You are on page 1of 32

Distribution System

MCBs, RCCBs, Distribution Boards

Keeping you protected

Warranty Policy :
Product offered by us are warranted against defects arising out of manufacturing processes or use of defective raw materials, for a period of
18 months from the date of supply or 12 months from the date of installation whichever is earlier. The company reserves the right to either replace
or repair the defective items after ascertaining the facts through a detailed service report on usage of our products in normal conditions. However,
MCB warranty is 3 years as standard and extends to 5 years in case used in GE make standard distribution boards.
The prices mentioned in the buylog for the same are for guidance purposes only. The products may be sold at lower prices also. Goods are always
sold subject to laws, rules and regulations relating to excise, customs and maximum retail price as applicable at the time of purchase and as printed
on the goods. Excise duty is not applicable on Guardline MCB, however applicable on RCCBs and DBs.

About GE Energy - Industrial Solutions

GE Energy - Industrial Solutions, India offers innovative


solutions to meet customer needs in Power & Protection.
The company has a pan India presence, with 4 regional
offices, 9 branch offices and one manufacturing plant.
GE Energy, offers solutions to customers in several segments
that include power sector, core infrastructure like marine
establishments, airports, highways, heavy & light industries,
IT & ITES infrastructure, healthcare, commercial and
residential segments.

Contents
A6

Guardline
Miniature Circuit Breakers

B10

Safetrip
Residual Current Circuit Breakers

C14

Safeline
Distribution Boards
Dimensions & Diagrams

Guardline
Miniature Circuit Breakers

Keeping you guarded

Salient Features

Technical Details

Conforms to IS8828:96/IEC60898-1

0.5A to 63A, 10kA

Rated Current(In)

0.5A, 1A, 2A, 3A, 4A, 6A, 10A, 16A,


20A, 25A, 32A, 40A, 50A, 63A

Trip free mechanism

Number of Poles

1 Pole, 2 Pole, 3 Pole and 4 Pole

Disconnection with positive contact

Breaking Capacity

10kA

Low watt loss Energy saving

Rated Voltage

240/415V AC

Touch proof terminals IP20

Insulation Voltage

500V AC

High grade engineering plastic housing

Frequency

50/60Hz

ON-OFF flag indication

Tripping Characteristics* :

C, D

Captive terminal screws

Operating Temp Range

-250C to +550C

Compatibility with all DBs

Mounting Arrangement

Snap on fixing, 35mm DIN Channel

Isolators

40/63A in 2 Pole, 3 Pole and 4 Pole


Higher ratings on request

*B series on request

Tripping Characterstics Curve


Type - B, C & D
10000
5000
3600

Limit Specified in

IS: 8828-1996/IEC-60898-1-2002

Lower Limit as per Standard

In : Rated Current
B Type - 0.5A to 63A
C Type - 0.5A to 63A
D Type - 0.5A to 63A

Upper Limit as per Standard

1000

Reference Calibration Temp. 40 C


o

Time in Seconds

100

10

-B-Type-

-C-Type-

-D-Type-

0.1

0.01

1 1.13 1.45

2 2.55 3

10

14

20

28

50

Multiple of Rated Current

A7

Guardline Ordering Codes


Current Rating
(A)

Ordering Cat.No.
Type C

Ordering Cat.No.
Type D

Standard
Pack Qty

0.5

GLCSP00

GLDSP00

12

GLCSP01

GLDSP01

12

GLCSP02

GLDSP02

12

GLCSP03

GLDSP03

12

GLCSP04

GLDSP04

12

Single Pole

GLCSP06

GLDSP06

12

10

GLCSP10

GLDSP10

12

16

GLCSP16

GLDSP16

12

20

GLCSP20

GLDSP20

12

25

GLCSP25

GLDSP25

12

32

GLCSP32

GLDSP32

12

40

GLCSP40

GLDSP40

12

50

GLCSP50

GLDSP50

12

63

GLCSP63

GLDSP63

12

0.5

GLCDP00

GLDDP00

GLCDP01

GLDDP01

GLCDP02

GLDDP02

GLCDP03

GLDDP03

GLCDP04

GLDDP04

GLCDP06

GLDDP06

10

GLCDP10

GLDDP10

16

GLCDP16

GLDDP16

20

GLCDP20

GLDDP20

25

GLCDP25

GLDDP25

32

GLCDP32

GLDDP32

40

GLCDP40

GLDDP40

50

GLCDP50

GLDDP50

63

GLCDP63

GLDDP63

0.5

GLCTP00

GLDTP00

GLCTP01

GLDTP01

GLCTP02

GLDTP02

GLCTP03

GLDTP03

Double Pole

Triple Pole

A8

Current Rating
(A)

