(TOTAL 48 SHEETS WITH COVER)PART IV_ELECTRIC SPECIFICATION
SHCTION 1 - ELECTRIC INSTALLATION IN GENERAL
1d
ie
1.3
14
1.5 COLORS ..
1.6 TESTINGS AND TRIALS
SHC CABLE IN (ONS
2.1 ELECTRIC CABLES .
2.2 CABLE INSTALLATIONS ....00...eeceeceeeeeee 6
SECTION 3 - ELECTRIC GENERATORS
3.1 MAIN GENERATORS 60.0.2... cece cceeeeeeetttttsseeeeeenes E-7
3.2 EMERGENCY GENERATOR .. 9
ON 4 = TRANSFORMERS AND BATTERIE:
4.1 TRANSFORMERS E-u
4.2 STORAGE BATTERIES 6220... eee ceeeeeeeeceesesssseeeeernavees B-u
SECTION 5 -_ SWITCHROARDS
I CEN D AL eee eee eee eee B- 1
5.2 MAIN SWITCHBOARD ....... -B- 13
idee ENEHGRNCT| SW UTCHBOARD ferent tye tcteaet te see ete eee vB
5.4 SHORE CONNECTION EQUIPMENT ... -B- 16Page
Se = ELECTRIC DISTRIBUTION
Grip ELRCTRIC DISTRIBUTION ee re seme eee ene ee tet tt ve B= 16
6.2 DISTRIBUTION PANELS... ce cee eeeeeeeeeeetereeeeeeeeeeteeeeees B- 16
SECTION 7 - MOTORS AND STARTERS
7.1 MOTORS
7.2 STARTERS ..
SECTION 8 — BQUIPMENTS. HERS
8.1 HEATING BQUIPMENTS AND DOMESTIC SERVICES ........00000eseeeseeereeee B- at
8.2 MACHINE TOOLS 0.0.0... eeeegseecseeeeeessseeeeveveteeeeeeesettnaate B-a
8.3. RECEPTACLES ......... B- 2h
8.4 OIL HEATERS ............ Ce ee eer
8.5 WIRING OF ELECTRIC WELDERS 0.0... 2.2... ceeeeeeeeceeeeeeeee B- a1
CTI ELECTRIC LI
9.1 BLECTRIC CIRCUITS FOR LIGHTINGS .. B- 22
9.2 LIGHTING FIXTURES AND OUTLETS B- 22
2lr3 pee EIGHE ENG INSTALLATIONS tesserae ene tne ete eee B- 23
9.4 NAVIGATION LIGHTS 56.2.2... eect eeeeseeteeeeeneeeee cere re etc5)Page
SBCTIL ILECTRIC INTERIOR COMMUNI! EQUIPMENTS
10.1 TELEPHONE EQUIPMENTS 0.0.0.0... csccceeeeeeeetteteeeeenteeee ss E> 26
10.2 CALL SIGNAL BELLS .. B- 28
10.3 GENERAL ALARMS EB 28
10.4 ENGINEER'S ALARMS .......... EB - 28
10.5 RUDDER ANGLE INDICATORS .... -E- 28
10.6 AIR HORNS . 1 B- 29
10.7 FIRE DETECTING SYSTEM... 0... -B- 29
10.8 ELECTRIC CLOCKS . -E- 29
SECTION 1 JBCTRIC NAVIGAT JUIPMEN
11.1 GYRO COMPASS AND AUTO PILOT E- 30
11.2 WIND DIRECTION AND SPEED METER ... B- 30
11.3 ECHO SOUNDER... e eee E- 30
11.4 CLEAR VIEW SCREENS AND WINDOW WIPERS ........00000eseceseeecsesaees g-31
ie Sy DOPPLER LOG ee reel tte yet eee ee B- 31
11.6 NAVTEX RECEIVER -......0600eeeeeeeee B- 31
SECTION 12 - RADIO BOU s
12.1 RADIO TELEPHONE B- 32
12.2, V.HLP. RADIO TELEPHONES ......... B- 32
12.3. SATELLITE E.P.1.R.B..., +B 33
12.4 TWO-WAY V.H.P. RADIO TELEPHONE APPARATUS (150MHZ) ..........000000.. B- 33
12.5 U.H.P. ONBOARD COMMUNICATION APPARATUS (400MHz) (OWNER SUPPLY)...... B - 33
#12 Ge RADAR) TRANGPOBDERS ey eet tee) geet eet eet ee +E 33
12.7 SATELLITE COMMUNICATION SYSTEM (INMARSAT-C) .....0000cceeceeecceeee B= 33
12.8 SATELLITE COMMUNICATION SYSTEM (INMARSAT-F) ........ E- 33‘SECTION 13 - ELECTRONIC EQUIPMENTS
13.1 RADARS ....
13.2. DIFFERENTIAL GPS NAVIGATOR
13.3. WEATHER FACSIMILE RECORDER
13.4 AIS (Automatic Identification System) ..........00cc cece B- 35
13.5 VDR (Voyage Data Recorder) . B- 35
13.6 SSAS (Ship Security Alert Systen) B- 35
CTION 14 = PUBLI SSSORS_AND_NISCELLANE 1.0 EQUIPMENTS
14.1 PUBLIC ADDRESS SYSTEM + B- 36
14.2 TSLEVISION/BROADCASTING RADIO ANTENNA AND TELEVISION.........00.2... E- 36
SECTION 15 - SPARE PARTS AND_OUTEITS
15.1. SPARE PARTS veer B= 87
15.2 OUTFITS -B- 39PART IV
ELECTRIC SPECIFICATIONSMl
12
SECTION 1 - ELECTRIC INSTALLATION IN GENERAL
GENE!
‘The electric equipments, machinery and installations to comply with the Rules and Regulations
specified in General Provisions of the Specifications and/or Japan Blectrical Comittee
Standard (JBC) and/or the standard of the Japan Electrical Manufacturer's Association (JEM)
and Builder’s standard,
VOLTAGE, FREQUENCY AND DISTRIBUTION SYST!
In general, voltage, frequency and distribution for electric equipments to be employed as
follows :
ten Voltage Frequency Phase Conductor
Generators AcESOV 6H 36 3 wires
Power motors ACKOV 60H 3¢ 3 wires
Do. (fractional horse AcLOOv 80H 3¢ or 3 wires
power and special service) 1g 2 wires
Electric range and oven acA4ov 60H 36 3 wires
Heating AceOV 60H 36 3 wires
and/or
AcLOOV ig 2 wires
Lighting ACLOOV 60H lp 2 wires
Nautical equipnents acasov 602 36 3 wires
and/or
AcioOv 16 2 wires
and/or
peasy a 2 wires
Interior communications, ACLOOV 602 16 2 wires
general alarms, etc. and/or
peeay - 2 wires
Radio equipments aceaoy 60H 3¢ 3 wires
and/or 5
ACLOOV 16 2 wires
and/or
peaay a 2 wires
Entertainment equipments actoov 6oltz 1g 2 wires
Energency Lights ActOOv 602 16 2 wires
Automation instrunents acioov 60H 16 2 wires
and/or
Deeav - 2 wires1.3
14
sTS_AND_TERMINAL:
1.3.1 Sockets
In general, type and size of sockets for lamps to be as follows, but the sockets for
fluorescent, Laups to be of bi-pin type (spring type).
