdoor unit capacity.
[A]
KXZ outdoor unit
indoor unit
10HP
[B]
FDU850FKXE6F FDU850FKXE6F
(5HP)
(5HP)
18HP
FDU850FKXE6F
(5HP)
6HP
6HP
indoor unit
Outdoor Air
Processing unit
office
air
conditioning
outside
air supply
corridor
refresh room,
rest room
Compact design
SAF is the energy recovery ventilation unit which can recover heat energy from exhaust air to supply air and "has no air processing
function, but FDU-F is air processing unit which can treat the supply air closer to room temperature by cooling or heating in connection
with KXZ refrigerant system and exhaust air is discharged to outside of the room.
exhaust air
Outside
outdoor air
supply air
Air Supply
Exhaust Air
outdoor air
supply air
Direct Expansion
Heat Exchanger
(1) This unit is the specific unit for processing the outdoor air temperature closer to the room temperature. For conditioning the room temperature a
dedicated air-conditioner is required additionally.
(2) This unit monitors the outdoor air temperature and controls thermostat ON/OFF at the setting temperature by the remote controller, which
indicates the outdoor air temperature for controlling thermostat ON/OFF. When thermostat is turned OFF, the operation is changed to the fan mode
so that unprocessed outdoor air will be blown into the room directly. Therefore place the air outlet port or orient the air outlet direction not to blow
air directly to persons in the room, especially in the small room such as a restroom and/or sanitary hot water supplying room.
(3) It is strictly prohibited to monitor the room temperature by switching to the thermistor at remote controller side and/or the optional remote
thermistor. Otherwise dew formation at air outlet port and/or dew dripping may occur during cooling operation due to the lower outdoor air
temperature. Therefore keep the remote controller of this unit in place closer to the administrator so as not to be touched it freely by the end user.
(4) Dehumidifying operation with this unit is prohibited.
(5) When handing over this unit to the end user, make sure to explain sufficiently about the foregoing cautions, the installation place and usage of
remote control for this unit and the location of the air outlet.
62
SAF
Outside
Air Supply
Exhaust Air
63
R410A
FDU1300FKXE6F
FDU1800FKXE6F
14.0
7.0
22.4
10.9
28.0
14.8
0.11
0.11
38
0.16
0.16
41
0.27
0.27
43
0.31
0.31
46
360x820x830
360x1200x830
48
8.5
510
62
14
840
kg
m3/min
CMH
External static pressure Pa
Air filter, Q'ty
Remote control(option)
Air flow (Standard)
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
Installation data
mm
Refrigerating piping size (in)
82
22
1320
84
30
1800
200
Procure locally
wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E
Liquid line:9.52(3/8")
Gas line:19.05(3/4")
Control box
16-M5 screw
Liquid line:9.52(3/8")
Gas line:22.22(7/8")
1. The data are measured at 33CDB 28CWB (68%RH) during cooling and 0CDB-2.9CWB (50%RH) during heating (no frost). External static pressure of indoor unit with optional fan controlling kit "U-FCRB" is 100Pa.
2. Temperature range of outdoor air must be 20~40CDB (32CWB) during cooling and -10~24CDB during heating.
3. Operation sound is measured in an anechoic room based on JIS standard. In case of actual room installation, it usually becomes higher than the displayed value due to the surrounding noise and echo.
4. The total connection capacity of the other standard air conditioning units and the outdoor air processing units must be from 50% to 100% (the total includes the outdoor air processing unit). The connection capacity
of the outdoor air processing unit must not exceed 30% of the capacity of the outdoor unit.
5. Single outdoor air processing unit can be used alone. The connection capacity of the outdoor air processing unit must be from 50% to 100% of the total capacity of the outdoor unit.
6. Single outdoor air processing unit can be used alone. Maximum number of outdoor air processing units that can be connected to the outdoor unit is 2units.
7. Values of sound pressure level become increased 5dB(A), when external static pressure is 200Pa (factory setting).
8. Values of air flow volume are those at external static pressure 200Pa (factory setting).
or more
or more
Plan view
Installation space
or more Installation space
Below
Installation space
Symbol
Ceiling
or more
Piping space
Dimensions
Content
Gas piping
Liquid piping
Drain piping connection
Power supply wiring connection
Suspension bolt
Inspection Opening
Inspection Opening
Slab
Service space
12-M5 screw
Above
(Below suspension
bolt pitch)
Net weight
360x1570x830
FDU850FKXE6F
9.0
4.2
or more
FDU500FKXE6F
Model
Item
Nominal cooling capacity kW
Nominal heating capacity kW
Power source
Cooling
Power
consumption Heating kW
Sound pressure level dB(A)
Exterior dimension
mm
HxWxD
FDU850FKXE6F
or more
Specifications
FDU1300FKXE6F, FDU1800FKXE6F
12-M5 screw
Control box
20-M5 screw
20-M5 screw
Plan view
or more
or more
Installation space
Installation space
Front view
or more
Installation space
or more
Slab
64
or more
Piping space
(Service from below)
or more
Ceiling
Service space
Above
Below
Installation space
Symbol
Content
Gas piping
Liquid piping
Drain piping connection
Power supply wiring connection
Suspension bolt
Inspection Opening
Inspection Opening
or more
Plan view
or more
or more
Installation space
Below
or more
(Below suspension
bolt pitch)
Above
Symbol
Slab
Ceiling
Service space
Service space
or more
Piping space
or more
12-M5 screw
Control box
(Below suspension
bolt pitch)
FDU500FKXE6F
Content
Gas piping
Liquid piping
Drain piping connection
Power supply wiring connection
Suspension bolt
Inspection Opening
Inspection Opening
65
R410A
Structure (SAF800E6)
Exhaust Air
SAF150E6
SAF250E6
SAF350E6
SAF500E6
SAF650E6
SAF800E6
SAF1000E6
RA
(Room Air)
EA
(Exhaust Air)
105
105
95
120
140
SAF350E6
SAF500E6
SAF800E6
OA
(Outside Air)
SA
(Supply Air)
1
105
SAF1000E6
SAF250E6
SAF150E6
SAF250E6
SAF350E6
mm
270x970x467
270x882x599
317x1050x804
W
A
92-107
0.42-0.45
63
70
108-123
0.49-0.51
63
70
178-185
0.81-0.77
66
69
63
70
63
70
66
69
Capacity
Enthalpy
exchange
efficiency
Cooling
Heating
UHi
Temperature exchange efficiency
Enthalpy
Cooling
exchange
Hi efficiency
Heating
Temperature exchange efficiency
Enthalpy
Cooling
exchange
Lo efficiency
Heating
Temperature exchange efficiency
66
UHi
Hi
Lo
UHi
Hi
Lo
SAF150E6
SAF500E6
m3/h
Pa
kg
66
73
77
65
72
77
71
73
78
20 x 2
20 x 2
40 x 2
150
150
120
80
70
25
25
250
250
190
105
95
45
29
350
350
240
140
60
45
49
12
317x1090x904
Galvanized steel sheet
204-225
0.93-0.94
62
67
75
62
67
75
64
69
76
Model No.