4
6
10
16
20
25
32
40
50
63
Four Pole
0.5
1
2
3
4
6
10
16
20
25
32
40
50
63

Ordering Cat.No.
Type C

Ordering Cat.No.
Type D

Standard
Pack Qty

GLCTP04
GLCTP06
GLCTP10
GLCTP16
GLCTP20
GLCTP25
GLCTP32
GLCTP40
GLCTP50
GLCTP63

GLDTP04
GLDTP06
GLDTP10
GLDTP16
GLDTP20
GLDTP25
GLDTP32
GLDTP40
GLDTP50
GLDTP63

4
4
4
4
4
4
4
4
4
4

GLCFP00
GLCFP01
GLCFP02
GLCFP03
GLCFP04
GLCFP06
GLCFP10
GLCFP16
GLCFP20
GLCFP25
GLCFP32
GLCFP40
GLCFP50
GLCFP63

GLDFP00
GLDFP01
GLDFP02
GLDFP03
GLDFP04
GLDFP06
GLDFP10
GLDFP16
GLDFP20
GLDFP25
GLDFP32
GLDFP40
GLDFP50
GLDFP63

3
3
3
3
3
3
3
3
3
3
3
3
3
3

Isolator

For

Current Rating

Poles

Ordering Cat.No.

40
63
40
63
40
63

Double Pole
Double Pole
Triple Pole
Triple Pole
Four Pole
Four Pole

GLISDP40
GLISDP63
GLISTP40
GLISTP63
GLISFP40
GLISFP63

marked MCBs please contact your nearest GE sales office

A9

Safetrip
Residual Current Circuit Breakers

Keeping you safe

Salient Features

Technical Details

Conforms to IEC61008-1

Rated Current(In)

25A, 40A, 63A

2 Pole & 4 Pole

Sensitivity*

30mA, 100mA, 300mA

Trip free mechanism

Number of Poles

2 Pole and 4 Pole

Disconnection with positive contact

Rated Voltage

240/415V AC

Antiwelding contacts

Insulation Voltage

500V AC

Bi-connect facility

Frequency

50/60Hz

Touch proof terminals IP20

Operating Temp. Range

-250C to +600C

Resistance against unwanted tripping

Terminal Capacity

25mm2

Test facility - A test button T provided on device

Mounting Arrangement

35mm DIN Channel

No ageing effect

Service Life

20000 operations

Compatibility with all DBs

Optional Accessories

Aux. contact, shunt & undervoltage


release, motor operator & panel
board switch

Protection
Personal protection - Against electrocution

*500mA sensitivity available on request for industrial applications

The use of exposed, substandard and poorly wired, or damaged


equipment reduces the safety of an installation and increases the
risk of an electric shock to the person in contact. Electrocution is a
passage of current flowing through human body which affects
the vital functioning like breathing and heartbeat. This can be very
dangerous to the person in contact depending upon current and
time for which it flows.
A correctly selected RCCB can detect even small currents flowing
to earth and reduces the risk of electrocution. The effect of electric
current through human body has been well researched and is as
below.
500mA

Immediate cardiac arrest resulting in death

70-100mA

Cardiac fibrillation; the heart begins to


vibrate and no longer beats at a steady rate
This situation is dangerous since it is
irreversible

20-30mA

Muscle contraction can cause respiratory

10mA

paralysis
Muscle contraction: the person remains stuck to
the conductor

1-10mA

Prickling sensations

B11

However, electrocution should not be viewed in terms of current alone but in


terms of contact voltage. A person gets electrocuted by coming in contact
with an object that has a different potential from his/her own. The difference in
potential causes the current to flow through the body.
The human body has known limits:

In a dry environment, voltage limit = 50V

In a humid environment, voltage limit = 25V

Against Indirect Contact

Zone

Physiological effects

Over current protection devices like MCB are unable to act


promptly on small earth leakage currents. To comply with wiring
regulations the earth fault loop impedance in Ohms, multiplied
by the rated tripping current of the RCD in amperes must not
exceed 50.

Usually has no reactions or effects.

Usually has no harmful effects.

Usually, no organic damage is expected.