‘Type Size
Pilot lamps in main switchboard Edison u
or Manufacturer's
standard
Pilot lamps in starters
(acisv) Bison 2
(neaav) Bayonet 8
or Manufacturer's
standard
Lighting fixtures
(300W and over) Baison 29
(2504 and below) Baison 6
Mercury vapor lamps
(300W and over) Baison 39
(250W and below) Edison 2B
Pilot lamps for communication Manufacturer’ s
equipments, nautical and radio standard
equipments
1.3.2 Terminals
In general, type of temminals to comect the outgoing cables to be as follows :
Tue
Lighting fixtures, switches, Snall electric terminals
Branch boxes, etc. (18 type)
Other mentioned Solder less type
FUSES
Fuses to be of non-renewable cartridge types approved by the Classification Society shall be
installed
Special type fuses for electronic equipments to be of manufacturers’ standards.1.5
1.6
COLORS
1.5.1 Electric Bauipments
Final painted colors of netal surface for electric equipnents to be
Munsell No.7.586 7/2 (Light green) except as follows :
Munsell. No,
Scanner for radars N+1 (gray)or
Manufacturers’ standard
General alarms and 5R 4/13 (red)
other exergency equipments
Electric equipments of Manufacturers’ standards
foreign make (if installed)
Metal surface inside of electric equipments to be painted by manufacturers’ standards
colors.
1.5.2 Bus bars
AC. system D.C. system
Phase R or U Positive (+) +++
Phase $ or V +++ Negative (-) -++++++++-Blue
Phase T or W
TASTIN TALS
In general, the shops and/or on board tests for all electric equipments to be carried out in
accordance with the Rules, Regulations and the Builder’s standard as follows and also attended
by Owner's Representative and Classification Society’s surveyor where found necessary.
1.6.1 Shop Trials at Manufacturers’ Plants
a) Generators and/or vital motors
Pull load temperature tests
Characteristic tests
Over speed tests
High voltage tests
Insulation resistance tests
‘The load of generators test to be in accordance with the Rules of the Classification
Society and/or Japan Electric Comittee Standard(JEC)and/or the standard of the Japan
Electrical Manufacturer’s Association(JEM)
After the above tested, generators to be coupled with the prime movers afd tested
according to the manufacturers’ standard.1.6.2
b) Switchboards
‘Temperature tests
High voltage tests
Meter calibrations
Function test
Insulation resistance tests
Protective device tests for air circuit breakers
c) Other electric equipments
In general, electric equipments for vhich the Rules or Regulations are not
applicable to be tested in accordance with the manufacturers’ standards.
On _board testing
Automatic starting tests for emergency generator and all electrical equipnents and
installations to be tested in accordance with the Builder’s standard and class
requirenents.
a) Main generating sets
Individual running tests
Governor tests and voltage regulation tests
Parallel running test
Automatic and remote starting confirmations
Black-out tests
bv) Bnergency generating set
Running test
Governor test and voltage regulation test
‘Auto starting confimation
Nain and emergency generating sets to be tested with water resistance load at dock
side, and actual load at sea trial.
c}) Main and emergency switchboards
Air circuit breaker trip tests
d) Motors and starters
Satisfactory operations to be confirmed on sea trial or dock side
e} Nautical end interior communication equipments
Normal operations or calibration to be confimed on sea trial or dock side
£) Other electric equipments
Other electric equipgents to be confirmed before delivery.SECTION 2 - CABLE INSTALLATION
RIC_CABLES
ALL cables to be approved by the Classification Society and Japanese Industrial Standard (JIS)
and of 0.6/1kV or 250V grade insulation to meet the voltage to which they are subjected
The cables application to be as follows:
In general, cables in all spaces, except otherwise specified, to be of ethylene propylene rubber
insulated, polyvinyl chloride (PVC) sheathed and steel wire braided (PYC) with under mentioned
exceptions.
Cables in refrigerating provision stores and weather exposed-spaces except where their lengths
are within about 1 meter to be with outer polyvinyl chloride (PVC) covering.
Cables installed in high temperature spaces where ambient temperature exceeds 70°C to be
insulated with silicon rubber, sheathed with lead and braided with steel’ wire,
Cables which will be affected by any noise to be sealed with transducer chloride,
Special cables such as coaxial cables, compensating cables, shielded cables, fire resisting
cables, etc. to be used where necessary.
Kind, size, etc. of cables supplied by manufacturers together with electric equipments to be
in accordance with the manufacturers’ standardsi]
CABLE INSTALLATIONS
Ingeneral, cables running in groups to be supported with netal hangers and bunched with tubular
bands as far as practicable and are so arranged as to permit painting of the surrounding structure
without undue disturbance
‘The cables, exposed to any mechanical danage, to be protected with steel plates, steel conduits
or flexible tubes (plica tube)in accordance with the Builder's practice.
Cables between deck house and upper deck fore part to be wired inside galvanized steel pipes
(SGP) led on upper deck with pipe expansion joints (dresser type) and cable expansion boxes
with drain holes.
ALL cables passing through weather decks or watertight bulkheads to be provided with watertight
glands, deck tubes or coamings filled up with special compounds and the cables passing through
other decks to be provided wi th deck tubes or coamings in accordance with the Builder's practice.
Wiring throughout the vessel shall be carefully arranged to eliminate fire risks.
In principle, in living quarters, the cables to be fitted inside the wood casings or walls as
far as possible for cabins and places where joiner linings to be carried out.
‘Type and material of cable bands to be in accordance with the Builder’s practice.
Cables to be fixed to the hanger by the binding tapes of galvanized steel or equivalent with
suitable Lining for cables in the machinery spaces, accommodation spaces and store spaces, and
by the binding tapes of stainless steel with suitable Lining for cables exposed to weather.
ALI cables to be so installed that they are not subject to tension or chafing due to the working
of the ship’s structure.
Cable runs to be laid on accessible position for easy maintenance.
Attention to be so paid that the cable runs should not be exposed to water, oil, oily vapor,
steam or excessive high temperature.
Cables along fore mast to be protected with galvanized steel pipe up to Sn height,
on the deckSECTION 3 -
3.1 MAIN GENERATORS
3.1.1 Particulars
‘Type
Enclosure
Rotor
Cooling system
Rated output
Voltage
Frequency
Phase
Power factor
Revolution
Rating
Exciting system
Insulation
No. of sets
3.1.2 Constructions
ELECTRIC GEN! IR
Horizontal, Synchronous
Enclosed drip-proof
Salient pole type
Air self-venti lated
440KW (55ORVA)
AcasOV
60H
3¢
0.8 at lagging
00min!