Nominal
diameter
SAF150E6
SAF250E6
SAF350E6
SAF500E6
100
27 C
388x1204x884
388x1322x884
388x1322x1134
269-295
1.22-1.23
62
68
360-378
1.64-1.58
416-432
1.89-1.80
NO.
Name
Frame
65
71
65
71
Adaptor
Terminal board
62
68
65
71
65
71
Inspection Cover
SAF350E6
SAF500E6
70
76
79
70 x 2
Sirocco fan x 2
100 x 2
180 x 2
180 x 2
500
500
440
120
60
35
57
Included
650
650
460
65
40
40
68
800
800
630
140
110
55
71
1000
1000
700
105
80
75
83
10
Qt'y
Fan
Motor
1
1
2
2
3
3
4
Filter
EA
(Exhaust Air)
RA
(Room Air)
OA
(Outside Air)
SA
(Supply Air)
Damper
10
Damper Motor
11
Suspension fitting
12
200
4-13 x 30
oblong hole
Model No.
SAF650E6
SAF800E6
SAF1000E6
12
Dimension table
Model
525
SAF1000E6
68
74
76
150
98 110
82 303 82
810
135 159 270
655
142 315 142
164
19
144
978 860
112 580 112
162
804 1050
70
159 182 317
132 640 132
1018 960
194 210
904 1090
467 970 49
599 882 95
SAF800E6
66
73
79
Applied duct
Unit:mm
SAF650E6
Power input
Running current
35 C
11
Dimension table
Model
Model
27 C
Room Air
4-13 x 30
oblong hole
Applied duct
Specifications
Item
Power source
Exterior dimensions
Height x Width x Depth
Exterior appearance
29 C
4
SAF250E6
Supply Air
Outside Air
RA
(Room Air)
Previous Current
90
indoor
EA
(Exhaust Air)
11
140
Room Air
10 C
outdoor
33 C
10
Pa
90
10 C
140
Exhaust Air
80
Supply Air
Dimensions
Capturing this waste energy, means the heating/ cooling requirements
of the building are reduced, so smaller size plant can be selected,
savings can be made in long term energy consumption, and carbon
emissions are reduced.
100
indoor
27 C
SA
(Supply Air)
OA
(Outside Air)
120
outdoor
ENERGY RECOVERY
Outside Air
140
FREE COOLING
Damper
200
250
Unit:mm
1204 70 1132
SAF650E6
Nominal
diameter
194 210
940
884
19
194 218 388
428
SAF800E6
1322 85 1250
242 258
228
612
1190
SAF1000E6 1134
678
Installation reference
Air supply duct
Ceiling suspension bolt
Outer air intake duct
Pipe hood
SA
(Supply Air)
RA
(Room Air)
OA
(Outside Air)
Pipe hood
EA
(Exhaust Air)
Heat insulation
material
Note:An inspection port is needed for cleaning the heat exchanger and filter 1 or 2 times a year.
67
R410A
Remote control
(option)
Drain up kit
(option, built-in type)
(600mm)
Wired
DXA-DU-E
RC-E5
Dimensions
All measurements in mm.
SAF-DX250E6,350E6
SAF-DX500E6
SAF-DX800E6
SAF-DX1000E6
RCH-E3
Wireless
Model No.
SAF-DX250E6
SAF-DX350E6
SAF-DX500E6
SAF-DX800E6
SAF-DX1000E6
RCN-KIT3-E
SAF-DX is a heating or cooling coil incorporating MHI KXZ series controls. It can be used in combination with our SAF series of total heat exchanger.
Combination of SAF-DX together with other KXZ indoor units is possible. The capacity code index of each model is shown below and must be used when
making the system selection. Total capacity code index must be within 100% of outdoor unit capacity code index.
Remote control option is the same as with other KXZ indoor units (see above). Connection to all superlink controls is also possible.
Optional condensate lift mechanism is also available (600mm height).
Return air temp. control or supply air temp. control can be selectable.
RA
OA
(Outside Air)
(Room Air)
SAF-DX
Total heat
exchanger
EA
SA (Supply Air)
(Exhaust Air)
SAF-DX can provide heating or cooling to the fresh air supplied through a 3rd party air handling unit or total heat exchanger such as our SAF series.
