System
Loading Software
Siemens AG
2006
English
Doc. Gen. Date: 09.06
n.a.
Revision / Disclaimer
1Revision / Disclaimer
Copyright
Copyright 2006 by Siemens Corporation. All rights reserved. No part of this publication
may be reproduced, transmitted, transcribed, stored in retrieval systems, or translated into
any language or computer language, in any form or by any means, electronic, mechanical,
magnetic, optical, chemical, manual, or otherwise, without the prior written permission of
Siemens Corporation. Siemens Corporation reserves the right to change its products and
services at any time. In addition, this manual is subject to change without notice. Siemens
Corporation welcomes customer input on corrections and suggestions for improvements
to this manual.Although Siemens Corporation has attempted to ensure accuracy throughout this manual, Siemens Corporation assumes no liability for any errors or omissions, nor
for any damages resulting from the application or use of this information.
Trademarks
ACUSON, Sequoia, Cypress, AEGIS, Aspen, 128XP, XP, AcuNav, CV70, SONOLINE,
SONOVISTA, Adara, Antares, G20, G40, G50, G60S, X300, X500, Omnia, Premier and
KinetDx are trademarks of Siemens Corporation registered in the U.S. Patent and Trademark Office. CWS3000, DS3000, WS3000, and WebPro are trademarks of Siemens Corporation.
Windows XP, 2000 and NT are registered trademarks of Microsoft Corporation. Internet
Explorer is a trademark of Microsoft Corporation. Netscape and Netscape Navigator are
registered trademarks of Netscape Communications Corporation. Java and the JavaScript
name are registered trademarks of Sun Microsystems, Inc. Adobe Acrobat is a registered
trademark of Adobe Systems, Inc.
Other products and brand names are trademarks of their respective owners.
Disclaimer
The service of equipment described herein is to be performed by qualified personnel who
are employed by Siemens or one of its affiliates or who are otherwise authorized by Siemens or one of its affiliates to provide such services.
Assemblers and other persons who are not employed by or otherwise directly affiliated
with or authorized by Siemens or one of its affiliates are directed to contact one of the
local offices of Siemens or one of its affiliates before attempting installation or service procedures.
License Agreement
All computer programs copyright 1990-2006 by Siemens Corporation or its suppliers. Programs are licensed under the following agreement:
Siemens or its suppliers retain(s) ownership of and title to any computer program supplied
with the equipment and to the trade secrets embodied in such computer programs. Subject to the Buyers acceptance and fulfillment of the obligations in this paragraph, Siemens
grants the Buyer a personal, non-transferable, perpetual, non-exclusive license to use any
computer program supplied with the Equipment that is necessary to operate the Equipment solely on the medium in which such program is delivered for the purpose of operating the equipment in accordance with the instructions set forth in the operators manuals
supplied with the Equipment and for no other purpose whatsoever. Buyer may not
reverse-assemble, reverse-compile or otherwise reverse-engineer such computer programs nor may Buyer make a copy of such program or apply any techniques to derive the
ACUSON X300
US11-101.816.01.01.02
09.06
Page 2 of 32
sd
Siemens
Medical Solutions USA, Inc.
Revision / Disclaimer
trade secrets embodied therein. In the event of a failure by Buyer to comply with the terms
of this license, the license granted by this paragraph shall terminate. Further, because
unauthorized use of such computer programs will leave Siemens without an adequate
remedy at law, Buyer agrees that injunctive or other equitable relief will be appropriate to
restrain such use, threatened or actual. Buyer further agrees that (i) any of Siemens"s
suppliers of software is a direct and intended beneficiary of this end-user sublicense and
may enforce it directly against Buyer with respect to software supplied by such supplier,
and (ii) No supplier of Siemens shall be liable to buyer for any general, special, direct, indirect, consequential, incidental or other damages arising out of the sublicense of the computer programs supplied with the equipment.
Siemens
Medical Solutions USA, Inc.
US11-101.816.01.01.02
09.06
Page 3 of 32
sd
ACUSON X300
Table of Contents
1-
0Table of Contents
6
6
6
6
10
10
10
10
23
23
23
24
25
Sleep Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
System Configuration: Hardware Version 2.0 - Software Version 2.0. . . . . . . . . . . . 27
System Configuration: Hardware Version 1.0 - Software Version 2.0. . . . . . . . . . . . 28
ACUSON X300
US11-101.816.01.01.02
09.06
Page 4 of 32
sd
Siemens
Medical Solutions USA, Inc.
2-
Overview
1Loading System Software
The instructions below describe how to load system software on the system.
Observe the following Caution alerts before proceeding.
CAUTION
If the system software will be upgraded (or downgraded to an earlier version) for testing or to resolve an operational problem, the
feature keys for options that are not supported by the installed version will be lost.