100% loading continuous
Brush less self exciting
Class F
2
‘The bearings to be of the single end bracket type bearings in accordance with
manufacturer's standard.
Self oil ring lubrication system to be applied depending on manufacturer's standard.
Bearing to have a thermoneter of liquid in glass type and oil sight in drain side.
Air filters to be provided in suction side.
3.1.3 Space Heaters
Sheath wire type space heaters without thermostat to be provided in the frame of each
Generator to prevent the condensation of moisture when the generators are idle, and
fed from ACLOOV source and interlocked with generator's air circuit breakers.
3.14 Exciting Systems
Brush less type exciters to be installed for each generators.B15
3.18
3.19
Characteristics .
Main generator sets to be able to run in parallel
‘The voltage regulation of the main generators to be maintained in the range of 2.5%
of rated voltage between zero to full load under steady condition of rated power
factor.
Maximum voltage change not to exceed 15% when a current equal to 80% of the full load
current at power factor between zero and 0.4 lagging is suddenly drawn.
The voltage to be restored to within 3% of the rated voltage in not more than
0.5 second.
Governor Motors
‘The governor motors to be electrically operated and controlled from the main
switchboard.
Services
‘The main generators to be served as follows:
Service conditions No. of sets in service
At normal sea going One (1)
At leaving & arriving port ‘Two (2)
At cargo handling ‘Two (2)
In port One (1)
Prime Movers
Refer to Machinery Specifications
Netho
Refer to Machinery Specifications.3.2 EMERGENCY GENBRATOR
4.2.1 Particular
Prize mover Diesel engine
‘Type Synchronous
Enclosure Seni-enclosed drip-proof
Cooling system Air self-ventilated
Rated output 80k (100KVA)
Voltage AcASOV
Frequency 60Hiz
Phase a6
Power factor 0.8 at lagging
Revolution 1,800nin?
Rating Continuous
Exciting system Brush less self exciting
Insulation Class F
No. of set 1
‘The prime mover to be of air cooled type diesel engine with starting cell motor and
battery.
‘The accessories and materials for generator engine to be manufacturer's standard.
3.2.2 Control of energency generator
Energency generator to be installed in emergency generator room and to be started
automatically by black-out. condition.
When main source fails, the energency generator to be automatically started and ACB
automatically closed within 45 seconds.
‘when main source recovered, disconnection of the ACB, connection of bus-tie breaker
i.e. conection of emergency loads to main source, and stop of engine to be carried
out by hand.
3.2.3 Characteristics
The voltage regulation of the esergency generator to be maintained in the range of
3.5% of rated voltage between zero to full load under steady condition of rated power
factor.
Maximum voltage change not to exceed 15% when a current equal to 80% of the full load
current at power factor between zero and 0.4 lagging is suddenly drawn.
The voltage to be restored to within 4% of the rated voltage in less then 5 seconds.3.24 Service
The rated out-put is enough to supply the following emergency loads in accordance
with SOLAS regulations.
Steering gears and auto-pilot (one set only)
Main air compressor
Radio equipments
Gyro compasses
Buergency fire pump
‘Transfomer for energency use
Navigation and signaling lights
Bnergency lighting systen
Interior commnications and nautical equipaents
Battery charging and discharging board
No parallel operation with main generator(s) nor sbore to be kept end no power to
be supplied fron energency switchboard to main switchboard
3.2.5 Operation in dead ship condition
‘The emergency generator is to supply main air compressor in dead ship condition in
onder to restore main source of electric power within 30 minutes after black-out
in accordance with SOLAS regulations.
B- 104
4.2
SECTION 4 - TRANSFORMERS AND BATTERIES
"RANS FORMERS:
‘The transformers to be installed as follows
Each transformer to be 60 Hz, dry type, air cool by natural circulation and to have class H
insulation.
For general service transformer to be connected delta-delta for three phases operation.
Voltage
No. Capacity —Pri./Sec. Phase Location
(kVA) Ww)
‘Transformer for 3 25 450/105 1 Engine control room
general service
‘Transformer for 3 15 450/105 1 Energency generator
energency service room
When one (1) transformer is out of service, the other two (2) transformers connected in
V - V-shall be able to supply necessary power under load control.
\GB_ BATTERIE:
4.2.1 Storage Batteries
‘The secondary lead-acid type batteries to be installed as follows;
No. of sets Capacity Voltage Location
(aH) (v)
Battery for 1 200 4 Battery room
general service :
Battery for 1 200 4 Battery room
radio equipaents
Battery for 2 120 ey uergency
emergency generator generator room
starting
Batteries to be contained in Neo-Lunber boxes and installed in battery room and
emergency generator room,
4.2.2 Charging Devices
One (1) set of charging and discharging panel for general service battery to be
Located in nav. locker, and its charging method to be of float-charging type.
One (1) set of battery charging panel for radio equipment of manufacturer’s standard
type to be located in radio space.
One (1) set of battery charging panel for starting battery of emergency generator’s
engine to be located in emergency switchboard.
E-i5.
SLL
5.14
E
SECTION 5 - SWITCHBOARDS
Constructions and Installations
‘The switchboards to be of dead front and self standing type and to be made of steel
frame work,
‘The switchboard to be provided with storm rails on both front and rear of the main
switchboard.
Movable type drip-proof covers to be provided on the rear face of the main switchboard.
Neters
Meters mounted on the front panel of the switchboands to be of the seni-flush type
with accuracy of 1.5 class according to JIS C1102.
Generator Air Circuit Breakers
‘The air circuit breakers for main generators to have long time over current. trip,
instantaneous trip, short time delay trip, under voltage trip and reverse power trip.
Bach air circuit breaker to be provided with interrupting capacity against short
circuit current, and to be of motor drive operation.
Fixed type air circuit breakers to be adopted for main generators and the disconnecting
switches to be provided.
‘The air circuit breaker for energency generator to have long time over current trip,
instantaneous trip, short tire delay trip and hand drive operation.
Feeder Circuit Breakers
Molded case circuit breakers with inverse time thermal trip and instantaneous magnetic
trip features to be provided for AC440V and ACIOOV outgoing circuits.
Molded case circuit breakers to be of plug-in type
B- 125.2
MAIN SWITCHBOARD
‘The main switchboard, located in engine control room, to consist of generator
panels, ACM40V feeder panels and ACLOOV feeder panel.
Insulating mats to be provided for main switchboard front and rear side.
‘The following instruments to be installed on the main switchboard.