Specifications
Item
Model
Nominal cooling capacity *1 kW
Nominal heating capacity *2 kW
Capacity code
Power source
Cooling
Power
consumption Heating W
Cooling
Running
A
current
Heating
SAF-DX250E6
SAF-DX350E6
SAF-DX500E6
SAF-DX800E6
SAF-DX1000E6
2.0
1.8
22
2.8
2.2
28
3.6
2.8
36
1 Phase 220-240V, 50Hz
7.2
7.2
0.05
0.05
5.6
4.5
56
6.3
5.6
71
13.6
500
16.1
800
18.4
1000
Exterior dimensions
mm
HxWxD
Net weight
kg
Air flow (Standard) CMH
Internal resistance Pa
Remote control(option)
350
66
wired: RC-E5, RCH-E3 wireless: RCN-KIT3-E
Liquid line:6.35(1/4")
Gas line:9.52(3/8")
Installation data
Refrigerant piping size mm(in)
Liquid line:6.35(1/4")
Gas line:12.7(1/2")
Liquid line:9.52(3/8")
Gas line:15.88(5/8")
Standards
ISO-T1
(2) This air-conditioner is manufactured and tested in conformity with ISO-T1 "UNITARY AIR-CONDITIONERS".
68
69
R410A
1. Basic operation
Advanced touch screen panel with full dot Liquid Crystal display
User friendly
LCD panel with light tap operation
introduced as the industry's first
Simple interface with only three buttons
Operation mode
Cooling
Fan
Dry
Heating
Auto
RC-EX1A
You can select the temperture as
desired by tapping
button.
2. Main functions
Run / Stop
High power operation
Energy-saving operation
Saving energy
Comfort
Sleep timer
Peak cut timer
Automatic temerature set back
Weekly timer
Set ON/OFF timer by hour
Set ON/OFF timer by clock
Convenience
Service
Outdoor unit
Indoor unit
Remote Control
USB
Remote Control
RC-EX1A Utility Software
71
R410A
Control Systems
<Individual control>
Remote Control line up
indoor unit remote control
RC-EX1A
wired all models
RC-E5
RCH-E3
<Control System>
(except SAF)
indoor unit remote control indoor unit
FDT
RCN-T-36W-E
FDTS
wireless
FDTC
RCN-TC-24W-ER FDK22~56
FDTW
RCN-TW-E
FDK71
remote control
RCN-E-E
RCN-FW-E
RCN-KIT3-E
SUPERLINKMHI has now combined simplicity of installation with our highly sophisticated
Superlink- control system, to offer building owners and occupiers a
comprehensive control and management system, while providing complete
commissioning and service maintenance assistance for installers and service
engineers. The Superlink- network utilises two wire, non-polar cable - for
further details of wiring.
RC-E5 allows the upper and lower limits of a set temperature range
to be specified separately.
By adjusting a set temperature range, you can ensure energy saving
air conditioning by avoiding excessive cooling or heating.
Timer operation
Changeable range
Upper limit
Lower limit
Center Control
SC-SL4-AE/BE
SC-THB-E3
Considering specialized usage in hotel rooms, control buttons are limited only to
minimum required functions such as ON/OFF, mode, temperature setting and fan
speed. It is really simple and easy to use.
AUTO restart
Thermistor (option)
RCH-E3 (wired)
Up to 16 units
SC-WGWNA-A/B
PC Control Interface
*RCH-E3 is not applicable to the Individual flap control system and the Flap control system.
*When RCH-E3 is used, the fan speed setting can only be set to 3 speed settings (Hi-Me-Lo).
RCN-T-36W-E,
RCN-TC-24W-ER
RCN-TW-E
RCN-TS-E
RCN-K-E,
RCN-K71-E
RCN-E-E
RCN-FW-E
RCN-KIT3-E
Wireless
remote
control
SC-ADNA-E
wireless remote control is not applicable to the Individual flap control system and the Flap control system.
*The
*When the wireless remote control is used, the fan speed setting can only be set to 3 speed settings (Hi-Me-Lo).
72
One-to-one
SC-ADNA-E
SC-ADNA-E
SC-ADNA-E
Wireless
73
R410A
<Central Control>
SC-SL4-AE/BE
MHI introduces the full colour touch
screen central control SC-SL4-AE/BE,
with 9 inch interactive LCD display.
Offers control, monitoring,
scheduling and service/maintenance
functions for up to 128 indoor units.
Control with PC is available by use
of internet explorer.
SC-SL1N-E
Start/stop control of up to 16 indoor units either
individually or collectively.
Simple centralised control.
1. The SC-SL1N-E is connected to the Superlink- network via 2-core, non-polar wires (AB connection).
2. It will monitor and control the start/stop function of up to 16 units, with the sixteen operation button.
3. The unit or group numbers in operation or in need of service are displayed with an LED.
4. Collective start/stop is also available through the simultaneous on/off button.
5. Up to 12 SC-SL1N-E units can be connected to a Superlink- network (consisting of up to 128 indoor
units).
6. If a power failure occurs, the SC-SL1N-E will resume the operation of the system according to a stored
operation condition, once power is restored.
SC-SL2NA-E
Central control of up to 64 indoor units including weekly timer function as standard.
1. The SC-SL2NA-E is connected to the Superlink- network via 2-core, non-polar wires (AB
connection).
2. It will monitor and control the start/stop function of up to16 units, or 16 groups of units, with the
sixteen operation buttons.
3. It also monitors and controls the following functions for individual units, groups of units or the
complete network: operation mode, set point temperature, return air temperature, louvre position,
error code. Air flow and center lock function.
4. The unit or group numbers in operation or in need of service are displayed with an LCD.
5. Collective start/stop is also available through the simultaneous on/off button.
6. If a power failure occurs, the SC-SL2NA-E will resume the operation of the system according to a
stored operation condition, once power is restored.
