SERIE UMC/E
Cooling and heating split systems
for comfort and process application
50 - 400 KW
Range overview
UMC/E = cooling only
UMC/E-HP = heat pump
The Bini Clima air cooled compact condensing units offer cooling capacities from 50-400 kW.
The UMC/E range is designed to be quiet, energy efficient and easy to install. Its at the forefront of market technology and specially developed for split system applications. Modular construction and improved range of options
ensure there is a unit for every application. The UMC/E range is ideally applicable to a variety of environments, from
large retail outlets to high tech environments and from process to comfort applications. All models offer the benefits
and reliability of multiple scroll compressor technology, in an efficient dual refrigeration circuit system providing two
or four stages of cooling for improved energy efficiency during part load conditions. The range includes the UMC/E
& UMC/E-HP models which are reversible for heat pump operation. The complete range is available with low noise,
super low noise, low ambient temperature and many other options, making the UMC/E series the most flexible on
the market.
Integrated Intelligent Controls allows efficient operating which can be integrated into a wide range of BMS systems
by using interface cards or gateways. Combine all this with modulating head pressure control and high efficiency
heat exchangers ensures the lowest possible life cycle costs.
Key features
50 to 400 kW Cooling capacity
18 unit sizes, wide range of options
Scroll compressor technology
R407C refrigerant as standard
R410A & R134a upon request
Key benefits
Energy Efficient split system
Suitable for most of AC applications
High quality and reliability
Easy to install and maintain
Quiet operation
Typical applications
Office buildings
Commercial centers
Airports
Data centers
Pharma industry
Certifications
ATEX
Typical installation
Standard features
Housing
The units are designed for outdoor installation. The unit housing is made from galvanized steel protected against
corrosion with an epoxy paint, color RAL 9010.
Upon request, the structure can be reinforced with anodized aluminum profiles, tightly secured to a strong base
frame to allow an easy lifting of the unit with hooks. The distribution of weight is uniform for an easy positioning on
site.
All electric and control devices are fitted into the electric panel fixed on the unit side and provided with a main switch.
Compressors
UMC/E & UMC/E-HP units are equipped with orbiting, rotary Scroll compressors. Thanks to the reduced quantity of
parts in motion and to the absence of suction/delivery valves, these compressors are extremely silent and are fit for
applications with low/average capacity.
Air Exchangers
Highly efficient condensing coils are made of copper tubes and mechanically expanded into aluminum fins.
Fans
Low noise and water proof axial type fans, protected with safety grid are used on the condensing coil side. Fan motors are directly coupled thus reducing vibrations and transmission failures. Motors are IP 54 and class F insulated
and are protected from voltage peaks with magneto-thermic switches installed into the electric panel placed on
machine side.
Unit Controller
Advanced digital controller allows intelligent control of compressors and fan as well as full communication to BMS
systems.
Standard options
4
5
9
10
11
12
Unit size
Cooling capacity
Power absorbed
E.E.R.
kW
kW
kW
50
49,6
14,6
3,4
60
57,3
16,4
3,5
65
65
18,8
3,4
Refrigerant
Compressors
Fans
120
97,6
27,8
3,5
123
35,1
3,5
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
kW
1,8
1,8
3,6
3,6
3,6
3,6
3,6
mm
rpm
m/s
C
800
900
4,2
800
900
4,84
800
900
5,48
800
900
8,29
800
900
10,43
dB(A)
67
67,5
67,5
71,5
71,5
71,5
72
2x12
2x22
2x12
2x22
2x16
2x28
2x16
2x28
+15 C
+45 C
2x16
2x28
2x22
2x35
2x22
2x35
Liquid Lime
Suction Lime
