50 kW SOLAR PV BASED GRID TIE

POWER PLANT

SURVEY REPORT
Al-Falah University

Ref: SEI/SPV/50/01/180516

Date: 02 Jan 2016

Dear Sir,

Sub: Survey report for 50KWp Roof Top Solar Power Plant

We enclose the following documents for your kind consideration and reference.

1. Executive summary
2. Benefits of the projects
3. Details of the Projects
4. Expected Annual Energy Generation
5. Technical specification and bill of materials
6. Block diagram of the power plant
7. Scope of work
a. Design work
b. Installation work
8. Clint Scope

PH: +91 75033 25402

Email: soralitepower@gmail.com

1. Executive Summary
Al-Falah University is an endeavour of Al-Falah Charitable Trust, in keeping up with its
tradition of fostering professional education, training and guidance. Spread over 56 acres of
lush greenery, Al-Falah University offers world-class education to students from India and other
countries by providing a learning experience designed to develop intellectual abilities as well as
good social, moral and ethical values. The university is committed to providing a rigorous
academic environment to equip students with knowledge, skills, insights, attitudes and practical
experience in order to enable them to become discerning citizens.
The emphasis by the university is placed on nurturing talent by providing need-based
education to create a resource pool for developing cutting edge technologies for the benefit of
the country. We believe that this pool of immense talent would enrich the national fabric and
shall act as a driving force for transforming India into a great nation. Our curricula and teaching
methods are rigorous, innovative and distinctly oriented towards competitiveness, keeping an
eye on global environment of business, industry and academia. A distinct feature of our
academic programme is the focus on the industrial needs of the country.
India is endowed with vast solar energy potential. About 5,000 trillion kWh per year
energy is incident over Indias land area with most parts receiving 4-7 kWh per sq. m per day.
Hence both technology routes for conversion of solar radiation into heat and electricity, namely,
solar thermal and solar photovoltaics, can effectively be harnessed providing huge scalability
for solar in India.

PH: +91 75033 25402

Email: soralitepower@gmail.com

2. Benefits of the projects

The Project will provide green solar power to the university and will share the load
requirements in synchronization with the Grid.
Directly, the project is expected to generate around 67,110 Units and reduce the Electricity
Charges incurred by the Beneficiary Organization and also the diesel consumption.
We can avoid the 40.06 tons1 of the CO2 by using of this power plant in a year.

3. Details of the Project


Project site: Al-Falah University Admin Building and Mechanical building
Proposed capacity of the SPV Power Plant (KWp): 50KWp
Availability of shadow free south facing area for the power plant: More than 1100
Sq. m shade free area on rooftops of the building is available.

Calculation based on the 0.597kg/kwh.

PH: +91 75033 25402

Email: soralitepower@gmail.com

4. Expected Annual Energy Generation

Months

Units Generated

January

5250

February

5400

March

5550

April

6000

May

6000

June

6000

July

5940

August

5925

September

5745

October

5400

November

5100

December

4800

Yearly

67,110

Note: Energy production projections are reasonably accurate estimates based on sites solar
data and our experience with similar systems. No guarantees as to actual production output
from this system.
Grid/Load Interfacing
Solar system output shall be connected to a suitable load bus capable of taking the input. This
input point shall be selected in field in consultation with clients Executive Engineer.

PH: +91 75033 25402

Email: soralitepower@gmail.com

5. Technical Specification and Bill of material

Description
a
Solar Panels

System Components
Details
b
Quantity: 200
Wattage: 250Wp / 260Wp
No. of Cells: 60
Voc: 37.1 V
Isc: 8.28 A
Vmp: 29.6 V
Imp: 7.6 A
Dimensions: 1660X990X42 (mm)
Weight: 20 kg
Operating Conditions: -40 to +90 C
Maximum System Voltage: 1000 Vdc

Inverter
Quantity: 1 or 2
AC maximum output: 50 KWp
MPP voltage range : 360 800 V
Maximum current input DC/String : 15A
Maximum efficiency : >98.1%
Power connection : 3-phase

Remark
c

As per Clint
requirement

We may take any other reputed make


with efficiency > 95%.
Mounting Structures

PH: +91 75033 25402

Panels shall be mounted on galvanized


frames inclined at 28 degrees to the
south. The structure is designed in
such a manner that module can be
replaced easily and in line with site
requirements and it is easy to install
and service in future. The frames will
be supported by angle legs of suitable
lengths to provide the pre-determined
inclination. All fasteners, nut and bolts
are made of Stainless steel - SS 304.
The structures shall be pre engineered
to meet special requirements of placing
the modules on the corrugated
rooftops.

Accurate degree of
inclined of the solar
module will be
design after survey
of site and collected
the cordinated of the
site.

Email: soralitepower@gmail.com

Foundation Base

The legs of the structures made with GI


square pipe with base plate with
suitable hole and foundation bolts
grouted in the RCC foundation columns
made with 1:2:4 cement concrete.

Electrical Accessories

Cables will conform to IS 694 and shall


be of 1.1 kV grade. Interconnections,
DCDB to PCU etc will be selected to
keep voltage drop and losses to the
minimum. The bright annealed 99.97%
pure bare copper conductors offer low
conductor resistance,
4/6sqmm, TUV certified cable used for
the connection of array to junction
boxes, junction boxes to DCDB
Working voltage: up to 1100 V
Temperature range: -15 deg C to +70
deg C
Sizes: Suitable sizes
Color codes: Red, Yellow, Black, Blue,
Green

Battery

None

Energy Meter

The Inverter shall have a built-in meter


that tracks energy production and
displays it on a small LED screen. The
display can be used to determine realtime production, daily production. For
more sophisticated analysis and visual
data management, Solar Access
modules can be included.