7. The SC-SL2NA-E can be connected to an external timer to facilitate timed on/off cycles.
8. The number of units connected to one network are detailed on the table below.
SL1N-E
Control
Monitoring
Scheduling
Administration/Service
Run/Stop
Operating state
Yearly schedule
Block definition
Internet
Explorer
Mode (cool/heat/fan/dry/Auto)
Mode
Today's schedule
Group definition
Set temperature
Set temperature
Unit definition
Operation permitted/prohibited
Room temperature
Fan speeds
Operation permitted/
prohibited
Alarm history
Air direction
Fan speed
Air direction
Filter sign
Emergency stop
Maintenance
(1, 2 or back-up)
Item
SW1
ten's place
SW2
one's place
SW3
Power supply
Power consumption
Net weight
Number of
connectable units (indoor units)
hundred's
place
Terminal block
SC-SL4-BE
Method of data export
Calculation software
Air-conditioner power proportional distribution
pulse input (Maximum)
Connecting indoor units number (Maximum)
USB / LAN
Standard
8
128
Outputs
51X 52 52R
1 2 3 4 5 6 7 8 A B
AC220-240V
Model
External dimensions
(Height x Width x Depth)
Applicable products
Ventilation fan, Air purifier
By using SC-GIFN-E together with central control such as SC-SL1N-E,
SC-SL2NA-E and SC-SL4-AE/BE, you can start-stop, operate & monitor
the operation of applicable products.
HUB
Demand control
Printed board
Ethernet 10 BASE-T/
100BASE-TX
Inputs
Operation output
Error output
SC-SL4-AE/SC-SL4-BE
0 ~ 40oC
1 Phase 100-240V 50/60Hz
18W
172mm x 250mm x 23 (+70) mm
2.0kg
up to 128 units
Colour LCD, 9 inches wide
1 systems (Super link- )
8-point pulse width 100ms or more
1 point non-voltage a contact input
continuous input (closed, forced stop)
2 point non-voltage a contact input
continuous input (closed, demand control)
1 point maximum rated current 40mA, 24 V
During full stop; Open. If even one unit is operating; Closed
1 point maximum rated current 40mA, 24 V
Normal; closed. If even one unit is abnormal; Open
An SC-SL2NA-E performs the start/stop control, monitoring and mode setting of up to 64 units. It
is a high quality air conditioner control system that allows up to 64 indoor units to be freely
grouped into 1 to 16 groups.
It allows not only the start/stop control but also the monitoring, display of operation statuses such
as in operation or in need of service and mode setting such as switching of operation modes of
connected units collectively, by group or individually.
Outer dimensions: H120 x W215 x D25+35*mm.
35* is the measurement including the part contained in a recess.
Note:Please consult dealer for combination of center controls and BMS interface units.
74
75
R410A
Production by order
Control and monitoring of up to 96 cells (some cells can have two or more indoor units and total number of
indoor units can be up to 128 units) centralised to a network PC using the Superlink- web gateway. Simple
installation is assured with no special software requirements, operation is via Internet Explorer. A low power
embedded CPU and compact flash ROM ensure a large storage capacity with high reliability (no moving parts
such as a PC fan, etc). An IP address filter function combined with three-level user authentication check also
ensures security.
SUPERLINK-
Internet
Explorer
The design of the outdoor units separates the air flow compartment from
the mechanical compartment, allowing easy access to serviceable parts
by simply removing the panel.
No. 1 system
HUB
48 cells
Ethernet 10 BASE-T/
100BASE-TX
SUPERLINK-
pulse
No. 2 system
64 units
SC-ADNA-E
Mechanical
chamber
Service maintenance and trouble shooting tasks can be carried out easily
via the wired remote controller, as well as a cooling test operation to
assist commissioning.
64 units
48 cells
This design also means that the base plate of the air flow compartment
acts as a drain tray connected to a drain pipe that runs through the
mechanical compartment, so a simple connection of a drain hose to the
base of the unit is all that is required, no need for a separate drain tray to
be installed.
P1
P2
P3
P4
(in case of SC-WGWNB-B)
Cell
The outdoor unit control box is also equipped with a switch to invoke a
'test-run' mode. This function can be used to help detect any installation
errors, indoor/outdoor unit matching errors, EEV and valve operation. A
'pump-down' switch on the PCB allows refrigerant to be recovered with
the compressor protected.
All outdoor unit PCBs are also equipped with a 7-segment digital display
for detailed operation history and fault finding. Operation data is stored
for the 30 minute period preceding a fault occurring and details are
displayed on the 7-segment reading.
Production by order
SC-BGWNA256-A/B, SC-BGWNA-A/B are interface devices that convert MHIs Superlink- communication
data to BACnet code. In case of SC-BGWNA256-A/B, up to 256 cells (some cells can have two or more indoor
units and total number of indoor units can be up to 256 units) are controlled centrally from a BMS.
SUPERLINK48 cells
No. 1 system
64 units
Ethernet 10 BASE-T/100BASE-TX
BACnet I/P Protocol.
48 cells
Network
for
lighting
SC-ADNA-E
SUPERLINK-
No. 2 system
64 units
Emergency
sensor
network
Cell
pulse
P1
P2
P3
P4
(in case of SC-BGWNA-B)
Production by order
SC-LGWNA-A is an interface device that converts MHIs Superlink- communication data to LonWorks code.
Control and monitoring functions of the a/c system for up to 96 indoor units can be integrated to a central
control point via the building management system network.
SUPERLINK-
No. 1 system
48 units
LonWorks network
(FTT-10)
SUPERLINK-
76
Network
for
lighting
Emergency
sensor
network
SC-ADNA-E
Indoor
unit
Indoor
unit
Indoor
unit
Indoor
unit
Indoor
unit
Indoor
unit
No. 2 system
48 units
77
All technical support, including specifying work, compatibility issues, product quality (repair and replacement issues), product liability issues
and the required after sales service (including spare parts supply) will be provided by Intesis as it is an Intesis product.