Min ambient temperature
Max ambient temperature
800
800
900
900
6,33
7,21
35
Turbolenced fins - Pipes striped inside
100
nr
nr
%
nr
Condensing coils
Sound pressure level at 1 m distance
in free field (ref. 2x 10-5)
85
85
24,4
3,5
Scroll
Type
Quantity
Cooling circuits
Partializing steps
Axial type
Nominal absorbed
power
Diameter
Revs
Total air flow
Ambient temperature
75
74,8
21,4
3,5
R407C
135
137,2
39,2
3,5
145
147,4
42,2
3,5
2
1
2
3
2
1
2
170
195
220
245
275
295
340
370
400
170
48,6
3,5
195
55,7
3,5
220
63,4
3,5
246
70,3
3,5
R407C
274,4
78,4
3,5
298,8
84,2
3,5
340
97
3,5
370
105,7
3,5
400
115
3,5
Scroll
2
2
2
3
2
2
2
4
2 Tandem
2
4
4
5,4
5,4
5,4
7,2
7,2
800
900
11,65
800
900
12,52
800
900
16,13
800
900
16,59
800
900
18,73
72
73
73
75
75
75
75
2x22
2x35
2x22
2x35
2x28
2x42
2x28
2x42
2x28
2x42
2x28
2x54
+15 C
+45 C
2x35
2x54
7,2
10,8
10,8
10,8
14,4
14,4
800
800
800
900
900
900
20,87
23,29
25,05
35
Turbolenced fins - Pipes striped inside
800
900
32,26
800
900
36,26
800
900
42,5
75
77
77
80
2x35
2x54
2x35
2x64
2x35
2x64
2x42
2x64
Heating pump
Electric data
50
60
65
75
85
100
120
Heating capacity
kW
66
73,7
83,8
96,2
109,4
125,4
158,1
Absorbed power
kW
14,6
16,4
16,8
21,4
24,4
22,8
35,1
Ambient temperature
Voltage 1
3ph/400V/50Hz
Nominal current 2
3,47
39,7
48,4
52,2
60,8
69,4
81,4
36,4
41,6
46,8
53,2
62,4
72,8
88,6
3,7
3,7
7,4
7,4
7,4
7,4
7,4
40,1
45,3
54,2
60,6
69,8
80,2
96
Starting current 4
149,2
194,2
202,9
204,8
294,1
298,4
339,4
61,7
67,7
77,4
77,4
87,4
123,4
127,4
145
170
195
220
245
275
295
340
370
400
176,4
189,8
218,6
250,9
284
316,3
352,8
379
437
425,7
515
39,2
42,2
48,5
55,7
63,4
70,3
76,4
84,2
97
105,7
115
7,0
3ph/400V/50Hz
94,3
100,5
135,9
160,4
162,8
192
219,8
234,6
221,8
320,8
345,8
98,8
106,2
124,8
145,6
148
177,2
197,6
212,4
249,6
220
293,6
11,1
11,1
11,1
14,8
14,8
14,8
22,2
22,2
22,2
29,6
29,6
109,9
117,3
135,9
160,4
162,8
192
219,8
234,6
274,8
299,6
323,2
402,7
405,8
351,2
367,8
414,8
420,8
497
506,3
580
630
695
151,1
151,1
171,1
246,8
210,8
254,8
302,2
302,2
350
350
420
Foundations
No special foundations are required, provided the supporting surface is flat and level, and can withstand the weight
or the unit. Installation of anti-vibration rubber pads is recommended to avoid transmission of vibrations to the building.
Clearances
For an optimal operation of the UMC/E condensing units, it is essential to respect the specified clearance around
the unit to ensure the proper air flow distribution through the condensers and allow an easy maintenance. Reduced
spaces may cause decrease of cooling capacity and loss of performances.
The space around the unit must be accurately respected to avoid air short circuits that may cause condensing
temperature raising.
The UMC/E condensing units must be easily accessible for periodic maintenance. Minimum suggested distance for
service from unit side is 1.000 mm.
If two or more units should be installed on the same site, a distance of 2.600 mm (minimum distance between two
condensing coils) must be respected to prevent recirculation of warm air.
The distance between the units and side walls must not be less than 2.100 mm. If the walls around the unit would
be higher than the unit sides, it s mandatory to respect a minimum distance of 2.600 mm.
1000
1000
10
1000
Unit
size
L
W
H
mm mm mm
50
60
65
75
85
100
120
135
145
170
195
220
245
276
295
340
370
400
1570
1570
2540
2540
2540
2540
2540
3510
3510
3510
2540
2540
2540
3510
3510
3510
4150
4150
1270
1270
1270
1270
1270
1270
1270
1270
1270
1270
2240
2240
2240
2240
2240
2240
2240
2240
2350
2350
2350
2350
2350
2350
2350
2350
2350
2350
2350
2350
2350
2350
2350
2350
2350
2350
Shipping
weight
(kg)
Operating
weight
(kg)
680
715
1005
1040
1075
1110
1145
1435
1470
1505
1795
1875
1955
2245
2325
2320
2490
2570
705
740
1030
1065
1125
1160
1195
1485
1520
1555
1845
1925
2005
2295
2375
2415
2550
2690
Product Specifications
11