Array Junction Box

Number of string after Design


IP 65 Protection
SPD 1000V DC
10 Amp Fuse per string
DC disconnected switch
TUV Certified

Remote Monitoring
System

The
remote
monitoring
system Optional
continuously records and stores all
available data of number of inverters in
real time.

PH: +91 75033 25402

Email: soralitepower@gmail.com

Solar Power Plant BOM


Sr.
No.

DESCRIPTION OF ITEM

Unit

Solar Module - polycrystalline


(250Wp)

Nos

2.0

Grid connected Inverter 50KWp

Nos.

2.1

Remote monitoring system

Nos.

2.2

Weather sensor

Nos.

2.3

Irradiation sensor

Nos.

AJB

Nos

3
4
5
6
7

4 sq.mm/6sq.mm x 1C PVC Cu.


Conductor Cable for PV Module to
AJB
Structure - (Module Mounting
Arrangement)
4C x 35 sq. mm. XLPE Insulation Al
Conductor GI Armoured Cable
(From Inverter to ACDB )
Earthing with G.I. 40mm dia pipe
including accessories

QTY.

Remark

200.00
1.00
1.00
1.00
1.00

Optional
Optional

2.00

mtr.
As per design
Set

As per design

Mtr
As per design
set

Connectors

Nos.

ACDB

Nos.

10

Fittings ( PVC Pipe, flexible pipe,


cable tie, lugs, anchor fastener etc)

Lot

11

Earthing G.I. strip of 40mm x 5 mm

Mtr.

12

Cable tray

Mtr.

13

Lightning arrester

set

7.00
As per design
1.00
As per design
As per structure
design
10.00
1.00

Note:
a. Sensors are the optional we can avoid to be use these devise.
b. Lightning arrester can also be avoided in case of already having lightning arrester on the
building and cover the entire area of roof where we plan to install the solar modules.

PH: +91 75033 25402

Email: soralitepower@gmail.com

6. Block diagram of the solar power plant

Fig 1: Block Diagram of the solar pv power plant

PH: +91 75033 25402

Email: soralitepower@gmail.com

7. Scope of wok
1. Design Work

a. Civil design: - structure foundation design, Layout plan of site etc.

Fig 2: Reference drawing of the layout of the panels.

PH: +91 75033 25402

10

Email: soralitepower@gmail.com

b. Solar Module mounting Structure design: -

i. Structure design at a certain angle as per latitude of the site.


ii. Structure design to withstand of horizontal wind speed of 150Kms/h.
iii. Structure shading calculation in PVSyst Software.

Fig 3: Reference drawing of the solar module structure.

PH: +91 75033 25402

11

Email: soralitepower@gmail.com

c. Electrical Design: i.
ii.
iii.
iv.

Single line diagram of the plant.


Solar module string design
Power Plant simulation in PVsyst Software.
Sun path and irradiation calculation of the site coordinates for
estimated generation of the power plants.
v. AC and DC wiring design and connection diagram.

Fig 4: PVsyst Software Report for the Power Plant.

PH: +91 75033 25402

12

Email: soralitepower@gmail.com

Fig 5: PVsyst Software report for Sun Horizon definition

Fig 6: PVsyst Software report for Shading calculation

PH: +91 75033 25402

13

Email: soralitepower@gmail.com

Fig 7: PVsyst Software Main result of the Power Plant generation

Note: Fig 4, 5, 6 &7 are the PVsyst Software Reports only for your
references.

PH: +91 75033 25402

14

Email: soralitepower@gmail.com

2. Installation Work

a. Area required: The total area required for the system installation shall be
apx 500 600 Sq meter, without any shades, true south facing.
b. Structure Anchoring: Panels shall be mounted on galvanized frames
inclined at 28 degrees to the south. The structure is designed in such a
manner that module can be replaced easily and in line with site requirements
and it is easy to install and service in future. The frames will be supported by
angle legs of suitable lengths to provide the pre-determined inclination. All
fasteners, nut and bolts are made of Stainless steel - SS 304.
c. Foundation Base: The legs of the structures made with GI square pipe and
nut bolted on the foundation bolts in the RCC foundation columns made with
1:2:4 cement concrete. Actual frame and other structural dimensions will be
determined during a more detailed site visit by specialists during full design
phase.
d. Inverter installation: Based on the initial site visit, the inverters could
possibly be installed on the terrace. This space provides ample accessibility
and good air circulation. The inverter is available in IP54 housing; however,
an enclosed space has to be provided for the same. Actual installation
location and methods will be determined during full design phase.
e. Electrical: Proposed fire hose shaft will be used for running electrical cables
down to the electrical panel room. A detailed electrical design with single-line
diagram and specifications will be prepared during full design phase after
receiving the PO, for the clients approval.

PH: +91 75033 25402

15

Email: soralitepower@gmail.com

8. Clint Scope :-

1. Purchase the material i.e. solar modules, inverter etc.


2. Arrange the material on site before installation.
3. Storage for the material.
4. One light point and one water points for the installation team.
5. All kind of pass for the installation team and equipments.
6. Civil foundation of the structure.
7. Structure part assembling on roof.
8. Net metering connection in scope of the Al-Falah University.
9. All the Statutory clearances, if any, required for the Project taken by Clint.

*************************************************************************************************************
*************************************************************************************************************
*