Product sales and delivery will be conducted by Intesis as well.
For details concerning such matters please directly contact Intesis.
Example :
Device as Master
Example :
Device as Slave
TOUCH SCREEN
TOUCH SCREEN
TOUCH SCREEN
MH-AC-KNX-128
Windows
blinds
Alams
Alams
INTEGRATED GATEWAY
MH-AC-MBS-48
78
Alams
Example :
Device as Master
MODBUS
INTEGRATED GATEWAY
Lighting
Energy
management
RC-E5
Lighting
HVAC
Windows
blinds
HVAC
MH-AC-MBS-128
Energy
management
Example :
Device as Slave
MODBUS
RC-E5
MH-RC-ENO-1i/1iC
Example :
Device as Master
Example :
Device as Slave
RC-E5
Protocol : EnOcean
1i : 868MHz@EU
1iC : 315MHz@USA, ASIA
Dimension : 100 x 70 x 28 mm
External Power supply : no need
URL
email
tel
http://www.intesis.com
info@intesis.com
+34 938047 134
79
R410A
Production by order
Sea breeze
Exterior panel
Base plate
Drain pan
Model No.
FDCS280KXZE1
FDCS335KXZE1
FDCS400KXZE1
FDCS450KXZE1
FDCS475KXZE1
FDCS504KXZE1
FDCS560KXZE1
Fan motor
Sea
4~6HP
Combination systems:22~60hp (61.5kW~168.0kW) are the same as that of the standard KXZ series shown on previous pages.
Specifications and Dimensions are the same as that of the standard KXZ series shown on previous pages.
Non-CE Marking models.
KXZ
8~12HP
Fin
pipe
Side plate
Compressor
Accumulator
Receiver
4~6HP
Heat exchanger
Control box
Baffle plate
8~12HP
4~6HP
8~12HP
4~6HP
8~12HP
Corrosion protection treatment complies with regulation of The Japan Refrigeration and Air Conditioning Industry Association (JRA9002)
Caution
Even if the outdoor unit is protected with the anti-salt damage treatment, it cannot be perfectly free from rusting.
The following points should be kept in mind during installation and maintenance of the outdoor units.
Installation
(1) When installing the outdoor unit close to the coastal area, provide a windbreak to protect it from direct sea breeze and
salt water splash.
(2) Select a well-drained place to install.
(3) If any scratch or damages occurred on the outdoor unit during installation, repair it carefully.
Maintenance
For outside sheet metals, Cation electrodeposition coating is used for undercoat plus polyester powder coating or
acrylic backed coating for top coat and corrosion protection is applied for heat exchanger, welded parts, fan guard, fin
guard and other major parts.
Preventing corrosion by salt damage or sulfurous acid gas has made service life of this series longer while its exterior
appearance has been greatly improved.
Durability of this series for anticorrosion is about two times that of standard outdoor units under the same conditions.
80
(1) Clean salt grains on the outdoor unit with fresh water periodically.
(2) Apply rust preventive at regular intervals for maintenance depending on the conditions at the installation place
(consulting with the withstanding capacity).
(3) Confirm reset of screw tap after maintenance, if missing it may cause corrosion occurred from the hole of screw tap.
(4) During prolonged non operation periods, protect the unit with covering.
81
R410A
DRAFT
Applicable to
1. EER/COP (High efficiency)
Energy saving
Cooling tower
Cooling tower
40m
Height difference
between outdoor
unit and indoor unit
(outdoor unit below)
Refrigeration piping
Indoor unit
Machine room
Height
difference
50m
To the
first branch:
max 130m
Outdoor unit
1. High-rise Building
2. Design Flexibility
Compact design
Easy transportation and installation
Dimensions
8, 10, 12HP
Specifications
Item
Combination (FDC)
Nominal horse power
Power source
Cooling
kW
Heating
Cooling
Power consumption
kW
Heating
EER
Cooling
COP
Heating
Exterior dimensions HxWxD mm
dB(A)
Sound pressure level
kg
Net weight
Nominal capacity
Item
10HP
12HP
22.4
25.0
4.23
4.24
5.3
5.9
28.0
31.5
5.75
5.10
4.9
6.2
1100x780x550
50
150
33.5
37.5
8.13
6.30
4.1
6.0
47
54
224KXZWE1
224KXZWE1
280KXZWE1
26HP
224KXZWE1
280KXZWE1
280KXZWE1
28HP
73.0
82.5
14.2
13.8
5.1
6.0
77.5
90.0
15.5
14.8
5.0
6.1
53
54
280KXZWE1
280KXZWE1
280KXZWE1
30HP
224KXZWE1
280KXZWE1
18HP
280KXZWE1
280KXZWE1
335KXZWE1
32HP
82
224KXZWE1
224KXZWE1
16HP
52
280KXZWE1
280KXZWE1
20HP
280KXZWE1
335KXZWE1
22HP
335KXZWE1
335KXZWE1
24HP
56.0
63.0
11.5
10.2
4.9
6.2
1100x780x550x2units
53
150+150
61.5
69.0
13.7
11.4
4.5
6.1
67.0
75.0
16.3
12.6
4.1
6.0
55
57
VIEW A
Combination (FDC)
Nominal capacity
8HP
280KXZWE1
335KXZWE1
335KXZWE1
34HP
335KXZWE1
335KXZWE1
335KXZWE1
36HP
95.0
106.0
21.7
17.6
4.4
6.0
100.0
112.0
24.3
18.8
4.1
6.0
58
59
Piping size
Mark Content
High/low gas line *1
A
Discharge gas line *2
Suction gas line *2
B
Liquid line
C
Oil equalization line
D
Water inlet
F
Water outlet
G
Drain outlet
H
Power supply intake
J
Signal wiring intake
K
Anchor bolt hole
L
Refer to
piping size.