To avoid this problem, uninstall all feature keys before upgrading
or downgrading the system software. See (US07-102.892.01 / Uninstalling the Product Feature Keys) for details.
Be sure that all feature keys are properly re-installed
after upgrading (or downgrading) software.
File System
Contents
C:
NTFS
Windows XP
Software (in-
Remains
cluding DIMAQ,
syngo, SCR
3D)
D:
Siemens
Medical Solutions USA, Inc.
60 GB
US11-101.816.01.01.02
09.06
NTFS
Page 5 of 32
sd
Patient data
and image files
(including Quick
Set and Imaging Preset).
ACUSON X300
Setup Requirements
Reference Documents
None
Time Required
Approximately 30 minutes is required to load software. More time will be required if the
customers data is backed up.
ACUSON X300
US11-101.816.01.01.02
09.06
Page 6 of 32
sd
Siemens
Medical Solutions USA, Inc.
3-
Use the following instructions to verify the system software version of ACUSON X300
ultrasound system.
1. Power on the system and wait for the system to boot up.
2. Press Presets. The Preset Main Menu displays.
Fig. 1:
Siemens
Medical Solutions USA, Inc.
US11-101.816.01.01.02
09.06
Page 7 of 32
sd
ACUSON X300
Fig. 2:
NOTE
ACUSON X300
US11-101.816.01.01.02
09.06
Page 8 of 32
sd
Siemens
Medical Solutions USA, Inc.
4-
Overview
3Loading System Software
The instructions below describe how to load system software on the ACUSON X300.
Observe the following Caution alerts before proceeding.
CAUTION
If the system software will be upgraded (or downgraded to an earlier version) for testing or to resolve an operational problem, the
feature keys for options that are not supported by the installed version will be lost.
To avoid this problem, uninstall all feature keys before upgrading
or downgrading the system software. See (US11-102.816.01 / License Key Installation) for details.
Be sure that all feature keys are properly re-installed
after upgrading (or downgrading) software.
Siemens
Medical Solutions USA, Inc.
US11-101.816.01.01.02
09.06
Page 9 of 32
sd
ACUSON X300
10
Setup Requirements
Reference Documents
None
Time Required
Approximately 30 minutes is required to load software. More time will be required if the
customers data is backed up.
ACUSON X300
US11-101.816.01.01.02
09.06
Page 10 of 32
sd
Siemens
Medical Solutions USA, Inc.
11
Use (Verify System Software / p. 7)to verify the software version before proceeding.
Siemens
Medical Solutions USA, Inc.
US11-101.816.01.01.02
09.06
Page 11 of 32
sd
ACUSON X300
12
Backing Up Data
ACUSON X300
US11-101.816.01.01.02
09.06
Page 12 of 32
sd
Siemens
Medical Solutions USA, Inc.
13
Fig. 3:
Siemens
Medical Solutions USA, Inc.
US11-101.816.01.01.02
09.06
Page 13 of 32
sd
ACUSON X300
14
Fig. 4:
ACUSON X300
US11-101.816.01.01.02
09.06
Page 14 of 32
sd
Siemens
Medical Solutions USA, Inc.
15
Fig. 5:
Siemens
Medical Solutions USA, Inc.
US11-101.816.01.01.02
09.06
Page 15 of 32
sd
ACUSON X300
16
Fig. 6:
ACUSON X300
Authentication Screen
US11-101.816.01.01.02
09.06
Page 16 of 32
sd
Siemens
Medical Solutions USA, Inc.
17
Fig. 7:
Siemens
Medical Solutions USA, Inc.
US11-101.816.01.01.02
09.06
Page 17 of 32
sd
ACUSON X300
18
Fig. 8:
Fig. 9:
Installation Message
ACUSON X300
US11-101.816.01.01.02
09.06
Page 18 of 32
sd
Siemens
Medical Solutions USA, Inc.
19
11. After the automatic reboot, the system prompts for the type of upgrade to perform.
Siemens
Medical Solutions USA, Inc.
US11-101.816.01.01.02
09.06
Page 19 of 32
sd
ACUSON X300
20
12. Choose the desired upgrade. If a choice is not made in 30 seconds, the system will default to Upgrade/Update Installation.
13. After approximately 7-8 minutes, the system will display a pop-up window asking for the
second CD. The CD tray will open. Remove the first CD and insert the second.
14. After approximately five more minutes, the upgrade is complete, the system will reboot.
After the system completes the reboot, verify the system software version as described
in (Verify the System Software Version / p. 7).
15. Press Preset, then select Service --> Configuration --> License & Components to
confirm newly installed software version.
