You are on page 1of 3

321136831.

xls
Design of Composite Columns to EC4
Column on Grid D/9 Ground to First Floor
Job Description Redditch
Job Number
10590
Length of column L =
Effective Length =
Aplied Axial Load =
Max Moment about Major axis Myy =
Max Moment about Minor axis Mzz =

7500
7500
7345
492
492

EC4 Clause

mm
mm
kN
kNm
kNm

Material Properties
Structural Steel

3.3

Nominal Steel Grade =


Nominal Yield Strength fy=
Modulus of Elasticity Ea=

50
345 N.mm2
205 kN/mm2

Concrete Class
Characteristic Strength fck=
Secant Modulus of elasticity s.t. Ecm=

40
40 N.mm2
35 kN/mm2

Concrete
3.1
3.1.4.1

Reinforcing steel
Type of steel
Characteristic strength fsk=
Modulus of elasticity Es=

460 N.mm2
205 kN/mm2

3.2.4

Partial Safety Factors


gamma a =
gamma c fundamental =
gamma c for effective elastic flex stiff =
gamma s =
Design Strengths
fyd=fy/gamma a =
fcd=alpha c*fck/gamma c =
fsd=fsk/gamma s =

1.05
1.5
1.35
1.15

Table 1

328.6 N.mm2
22.7 N.mm2
400.0 N.mm2

Check limits of acceptablility by hand


4.8.3.1(3)
Is column Doubly symmetrical
Is Concrete cover within limits
Is X-sect A of Longit Rebar>0.04Ac
Steel contribution factor Delta =
0.54 Section is within contribution limits
Steel Section Properties
Steel Section 305x305x158U.C.
Breadth of section - b =
310.6 mm
Depth of Section - h =
327.2 mm
Thickness of Web - tw =
13.8 mm
Thickness of flange - tf =
21.7 mm
X Sect Area - Aa =
20100 mm2
2nd Moment Area about Major Axis Iay
386900000 mm4
2nd Moment Area about Minor Axis Iaz
125000000 mm4
Plastic Modulus - Wpa.y
2675000 mm3

Waterman Group Confidential

06/14/2016

Page 1

321136831.xls
Plastic Modulus - Wpa.z

1225000 mm3
EC4 Clause

Reinforcement
Diameter of Bars =
Number of Bars =
Area of Reinforcement As=
Spacing of Reinforcement on Major =
Spacing of Reinforcement on Minor =
Concrete Area and Cover
Breadth of concrete Bz=
Depth of Concrete By=
Area of conrete Ac =
Cover Cz =
Cover Cy =

20
4
1257
430
430

mm
mm2
mm
mm

500 mm
500 mm
228643 mm2
94.7 Cover is Ok
86.4 Cover is Ok

As/Ac =
4% of concrete area (mm2) =

0.55% There is adequate reinforcement for model


9146 There is adequate reinforcement for model

Design Checks
Plastic Compression Resistance of Composite Cross-section

4.8.3.3

Npl.rd = Aa*fyd+Ac*fcd+As*fsd =

Eq 2

12290 kN

Evaluate the effective elastic flexural stiffnes of the


composite cross-section for short term loading
About the Major Axis
Ea*Iay =
Es*Isy =
0.8*Ecd*Icy =

79314500000 kNmm2
1.1908E+10 kNmm2
98795309618 kNmm2

Effective flexural Stiffness (EI)ey =


or
About the Minor Axis
Ea*Iaz =
Es*Isz =
0.8*Ecd*Icz =

1.9002E+11 kNmm2
1.9002E+05 kNm2

2.5625E+10
1.1908E+10
1.0423E+011

Effective flexural Stiffness (EI)ez =


or

1.4176E+11 kNmm2
1.4176E+05 kNm2

Evaluate the Non-Dimensional Slenderness Lambda


Npl.r =Aa*fy+Ac*0.85*fck+As*fsk=

15286 kN

Ncry = pi^2 * (EIey/l^2) =

33340 kN

Therefore Lambda y =

0.677

Ncrz = pi^2 * (EIez/l^2) =

24873 kN

Waterman Group Confidential

4.8.3.5(1)

06/14/2016

4.8.3.7

Page 2

321136831.xls

Therefore Lambda z =

0.784
EC4 Clause

Check resistance under Axial Compression


Major Axis
Phi =
Reduction Factor X =
Major Axis Compression Resistance =
Major axis has sufficient axial capacity
Minor Axis
Phi =
Reduction Factor X =
Minor Axis Compression Resistance =
Minor axis has sufficient axial capacity

0.810
0.796

4.8.3.8

9788 kN

4.8.3.8

0.950
0.672

4.8.3.8

8261 kN

4.8.3.8

Check for Second Order Effects


check for second order effects needed

Waterman Group Confidential

4.8.3.10
0.30

06/14/2016