R1 1/4
R1 1/4
Rp 1/2,2pcs.
35
35
18,4pcs.
FDC-KXZWE1
Dimension
224,280
335
C1
142
139
C2
322
316
Installation
1
example
Dimension
L1
600 or more
L2
20 or more
L3
500 or more
L4
20 or more
L5
300 or more
83
R410A
Model No.
FDCH735CKXE6G (FDCH335-K+FDCH400)
FDCH800CKXE6G (FDCH400x2)
FDCH850CKXE6G (FDCH400+FDCH450)
FDCH900CKXE6G (FDCH450x2)
FDCH960CKXE6G (FDCH450+FDCH504)
FDCH1010CKXE6G (FDCH504x2)
FDCH1065CKXE6G (FDCH504+FDCH560)
FDCH1130CKXE6G (FDCH560x2)
FDCH1180CKXE6G (FDCH560-K+FDCH615)
FDCH1235CKXE6G (FDCH615x2)
FDCH1300CKXE6G (FDCH615+FDCH680)
FDCH1360CKXE6G (FDCH680x2)
FDCH335CKXE6G-K & FDCH560CKXE6G-K are only used for combining with other models.
Specifications
Production by order
Blue
Fin
Blue
Fin
Item
Model
Cooling
Starting current
Power consumption Cooling
Running current Cooling
HxWxD
R410A
Liquid line
Gas line
Capacity connection
Number of connectable indoor units
Item
kW
A
kW
A
mm
kg
kg
Electrical characteristics
FDCH335CKXE6G-K
FDCH400CKXE6G
FDCH450CKXE6G
Exterior dimensions
Net weight
Refrigerant charge
FDCH504~680CKXE6G
Total length:
1000m
To the
first branch:
max 130m
From the first
branch to the
furthest
indoor unit:
90m *1
Max: 10m
Outdoor
unit
Max: 5m
Indoor unit
Indoor unit
Indoor unit
50~100m
50
+43C
53
*2
Max height
difference
between
indoor units:
18m
20
Cooling
10
-5C
*2 In case of less than 50m, the High Head models can not be applied.
In case Indoor unit is higher than outdoor unit, the High Head models can not be applied.
84
Electrical characteristics
Exterior dimensions
Net weight
Refrigerant charge
-10
Cooling
Starting current
Power consumption Cooling
Running current Cooling
HxWxD
R410A
Liquid line
Gas line
Item
30
FDCH960CKXE6G
450CKXE6G
504CKXE6G
34HP
kW
A
kW
A
mm
kg
kg
mm(in)
%
Model
96.0
27.70
45.2-41.3
326+358
Cooling
Starting current
Power consumption Cooling
Running current Cooling
HxWxD
R410A
Liquid line
Gas line
Capacity connection
Number of connectable indoor units
kW
A
kW
A
mm
kg
kg
FDCH800CKXE6G
FDCH1180CKXE6G
118.0
37.16
60.5-55.4
mm(in)
%
69
FDCH850CKXE6G
FDCH900CKXE6G
400CKXE6G
400CKXE6G
400CKXE6G
450CKXE6G
28HP
30HP
3 Phase 380-415V, 50Hz
80.0
85.0
16
22.54
24.24
36.8-33.8
39.5-36.2
1690x2700x720
326x2
11.5x2
19.05(3/4")
31.8(1 1/4") [34.92(1 3/8")]
50~160
58
61
FDCH1010CKXE6G
450CKXE6G
450CKXE6G
32HP
90.0
25.94
42.2-38.6
65
FDCH1065CKXE6G
FDCH1130CKXE6G
504CKXE6G
504CKXE6G
504CKXE6G
560CKXE6G
36HP
38HP
3 Phase 380-415V, 50Hz
101.0
106.5
16
29.46
31.52
48.2-44.0
51.5-47.1
2048x2700x720
358x2
11.5x2
19.05(3/4")
31.8(1 1/4")[34.92(1 3/8")]
50~160
69
59
560CKXE6G-K
615CKXE6G
42HP
Combination (FDCH)
40
20.21
32.9-30.2
Model
Capacity connection
Number of connectable indoor units
Range of operation
73.5
mm(in)
Combination (FDCH)
Nominal horse power
Power source
Nominal capacity
FDCH735CKXE6G
335CKXE6G-K
400CKXE6G
26HP
Combination (FDCH)
FDCH1235CKXE6G
560CKXE6G
560CKXE6G
40HP
113.0
33.58
54.8-50.2
22.22(7/8")
38.1(1 1/2")
50~130
62
66
FDCH1300CKXE6G
FDCH1360CKXE6G
615CKXE6G
615CKXE6G
615CKXE6G
680CKXE6G
44HP
46HP
3 Phase 380-415V, 50Hz
123.5
130.0
16
40.74
45.35
66.2-60.6
73.4-67.2
2048x2700x720
377x2
11.5x2
22.22(7/8")
38.1(1 1/2")
50~130
72
76
680CKXE6G
680CKXE6G
48HP
136.0
49.96
80.6-73.8
80
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Piping length is 7.5m.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
3. [ ] : Pipe sizes applicable to European installations are shown in parentheses.
