You are on page 1of 9

DEPARTMENT OF TRANSPORTATION

INSPECTION REPORT

FEDERAL RAILROAD ADMINISTRATION (FRA)


Inspector's Name

Inspector's Signature

OMB Approval No.: 2130-0509

Inspector's ID No.

HOLM, STEVEN L.

00417

Railroad/Company Name & Address

R/C

UNION PACIFIC RR CO.

1000 E 1ST ST.


THE DALLES

OR

97355

Date

Report No.

28

yy

mm

2016

04

Division

RR/Co. Representative (Receipt Acknowledged)

SYSTEM

Name

PETE VALLEJO

RR/Co.
Code

Subdivision

Title

TRACK INSPECTOR

UP

PORTLAND

Email

dd

27

Signature
From:
City

THE DALLES

State
County

Codes

2060

Destination City & County

OR

41

City

WASCO

C065

County

Mile Post: From

0084.68

To

CASCADE LOCKS

HOOD RIVER
Inspection Point CORTEX TRACK INSPECTION

0035.30

Activity
Code:

MTH

MTW

RMM

RWP

TOM

Units:

48

14

Sub Units:

Item

Initials/Milepost

0084.59

Equipment/Track #

MAIN 1

Type/Kind 49 CFR/
USC

213

From Latitude

Codes

Defect

Subrule

Speed

0133

A12

40

0300

From Longitude

C027

To Latitude
To Longitude

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE FROG BOLTS. ( CHERRY GROWERS, 1 MIDDLE FROG, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

Initials/Milepost

0084.59

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

MAIN 1

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0135

A1

Date(mm/dd/yyyy):
Speed

40

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
STOCK RAIL NOT SECURELY SEATED IN SWITCH PLATES. ( LEFT HAND SIDE AT HEEL OF SWITCH, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Yes

No

Required

Optional

Written Notification to

FRA of Remedial Action is:

Hazard Class

Latitude:
Railroad Action Code

Source Code File Number

UN/NA ID

Longitude:
Date(mm/dd/yyyy):

Comments on back?

ID's of Accompanying
Inspector(s)

R8CORTEX

Page
FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs

FRA COPY

of

**RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences

DEPARTMENT OF TRANSPORTATION

INSPECTION REPORT

FEDERAL RAILROAD ADMINISTRATION (FRA)


Inspector's ID No.

Report No.

00417
Item

28

Initials/Milepost

0083.82

OMB Approval No.:

(Continuation)

2130-0509

Report Date

4/27/2016

Equipment/Track #

MAIN 1

Type/Kind 49 CFR/
USC

213

Defect

Subrule

0133

A9

Speed

40

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE ADJUSTABLE RAIL BRACES. ( CHERRY GROWERS 2, RIGHT HAND SIDE GAGE PLATE, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

Initials/Milepost

0083.82

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

MAIN 1

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0135

A1

Date(mm/dd/yyyy):
Speed

40

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
STOCK RAIL NOT SECURELY SEATED IN SWITCH PLATES. ( RIGHT HAND SIDE AT HEEL, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

Initials/Milepost

0083.82

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

MAIN 1

Type/Kind 49 CFR/
USC

UN/NA ID

213

Date(mm/dd/yyyy):

Defect

Subrule

Speed

0133

A12

40

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE FROG BOLTS. ( 1 IN HEEL, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

Initials/Milepost

0083.50

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

MAIN 1

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0037

B1

Date(mm/dd/yyyy):
Speed

40

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

MTH

Description
VEGETATION OBSTRUCTS VISIBILITY OF RAILROAD SIGN. ( NORTH SIDE OF TRACK, BUSHES IN FRONT OF WB CROSSING (X) SIGN )
Seal Applied

Seal Removed

Violation Recommended

Yes

No

Required

Optional

Written Notification to

FRA of Remedial Action is:

Hazard Class

Latitude:
Railroad Action Code

Source Code File Number

UN/NA ID

Longitude:
Date(mm/dd/yyyy):

Comments on back?