5.2.1 Generator Panels
On each generator panel:
1 ~ Air circuit breaker
1 - Air circuit breaker close indicating lamp
1 - Air circuit breaker open indicating lamp
1 ~ Generator space heater switch with close indicating lamp
Each 1 - AC voltmeter and selector switch
Each 1 - AC ameter and selector switch
1 ~ Indicating wattmeter
1 - Governor motor control switch
For total generator sets:
Each 1 ~ Synchronous scope and switch
Fach 1 - Frequency meters and select switches
Generator Monitoring and Control System (JACOM-22 equivalent)
Included autonatic synchronous and load balance device
Bach 1 - Main bus bar monitoring function
Each 1 - Generator monitoring function
Each 1 ~ System monitoring function
Each 1 - Generator engine monitoring function
Each 1 - Generator operation/control function
Each 1 - Generator engine operation/control function
5.2.2 ACAMOV Feeder Pane]
Molded case circuit breakers for all feeder circuits
1 ~ Pilot lamp for shore connection
1 ~ Insulation resistance meter (Mo)
5.2.3 ACIOOV Feeder Panel
Nolded case circuit breakers for all feeder circuits
Each 1 - AC voltmeter and selector switch
Each 1 - AC ameter and selector switch
1 ~ Insulation resistance meter (Ha)
B-135.3
EMBRGENCY SWITCHBOARD
‘The energency switchboard located in emergency generator room to consist of generator panel,
ACH4OV feeder panel, ACIOOV feeder panel and starting battery charging panel
Insulation mat to be provided for energency switchboard front only
‘The following instruments to be provided on the energency switchboard.
5.3.1 rator pane]
1 - Air circuit breaker
1 ~ Air circuit breaker close indicating lamp
1 ~ Air circuit breaker open indicating lamp
1 ~ Generator engine running indicator laap
1 ~ Generator engine stand-by laxp
1 ~ Generator space heater switch
1 ~ Generator space heater close indicating lamp
1 = Automatic voltage regulator
Each 1 ~ AC voltaeter and selector switch
Each 1 ~ AC ameter with a selector switeh .
1 - Frequency meter
~ Indicating wattmeter
~ Auto. / Manu. change over switch
~ Generator start/stop switch
~ Start failure indication lamp
~ L.0. low pressure indication lamp
Over speed indication lanp
- P.O. leakage indication lamp
~ Gylinder head high temperature indication lamp
~ Brergency generator stand-by lanp (on engine control console)
~ Buergency generator rumning lamp (on engine control console)
~ Buergency generator abnormal alarm lanp (on engine control console)
5.3.2 ACMOV feeder pane]
Nolded case circuit breakers for all feeder circuits
5.3.3 ACIOOV feeder panel
Nolded case cireuit breakers for all feeder circuits
1 ~ AC voltmeter
1 AC ammeter
1 ~ Insulation resistance meter (Ma)
B- id5.4 SHORE CONNECTION EQUIPMENT
One (1) set of ACA4OV 60Hz, 3, 400A, drip proof type shore connection box with molded case
circuit breaker, phase sequence indicators (2 lamps type) to be installed.
‘The shore connection box to be provided in energency switchboard
Power available indicating and interlocking device to be fitted in main switchboard as to prevent
the parellel running of each generator with shore power.
Shore connection cabtire cables not to be supplied.
B- 156.1
6.2
SECTION 6 - ELBCTRIC DISTRIBUTION
DISTRIBUTION
In general, power for lange motors, group starter panels and large heaters to be supplied from
ain switchboard directly and other small power consuming devices to be supplied through
distribution panels from the main switchboand.
Power for ACLOV lighting and heating system to be supplied from transformer as specified on
“Paragraph 4.1 TRANSPORMARS” and circuits from main/ewergency switchboard to distribution ‘
panels to be 36-3 wires system, and from distribution panels to lighting fittings or heating
equipments to be 16-2 wires system.
DISTRIBUTION PANELS
Bvery distribution panels to be protected by steel case
‘The front door to have an efficient latch of substitute type
Distribution panels to have necessary components
B- 16TA
TLL
TL
Teg)
Td
SECTION 7 - MOTORS AND CONTROLS
General
In general, the motors to be of squirrel cage, induction type and to operate on 440V,
3, 60Hz, AC source, and the motors less than 0.4kW and domestic service motors to
operate on 440V or 100V, 16 or 3@AC source integrated in auxiliary: machine
manufacturers’ standards.
‘The donestic service motors and special motors such as galley commissary equipnents,
laundry machines, air conditioners, refrigerated provision machines, etc. to be as
per manufacturers’ standards, reganding insulation, construction, enclosure, etc.
Rating
‘The motors to have continuous rating except those specified here under.
Steering gear 1 hour at 100 % load
continuous rating at 50 % load
Tool grinder 1/2 hour at 100 % load
Nain engine L hour at 100 % load
turing gear
Overhead crane 1/2 hour at 100 % load
Insulation
In general, motors smaller than 22 kW,4p and 15 kW,6p to have class B insulation,
and motors larger than 30 kW, 4p and 18.5 kW, 6p to have class F insulation except
‘where special motors integrated in auxiliary machines to be in accordance with
manufacturers’ standards.
Enclosed
In general, motors smaller than 55 kW 4p and 45 KW 6p to be of totally enclosed fan
cooled type with protection IP44, and aotors larger than 75 kW 4p and 56 kK 6p to
be of semi-enclosed drip-proof type with protection IP22 except where special motors
integrated in auxiliary machines to be in accordance with manufacturers’ standards.
‘The motors for vertical axial flow fans (built-in wotor type) and tool grinder to
be of totally enclosed type.
E-11.8
Bearings
In general, bearings to be interchangeable with the Intemational Standard one,
The bearings to be of sealed bearing and/or open bearing with grease nigple (pin type)
in accordance with manufacturers’ standanis.
Anti-coupling side of steering gear motors to be provided with two angular contact
type bearings placed back to prevent fron fretting corrosion by vibration and also
to absorb the shaft expansion during operation.
7.1.6 Speed Changing
‘The motors to be of single speed.
7.1.7 Space Heaters
Space heater to be provided to the motor for energency fire pump, steering gear, deck
cranes.
71.8 Particular of Motors
4s for particular of motors, refer to Hull and Machinery Specifications.
TERS
7.2.1 General
In general, the starters to be of drip-proof and the cabinets to be arranged for vall
and/or floor mounting type.
The starter cabinets to have no interlocking devices with the opening door.
‘The starters in group control panels to be provided with remote start/stop push button
switches with stop locking device without running lamps in vicinity of notors.
But the starter in vicinity of motors to be provided without above mentioned push
button,
‘The starters for all motors to be of magnetic across-the-line starting type except
emergency fire pump, nain air compressor and 45 kW over motors which to be of reduced
voltage starting type.
‘The starters to have under voltage protection, and the under voltage release device
to be equipped on the starters for steering gear
‘The control circuits in starters to be of 440V, but the control circuit which comects
to signal lights selector switches, renote push buttons and relays to be mounted
transformer in each starter for manufacturers’ standards voltage.