4. The above data applies to D service code models. Please check service codes for full specification.
85
R410A
Dimensions
Dimensions
Content
Refrigerant gas piping connection pipe
Refrigerant liquid piping connection pipe
Refrigerant piping exit hole
Power supply entry hole
Anchor bolt hole
Drain waste water hose hole
Drain hole
Refrigerant oil equalization piping connection pipe
Carrying in or hole for hanging
86
400
450
25.4(Brazing)
Installation example
28.58(Brazing)
12.7(Flare)
88(or 100)
50 (right . left . front), long hole 40 x 80 (under side)
M10, 4 pcs
45, 3 pcs
20, 10 pcs
9.52(Flare)
230 x 60
Dimensions
L1
L2
L3
L4
H1
H2
H3
H4
500
Open
L3
L2
L5
L6
L1 (Unit front side)
Wall height
H2
10
10
100
100
10
Open
1500
Open
No limit
No limit
1000
No limit
No limit
Open
Installation example
L4
Wall height
H4
Notes:
(1) The unit must be fixed with anchor bolts.
(2) Leave a 2m or larger space above the unit.
(3) The unit name plate is attached on the lower right corner of
the front panel.
(4) The ports for refrigerant pipe and power cable penetrations
are covered with half-blanks. Please cut off a half-blank with
nippers in using these ports.
(5) Use a 88 port for refrigerant pipe connection.
(6) Anchor holes marked L J (four holes for M10) are for a
renewal installation.
(7) The oil-equalising pipe K should be used when outdoor units
are used in combination. (For 14,16Hp only)
335-K
Wall height
H2
Mark
A
B
C
D
F
G
H
K
L
Dimensions
L1
500
Open
L2
10
200
L3
100
300
L4
10
Open
L5
400
L6
400
H1
1500
No limit
H2
No limit
No limit
H3
1000
No limit
H4
No limit
No limit
Mark
A
B
C
D
F
G
H
K
L
Content
Refrigerant gas piping connection pipe
Refrigerant liquid piping connection pipe
Refrigerant piping exit hole
Power supply entry hole
Anchor bolt hole
Drain waste water hose hole
Drain hole
Refrigerant oil equalization piping connection pipe
Carrying in or hole for hanging
Installation example
28.58(Brazing)
12.7(Flare)
88(or 100)
50 (right . left . front), long hole 40 x 80 (under side)
M10, 4 pcs
45, 3 pcs
20, 10 pcs
9.52(Flare)
230 x 60
Dimensions
L1
L2
L3
L4
H1
H2
H3
H4
500
Open
10
10
100
100
10
Open
1500
Open
No limit
No limit
1000
No limit
No limit
Open
Notes:
(1) The unit must be fixed with anchor bolts.
(2) Leave a 2m or larger space above the unit.
(3) The unit name plate is attached on the lower right corner of
the front panel.
(4) The ports for refrigerant pipe and power cable penetrations
are covered with half-blanks. Please cut off a half-blank with
nippers in using these ports.
(5) Use a 88 port for refrigerant pipe connection.
(6) Anchor holes marked L J (four holes for M10) are for a
renewal installation.
(7) The oil-equalising pipe K should be used when outdoor units
are used in combination.
87
R410A
If replacing a used unit with a new one, these units can reuse existing piping.
Nominal Cooling Capacity
22.4kW
28.0kW
Model No.
FDCR224KXE6
FDCR280KXE6
Blue
Fin
1.Implement cooling operation of all indoor units for more than 30 minutes.
2.Implement pump-down after cooling operation.
3.Recover refrigerant and remove the existing outdoor unit and indoor unit.
<Option>
FDCR-KIT-E : Service valve kit
Applies to a wide range of pipe sizes (R22, R407C, R410A standard size).
Meets to a short period of renewal installation.
Savings on replacement expenses such as scrapping waste material or procuring new pipe.
Possible to replace the existing unit with a new larger capacity unit.
Possible to replace plural systems with one system.
For example:Existing 5HP x 2units can be replaced with a new 10HP x 1unit.
5HP x 2
10HP x 1
Outdoor unit
Range of operation
Indoor unit
Indoor unit
Indoor unit
Height difference
50m(outdoor unit above)
40m(outdoor unit below)
7-segment display
Piping system
outdoor unit
+43C
indoor unit
heat exchanger
high
efficiency
strainer
compressor accumlator
Pipe refresh kit
high efficiency
strainer
oil separator
Dimensions
refrigerant flow
50
40
Max height
difference
between
indoor units:
15m
30
20
Cooling
+15.5C
10
0
Heating
-10
-15C
Furthest
indoor unit: 160m
-20
-20C
Specifications
Item
Nominal horse power
Power source
Model
Cooling
kW
Heating
A
Starting current
Cooling
Power
kW
Electrical characteristics consumption Heating
Cooling
Running
A
current
Heating
HxWxD
mm
Exterior dimensions
kg
Net weight
R410A
kg
Refrigerant charge
Cooling/Heating
dB(A)
Sound pressure level
Liquid line
mm(in)
Refrigerant piping size
Gas line
%
Capacity connection
Number of connectable indoor units
Nominal capacity
FDCR224KXE6
FDCR280KXE6
8HP
10HP
3 Phase 380-415V, 50Hz
22.4
25.0
28.0
31.5
5
5.60
6.03
9.25-8.47
9.85-9.02
8.09
8.21
13.22-12.10
13.41-12.28
1675x1080x480
224
11.5
58/58
59/60
9.52(3/8")~15.88(5/8")
19.05(3/4")~25.4(1")
22.22(7/8")~28.58(11/8")
50~130
13
16
1. The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.
2. Sound pressure level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
88
Mark
A
B
C
D
E
F1
F2
F3
F4
G
Item
Service valve connection of the attached connecting pipe (gas side)
Service valve connection (liquid side)
Pipe/cable draw-out hole
Drain discharge hole
Anchor bolt hole
Cable draw-out hole
Cable draw-out hole
Cable draw-out hole
Cable draw-out hole
Connecting position of the local pipe. (gas side)
Notes:
(1) It must not be surrounded by walls on the four sides.