Here the likelihood present is of muscular contractions
and difficulty in breathing. Reversible disturbances in
the formation and conductance of impulses in the

Against Fire

heart, including arterial fibrillation and transient

The majority of fires in an electrical installation are result of

cardiac arrest without ventricular fibrillation are

leakage current flowing to earth and even a current of the order

possible. These effects increase with current

of 1A can lead to big fire. These type of faults are not detected by

magnitude and time.

the normal short circuit protection device like MCB or Fuse. A


correctly selected RCCB will detect this leakage and save the risk
of fire saving the installation.

In addition to the effects of Zone 3, the probability of


ventricular fibrillation increases from 5% (curve c2),
to about 50% (curve c3) and beyond 50% above
(curve c3). Increasing with magnitude and time are
pathophysiological effects as cardiac and breathing
arrest, whilst heavy burns are possible.

B12

Selection
30mA - This RCCB will provide a high degree of protection against

100mA - This RCCB will normally give high degree of protection

electrocution. The current flowing through human body depends

against electrocution but there is a possibility that the shock

upon the resistance of human body and voltage across it and can

current could fall below the tripping level of RCCB. This could occur

vary between 80mA to 240mA. To be within zone of the IEC curve

if additional resistances to that of human body are included in the

as shown in chart. It is necessary for the RCCB to operate within

earth path. The 100mA RCCB protects against leakage currents

50ms at 240mA and 150ms at 80mA. Both these conditions are

and indirect contact with earth loop impedance upto 500 Ohms.

satisfied by 30mA RCCB. For households, individual loads, damp


areas and construction installations, RCCB with sensitivity not
exceeding 30mA is recommended.

300mA - This RCCB may be used where only fire protection is


required. eg., on lighting circuits and larger installations. These will
not give any protection against electrocution.

Safetrip RCCB offering


Rating at 240V/415V AC
Amps

Rating at 240V AC

Poles

Sensitivity (mA)

Poles

Sensitivity (mA)

25

30

30

40

30

30

63

30

30

25

100

100

40

100

100

63

100

100

25

300

300

40

300

300

63

300

300

B13

Safeline
Distribution Boards

Keeping you secure

Salient Features

Technical Details
Voltage

240V AC for SPN, 415V for


TP/TPN DBs

SPN, TPN in single & double door

Standard Busbar Rating

63A/100A/125A

Degree of protection IP30, IP42 & IP43

No. of Ways

4, 6, 8, 10, 12, 14, 18 ways

Surface & flush mounting

Mounting

Surface/Flush

Powder coated Corrosion & scratch resistance

Dielectric Strength

2.5kV RMS AC for 1min

Detachable gland plate

Mounting Arrangement

35mm DIN Rail for MCBs, RCCBs

Adequate knock-outs on all sides

Generous wiring space

Clear circuit identification

Supplied complete with bus bars, earth & neutral bars

Multitier, phase segregated, 7 segments, vertical DBs

Plug & sockets boards

Prewired DBs available on request Please contact your nearest GE Sales Office

Aesthetically designed in compliance with latest standards

Wide range-sheet steel DBs upto 18 ways

C15

One Way Enclosures


Salient Features

Plane enclosures

1, 2, 3, 4, 5, 6, 8 ways

IP30 pole incomer

Dimensions & Diagram - 1.1 | Page D28


One Way Enclosures

Technical Details
Description
1Way
2Way
3Way
4Way
6Way
8Way
Blanking Plate
1Way

C16

Single Door
Code Ref.
SLEMS0001Y
SLEMS0002Y
SLEMS0003Y
SLEMS0004Y
SLEMS0006Y
SLEMS0008Y
SLMBP0001X

SPN Distribution Boards


Salient Features
Safe line - Sheet steel - SPN

SPN version in 4, 6, 8, 10, 12, 14, 16 and 18 ways outgoing

Single door, double door and acrylic door

IP30, IP42 and IP43 protection

Liberal wiring space, adequate cable glands

Superior powder coated finish for better protection against heat


& dust (Powder coating thickness of more than 60 microns)

Detachable gland plates

Complete with phase busbars, earthbars, neutral bars & cable kit

Dimensions & Diagram - 1.2 | Page D28


SPN Distribution Boards

Technical Details
Description
4Way
6Way
8Way
10Way
12Way
14Way
16Way
18Way

Single Door

Double Door

Acrylic Door

Code Ref.

Code Ref.

Code Ref.

