WHAT IS BOD?
BIOCHEMICAL OXYGEN DEMAND ALSO KNOW AS BIOLOGICAL OXYGEN
DEMAND.
IT IS DEFINED AS THE AMOUNT OF OXYGEN CONSUMED BY MICROORGANISM
TO BREAKDOWN THE ORGANIC CONTENT OF A WASTE WATER(SAMPLE)
MEASURED IN MG/LITRE.
IT IS A 5DAYS TEST.
ALSO REFERRED TO AS BOD5.
BOD FOLLOWS 1ST ORDER KINETICS (C=C0 EXP(-KT) )
ULTIMATE BOD=C0(1-
EXP(-KT))
SIGNIFICANCE OF BOD: BOD IS THE TRADITIONAL, MOST WIDELY USED TEST TO ESTABLISH
CONCENTRATION OF ORGANIC MATTER IN WASTEWATER SAMPLES (I.E.,
RELATIVE STRENGTH).
BOD IS BASED ON THE PRINCIPLE THAT IF SUFFICIENT OXYGEN IS AVAILABLE,
AEROBIC BIOLOGICAL DECOMPOSITION (I.E., STABILIZATION OF ORGANIC
WASTE) BY MICROORGANISMS WILL CONTINUE UNTIL ALL WASTE IS
CONSUMED.
WASTE TYPE
Vegetable Washings
2000
Dirty Water
1500
3500
15000
Cattle Slurry
15000
Pig Slurry
25000
40000
Silage Effluent
55000
Milk
140000
PERMISSIBLE LIMIT OF BOD: PERMISSIBLE LIMITS FOR VARIOUS PARAMETERS FOR DRINKING WATER CAN BE FOUND
IN INDIAN STANDARDS FOR DRINKING WATER SPECIFICATION (IS 10500:1991). BOD AND
COD FOR DRINKING WATER SHOULD BE NIL.
WASTEWATER DISCHARGE LIMITS ARE GIVEN BY CPCB EFFLUENT DISCHARGE
STANDARDS, WHICH MENTION PERMISSIBLE LIMITS FOR DISPOSAL INTO INLAND
SURFACE WATER, ON LAND FOR AGRICULTURE, INTO PUBLIC SEWERS AND FOR MARINE
DISPOSAL.
BOD < 30 MG/L AND COD<250 MG/L FOR INLAND SURFACE WATER DISPOSAL AS PER
CPCB STANDARDS
BOD EQUIPMENTS:-
BIOSENSORS.
SOFTWARE SENSOR.
ELECTROCHEMICAL SENSORS.
DISADVABTAGES OF BIO SESNORS: IT REQUIRES ACTIVATION EACH AND EVERY TIME BEFORE USING.
MAINTENANCE COST IS VERY HIGH.
IT RUNS FOR A LIMITED TIME BECAUSE REACTIVATION IS REQUIRED.
IT DOESNT RESPOND WELL TO QUALITY CHANGING CHARACTERISTIC OF THE
WASTE WATER. (DIFFUSION PROCESS OF VARIOUS MICRO ORGANISMS).
ELECTROCHEMICAL SESNORS
FOR TESTING BOD
MADE UP OF GOLD CATHODE, SILVER ANODE, ELECTROLYTIC SOLTUON AND PE
MEMBRANE TO CREATE A POTENTIAL ACROSS THE MEMBRANE.
O2 IS CONSUMED BY AU CATHODE AFTER VOLTAGE IS APPLIED TO THE AG ANODE.
IT MEASURE THE DIFFUSION RATE OF OXYGEN.
IT DOESNT MEASURE THE CONCENTRATION OF OXYGEN BUT PARTIAL PRESSURE
OF O2 IN %SATURATION.
DATA CALIBATED IN SOFTWARE AND THE BOD VALUE IS OBDTAINED BY USING O2
SOLUBITITY CHART DATABASE.
ELECTROCHEMICAL SENSOR
WORKING MODEL: IN ELECTROCHEMICAL SENSORS, O2 MOLECULES DIFFUSE THROUGH THE
MEMBRANE TO THE SENSOR AT A RATE PROPORTIONAL TO THE PRESSURE
DIFFERENCE ACROSS IT.