(2) The unit must be fixed with anchor bolts. An anchor bolt must not
protrude more than 15mm.
(3) Where the unit is subject to strong winds, lay it in such a direction that the
blower outlet faces perpendicularly to the dominant wind direction.
(4) Leave a 1m or larger space above the unit.
(5) A wall in front of the blower outlet must not exceed the units height.
(6) The model name label is attached on the lower right corner of the front.
(7) Connect the Service valve with local pipe by using the pipe of the
attachment.(Gas side only)
(8) Mark shows the connecting position of the local pipe.(Gas side only)
89
R410A
/further information
Mitsubishi Heavy Industries operates a continuous CSR (Corporate Social Responsibility) policy, with a role to realise a sustainable society through its
various areas of business.
Creed
In order to make the sustainable development of society possible, a basic policy on environmental matters has been established.
Pursuant to the express provision of Section 1 of its creed that We strongly believe that customers come first and that we are obligated to be an
innovative partner to society, MHI shall, as a matter of primary importance, strive, through its R&D, manufacturing and other business activities, to play
a useful role in the development of society. To this end, while remaining aware that a business enterprise is a member of society, MHI shall endeavour,
in all aspects of its business activities, to reduce the burden on the environment and shall concentrate and fully utilise its technological capabilities for
the development of technologies and products that will protect the environment, thus contributing to the establishment of a society in which sustainable
development is possible.
We strongly believe that the customer comes first and that we are obliged to be an innovative partner to society.
We base our activities on honesty, harmony, and a clear distinction between public and private life.
We shall strive for innovative management and technological development from an international perspective.
In order to realise its basic policy, MHI has set the following seven conduct guidelines.
In Japan there are many enterprises with their own creeds which simply represent their management
concept.
Mitsubishi Heavy Industries, Ltd. has a creed of this type, also. It was instituted in 1970 on the basis of
the policy advocated by Koyata Iwasaki, president of Mitsubishi Goshi Kaisha in the 1920s, to indicate
the essential attitude of the company, the mental attitude of the employees, and the future directions of
the company.
The reason for instituting the present creed is so that all of us can call to mind our one hundred years of
tradition, and strive for further development in the future.
Contribution to
Society through
Company Business
Environment,
Human Rights
and Labour
MHIs creed was established based on The Three Corporate Principles shared by the Mitsubishi Group
from the companys beginnings. In the spirit of this creed, MHI continues its efforts to fulfil its three
corporate social responsibilities (CSRs): corporate governance and compliance, the environment, human
rights and labour, and contribution to society through business activities.
Transportation
& Security
MISSION
MISSION
VISION
2. Define roles and responsibilities regarding environmental protection by developing and maintaining a corporate organisation designated for environmental
protection, and create and implement corporate policies and procedures on environmental matters.
3. Endeavour to reduce the burden on the environment by preventing pollution, saving resources, saving energy, reducing waste, reusing materials, and recycling
in all aspects of the companys business activities in R&D, designing, procurement of materials, manufacturing, transportation, use, service and disposal.
5. Comply with national and local environmental laws and regulations, beyond mere compliance by enacting, implementing and evaluating voluntary
standards where necessary, and to endeavour to continuously improve and promote environmental protection activities by establishing environmental
goals and targets.
1. Recognise that environmental protection is top priority in the companys operations, and encourage the entire company in its endeavours to protect and
improve the environment.
4. Endeavour to develop and provide advanced, highly reliable, unique technologies and products that contribute to solving environmental and energy problems.
The KXZ product range has been developed in compliance with the Mitsubishi Heavy Industries Policy on the Environment.
6. Endeavour to protect the environments of foreign countries by carefully examining the consequences of the companys overseas business operations and
the exportation of its products, and to become actively involved in technological co-operation overseas in areas of environmental protection.
7. Provide environmental training and other programs to enhance the environmental awareness of all company employees, and take steps to expand public
relations activities, such as providing environment-related information to the public and social contribution activities.
as of May, 2013
Europe
Major subsidiaries
18
Environment
& Society
MISSION
Help people lead
fulfilled lives
90
Major subsidiaries
Japan
Asia
Major subsidiaries
Industries
MISSION
Support manufacturing
activities worldwide
66
10
Works
14
29
6
129
Africa
Major subsidiary
Oceania
Major subsidiaries
91
global activity
On the land and sea, in the sky and even in space,
MHIs stage of operations is expanding limitlessly.
We manufacture more than 700 different products which
support various industrial and civil activities in both domestic
and international markets.
Ships, steel structures, power systems, machinery for
both industrial and general use, air-conditioners, pollution
reduction and environmental control systems, aerospace
systems the MHI product lines which create rich and
comfortable living environments, are as harmonious as
an orchestra.
Chemical Plants
Wind Tunnel/Experiment
Equipment
Casting Machines
Strip Mill
Cement Plant
Stepless Variable Speed Gears
Industrial Robots
Injection Moulding Machines
Pulp & Paper Machinery
Corrugation Machines
Box Making Machines
Machine Tools
Cable Layer
Printing Machinery
EM
SY
ST
STY
L
IO
NT
AT
IFE
E/L
IN
FO
RM
SU
R
LEI
TRIAL
INDUS
RGY
S/ENE
URCE
RESO
EN
TIO
N
ME
ON
TA
VIR
OR
EN
SP
PM
LO
VE
AN
DE
TR
AL
92
C
LO
Oceanographic Research
Ships
Deep Submergence Research
Vehicles
Communications Satellite
Rockets
Space Transportation
Rockets & Engines
EL
V
DE
E
PM
CE
N
EFE
Submarines
Naval Vessels
Jet Fighters
Helicopters
Missiles
Tanks & Infantry Fighting
Vehicles
93