SLSMS0204Y
SLSMS0206Y
SLSMS0208Y
SLSMS0210Y
SLSMS0212Y
SLSMS0214Y
SLSMS0216Y
SLSMS0218Y

SLSMD0204Y
SLSMD0206Y
SLSMD0208Y
SLSMD0210Y
SLSMD0212Y
SLSMD0214Y
SLSMD0216Y
SLSMD0218Y

SLSMA0206Y
SLSMA0208Y
SLSMA0210Y
SLSMA0212Y
SLSMA0214Y
SLSMA0216Y
SLSMA0218Y0

Dimensions

C17

TPN Distribution Boards


Salient Features

4, 6, 8 and 12 ways

Single door, double door and acrylic door (IP30, IP42 and IP43)

With provision 8 module incomer and SP MCB as outgoing

With copper busbar, neutral link, earth link

Supplied with wire set

Dimensions & Diagram - 1.3 | Page D28


TPN Distribution Boards

Technical Details
Description
4Way
6Way
8Way
12Way

C18

Single Door
Code Ref.
SLTMS0804Y
SLTMS0806Y
SLTMS0808Y
SLTMS0812Y

Double Door

Acrylic Door

Code Ref.

Code Ref.

SLTMD0804Y
SLTMD0806Y
SLTMD0808Y
SLTMD0812Y

SLTMA0804Y
SLTMA0806Y
SLTMA0808Y
SLTMA0812Y

Per Phase Isolation


Horizontal Distribution Boards
Salient Features

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

With copper bus bar

Suitable for 8 module incomer and DP RCCB/RCBO as


sub incomer and SP MCBs as outgoing

3 separate mutual link for each phase

With neutral link and earth bar

6, 8, 12, 16 ways

Dimensions & Diagram - 1.4 | Page D28


Per Phase Isolation Horizontal Distribution Boards

Technical Details :

With four neutral links, one earth link, excluding bus bars and interconnections

Description
6Way 8+4+2
8Way 8+6+2
12Way 8+10+2
16Way 8+14+2

Single Door
Code Ref.
SLHMS0806Y
SLHMS0808Y
SLHMS0812Y
SLHMS0816Y

Double Door
Code Ref.
SLHMD0806Y
SLHMD0808Y
SLHMD0812Y
SLHMD0816Y

C19

Per Phase Isolation


Vertical Distribution Boards
Salient Features

IP30, IP42 and IP43 protection

With 8 cutting incomer and 3 rows with different


configuration

Separate neutral for each phase

SP and TP outgoing are possible

Sub incomer of 2 Pole

Dimensions & Diagram - 1.5 | Page D29


Per Phase Isolation Vertical Distribution Boards

Technical Details :

With four neutral links, one earth link, excluding bus bars and interconnections.

Description
8 Way (3 Rowx8+1 Rowx8)
10 Way (3 Rowx10+1 Rowx8)
12 Way (3 Rowx12+1 Rowx8)
14 Way (3 Rowx14+1 Rowx8)
16 Way (3 Rowx16+1 Rowx8)

C20

Double Door

Acrylic Door

Code Ref.

Code Ref.

SLIMD0808Y
SLIMD0810Y
Single Door
SLIMD0812Y
SLIMD0814Y
SLIMD0816Y

SLIMA0808Y
SLIMA0810Y
SLIMA0812Y
SLIMA0814Y
SLIMA0816Y

TPN Vertical Distribution Boards


Salient Features

IP30, IP42 and IP43 protection

With MCB and 49 RCCB incomer (4 Pole)

TP and SP outgoing

IP30 and IP43

With copper bus bar

Spectra range MCCB upto 125A and Record range for


higher rating

Dimensions & Diagram - 1.6 | Page D29


TPN Vertical Distribution Boards

Technical Details - Provision for 4Pole MCB/RCCB


Description
4Way
6Way
8Way
12Way

Single Door

Double Door

Acrylic Door

Code Ref.

Code Ref.

Code Ref.

SLVMD0804Y
SLVMD0806Y
SLVMD0808Y
SLVMD0812Y

SLVMA0804Y
SLVMA0806Y
SLVMA0808Y
SLVMA0812Y

SLVMS0804Y
SLVMS0806Y
SLVMS0808Y
SLVMS0812Y

C21

TPN Vertical Distribution Boards


with MCCB Incomer
Salient Features

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

With copper bus bar

With neutral bar and earth bar

Pan assembly for ease of installation

With provisions for Spectra / Record Range MCCB


as incomer and SP/TP MCBs as outgoing

4, 6, 8 and 12 ways

Dimensions & Diagram - 1.7 | Page D29


TPN Vertical Distribution Boards with MCCB Incomer

Technical Details - Provision for 4Pole MCB/RCCB


Description
4Way
6Way
8Way
12Way

C22

Double Door - 100A

Double Door - 225A

Code Ref.