‘The over-current protection to be provided in two (2) phase and to be of manual reset
type in controller
‘The over-current protection for steering gear to be of auto reset type.
B- 18ALL overload protective devices to be of the thermal type which is compensated for
changes in anbient tenperature.
Generally, each starter to be contained the following device.
Disconnecting switches
Pilot lamps for source
Nagnetic contactors
Overload relays of thermal trip type
Start and stop push button switches
Ameters (for vital motors for propulsion 7.5 kW and above)
Ruming indicating lamps
However, starters for motors less than 0.4 ki to be contained a discomection switch
only.
Molded case circuit breakers to be used in front of the disconnecting switch for group
starters.
In case of floor mounting type group starter panels, both the maintenance and cable
connections are possible at the front of it.
Steering gear motors to be operated both by push buttons on starters in steering gear
room and by push buttons separately installed in wheelhouse,
‘The following indications and alarms for steering gear to be fitted in the wheelhouse
and engine control room.
Bunning indication
No volt alarm
Over load alam
Phase failure alarm
Low level alarm of oil tank
No.1 motor for steering gear to be fed from the main switchboard and No.2 motor to
be fed from the emergency switchboard (No.2 to be fed from the main generator through
energency switchboard normally, and from the energency generator when main source
fails).
‘The circuits to te separated throughout their length as widely as practicable.
The starters for domestic service motors and special motors such as galley and
commissary equipnents, laundry machines, air conditioners, refrigerated provision
machines, etc. to be as per manufacturers’ standards.
B-197.2.2 Automatic Start and/or Stop
Automatic start and/or stop control gears to be provided with automatic-manual
selector switches mounted on the starters.
Automatic change over control gears to be provided with a stand-by unit selector
switches mounted on the starters.
As for detail, refer to Nachinery Specifications.
7.2.3 Buergency Stop Switches
Energency stop push buttons for engine room ventilating fans, fuel oil transfer pumps,
fuel oil burning pumps and other similar oil pumps to be located at near the engine
room entrance.
Bnergency stop push buttons for accommodation ventilating fans to be located in
‘wheelhouse
B- 208.1
8.2
8.3
84
8.5
SECTION 8 - HEATING EQUIPMENTS AND OTHERS
HEATING EQUIPMENTS AND DOMESTIC SERVICE .
Electric power of ACLOOV to be supplied for laundry, galley, domestic service motors and heaters
except 0.5 kW and above motors and § kW and above heaters.
Electric range and the above exception of motors and heaters to be fed from ACA£0V source.
As for details of above mentioned equipment refer to Hull and Machinery Specifications.
\CHINE TOOL
Machine tools to be fed from ACS40V or ACIOOV source.
Details to be as specified in Machinery Specifications.
RECEPTACLES
Receptacles having the rated capacity of 1A at ACIOOV to be installed as follows:
Non waterproof Waterproof .
Officer’s mess room 6 Engine room about 10
Officer's snoking room 3 Steering gear room 1
Crew's mess & rec. room 1 Inside of funnel 1
Wheelhouse 10 Boatswain store 2
Engine control room 3 Air conditioning unit room 1 '
Galley 10 Huergency generator room 1
Inmer passages each | or 2 Oe bottle room 1
Each cabins about 2 Cargo hold around each 4
Ship's office 4
Receptacles having the rated capacity of 154 at ACAOV to be installed
as follows: boatswain store, deck houses (P only) for each 1.
OTL HEAY .
Oil heaters to be fed from AC440V source.
Capacity to be as specified in Machinery Specifications.
WIRING OF ELECTRIC WELDERS
Electric welders to be fed from AC440V source.
Capacity to be as specified in Machinery Specifications
Wiring of primary side to be fitted in engine work shop, and boatswain store '
B- aSECTION 9 - ELECTRIC LIGHTING
9.1 BLECTRIC CIRCUITS FOR LIGHTING 7
Lighting source of ACIOOV to be supplied from the general /energency transforners.
In general, the circuit to be fed separately to the engine room and accommodation spaces
The electric circuits of engine room to be divided to two (2) system,
‘The energency lights to be fed from the energency switchboard.
9.2 LIGHT! XTURES AND
In general, unless otherwise noted, Lighting fixtures and accessories to be as follows;
Water-proof type and/or Outside spaces exposed to sweat and weather, stores,
drip-proof type galley, pantry, lavatories, bath rooms, engine room
and steering gear room
Explosion-proof type Paint store
Battery room
In general, unless otherwise noted, the ship to be Lighted by incandescent and/or fluorescent
type lighting fixtures as follows:
Fluorescent type Each cabin WiheeLhouse
Inner passage ways Chart space
Radio space Hospital
Galley Pantry
Offices Steering gear room
Engine room Engine work shop
Engine control room,
Stores and cuter passages
Incandescent type Engine room (Partially) and other spaces
All plugs and receptacles to be of 3P type except special service.
‘The fixtures and outlets to be fed from ACLOWV source except otherwise noted, and those material
which are installed to be according to Builder’s standard
E- 229.3
LIGHTING INSTALLATION
9.3.1
9.3.2
9.3.3
9.34
Lighting of A tion Spact
In general, fluorescent type ceiling lamps with globe to be instal led in living rooms :
and common use rooms.
One (1) 15W fluorescent type desk lamp to be installed for desk and each berth in
each cabin respectively.
One (1) 8W fluorescent type mirror Light to be installed for the airror on
wash basin in each cabin and private lavatory, respectively.
‘Two (2) GOW incandescent type chart table lamps with dimmer switches to be
installed for chart table.
Passage Lis
Incandescent type Lights with guard and globe to be installed for accommodation outer
passage way.
Fluorescent type Lights with globe to be installed for inner passage way.
Working Lights
Waterproof fluorescent lamps and partially incandescent lamps to be installed for
general illumination in engine roon,
Fluorescent lamps or incandescent lamps to be installed in each compartment, elsenbere
entioned above.
‘Two (2) 500W incandescent type flood Lights to be provided for general illumination
of upper main part in engine room.
Deck Lighting
Four (4) 800W incandescent type deck flocd lights to be provided on fore mast and
‘two (2) 500W incandescent type deck flood lights to be provided on aft of mooring
space.
Each one (1) 80W boat deck Lights to be installed near life boats at both sides and
fed from ACLOOV main and/or emergency sources.
Each two (2) 400W mercury type deck flood lights to be provided at forward on each
deck crane.
‘Total two (2) 700W mercury type projectors for Suez canal and other use to be provided
at each side end of navigation bridge wing.
(1) GOW incandescent light to be installed for forward life raft.
ALL the above fixed type deck Lights except deck crane lights to be controlled from
wheelhouse.
E- 239.3.5
9.3.7
Portable lamps
‘Ten (10) 60W portable hand lamps with guard and cabtyre cords 10m length to be supplied
and their receptacles to be fitted at suitable position.