ID's of Accompanying
Inspector(s)

R8CORTEX

Page
FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs

FRA COPY

of

**RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences

DEPARTMENT OF TRANSPORTATION

INSPECTION REPORT

FEDERAL RAILROAD ADMINISTRATION (FRA)


Inspector's ID No.

Report No.

00417
Item

28

Initials/Milepost

0077.33

OMB Approval No.:

(Continuation)

2130-0509

Report Date

4/27/2016

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

213

Defect

Subrule

0135

B1

Speed

60

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
IMPROPER FIT BETWEEN SWITCH POINT AND STOCK RAIL. ( RIGHT HAND SIDE POINT GAP, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

Initials/Milepost

0070.79

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Date(mm/dd/yyyy):

Defect

Subrule

Speed

0133

A12

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE FROG BOLTS. ( CPS 071, CARRIAGE BOLTS, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

Initials/Milepost

0069.44

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Date(mm/dd/yyyy):

Defect

Subrule

Speed

0133

A13

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE GUARD RAIL BOLTS. ( CPS 069, CARRIAGE BOLTS, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

10

Initials/Milepost

0064.92

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0037

E3

Date(mm/dd/yyyy):
Speed

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

MTH

Description
VEGETATION BRUSHING SIDES OF ROLLING STOCK ( TREE ON SOUTH SIDE OF TRACK )
Seal Applied

Seal Removed

Violation Recommended

Yes

No

Required

Optional

Written Notification to

FRA of Remedial Action is:

Hazard Class

Latitude:
Railroad Action Code

Source Code File Number

UN/NA ID

Longitude:
Date(mm/dd/yyyy):

Comments on back?

ID's of Accompanying
Inspector(s)

R8CORTEX

Page
FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs

FRA COPY

of

**RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences

DEPARTMENT OF TRANSPORTATION

INSPECTION REPORT

FEDERAL RAILROAD ADMINISTRATION (FRA)


Inspector's ID No.

Report No.

00417
Item

11

28

Initials/Milepost

0063.08

OMB Approval No.:

(Continuation)

2130-0509

Report Date

4/27/2016

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

213

Defect

Subrule

0133

A9

Speed

60

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE ADJUSTABLE RAIL BRACES. ( E. HOOD RIVER, LEFT HAND SIDE # 5 BRACE, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

12

Initials/Milepost

0063.08

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Date(mm/dd/yyyy):

Defect

Subrule

Speed

0133

A12

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE FROG BOLTS. ( CARRIAGE BOLTS, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

13

Initials/Milepost

0063.08

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0139

Date(mm/dd/yyyy):
Speed

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
EXCESSIVE CLEARANCE BETWEEN HOLD-DOWN HOUSING AND HORN. ( MEASURES 5/16 OF INCH, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

14

Initials/Milepost

0062.24

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0133

A9

Date(mm/dd/yyyy):
Speed

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE ADJUSTABLE RAIL BRACES. ( W. HOOD RIVER, LEFT HAND SIDE #3 BRACE, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Yes

No

Required

Optional

Written Notification to

FRA of Remedial Action is:

Hazard Class

Latitude:
Railroad Action Code

Source Code File Number

UN/NA ID

Longitude:
Date(mm/dd/yyyy):

Comments on back?

ID's of Accompanying
Inspector(s)

R8CORTEX

Page
FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs

FRA COPY

of

**RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences

DEPARTMENT OF TRANSPORTATION

INSPECTION REPORT

FEDERAL RAILROAD ADMINISTRATION (FRA)


Inspector's ID No.

Report No.