Code Ref.

SLVMDM04Y
SLVMDM06Y
SLVMDM08Y
SLVMDM12Y

SLVMDM204Y
SLVMDM206Y
SLVMDM208Y
SLVMDM212Y

Phase Selector Distribution Boards


Salient Features

With provision for 3nos. phase selector switches and in-built


piano switches

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

With copper bus bar

With neutral bar, earth bar, and wire set

With provision for 8 module incomer and SP MCB, as outgoing

4, 6, 8 and 12 ways

Dimensions & Diagram - 1.8 | Page D29


Phase Selector Distribution Boards

Technical Details - TPN phase selector DB with 3nos. piano switch


Description
4Way
6Way
8Way
12Way

Single Door

Double Door

Code Ref.

Code Ref.

SLXMS0804Y
SLXMS0806Y
SLXMS0808Y
SLXMS0812Y

SLXMD0804Y
SLXMD0806Y
SLXMD0808Y
SLXMD0812Y

C23

Phase Segregated Distribution Boards


Salient Features

DB with phase segregation and separator between incomer


and outgoing

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

With copper bus bar

With neutral bar, earth bar

With provision for 8 module incomer and DP RCCB/RCBO as


sub incomer and SP MCB, as outgoing

4, 6, 8 and 12 ways

Dimensions & Diagram - 1.9 | Page D30


Phase Segregated Distribution Boards

Technical Details - Compartmental space for 4P MCB


Description
4Way
6Way
8Way
12Way

C24

Single Door

Double Door

Code Ref.

Code Ref.

SLCMS0804Y
SLCMS0806Y
SLCMS0808Y
SLCMS0812Y

SLCMD0804Y
SLCMD0806Y
SLCMD0808Y
SLCMD0812Y

Universal Distribution Boards


Salient Features

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

Flexibility to organize the distribution as per site requirements

With neutral bar and earth bar

26, 28, 39, 42, 52, 56 ways in 2, 3 and 4 rows

Other configurations on request

Dimensions & Diagram - 1.10 | Page D30


Universal Distribution Boards

Technical Details
Description
13module x 2 tier
13module x 3 tier
13module x 4 tier
14module x 2 tier
14module x 3 tier
14module x 4 tier

Double Door
Code Ref.
SLFMD0213Y
SLFMD0313Y
SLFMD0413Y
SLFMD0214Y
SLFMD0314Y
SLFMD0414Y

Acrylic Door
Code Ref.
SLFMA0213Y
SLFMA0313Y
SLFMA0413Y
SLFMA0214Y
SLFMA0314Y
SLFMA0414Y

C25

Plug & Socket Boards


Salient Features

SPN and TPN Distribution Boards

With in-built plug and socket

Ideal for protection of appliances like ACs, Geysers etc.

Available from 20A SPN to 63A TPN

Available for DP RCCB incomer

Excellent aesthetics

Dimensions & Diagram - 1.11 | Page D30


Plug & Socket Boards

Technical Details
Description
20A SPN
20A TPN
32A TPN
20A with provision for DP RCCB
32A TP with provision for 4P RCCB
63A TP with provision for 3P MCB

C26

Single Door
Code Ref.
SLRMS0S20Y
SLRMS0T20Y
SLRMS0T32Y
SLRMS0220Y
SLRMS0432Y
SLRMS0363Y

Dimensions & Diagram


Please contact your nearest GE sales office for drawings in printable format

Dimensions & Diagram - 1.4


Per Phase Isolation Horizontal Distribution Boards

D28

340

450

470

225

Dimensions & Diagram - 1.2


SPN Distribution Boards

105

Dimensions & Diagram - 1.3


TPN Distribution Boards

245

Dimensions & Diagram - 1.1


One Way Enclosures

Dimensions & Diagram - 1.5


Per Phase Isolation Vertical Distribution Boards

Dimensions & Diagram - 1.7


TPN Vertical Distribution Boards with MCCB Incomer

Dimensions & Diagram - 1.6


TPN Vertical Distribution Boards

Dimensions & Diagram - 1.8


Phase Selector Distribution Boards

D29

155

110

Dimensions & Diagram - 1.11


Plug & Socket Boards

168

Dimensions & Diagram - 1.9


Phase Segregated Distribution Boards

5
137

60

124

Dimensions:

78

Dimensions & Diagram - 1.10


Universal Distribution Boards

D30

168x137x60
275x135x65
275x135x65
235x180x65
275x180x65
317x140x127

Note :
Product upgradation is a continuous process. The data given is subject to change without any prior notice.
Please contact your nearest GE Sales office for the latest product information.