‘Twelve (12) 500W non-flane-proof portable cargo lights with guard and cabtyre conis
of 30m length to be supplied and their receptacles to be fitted in suitable spaces
Snergency Lights
Buergency lights to be provided as follows;
wheelhouse, chart space, radio space, captain's day room, chief engineer's day roo,
ship's office, officer's smoking room, officer's mess room, crew’s mess and Tecreation
Toom, emergency generator room, hospital, steering gear room, emergency fire pump
space, engine control room, engine room, near life boat and life raft spaces, all
Storage positions for firemen’s outfits, escape trunk, main passage and stair ways
(about 1/3 all passage lights), fire control station, life boat light, O0e bottle rooa,
outside passage around accommodation space.
Above energency lights to be fed automatically from energency switch board when the
main source is failed.
‘Two (2) 20W battery lamp (DC24V) to be installed in the MDSS control space.
The lamp to be fed from the radio use battery and controlled from the GMDSS control
space.
Funnel mark Lights
Total two (2) 300W incandescent type flood lights to be provided at each side on
navigation bridge deck.
B- 24a4
NAVIGATION LIGHTS
Aconplete set of electric running lights and signal Lights required by the Rules and Regulations
to be installed as follows:
$.4.1 Running Lights
1 ~ Masthead Light (80)
1 ~ Range Light (60%)
1 ~ Stern Light (40W)
1 = Port side Light (60¥)
1 ~ Starboard side light (60W)
‘The runing Lights to be of duplicate bulb type connected to a running light indicator
nel in wheelhouse, and ACIOOV source to be supplied through duplicate
circuits; namely one to be led directly frommain switchboard, the other from exergency
switchboard.
9.4.2 Signal Lights
2 ~ 40W anchor Lights
(fixed single bulb type, white color)
2 ~ 680W not under command lights
(fixed single bulb type, red color)
1 set - 4%20W Morse-code signal light on radar mast with two (2)
push button switches at both sides in viteelhouse
2 20W steering Lights with dimer switch on fore mast
(fixed type, blue color)
1 ~ 60W portable daylight signaling Light with two (2) receptacles
2 ~ 60W portable waming lights for bewaring of propeller
1 set - 40W Sampan call lights and quarantine Light
(white color 5, red color 4, green color 1)
1 ~ 40W Suez canai stem red signal light
(fixed type)
1 ~ Receptacle with switch for forward Suez canal search Light
{Suez canal search light to be supplied by omer)
Al the above signal Lights to be controlled from wheelhouse except receptacle for
Suez canal search light.SECTION 10 - ELECTRIC INTERIOR COMMUNICATION EQUIPMENTS :
10.1 TELEPHONE BQUIPMENTS
Telephone equipments to be fed from DC24V source and to be installed as follows:
10.1.1 Conon Battery Telephones
Viheelhouse 7 Engine control room(panel mounted type)
(panel mounted type) ————— Steering gear room{wall mounted type)
Connon battery telephone to be fed from DC24V source.
10.1.2 Automatic Exchanged Telephones
One (1) set of automatic exchanged telephone system (with paging) to be installed
as follows:
Automatic exchanger Charging room
(with voice paging access system) ‘
‘Telephones;
1, Wheethouse (panel mounted type)
2. Engine control room (panel mounted type)
3. Radio space (desk type)
4. Captain’ s day room and bed room (desk type comon use)
5. Chief engineer’ s day and bed room (desk type common use)
6. Chief officer’ s room (desk type)
7. Ist engineer’ s room (desk type)
4. 2nd officer’ s room (desk type)
9. 2nd engineer’ s room (desk type)
10. 3rd officer’ s room (desk type)
11. 3nd engineer’ s room (desk type)
12, Officer? s mess room (desk type)
13, Officer’ s smoking room (desk type)
14, Crew’ mess & recreation room (desk type)
15. Ship’ s office (desk type)
18. Chief cook Room (desk type)
17, Boatswain’? s room (desk type)
18. Hospital (desk type)
19. Boy? s room (desk type)
20. Electrician room (desk type)
B- 2621, Galley (wall mount type)
22, Boergency generator room (wall mount type)
23, Pilot room (desk type)
24. 0.8.M. room (A) (desk type)
25, 0.8.M. room (B) (desk type)
26. A. S. M. room (A) (desk type)
27. A. 8. M. room (B) (desk type)
28. A. S. M. room (C) (desk type
29, No.1 oiler’ s room (desk type)
30. Oiler’ s room (A) (desk type)
31. Oiler’ s room (B) (desk type)
32. Oiler’ s room (C) (desk type)
33. Officer’ s spare room (desk type)
34. Crew’ s spare room (desk type)
35. Steering gear room (wall mount type)
Output of automatic telephone (paging) system to be comected as input of public
address system.
Automatic exchanged telephones to be fed from ACLOOV source and automatically fed
from DC24V source when the ACIOOV source is failed.
B2710.2 CALL SIGNAL BELLS
Call signal bell system to be fed from ACLOOV main and/or exergency sources,
and to be installed as follows:
wheelhouse ~<——_______ Hospital
(buzzer) (push button)
Engine control room —————> “A” , “3” and “C” deck inner passage near
(switch) engineer's room
(buzzers)
Each refrigerated > “A” deck passage, galley
provision chamber (buzzer)
10.3 GENERAL ALARMS
General alarm system to be fed from ACLOOV main and/or emergency sources,
and to be installed as follows:
Bells with red lamps;
“C” deck inner passage
“B" deck inner passage
“a” deck inner passage
Upper deck inner passage
Engine control room
Buzzers
Bach cabins a
Air hor,
Engine room 1
Switch
tiheelhouse 1
Fire station
10.4 ENGINEER'S ALARMS
One (1) set of engineer's alarm system consist of pressure, teaperature and level alarms to
be provided on engine control console in engine control room and to be fed from ACIOOV and
De2av sources.
As for detail, refer to Machinery Specifications.
10.5 RUDDER INDICATORS
One (1) set of electric rudder angle indicator systen of self-synchronous type to be fed from
ACLOOV main and/or emergency sources, and to be installed as follows:
1 ~ Transmitter Steering gear room
4 ~ Indicators Vheelhouse, navigation bridge wings,
Engine control room
B- 2810.6
10.7
10.8
HORNS
‘Two (2) sets of air horn with space-heater to be installed on radar mast and fore mast, and
to be controlled by timer.
Air hos to be fed from ACIOOV main and/or energency sources.
