You are on page 1of 15

Add lines as

needed

MS-71
2-8 Deg Cold Room

40.0
40.0
6.0

Occupancy, nos

2.8

Humidity, RH%
(approx)

2.1

Room Storage Temp, 0C

4.9

Temp sourrounding
cold room area, C

2.8

Ambient Temp, C

3.1

Insulation Thickness, mm

10.0

Insulation Type

Room Details

No.of Rooms

Height, m

Bulk Hold Cold Room

Width, m

MS-31

Length, m

Room Name / Item


Description

Sl No

COLD ROOM BASIC ENQUIRY SHEET

1
PUF
60
41
25
2-8
N/A
0

PUF
150
41
25
2-8
N/A
0

PUF
80
40
40
10

PUF
150

PUF
150

PUF
150

Design Cons

PUF

150

PUF

150

PUF

150

PUF

150

PUF

150

PUF

150

PUF

150

PUF

150

PUF

150

PUF

150

Total No. of rooms


Customer Name :
Site Location:
Person Requested :

Note:-

Insert extra rows if required.


Pls fill in the same format & dont change.

Add lines as
needed
Pull down time, hrs

Refrigerant

0.0
Liquid
3600.0
3600
40
6-8
R 404a

0
Liquid
200.0
200
40
6-8
R 404a

Tomato Pulp
2800.0
100
35
24
R 404a

Product Final
Temperature, 0C

Product entry
temperature, 0C

2-8 Deg Cold Room

Product Loading
(turnover) kG/day.

MS-71

Room Storage
capacity, Kg

Bulk Hold Cold Room

Product to be stored

MS-31

Machinary
(Motors,Packing
Machines etc.,), kW

Room Name / Item


Description

Sl No

COLD ROOM BASIC ENQUIRY SHEET


Room
Design
Details
Consideration Details

R 404a

R 404a

R 404a

R 404a

R 404a

R 404a

Customer Name :

Request Date

22-Nov-12

Site Location:
Person Requested :

Note:-

Insert extra rows if required.


Pls fill in the same format & dont change.

Rev

0.0

COLD ROOM BASIC ENQUIRY SHEET


Room Details

Out door unit type

Condenser Type

Standby Unit

Evaporator type

Evaporator MOC :
Casing / Coil / Fin.

Door Type

MS-31

Bulk Hold Cold Room

CDU

Air cooled

Built in Capacity

Ceiling Mount

PCGI/CU/Al

Swing

MS-71

2-8 Deg Cold Room

CDU

Air cooled

Built in Capacity

Ceiling Mount

PCGI/CU/Al

Swing

CDU

Air cooled

Not Required

Ceiling Mount

PCGI/CU/Al

Swing

CDU

Air cooled

Not Required

Ceiling Mount

PCGI/CU/Al

Swing

Sl No

Room Name / Item


Description

Add lines as
needed

IDU / ODU Details

CDU

Air cooled

Not Required

Ceiling Mount

PCGI/CU/Al

Swing

CDU

Air cooled

Not Required

Ceiling Mount

PCGI/CU/Al

Swing

CDU

Air cooled

Not Required

Ceiling Mount

PCGI/CU/Al

Swing

CDU

Air cooled

Not Required

Ceiling Mount

PCGI/CU/Al

Swing

CDU

Air cooled

Not Required

Ceiling Mount

PCGI/CU/Al

Swing

Customer Name :
Site Location:
Person Requested :

Note:-

Insert extra rows if required.


Pls fill in the same format & dont change.

COLD ROOM BASIC ENQUIRY SHEET


Remarks/Additionals

Panels

Room Name / Item


Description

Sl No

Add lines as
needed

Lay out Details

Room Details
Doors/Panels Details

MS-31

Bulk Hold Cold


No Room
Refrigerant but Chilled brine
Quote
( -5as
/ 0required
Deg C). AHU shall be
Attached
provided. The cold room shall be with Class D. 1250 CFM airflow

MS-71

2-8 Deg Cold Room

Quote as required

Conventional
Attached
cold storage with Chilled brine ceiling suspended evapoator

Quote as required

Not Available

Quote as required

Not Available

Quote as required

Not Available

Quote as required

Not Available

Quote as required

Not Available

Quote as required

Not Available

Quote as required

Not Available

Customer Name :
Site Location:
Person Requested :

Note:-

Insert extra rows if required.


Pls fill in the same format & dont change.

COLD ROOM BASIC ENQUIRY SHEET


Room Details

Room Name / Item


Description

Sl No

Add lines as
needed

/ 0 Deg C). AHU shall be provided.


MS-31
The
Bulkcold
Holdroom
Cold shall
Roombe with Class D. 1250 CFM airflow to be maitained in the room with terminal ceiling HEPA.
Conventional
MS-71
cold storage
2-8 Degwith
ColdChilled
Room brine ceiling suspended evapoator unit

Customer Name :
Site Location:
Person Requested :

Note:-

Insert extra rows if required.


Pls fill in the same format & dont change.