00417
Item

15

28

Initials/Milepost

0062.24

OMB Approval No.:

(Continuation)

2130-0509

Report Date

4/27/2016

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

213

Defect

Subrule

Speed

0133

A15

60

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
TURNOUT FASTENINGS NOT INTACT. ( LEFT HAND GUARD RAIL, MARKED WITH SURVEYOR TAPE, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

16

Initials/Milepost

0059.40

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0133

A9

Date(mm/dd/yyyy):
Speed

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE ADJUSTABLE RAIL BRACES. ( CPS 059, LEFT HAND SIDE #3 BRACE, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

17

Initials/Milepost

0059.40

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0133

A6

Date(mm/dd/yyyy):
Speed

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE SWITCH ROD BOLTS. ( #2 SWITCH ROD, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

18

Initials/Milepost

0059.40

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Date(mm/dd/yyyy):

Defect

Subrule

Speed

0133

A15

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
TURNOUT FASTENINGS NOT INTACT. ( HORN BOLT LOOSE, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Yes

No

Required

Optional

Written Notification to

FRA of Remedial Action is:

Hazard Class

Latitude:
Railroad Action Code

Source Code File Number

UN/NA ID

Longitude:
Date(mm/dd/yyyy):

Comments on back?

ID's of Accompanying
Inspector(s)

R8CORTEX

Page
FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs

FRA COPY

of

**RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences

DEPARTMENT OF TRANSPORTATION

INSPECTION REPORT

FEDERAL RAILROAD ADMINISTRATION (FRA)


Inspector's ID No.

Report No.

00417
Item

19

28

Initials/Milepost

0057.35

OMB Approval No.:

(Continuation)

2130-0509

Report Date

4/27/2016

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

213

Defect

Subrule

0133

A9

Speed

60

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE ADJUSTABLE RAIL BRACES. ( CPS 057, RIGHT HAND SIDE #7 BRACE, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

20

Initials/Milepost

0057.35

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0133

A7

Date(mm/dd/yyyy):
Speed

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
MISSING COTTER PINS. ( HORN BOLTS, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

21

Initials/Milepost

0051.74

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0133

A9

Date(mm/dd/yyyy):
Speed

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE ADJUSTABLE RAIL BRACES. ( CPS 052, RIGHT HAND SIDE #5 BRACE, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

22

Initials/Milepost

0051.74

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0133

A7

Date(mm/dd/yyyy):
Speed

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
MISSING COTTER PINS. ( LEFT HAND SWITCH ROD BOLT, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Yes

No

Required

Optional

Written Notification to

FRA of Remedial Action is:

Hazard Class

Latitude:
Railroad Action Code

Source Code File Number

UN/NA ID

Longitude:
Date(mm/dd/yyyy):

Comments on back?

ID's of Accompanying
Inspector(s)

R8CORTEX

Page
FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs

FRA COPY

of

**RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences

DEPARTMENT OF TRANSPORTATION

INSPECTION REPORT

FEDERAL RAILROAD ADMINISTRATION (FRA)


Inspector's ID No.

Report No.

00417
Item

23

28

Initials/Milepost

0051.74

OMB Approval No.:

(Continuation)

2130-0509

Report Date

4/27/2016

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

213

Defect

Subrule

Speed

0133

A15

60

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
TURNOUT FASTENINGS NOT INTACT. ( HORN BOLT LOOSE, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

24

Initials/Milepost

0049.17

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Date(mm/dd/yyyy):

Defect

Subrule

Speed

0133

A12

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE FROG BOLTS. ( CPS 050, CARRIAGE BOLTS, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

25

Initials/Milepost

0049.17

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0133

A7

Date(mm/dd/yyyy):
Speed

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
MISSING COTTER PINS. ( FROG CARRIAGE BOLTS, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

26

Initials/Milepost

0043.44

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0133

A9

Date(mm/dd/yyyy):
Speed

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE ADJUSTABLE RAIL BRACES. ( CPS 043, RIGHT HAND SIDE GAGE PLATE, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Yes

No

Required

Optional

Written Notification to

FRA of Remedial Action is:

Hazard Class

Latitude:
Railroad Action Code

Source Code File Number

UN/NA ID

Longitude:
Date(mm/dd/yyyy):

Comments on back?