FIRE DETECTING SYSTEM
One (1) set of fire alam and detecting system to be fed from ACLOOV and DC24V
Sources, and to be installed as follows:
Fire detecting indicator
Main bell
Bells, buzzers : Common use for general alarm
Sensors : Adequate Nos,
ELECTRIC CLOCKS
One (1) set of crystal controlled electric clock system to be installed as follows:
1 Master clock : Chart space
16 Slave clocks : (1) Wheelhouse,
(2) Bngine control room
(3) Captain’s day room
(4) Chief engineer’s day room
(5) Chie? officer's room
(6) 1st engineer's room
(7) Officer's mess room,
(8) Officer's saoking room
(9) Crew's mess & recreation room
(10) Ship’s office
(11) Pilot room
(12) “C” deck passage
(13) “B” deck passage
(14) “W deck passage
(15) Hospital
(16) Galley
ALL slave clocks to be of two hands ordinary type
Electric clock to be fed from ACIOOV source and automatically fed from DC24V source when the
ACLOOV source is failed.
B- 29SECTION 11 — ELECTRIC NAVIGATION EQUIPMENTS
11.1 GYRO COMPASS AND AUTO PILOT
One (1) set of combined type gyro compass and auto pilot to be installed as follows:
1 ~ Master compass and auto \iheelhouse
pilot steering stand
1 - Alarm unit ‘Whee1house
1 set ~ Accessories Wheelhouse
1 ~ Repeat back unit Steering gear room :
4 ~ Repeater compasses One (1) for front wall in wheelhouse
Bach one (1) for navigation bridge both wings
One (1) for steering gear room
Gyro compass and auto pilot to be fed from ACH4OV and/or ACLOOV sources and DC24V source.
11.2 WIND DIRECTION AND SPEED METER
One (1) set of electric wind direction and speed meter to be fed from AC1OOV main and/or emergency
sources, and to be installed as follows:
1 ~ Transmitter Radar mast,
1 - Indicator Wheelhouse
11.3 ECHO SOUNDER
One (1) set of electric striation type echo depth sounder to be fed from ACIOGV main and/or \
energency sources, and to be installed as follows:
1 ~ Recorder and its accessories Wheelhouse
Frequency 200K
Depth range 0-400m
1 = Transducer Bottom of forward part,
The scale unit to be of SI unit system.
E- 304
16
CLEAR VIEW SCREENS AND WINDOW WIPERS
‘Two (2) sets of clear view screens with space-heater to be installed on suitable front, windows
in wheelhouse, and the diameter of the revolving glass to be of 300m.
Three (3) sets of electric pendulum type window wipers with space-heater to be installed on
suitable front windows in wheelhouse in accordance with Panama Canal Navigation Rules.
Clear view screens and window wipers to be fed from ACIOOV main and/or energency sources.
DOPPLER L¢
One (1) set of doppler speed log to be fed from ACLOOV main and/or emergency sources, and
to be installed as follows
1 - Transducer Bottom of forward part,
1 - Main display Chart space
1 ~ Speed indicator \iheelhouse
NAVTEX RECEIVER
One (1) set of NAVTEX receiver to be fed from DC24V source, and to be installed as follows:
1 Whip antenna Compass deck
1 ~ Main unit Chart space
B-31SECTION 12 - RADIO EQUIPMENTS
12.1 RADIO TELEPHONE
Radio telephone to be fed from ACLOOV and DC24V sources and to be installed as follows:
1 ~ Console type Radio space
1 ~ $8B radio telephone (simplex, 250W pep)
NBOP (with printer)
NE/HE DSC watch receiver
‘DSC terminal (for ME/HF)
~ 20 printer
Battery charger
1 = Main antema Navigation bridge deck
12.2 V.HLP. RADIO TELEPHONES
‘Two (2) sets international V.Hl.F. radio telephones to be fed from ACLOOV and DC24V sources and
to be installed as follows:
1 ~ Transnitter-receiver wheelhouse front. wall
with control panel
built in watch keeping receiver
(with DSC and printer)
1 ~ Transmitter-receiver Wheelhouse group panel
with control panel
(without DSc)
a - Antennas Radar mast, Compass deck
ViF 2
DSC receiver 1
‘The particulars to be as follows:
Channels 57 international channels (digital type)
Operating mode Simplex
Power output 25w/1W
‘These VHF radio telephones cover all channels specified in the ITU radio regulation, U.S.A.
channels, weather channels, and Canadian channels, available along the coast of North Auerica
B- 3212.3
124
12.6
12.7
One (1) satellite B.P.1.R.B (Euergency Position Indicating Radio Beacon) to be provided on
navigation bridge
\-WWAY V.H.P. RADIO TELEPHONES APPARA’ Miz
Three (3) sets two-way radio telephones for GMDSS (VHF 150 Miz), with each battery and battery
quick charger to be provided.
Spare primary batteries also to be supplied according to 1M) requirement.
.F._ ONB IICATION APPARATUS (4 SUPPLY)
‘Two-way radio telephones for on board communication (UHF 400Mz) to be supplied by Omer.
DAR TI NDEI :
Each one (1) set of radar transponders to be installed on navigation bridge deck both wings.
and each one (1) set of socket holder for lifeboat to be installed on each life boat.
SATELLITE COMMUNICATION SYSTEM (INMARSAT-C
INWARSAT ship earth station for satellite commmication system to be fed from DC24V source and
to be provided as follows:
1 ~ Hemisphere antenna Radar mast
1 ~ Date terminal and Radio space
RO printer
1 - ssas
SATELLITE NICATION SYSTEM (INMARSAT-F’
INWARSAT ship earth station for satellite communication system to be fed from ACIOOV main and/or
emergency sources, and to be provided as follows:
1 ~ Radome antenna Radar mast
1 - Main mit Radio space
1 Telephone Radio space
1 ~ Facsimile Radio space
1 - Buzzer boxes “A” deck passage
1 - Remote telephone Captain's day room
Personal computer and internet system to be supplied by Omer.
1 ~ Ship's LAN system
Hub Captain’ s day room,
Nodular Radio space, Captain day room,
Ship’s office
B- 331.4
‘SECTION 13 - ELECTRONIC EQUIPMENTS
RADARS
‘Two (2) sets of relative-motion two unit type marine radars with gyro repeater to be fed from
ACIOOV main and/or ewergency sources, and to be installed as follows:
13.1.1 No.1 Radar combined with ARPA
Display unit
Effective diameter
Max. range
Peak pover
Wave length
Scanner
Performance monitor
13.1.2 No.2 Radar combined with ARPA
Display unit
Effective diameter
Max. range
Peak power
Wave length
Scanner
Performance monitor
‘Wheelhouse
340nm nominal diameter LCD
(raster-scan)
Maker standard
25kW
30m (X band)
Radar mast
Radar mast
Wheelhouse
340am nominal diameter LCD
(raster-scan)
Naker standard
kW
10cm (8 band)
Radar mast
Radar mast
Inter-change-switeh function not to be provided
Recommendation on Performance Standards for Radar Equipments (Annex 4) of Resolution NSC.64(67)
to be complied.