ACUSON X300
US11-101.816.01.01.02
09.06
Page 20 of 32
sd
Siemens
Medical Solutions USA, Inc.
21
1. Press Preset and select Basic System 1 from the left side of the Preset Main screen.
2. Select the Language Format from the Format pane according to customer need.
Be sure that all feature keys are properly re-installed after upgrading (or downgrading)
software.
3. Select Save.
Siemens
Medical Solutions USA, Inc.
US11-101.816.01.01.02
09.06
Page 21 of 32
sd
ACUSON X300
22
5. Select the Video format from the Peripheral pane according to customer need.
6. Select Save.
7. Restart the system.
ACUSON X300
US11-101.816.01.01.02
09.06
Page 22 of 32
sd
Siemens
Medical Solutions USA, Inc.
23
Use the following instructions to verify that the software is operational and to restore data.
During this last phase of the software installation, the system checks the revision level of
the firmware and BIOS, updating them if necessary.
Before continuing, verify the system is now running the new software.
1. Power on the system and wait for the system to boot up.
2. Press the Preset key to display the Preset Main Menu.
Siemens
Medical Solutions USA, Inc.
US11-101.816.01.01.02
09.06
Page 23 of 32
sd
ACUSON X300
24
ACUSON X300
US11-101.816.01.01.02
09.06
Page 24 of 32
sd
Siemens
Medical Solutions USA, Inc.
25
5. At the product information screen, verify that the correct product Serial No. is displayed: the number displayed on the product Information screen should be identical to
the product Serial Number recorded on the label attached to the rear of the product.
Siemens
Medical Solutions USA, Inc.
US11-101.816.01.01.02
09.06
Page 25 of 32
sd
ACUSON X300
26
2. Insert the Backup CD in the CD-R/W drive and wait approximately ten seconds for the
CD to spin up.
3. Select Restore on the pop-up window to start. The system will display Restore is
completed message.
4. Select Ok and remove the backup CD.
- The system will display Shutdown before the system starts restoring
message.
5. Select Ok to confirm.
6. Close Backup &Restore and select Exit twice to return to the preset menu.
7. Shutdown the system manually and wait for it to shut down
8. Restart the system.
ACUSON X300
US11-101.816.01.01.02
09.06
Page 26 of 32
sd
Siemens
Medical Solutions USA, Inc.
27
Sleep Mode
The Sleep Mode option is a part of software version 2.0. It can be installed on systems
configured with hardware versions 1.0 or 2.0. The Sleep Mode setup is different for each
system hardware version. Use the set of instruction that apply to the system software and
hardware configuration.
1. Press the Preset key. The system displays the Preset Main Menu.
2. Select Service from the Presets menu. The system displays the Service Authentication screen.
3. Enter the password and select Go. The system displays the Service Main Menu.
4. Select Configuration. The system displays the Configuration screen.
5. Select System from the Configuration menu.
6. Select Preset Sleep Mode Option. See (Fig. 18 / p. 27) for location of the option.
Fig. 18: System Information Screen > Preset Sleep Mode Option
Siemens
Medical Solutions USA, Inc.
US11-101.816.01.01.02
09.06
Page 27 of 32
sd
ACUSON X300
28
Fig. 19: Preset Menu > Basic System 1 > Enable Sleep Mode
1. Press the Preset key. The system displays the Preset Main Menu.
ACUSON X300
US11-101.816.01.01.02
09.06
Page 28 of 32
sd
Siemens
Medical Solutions USA, Inc.
29
2. Select Service from the Preset Menu. The system displays the Service Authentication
screen.
3. Enter the password and select Go. The system displays the Service Main Menu.
4. Select Configuration. The system displays the Configuration screen.
5. Select System from the Configuration menu.
6. Deselect the Preset Sleep Mode Option.
Fig. 20: System Information Screen > Preset Sleep Mode Option
The system hide the Enable Sleep Mode option unavailable on Preset Main Menu,
Basic System 1 screen.
7. Select the Save button. The system saves the changes.
8. Select the Close button. The system displays to the Preset Main Menu.
Siemens
Medical Solutions USA, Inc.
US11-101.816.01.01.02
09.06
Page 29 of 32
sd
ACUSON X300
30
Fig. 21: Preset Menu > Basic System 1 > Disable Sleep Mode
ACUSON X300
US11-101.816.01.01.02
09.06
Page 30 of 32
sd
Siemens
Medical Solutions USA, Inc.
31
5-
Change(s)
Description
New document
Initial document.
Siemens
Medical Solutions USA, Inc.
US11-101.816.01.01.02
09.06
Page 31 of 32
sd
ACUSON X300
32
ACUSON X300
US11-101.816.01.01.02
09.06
Page 32 of 32
sd
Siemens
Medical Solutions USA, Inc.