REGIONAL OFFICES

BRANCH OFFICES

NORTH
New Delhi

Chandigarh

Jaipur

Lucknow

GE India Industrial Pvt. Ltd.


71/1, Shivaji Marg
New Delhi-110015
Ph: (011) 45052277/8
Fax: (011) 25928088

GE India Industrial Pvt. Ltd.


SCO No. 72 & 73, First Floor
Sector 8/C, Madhya Marg
Chandigarh-160008
Ph: (0172) 3982908-10
Fax: (0172) 3982905

GE India Industrial Pvt. Ltd.


448, 4th Floor, Ganapati Plaza
M.I. Road, Jaipur-302001
Ph: (0141) 5112802
Fax: (0141) 2389012

GE India Industrial Pvt. Ltd.


101, Ace Business Center
19, Vidhan Sabha Marg
Lucknow-226001
Ph: (0522) 3203808, 3012444/666
Fax: (0522) 4045909

Bangalore

Chennai

Coimbatore

Cochin

Hyderabad

GE India Industrial Pvt. Ltd.


The Millenia, Level-6, Tower B
1 & 2, Murphy Road, Ulsoor
Bangalore-560008
Ph: (080) 41434000
Fax: (080) 41434199

GE India Industrial Pvt. Ltd.


Temple Tower, 6th Floor
476, (New No. 672) Anna Salai
Nandanam
Chennai-600035
Ph: (044) 45070470-84
Fax: (044) 45070474

GE India Industrial Pvt. Ltd.


No.36/6 & 7, 1st Floor
Ashirwad Building
D.B.Road, R.S. Puram
Coimbatore-641002
Ph: (0422) 4393520 / 4393529

GE India Industrial Pvt. Ltd.


Mayur Business Center & Motel
Chittur Road, Pullepadi Junction
Cochin-682035
Ph: (0484) 2364139
Fax: (0484) 4031400

GE India Industrial Pvt. Ltd.


5-2-45, Hyderbasti, RP Road
Near Gujarati High School
Secunderabad-500003
Ph: (040) 27543162, 66311264
Fax: (040) 66339272

SOUTH

Distribution System
MCBs, RCCBs, Distribution Boards

WEST
Mumbai

Ahmedabad

Pune

GE India Industrial Pvt. Ltd.


361/362, Solitaire Corporate Park
M. Vasanji Road, Chakala
Andheri (E), Mumbai-400093
Ph: (022) 40101610
Fax: (022) 40101611

GE India Industrial Pvt. Ltd.


405-406, Kirtiman Complex
Kinariwala House, Behind Citibank
Off C.G. Road, Ahmedabad-380006
Ph: (079) 65427385/55427389
Fax: (079) 26460637

GE Money Financial Services Limited


Shop No. 405-410, 4th Floor
City Point, Dhole Patil Road
Pune-411001
Mob: +91 9850867507

Keeping you protected

EAST
Kolkata
GE India Industrial Pvt. Ltd.
Horizon Building, 4th Floor
57, Chowringhee Road
Kolkata-700071
Ph: (033) 40034056
Fax: (033) 40034071

We are committed to continuous development and improvement of our products and the specifications are
subject to change without notice. For product availability and latest prices, please contact GE Sales Team.
For any further information, visit us at http://www.geindustrial.com

g and General Electric are registered trade marks of General Electric Co. USA

HO:
GE India Industrial Pvt. Ltd.
The Millenia, Level-6, Tower B
1 & 2, Murphy Road, Ulsoor
Bangalore-560008
Ph: (080) 41434000
Fax: (080) 41434199
Email: query@ge.com

Toll Free No:


18001024343
Customer Care:
gecustomer.care@ge.com

1107/MODGLMCB

Works:
GE India Industrial Pvt. Ltd.
Plot No. 42/1 & 45/14
Electronic City - Phase II
Bangalore-560100
Ph: (080) 41113000
Fax: (080) 28528469/552