B- 3413.2 DIPPERENTIAL GPS NAVIGATOR
One (1) set differential GPS Navigator to be fed from DC24V exergency sources,
and to be installed as follows:
1 GPS antenna Compass deck
1 = Display unit ‘wheelhouse
1 ~ Buffer unit wheelhouse
(Output signal : VHF x 2, Radar x 2, AIS, VDR, Gyro compass, InnarC)
13.3 WEATHER PACSINILE RECORDER
One (1) set of weather facsimile recorder to be fed from ACIOOV main and/or emergency sources,
and to be installed as follows:
1 = Whip antenna Compass deck
1 - Display unit Whee lhouse
(built-in recorder)
(10-inches recording paper)
13.4 AIS (At ic Identification System:
One (1) set of AIS to be fed from DC24V emergency sources, and to be installed as‘follows:
1 ~ AIS transponder Compass deck
1 - Indicator \Wheelhouse
1 ~ Pilot plug wheelhouse
13.5 VDR (Voyage Data Recorder.
One (1) set of VDR system to be fed from ACIOOV energency source and to be provided as follows;
1 ~ Data capsule unit Compass deck
1 ~ Data collecting unit wheelhouse
13.6 SSAS (Ship Security Alert Systé
One set of SSAS to be provided as follows;
1 ~ Included in INVAR~C
2 - Alert push button Wheelhouse & other space
B- 35141
14.2
SECTION 14 - PUBLIC ADDRESSSYSTEM AND MISCELLANEOUS RADIO EQUIPMENTS
‘UBLIC_ADDRE: TEN
One (1) set of public address system to be fed from ACIOQV main and/or emergency sources, and
to be installed as follows:
Loud speakers;
1 100W amplifier cabinet Wheelhouse
Each 1 10W water-proof loud speaker (portable type) F* cle deck and upper deck aft
1 10W water-proof loud speaker Bngine room
Bach 1 SW water-proof loud speaker Navigation bridge both wings
1 SW water-proof loud speaker with volume Galley
1 BW water-proof Conon lavatory
Each one (1) set of 2W cabin type loud speaker to be provided in following spaces;
Toner passages in accommodation spaces (wall mount type total 6), engine control room (flush ‘i
type), officer” smess room, Officer’ s snoking room (flush type), crew’ s mess & recreation
room (flush type), each cabin (flush type) and ship’ s office (flush type).
Each one (1) set of hand type microphone to be provided in following spaces:
Nain cabinet in wheelhouse, navigation bridge wings, windlass space on f° cle deck and
mooring winch space on upper deck.
This system to be included one (1) set of talk-back system as follows;
‘Nheelhouse F cle deck
Upper deck aft and steering ,
gear room
‘TELEVISION/BROADCASTING RADIO ANTENNA AND TELEVISIONS
Each one (1) set of color (about 21 inch) type television receiver with world wide tuner to
be provided total in officer’ s smoking room and crew’ s mess & recreation room.
One (1) set of done type television antenna for UF and VHF and broadcasting radio antenna to
be installed on compass deck.
‘Antenne outlet to be installed in all cabins.
B- 3615.1
SECTION 15 - SPARE PARTS AND OUTFITS
SPARE PARTS
Spare parts to be fumished in accordance with the requirements of the Classification Society
and Builder's standard,
Following electric spare parts in steel or adequate boxes to be fumished.
16.1.1 For Bach Kind of A.C. Generators
Protective resistors for each 2 or less
Rectifier elements for each 2 or less
Air filters for each 1
Thermoneters for each 2 or less
Set of each size bearings or bearing linings
Heating body of space heaters for each 4 or less
1.1.2 For Each Kind Exciting Dev:
1 ~ set of rectifier
1 ~ set of resistors and capacitors for each size.
15.1.3 Por of Motors
1 ~ Ball bearings for each 4 or Less
Donestic service motors and special motors integrated in auxi:
manufacturers’ standard.
ary machines
1.14 For Total Set of Motor Controls
Contact, segnents for each 4 or less
Springs for each 10 or less except over load relay
Operating coils and shunt coils for each 10 or less
Resistors of each kind and size for each 20 or less
Bulb of lamps for each 1
Pilot lamps for each kind for each 10 or less
~ Fuse cases for each size for each 10 or less, up to Max.10
Fuse elenents for each 1, up to Max.10
Complete set of over load relays for each kind
Domestic service motors and special motors integrated in auxiliary, machines
manufacturers’ standard.
B-376.15 For ey Switchboard
~ ACB aux. contacts for each 1
~ ACB aux. switch contacts for each 1
~ Springs for ACB for each 1
~ Complete circuit breakers for each 10 or less
Voltage coils for each 1
Balb of pilot lamps for each 1
Pilot lamp globes for each 10 or less
~ Resistors of each kind and size for each 1
~ Ruse cases for each 10 or less, up to Max.10
~ Ruse elements for each 1
15.1.6 For Distribution Panels
1 ~ Complete circuit breakers for each 10 or less, up to Max.10
1 ~ Fuse cases for each 10 or less, up to Max.10
1 ~ Fuse elements for each 1
15.1.7 For Electric Lighting Fixtures
1 ~ Bulbs for each 10
1 - Fluorescent tubes for each 10
1 ~ Glow lamps for fluorescent tube for each 10
Each kind 1 - Flood light bulbs
3. ~ Water-proof switches
3. ~ Non-waterproof switches
3 pair - Waterproof plugs/receptacles with switches .
3 pair - Non-waterproof plugs/receptacles
2 ~ Water-proof receptacles
1 ~ Socket for bi-pin type fluorescent tubes for each 20
15.1.8 For Communications, Public Address System and Miscellaneous Radio Equipments
To be according to manufacturers’ standards.
15.1.9 For Navigation Instruments
To be according to manufacturers’ standards.
151.10 For Radio Bauil
To be according to the Tele-comunication Radio Regulations and
manufacturer’ s standard.
18.111 Electronic Equipments
To be according to manufacturers’ standards.
E- 3815.2 OUTFITS
Following outfits to be furnished.
15.2.1 Outfits
~ Megger, in Ma scale with 500V
- Circuit tester
~ Cramp meter (0-15/60/300A, 0~150/300/600/V)
- Knives
~ Screw drivers set (insulated)
~ Cutting pliers
~ Nipper
~ Neon test lamps for low volt(80—300V)
Pair of rubber glove
~ Flash Light
~ Plier
~ Electric soldering iron (60W)
- Resin-cord solder
= Tool box
- Insulation vinyl tapes (Red)
~ Insulation vinyl tapes (White)
~ Insulation vinyl tapes (Blue)
20 - Spring connectors (Red)
20 - Spring connectors (Yellow)
30m - Cable (TPYC-1.5)
30m - Cabtyre cable (2PNCT-1.25~3C)
15.2.2 Maintenance tools and materials for storage batteries
~ Syringes
~ Funnel
~ dug (2)
~ Rod type thermometers (~20°C to +100°C)
Portable volt meter (-3V ~ +3V)
~ Hydrometers
~ Acid bottle (5 )
~ Distillated water bottle (18 )
~ Tool box
E- 39/8