ID's of Accompanying
Inspector(s)

R8CORTEX

Page
FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs

FRA COPY

of

**RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences

DEPARTMENT OF TRANSPORTATION

INSPECTION REPORT

FEDERAL RAILROAD ADMINISTRATION (FRA)


Inspector's ID No.

Report No.

00417
Item

27

28

Initials/Milepost

0043.44

OMB Approval No.:

(Continuation)

2130-0509

Report Date

4/27/2016

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

213

Defect

Subrule

0133

A7

Speed

Class Train #/Site

60

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
MISSING COTTER PINS. ( RIGHT HAND SIDE CLIP BOLT, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

28

Initials/Milepost

0043.44

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0133

A2

Date(mm/dd/yyyy):
Speed

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE CLIP BOLT ( LEFT HAND SIDE #3 ROD, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

29

Initials/Milepost

0042.04

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Date(mm/dd/yyyy):

Defect

Subrule

Speed

0133

A14

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
LOOSE GUARD RAIL CLAMPS ( CPS 041, 3 ON LEFT HAND GUARD RAIL, MARKED WITH SURVEYOR TAPE )
Seal Applied

Seal Removed

Violation Recommended

Hazard Class

Latitude:

Yes

No

Required

Optional

Written Notification to

Item

30

Initials/Milepost

0049.17

Longitude:

Railroad Action Code

FRA of Remedial Action is:

Equipment/Track #

SIMN

Type/Kind 49 CFR/
USC

UN/NA ID

213

Defect

Subrule

0127

Date(mm/dd/yyyy):
Speed

60

Comments on back?

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

TOM

Description
FAILURE OF FASTENING COMPONENTS TO EFFECTIVELY MAINTAIN GAGE ( LAGS ALLOW LATERAL MOVEMENT, MARKED WITH SURVEYOR
TAPE )
Seal Applied

Seal Removed

Violation Recommended

Yes

No

Required

Optional

Written Notification to

FRA of Remedial Action is:

Hazard Class

Latitude:
Railroad Action Code

Source Code File Number

UN/NA ID

Longitude:
Date(mm/dd/yyyy):

Comments on back?

ID's of Accompanying
Inspector(s)

R8CORTEX

Page
FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs

FRA COPY

of

**RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences

DEPARTMENT OF TRANSPORTATION
FEDERAL RAILROAD ADMINISTRATION (FRA)
Inspector's ID No.

Report No.

00417
Item

28

Initials/Milepost

INSPECTION REPORT

OMB Approval No.:

(Continuation)

2130-0509

Report Date

4/27/2016

Equipment/Track #

Type/Kind 49 CFR/
USC

Defect

Subrule

Speed

Class Train #/Site

SNFR* RCL** # of
Activity
Occ.*** Code

31

Description - [** Comment to Railroad/Company **]


THIS INSPECTION ENCOMPASSED THE MAIN TRACK AND TURNOUTS FROM THE DALLES TO CASCADE LOCKS.
I WAS ACCOMPANIED DURING THIS INSPECTION BY UNION PACIFIC RAILROAD REPRESENTATIVES, PETE VALLEJO, JOE JOHNSTON AND
CRAIG MERRILL.
Seal Applied

Seal Removed

Violation Recommended

Yes

No

Required

Optional

Written Notification to

FRA of Remedial Action is:

Hazard Class

Latitude:
Railroad Action Code

Source Code File Number

UN/NA ID

Longitude:
Date(mm/dd/yyyy):

Comments on back?

ID's of Accompanying
Inspector(s)

R8CORTEX

Page
FORM FRA F 6180.96 (Revised 07/14) *SNFR-Special Notice for Repairs

FRA COPY

of

**RCL-Remote Control Locomotive ***# of Occ.-Number of Occurrences